Vicon | SVFT-C22CA-C | SVFT Pressurized Specification

Product Specification
The SurveyorVFT Pressurized Camera Dome housing has all the
features and functions of the SurveyorVFT Camera Dome
System. The interior is pressurized with dry nitrogen gas and
regulated with a relief valve. In addition, the interior is
environmentally controlled using a thermostatically-controlled
heater/fan assembly. This environment is characterized as ideal
(IP67 rated) and provides the maximum protection against the
elements that would normally cause rapid deterioration of
electronic and video components. The exterior is UV resistant
polyethylene plastic. The lower dome is fabricated from
distortion-free clear acrylic plastic. Refer to Table 1 for models.
There is a wall mount and pipe adapter available for mounting the
pressurized housing.
Vicon strongly recommends the use of uninterruptible
power supply systems (UPS) to prevent voltage
fluctuations that can affect operation, cause video loss
and damage to the equipment.
Pressurized
Camera Dome Housing
•
•
•
•
•
•
•
•
Sealed and pressurized housing offers
maximum environmental protection
Provides environmental control for
SurveyorVFT Camera Dome
Pendant or wall mount available
Versions available with color 22X or
day/night 23X
Prefabricated multi-conductor cable
assembly available
Compatible with all Vicon matrix systems
Low pressure sensor alarm output
Daisy chain connectivity with full duplex
capability
ASSOCIATED EQUIPMENT AND ACCESSORIES
Model SVFT-PR-WM Wall Mount, Product Code 8381: Used
to easily mount the pressurized housing to a horizontal surface
for an indoor or outdoor application. A convenient access door
allows installation and servicing. Refer to Product Specification
144.
Model SVFT-PR-P Pipe Adapter, Product Code 8382: Used to
easily mount the pressurized housing to various SurveyorVFT
mounts or a vertically oriented 1-1⁄2 inch NPT schedule 40 pipe.
Refer to Product Specification 144.
Model S2-PR-CBL-12A Pre-Wired Cable, Product Code 8073:
Prefabricated cable for all connections.
Model
Number
Product
Code
Camera Type/
Format
Optical Zoom/
Total Zoom
SVFT-PR22
8710
Color/ NTSC
with ExView Technology
22x/264x
SVFT-PR22C
8710-01
Color/PAL with ExView Technology
22x/264x
SVFT-PR23
8711
Color/NTSC
(day/night)
23x/276x
SVFT-PR23C
8711-01
Color/PAL (day/night)
23x/276x
For the ViconNet (V) option, add –20 to the product code; for Fiber Optic option, add –30 to the product code; for UTP (T) option,
add –40 to the product code.
Table 1: SurveyorVFT Pressurized Model Versions
Model No:
SurveyorVFT
Pressurized
Vicon part number 8009-7004-10-00
Product Code:
See Table 1
SEC: 3
SPEC:
V004-10
REV: 204
Product specifications subject to change without notice.
1
Product Specification
Model Number
Product Code
Description
V212-NVT
V213-NVT
7631
6518
V652R-NVT
7453
Receiver, converts UTP video to composite up to 500 ft from transmitter
Receiver, converts UTP video to composite up to 1000 ft from transmitter
Receiver, converts UTP video to composite up to 3000 ft from transmitter (does not support
Vicoax systems)
16-Channel Hub Receiver, converts UTP video to composite up to 1000 ft from each transmitter
16-Channel Hub Receiver, converts UTP video to composite up to 3000 ft from each transmitter
(does not support Vicoax systems)
V1613-NVT
7648
V1662-NVT
6519
Table 1 (cont’d): UTP Receiver Options
Model Number
Product Code
VF-1400R
VF-1400RR
VF-SR-20/2
8421-00
8421-02
8423-00
Description
Receiver, for SurveyorVFT transmission, simplex video and duplexRS-422 data
Receiver, for SurveyorVFT transmission, simplex video and duplexRS-422 data
Card cage with power supply
Table 1 (cont’d): Fiber Optic Receiver Options
Model Number
S28WPS
S28PS-HD
Product Code
7030
7862
Description
28 VAC output, 4 amps, for outdoor SurveyorVFT Camera Domes
Heavy-duty single-channel for SurveyorVFT pressurized and outdoor impact-resistant camera domes
Table 1 (cont’d): Power Supplies
2
Model No:
SurveyorVFT
Pressurized
Product Code: See
Table 1
SEC: 3
SPEC:
V004-10
REV: 204
Contractors’ Specification
TECHNICAL SPECIFICATIONS
DIVISION 13 - SPECIAL CONSTRUCTION
SECTION 137_ _ - SECURITY CCTV SYSTEM
SECURITY SYSTEM
PART 2 - PRODUCTS
2.01
GENERAL
A.
