Generator Stock
Products Catalog
• Portables
• Towables
• Light Towers
• Automatic Emergency Standby
• Commercial/Industrial Standby
CA2400
Effective Date:
May, 2005
Table of Contents
Why Baldor Generators? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Premier Portables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Powerchief Portables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Industrial Diesel Portables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Receptacle Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Towable Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
POW’R LITE Light Towers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
DLC (Diesel Liquid Cooled) Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
AE (Automatic Emergency) Standby Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
GLC (Gaseous Liquid Cooled) Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Transfer Switches & Other Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Generator Selection Guide and Electrical Formulas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inside Back Cover
Baldor District Offices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Back Cover
BALDOR GENERATORS OWNER WARRANTY POLICY
LIMITED WARRANTY
Baldor Generators will replace or repair free of charge any part or parts of the generator of their manufacture that are defective in workmanship and materials for a period of time
as set forth in the Warranty Period chart below.
All Baldor products requiring warranty service shall be transported or shipped freight pre-paid, at the risk of the party requiring warranty service, to a Baldor Generator repair facility.
Written notification of the alleged defect in addition to a description of the manner in which the Baldor generator is used, and the name, address and telephone number of the
party requiring warranty service must be included. Baldor is not responsible for removal and shipment of the Baldor product to the service center or for the reinstallation of
the Baldor product upon its return to the party requiring warranty service. Problems with Baldor products can be due to improper maintenance, faulty installation, non-Baldor
additions or modifications, or other problems not due to defects in Baldor workmanship or materials. If a Baldor Generator repair facility determines that the problem with a
Baldor product is not due to defects in Baldor workmanship or materials, then the party requesting warranty service will be responsible for the cost of any necessary repairs.
Genset engines are covered under the engine manufacturer's warranty. Proper engine maintenance is required. Any request for engine warranty or repair should be made
directly with the engine manufacturers warranty center. See engine manufacturers data for applicable engine warranty periods and location of repair centers. EXCEPT FOR
THE EXPRESSED WARRANTY SET FORTH ABOVE, BALDOR GENERATORS DISCLAIMS ALL OTHER EXPRESSED AND IMPLIED WARRANTIES INCLUDING THE IMPLIED
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. NO OTHER WARRANTY, EXPRESSED OR IMPLIED, WHETHER OR NOT SIMILAR
IN NATURE TO ANY OTHER WARRANTY PROVIDED HEREIN, SHALL EXIST WITH RESPECT TO THE GOODS SOLD UNDER THE PROVISIONS OF THESE TERMS AND
CONDITIONS. ALL OTHER SUCH WARRANTIES ARE HEREBY EXPRESSLY WAIVED BY THE BUYER. UNDER NO CIRCUMSTANCES SHALL BALDOR GENERATORS BE
LIABLE OR RESPONSIBLE IN ANY MANNER WHATSOEVER FOR ANY INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, OR ANTICIPATED PROFITS RESULTING
FROM THE DEFECT, REMOVAL, REINSTALLATION, SHIPMENT OR OTHERWISE. This is the sole warranty of Baldor Generators and no other affirmations or promises made
by Baldor Generators shall be deemed to create an expressed or implied warranty. Baldor Generators has not authorized anyone to make any representations or warranties
other than the warranty contained herein.
WARRANTY PERIOD
Generator Series
Labor*
Parts
Portable Products
(Premier, Powerchief, DG Series, K Series)
1 Year
3 Years
Towable Products (TS)
1 Year or 3,000 Hours
Whichever Comes First
3 Years or 3,000 Hours – Whichever comes first
POW’R LITE Light Towers
1 Year or 3,000 Hours
Whichever Comes First
3 Years or 3,000 Hours – Whichever comes first
Excluded from any warranty coverage regardless of time period:
Light Fixture, Lamps and Ballasts
3600 RPM Standby Systems
(Some AE Models)
1 Year or 1,000 Hours
Whichever Comes First
3 Years or 1,000 Hours – Whichever comes first
1800 RPM Standby Systems
(Some AE Models, DLC, GLC)
1 Year or 3,000 Hours
Whichever Comes First
3 Years or 3,000 Hours – Whichever comes first
International
1 Year or 1,000 Hours
Whichever Comes First
1 Year or 1,000 Hours – Whichever comes first
*For products covered under labor coverage, travel expenses will be allowed up to 7 hours straight labor or 300 miles, whichever occurs first and only applies to permanently
wired and mounted products (AE, DLC, GLC models).
YOU MUST SAVE THE PURCHASE RECEIPT. PROOF OF PURCHASE DATE SERIAL NUMBER AND MODEL NUMBER WILL BE REQUIRED FOR ALL
PORTABLE AND TOWABLE PRODUCTS TO QUALIFY FOR ANY WARRANTY CONSIDERATION.
A START-UP INSPECTION FORM / WARRANTY REGISTRATION MUST BE COMPLETED IN ITS ENTIRETY AND SUBMITTED TO BALDOR GENERATORS
WITHIN 30 DAYS OF START-UP TO QUALIFY FOR ANY WARRANTY CONSIDERATION, EXCLUDING: PORTABLES, TOWABLES AND LIGHT TOWERS.
Baldor Generators
The Broadest Line In The Industry – 1.1kW to 2MW
• Industrial Portables – 1,100 Watts to 11,000 Watts
– An industrial tool that delivers performance and value to any industrial job
– The generator of choice in the rental and construction industry
• TS Towable Generators – 25kVA to 250kVA
– Sound attenuated enclosure for “quiet” operation in noise restricted areas
– Selective single and three phase voltages
– Full featured units specially suited for all industrial, commercial and rental
applications
• Automatic Emergency (AE) Residential and Commercial Standby Power –
8kW to 25kW
– Engineered to be trouble free, AE units have solid state controls, world class
engines and brushless alternators
– Advanced noise reduction technology—weatherproof enclosure made of heavy
gauge material and sound insulated
• GLC-Gaseous Liquid Cooled Industrial Standby Power – 30kW to 125kW
– Reliable GM engine
– Custom built around your requirements
– Quick delivery
• DLC-Diesel Liquid Cooled Industrial Agricultural Standby Power –
30kW to 200kW
– Reliable John Deere engine
– Engineered with top of the line components, these units are easy to use and
reliable, providing the protection deserved in the event of a power failure
– Direct fuel line connections for use with existing tanks or provisions for optional
sub-base tank. Optional flexible fuel lines available.
• Baldor Pow’R Lite Light Towers – 6kW Liquid Cooled 1800 RPM
– (4) 1000 watt halide lamps
– 30 ft. extended tower
– 4 section mast (for compact trailering)
1
Premier Industrial Portable Generators
(Full Featured)
Applications
Baldor portable generators are designed to meet your demands when
dependable portable power is required. The performance and durability of
Baldor portables have made them the “generator of choice” for industrial
and rental/construction applications. Baldor’s brushless two-pole design is
maintenance free and manufactured to the highest quality standards in an ISO
9001 facility.
OHV30
Features
Baldor portable generators are equipped with industrial grade engines
to provide the performance and dependability you can count on. Baldor
manufactures it’s own generators and backs them with an industry leading 3year limited warranty. Baldor portable generators also feature “Switchless Full
Pow’R”, eliminating the need for a “Full Power” switch. Automatically get the
120V or 240V nameplate power rating without having to flip a switch.
Baldor Premier portable generators incorporate the features you’ve come to
expect from the leader in portable power generation.
• "Switchless Full Power" – Automatic 120V/240V operation.
• “Automatic Idler System” – Reduces fuel consumption, extends engine life.
• “Focal Vibration System” – Reduces vibration, extends generator life.
• Hour meter, Voltmeter, and Fuel Gauge
OHV85E
Premier
(Full Featured)
Catalog
Number
Max.
Watts
Cont.
Watts
Fuel
Capacity
Engine
Engine
Hp
Volts
List
Price
Mult.
Sym.
Approx.
Shpg.
Wgt. (lbs)
OHV30
3000
2500
2.8 Gal.
Honda
5.5
120 VAC
$1535
PG
121
R30
3000
2500
2.7 Gal.
Robin/Subaru
7.0
120 VAC
1508
PG
125
OHV40
4000
3500
4.6 Gal.
Honda
8.0
120/240 VAC
2181
PG
170
R45
4500
4000
5.0 Gal.
Robin
9.0
120/240 VAC
2074
PG
180
R45E 1
4500
4000
5.0 Gal.
Robin
9.0
120/240 VAC
2729
PG
187
OHV50H
5000
4000
4.6 Gal.
Honda
9.0
120/240 VAC
2380
PG
189
OHV60
6000
5000
4.6 Gal.
Honda
11.0
120/240 VAC
2807
PG
214
OHV60E 1
6000
5000
4.6 Gal.
Honda
11.0
120/240 VAC
3270
PG
226
R60
6000
5000
5.0 Gal.
Robin/Subaru
13.5
120/240 VAC
2714
PG
213
R60E 1
6000
5000
5.0 Gal.
Robin/Subaru
13.5
120/240 VAC
3189
PG
223
OHV85E 1
9000
8000
5.8 Gal.
Vanguard
16.0
120/240 VAC
3697
PG
251
OHV100E 1
10500
9500
5.8 Gal.
Vanguard
18.0
120/240 VAC
6209
PG
316
OHV110E 1
11000
10000
5.8 Gal.
Honda
20.0
120/240 VAC
6914
PG
340
R45E, OHV60E, R60E, OHV85E, OHV100E and OHV110E have electric start and recoil start.
