Von Duprin PS914 Installation Instructions Manual
Von Duprin PS914 is a power supply designed for use with Von Duprin and Falcon EL devices. It provides 4 Amps DC @ 12/24 VDC and can be used to power these devices at 24VDC, 16A, 300ms. It features a 14” H x 12” W x 4” D enclosure with 8 knockouts for easy installation. The PS914 is UL 294, ULC-S318, RoHS, & FCC Part 15 compliant and compatible with various option boards such as 900-2RS, 900-2Q, 900-4R, 900-4RL, 900-8F, and 900-8P for expanded functionality.
PDF
Download
Document
Advertisement
Advertisement
Installation Instructions PS914 Power Supply 44487056 ! DANGER: To avoid risk of electric shock, turn off AC power before installing or servicing PS914 power supply. These instructions cover the following parts: : ING ! RN WA : ING RN ! WA ! GER DAN F1 ! DA ER NG : PS914 Power Supply Pages 1-3 900-KL Keylock (optional) Page 2 900-BB Battery Backup (optional) Page 3 900-2RS (optional) - Page 4 (2 Zone EL Control Individual/Sequential) PS914 Power Supply Specifications: Input 120/240 VAC, 1.4 A, 50/60Hz, High Voltage Class 1 Wiring Required Output 4 Amp DC @ 12/24 VDC May be used to power Von Duprin & Falcon EL device at 24VDC, 16A, 300ms Enclosure 14” H x 12” W x 4” D (8 knockouts, 1/2” or 3/4” ) Temperature Range 32°-120° F (0°- 49° C) Fuse F1, T6.3A 250 VAC ! CAUTION: For protection against risk of fire, replace fuse with same type and rating Compliance UL 294, ULC-S318, RoHS, & FCC Part 15, Class 2 Output Compatible Boards (Optional, 2 boards maximum) 900-2RS 900-2Q 900-4R 900-4RL 900-8F 900-8P INST. INSTRUCTIONS - 44487056 INST. INSTRUCTIONS - 44487098 INST. INSTRUCTIONS - 44487106 INST. INSTRUCTIONS - 44487080 INST. INSTRUCTIONS - 44487106 INST. INSTRUCTIONS - 44487106 Fire Alarm Input Board (Optional) 900-FA (Requires one option board above) INST. INSTRUCTIONS - 44487072 Battery Backup Board (Optional) 900-BB INST. INSTRUCTIONS - 44487064 AC Monitor Output Form C Contacts, 30 VDC, 1 Amp, Resistive Load 900-2RS Specifications: Inputs I1,I2 Dry contacts required (Closed = Active) Connect control contacts between SC (Signal Common) and any input Outputs O1,O2 • 12/24VDC, 3A (wet) when AC powered • 9.6-13.2VDC or 19.2-26.4VDC when battery powered • May be used with PS914 to power EL device at 24VDC, 16A, 300ms • Maximum load cannot exceed power supply ratings or 3A for outputs combined Board Input Power Board requires 0.1A max. of power supply output current to operate Temperature Range 32°-120° F (0°- 49° C) Compliance UL 294, ULC-S318, RoHS, & FCC Part 15 Fire Alarm Input Accepts 900-FA Fire Alarm Board (Optional) © 2010 Ingersoll-Rand Company 1-877-671-7011 44487056 Rev. 10/10_a 1 of 4 MOUNTING NOTES The PS914 must be installed in accordance with the article 760 of the National Electrical Code or NFPA 72, Canadian Electrical Code, or any other applicable codes. Install the PS914 indoors within the protected premises. Check national and local codes for additional installation requirements. Enclosure must be firmly mounted to a solid surface using hardware suitable for the surface. 