INSTALLATION MANUAL
AIR CONDITIONER (SPLIT TYPE)
ENGLISH
ESPAÑOL
FRANÇAIS
PORTUGUÊS
PУCСКИЙ
TÜRKÇE
Indoor unit
RAS-18, 22N3KV(R) Series
Outdoor unit
RAS-18, 22N3AV Series
1110651805
Book 1110651805.indb 1
5/29/12 10:45 AM
EN
CONTENTS
ES
CONTENIDOS
PRECAUTIONS FOR SAFETY................................................................................ 1
PRECAUCIONES SOBRE SEGURIDAD ................................................................ 1
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS ........................ 3
 Optional Installation Parts .................................................................................... 3
DIAGRAMA DE INSTALACIÓN DE LA UNIDAD INTERIOR Y EXTERIOR ........... 3
 Piezas de Instalación Opcional ............................................................................ 3
INDOOR UNIT .......................................................................................................... 4
 Installation Place .................................................................................................. 4
 Cutting a Hole and Mounting Installation Plate .................................................... 4
 Wiring Connection ................................................................................................ 4
 How to Connect Remote Controller for Wire Operation ....................................... 5
 Piping and Drain Hose Installation ....................................................................... 6
 Indoor Unit Fixing ................................................................................................. 7
 Drainage ............................................................................................................... 7
UNIDAD INTERIOR ................................................................................................. 4
 Lugar de Instalación ............................................................................................. 4
 Corte de un Orificio y Montaje de la Placa de Instalación ................................... 4
 Conexión de Cables ............................................................................................. 4
 Cómo conectar el mando a distancia para la función de cableado...................... 5
 Instalación la Tubería y el Tubo de Desagüe ....................................................... 6
 Instalación de la Unidad Interior ........................................................................... 7
 Drenaje ................................................................................................................. 7
OUTDOOR UNIT ...................................................................................................... 7
 Installation Place .................................................................................................. 7
 Precautions about Installation in Regions with Snowfall and Cold
Temperatures ....................................................................................................... 7
 Refrigerant Piping Connection ............................................................................. 8
 Evacuating ........................................................................................................... 8
 Wiring Connection ................................................................................................ 8
 Electrical Work ..................................................................................................... 9
UNIDAD EXTERIOR ................................................................................................ 7
 Lugar de Instalación ............................................................................................. 7
 Precauciones sobre Instalación en Regiones con Nieve y
Temperaturas Frías .............................................................................................. 7
 Conexión de la Tubería Refrigerante ................................................................... 8
 Evacuación ........................................................................................................... 8
 Conexión de Cables ............................................................................................. 8
 Trabajo Eléctrico ................................................................................................. 9
OTHERS................................................................................................................... 9
 Gas Leak Test ...................................................................................................... 9
 Remote Control A-B Selection ............................................................................. 9
 Test Operation ..................................................................................................... 9
 Auto Restart Setting ............................................................................................ 9
OTROS ..................................................................................................................... 9
 Comprobación de Fugas ...................................................................................... 9
 Mando a distancia A-B Selección ......................................................................... 9
 Prueba de Operación ........................................................................................... 9
 Ajuste de Reinicio Automático .............................................................................. 9
FR
SOMMAIRE
PT
ÍNDICE
MESURES DE SÉCURITÉ....................................................................................... 1
PRECAUÇÕES RELATIVAS A SEGURANÇA ........................................................ 1
PLAN D’INSTALLATION DES UNITÉS INTÉRIEURE ET EXTÉRIEURE .............. 3
 Pièces d’Installation en Option ............................................................................ 3
ESQUEMA DE INSTALAÇÃO DAS UNIDADES INTERIOR E EXTERIOR ............ 3
 Peças de Instalação Opcionais ............................................................................ 3
UNITÉ INTÉRIEURE ................................................................................................ 4