1 Batteries are not included on any Electric Start Models.
Baldor reserves the right to implement specification or design changes without notice.
WARNING: Do not connect generator to any building’s electrical system unless a disconnect switch has been installed.
Follow local and national electrical codes for proper installation.
NOTES:
2
Baldor Industrial Portable Generators
R45 or
Premier Model
Features
Switchless Full Pow’R
AC Voltmeter
Hourmeter
AC Circuit Breakers
Low Oil Shutdown
Automatic Idler
Spark Arrestor Muffler
Extended Run Fuel Tank
Tubular Roll Cage
Neoprene Isolators
Focal Vibration System
3-Year Warranty
OHV60 or
R60 or
OHV30
R30
OHV40
R45E 1
OHV50H
OHV60E 1
R60E 1
OHV85E 1
—
—
std
std
std
—
std
std
std
std
—
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
std
Honda
Honda
Vanguard
Vanguard
Honda
9.0
1
Splash
270
11
1
Splash
337
Recoil or
12 Volt
with Recoil
std
std
std
std
std
std
std
std
std
std
std
std
Robin/
Subaru
13.5
1
Splash
404
Recoil or
12 Volt
with Recoil
std
std
std
std
std
std
std
std
std
std
std
std
8.0
1
Splash
242
std
std
std
std
std
std
std
std
std
std
std
std
Robin/
Subaru
9.0
1
Splash
265
Recoil or
12 Volt
with Recoil
16
2
Pressure
480
18
2
Pressure
570
20
2
Pressure
614
12 Volt
with Recoil
12 Volt
with Recoil
12 Volt
with Recoil
OHV100E 1 OHV110E 1
Engine Model
Honda
Horsepower
Cylinder
Lubrication System
Displacement - CC
5.5
1
Splash
163
—
—
std
std
std
—
std
std
std
std
—
std
Robin/
Subaru
7.0
1
Splash
211
Starting Systems
Recoil
Recoil
Recoil
3000W
2500W
120VAC
20.8
69.9
3000W
2500W
120VAC
20.8
69
4000W
3500W
120/240VAC
29.2/14.6
73
4500W
4000W
120/240VAC
33.3/16.7
70
5000W
4000W
120/240VAC
33.3/16.7
73
6000W
5000W
120/240VAC
41.6/20.8
72.4
6000W
5000W
120/240VAC
41.6/20.8
71
9000W
8000W
120/240VAC
66.7/33.4
75.4
10500W
9500W
120/240VAC
79.2/39.6
75.3
11000W
10000W
120/240VAC
83.3/41.6
78
2-20AMP
2-20AMP
—
—
—
2-20AMP
2-20AMP
—
—
—
—
4-20AMP
1-30AMP
1-30AMP
—
—
4-20AMP
1-30AMP
1-30AMP
—
—
4-20AMP
1-30AMP
1-30AMP
—
—
4-20AMP
1-30AMP
1-30AMP
—
—
4-20AMP
1-30AMP
1-30AMP
—
—
4-20AMP
1-30AMP
1-30AMP
—
—
4-20AMP
1-30AMP
1-30AMP
1-50AMP
—
4-20AMP
1-30AMP
1-30AMP
1-50AMP
2.8
5 hrs.
8 hrs.
2.75
6 hrs.
9 hrs.
4.6
5 hrs.
9 hrs.
5.0
6 hrs.
10 hrs.
4.6
6 hrs.
10 hrs.
4.6
4 hrs.
7 hrs.
4.4
4 hrs.
7 hrs.
5.8
4 hrs.
7 hrs.
5.8
4 hrs.
6 hrs.
5.8
4 hrs.
6 hrs.
25.5”
17.5”
18.0”
112 lbs
26.5”
17.5”
20.5”
110 lbs
28"
20.5"
22.25"
170 lbs
28”
22”
23”
170/177 lbs
28”
20.5”
22.25”
170 lbs
28”
20.5”
22.25”
192/206 lbs
28”
22”
23”
195/200 lbs
28”
21.5”
27.5”
224 lbs
30”
23”
28.5”
270 lbs
30”
23”
28.5”
270 lbs
Rating
Max Rating
Rated
Volts
Amps
dBA @ 7 meters
Receptacles
Straight(520R)120V
Straight(520R GFCI)120V
Twist Lock(L530R)120V
Twist Lock(L1430R)120/240V
Twist Lock(CS6369)120/240V
Fuel System
Fuel Capacity (U.S. Gallons)
Operation Run Time/Full Load
Operation Run Time/Half Load
Dimensions
Length
Width
Height
Weight (Net Dry)
Honda
Recoil
NOTES: 1 Batteries are not included on any Electric Start Models.
Baldor reserves the right to implement specifications or design changes without notice.
WARNING: Do not connect generator to any building’s electrical system unless a disconnect switch has been installed.
Follow local and national electrical codes for proper installation.
Options - Portables
Catalog No.
Option
Available for Models
PGD2
2 Wheel Pneumatic Dolly Kit
Premier, Powerchief & Diesel Models only – 4500 - 9000 watts
List Price
PGD4
4 Wheel Pneumatic Dolly Kit
Premier, Powerchief & Diesel Models only – 4500 - 11,000 watts
272
CT5000A00SP
Home Power Connection Kit:
GenTran Manual Transfer Switch, 8 Circuit, 30 Amp
Extension Cord, Rain tight Power Inlet Box, PGD2
Premier, Powerchief and Diesel Models only
4500 watts thru 7,500 watts
974
CT5000A01SP
GenTran Manual Transfer Switch
12 Circuit, 50 Amp, Extension Cord, 50 Amp Power
Cord, Rain tight Power Inlet Box, PGD2
Premier, Powerchief and Diesel Models Only
4500 Watts thru 11,000 Watts
1080
Custom
50 Hz
PC30H, PC40H, PC50H, PC60H and PC90VE
469
Custom
3 Phase
PC30H, PC40H, PC50H ans PC60H
938
$208
3
Baldor Powerchief Series
When you need the dependability of a construction grade generator but could do without some of
the frills, Powerchief generators are for you. Available in 1100 to 9000 watt models, the competitively
priced Powerchief Series delivers performance and value found mostly on top-of-the-line generators.
Add to this the quality of an ISO 9001 certified manufacturing plant and a 3 year product warranty and
you’ll agree the Powerchief Series is tough to beat.
Powerchief Features
Switchless Full Pow’R
All the POWER, All the TIME!®
• Powerchief generators with “Switchless Full Pow’R” do not need a “power switch”.
We’re always full power!
• Plug in 120v or 240v in any combination.
• No need to change voltage settings.
• No need to worry about which cord is plugged in.
• No complicated formulas and instructions.
• Reduces the chance for generator damage.
Powerchief® Industrial
Portable Generators (Maximum Value)
Baldor Generators are known for their quality and performance and the Powerchief®
Series provides what you’ve come to expect in a maximum value generator. Powerchief
generators utilize the same engine and generator as the Premier Series but with limited
options. All Powerchief generators feature industrial grade engines, a Baldor generator
with 3-year limited warranty, Switchless Full Pow’R and Focal Vibration System.
PC60H
Catalog
Number
PC11R
PC30H 4
PC40H 4
PC50H 4
PC60H 4
PC60HE 4 1
PC90VE 4 1
Max.
Watts
1100
3000
4000
5000
6000
6000
9000
Cont.
Watts
900
2500
3500
4000
5000
5000
8000
Fuel
Capacity
1 Gal.
3.8 Qt.
4.6 Gal.
4.6 Gal.
4.6 Gal.
4.6 Gal.
4.6 Gal.
Engine
Robin/Subaru
Honda
Honda
Honda
Honda
Honda
Vanguard
Engine
Hp
2.0
5.5
8.0
9.0
11.0
11.0
16.0
Volts
120 VAC/12 VDC
120 VAC
120/240 VAC
120/240 VAC
120/240 VAC
120/240 VAC
120/240 VAC
List
Price
$1054
1345
1743
1965
2179
2729
2946
Mult.
Sym.
PG
PG
PG
PG
PG
PG
PG
Approx.
Shp. Wgt. (lbs)
55
108
162
200
207
213
232
NOTES: 1 Batteries are not included on any Electric Start Models.
4 50 Hz and/or 3 Phase output is available on selected models. Contact your local Baldor District Office for specifications and delivery.
See options on page 3.
Powerchief® Generators with Inverter Technology
PC17Ri
Catalog
Number
PC17RI
PC32RI
PC43RI
4
The Baldor Inverter Technology makes these generators ideallly suited for use with sensitive electronics
(e.g., computer, printer, and other sensitive electronic equipment) because the generator produces a
clean sine wave of energy that prevents surging. To prevent any possible damage to the unit, an Oil Alert
will shut the unit off when the oil drops below a safe operating level. Baldor Powerchief inverter units also
have a 12-volt DC terminal for use when charging automotive type batteries.