1 MOUNT POWER SUPPLY 1a 1b Mark 2 Top Holes Secure Enclosure with 4 Screws x x Board not shown for clarity 2 SECURE ENCLOSURE DOOR If No Keylock If Keylock Enclosure will be secured with 2 screws as shown (done as last step) Remove knockout and insert key cylinder, then slide in clip OR a 2 of 4 b 3 PS914 SETUP AND TESTING 3a Connect AC Wiring AC Input ! Green (Ground) White (Neutral) Black (Hot) NEU LINE AC (In) 120/240 VAC DANGER: Ensure AC Breaker is Turned Off 900-BB Connector ! DANGER High Voltage 3b 24 VDC Output Setting 24 If main board must be removed, turn off AC power and wait 8 minutes before removal Use Jumper to Select 24 VDC or 12 VDC Output 12 Do not remove this cover, no serviceable parts 12 VDC Output Setting F1 OR NC C NO Note: Minimum of 1/4” separation between AC and DC wiring as well as power limited and non-power limited. AC Monitor Active when AC present and F1 fuse not open (Form C dry contacts) AC Input (Green LED) ! DANGER: Refer to 900-BB instructions for additional info Battery Supervision Terminals (Form C Dry Contacts) Place Batteries in Box with Terminals to the Left 4b 12/24 VDC Output Terminals If AC LED is off, turn off AC breaker prior to checking F1 fuse 4 INSTALL 900-BB BATTERY BACKUP (IF INCLUDED) 4a DC Output (Red LED) NO C NC (Shown AC Off) Attach Wires from Battery Board Active Inactive Red wires = (+) Black wires = (-) AC On AC Off BB LED (Amber) + Red Wires = (+) ry tte Ba On-Solid On-Blinking AC On AC Off Batteries Charging Batteries Supplying Power + Note: Allow 24 hours for batteries to fully charge 2 ery 1 tt Ba Black Wires = (-) 5 TURN ON AC BREAKER TO TEST POWER SUPPLY • • • Verify AC LED is On = GREEN Verify DC LED is On = RED Verify BB LED (if applicable) is On = AMBER 3 of 4 6 INSTALL 900-2RS OPTION BOARD (IF REQUIRED) ! Ensure AC breaker is turned off when installing or wiring option boards Use Jumper to Select Function 6b Plug 2RS Cable into any Available Option Connector Option 1 2 Option 2 6a DANGER: 1 6c OR Sequential Secure Board with Screws Note: 24VDC output setting required when EL device connected If installing board in location 2, rotate board 180˚ Individual 7 CONNECT WIRING TO 900-2RS OPTION BOARD Individual Mode - Typical Wiring Sequential Mode - Typical Wiring 120/240 VAC Input I1 will activate output 1 Input I2 will activate output 2 50/60Hz 120/240 VAC 50/60Hz 2RS Input I1 will activate both outputs 2RS SC I1 01 I2 02 GND A A SC I1 01 I2 02 GND EPT-2/10 B Access Control for Device 2 EL Device 2 (not polarized) A EPT-2/10 EPT-2/10 B A Access Control for Devices 1 & 2 EPT-2/10 B Note: Fail secure output only allowed if approved by Authority Having Jurisdiction Access Control for Device 1 EL Device 2 (not polarized) EL Device 1 (not polarized) 8 IF PS-914 HAS OTHER OPTION BOARDS, SEE THEIR INSTRUCTIONS Wire table (suggested maximum) Wire Ga (AWG) Device Current (Amps DC) Output* (max. ft) 14 0.3 850 0.5 500 0.3 340 0.5 200 18 12 NOTE: WHEN INSTALLATION IS COMPLETE, SECURE ENCLOSURE DOOR WITH SCREWS OR KEYLOCK 4 of 4 EL Device 1 (not polarized) 14 12 14 Using EL device with EPT or Door Loop (PS914 required) Using EL device with Electric Hinge/Pivot (PS914 required) Input (max. ft) 200 100 150 75 *Wiring allows for 10% voltage drop at device current at 12 or 24VDC Max. ft = one way distance between power supply and device 1200 Installation Instructions 900-4RL Option Board 44487080 ! DANGER: To avoid risk of electric shock, turn off AC power to power supply before installing or wiring option board 900-4RL Specifications: Inputs I1-I4 Dry contacts required (Closed = Active) Connect control contacts between SC (Signal Common) and any input Outputs O1-O4 • Form C contacts rated 30VDC, 3A (Dry) • 12/24VDC, 3A (Wet) when AC powered • 9.6-13.2VDC or 19.2-26.4VDC when battery powered • May be used with PS914 to power EL device at 24VDC, 16A, 300ms • Maximum load cannot exceed power supply ratings or 6A for outputs combined Board Input Power Board requires 0.18A max. of power supply output current to operate Temperature Range 32°-120°F (0°- 49° C) Compliance UL 294, ULC-S318, RoHS, & FCC Part 15 Fire Alarm Input Accepts 900-FA Fire Alarm Board (Optional) 1 INSTALL 4RL BOARD(S) INTO POWER SUPPLY 1a Review Available 900-4RL Mounting Locations (Gray) Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. 