All equipment and materials used shall be standard components, regularly manufactured, regularly utilized
in the manufacturer’s system.
B.
All systems and components shall have been thoroughly tested and proven in actual use.
C.
All systems and components shall be provided with the availability of a toll free 24-hour technical support
phone number from the manufacturer. The phone number shall allow for immediate technical assistance
for either the dealer/installer or the end user at no charge.
D.
All systems and components shall be provided with an explicit manufacturer warranty.
2.02 CAMERA DOME PRESSURIZED HOUSING
A.
B.
C.
D.
E.
F.
G.
The pressurized dome shall be an alternate mounting configuration for a camera dome. It shall be a
completely self-enclosed, sealed housing in a pressurized dry nitrogen gas environment. It shall be IP67
rated and provide an ideal climate for the camera dome with respect to temperature, humidity and water
and dust ingress.
The housing shall have two (2) mounting configurations, wall mount and 1-1⁄2 inch NPT schedule 40 pipe
thread mount. The trim ring/lower dome assembly shall be attached to the housing with a safety cord.
The pressurized housing shall use a mechanical method to ensure its seal. The seal method shall be a
bolt compressed neoprene O-ring.
The enclosure shall be backfilled with dry nitrogen gas to 5 psi nominal. A relief valve shall provide gas
release at 7 psi and a normally open (NO) low-pressure switch shall close when the pressure falls to 1 psi
nominal. The scheme shall meet a leak rate not to exceed 2.0 psi per year. This scheme shall also meet
standard IP67 for full protection of components due to water and dust ingress.
The pressurized dome shall utilize a 23-pin pressure-rated connector to bring all signals from the interior
to the exterior including power, video, communication, alarms and relays. It shall provide full performance
of the camera dome. The pressurized dome shall provide electrical surge protection. Surge protection
shall be provided on the video and power connector.
The camera dome shall have the following mechanical specifications:
1. Dimensions: Housing Diameter: 13.0-in. (333 mm); Dome Diameter: 9.8 in. (249 mm).
Total Height: 14.0-in. (355 mm); Housing Height: 8.25 in. (210 mm).
2. Weight:
12.0 lb (5.4 kg); 16.5 lb (7.5 kg) with camera drive.
3. Construction: Housing: Lightweight aluminum with a UV resistant polyethylene plastic
exterior sunshield.
Dome: Distortion-free clear acrylic plastic.
4. Color:
White sunshield, black housing and trim ring, clear dome
Ambient temperature and humidity shall be: -30 to 165° F (-34 to 74° C) in accordance with NEMA 2.1.5.1
STD2, -40 to 132° F (-40 to 55° C) continuous rotation; up to 100% relative, condensing. Maintained
temperature and humidity range shall be: 14 to 140° F (-10 to 60° C); up to 90% relative, noncondensing.
Model No:
SurveyorVFT
Pressurized
Product Code: See
Table 1
SEC: 3
SPEC:
V004-10
REV: 204
3
Contractors’ Specification
2.0.3
4
COMPACT CAMERA DOME SYSTEM
A.
The motorized dome shall have internal CPU-circuitry and provision for external programming via
standard RS-422/485 protocol or enhanced VicoaxII protocol. Options for TCP/IP, fiber optic and twisted
pair (UTP) video transmission shall be available. This circuitry shall provide for an external power supply
input, four alarm inputs, one relay output and communications wiring.