Max.
Watts
1650
3200
4300
Cont.
Watts
1400
2800
3800
Fuel
Capacity
4.2 Qt.
3.7 Gal.
4.2 Gal.
Engine
Robin/Subaru
Robin/Subaru
Robin/Subaru
Engine
Hp
2.4
7.0
9.0
Volts
120 VAC/12 VDC
120 VAC/12 VDC
120 VAC/12 VDC
List
Price
$1737
3048
3905
Mult.
Sym.
PG
PG
PG
Approx.
Shpg. Wgt. (lbs)
45
130
143
Baldor Industrial Portable Generators
PC11R
PC30H
PC40H
PC50H
Features
Switchless Full Pow’R
DC Circuit Breakers
AC Circuit Breakers
Low Oil Shutdown
Spark Arrestor Muffler
Extended Run Fuel Tank
Tubular Roll Cage
Neoprene Isolators
Focal Vibration System
3-Year Warranty
Engine Model
Horsepower
Cylinder
Displacement-CC
—
std
std
std
std
—
—
std
—
std
Robin
2.4
1
85.8
—
—
std
std
std
—
std
std
—
std
Honda
5.5
1
163
std
—
std
std
std
std
std
std
std
std
Honda
8
1
242
std
—
std
std
std
std
std
std
std
std
Honda
9
1
270
Starting Systems
Recoil
Recoil
Recoil
Recoil
1100W
900W
120VAC/
12VDC
9.1
59
3000W
2500W
4000W
3500W
120VAC
Powerchief Model
Rating
Max Rating
Rated
Volts
Amps
dBA @ 7 meters
Receptacles
Straight (515R) 120V
Straight (520R GFCI) 120V
Twist Lock (L530R) 120V
Twist Lock (L1430R) 120/240V
Fuel System
Fuel Capacity (U.S. Gallons)
Operational Run Time/Full Load
Operational Run Time/Half Load
Dimensions
Length
Width
Height
Weight (Net Dry)
PC60H or
PC90VE
PC17Ri 2
PC32Ri 2
PC43Ri 2
std
—
std
std
std
std
std
std
std
std
Honda
11
1
337
Recoil or 12V
std
—
std
std
std
std
std
std
std
std
Vanguard
16
2
480
12 Volt
—
std
std
std
std
—
—
std
—
std
Robin
2.4
1
85.8
—
std
std
std
std
std
—
std
—
std
Robin
7
1
211
—
std
std
std
std
std
—
std
—
std
Robin
9
1
265
with Recoil 1
with Recoil 1
Recoil
Recoil
Recoil
5000W
4000W
6000W
5000W
9000W
8000W
120/240VAC
120/240VAC
120/240VAC
120/240VAC
20.8
69.9
29.2/14.6
73.5
33.3/16.7
73.3
41.6/20.8
72
66.7/33.4
76.1
1650W
1400W
120VAC/
12VDC
13.7
59
3200W
2800W
120VAC/
12VDC
23.3
58
4300W
3800W
120VAC/
12VDC
31.7
62
—
2-20 AMP
—
—
3-15 AMP
—
—
—
—
2-20 AMP
1-30 AMP
1-30 AMP
—
2-20 AMP
1-30 AMP
1-30 AMP
—
2-20 AMP
1-30 AMP
1-30 AMP
—
2-20 AMP
1-30 AMP
1-30 AMP
—
2-20 AMP
—
—
—
2-20 AMP
1-30 AMP
—
—
2-20 AMP
1-30 AMP
—
4.2 qt
2.5 hr
4.2 hr
3.8 qt
1.5 hr
2.3 hr
4.6 gal
4 hr
7 hr
4.6 gal
6 hr
10 hr
4.6 gal
4 hr
7 hr
4.6 gal
3.2 hr
5.6 hr
4.2 qt
2.4 hr
4 hr
3.7 gal
5 hr
8.4 hr
4.2 gal
3.9 hr
6.6 hr
19.3”
11.6”
17.5”
55 lbs
22”
15.75”
16.5”
94 lbs
28”
20.5”
22.25”
162 lbs
28”
20.5”
22.25”
162 lbs
28”
20.5”
22.25”
187/193 lbs
28”
21.50”
21.0”
217 lbs
19.3”
11.6”
17.5”
45 lbs
21"
18.9"
22.9"
130 lbs
22.8"
20.7"
24.3"
143 lbs
PC60HE
NOTES: 1 Batteries are not included on any Electric Start Models.
2 Inverter generator.
Three Phase is available on 5 kW and up. Excludes PCM90VE. Contact your local Baldor District Office. See options on page 3.
Baldor reserves the right to implement specifications or design changes without notice.
WARNING: Do not connect generator to any building’s electrical system unless a disconnect switch has been installed.
Follow local and national electrical codes for proper installation.
5
Diesel Industrial Portable Generators
Baldor’s diesel portables feature the rugged Hatz diesel engine, known worldwide as a superior air-cooled diesel engine.
Baldor generators are manufactured to exceed industrial specifications using high quality components.
• Electric Start
• Brushless Alternator
• Hour Meter (diesels) – Helps to track and schedule routine maintenance
• Voltage-120/240 Volt Single Phase
• Wheel Kit- Available as accessory
Diesel Industrial Portable Generators
Designed to operate on diesel fuel. Provides auxiliary power for many applications where
diesel fuel is available. Suitable for commercial, construction, and farm applications.
DG6E
Catalog
Number 1
Max.
Watts
Cont.
Watts
Fuel
Capacity
Engine
Engine
Hp
Volts
DG3E
DG6E
3300
6000
3000
5500
2.75 Gal.
4.6 Gal.
Hatz
Hatz
5.5
9.9
120/240 VAC
120/240 VAC
1 Batteries are not included or available on any Electric Start Models.
Baldor reserves the right to implement specifications or design changes without notice.
WARNING: Do not connect generator to any building’s electrical system unless a disconnect switch has been installed.
Follow local and national electrical codes for proper installation.
NOTES:
Receptacles
6
List
Price
$3582
4995
Mult.
Sym.
PG
PG
Approx.
Shipping
Wgt. (lbs)
175
254
Baldor Industrial Portable Generators
Portable Diesel Model
DG3E
DG6E
Switchless Full Pow’R
std
std
AC Voltmeter
std
std
Hourmeter
std
std
AC Circuit Breakers
—
—
Low Oil Shutdown
std
std
Spark Arrestor Muffler
std
std
Extended Run Fuel Tank
std
std
Tubular Roll Cage
std
std
Neoprene Isolators
std
std
Focal Vibration System
std
std
3-Year Warranty
std
std
Engine Model
Hatz 1B30
Hatz 1B40
5.5
9.9
Features
Horsepower
Cylinder
1
1
346
461.9
12 Volt with Recoil 1
12 Volt with Recoil 1
Max Rating
3300
6000
Rated
3000
5500
Volts
120/240 VAC
120/240 VAC
Amps
25/12.5
45.8/22.9
—
—
Straight (520R GFCI) 120V
2-20 AMP
4-20 AMP
Twist Lock (L530R) 120V
1-30 AMP
1-30 AMP
Twist Lock (L1430R) 120/240V
—
1-30 AMP
Twist Lock (L1420R) 120/240V
1-20 AMP
—
Displacement - CC
Starting Systems
Rating
dBA @ 7 meters
Receptacles
Fuel System
Fuel Capacity (U.S. Gallons)
2.75
4.6
Operational Run Time/Full Load
5.4 hr
4.6 hr
Operational Run Time/Half Load
9 hr
6 hr
Dimensions
Length
24.5”
32”
Width
18.5”
20.5”
Height
21.75”
23.75”
Weight (Net Dry)
172 lbs
246 lbs
NOTES:
1 Batteries are not included or available on any Electric Start Models.
Baldor reserves the right to implement specifications or design changes without notice.
WARNING: Do not connect generator to any building’s electrical system unless a disconnect switch has been installed.
Follow local and national electrical codes for proper installation.
7
7
Industrial Towable Generators
Applications
Industrial towable generators are designed and engineered for
optimum performance and superior reliability. From the ultra quiet
sound attenuated enclosures (64-71 dBA) to the state-of-the-art
electronics and controls, these units are engineered to meet the
most rugged conditions. Place the unit at the job site, connect the
load and start it up. These full-featured units are specially suited for
all industrial, commercial and rental applications. Units can also be
used with an automatic transfer switch for standby applications.
Towables are available from 25KVA/20 kW - 250 KVA/200 kW.
TS80T
Standard Features
• Large Integral Fuel Tank.
• High Water Temperature Shutdown.
• Low Oil Pressure Shutdown.
• Overspeed Shutdown.
• Overcrank Lockout.
• Full Featured Control Panel.
• Extra Large Access Doors.
• Battery Included.
• Fuel Water Separators.
• Manual or Automatic Start.
• Voltage Selections – Three-position switch
No reconnection required.
• Single Point Lifting Eye.
• Available with or without the trailer.
Additional Features for TS250 Only
• 24 hour sub base double wall tank.
• Electronic Governor.
