Download PDF
Avigilon™ Control Center 5
System Integration Guide
for Jacques™ IP Audio Intercom System
© 2010 -2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license is granted
with respect to any copyright, industrial design, trademark, patent or other intellectual property rights of Avigilon
Corporation or its licensors.
AVIGILON is a registered and/or unregistered trademark of Avigilon Corporation in Canada and other
jurisdictions worldwide. JACQUES is a trademark of Jacques Technologies Pty Ltd in Australia. Other product
names mentioned herein may be the unregistered and/ or registered trademarks of their respective owners. ™
and ® are not used in association with each trademark in this document.
This manual has been compiled and published covering the latest product descriptions and specifications. The
contents of this manual and the specifications of this product are subject to change without notice. Avigilon
reserves the right to make changes without notice in the specifications and materials contained herein and shall
not be responsible for any damages (including consequential) caused by reliance on the materials presented,
including but not limited to typographical and other errors relating to the publication.
Avigilon Corporation
http://www.avigilon.com
Revised: 2014-12-10
INT-JCQ-D
ii
Table of Contents
Introduction
1
Requirements
1
For More Information
1
Installation
2
Upgrading the Integration
2
Server
2
Client
2
Checking the Avigilon™ License
2
Configuration
3
Configuring Tags in Jacques™ HLI
3
Adding an Integration User in Avigilon™ Control Center
3
Adding Avigilon™ Alarms
3
Enabling Audio in the Avigilon™ Control Center Client
4
Configuring the Avigilon™ Gateway for Jacques™
5
Configuring the Server Settings
5
Mapping Alarms and Audio
7
Troubleshooting
9
Mapped Avigilon™ Control Center Alarms Displayed as Unknown
9
Acknowledge Alarm on Call Termination Behavior does not Match What is Configured
9
iii
Introduction
The Avigilon™ Control Center software integration with the Jacques™ IP Audio Intercom System allows alarms in
the Avigilon Control Center to be triggered whenever an intercom event is activated in the Jacques System, and
to record audio communication from the Jacques™ system with video from a camera connected to the Avigilon
system.
The Jacques system uses tags to communicate events between intercom units. Tags are a series of numbers
that users dial to call other intercom units and initiate specific actions. The integration enables tags to be linked
to specific Avigilon alarm actions and be recorded with the associated video. A possible use case for the
integration is for users to view video from a camera pointed at an intercom station. When a tag dials another
Jacques intercom station, the corresponding alarm is triggered in the Avigilon Control Center Client and the
alarm video is displayed. The audio from the intercom station is recorded with the alarm video.
Requirements
Vendor
Requirements
Avigilon Control Center Server software 5.x or later
Avigilon Third Party Integration license:
Avigilon
ACC5-JAQS-INTCM
Avigilon integration executable file:
Avigilon
AvigilonJacquesGateway.exe
Jacques Jacques 650 Series IP Communications System
Jacques High Level Interface (HLI)
For mapping audio from the Jacques system to cameras connected to the Control Center software:
Jacques Jacques system controller (TCH-2MXH or above) featuring DAR and SIP Recording Software Module
(v6.35 or above) and associated JEM2 hardware (IPM350 master station & VSL-35x (JEM2 slave
intercom terminals)
For More Information
For More Information about the procedures outlined in this guide, refer to the following specific software
documentation:
l
Avigilon™ Control Center Client User Guide
l
Avigilon™ Control Center Server User Guide
l
Tag Configuration for Jacques 650 Series IP Communications System
1
Introduction
Installation
Upgrading the Integration
If you are upgrading to this version of the Avigilon™ integration software, be aware that this version of the
integration is only compatible with Avigilon™ Control Center 5.4 or later.
Avigilon Control Center 5 provides the ability to organize multiple servers into Sites and share settings between
servers. To use this feature effectively, you must upgrade all servers in your Site before upgrading the
integration.
This version of the integration can run both the Windows service and the Configuration Tool at the same time, so
two HLI tags are required. One HLI tag must be configured for the Windows service and one for the
Configuration Tool. For more information about HLI tags, see Configuring Tags in Jacques™ HLI on page 3.
To upgrade from the Control Center 4 version of the integration or the previous version of Control Center 5,
simply run the installer and follow the prompts. After the upgrade is complete, open the Configuration Tool and
add the HLI tags for the integration. Click Update Service to start the upgraded integration.