B.
Alarm inputs shall be individually programmable for their functional state (enabled or disabled), reporting
state (report on or off), active state (high or low), acknowledge mode (manual, momentary or automatic),
automatic acknowledge dwell time control, set and reset action (action when triggered or reset) and
displayed title text. The relay output shall be programmable for its power-on state (on or off), output type
(momentary or latching) and displayed title text.
C.
Programmable titling shall be provided for the camera and every preset position, alarm, relay, and sector.
Titles shall be enabled or disabled individually or globally. The overall position of the titles and display
frame position shall be programmable. The capability to fade titles after a programmable time shall be
provided.
D.
There shall be 79 programmable preset positions available, each having a variable preset solve speed of
1 sec (nominal) and accuracy of 0.23°. The dome’s 360 degree view shall be programmable for a
maximum of 16 sectors. Each sector shall have the capability to be blanked out (no video display). The
number and size of sectors shall be programmable and have a custom title.
E.
There shall be eight tours available with 32 steps per tour. Tour steps shall include preset
positions with speed control, relay control, alarm acknowledge, save/recall camera status, repeat tour, call
another tour, call an autotour and dwell timing control. There shall be two autotours available with 256
pan, tilt and zoom functions per autotour. Timing shall be dynamic or as is actually programmed with the
joystick and push buttons.
F.
Pan and tilt functions shall be externally controlled, continuously variable and programmable to be
enabled or disabled manual pan limits shall be programmable. There shall be an autopan feature and it
shall be programmable for its functional settings (enabled, disabled speed, limits). Maximum manual pan
and tilt speeds shall be programmable. Maximum pan speed shall be 360 degrees/sec and maximum tilt
speed shall be 150 degrees/sec. Pan and tilt speeds shall also be scalable to the zoom setting. The zoom
function speed shall be externally controlled using three settings, low, medium and high.
G.
There shall be two camera/lens formats available, 22X and 23X (day/night). The camera-lens module
shall be a 1/4 inch, high-resolution color type (the 22X with ExView™ technology). Camera sensitivity
shall be between 0.0019 fc (0.02 lux) to 0.002 fc (0.03 lux), depending on the model for 23X and 22X
respectively. The lens on the standard cameras shall have a maximum optical zoom setting of 22X and a
maximum digital zoom setting of 12X for a total zoom setting of 264X and the lens on the day/night
cameras shall have a maximum optical zoom setting of 23X and a maximum digital zoom setting of 12X
for a total zoom setting of 276. Lens focal length shall be 4-88 mm with a maximum aperture of f/1.6 for
the standard cameras and 3.6-82.8 mm for the day/night cameras with a maximum aperture of f/1.6. The
digital zoom shall be programmable for its functional setting (enable/disable). An autoiris function with a
manual override feature and an auto-focus function with functional setting control (enable/disable) shall
also be provided.
H.
In addition, the camera shall provide high level, programmable functions. The autoiris and AGC shall be
adjustable. The shutter speed shall be automatic or manual. The automatic shutter speed shall work with
an auto exposure feature. This feature can be set to operate with a fully automatic shutter speed or a
fixed, selectable, linear speed. These features are called exposure priority or shutter priority. All color
cameras shall have white balance gain using red and blue scales. Backlight compensation shall be
programmable for its relative setting using a tuning value scale. Video line locking shall be provided with
an internal crystal clock or a programmable vertical phase scale.
I.
A real time clock and scheduler shall be available on all models. Up to 64 events shall be able to be
scheduled for action at a programmed time of day. Events that may be scheduled include a preset, turning
a relay on or off, enabling or disabling an alarm, and calling a tour or an autotour
J.
16 individual zoom-scalable programmable privacy masks shall be available.
K.
Programmable azimuth and compass display shall be available. The compass shall be programmed for
absolute North and shall display 8 compass headings (N, NE, E, SE, S, SW, W, NW). Pan and tilt degrees
shall be displayed with a 1° resolution.
