Bryant | 561C | 561C (60 Hz) - Free Manual Downloads

561C (60 Hz)
ELECTRIC
AIR CONDITIONER
Sizes 018 thru 060
Model 561C Energy-Efficient Air Conditioners incorporate innovative technology to provide reliable summer cooling performance. Built into these units are the features most desired by
homeowners today including SEER ratings of up to 11.5 when
used with components designated by manufacturer. All models
are listed with UL, c-UL, ARI, CEC, and CSA-EEV.
AVAILABLE OPTIONS
UNIT DESIGN—Copper tube, enhanced sine wave aluminum
fin coil is designed for optimum heat transfer. Vertical air discharge carries sound and hot condenser air up and away from
adjacent patio areas and foliage. Heat pump-style base pan for
easy removal of water, dirt, and leaves.
ELECTRICAL RANGE—All units are offered in 208–230v single phase. Three-phase units are available from 030 through
060 sizes in 208/230v and from 036 through 060 sizes in 460v.
WIDE RANGE OF SIZES—The 561C is available in 7 nominal
sizes from 018 through 060 to meet the needs of residential and
light commercial applications.
WEATHER-PROTECTIVE CABINET—The steel panels are
protected with a galvanized coating then covered with a layer of
zinc phosphate. A modified polyester powder coating is then
applied and baked on, providing each unit with a hard, smooth
finish that will last for many years.
All screws on cabinet exterior are coated for a long-lasting, rustresistant, quality appearance.
TOTALLY ENCLOSED FAN MOTOR—Means greater reliability
under rain conditions and dependable performance for many
years. The permanent-split-capacitor-type motor was designed
for optimum efficiency. Then, under extreme conditions, the
motor was tested and qualified to help ensure the greatest reliability.
APPLICATION VERSATILITY—The unit can be combined with
a wide variety of evaporator coils and blower packages to provide quiet, dependable comfort. Unit can be installed on a roof
or at ground level on a slab.
EXTERNAL SERVICE VALVES—The service valves are brass,
front seating type. The 561C has sweat field connections.
Valves are externally located so refrigerant tube connections
can be made quickly and easily. Each valve has a service port
for ease of checking operating refrigerant pressures.
EASY SERVICEABILITY—One access panel provides access
to electrical controls and compressor. Removal of wire dome
gives access to fan motor and removal of the top gives access
to the coil.
COMPRESSOR PROTECTION—Each compressor is protected with internal temperature- and current-sensitive overloads. An internal pressure relief valve provides high-pressure
protection to the refrigerant system.
LIMITED WARRANTY—Standard 1-year warranty on parts,
with an additional 4-year warranty on compressor.
Form No. PDS 561C.18.6
UNIT
SIZE
018
024
030
036
036
042
042
048
060
060
SERIES
A, D
A, D
A, D
A, B, D
E
A, C
B
A, B, C
A, E
B
A
18
18
22-1/2
22-1/2
22-1/2
22-1/2
22-1/2
30
30
30
B
21-15/16
23-15/16
21-15/16
25-15/16
25-15/16
29-15/16
29-15/16
27-15/16
35-15/16
29-15/16
AIR DISCHARGE
TIEDOWN
KNOCKOUTS
(2) PLACES
3/8-IN. DIA
AIR IN
N
C
3-3/16
3-3/16
3-3/16
3-3/16
3-3/16
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
E
M
D
5/8
5/8
3/4
3/4
3/4
7/8
7/8
7/8
7/8
7/8
F
G
H
AIR IN
—2—
AIR IN
B
P
A SQ
D DIA VAPOR LINE CONN
AIR DISCHARGE
1 1/4″
2 7/8″
G
16-5/16
16-5/16
19-3/4
19-3/4
19-3/4
19-13/16
19-13/16
27-1/4
27-1/4
27-1/4
H
17-3/4
17-3/4
22-1/4
22-1/4
22-1/4
22-1/4
22-1/4
29-3/4
29-3/4
29-3/4
UNIT DIMENSIONS
J
10-3/16
10-3/16
14-3/8
14-3/8
14-3/8
14-3/8
14-3/8
20
20
20
K
16-1/8
16-1/8
19-9/16
19-9/16
19-9/16
19-9/16
19-9/16
27-1/16
27-1/16
27-1/16
L
17-3/4
17-3/4
22-1/16
22-1/16
22-1/16
22-1/16
22-1/16
29-9/16
29-9/16
29-9/16
M
7-7/8
7-7/8
10-3/8
10-1/4
10-3/8
10-1/4
10-3/8
15
15-1/2
15-1/2
C
N
8-3/8
8-3/8
10-1/4
9-1/2
10-3/4
9-1/2
10-3/4
13
14
14
A97017
3/8-IN. DIA LIQUID
LINE CONN
FIELD CONTROL SUPPLY
CONN 7/8-IN. DIA HOLE
FIELD POWER SUPPLY CONN
7/8-IN. DIA HOLE WITH
1 1/8-IN. DIA KNOCKOUT
AND 1 3/8-IN. DIA KNOCKOUT
NOTES:
1. Allow 30 in. clearance to service side of
unit, 48 in. above unit, 6 in. on one side, 12 in.
on remaining side, and 24 in. between units for proper airflow.