• Low coolant/Low fuel level shutdown.
• Digital Controller.
• Alarm horn with silencer.
• Emergency Stop.
Industrial Standby
(with or without trailer)
Catalog
Number
KVA/kW
@ 240V
1 Phase
KVA/kW
@ 208/240
3 Phase
KVA/kW
@ 480V
3 Phase
TS25T
TS45T
TS80T
TS130T
TS175T
TS250T
18/18
27/27
45/45
70/70
80/80
175/175
25/20
46/37
72/58
131/105
169/135
250/200
25/20
48/38
81/65
134/107
175/140
250/200
TS25S
TS45S
TS80S
TS130S
TS175S
TS250S
18/18
27/27
45/45
70/70
80/80
175/175
25/20
46/37
72/58
131/105
169/135
250/200
25/20
48/38
81/65
134/107
175/140
250/200
VAC
1 Phase
VAC
3 Phase
Engine*
With Trailer
120/240
208/240/480
Isuzu
120/240
208/240/480 John Deere
120/240
208/240/480 John Deere
120/240
208/240/480 John Deere
120/240
208/240/480 John Deere
120/240
208/240/480 John Deere
Skid Mount Without Trailer
120/240
208/240/480
Isuzu
120/240
208/240/480 John Deere
120/240
208/240/480 John Deere
120/240
208/240/480 John Deere
120/240
208/240/480 John Deere
120/240
208/240/480 John Deere
Fuel
Capacity
List
Price
Mult.
Sym.
Approx.
Shipping
Wgt. (lbs)
50 Gal.
80 Gal.
80 Gal.
160 Gal.
160 Gal.
260 Gal.
$21211
30285
35946
56221
63637
92647
TG
TG
TG
TG
TG
TG
2265
3540
3848
5600
6200
8900
50 Gal.
80 Gal.
80 Gal.
160 Gal.
160 Gal.
260 Gal.
20459
28032
33142
53940
60404
88716
TG
TG
TG
TG
TG
TG
1790
2829
3053
4610
5205
7350
NOTE: “S” suffix – skid mount, no trailer; “T” suffix – with trailer.
Baldor reserves the right to implement specifications or design changes without notice.
* TS25, TS45 and TS250 units have Tier 2 emissions ratings.
Towable
Options
AC Batt. Chgr.
8
Features
Catalog
Number
Available
for Models
List
Price
Mult.
Sym.
12V, 6A Reg., Semi-Float, Ship Loose
EA0010A02SP
All Towables
$209
PP
Block Heater
Tank Type w/Thermostat
Custom
All Towables
242
GS
Hydraulic Brakes
Add on Brake for TS25T
Custom
TS25T
913
GS
Electric Brakes
Add on Brake for TS25T
Custom
TS25T
746
GS
Electric Brakes
Change Standard Hydraulic Brake
to Electric Brake
Custom
TS45T, TS80T, TS130T.
TS175T, TS250T
50
GS
Electronic Governor
Provides excellent frequency regulation
Custom
TS25
544
GS
Electronic Governor
Provides excellent frequency regulation
Custom
TS45 – TS175
1163
GS
2" Ball Hitch
Change from Standard 3" Pintle to Ball
TY1004A01SP
All Towables
N/C
PP
2-5/16" Ball Hitch
Change from Standard 3" Pintle to Ball
TY1004A02SP
All Towables
N/C
PP
Baldor Towable Generators
Model
Engine
Standby Output - 150°C Rise
3 ph @ 480 Volt
3 ph @ 208 or 240 Volt Volt
1 ph @ 240 Volt
Prime Output - 125°C Rise
3 ph @ 480 Volt
3 ph @ 208 or 240 Volt
1 ph @ 240 Volt
Voltage Selections
Voltage - 3 ph Adjustable
Voltage - 1 ph Adjustable
3-Phase Power Factor
Voltage Regulation
Frequency 4
Total Harmonic Distortion
Insulation Material
Amperage (Continuous):
3 ph 480 Volt
3 ph 208 Volt
3 ph 240 Volt
Single phase amperage @ 240V/120V
Engine Specifications
Model
Cylinders
TS25T/S
Isuzu
TS45T/S
John Deere
TS80T/S
John Deere
25/20
25/20
18/18
48/38
46/37
27/27
81/65
72/58
45/45
23/18
23/18
18/18
44/35
44/35
25/25
75/60
69/55
43/43
TS130T/S
John Deere
(KVA/kW)
134/107
131/105
70/70
(KVA/kW)
121/97
119/95
66/66
208/220/240
208/220/240
208/220/240
208/220/240
416/440/460/480 416/440/460/480 416/440/460/480 416/440/460/480
120/127/139
120/127/139
120/127/139
120/127/139
240/254/277
240/254/277
240/254/277
240/254/277
0.8
0.8
0.8
0.8
1/2%
1/2%
1/2%
1/2%
60 Hz.
60 Hz.
60 Hz.
60 Hz.
<5%
<5%
<5%
<5%
Class H
Class H
Class H
Class H
TS175T/S
John Deere
TS250T/S
John Deere
175/140
169/135
100/100
250/200
250/200
175/175
159/127
156/125
95/95
227/180
227/180
160/160
208/220/240
416/440/460/480
120/127/139
240/254/277
0.8
1/2%
60 Hz.
<5%
Class H
208/220/240
416/440/460/480
120/127/139
240/254/277
0.8
1/2%
60 Hz
<5%
Class H
27.1
62.5
54.1
75.0/150.0
52.6
121.4
105.3
104.2/208.3
90.2
190.8
165.4
179.2/358.3
145.8
329.6
285.7
275/550
203.0
433.7
375.9
312.5/625
277
637
555
361/722
4LE
4
5030TF270
5
T04045T
4
T06068
6
RG6081T
6
Induction System
Nat Aspirated
Turbocharged
Turbocharged
Turbocharged
Turbocharged
Displacement, Liter/Cu. In.
Hp @ Rated Speed
RPM
Bore and Stroke 3.4 x 4.1
Oil capacity (with filter)
Cooling
Battery, Rack and Cable Supplied
Battery Minimum Cold Cranking Amps
Receptacle Specifications
120 Volt 20 Amp Duplex GFCI
120/240 Volt 50 Amp CS6369 Twistlock
Two Wire Remote Start Capability
Fuel System Specifications (Diesel)
Fuel Consumption GPH – 1/2 load/(full load)
Approximate Run Time (Hours) 1/2 load/(full load)
Fuel Capacity (Ga.)
Capacity and Dimensions
Sound Level dBA @ 7 meters, full load
Dimensions (LxWxH) with trailer
Dimensions (LxWxH) without trailer
Weight without Fuel (lb)
Weight without Fuel and without Trailer (lb)
2.2/133
34.5
1800
3.34” x 3.78”
8.6 quarts
Liquid
3.0/186
64
1800
4.13” x 4.92”
11.8 quarts
Liquid
4.5/276
100
1800
4.19” x 5.0”
14 quarts
Liquid
6.8/414
166
1800
4.19” x 5.0”
18 quarts
Liquid
8.1/496
211
1800
4.56” x 5.06”
33 quarts
Liquid
6068HF475
6
Turbocharged
Intercooled
6.8/415
314
1800
4.19 x 5.00
34 quarts
Liquid
750
900
900
2X 750
2X 750
2X 800
2
2
std
3
3
std
3
3
std
4
4
std
4
4
std
4
4
std
1.3/(2.0)
38/(25)
50
2.0/(3.4)
40/(24)
80
2.7/(4.9)
30/(16)
80
4.2/(8.1)
38/(20)
160
5.6/(10.5)
29/(15)
160
7.6/(15.2)
34 (17)
260
64
131” x 62” x 72”
74” x 38” x 52”
2265
1790
67
147” x 62” x 85”
84” x 38” x 61”
3540
2829
67
147” x 62” x 85”
84” x 38” x 61”
3848
3053
71
180” x 69” x 94”
108” x 42” x 74”
5600
4610
71
180” x 69” x 94”
108” x 42” x 74”
6200
5205
67
218" x 80" x 102"
159" x 54" x 76"
8900
7350
NOTES: Engine, Generator Instrumentation – Voltmeter, ammeter, frequency meter, phase selector switch, oil pressure gauge, water temp gauge, battery voltmeter, start/
stop/auto switch, voltage adjusting rheostat, hour meter, individual fault shutdown lights, panel lights with switch, receptacle panel. TS250 includes low coolant level
shutdown, low fuel level shutdown, alarm horn w/silencer and emergency stop.
Standby Rating for supplying emergency power for the duration of a utility power outage.
No overload capability for standby rating. Standby ratings in accordance with ISO 3046, BS55114, DIN 6271.
4 50 Hz available as custom
Baldor reserves the right to implement specifications or design changes without notice.
WARNING: Do not connect generator to any building’s electrical system unless a disconnect switch has been installed.
Follow local and national electrical codes for proper installation.