L.
Motion detection capability shall be available for the day/night camera. For each preset, there are 6
programmable zones for motion detection. Each zone has 3 sensitivity levels. Programmable actions may
be associated with each detection zone, including calling another preset, turning a relay on or off, and
calling a tour or an autotour.
Model No:
SurveyorVFT
Pressurized
Product Code: See
Table 1
SEC: 3
SPEC:
V004-10
REV: 204
Contractors’ Specification
M.
N.
O.
P.
Q.
R.
S.
The capability to freeze an image during a preset solve shall be available on the day/night cameras. The
control shall be global and affect all preset solves. The freeze of an image during solve has advantages
when recording using a motion compensated recording system (DVR).
The capability to flip (invert) the video image shall be available on the day/night cameras. This feature is
useful when mounting units in an inverted position. All pan/tilt and compass displays are automatically
adjusted for the inverted image.
Auto Baud detection shall be provided on all models operating in RS-422/RS-485 communication mode.
Baud rates supported shall be 4800, 9600 and 19,200 bps. All units shall have automatic detection and
correction of the receive polarity (commands into the dome). The polarity of the transmit signals
(responses from the dome) shall be programmable.
Absolute position control shall be provided on all models operating in RS-422/RS-485 communication
mode. Pan and tilt direct control resolution shall be to 0.125 degrees and zoom direct control resolution
shall be 0.125X magnitude. The capability to adjust the target iris level shall be provided using the
absolute position control feature.
All models shall support interfacing to selected competitors’ control systems. Selection of available
competitors’ protocols shall be provided via DIP switch settings on the unit.
NTCIP 1103 compliant models shall be available (National Transportation Communications for ITS
Protocol).
Multilanguage menu system shall be provided, including English, Spanish, French and Italian.
The pressurized camera dome system shall be Vicon Industries SurveyorVFT pressurized models. Refer to Table 1.
ELECTRICAL
(Pressurized Housing Only)
Input Voltage: 18-32 VAC, 50/60 Hz nominal.
Connector Type:
Current: 3.1 A.
4.5 A with SurveyorVFT (coax,
UTP, fiber); 4.9 A (ViconNet).
Power Consumption: 73 W.
106.6 W with SurveyorVFT (coax,
UTP, fiber); 116.2 W (ViconNet).
Heat Equivalent: 4.15 btu/min (1.05 kg-cal/min).
6.1 btu/min (1.5 kg-cal/min)
with SurveyorVFT (coax, UTP,
fiber); 6.6 btu/min
(1.67 kg-cal/min) (ViconNet).
Note: These figures represent the
conversion of 100% of the
electrical energy to heat. Actual
percentage of heat generated will
be less and will vary from product
to product. These figures are
provided as an aid in determining
the extent of cooling required for
an installation.
Maximum Power
Cable Distance: See Table 2.
Heater Power:
Fan Cooling Rate:
Fuse:
Radio Frequency
Emission Rating:
23-pin, circular, pressure rated.
Mating connector included for
access to all SurveyorVFT signals
including heater/blower, power,
communications and video.
Fiber: ST connector.
ViconNet: RJ-45 connector.
70 W. Will be capable of a coldstart de-icing of the lower dome.
16 cfm (126 ccm).
5 x 20 mm, 4 A 250 VAC, slo-blo.
Surveyor2000 has separate
internal fuses.
FCC Class A
MECHANICAL
Application:
Indoor or outdoor.
Mounting:
Wall mounting with SVFT-PR-WM
Wall Mount or pendant mounting
with SVFT-PR-P Pipe Mount.
Seal Type:
1 “O” ring, fabricated from
neoprene, 0.139 in. (3.5 mm)
cord diameter and an EPDM
(rubber) gasket.