 Endroit d’Installation ............................................................................................. 4
 Ouverture du Trou et Montage de la Plaque d’Installation .................................. 4
 Connexion des Câbles ......................................................................................... 4
 Comment se connecter avec la télécommande pour un fonctionnement
par câble............................................................................................................... 5
 Installation de la Conduite et du Tuyau de Purge ............................................... 6
 Installation de l’Unité Intérieure ............................................................................ 7
 Drainage .............................................................................................................. 7
UNIDADE INTERIOR ............................................................................................... 4
 Local de Instalação .............................................................................................. 4
 Cortar um Orifício e Montar a Placa de Instalação .............................................. 4
 Ligações Eléctricas .............................................................................................. 4
 Como ligar o controlo remoto para funcionamento com cabo ............................. 5
 Instalação da Tubagem e do Tubo Flexível de Dreno.......................................... 6
 Colocação da Unidade Interior ............................................................................. 7
 Drenagem............................................................................................................. 7
UNITÉ EXTÉRIEURE ............................................................................................... 7
 Endroit d’Installation ............................................................................................. 7
 Précautions à prendre pour l’installation dans les régions sujettes aux
chutes de neige et aux températures froides ....................................................... 7
 Connexion du Tuyau Réfrigérant ......................................................................... 8
 Evacuation............................................................................................................ 8
 Connexion des Câbles ......................................................................................... 8
 Travaux Electriques.............................................................................................. 9
AUTRES ................................................................................................................... 9
 Test de Fuite Gaz ................................................................................................. 9
 Sélection de télécommande A-B .......................................................................... 9
 Opération du Test ................................................................................................. 9
 Réglage de la Remise en Marche Automatique ................................................... 9
RU
СОДЕРЖАНИЕ
UNIDADE EXTERIOR .............................................................................................. 7
 Local de Instalação .............................................................................................. 7
 Precauções na instalação em regiões com queda de neve e
temperaturas negativas ........................................................................................ 7
 Ligação das Condutas de Refrigeração ............................................................... 8
 Purga de Ar .......................................................................................................... 8
 Ligações Eléctricas .............................................................................................. 8
 Trabalhos de Electricidade ................................................................................... 9
OUTROS .................................................................................................................. 9
 Teste de Fugas de Gás ........................................................................................ 9
 Selecção A-B do telecomando ............................................................................. 9
 Execução do Teste ............................................................................................... 9
 Definindo de Reiniciação Automática ................................................................... 9
TR
İÇİNDEKİLER
MEPЫ БEЗOПACHOCTИ ....................................................................................... 1
GÜVENLİK ÖNLEMLERİ ........................................................................................ 1
СХЕМА УСТАНОВКИ ВНУТРЕННЕГО И НАРУЖНОГО БЛОКОВ ................... 3
 Oпционaльныe Уcтaновочныe Чacти ................................................................ 3
İÇ VE DIŞ ÜNITENIN MONTAJ ŞEMASI ................................................................ 3
 İsteğe Bağlı Montaj Parçaları ............................................................................... 3
BHУTPEHHИЙ БЛOК ............................................................................................. 4
 Mecто Уcтaновки ................................................................................................ 4
 Пpоpeзaниe Отвepcтия и Монтaж Уcтaновочной Плacтины............................... 4
 Элeктpичecкиe Cоeдинeния ............................................................................. 4
 Как подключить ПДУ к проводу ....................................................................... 5
 Уcтaновкa Tpyбопpоводов и Дpeнaжной Tpyбки ............................................. 6
 Уcтaновкa Bнyтpeннeго Блокa.......................................................................... 7
 Дpeнaж ................................................................................................................ 7
İÇ ÜNİTE .................................................................................................................. 4
 Montaj Yeri ........................................................................................................... 4