1b PS902 Plug 4RL Cable into any Available Option Connector Option 1 1 Option 1 Option 2 Option 1 Option 2 1 PS902 PS904, 914 PS914 1 2 1c PS906 1 2 3 © 2010 Ingersoll-Rand Company 1-877-671-7011 44487080 Rev. 10/10_a Option 3 PS904 PS906 Secure Board(s) with Screws Note: For UL listed installations, use only UL listed locks and strikes 2 CHOOSE FUNCTION OF 900-4RL BOARD BY SETTING SW2 DIP SWITCHES ON 4TD Four Zone Controller Function (4TD): Controls up to four inputs and four outputs with time delay. This is the default setting. Function LED will blink one time every 5 seconds AO Auto Operator Function (AO): Coordinates the unlocking of one or two zones with the signaling of an auto operator. Function LED will blink two times every 5 seconds SI Security Interlock Function (SI): Controls multi-door interlocks. Two through six door systems are possible (additional boards required for three to six doors). Function LED will blink three times every 5 seconds OFF 1 2 ON OFF 1 2 SW2 OFF ON SW1 ON 1 2 OFF 1 2 Function LED (D17) 3 TO COMPLETE CONFIGURATION AND WIRING, GO TO APPROPRIATE SECTION For 4TD: Go to pages 3-4 For AO: Go to pages 5-6 For SI: Go to pages 7-8 Basic Troubleshooting: Go to page 8 (OPTIONAL) DRY CONTACT CONFIGURATION Powered Outputs (Default) Dry Contact Outputs (Optional) B y default, all outputs pr ovide12/24VDC Fo r d r y co n ta ct o u tp u ts, r e m ove a p p r o p r i a te j um pers and r o ta te 90 ˚ , th e n r e i n sta l l ( Zo n e 1 - Zo n e 4 ) Jumper s factor y installed 2 Ju m p e r r o ta te d 90 ˚ Z one 2 Out put 2 Zo n e 2 O u tp u t 2 Z one 4 Out put 4 Zo n e 4 O u tp u t 4 Z one 3 Out put 3 Zo n e 3 O u tp u t 3 Z one 1 Out put 1 Zo n e 1 O u tp u t 1 4TD - SET TIME DELAY USING SW1 DIP SWITCHES Summary of Operation • Output turns “ON” when input is activated (closed). • Time delay begins when input is released (opened). • Locking Device output will remain “ON” during time delay. • If I1-I4 inputs are wired together, outputs will sequence. DIP switches on SW1 can be turned “ON” by moving them in the direction that the arrow is pointing. Switches below shown in “OFF” position SW1 ON OFF 1 2 3 4 5 6 7 8 SWITCH NUMBER Enable Time Delay Allows you to choose which outputs will have the below time delay. Set Time Delay (0-75 seconds, 5 second increments) 0 Sec: Switches 5-8 “OFF” 75 Sec: Switches 5-8 “ON” SW1 SW2 12345678 12 4TD DIP SWITCH DEFINITIONS All switches shown in “OFF” position in wiring diagram 1 Turn “ON” to enable time delay for Locking Device 1 2 Turn “ON” to enable time delay for Locking Device 2 3 Turn “ON” to enable time delay for Locking Device 3 4 Turn “ON” to enable time delay for Locking Device 4 5 Adds 5 seconds to the time delay when “ON” 6 Adds 10 seconds to the time delay when “ON” 7 Adds 20 seconds to the time delay when “ON” 8 Adds 40 seconds to the time delay when “ON” 4TD INPUT / OUTPUT TERMINAL BLOCK DEFINITIONS Input 1 Access Control 1 Input 2 Access Control 2 Input 3 Access Control 3 Input 4 Access Control 4 Output 1* Lock 1 Output 2* Lock 2 Output 3* Lock 3 Output 4* Lock 4 *See page 2 for dry contacts 3 4TD - WIRING EXAMPLE - FAIL SECURE PS914 x 4RL 120/240 VAC 50/60Hz EPT 2 or 