9
Baldor POW’R LITE Mobile Light Tower
Baldor’s compact mobile light tower provides 4000
watts of light anywhere you need it. With metalhalide lamps the Baldor POW’R LITE models will
provide light coverage for over 7 acres. Each
model is powered by a Baldor 6000-watt light tower
generator which are designed for a compact and
efficient installation. POW’R LITE light towers are
powered by the dependable Kubota and Lombardini
diesel engines. A 30-gallon fuel tank provides for
60-hours of operation. The Baldor POW’R LITE
light towers can be used for various types of
applications: Construction, Emergency, Industrial,
Mining, Civil Engineering and Event Lighting.
Features:
• 4 Powerful 1000 Watt metal halide lamps.
• Elliptical light fixtures provide a more efficient light pattern than conventional
round fixtures. The 4 – 1000 Watt metal halide lamps are supported on both
ends to enhance durability and long life.
• 2000 watts for convenience outlets.
• One 120-volt GFI convenience receptacle and one 240-volt twist-lock receptacle.
• Quiet, dependable Kubota or Lombardini diesel engine provides “flicker-free” operation.
• Sturdy construction with heavy gauge powder coated steel.
• Zinc plated 30’ 4-section mast, coiled mast cords.
• Tower rotates 360 degrees
• Heavy-duty winch design and integral forklift pockets.
• 30-gallon fuel tank – up to 60 hours of running time.
• Quality highway trailer suspension.
• Low oil/high temperature shutdown protection.
• Hour meter and DC voltmeter.
• Battery included.
Catalog
Number
Max. Watts
Mast
Height
Fuel
Capacity
Engine
Engine
Hp
Lighting
Type
List Price
Mult. Sym.
Weight (lbs)*
PL6000K
6000
30
30 gal.
Kubota
11.9
Metal Halide
$12819
LT
1700
PL6000L
6000
30
30 gal.
Lombardini
13.6
Metal Halide
12229
LT
1700
NOTES: * 53-foot flatbed easily holds 10 compact units.
10
Baldor Mobile Light Towers
POW’R LITE Light Tower
Engine / Generator
Engine
Engine Type
Engine HP
Fuel tank capacity (Gal.)
Run time 1-Tankful
Sound Level
Generator Manufacturer
Generator Model
6kW Generator
Low Oil Shutdown
High Temp Shutdown
Hour meter
DC Voltmeter
12V Battery
Mast / Enclosure
Mast Height
Mast Material
Mast sections
Tower rotation
Mast Cord
Electric winch for tower
Enclosure material
Sides
Doors
Hinge material
Finish/Coating Enclosure
Finish/Coating Hardware Tower, outriggers, jack, safety chains
Lockable Doors
Gas door struts
Fenders
Outrigger support system
Ground rod holder & cable
Forklift pockets
Lighting / Electric
Lighting Coverage
Lighting Type
PL6000L
PL6000K
LDW1003 Lombardini
Diesel, 3 Cyl., Nat. Asp. 916 cc
13.6
D905 Kubota
Diesel, 3 Cyl., Nat. Asp. 898 cc
11.9
Lamp Fixture Materials
Ballasts
Quick Disconnect Lights
Receptacles at panel
Control Panel
Individual Lamp Switches
Trailer
Standard Hitch (Removable)
Trailer Lights
Transport tie-downs
Tires
Towing speed (MPH)
Height stowed
Length stowed
Width stowed
Weight – Dry (Lbs)
30
60 (Hours)
72dBA
Baldor
30.00115
Std
Std
Std
Std
Std
Std
30'
Zinc Plated
4
360 Deg
Coiled
Optional
10 Gauge
12 Gauge
Aluminum
Powder Coat
Zinc Plated
Std
Optional
Steel
3 Point
Optional
Std
5-7 Acres
4/1000W Metal Halide
Spider Bulb Support
Tempered Glass Bulb Lens
Core & Coil "Easy Access"
Option
1/120V GFI 20 AMP Duplex
1/30 Amp Twist Lock 240V
Internal
Std
2" Ball
Std
Std
14"
55
63"
152"
54"
1700
NOTE: Baldor reserves the right to implement specifications or design changes without notice.
11
Options - Light Towers
Catalog
Number
List Adder
2” Pintle
TY5008A21SP
N/C
3” Pintle
TY5008A20SP
$63
Custom
69
POW'R LITE Options
*Additional 120V Receptacles
TY5008A31SP
135
*Fuel Water Separator
Custom
243
*Gas Door Struts (set of 2)
Custom
175
Fire Extinguisher
Ground Rod w/Cable
TY5008A03SP
75
Combination Dual hitch
TY5008A04SP
114
Custom
241
*Electric Winch (for tower)
*Sound Attenuation
Custom
406
Spare Tire & Rim (mounted)
TY5008A08SP
435
Dome Light
TY5008A09SP
33
Complete Light Fixture w/o bulb
TY5008A10SP
549
Complete Light Fixture with bulb
TY5008A11SP
642
Metal Halide Bulb (each)
TY5008A12SP
134
Metal Halide Bulb (sold in case of six)
TY5008A33SP
685
Lens – Glass & Gasket
TY5008A13SP
115
Jack
TY5008A14SP
115
Lombardini Air Filter
EA0014A73SP
60
Lombardini Oil Filter
EA0003A31SP
56
Lombardini Fuel Filter
EA0014A74SP
55
Kubota Air Filter
EA0014A75SP
112
Kubota Oil Filter
EA0003A32SP
19
Kubota Fuel Filter
EA0014A76SP
18
Ballast
TY5008A15SP
322
Capacitor/Lighting
TY5008A16SP
72
Lighting Ballast/Cap Set 120V
TY5008A17SP
362
Quick Disconnects (Maie) – 4 Lights
TY5008A18SP
267
Quick Disconnects (Female) – 4 Lights
TY5008A19SP
267
Wiring Harness Ballast Box to Control Box
LD6205A68SP
191
Renewal Parts
* Custom (Factory Installed) – Contact Baldor District Office.
12
DLC (Diesel Liquid Cooled)
Industrial Agricultural
Standby Generators
Applications
Diesel engine-driven generator systems for industrial and
agricultural applications including confinement house
operations, dairy farms, and greenhouse facilities. Used also
as backup power systems for municipality services such as
water treatment plants. Rugged and reliable, these units are
designed for use in many applications requiring a standby
power supply.
DLC125-JD
Features
• All DLC generators are prototype tested, factory built and production tested.
• Ratings from 30 kW to 200 kW. (Larger diesel ratings available – see box below.)
• Available options - 100-600 amp NEMA 1/NEMA 3R Automatic Transfer Switches, weather enclosures, sub base tanks
and circuit breaker. Contact local office for information.
• 12V DC electric start.
• 100% full load tested for 100% block loading.
• John Deere industrial diesel engine.
• Full status monitor provides system monitoring of low oil pressure, high coolant temperature, overspeed and overcrank.
• Direct fuel line connections for use with existing tanks or optional sub-base tank. Optional flexible fuel lines available
• 1800 RPM, 60 HZ, single phase, 4 lead generators.
• Alternators are efficient brushless synchronous four-pole construction, dynamically balanced with double sealed
prelubricated ball bearings.
• World-wide network of parts and service centers.
DLC Industrial Generators
Kilowatt (kW)
Rating
Engine
Engine
Hp
Volts1
List
Price
Mult.
Sym.
Approx.
Shipping
Weight (lbs)
DLC30-JD
30
John Deere
71
120/240 VAC
$12387
AG
1465
DLC50-JD
50
John Deere
100
120/240 VAC
14039
AG
1601
DLC60-JD
60
John Deere
100
120/240 VAC
16184
AG
1753
Catalog
Number
DLC75-JD
75
John Deere
110
120/240 VAC
17039
AG
1838
DLC100-JD
100
John Deere
165
120/240 VAC
21362
AG
2045
DLC125-JD
125
John Deere
190
120/240 VAC
25107
AG
2652
DLC150-JD
150
John Deere
251
120/240 VAC
29772
AG
2652
DLC200-JD
200
John Deere
300
120/240 VAC
34365
AG
3875
NOTE:
1 Single phase voltage. Contact District Office for 3 Phase engineered IDLC product.
Batteries are not included. See page 15 for option adder.
Baldor reserves the right to implement specifications or design changes without notice.
IDLC CUSTOM RATINGS AVAILABLE!
Baldor Generators offers industrial diesel generators up to 2 MW. These units are available with various
enclosures, features and options. ISO container enclosures are available in 20 or 40 ft. sizes and can be
designed for Standby/Prime installations. Consult your Baldor District Office for more information.