 Bir Delik Açılması ve Montaj Plakasının Yerleştirilmesi ........................................ 4
 Kablo Bağlantısı ................................................................................................... 4
 Kablolu Kullanım İçin Uzaktan Kumanda Bağlantısı Nasıl Yapılır ........................ 5
 Boruların Bağlanması ve Boşaltma Hortumunun Monte edilmesi ............................... 6
 İç Ünitenin Takılması ............................................................................................ 7
 Su Boşaltma ......................................................................................................... 7
HAPУЖHЫЙ БЛOК ................................................................................................ 7
 Mecто Уcтaновки ................................................................................................ 7
 Меры безопасности при установке в регионах, в которых возможно
выпадение снега и низкие температуры ............................................................. 7
 Подcоeдинeниe Tpyбопpоводa для Xлaдaгeнтa .............................................. 8
 Удaлeниe Воздyxa .............................................................................................. 8
 Элeктpичecкиe Cоeдинeния ............................................................................. 8
 Элeктpомонтaжныe Рaботы ............................................................................. 9
DIŞ ÜNİTE ................................................................................................................ 7
 Montaj Yeri ........................................................................................................... 7
 Karlı ve Soğuk Bölgelerde Montaj İle İlgili Önlemler ............................................ 7
 Soğutma Maddesi Boru Bağlantısı ....................................................................... 8
 Boşaltma .............................................................................................................. 8
 Kablo Bağlantısı ................................................................................................... 8
 Elektrik İşi ............................................................................................................. 9
ДPУГИE ................................................................................................................... 9
 Пpовepкa Отcyтcтвия Утeчки Гaзa ................................................................... 9
 Выбор А-В на пульте ДУ .................................................................................... 9
 Пpобнaя Экcплyaтaция ...................................................................................... 9
 Уcтaновкa Aвтомaтичecкого Повтоpного Пycкa ............................................. 9
Book 1110651805.indb 2
DİĞERLERİ .............................................................................................................. 9
 Gaz Kaçağı Testi .................................................................................................. 9
 Uzaktan Kumanda ile A-B Seçimi ........................................................................ 9
 Test İşlemi ............................................................................................................ 9
 Otomatik Yeniden Başlama Ayarı ......................................................................... 9
5/29/12 10:45 AM
PRECAUTIONS FOR SAFETY
• Before installation, please read these precautions for safety carefully.
• Be sure to follow the precautions provided here to avoid safety risks. The symbols and their meanings are shown below.
WARNING : It indicates that incorrect use of this unit may cause severe injury or death.
CAUTION : It indicates that incorrect use of this unit may cause personal injury (*1), or property damage (*2).
*1: Personal injury means a slight accident, burn, or electrical shock which does not require admission or repeated hospital treatment.
*2: Property damage means greater damage which affects assets or resources.
EN
For general public use
Power supply cord of parts of appliance for outdoor use shall be at least polychloroprene sheathed flexible cord (design H07RN-F) or cord designation
60245 IEC66 (1.5 mm2 or more). (Shall be installed in accordance with national wiring regulations.)
CAUTION
New refrigerant air conditioner installation
ES
FR
IT
• THIS AIR CONDITIONER USES THE NEW HFC REFRIGERANT (R410A), WHICH DOES NOT DESTROY THE OZONE LAYER.
R410A refrigerant is apt to be affected by impurities such as water, oxidizing membranes, and oils because the pressure of R410A refrigerant is approx.
1.6 times of refrigerant R22. As well as the adoption of this new refrigerant, refrigerating machine oil has also been changed. Therefore, during installation
work, be sure that water, dust, former refrigerant, or refrigerating machine oil does not enter the refrigeration cycle of a new-refrigerant air conditioner.
To avoid mixing refrigerant and refrigerating machine oil, the sizes of charging port connecting sections on the main unit are different from those for the
conventional refrigerant, and different size tools are also required. For connecting pipes, use new and clean piping materials with high pressure withstand
capabilities, designed for R410A only, and ensure that water or dust does not enter. Moreover, do not use any existing piping as its pressure withstand
may be insufficient and may contain impurities.
DE
PT
PL
CZ
DANGER
• FOR USE BY QUALIFIED PERSONS ONLY.
• TURN OFF MAIN POWER SUPPLY BEFORE ATTEMPTING ANY ELECTRICAL WORK. MAKE SURE ALL POWER SWITCHES ARE OFF.
FAILURE TO DO SO MAY CAUSE ELECTRIC SHOCK.
• CONNECT THE CONNECTING CABLE CORRECTLY. IF THE CONNECTING CABLE IS CONNECTED WRONGLY, ELECTRIC PARTS MAY BE
DAMAGED.
• CHECK THE EARTH WIRE THAT IT IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION.
• DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS.
FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION.
• TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD, PLACE THE UNIT WELL AWAY (MORE THAN 2 M) FROM HEAT
SOURCES SUCH AS RADIATORS, HEATERS, FURNACE, STOVES, ETC.