2. Minimum outdoor operating ambient in cooling mode is
55°F, max. 125°F.
3. Series designation is the 14th position of the unit
model number.
4. Center of gravity .
L
DIMENSIONS (IN.)
K
F
15
15
18-1/8
18-1/8
18-1/8
18-1/8
18-1/8
23-1/2
23-1/2
23-1/2
J
AIR DISCHARGE
E
3
3
3-11/16
3-11/16
3-11/16
3-11/16
3-11/16
6-1/2
6-1/2
6-1/2
AIR IN
P
9-3/8
9-1/2
10-3/4
11-1/4
11-1/4
11-5/8
11-1/8
14-1/2
15-1/2
15
MINIMUM
MOUNTING
PAD DIMENSIONS
18 X 18
18 X 18
22-1/2 X 22-1/2
22-1/2 X 22-1/2
22-1/2 X 22-1/2
22-1/2 X 22-1/2
22-1/2 X 22-1/2
30 X 30
30 X 30
30 X 30
DIMENSIONS—561C
CHECK-FLO-RATER® PISTON CHART
PISTON*
IDENTIFICATION NO.
52
57
67
73
70
76
82
88
84
93
90
UNIT SIZE
018-A, D
024-A, D
030-A, D
036-A, D, E
036-B
042-A, C
042-B
048-A, C
048-B
060-A, E
060-B
* Piston listed is for any approved coil non-capillary tube combination.
Piston is shipped with outdoor unit and must be installed in an approved
indoor coil.
RECOMMENDED TUBE DIAMETERS
UNIT
SIZE
018, 024
030, 036
042, 048
060
Liquid Tube Diameter (In.)
0 to 50 Ft
Tube Length
Long-Line Applications*
3/8
3/8
0 to 50 Ft
Tube Length
5/8
3/4
7/8
1-1/8
Vapor Tube Diameter (In.)
Long-Line Applications*
(Maximum Diameter)
3/4
7/8
1-1/8
1-1/8
* For tube sets between 50 and 175 ft, consult Residential Split System Long-Line Application Guideline.
SOUND POWER (dBA)
125
55.5
57.5
59.5
55.5
55.0
54.0
57.0
55.0
56.0
56.5
58.0
59.0
57.0
58.5
57.0
61.0
57.5
57.5
58.0
OCTAVE BAND CENTER FREQUENCY (Hz)
500
1000
2000
68.5
73.0
71.0
69.5
72.0
71.5
69.5
74.0
73.0
68.0
71.0
70.5
73.5
74.0
71.0
72.5
73.0
70.5
73.0
74.0
72.0
73.0
74.5
72.0
69.0
75.5
75.0
73.5
75.5
74.5
73.0
71.5
69.5
68.5
75.5
71.5
72.5
71.5
69.5
74.0
77.0
72.5
72.0
73.0
68.5
70.0
74.0
75.5
69.0
72.5
70.5
75.0
76.0
70.5
70.0
74.0
72.0
250
64.0
64.0
65.0
63.0
62.5
68.5
64.5
64.0
64.5
70.0
69.5
66.5
69.0
72.5
67.5
69.0
68.0
69.5
64.0
T
IFIED O ARI A
RT
S
C
CE
NING
ITIO
ND
A
AIR
CO
Y
EQ
RI
YING WITH
PL
OM
UNIT
AR
SOUND
LEVEL (dBA)
80
80
80
82
80
80
82
82
82
82
82
82
82
82
82
82
82
82
82
MANUFACTUR
ER
UNIT
SIZE
018-A
018-D
024-A
024-D
030-A
030-D
036-A
036-B
036-D
036-E
042-A
042-B
042-C
048-A
048-B
048-C
060-A
060-B
060-E
UIP M E N T
STA
NDARD
21
0
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE SYSTEM
IS LISTED WITH ARI.
—3—
REGISTERED QUALITY SYSTEM
4000
66.5
68.0
70.0
67.5
67.5
67.0
73.0
68.5
72.0
71.0
68.0
73.0
68.0
70.0
67.0
74.5
71.0
69.0
71.0
8000
59.5
60.0
62.0
58.5
59.5
61.5
65.5
64.0
69.5
65.0
63.5
65.5
64.0
65.0
60.5
66.5
70.0
63.0
67.0
Preview Limit Reached! To view more of this manual,
please visit:
http://freemanualdownload.com/Bryant-561C-free-manu
al-download
Download PDF