10 EPT 2 or 10 4RL GND GND NC4 NC2 EL Device 2 (not polarized) C4 C2 Access Control 2 NO4 NO2 NC3 NC1 C3 C1 NO3 NO1 I3 I1 0-100 ft, use 14 gauge stranded wire 0-200 ft, use 12 gauge stranded wire Access Control 1 EPT 2 or 10 SC SC EL Device 1 (not polarized) EL Device 4 (not polarized) I4 I2 EPT 2 or 10 Access Control 4 Access Control 3 EL Device 3 (not polarized) Note: To control EL1 & EL2 with Access Control 1, jumper I1-I2 To control EL1 - EL4 with Access Control 1, jumper I1-I2-I3-I4 Note: Fail secure output only allowed if approved by Authority Having Jurisdiction 4TD - WIRING EXAMPLE - FAIL SAFE PS902 or PS904 or PS906 Mag Lock 2 120/240 VAC 50/60Hz Mag Lock 4 4RL GND NC2 Access Control 2 C2 NO2 I2 NC1 C1 NO1 Mag Lock 1 I1 SC Access Control 1 4 GND NC4 C4 NO4 Access Control 4 I4 NC3 C3 NO3 I3 SC Access Control 3 Note: To control Mag Locks 1 & 2 with Access Control 1, jumper I1-I2 To control Mag Locks 1 - 4 with Access Control 1, jumper I1-I2-I3-I4 Refer to Wire Table (page 7) Mag Lock 3 AO - SET CONFIGURATION USING SW1 SWITCHES DIP switches on SW1 can be turned “ON” by moving them in the direction that the arrow is pointing. Switches below shown in “OFF” position SW1 ON OFF 1 2 3 4 5 6 7 SW1 SW2 12345678 12 8 SW1 SWITCH AO DIP SWITCH DEFINITIONS All switches shown in “OFF” position in wiring diagram NUMBER Set Auto Operator Signaling Option Determines when the auto operator signal will be active 1 Off 2 Off Operator is signaled when latch monitor switch becomes active. Monitor switch required 1 On 2 Off Operator is signaled 0.5 seconds after control switch becomes active. No monitor switch used. 1 Off 2 On Operator is signaled 1.0 seconds after control switch becomes active. No monitor switch used. 1 On 2 On Operator is signaled 1.5 seconds after control switch becomes active. No monitor switch used. Not Used 3 Not used Set Individual Mode or Sequential Mode Individual Mode - One input will trigger one locking device. Sequential Mode - One input will trigger two locking devices. 4 Turn “OFF” (default) to enable Individual Mode (single doors). Turn “ON” to enable Sequential Mode (double doors). Set Time Delay* (0-30 seconds, 2 second increments) 0 Sec: Switches 5-8 “OFF” 30 Sec: Switches 5-8 “ON” 5 Adds 2 seconds to the time delay when “ON” 6 Adds 4 seconds to the time delay when “ON” 7 Adds 8 seconds to the time delay when “ON” 8 Adds 16 seconds to the time delay when “ON” * Time Delay begins when an input is released. AO INPUT / OUTPUT TERMINAL BLOCK DEFINITIONS Input 1 Access Control 1 Input 2 Lock Monitor 1 Input 3 Access Control 2 Input 4 Lock Monitor 2 Output 1* Lock 1 Output 2* AO Signal 1 Output 3* Lock 2 Output 4* AO Signal 2 *See page 2 for dry contacts 5 AO - WIRING EXAMPLE - TWO SINGLE DOORS Summary of Operation SW1 For each door, access control input unlocks door. Latch monitor (LX) triggers auto operator. PS914 x 4RL Single Door Board Configuration 1. Position jumpers for dry contact for outputs 2 and 4 (see page 2). 2. Turn on switches 5 and 6 on SW1 (6 second time delay). 3. If LX is not used, turn on switch 1 on SW1. 120/240 VAC 50/60Hz 1 GND 6 7 8 1 2 Auto Operator 2 EPT 10 Gray White NC3 LX C3 C1 (Optional) EL EL NO3 NO1 EL-LX Device 2 I3 I1 Access Control for Device 1 5 I4 NC1 EL-LX Device 1 4 NO4 White (Optional) 3 C4 I2 LX 2 NC4 NO2 EPT 10 OFF GND C2 Gray ON 4RL NC2 Auto Operator 1 SW2 Access Control for Device 2 SC SC 0-100 ft, use 14 gauge stranded wire 0-200 ft, use 12 gauge stranded wire AO - WIRING EXAMPLE - DOUBLE DOORS SW1 Summary of Operation Access control input unlocks both doors. Both latch monitors (LX) trigger auto operators. ON PS914 x 4RL 120/240 VAC 50/60Hz Double Door Board Configuration 1. Position jumpers for dry contact for outputs 2 and 4 (see page 2). 