• WHEN MOVING THE AIR CONDITIONER FOR INSTALLING IT IN ANOTHER PLACE AGAIN, BE VERY CAREFUL NOT TO GET THE SPECIFIED
REFRIGERANT (R410A) WITH ANY OTHER GASEOUS BODY INTO THE REFRIGERATION CYCLE. IF AIR OR ANY OTHER GAS IS MIXED IN THE
REFRIGERANT, THE GAS PRESSURE IN THE REFRIGERATION CYCLE BECOMES ABNORMALLY HIGH AND IT RESULTINGLY CAUSES BURST
OF THE PIPE AND INJURIES ON PERSONS.
• IN THE EVENT THAT THE REFRIGERANT GAS LEAKS OUT OF THE PIPE DURING THE INSTALLATION WORK, IMMEDIATELY LET FRESH AIR
INTO THE ROOM. IF THE REFRIGERANT GAS IS HEATED BY FIRE OR SOMETHING ELSE, IT CAUSES GENERATION OF POISONOUS GAS.
RU
CR
HU
TR
NL
GR
SV
FI
NO
DK
RO
BG
EE
LV
SK
SI
1
Book 1110651805.indb 1
5/30/12 2:42 PM
WARNING
• Never modify this unit by removing any of the safety guards or bypassing any of the safety interlock switches.
• Installation work must be requested from the supplying retail dealership or professional vendors. Self-installation may cause water leakage, electrical
shock, or fire as a result of improper installation.
• Specified tools and pipe parts for model R410A are required, and installation work must be done in accordance with the manual. HFC type refrigerant
R410A has 1.6 times more pressure than that of conventional refrigerant (R22). Use the specified pipe parts, and ensure correct installation, otherwise
damage and/or injury may be caused. At the same time, water leakage, electrical shock, and fire may occur.
• Be sure to install the unit in a place which can sufficiently bear its weight. If the load bearing of the unit is not enough, or installation of the unit is
improper, the unit may fall and result in injury.
• Electrical work must be performed by a qualified electrical engineer in accordance with the code governing such installation work, internal wiring
regulations, and the manual. A dedicated circuit and the rated voltage must be used. Insufficient power supply or improper installation may cause
electrical shock or fire.
• Use a cabtyre cable to connect wires in the indoor/outdoor units. Midway connection, stranded wire, and single-wire connections are not allowed.
Improper connection or fixing may cause a fire.
• Wiring between the indoor unit and outdoor units must be well shaped so that the cover can be firmly placed. Improper cover installation may cause
increased heat, fire, or electrical shock at the terminal area.
• Be sure to use only approved accessories or the specified parts. Failure to do so may cause the unit to fall, water leakage, fire or electrical shock.
• After the installation work, ensure that there is no leakage of refrigerant gas. If the refrigerant gas leaks out of the pipe into the room and is heated by
fire or something else from a fanheater, stove or gas range, it causes generation of poisonous gas.
• Make sure the equipment is properly earthed. Do not connect the earth wire to a gas pipe, water pipe, lightning conductor, or telephone earth wire.
Improper earth work may be the cause of electrical shock.
• Do not install the unit where flammable gas may leak. If there is any gas leakage or accumulation around the unit, it can cause a fire.
• Do not select a location for installation where there may be excessive water or humidity, such as a bathroom. Deterioration of insulation may cause
electrical shock or fire.
• Installation work must be performed following the instructions in this installation manual. Improper installation may cause water leakage, electrical shock
or fire. Check the following items before operating the unit.
- Be sure that the pipe connection is well placed and there are no leaks.
- Check that the service valve is open. If the service valve is closed, it may cause overpressure and result in compressor damage. At the same time, if
there is a leak in the connection part, it may cause air suction and overpressure, resulting in damage to the unit or injury.
• In a pump-down operation, be sure to stop the compressor unit before removing the refrigerant pipe. If removing the refrigerant pipe while the
compressor is operating with the service valve opened, it may cause air suction and overpressure, resulting in damage to the unit or injury.
• Do not modify the power cable, connect the cable midway, or use a multiple outlet extension cable. Doing so may cause contact failure, insulation
failure, or excess current, resulting in fire or electrical shock.
• Appliance shall be installed in accordance with national wiring regulation.
If you detect any damage do not install the unit. Contact your supplying dealer immediately.
• Do not use any refrigerant different from the one specified for complement or replacement.
Otherwise, abnormally high pressure may be generated in the refrigeration cycle, which may result in a failure or explosion of the product or an injury to
your body.