Table 2: Maximum Power Cable Distance
Distance ft (m)
Wire Size
(AWG)
Annealed
Copper Wire
24 VAC
20
Coax, Fiber,
UTP
65 (20)
18
16
28 VAC
50 (15)
Coax, Fiber,
UTP
110 (34)
101 (31)
84 (25)
172 (52)
156 (48)
163 (50)
150 (46)
275 (84)
250 (76)
ViconNet
ViconNet
100 (30)
14
260 (79)
240 (73)
440 (134)
400 (122)
12
406 (124)
375 (114)
688 (210)
625 (190)
Model No:
SurveyorVFT
Pressurized
Product Code: See
Table 1
SEC: 3
SPEC:
V004-10
REV: 204
5
Technical Information
Mount Size/Thread:
Dimensions:
Weight:
Construction:
Color:
IP Rating:
Shipping Dimensions:
Shipping Weight:
Shipping Volume:
4 threaded hole pattern (3.75 in./
95 mm square) on top used for
mount attachment. Each
threaded hole is 1/4-20 x 0.41 in.
(10 mm) deep.
Gasket provided to seal top
interface.
See Figure.
Pendant
Housing Diameter (D1):
13.0 in. (330 mm).
Dome Diameter (D2):
9.8 in. (249 mm).
Housing Diameter (H1):
8.25 in. (210 mm).
Total Height (H2):
14.0 in. (355 mm).
Operating Pressure:
Relief Pressure:
Low Pressure Switch:
Surge Protection:
(SurveyorVFT Drive Mechanism Only)
Drive Type:
Camera Types:
Input Voltage:
Standard Connector
Types:
12.0 lb (5.4 kg).
16.5 lb (7.5 kg) with SurveyorVFT
included.
Plastic, aluminum and stainless
steel.
White housing, black housing and
trim ring.
Video Output
Impedance:
Fuse:
Radio
Emission Rating:
Maintained
Temperature
and Humidity Range:
6
Units available in color and
day/night (NTSC/PAL) formats
and a variety of zoom and feature
capabilities.
18-32 VAC.
Video Out: See version type.
Power: 2-position removable
screw terminal block.
Control Input/Output: See version
type.
Relay Output: See version type.
Alarm Input: 8-position removable
screw terminal block.
75 ohms.
F1: 2AG, 1.6 A 250 VAC slo-blo.
F2: 2AG, 2.5 A 250 VAC slo-blo.
FCC Class A.
OPERATIONAL
Video Pan View:
360°.
Height: 19.5 in (495 mm).
Width: 16 in. (406 mm).
Depth: 16 in. (406 mm).
Video Tilt View:
-2.5° (-2.5° above horizon) to
92.5° (-2.5° past vertical).
18.5 lb (8.4 kg).
Autopan Speed:
3
Pan Speed:
3
2.9 ft (0.08 m ).
Tilt Speed:
Schraeder type valve used to
fill and drain housing with dry
nitrogen gas. Relief valve
automatically relieves pressure at
7 psi (0.48 atm).
1 - 5 psi (0.07 - 0.34 atm or bars)
maximum.
7 psi (0.48 atm or bars)
maximum.
Zoom and Focus
Speed:
Sectoring:
Preset Capabilities:
Preset Solving
Speed:
A normally open (NO) switch
output available on connector for
use as external alarm.
Preset Accuracy
(Pan & Tilt):
Tour Capabilities:
Video level is clamped at 6.5 V
maximum. Power is current
limited by a 1-watt in-line resistor.
ENVIRONMENTAL
Ambient Temperature
and Humidity Range:
Electrical motorized pan and tilt
with electronic control.
IP67.
OPERATIONAL
Pressurization:
ELECTRICAL
-30° F (-34° C) to 165° F (74° C)
in accordance with NEMA 2.1.5.1
STD2; -40 to 132°F (-40 to 55°C)
continuous rotation.
Up to 100% relative humidity,
condensing.
Variable, 0.1 to 360°/sec.
Variable, 0.1 to 42°/sec;
enable/disable.
Variable, 0.2 to 150°/sec.
Less than 1.8 sec from end to
end.
16 max, programmable for size
and titling; capability to be
blanked out.