2. Turn on switches 4, 5, and 6 on SW1 (6 second time delay). GND 3. If LX is not used, turn on switch 1 NC2 on SW1. C2 NO2 I2 Note: Fail secure output only allowed if approved by Authority Having Jurisdiction NC1 C1 NO1 I1 SC Refer to Wire Table (page 7) OFF 1 2 3 4 5 6 7 8 1 2 4RL GND 0-100 ft, use 14 gauge stranded wire 0-200 ft, use 12 gauge stranded wire NC4 C4 NO4 I4 NC3 C3 Second auto operator, if needed NO3 I3 Auto Operator Auto Operator SC EPT 10 Gray White White Gray LX EL (Optional) EL-LX Device 1 Access Control for Devices 1&2 6 SW2 EPT 10 LX (Optional) EL EL-LX Device 2 SI - CONFIGURE SW1 DIP SWITCHES DIP switches on SW1 can be turned “ON” by moving them in the direction that the arrow is pointing. Switches below shown in “OFF” position SW1 ON OF F 1 2 3 4 5 6 7 8 SWITCH NUMBER Enable Time Delay Allows you to choose which outputs will have the below time delay. Enable Interlock Set Time Delay (Output Active)* (0-30 seconds, 2 second increments) 0 Sec: Switches 5-8 “OFF” 30 Sec: Switches 5-8 “ON” SW1 SW2 12345678 12 SI DIP SWITCH DEFINITIONS All switches shown in “OFF” position in wiring diagram 1 Turn “ON” to enable time delay for Locking Device 1 2 Turn “ON” to enable time delay for Locking Device 2 3 Turn “ON” to remove O2 from interlock (Allows a single independent door) 4 Turn “ON” for global interlock (interlocks with other SI boards that have this switch “ON”) 5 Adds 2 seconds to the time delay when “ON” 6 Adds 4 seconds to the time delay when “ON” 7 Adds 8 seconds to the time delay when “ON” 8 Adds 16 seconds to the time delay when “ON” SI INPUT / OUTPUT TERMINAL BLOCK DEFINITIONS Input 1 Access Control 1 Input 2 Access Control 2 Input 3 Lock Monitor 1 Input 4 Lock Monitor 2 Output 1* Lock 1 Output 2* Lock 2 Output 3* Follows Output 1 by .5 Sec Output 4* Follows Output 2 by .5 Sec GLOBAL INTERLOCK SWITCH SETTING EXAMPLES SI Board #1 SI Board #2 SI Board #3 Application SW1-3 SW1-4 SW1-3 SW1-4 SW1-3 SW1-4 Off Off Off Off Off Off Each SI board is a standalone, 2-door interlock. Off On Off On Off On 6-door interlock by setting all boards “global”. Off On On On Off On Off On A three-door interlock, plus an additional independent door on output 2 of SI Board #2. Off *See page 2 for dry contacts Off 4-Door interlock (SI Board #1,2) and a standalone 2-door interlock (SI Board #3). Wire table (suggested maximum) Wire Ga (AWG) Device Current (Amps DC) Output* (max. ft) 14 0.3 850 0.5 500 0.3 340 0.5 200 Using EL device with EPT or Door Loop (PS914 required) 200 Using EL device with Electric Hinge/Pivot (PS914 required) 150 18 12 14 12 14 Input (max. ft) *Wiring allows for 10% voltage drop at device current at 12 or 24VDC Max. ft = one way distance between power supply and device 1200 100 75 7 SI - WIRING EXAMPLE - 2 TO 6 DOOR INTERLOCK, NORMALLY LOCKED SI Configuration SW1 1.Turn on switches 1, 2, 4, 5, and 6 on SW1. 2. Install 2 doors per SI board. 