CAUTION
• Exposure of unit to water or other moisture before installation could result in electric shock. Do not store it in a wet basement or expose to rain or water.
• After unpacking the unit, examine it carefully for possible damage.
• Do not install in a place that can increase the vibration of the unit. Do not install in a place that can amplify the noise level of the unit or where noise and
discharged air might disturb neighbors.
• Please read this installation manual carefully before installing the unit. It contains further important instructions for proper installation.
• This appliance must be connected to the main power supply by means of a circuit breaker depending on the place where the unit is installed. Failure to do
so may cause electrical shock.
• Follow the instructions in this installation manual to arrange the drain pipe for proper drainage from the unit. Ensure that drained water is discharged.
Improper drainage can result in water leakage, causing water damage to furniture.
• Tighten the flare nut with a torque wrench using the prescribed method. Do not apply excess torque. Otherwise, the nut may crack after a long period of
usage and it may cause the leakage of refrigerant.
• Wear gloves (heavy gloves such as cotton gloves) for installation work. Failure to do so may cause personal injury when handling parts with sharp edges.
• Do not touch the air intake section or the aluminum fins of the outdoor unit. It may cause injury.
• Do not install the outdoor unit in a place which can be a nest for small animals. Small animals could enter and contact internal electrical parts, causing a
failure or fire.
• Request the user to keep the place around the unit tidy and clean.
• Make sure to conduct a trial operation after the installation work, and explain how to use and maintain the unit to the customer in accordance with the
manual. Ask the customer to keep the operation manual along with the installation manual.
• The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual.
REQUIREMENT OF REPORT TO THE LOCAL POWER SUPPLIER
Please make absolutely sure that the installation of this appliance is reported to the local power supplier before installation. If you experience any problems
or if the installation is not accepted by the supplier, the service agency will take adequate countermeasures.
2
Book 1110651805.indb 2
5/30/12 2:42 PM
50 mm or more
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
Pure Air Purifier
N3KVR
only
170
mm
or m
ore
For the rear left and left piping
1 Installation
Hook
plate
Wall
EN
Hoo
170
k
mm
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
or m
ore
ES
FR
Air fi
(At
Do not allow the drain hose to get slack.
lter
tac
h to
the
fron
t pa
Pu
re
Air
5 Filter
Pu
.)
rifie
r
Make sure to run the drain hose sloped
downward.
8
Flat head
wood screw
6
holder
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
8
2
600 mm or more
&
Vinyl tape
Apply after carrying
out a drainage test.
Flat head
wood screw
Wireless remote
control
Flat head
wood screw
The provided Remote Controller is a
wireless type, which also can be used as
a wire.
Please see “How to Connect The Remote
Controller for Wired Operation”, in case of
wired control is required.
When installing the outdoor unit, leave open
in at least two of direction (A), (B), (C) and
(D) shown in the figure on the right.
100
mm
or
(C)
CZ
RU
Right
CR
Rear
right
(D)
100
mm
Bottom
right
ore
or m
Left
Rear
left
Bottom left
Insulate the refrigerant pipes separately
with insulation, not together.
re
ore
rm
mo
m
600
(B)
Remark :
• Detail of accessory and installation parts can see in the
accessory sheet.
• Some pictures might be different from the actual parts.
HU
Saddle
mo
600
PT
PL
4 Remote control
3 Batteries
Battery cover
DE
nel
Filter
(
IT
Cut the piping
hole sloped
slightly.
Shield pipe
Extension
drain hose
(Not available,
provided by installer)
mm
or
(A)
TR
NL
GR
mo
re
8 mm thick heat resisting
polyethylene foam
SV
FI
Optional Installation Parts
A
Parts name
Refrigerant piping
Liquid side
: dia. 6.35 mm
Gas side
: dia. 12.70 mm
Q’ty
One
each
108 mm
125 mm
RO
BG
.2
One
each
DK
Air inlet
dia
Putty, PVC tapes
86 mm
C
1
320 mm
Pipe insulating material
(polyethylene foam, 8 mm thick)
5m
m
28 mm
B
NO
• Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be
exposed to a strong wind.
• Use dia. 8 mm or dia. 10 mm anchor bolts and nuts.
• If it is necessary to drain the defrost water, attach drain nipple 9 and cap
water proof ! to the bottom plate of the outdoor unit before installing it.