Server
Install the following on any server in your network. The applications do not need to be installed on the same
server.
1. The Avigilon™ Control Center Server software.
2. The Jacques™ High Level Interface for third party integration.
3. The Avigilon™ Gateway software integration with Jacques VoIP Voice Communications Systems.
Client
Install the following as needed:
l
Install the Avigilon™ Control Center Client software on the computers that require access to the Avigilon
Control Center System
Checking the Avigilon™ License
After you have installed all the required software, check that the Avigilon license was applied correctly.
1. Open the Avigilon Control Center Admin Tool.
2. Select the Settings tab and click Licensing. The License Activation dialog box appears.
The dialog box must say Integration Connections: Yes or the software was not properly licensed.
Installation
2
Configuration
Configuring Tags in Jacques™ HLI
The Jacques IP Communication System has a set of pre-configured tags that connect you to other intercoms in
the system or initiates an action. If you require a customized tag for the Avigilon integration with Jacques, see
Tag Configuration for Jacques 650 Series IP Communication System for more information.
NOTE: If you are upgrading from a previous version of the integration, you will need to add a second HLI tag for
the integration so the Windows service and the Configuration Tool can run simultaneously.
Adding an Integration User in Avigilon™ Control Center
To protect the security of the Avigilon™ Control Center system, add a user specifically for connecting the
integration to the Control Center software. See the Avigilon™ Control Center Client User Guide for details about
how to add users.
This user must have View live images and Broadcast to speakers permission to enable all integration features.
This user will be used to connect the Avigilon Control Center system to the integration.
Adding Avigilon™ Alarms
Create the Avigilon alarm actions you want to be integrated with the Jacques system, and include the required
cameras and settings for the alarm.
Alarms are manually created in the Avigilon Control Center Client software, and can only be created by users
with Alarm Setup permissions. An administrator with the required permissions can create the alarms before the
integration is used.
1. In the Avigilon™ Control Center Client software, open the Site Setup tab and click
2. In the Alarms dialog box, click
.
.
3. On the Select Alarm Trigger Source page, select External Software Event from the Alarm Trigger Source:
drop down list. Click after you complete each page.
4. On the Select Linked Cameras page, select the cameras to link to this alarm, and set the Pre-Alarm
Record Time: and Recording Duration:.
5. On the Select Alarm Recipients page, select the Control Center user that was added for the integration.
You can also add any other groups or users that need to be notified when this alarm is triggered.
6. (Optional) If you would like to trigger an action when an alarm is acknowledged, select Activate selected
digital output(s) on alarm acknowledgement check box.
a. Select the digital outputs to be activated and specify the duration.
b. Select Require user confirmation before activating digital output(s) check box if the user needs to
Configuration
3
confirm the alarm before the digital output action is initiated.
7. Enter a name for the alarm and set the alarm priority. The alarm name is used to identify the alarm during
the integration.
8. Ensure Enable alarm check box is selected then click
.
Enabling Audio in the Avigilon™ Control Center Client
If you would like to link audio from the Jacques™ system with recorded video in the Avigilon system, you must
first enable audio in the Control Center Client software.
NOTE: Audio output must be supported on the camera that is linked to the Jacques tag.
1. In the Avigilon™ Control Center Client software, open the Camera Setup tab and click
.
2. In the following dialog box, select the Enable check box.
3. Select the Record speaker output check box, or audio will not be recorded with the video.
4. Click OK.
You do not need to connect a physical speaker to the camera. In the Gateway Configuration Tool, you will link
the camera to the appropriate Jacques audio tag.
4
Enabling Audio in the Avigilon™ Control Center Client
Configuring the Avigilon™ Gateway for Jacques™
The Avigilon Gateway application allows Jacques™ events to trigger alarms within the Avigilon system so that
your video and VoIP communication events can be monitored from the same system.
The Avigilon Gateway application is composed of two parts: the Windows service that runs automatically in the
background, and the Configuration Tool software that is used to map alarms between the two systems.
Configuring the Server Settings
Configure the Avigilon™ Gateway for Jacques™ to access the two applications.
The Configuration Tool remembers the server configurations, so you do not need to repeat this procedure if the
settings remain the same.
1. Open the Configuration Tool software. Start > All Programs > Avigilon > Configure Avigilon Jacques
Gateway.