13
DLC (Diesel Liquid Cooled)
Model 1
DLC Generator w/Industrial Grade Silencer,
ECU Controller, Battery Rack and
Cables, Engine Block Heater – List Price
Engine
Engine Horsepower
DLC30-JD DLC50-JD DLC60-JD DLC75-JD
DLC100-JD
DLC125-JD
DLC150-JD
DLC200-JD
$12,387
$14,039
$16,184
$17,039
$21,362
$25,107
$29,772
$34,365
John Deere
4045DF150
71
John Deere
4045TF150
100
John Deere
4045TF150
100
John Deere
4045TF250
110
John Deere
6068TF150
165
John Deere
6068TF250
190
John Deere
6068HF150
251
John Deere
RG6081AF001
300
Options and Accessories List Price
DLC30-JD
DLC50-JD
DL 60-JD
DLC75-JD
$2984
$2984
$2984
$3241
$3241
Critical Grade (Ship Loose)
358
358
358
427
Exhaust Flex (Ship Loose)
Fuel System
97
97
97
97
Flexible Fuel Lines
Single Wall Sub-Base Fuel Tank
90
90
90
Model 1
DLC100-JD DLC125-JD
DLC150-JD
DLC200-JD
$3572
$3889
$3889
427
790
790
790
97
148
148
148
90
90
145
145
145
Enclosure Installed
Weather Protective Enclosure
(with Critical Silencer & Flex) (Mounted)
Silencer Enclosed Unit
Critical Silencer & Flex, elbow and rain cap, mounted
Silencer OPEN Unit
12 hours, 50 gallon
2118
—
—
—
—
—
—
—
12 hours, 60 gallon
—
2196
2196
—
—
—
—
—
12 hours, 80 gallon
—
—
—
2250
—
—
—
—
12 hours, 100 gallon
—
—
—
—
2262
—
—
—
12 hours, 120 gallon
—
—
—
—
—
2380
—
—
12 hours, 150 gallon
—
—
—
—
—
—
2911
—
12 hours, 210 gallon
—
—
—
—
—
—
—
3148
24 hours, 90 gallon
2262
—
—
—
2616
2616
2616
—
24 hours, 120 gallon
—
2380
2380
—
—
—
—
—
24 hours, 150 gallon
—
—
—
2911
—
—
—
—
24 hours, 200 gallon
—
—
—
—
3032
—
—
—
24 hours, 240 gallon
—
—
—
—
—
3127
—
—
24 hours, 300 gallon
—
—
—
—
—
—
3304
—
24 hours, 420 gallon
Double Wall UL-142 Sub-Base Tank
—
—
—
—
—
—
—
3724
12 hours, 50 gallon
2322
—
—
—
—
—
—
—
12 hours, 60 gallon
—
2401
2401
—
—
—
—
—
12 hours, 80 gallon
—
—
—
2674
—
—
—
—
12 hours, 100 gallon
—
—
—
—
3160
—
—
—
12 hours, 120 gallon
—
—
—
3263
—
3207
—
—
12 hours, 150 gallon
—
—
—
—
—
—
3342
—
12 hours, 210 gallon
—
—
—
—
—
—
—
3438
24 hours, 90 gallon
2624
—
—
—
—
—
—
—
24 hours, 120 gallon
—
2913
2913
—
—
—
—
—
24 hours, 150 gallon
—
—
—
3206
—
—
—
—
24 hours, 200 gallon
—
—
—
—
3636
—
—
—
24 hours, 240 gallon
—
—
—
—
—
2653
—
—
24 hours, 300 gallon
—
—
—
—
—
—
3925
—
24 hours, 420 gallon
Electrical System
—
—
—
—
—
—
—
4116
EA0010A02SP 6 A. Batt. Charger (Float/EQ)
208
208
208
208
208
208
208
208
EA0006A17 10 A. Batt. Charger (Float/EQ)
624
624
624
624
624
624
624
624
80 Watt Battery Heater
246
246
246
246
246
246
246
246
Alternator Space Heater
348
348
348
348
348
348
348
348
NOTES: 1 Single Phase voltage output on these models.
Batteries ship loose on open units (see option adder)
Baldor reserves the right to implement specifications or design changes without notice.
14
DLC Options and Accessories List Price (continued)
DLC30-JD DLC50-JD DL 60-JD
Model 1
Square D Circuit Breakers – 2 or 3 Pole, Installed – 80% Rated Thermal Magnetic
DLC75-JD
DLC100-JD DLC125-JD
DLC150-JD
DLC200-JD
3 Pole, 60 Amp
$512
—
—
—
—
—
—
—
3 Pole, 90 Amp
—
$573
—
—
—
—
—
—
3 Pole, 100 Amp
575
—
$523
—
—
—
—
—
3 Pole, 125 Amp
1004
—
—
—
—
—
—
—
2 Pole, 150 Amp (1 Ph only)
385
—
—
—
—
—
—
—
3 Pole, 150 Amp
—
—
—
$1004
—
—
—
—
3 Pole, 175 Amp
—
1004
—
—
$1004
—
—
—
3 Pole, 200 Amp
—
1004
—
—
—
—
—
—
3 Pole, 225 Amp
—
—
1004
—
—
$1004
—
—
2 Pole, 250 Amp (1 Ph only)
—
1172
—
—
—
—
—
—
3 Pole, 250 Amp
—
—
1511
1511
—
—
—
—
2 Pole, 300 Amp (1 Ph only)
—
—
1172
—
—
—
$1511
—
3 Pole, 300 Amp
—
—
—
1594
—
—
—
—
2 Pole, 350 Amp (1 Ph only)
—
—
—
1172
—
—
—
—
3 Pole, 350 Amp
—
—
—
—
1594
—
—
—
3 Pole, 400 Amp
—
—
—
—
1594
—
—
$1172
3 Pole, 450 Amp
—
—
—
—
—
2131
—
—
2 Pole, 500 Amp (1 Ph only)
—
—
—
—
1742
—
—
—
3 Pole, 500 Amp
—
—
—
—
—
2131
2131
—
2 Pole, 600 Amp (1 Ph only)
—
—
—
—
—
2169
—
—
3 Pole, 600 Amp
—
—
—
—
—
—
2131
—
3 Pole, 700 Amp
—
—
—
—
—
—
—
2706
2 Pole, 800 Amp (1 Ph only)
—
—
—
—
—
—
2169
—
3 Pole, 800 Amp
—
—
—
—
—
—
—
2706
2 Pole, 1000 Amp (1 Ph only)
Controller Accessories and Batteries
—
—
—
—
—
—
—
2969
Electronic (Isochronous) Governor w/o speed adjust
544
544
544
544
544
1163
1163
1163
Battery – 30H Style 12V – 680CCA
136
136
136
136
136
136
136
136
Battery – 31-900CT 12V – 900CCA
Miscellaneous
205
205
205
205
205
205
205
205
Additional Operator & Maintenance Manuals
129
129
129
129
129
129
129
129
NOTES: 1 Single Phase voltage output on these models. Three-phase alternators available as IDLC models. Contact local Baldor District Office for additional information.
Batteries ship loose on open units
Baldor reserves the right to implement specifications or design changes without notice.
15
Automatic Emergency (AE)
Standby Generators
Applications
The Automatic Emergency (AE) generators have been engineered
and built to meet the emergency power needs of residential and
commercial customers. The generators may be operated in manual or
automatic mode and all models run on either natural gas or propane
(LP). Baldor Automatic Emergency generators offer peace of mind
when utility power is not available.
AE11-E
Features
The Automatic Emergency product line has models ranging from 8-25kW. When used with an automatic transfer switch,
these units continuously monitor the electrical voltage and start up automatically if the utility power supply is interrupted,
and then shut themselves off when utility service is returned.
• Natural Gas/LP units are available.
• Attractive Design – Aesthetically pleasing after installation.
• Fully Automatic System – When connected to an Automatic Transfer Switch.
• Convenient Fuel Source – Runs on your existing fuel supply (NG/LP).
• Powder Coat Paint Finish – State-of-the art painting system ensures long and beautiful enclosure life.
• Dual Side Serviceability – Provides ease of maintenance.
• Advanced Noise Technology – Weatherproof enclosure is constructed of heavy gauge steel and has special sound
insulation to reduce operating noise (69-73 dBA).
• Operational Efficiency – All engines are direct coupled to high efficiency brushless generators for dependable operation
when needed.
• World-class components backed by a world-wide network of parts and service.
Automatic Emergency
Catalog
Number 1
Max. kW
LP
Max kW
Nat. Gas
Engine
Engine
Hp
Volts
List
Price
Mult.
Sym.
Approx.
Weight (lbs)
AE8-E
8
7.2
Vanguard
16
120/240 VAC
$5829
AE
463
AE10-E
10
9
Vanguard
18
120/240 VAC
7589
AE
509
AE11-E
11
10.5
Kohler
23
120/240 VAC
8240
AE
556
AE25-E-NG
–
22.5
Ford
40
120/240 VAC
18735
AE
1450
AE25-E-LP
25
–
Ford
40
120/240 VAC
18735
AE
1450
NOTES:
Batteries are not included on any Electric Start Models. See page 17 for option adder.
1 Two Amp semi float charger included for AE8, AE10 and AE11. Six Amp semi float charger is included with the AE25
Please add applicable automatic transfer switch to unit price. See options. All models are electric start.
WARNING:
16
Baldor reserves the right to implement specifications or design changes without notice.
Do not connect generator to any building’s electrical system unless a disconnect switch has been installed.
Follow local and national electrical codes for proper installation.
A licensed installer should perform installation.
Baldor Automatic Emergency (AE) Generators
Model
Engine
Rating (60 Hz) 1
Fuel
Voltage (1 Phase)2
Power Factor
Amps – 120V (240V)
Voltage Regulation (1 & 3 Phase)
Frequency Regulation (1 & 3 Phase)
Engine Specifications
Model
Horsepower
Cylinders
Cycle
Induction System
Displacement, CC (cu.in.)