102 mm
Part
code
Fixing bolt arrangement of outdoor unit
EE
Air outlet
90 mm
600 mm
LV
Drain outlet
SK
SI
3
Book 1110651805.indb 3
5/30/12 2:42 PM
INDOOR UNIT
Mounting the installation plate
Hook
7RXQLWRXWOLQH
PP
7RXQLWRXWOLQH
PP
di
a.
65
m
m
2IIVHWPPIURPWKHOHIWVLGHHGJHLV
WKHFHQWHURISLSHKROH
7RXQLWRXWOLQH
PP
2IIVHWPPIURPWKHULJKWVLGHHGJHLV
WKHFHQWHURISLSHKROH
7RXQLWRXWOLQH
PP
Hook
CAUTION
Thread
7 Mounting
Screw
Indoor unit
1
Pipe hole
(dia. 65mm)
Installation plate
Weight
When the installation plate is directly mounted
on the wall
Remote control
1. Securely fit the installation plate onto the wall by screwing it in the upper
and lower parts to hook up the indoor unit.
2. To mount the installation plate on a concrete wall with anchor bolts, use the
anchor bolt holes as illustrated in the below figure.
3. Install the installation plate horizontally in the wall.
• A place where there are no obstacles such as a curtain that may block the
signal from the remote control.
• Do not install the remote control in a place exposed to direct sunlight or
close to a heating source such as a stove.
• Keep the remote control at least 1 m apart from the nearest TV set or stereo
equipment. (This is necessary to prevent image disturbances or noise
interference.)
• The location of the remote control should be determined as shown below.
(Side view)
Hook
Pipe hole
• Direct sunlight to the indoor unit’s wireless receiver should be avoided.
• The microprocessor in the indoor unit should not be too close to RF
noise sources.
(For details, see the owner’s manual.)
Indoor unit
Anchor bolt holes
• A place which provides the spaces around the indoor unit as shown in the
diagram
• A place where there are no obstacles near the air inlet and outlet
• A place which allows easy installation of the piping to the outdoor unit
• A place which allows the front panel to be opened
• The indoor unit shall be installed as top of the indoor unit comes to at least
2 m height. Also, it must be avoided to put anything on the top of the indoor
unit.
2 m or more from floor
Installation Place
CAUTION
When installing the installation plate with a mounting screw, do not use
the anchor bolt holes. Otherwise, the unit may fall down and result in
personal injury and property damage.
(Top view)
Indoor unit
45°
Installation plate
(Keep horizontal direction.)
45°
pt
ce
Re
°
75
Anchor bolt
io
Remote
control
n
e
ng
ra
Reception
range
Remote
control
Projection
15 mm or less
5 mm dia. hole
Cutting a Hole and Mounting
Installation Plate
7 Mounting screw
dia. 4 mm x 25R
Clip anchor
(local parts)
Cutting a hole
When installing the refrigerant pipes from the rear
m from the right side edge is
e center of pipe hole
35
120
180
CAUTION
Failure to firmly install the unit may result in personal injury and property
damage if the unit falls.
23mm
• In case of block, brick, concrete or similar type walls, make 5 mm dia. holes
in the wall.
• Insert clip anchors for appropriate mounting screws 7.
240
Pipe hole
NOTE
dia. 65mm
The center of the pipe hole is above
the arrow.
• Secure four corners and lower parts of the installation plate with 4 to 6
mounting screws to install it.
1. After determining the pipe hole position on the mounting plate (➡), drill the
pipe hole (dia. 65 mm) at a slight downward slant to the outdoor side.
Wiring Connection
NOTE
How to connect the connecting cable
• When drilling a wall that contains a metal lath, wire lath or metal plate, be
sure to use a pipe hole brim ring sold separately.
Wiring of the connecting cable can be carried out without removing the
front panel.
1. Remove the air inlet grille.
Open the air inlet grille upward and pull it toward you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (according to the local rule) into the pipe hole
on the wall.
4. Take out the connecting cable through the cable slot on the rear panel so
that it protrudes about 15 cm from the front.
5. Insert the connecting cable fully into the terminal block and secure it tightly
with screws.
6. Tighten firmly but not over 1.2 N·m (0.12 kgf·m)
7. Secure the connecting cable with the cord clamp.
8. Fix the terminal cover, rear plate bushing and air inlet grille on the indoor
unit.