2. In the Configuration Tool, click Configure Connections.
3. Click Add to add the Avigilon Server.
4. In the following dialog box, enter the Avigilon server IP Address, User Name and Password, then click OK.
Configuring the Avigilon™ Gateway for Jacques™
5
Use the username and password created in the Avigilon configuration. See Adding an Integration User in
Avigilon™ Control Center on page 3.
If your server is part of a Site, the alarms from the entire Site will be added to the integration.
5. Click OK.
6. Enter the Jacques server IP address and the two HLI tag serial numbers for the integration. For more
information, see Configuring Tags in Jacques™ HLI on page 3.
7. If you want to link a Jacques™ audio source with a camera in the Avigilon system, select the Enable Audio
check box then complete the following fields:
a. DAR IP – enter the IP address for the Jacques Digital Audio Recorder (DAR). This is the JccpServer
Host setting listed on the DAR page of the Jacques System Configuration.
b. TAP Sender IP – enter the tap-public-transmit-bind-address listed in the dar.sip.ini file. This
file is available in the Jacques System Configuration.
c. Recorder Interface – select the network interface that is connected to the Jacques DAR output.
8. Click Done to close the Configure Connections window.
6
Configuring the Server Settings
Mapping Alarms and Audio
1. In the Configuration Tool, select the Alarms tab to map alarms together.
a. Select an Avigilon alarm and a Jacques™ tag.
o
Select the Acknowledge Avigilon alarms on call termination check box if the Avigilon
alarms do not need to be manually acknowledged within theAvigilon Control Center Client
each time.
NOTE: The Jacques tag refers to the intercom that is making the call, not the intercom that
is receiving the call.
o
Click Remove Selected Tags from Mapping to hide tags that have already been mapped.
b. Click >> to map the alarm together. The mapped alarm is added to the Alarm Mappings list.
If you need to remove a mapped alarm, select mapped alarm and click <<.
c. Repeat the previous steps until all the alarms you need are mapped.
d. Click Save and Apply.
2. Select the Audio tab to map Jacques audio devices with cameras connected to the Avigilon system.
NOTE: If you did not enable audio in the Configure Connections dialog box, the Audio tab is not
displayed. Skip the remaining steps if you do not intend to record audio with video in the Avigilon
system.
Mapping Alarms and Audio
7
a. Select an Avigilon™ camera and a Jacques™ tag. Only cameras that have audio enabled are listed.
For more information, see Enabling Audio in the Avigilon™ Control Center Client on page 4.
Tip: To ensure that all calls are recorded, create a mapping for each audio source tag.
b. Click >> to map add the audio mapping. The mapped devices is added to the Audio Mappings list.
If you need to remove a mapping, select an audio mapping and click <<.
c. Repeat the previous steps until all the required cameras are mapped with audio sources.
d. Click Save and Apply. The integration gateway is updated with all the new or changed mappings.
8
Mapping Alarms and Audio
Troubleshooting
If the following troubleshooting solutions do not resolve your issue, contact Avigilon Technical Support –
http://avigilon.com/support-and-downloads/
Mapped Avigilon™ Control Center Alarms Displayed as Unknown
Mapped alarms in the Configuration Tool are labeled in red as “Unknown.” The Avigilon™ Control Center Server
that the integration is connected to displays an “Error” status in the Configure Connections dialog box.
This issue occurs if the Control Center Server has rebooted or is offline.
Perform the following steps to ensure the integration functions correctly:
1. Check that the Avigilon Control Center Server is online and connected to the local network.
2. When the Avigilon Control Center Server is back online, open the Configuration Tool and click Configure
Connections.
3. If the Avigilon Control Center Server is online, the server status would be “Ready.” If it is not, check the
server connectivity again.
4. Close the Configure Connections dialog box. The Configuration Tool should now display the correct
alarm names.
5. Click Save and Apply to ensure the alarm mappings are active.
Acknowledge Alarm on Call Termination Behavior does not Match
What is Configured
When the Acknowledge Avigilon alarm on call termination option is enabled/disabled in the Configuration Tool,
the opposite occurs.
This issue may occur if the Gateway service was not successfully restarted after the setting was changed.
1. On the system with the Avigilon Gateway for Jacques integration installed, open the services dialog.
2. Restart the Avigilon to Jacques Gateway service.
For more information on accessing the services dialog and restarting a service, refer to
http://technet.microsoft.com/en-ca/library/cc736564(v=ws.10).aspx#BKMK_services.