COMBINATION INSTALLATIONS
Document # PGCI-024
Revised 02/03/11 Page 1/1
DRT Series Slide-in Cooktop
with ERV Series Slim Raised Vent
PLANNING
GUIDE
Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated.
3/8” min. (1.0 cm)
flat countertop
overhang required
behind cutout
Stiffener
warning
28 5/16” (71.9 cm)
Countertop
•
Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
•
All appliances must be installed in accordance with
the accompanying installation instructions.
DRT366 cooktop
3/8” min. (1.0 cm)
space behind
raised vent
chassis to clear
stiffener
Control panel
Cabinet face
Use Dacor raised
vent, model
ERV3615 only
Minimum
countertop
height:
30 1/4"
(76.8 cm)
DRT366S
ERV3615
■■
Use only approved raised vent model.
Model DRT304 is not approved for use with a raised
vent.
■■
Use only raised vent model specified. Raised vent
is not compatible with DRT cooktops having a serial
number starting with letters “SA.”
B - Cutout
Width
D
E
F - Raised
Vent Cutout
36”
(91.4 cm)
16 5/8”
(42.2 cm)
11 3/16”
(28.4 cm)
33 1/2”
(85.1 cm)
NOTE: Gas and electrical connections may only
be routed through the bottom of the cooktop when
installed with a raised vent.
Cabinet/Countertop Cutout Dimensions
with Raised Vent - side View
3/8” (1.0 cm) min.
countertop overhang
Approved Raised
Vent Model
IMPORTANT:
IMPORTANT: See raised vent
installation instructions for
duct system layout/planning
2 5/8”
(6.7 cm)
Model No.
Non combustible rear
wall recommended
10” (2.5 cm) min. to
combustible wall
above countertop,
both sides
F
Open to below to allow for raised
vent, gas and electrical connections
E
1” (2.5 cm) thick mounting platform min.
1/2” (1.3 cm)
countertop
overhang
Countertop
24 1/2”
15”
(62.2 cm) (38.1 cm)
Countertop
1/2” (1.3 cm)
countertop
overhang
Hole 1/2” dia. (1.3 cm),
2 places, through platform
for hold down bolts
2” (5.1 cm)
1” (2.5 cm)
D
D
CL
Cabinet face
below countertop
overhang
B
Cabinet/Countertop Cutout Dimensions with Raised Vent - Top View
Specifications subject to change without notice.
www.Dacor.com
Phone: (800) 793-0093
CI.10
Download PDF