DS7445i/V2-EXP, DS7447E/V2-EXP | Installation Instructions | 1.0 General Information
1.0 General Information
The DS7447E and DS7447V2 are four-wire
alphanumeric LCD keypads. The DS7445i and
DS7445V2 are four-wire LED keypads. All four
keypads support all system functions and are
compatible with the DS7060, DS7080i Series,
DS7200/DS7200V2 Series, and DS7400Xi Series
Control Panels. The DS7447E/DS7447V2 is required
for local programming.
Figure 1: Front View of Keypads
EN | 2
The keypads can be surface mounted, or mounted to
gang boxes (standard single or double) or 50.8 mm
(4 in.) square boxes. Refer to Table 1 for general
wiring guidelines.
Table 1:
Keypad Wiring Guidelines
Wire Gauge
Wire Type
Maximum Distance
Allowed (between control
panel and each keypad)
0.88 mm (#22 AWG)
minimum
No shield, 4-wire
305 m (1000 ft)
This product complies with all the
applicable CE directives.
2.0 Keypad Addresses
Each keypad must have a unique address configured
using its address pins and must be programmed using
the control panel.
See Figure 2 and Figure 3 for address jumper and
mode pin locations.
1. Select a different address (0 to 32) for each
keypad. Refer to Table 2 and Table 3 (in both
tables, "ON" indicates a shorting jumper across
both pins).
2. Place the shorting jumpers over the address pins
Figure 4 shows proper shorting jumper
placements.
Figure 2: Internal View of DS7445i and
DS7445V2 Keypads
1
2
3
MODE
ADDRESS
1
1 – DS7445i LED Keypad
2 – DS7447E LCD Keypad
3 – DS7445V2 LED Keypad
4 – DS7447V2 LCD Keypad
Bosch Security Systems | 4/04 | 4998122645D
2
4
8
16
4
1 – Address jumper pins
2 – Mode pins
3 – Option bus terminals
4 – Sounder
DS7445i/V2-EXP, DS7447E/V2-EXP | Installation Instructions | 2.0 Keypad Addresses
Figure 3: Internal View of DS7447E and
DS7447V2 Keypads
1
Table 3:
2
EN | 3
Keypad Address Selections for
DS7200/DS7200V2 Series Control
Panels
MODE
1
ADDRESS
2 4 8 16
Module
Address
5
1 – Address jumper pins
2 – Mode pins
3 – Sounder
4
3
4 – Option bus terminals
5 – Contrast control
Figure 4: Shorting Jumper Placements
1
2
1 – Jumper Plug ON (covers both pins)
2 – Jumper Plug OFF (3 possible configurations)
Table 2:
Module
Address
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Keypad Address Selections for
DS7060, DS7080i Series, and
DS7400Xi Series Control Panels
1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
Address Jumpers
4
8
18
OFF OFF OFF
OFF OFF OFF
OFF OFF OFF
OFF OFF OFF
ON
OFF OFF
ON
OFF OFF
ON
OFF OFF
ON
OFF OFF
OFF ON
OFF
OFF ON
OFF
OFF ON
OFF
OFF ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
Bosch Security Systems | 4/04 | 4998122645D
Mode
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
0*
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
Address Jumpers
4
8
18
OFF OFF OFF
OFF OFF OFF
OFF OFF OFF
OFF OFF OFF
ON
OFF OFF
ON
OFF OFF
ON
OFF OFF
ON
OFF OFF
OFF ON
OFF
OFF ON
OFF
OFF ON
OFF
OFF ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
OFF OFF ON
OFF OFF ON
OFF OFF ON
OFF OFF ON
ON
OFF ON
ON
OFF ON
ON
OFF ON
ON
OFF ON
OFF ON
ON
OFF ON
ON
OFF ON
ON
OFF ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF OFF OFF
*Installer’s Mode Address Setting: Use for direct
connection of Installer’s Keypad.
Mode
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
DS7445i/V2-EXP, DS7447E/V2-EXP | Installation Instructions | 3.0 Mounting
3.0 Mounting
4.0 Wiring
3.1
4.1
•
Considerations
Ideally, one keypad should be located close to
the primary entry/exit door of the premises, and
the wire length must be within 305 m (1000 ft) of
the control panel.
•
Do not mount outdoors [see Section 7.0
Commercial Fire Applications (DS7400Xi Series) for
commercial fire restrictions].
•
The keypad should be mounted no higher than
shoulder height of the shortest person using the
system.
3.2
1.
2.
3.
4.
Instructions
Insert a small flat-head screwdriver in each slot at
the bottom of the base. Press up, and pull the
cover off.
Using the base as a template, mark the location of
the mounting holes (use any holes). Refer to
Figure 5 to select the mounting holes.