3. Add up to 2 additional SI boards for a total of 6 door interlock per power supply: PS902 (2 doors maximum) PS904 (4 doors maximum) PS906 (6 doors maximum) ON PS904 x 4RL C2 NO2 I2 NC1 C1 Access Control 2 OFF 1 NC2 Mag Lock 2 120/240 VAC 50/60Hz 2 3 4 5 6 7 8 1 2 4RL GND DPS 2 (contact shown with door closed) SW2 NO1 I1 SC GND NC4 C4 NO4 DPS 1 (contact shown with door closed) I4 Mag Lock 1 NC3 C3 NO3 I3 Access Control 1 SC Note: Fail secure output only allowed if approved by Authority Having Jurisdiction Refer to Wire Table (page 7) BASIC TROUBLESHOOTING FOR ALL FUNCTIONS Symptom Check 900-4RL Function LED (yellow) is not blinking, and inputs and outputs are inactive Verify 900-4RL cable is plugged into an “option” connector on the main board. Check AC wiring and AC breaker. Check PS-900 main board F1 fuse. Use voltmeter to verify 12 VDC or 24 VDC output on PS-900 main board. 900-4RL Function LED (yellow) is blinking, but inputs and outputs are inactive If 900-FA option is installed onto 900-4RL, verify fire alarm contacts are closed across FA1 and FA2. Inputs and outputs behaving incorrectly. Verify 2-position DIP switch is set for proper function. Watch yellow LED to confirm 4RL function setting . See page 2. (Verify each DIP switch is pushed into its fully-on or fully-off position.) If 900-FA option is not installed, then verify jumper wire is installed into FA-JMPR connector on the 4RL board. Verify 8-position DIP switch is set properly for your application. If you are unsure of proper settings, contact Technical Services for assistance. (Verify each DIP switch is pushed into its fully-on or fully-off position.) Verify wiring for all input and output hardware is connected to proper terminals. (Reminder: If 900-4RL is mounted in location 1, top terminals will be GND. If 900-4RL mounted in location 2 or 3, top terminals will be SC.) NOTE: WHEN INSTALLATION IS COMPLETE, SECURE ENCLOSURE DOOR WITH SCREWS OR KEYLOCK 8 Installation Instructions 900-FA Fire Alarm Input 44487072 Input (Fire Alarm) Dry contacts required (Closed = no fire alarm) Connect control contacts between FA1 and FA2 Output (Supervision) 30VDC, 1A resistive dry contact Board Input Power Board requires 0.05A max. of power supply output current to operate Temperature Range 32°-120° F (0°- 49° C) Compliance UL 294, ULC-S318, RoHS, & FCC Part 15 ! The 900-FA Fire Alarm board can be installed on any one of the following power supply or option boards (refer to installation instructions): DANGER: To avoid risk of electric shock, turn off AC power to power supply before installing or wiring 900-FA board. In the event a fire alarm is active, this board will remove power from the PS902 DC output and any 900-series option board output. : ! NING WAR : NING ! WAR R ! DANGE F1 : GER ! DAN PS902 Power Supply • • • 1a 900-2RS (2 Relay) 900-2Q (2 Relay w/com) If 900-FA was factory installed, go to step 2 If installing to option board, go to 1a If installing to PS902 main board, go to 1b 900-4R (4 Relay) 900-4RL (4 Relay w/logic) 900-8F (8 Zone Distribution-fuse) 900-8P (8 Zone Distribution-PTC) IF INSTALLING TO OPTION BOARD Choose Option Board where 900-FA is to be Installed Remove Jumper from Option Board (900-2RS option board shown) 2 Install 900-FA to Option Board 1 3 Note: If using battery backup, location 3 is not available. Option board may be in any of these three locations. © 2010 Ingersoll-Rand Company 1-877-671-7011 44487072 Rev. 10/10_a 1b IF INSTALLING TO PS902 MAIN BOARD Remove Jumper Install 900-FA Here Note: Complete power failure shall result in a fail safe operation. When connected to a fire alarm releasing control unit, total loss of power for the locking mechanisms shall be configured for a fail safe operation. 