Displacement, L (cu.in.)
Oil capacity (with filter)
Cooling
Battery recommendation (min cold cranking amps)
Fuel Consumption
LP Gas
Natural Gas
Alternator Specifications
Manufacturer
Type
Leads
Voltage Regulator
Voltage Regulation
Insulation Material
Temperature Rise
One Step load Acceptance
Control Features
Low oil pressure & overcrank
Shutdown with indicator lights
Circuit breaker protection
Remote start-stop connection
Engine Features
Spin-on oil filter
Electronic governor
12V starter (battery not included)
Sound level dBA @ 7 meters, full load
Dimensions (LxWxH) w/enclosure
Weight
AE8
Vanguard
8kW/7.2kW
LP/NG
120/240
1
66.8 (33.4)
± 5%
± 5%
AE10
Vanguard
10kW/9kW
LP/NG
120/240
1
83.4 (41.7)
± 1%
± 5%
AE11
Kohler
11kW/10.5kW
LP/NG
120/240
1
91.6 (45.8)
± 1%
± 5%
AE25 (NG/LP)
Ford
25kW/22.5kW
LP/NG
120/240
1
208.4 (104.2)
± 1%
± 1%
303447
16
2
4-stroke
Naturally aspirated
480 (29.3)
350447
18
2
4-stroke
Naturally aspirated
570 (34.8)
CH23GS
23
2
4-stroke
Naturally aspirated
725 (44.0)
LRG-425
40
4 in-line
4-stroke
Naturally aspirated
3.5 pints
Air
300
3.5pints
Air
300
2 quarts
Air
300
2.5L (153 cu. in.)
4.5 quarts
Liquid
680
64 C.F.H.
160 C.F.H.
72 C.F.H.
200 C.F.H.
108 C.F.H.
209 C.F.H.
143 C.F.H.
419 C.F.H.
Baldor
2p/revolving field
4
Capacitor
1/2%
Class F
150°C
100% of Rating
Baldor
2p/revolving field
4
AVR
1/2%
Class F
150°C
100% of Rating
Baldor
2p/revolving field
4
AVR
1/2%
Class F
150°C
100% of Rating
Baldor
4p/revolving field
4
AVR
1/2%
Class F
150°C
100% of Rating
std
std
1
std
std
std
1
std
std
std
1
std
std
std
1/3
std
std
—
std
71
44.5x29x36.75
445 lbs
std
—
std
70
44.5x29x36.75
445 lbs
std
—
std
73
46x30.375x30.5
556 lbs
std
std
std
69
72x31.5x34
1345 lbs
1 Standby Ratings: applicable for supplying emergency power for the duration of a utility power outage. No overload capability for standby rating.
Standby ratings in accordance with ISO 3046, BS55114, DIN 6271.
2 AE10, AE11, AE25 available in three phase. Consult your Baldor District Office for details.
Single phase units are rated at 1.0 (unity) power factor.
Baldor reserves the right to implement specifications or design changes without notice.
WARNING: Do not connect generator to any building’s electrical system unless a disconnect switch has been installed.
Follow local and national electrical codes for proper installation.
NOTES:
Automatic Emergency Standby Generators Options and Accessories
Catalog Number
EA0010A02SP
Custom *
Option
AC Battery Charger, 12 Volt, 6 amp, Regulated, Semi-Float, Shipped Loose
Water Jacket Heater
Battery
SP40 – 340CCA
Battery
30H Style 12V – 680CCA
Available for Models
List Price
AE8, AE10, AE11
$208
AE25-E
312
AE8, AE10, AE11
151
AE25
132
* Custom order – Consult your local Baldor District Office for specifications and delivery.
17
GLC (Gaseous Liquid Cooled)
Industrial Standby Generators
Applications
The Baldor GLC product line operates on Natural Gas or LP gas and
provides reliable standby power for industrial and commercial including
telecommunications, banking, medical, nursing homes, schools, etc.
applications. Baldor GLC power generation systems are available in
open configuration, weather protective and fully sound attenuated
enclosures. Other accessories are available to meet application
requirements. Contact your Baldor District Office for more information.
GLC80
Features
• All GLC generators are prototype tested, factory built and production tested.
• UL2200 – Available – Consult factory
• Heavy Duty Gaseous GM Industrial engine.
• Electronic governor.
• 12V DC electric start
• Solid state controls are adjustable for maximum flexibility.
• Prototype tested per NFPA 110.
• Alternators are efficient brushless synchronous four pole construction, dynamically balanced with double sealed
prelubricated ball bearings.
• A world wide network of parts and service centers.
GLC Industrial Generators
Catalog
Number
1
Kilowatt (kW)4
Rating
LP
Kilowatt (kW)4
Rating
Natural Gas
Engine
Engine
Hp3
VAC2
1 Phase
VAC2
3 Phase
List
Price
Mult.
Sym.
GLC30
30
30
GM V6 (4.3L)
64
120/240
208/240/480
$16215
GS
GLC35
35
35
GM V6 (4.3L)
64
120/240
208/240/480
16670
GS
GLC45
41
37
GM V6 (4.3L)
64
120/240
208/240/480
18215
GS
GLC50
50
50
GM V8 (5.7L)
98
120/240
208/240/480
19640
GS
GLC60
60
54
GM V8 (5.7L)
98
120/240
208/240/480
20529
GS
GLC80
80
80
GM V8 (8.1L)
160
120/240
208/240/480
25411
GS
GLC100
97
84
GM V8 (8.1L)
160
120/240
208/240/480
26935
GS
GLC125
125
115
GM V8 (8.1L)
198
120/240
208/240/480
33738
GS
NOTES:
1 Batteries not included on any electric start models. See page 19 for option adder.
2 Specify Single or Three Phase voltage when ordering. For ratings and voltages not listed above consult your District Office.
E Natural Gas
4 150˚C Standby Rating @ 480V - 3 Phase. UL 2200 units are 125˚C standby rating.
“Quick Ship” – Allow 10 assembly days from date of order for modified units.
Baldor reserves the right to implement specifications or design changes without notice.
Baldor Generators offers industrial natural gas generators up to 875kW. These units are available with
various enclosures, features and options. Consult your Baldor District Office for more information.
18
GLC
(Natural Gas or LP)
Model
Engine
GLC Generator w/Industrial Grade Silencer, (Ship loose),
MEC2 Digital Controller, Battery Rack & Cables, Run
Relay, Electronic (Isochronous) Governor – List Price
GLC30
GLC35
GLC45
GLC50
GLC60
GLC80 GLC100 GLC125
GM 4.3L GM 4.3L GM 4.3L GM 5.7L GM 5.7L GM 8.1L GM 8.1L GM 8.1L
$16,215 $16,670 $18,215 $19,640
$20,529 $25,411
$26,935 $33,738
Options and Accessories List Price
Part No.
Description
GLC30
Enclosure Installed
Weather-Protective Enclosure with critical grade
Custom
Silencer (external roof mount) & flex, exhaust, elbow
$2771
and rain cap
Sound Attenuated Enclosure with critical grade
Custom
5371
Silencer (internal mount) & flex
Silencer OPEN Unit
Custom
Industrial Grade (Ship Loose)
221
Custom
Critical Grade (Ship Loose)
396
Custom
Exhaust Flex (Ship Loose)
97
Cooling System
1500 Watt Block Heater – GLC 30, 35 and 45
Custom
275
1800 Watt GLC 50, 60, 80, 100, 125
Custom
Radiator Duct Flange (Open Units Only)
126
Fuel System
Custom
Flexible Fuel Lines
90
Custom
Fuel Strainer (Natural Gas Units)
53
Electrical System
EA0010A02SP 6 Amp Battery Charger (Float/EQ)
208
EA0006A17
10 Amp Battery Charger (Float/EQ)
624
Custom
80 Watt Battery Heater
246
Custom
Alternate Space Heater
348
BT0009A01
209
Battery Group 31-925 CCA 1
Circuit Breakers – Installed 3-Pole, Neutral Kit
CK5017A00
60 Amp Main Line
745
CK5013A00
70 Amp Main Line
—
CK5012A00
80 Amp Main Line
—
CK5016A00
90 Amp Main Line
—
CK5001A00
100 Amp Main Line
788
CK5015A00
125 Amp Main Line
1104
CK5002A00
150 Amp Main Line
1123
CK5014A00
175 Amp Main Line
—
CK5008A00
200 Amp Main Line
—
CK5005A00
225 Amp Main Line
—
CK5006A00
250 Amp Main Line
—
CK5007A00
300 Amp Main Line
—
CK5004A00
350 Amp Main Line
—
CK5003A00
400 Amp Main Line
—
CK5010A00
450 Amp Main Line
—
CK5011A00
500 Amp Main Line
—
CK5009A00
600 Amp Main Line
—
Accessories
Custom
Analog Control Panels (ECU pre-alarms not available)
335
Remote Alarm Annunciator
896
EB2017A00 2
(EAP110, for digital controller only)
Custom
PMG Exciter
941
Custom
E-Stop Switch
383
Custom
MEC20 Controller
484
UL2200/C UL
879
Custom 3
Custom
Additional Operator & Maintenance Manuals
129
GLC35
GLC45
GLC50
GLC60
GLC80
GLC100
GLC125
$2771
$2771
$2771
$2771
$3223
$3223
$3223
5371
5371
6626
6767
6767
6767
6767
221
396
97
221
396
97
221
396
97
221
396
97
339
474
97
339
474
148
339
474
148
275
275
275
275
329
329
329
126
126
126
126
170
170
170
90
53
90
53
90
53
90
53
90
53
145
53
145
53
208
624
246
348
209
208
624
246
348
209
208
624
246
348
209
208
624
246
348
209
208
624
246
348
209
208
624
246
348
209
208
624
246
348
209
—
780
—
—
—
1104
1123
1257
—
—
—
—
—
—
—
—
—
—
—
780
—
—
—
1123
1257
—
1257
—
—
—
—
—
—
—
—
—
—
780
—
—
—
1257
1257
—
1492
—
—
—
—
—
—
—
—
—
—
788
—
—
—
—
1257
1492
2190
—
—
—
—
—
—
—
—
—
—
—
1123
—
—
—
—
2190
2190
2190
—
—
—
—
—
—
—
—
—
—
1257
—
—
—
—
2190
2190
—
3111
—
—
—
—
—
—
—
—
—
—
1257
—
—
—
—
3111
3111
3527
335
335
335
335
335
335
335
896
896
896
896
896
896
896
941
383
484
879
129
941
383
484
879
129
941
383
484
926
129
941
383
484
926
129
941
383
484
1045
129
941
383
484
1045
129
941
383
484
1087
129
NOTES: 1 Batteries ship loose on open units.