79 individual programmable
preset positions.
1 sec nominal.
0.23° maximum.
8 tours available.
32 programmable events per
tour. Events may be preset
positions with speed control,
alarm acknowledge, dwelltime
control, relay control, call
autotours, tour repeat or another
tour, save/recall camera status.
14° F (-10° C) to 140° F (60° C)
maximum.
Up to 90% relative,
noncondensing.
Model No:
SurveyorVFT
Pressurized
Product Code: See
Table 1
SEC: 3
SPEC:
V004-10
REV: 204
Technical Information
Autotour Capabilities:
Alarm Capabilities:
Relay Output
Capabilities:
Control Display:
Privacy Masks:
Screen Titling
Capabilities:
Scheduling:
Multilanguage Menu:
Day/Night (23X)
Features:
2 autotours available
with 256 pan, tilt and zoom
functions per autotour.
Programming is done in real time
with joystick and push buttons.
4 alarm inputs, individually
programmable.
Functional state enable/disable.
Report state (report on/off).
Active state (high/low).
Mode (manual, momentary or
automatic) with programmable
dwell time control.
Set and reset action (preset
solve, relay on/off, tour, autotour.
Alarm titling.
1 relay output.
Power-on state definition (on/off).
Output type definition (momentary
or latching).
Relay function status titling.
Resistive Load: 0.3A @125 VAC;
1.5A @30 VDC.
Inductive Load: 0.15A @
125 VAC; 0.75A @ 30 VDC.
On-screen, menu-driven system
allowing full configuration of the
dome.
16 individual, programmable,
zoom-scalable.
Programmable for camera,
preset, sector, relay and alarms.
Camera: 1 for each.
Preset: 79 maximum.
Sector: 16 maximum.
Alarm: 4 maximum.
Individual type date and time
enable/disable; 20 characters
maximum.
Selectable position.
Three text sizes for top 2 lines.
Fade capability.
Compass/azimuth, 8 compass
headings (N, NE, E, SE, S, SW,
W, NW).
Real time clock allows scheduling
of up to 64 events, including
presets, relays, alarms, tours or
autotours.
English, Spanish, French and
Italian.
6 programmable motion
detection zones with 3 sensitivity
levels; image freeze during preset
solve; flip (invert) video image.
Model No:
SurveyorVFT
Pressurized
Auto Baud:
Absolute Position
Control:
Competitive
Protocols:
Auto baud detection in RS-22/
RS-485 mode; 4800, 9600,
19,200 bps baud rates
supported.
Available in RS-422/RS-485
mode.
Pan/tilt: 0.125°; zoom: 0.125X.
DIP switch selectable.
COAXIAL/UTP VERSIONS
Control Protocol
Hardware:
Control Protocol
Software:
Control Protocol
Format (selectable via
DIP switch 2):
Vicon: Vicon’s NOVA V1422
Matrix Switcher, V1300, V1344,
V1466, V1400 and 1500 series
NOVA CPUs, V1400X-DVC
System Console and V1300XRVC desk-top keypad or
V1300X-RVC rack-mounted
keypad.
Vicon’s ProTech software (or
compatible) or Surveyor Direct
Control program runs on a
standard PC type computer with
an RS-422/485 half duplex
protocol interface.
Vicon: RS-422 or RS-485
protocol. Communication is
simplex or half duplex operation
at 4800, 9600 or 19,200 baud or
Vicon’s enhanced VicoaxII
protocol (superimposed data on
composite video signal)
automatically detected upon
power up.
RS-485 protocol utilizes full tristate outputs for daisy chain
capability.
Pelco: Pelco D Protocol (3/2/99);
RS-485 N.8.1, simplex 2400 bps,
duplex 4800 bps.
Sensormatic/AD: RS-422/RS485 communication protocols
user’s guide Rev. A (csd 05/00);
RS-422/RS-485 duplex N.8.1
4800 bps. May require RS-422
converter, RCSN422.
Ultrak: (Released in future.) KD6,
KD6-Z control protocols; RS-485
simplex E.8.1, 9600 bps.