2 900-FA WIRING Terminal Definitions NC C NO FA1 Supervision Output Contacts Shown FA Active (open) One 900-FA Board - Automatic Reset NC C NO FA1 FA2 FA2 Note: Use 18 gauge wire for all wiring. Wire length dependent on physical layout. Fire Alarm Input One 900-FA Board - Manual Reset NC C NO FA1 FA2 Manual Reset (Temporarily close to reset) Fire Alarm Contact Closed = no fire Open = fire Fire Alarm Contact Closed = no fire Open = fire Two 900-FA Boards on one power supply Automatic Reset Two 900-FA Boards on two power supplies Automatic Reset NC C NO FA1 FA2 NC C NO FA1 FA2 NC C NO FA1 FA2 NC C NO FA1 FA2 Fire Alarm Contact Closed = no fire Open = fire Fire Alarm Contact Closed = no fire Open = fire NOTE: WHEN INSTALLATION IS COMPLETE, SECURE ENCLOSURE DOOR WITH SCREWS OR KEYLOCK Installation Instructions 900-BB Battery Backup 44487064 ! DANGER: To avoid risk of electric shock, turn off AC power to power supply before installing or wiring 900-BB board BATTERY SPECIFICATIONS Battery Life Model PS906 = 6A @ 24V Model PS904 = 4A @ 24V Model PS902 = 2A @ 24V Model PS914 = 4A @ 24V } Suitable for Canadian Class IV standby power for access control Battery Type 12VDC, 7Ah Gel Sealed Rechargeable Battery (2 included) 5 Year Service Life Replacement Part Number Schlage 991280 ! CAUTION: Charge only Schlage 991280 batteries. Other types may burst, causing personal injury and damage. Observe the proper polarity when connecting the batteries. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. 1 INSTALL 900-BB ONTO MAIN CIRCUIT BOARD AND SECURE WITH SCREW Plug Connector Here (PS914 main board shown) Secure with Screw Here © 2010 Ingersoll-Rand Company 1-877-671-7011 44487064 Rev. 10/10_a 2 INSTALL AND CONNECT BATTERIES 2a 2b 2c NO C NC Place Batteries in Box with Terminals to the Left (Shown AC Off) Active Inactive AC On AC Off Attach Wires from Battery Board Red wires = (+) Black wires = (-) BB LED (Amber) + Red Wires = (+) ry tte Ba Verify That Battery LED is On If LED is not on, cycle AC power off and then back on. Note: Allow 24 hours for batteries to fully charge ! 2 On-Solid On-Blinking AC On AC Off Batteries Charging Batteries Supplying Power + 2d Battery Supervision Terminals (Form C Dry Contacts) Turn On AC Breaker to Energize Power Supply ry tte Ba 1 Black Wires = (-) WARNING: Incorrect connection may cause damage to the batteries NOTE: WHEN INSTALLATION IS COMPLETE, SECURE ENCLOSURE DOOR WITH SCREWS OR KEYLOCK Installation Instructions 900-FA Fire Alarm Input 44487072 Input (Fire Alarm) Dry contacts required (Closed = no fire alarm) Connect control contacts between FA1 and FA2 Output (Supervision) 30VDC, 1A resistive dry contact Board Input Power Board requires 0.05A max. of power supply output current to operate Temperature Range 32°-120° F (0°- 49° C) Compliance UL 294, ULC-S318, RoHS, & FCC Part 15 ! The 900-FA Fire Alarm board can be installed on any one of the following power supply or option boards (refer to installation instructions): DANGER: To avoid risk of electric shock, turn off AC power to power supply before installing or wiring 900-FA board. In the event a fire alarm is active, this board will remove power from the PS902 DC output and any 900-series option board output. : ! NING WAR : NING ! WAR R ! DANGE F1 : GER ! DAN PS902 Power Supply • • • 1a 900-2RS (2 Relay) 900-2Q (2 Relay w/com) If 900-FA was factory installed, go to step 2 If installing to option board, go to 1a If installing to PS902 main board, go to 1b 900-4R (4 Relay) 900-4RL (4 Relay w/logic) 900-8F (8 Zone Distribution-fuse) 900-8P (8 Zone Distribution-PTC) IF INSTALLING TO OPTION BOARD Choose Option Board where 900-FA is to be Installed Remove Jumper from Option Board (900-2RS option board shown) 2 Install 900-FA to Option Board 1 3 Note: If using battery backup, location 3 is not available. Option board may be in any of these three locations. © 2010 Ingersoll-Rand Company 1-877-671-7011 44487072 Rev. 10/10_a 1b IF INSTALLING TO PS902 MAIN BOARD Remove Jumper Install 900-FA Here Note: Complete power failure shall result in a fail safe operation. When connected to a fire alarm releasing control unit, total loss of power for the locking mechanisms shall be configured for a fail safe operation. 