2 Remote Alarm Annunciator ships loose.
3 UL 2200 units not available with analog controls, PMG excitation or E-Stop switch. UL 2200 units must include main line breaker.
Baldor reserves the right to implement specifications or design changes without notice.
19
Transfer Switches
20
Amps
Catalog Number
100
100
100
100
100
200
200
200
200
200
400
400
400
400
400
400
400
400
600
600
600
600
800
800
800
800
95.50100
95.75100
95.50103
95.50102
95.50104
95.50200
95.75200
95.50203
95.50202
95.50204
95.50400
95.70400
95.50403
95.70402
95.50402
95.70403
95.50404
95.70404
95.70600
95.70602
95.70603
95.70604
95.70800
95.70802
95.70803
95.70804
100
100
100
100
100
200
200
200
200
200
400
400
400
400
400
400
400
400
600
600
600
600
800
800
800
800
95.50101
95.75101
95.50113
95.50112
95.50114
95.50201
95.75201
95.50213
95.50212
95.50214
95.50401
95.70401
95.50413
95.70405
95.50412
95.70406
95.50414
95.70407
95.70601
95.70605
95.70606
95.70607
95.70801
95.70805
95.70806
95.70807
Automatic Transfer Switches for Generator Sets
Mfg/Type
Volts/Connection
NEMA-1 Enclosure
Zenith ZTX
2 Pole, 240 Volt
ASCO 165
2 Pole, 240 Volt
Zenith ZTX
3 Pole, 208 Volt
Zenith ZTX
3 Pole, 240 Volt
Zenith ZTX
3 Pole, 480 Volt
Zenith ZTX
2 Pole, 240 Volt
ASCO 165
2 Pole, 240 Volt
Zenith ZTX
3 Pole, 208 Volt
Zenith ZTX
3 Pole, 240 Volt
Zenith ZTX
3 Pole, 480 Volt
Zenith ZTX
2 Pole, 240 Volt
ASCO 300
2 Pole, 240 Volt
Zenith ZTX
3 Pole, 208 Volt
ASCO 300
3 Pole, 208 Volt
Zenith ZTX
3 Pole, 240 Volt
ASCO 300
3 Pole, 240 Volt
Zenith ZTX
3 Pole, 480 Volt
ASCO 300
3 Pole, 480 Volt
ASCO 300
2 Pole, 240 Volt
ASCO 300
3 Pole, 208 Volt
ASCO 300
3 Pole, 240 Volt
ASCO 300
3 Pole, 480 Volt
ASCO 300
2 Pole, 240 Volt
ASCO 300
3 Pole, 208 Volt
ASCO 300
3 Pole, 240 Volt
ASCO 300
3 Pole, 480 Volt
NEMA-3R Enclosure
Zenith ZTX
2 Pole, 240 Volt
ASCO 165
2 Pole, 240 Volt
Zenith ZTX
3 Pole, 208 Volt
Zenith ZTX
3 Pole, 240 Volt
Zenith ZTX
3 Pole, 480 Volt
Zenith ZTX
2 Pole, 240 Volt
ASCO 165
2 Pole, 240 Volt
Zenith ZTX
3 Pole, 208 Volt
Zenith ZTX
3 Pole, 240 Volt
Zenith ZTX
3 Pole, 480 Volt
Zenith ZTX
2 Pole, 240 Volt
ASCO 300
2 Pole, 240 Volt
Zenith ZTX
3 Pole, 208 Volt
ASCO 300
3 Pole, 208 Volt
Zenith ZTX
3 Pole, 240 Volt
ASCO 300
3 Pole, 240 Volt
Zenith ZTX
3 Pole, 480 Volt
ASCO 300
3 Pole, 480 Volt
ASCO 300
2 Pole, 240 Volt
ASCO 300
3 Pole, 208 Volt
ASCO 300
3 Pole, 240 Volt
ASCO 300
3 Pole, 480 Volt
ASCO 300
2 Pole, 240 Volt
ASCO 300
3 Pole, 208 Volt
ASCO 300
3 Pole, 240 Volt
ASCO 300
3 Pole, 480 Volt
Mult. Sym.
List Price
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
982
$920
1493
1493
1493
1733
1618
2224
2224
2224
3569
2994
3748
4644
3748
4644
3748
4644
7662
7985
7985
7985
7778
8314
8314
8314
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
1097
1026
1607
1607
1607
1853
1691
2345
2345
2345
3927
3311
4105
4920
4105
4920
4105
4920
8185
8508
8508
8508
8301
8837
8837
8837
Generator Selection Guide
To determine the right size generator, add the total watts of all lights, appliances, tools or other equipment to be connected
to the generator. Undersizing of the equipment can be avoided by considering all of the loads that will be connected to the
generator and by determining the starting requirements of all electric motors. Check equipment nameplates to determine
wattage requirements. If wattage is not shown, but amps and volts are given, the following approximation may be used:
Amps x Volts = Watts
Example: 12.5 Amps x 120 Volts = 1500 Watts.
The chart shown below will help you in selecting the proper size generator. For portable electric tools and equipment,
check the nameplate rating or use the chart for average requirements. Your Baldor Generator is capable of momentarily
supplying 150% of its nameplate rating, to assist starting electric motors.
Home
Commercial
Generator
Applications
Starting Wattage
Requirements
Air Conditioner – Central
24,000 BTU
40,000 BTU
Air Conditioner – Window
10,000 BTU
24,000 BTU
Clothes Dryer
Gas
Electric
Coffee Maker
Computer
Dehumidifier
Dishwasher
Electric Range
Fan
Attic
Window
Furnace
1/6 Hp Fan
1/3 Hp Fan
Light Bulbs
Microwave Oven
625 Watt Power
850 Watt Power
Radio
Refrigerator
Sump Pump
1/3 Hp
1/4 Hp
Television
Water Heater
Well Pump
1/3 Hp
1/4 Hp
3300
7800
3000
6000
2200
7550
1750
500-1200
1450
2100-2850
1500-6000
350
100-200
1250
2100
As marked on bulb
2500
3200
50 - 200
3100
3200
2150
300
4500 per element
Generator
Applications
Starting Wattage
Requirements
Air Compressor
1/2 Hp
1 Hp
2 Hp
Drill
1/4”
3/8”
1/2”
Grinder
Bench – 8”
Hammer
Demolition
Rotary
Impact Wrench
1/2”
3/4”
1”
Pressure Washer
1 Hp
1-1/2 Hp
3 Hp
Pump, Submersible
3/4 Hp
1 Hp
Sander, Belt
Saw, Chain
12”
14”
Saw, Circular
6-1/2”
8-1/4”
2000
3500
6500
400
600
900
2500
3300
3300
1200
1400
2400
3500
5000
9000
3000
3500
1600
1800
2200
1200
3000
3200
2150
NOTE: This chart is to be used only as a guide. Motor starting requirements have many variables.
Electrical Formulas – Alternating Current
Single Phase
Watts = Volts x Amps x Power Factor
Amps =
kW x 1000
V x pf
Notes: 1 kilowatt (kW) = 1000 Watts
Typical Power Factor for Single Phase is 1.0 (Unity)
Three Phase
Watts = Volts x Amps x Power Factor x 1.732
kW x 1000
Amps = 1.732 x V x pf
Notes: 1 Kilowatt (kW) = 1000 Watts
Typical Power Factor for Three Phase is 0.8
Information provided is subject to change without notice. Contact your local Baldor District Office for additional information.
Download PDF

advertising