Philips: (Released in future.)
Receiver/Driver/Auto Dome
control code protocol;
RS-232 simplex N.8.1, 2400 or
9600 bps.
Product Code: See
Table 1
SEC: 3
SPEC:
V004-10
REV: 204
7
Technical Information
Kalatel: (Released in future.)
Non-repeating transmit
commands; RS-422 simplex
N.8.1, 9600 bps.
Cohu: (Released in future.) MPC
System RS-422 interface; RS422 duplex N.8.1, 9600 bps.
Panasonic: (Released in future.)
Panasonic conventional and new
camera protocol.
Note: All companies make
changes and improvements in
their products. Because this
product can interface with
equipment not manufactured by
Vicon, there is a possibility that
the interface protocols may have
changed since Vicon tested this
product with the interfacing
equipment. Vicon recommends
purchasing a single unit for bench
testing prior to purchasing and
installing this product in quantity.
Connector Types:
Video Out:
Coax: BNC-F.
UTP: 3-position removable screw
terminal block.
Control Input/Output:
8-position removable screw
terminal block.
Relay Output: 8-position
removable screw terminal block.
FIBER-OPTIC VERSION
Fiber Optic Receiver
Specs:
Connector Types:
Video:
I/O Level: 1 V p-p.
I/O Impedance: 75 ohms.
Bandwidth: 8 MHz.
Differential Gain: 5%.
Differential Phase: 5°.
SNR: 60dB.
Data:
Data Rate: Up to 19.2 Kbps.
Optical:
Wavelength: 850/1300 nm.
Loss Budget (62.5/125u): 12 dB.
Connector: ST.
Video Out: ST type.
Control Input/Output: ST type.
Relay Output: 8-position
removable screw terminal block.
VICONNET VERSION (LAN/TCP/IP)
Communication
Protocol Hardware: Vicon’s Kollector Elite Digital
Recorders and ViconNet
Workstations.
LAN Interface:
Connector Types:
100 Mbps.
Video Out: RJ-45 jack.
Network: Ethernet 100Base-T
RJ-45 jack. 10/100 Mbps
required for network connection.
Audio Input/Output: RCA jacks.
Relay Output: 3-position
removable screw terminal block.
CAMERA/LENS
Specifications:
Refer to Table 2.
VIDEO TRANSMISSION
Maximum Distances:
Coax: 1100 ft (350 m), cable
dependant.
Vicoax: 1500 ft up to 140° F
(60° C); 1000 ft up to 165° F
(74° C). RG59.
UTP: up to 3000 ft (915 m),
model dependant.
Fiber: 1 mile min.; longer
distances available dependant on
cable quality.
ViconNet: 100 meters without
repeater.
H1
H2
D1
D2
8
Model No:
SurveyorVFT
Pressurized
Product Code: See
Table 1
SEC: 3
SPEC:
V004-10
REV: 204
Technical Information
Model Numbers
SVFT-PR22
SVFT-PR22C
SVFT-PR23
SVFT-PR23C
8711
8711-01
Product Codes
Specifications
8710
8710-01
Formats
NTSC
PAL
NTSC
PAL
Type
Color
Color
Color
Color
Optical Zoom
22X
22X
23X
23X
Digital Zoom
12X
12X
12X
12X
Total Zoom
264X
264X
276X
276X
Zoom Speed
Tele-Wide: 3.9 sec
Tele-Wide: 3.9 sec
Tele-Wide: 3.9 sec
Tele-Wide: 3.9 sec
Image Device
1/4-inch interline transfer
CCD
1/4-inch interline transfer
CCD
1/4-inch interline transfer
CCD
1/4-inch interline transfer