2 900-FA WIRING Terminal Definitions NC C NO FA1 Supervision Output Contacts Shown FA Active (open) One 900-FA Board - Automatic Reset NC C NO FA1 FA2 FA2 Note: Use 18 gauge wire for all wiring. Wire length dependent on physical layout. Fire Alarm Input One 900-FA Board - Manual Reset NC C NO FA1 FA2 Manual Reset (Temporarily close to reset) Fire Alarm Contact Closed = no fire Open = fire Fire Alarm Contact Closed = no fire Open = fire Two 900-FA Boards on one power supply Automatic Reset Two 900-FA Boards on two power supplies Automatic Reset NC C NO FA1 FA2 NC C NO FA1 FA2 NC C NO FA1 FA2 NC C NO FA1 FA2 Fire Alarm Contact Closed = no fire Open = fire Fire Alarm Contact Closed = no fire Open = fire NOTE: WHEN INSTALLATION IS COMPLETE, SECURE ENCLOSURE DOOR WITH SCREWS OR KEYLOCK Installation Instructions 900-BB Battery Backup 44487064 ! DANGER: To avoid risk of electric shock, turn off AC power to power supply before installing or wiring 900-BB board BATTERY SPECIFICATIONS Battery Life Model PS906 = 6A @ 24V Model PS904 = 4A @ 24V Model PS902 = 2A @ 24V Model PS914 = 4A @ 24V } Suitable for Canadian Class IV standby power for access control Battery Type 12VDC, 7Ah Gel Sealed Rechargeable Battery (2 included) 5 Year Service Life Replacement Part Number Schlage 991280 ! CAUTION: Charge only Schlage 991280 batteries. Other types may burst, causing personal injury and damage. Observe the proper polarity when connecting the batteries. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. 1 INSTALL 900-BB ONTO MAIN CIRCUIT BOARD AND SECURE WITH SCREW Plug Connector Here (PS914 main board shown) Secure with Screw Here © 2010 Ingersoll-Rand Company 1-877-671-7011 44487064 Rev. 10/10_a 2 INSTALL AND CONNECT BATTERIES 2a 2b 2c NO C NC Place Batteries in Box with Terminals to the Left (Shown AC Off) Active Inactive AC On AC Off Attach Wires from Battery Board Red wires = (+) Black wires = (-) BB LED (Amber) + Red Wires = (+) ry tte Ba Verify That Battery LED is On If LED is not on, cycle AC power off and then back on. Note: Allow 24 hours for batteries to fully charge ! 2 On-Solid On-Blinking AC On AC Off Batteries Charging Batteries Supplying Power + 2d Battery Supervision Terminals (Form C Dry Contacts) Turn On AC Breaker to Energize Power Supply ry tte Ba 1 Black Wires = (-) WARNING: Incorrect connection may cause damage to the batteries NOTE: WHEN INSTALLATION IS COMPLETE, SECURE ENCLOSURE DOOR WITH SCREWS OR KEYLOCK ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- 4 Amps output
- 24VDC, 16A, 300ms power
- 14” H x 12” W x 4” D enclosure
- 8 knockouts
- UL, ULC, RoHS, FCC compliant
- Compatible with option boards
Frequently asked questions
The PS914 provides 4 Amps DC @ 12/24 VDC.
Yes, the PS914 can be used to power Von Duprin and Falcon EL devices at 24VDC, 16A, 300ms.
The maximum load cannot exceed the power supply ratings or 3A for outputs combined.
The PS914 enclosure is 14” H x 12” W x 4” D.
The PS914 is UL 294, ULC-S318, RoHS, & FCC Part 15 compliant.