Provide an opening in the mounting surface for
the wiring.
Start the mounting screws.
EN | 4
Control Panel to Keypad Wiring
Be sure all wiring is unpowered before
routing.
1.
2.
3.
4.
Route wiring from the control panel to the
keypads. Up to two keypads can be used on any
single 305 m (1000 ft) run of 0.8 mm (#22 AWG)
wire. Up to three keypads can be used on any
single 305 m (1000 ft) run of 1.2 mm (#18 AWG)
wire.
Bring the wiring through the wire entrance in the
keypad’s base and secure the base (Figure 5).
Connect the wiring to the keypad’s terminal strip
(Figure 6).
Place the keypad cover onto the base. While
feeding the excess wiring through the back of the
base, press the cover straight in until it latches.
Figure 6: Keypad Terminal Connections
1
2
Do not secure the base at this time.
3
4
Figure 5: Back View of Keypad
1 – Power + (red)
2 – Power – (black)
3 – Data in (green)
4 – Data out (yellow)
1
1
2
3
4
5
6
1 – Double gang mounting slots
2 – Single gang mounting slots
3 – Wire entrance
4 – Terminal strip opening. Do not use as wire
entrance!
5 – Tamper Switch. Install spring on tamper
switch!
6 – Sounder opening
Bosch Security Systems | 4/04 | 4998122645D
DS7445i/V2-EXP, DS7447E/V2-EXP | Installation Instructions | 5.0 DS7447E/V2 Contrast Control
5.0 DS7447E/DS7447V2
Contrast Control
The DS7447E/DS7447V2 Keypad contrast (refer to
Figure 3 for the location of the contrast control) can be
increased by turning the contrast control clockwise.
To decrease the contrast, turn the control
counterclockwise.
6.0 Special Key Labeling
Do not label if keys are unprogrammed.
Consult your control panel’s programming
instructions for specific function key assignments.
Figure 8 shows typical function button assignments
(the DS7445V2/DS7447V2 is shown; the same button
assignment applies to the DS7445i/DS7447E).
Figure 7: Special Key Labeling
1
2
1 – Fire
2 – Special emergency
3 – Panic
Bosch Security Systems | 4/04 | 4998122645D
EN | 5
3
DS7445i/V2-EXP, DS7447E/V2-EXP | Installation Instructions | 7.0 Instruction Label and Slide
7.0 Instruction Label and Slide
Two instruction labels are provided and one must be
placed onto the pull-out slide. The slide can be
installed to pull from the left or from the right (slides
into rear of base; refer to Figure 8).
Use DS7447 Info Card (P/N: 28815) when installing
keypad(s) for use with the DS7060, DS7080i Series,
and DS7400Xi Series Control Panels.
8.0 Troubleshooting
Table 4:
Keypad Troubleshooting
Keypad Notification
DS7445i/DS7445V2
continuous sounder.
Use DS7445i/V2, DS7447E/V2 Info Card (P/N: 49646)
when installing keypad(s) for use with the DS7200/V2
Series Control Panels.
Be careful when installing the label. Place
it as near to the pull-tab as possible.
DS7447E/DS7447V2
continuous sounder and
“System Fault”
displays.
Figure 8: Instruction label and Slide Installation
1
1
2
3
4
1 – Label (two supplied)
2 – Slide label in from either side
3 – Align label behind both sets of teeth
4 – Label installed (wiring on other side)
Bosch Security Systems | 4/04 | 4998122645D
EN | 6
DS7447E/DS7447V2
continuous sounder and
“Not Programmed”
displays.
DS7445i/DS7445V2 3beep error tone on all
keypads.
DS7447E/DS7447V2
3-beep error tone on all
keypads and “Entry
Error. Please try
again” displays.
Possible Causes
•
Yellow and green wires are
disconnected.
•
Keypad not programmed
properly at the control
panel.
•
Control panel
malfunctioned. Replace the
control panel.
•
Yellow and green wires are
disconnected.
•
Control panel
malfunctioned. Replace the
control panel.
•
Keypad not programmed
properly at the control
panel.
•
Two or more keypads have
same address.
DS7400 Series only:
•
DS7430 MUX Module not
installed on main board
correctly. Check pin
alignment.
•
Keypad and another device
on the option bus have the
same address.
DS7445i/V2-EXP, DS7447E/V2-EXP | Installation Instructions | 8.0 Troubleshooting
Bosch Security Systems | 4/04 | 4998122645D
EN | 7
Bosch Security Systems
130 Perinton Parkway
Fairport, NY 14450-9199
Customer Service: (800) 289-0096
Technical Support: (888) 886-6189
© 2004 Bosch Security Systems