CCD
Picture Elements
768(H) x 494 (V),
380,000 pixels
752(H) x 582 (V),
438,000 pixels
768(H) x 494 (V),
380,000 pixels
847(H) x 532 (V),
490,000 pixels
Scanning System
2:1 interlace, 525 lines
60 fields/sec
2:1 interlace, 625 lines
50 fields/sec
2:1 interlace, 525 lines
60 fields/sec
2:1 interlace, 625 lines
50 fields/sec
Sensitivity
0.002 fc (0.03 lux) at 40 IRE,
f/1.6, auto 1/4s
0.002 fc (0.03 lux) at 40 IRE,
f/1.6, auto 1/3s
0.0019 fc (0.02 lux) at
40 IRE, f/1.6, auto 1/4s
0.0019 fc (0.02 lux) at
40 IRE, f/1.6, auto 1/5s
Horizontal Resolution
470 TV lines (color)
470 TV lines (color)
470 TV lines (color)
530 TV lines (color)
S/N Ratio
More than 50 dB
More than 50 dB
More than 50 dB
More than 50 dB
Synchronization
Internal/External
(line lock on AC line)
Internal/External
(line lock on AC line)
Internal/External
(line lock on AC line)
Internal/External
(line lock on AC line)
Automatic Gain Control
(AGC)
Adjustable to 25 dB
Adjustable to 32 dB
Adjustable to 30 dB
Adjustable to 30 dB
Backlight Compensation
Software adjustable
background video level
Software adjustable
background video level
Software adjustable
background video level
Software adjustable
background video level
Iris Control
Automatic/Manual
Automatic/Manual
Automatic/Manual
Automatic/Manual
Video Focus
Automatic/Manual
1.0 m (tele ) - 0.01 m (wide)
Automatic/Manual
1.0 m (tele ) - 0.01 m (wide)
Automatic/Manual
1.0 m (tele ) - 0.01 m (wide)
Automatic/Manual
1.0 m (tele ) - 0.01 m (wide)
White Balance
Automatic/Manual
Red/Blue Gain Level
Automatic/Manual
Red/Blue Gain Level
Automatic/Manual
Red/Blue Gain Level
Automatic/Manual
Red/Blue Gain Level
Shutter Speed
Auto(DSS): 1/2-1/4000
Man:1/2-1/30K sec
Auto(DSS): 1/1.5-1/4000
Man:1/1.5-1/30K sec
Auto(DSS): 1/2-1/60
Man:1/2-1/30K sec
Auto(DSS): 1/1.5-1/50
Man:1/1.5-1/30K sec
Input Voltage
9.0 VDC ±0.5 V
9.0 VDC ±0.5 V
9.0 VDC ±0.5 V
9.0 VDC ±0.5 V
Power Consumption
3.3 W max
3.3 W max
3.6 W nom.
3.6 W nom.
Dimensions H x W x D
2.4 x 2.0 x 3.5 in.
60 x 50 x 88.9 mm
2.4 x 2.0 x 3.5 in.
60 x 50 x 88.9 mm
2.4 x 2.0 x 3.5 in.
60 x 50 x 88.9 mm
2.4 x 2.0 x 3.5 in.
60 x 50 x 88.9 mm
Weight
0.5 lb (0.23 kg)
0.5 lb (0.23 kg)
0.5 lb (0.23 kg)
0.5 lb (0.23 kg)
Focal Length
4 - 88 mm
4 - 88 mm
3.6 - 82.8 mm
3.6 - 82.8 mm
Aperture max
f/1.6
f/1.6
f/1.6
f/1.6
Horizontal Angle of View
47° wide, 2.2° tele
47° wide, 2.2° tele
47° wide, 2.2° tele
47° wide, 2.2° tele
Lenses
Table 3: Camera/Lens Specifications
Model No:
SurveyorVFT
Pressurized
Product Code: See
Table 1
SEC: 3
SPEC:
V004-10
REV: 204
9
Technical Information
89 Arkay Drive
Hauppauge, NY 11788
www.vicon-cctv.com
Copyright  2004 Vicon Industries, Inc. All rights reserved
TEL: 631-952-2288
FAX: 631-951-2288
TOLL FREE: 800-645-9116
Vicon and its logo are registered trademarks of Vicon Industries, Inc.
10
Download PDF