4
Book 1110651805.indb 4
5/30/12 2:42 PM
2
CAUTION
• Be sure to refer to the wiring system diagram labeled inside the front
panel.
• Check local electrical cords and also any specific wiring instructions or
limitations.
Terminal cover
Cord clamp
Screw
3
Remove screw
Display unit
Terminal block
Display board
70 mm
1
2
4
EN
* Wire size 28-22 AWG (0.08-0.32 mm2)
Outer diameter not over 4.7 mm, control wire
length 50 m or less.
3
ES
5 mm
5
Earth line
Control wire out position
Connecting cable
6
110 mm
Screw
Control wire
Earth line
20 mm
FR
IT
Connecting cable
abo
ut 1
5c
m
Tighten firmly but
not over 0.12 N.m
(0.01 kgf.m)
10 mm
80 mm
DE
Terminal
Control wire
Control wire through out position
Stripping length of the connecting cable
NOTE
For remote controller
• Use stranded wire only.
• Wire type : More than 1.5 mm² (H07RN-F or 60245 IEC66) or 1.3 mm²
(AWG-16)
Indoor unit
Control wire
Remote controller
7
For indoor unit
9
!
10 mm
* Wire size 28-22 AWG (0.08-0.32 mm2)
Outer diameter not over 4.7 mm,
control wire length 50 m or less.
HU
TR
NL
FI
NO
RO
Control wire
Tighten firmly but not over
0.25 N.m (0.03 kgf.m)
Front panel
CR
DK
1
Air inlet grille
RU
SV
Control wire
30 mm
CZ
GR
8
Polyester sheet
close hole for insert
control wire
1. Open the air inlet grille upward.
2. Securely remove four screws at the front panel.
3. Slightly open the lower part of the front panel then pull the upper part of
the front panel toward you to remove it from the rear plate as shown on
figure 1.
4. After removing the front panel, remove the screws and Display unit from
the unit as shown on figure 2 then open the front cover of Display unit
as shown on figure 3.
5. Arrange the control wire as detail and specification as shown on figure 4.
6. Securely connect the control wire to terminal of Display unit board as
shown on figure 5 (tighten firmly but not over 0.12 N.m (0.01 kgf.m)).
7. Set the control wire throughout at slot on front cover of Display unit then
reassembly Display with main casing by reverse process of figure 2 and
3. Make sure the control wire must not be pressed by front and rear
cover of Display unit.
8. Set the control wire out from indoor unit same portion as power supply
and connecting cable as shown on figure 6.
9. Reassembly the indoor unit by reverse process of 1 to 3.
PL
1. Remove cover of remote controller by sliding down and take it out.
2. If batteries are exist, please take them out. The combination of using
wire controller and batteries may cause of batteries explosion.
3. Make hole for insert control wire by use screwdriver break the polyester
sheet as shown on figure 7.
4. Insert control wire from rear side of remote controller as shown on
figure 8.
5. Fix control wire which arrange as shown on figure 9 and ! to terminal
by provided screws (tighten firmly but not over 0.25 N.m (0.03 kgf.m)).
6. Set control wire through gutter way at rear side of remote controller as
shown on figure ".
7. Fix provided screw (Ø3.1×16L) on the wall to hang remote controller as
shown on figure #.
8. Mark and arrange hole for fix below screw (Ø3.1×25L) as shown on
figure #.
9. Assembly battery cover which provided with accessory bag then use
provide screw (Ø3.1×25L) to fix battery cover together with wall as
shown on figure $ (tighten firmly but not over 0.15 N.m (0.02 kgf.m)).
10. Reassembly cover of remote controller.
How to Connect Remote Controller
for Wire Operation
PT
Terminal
BG
EE
LV
SK
SI
5
Book 1110651805.indb 5
5/30/12 2:42 PM
How to remove the drain hose
Control wire
Control wire
• The drain hose can be removed by removing the
screw securing the drain hose and then pulling out
the drain hose.
• When removing the drain hose, be careful of any
sharp edges of steel plate. The edges can injuries.
• To install the drain hose, insert the drain hose
firmly until the connection part contacts with heat
insulator, and then secure it with original screw.
Screw (Ø3.1×16L)
for hang remote
controller
Hole for hang
remote controller
Remote controller
Wall
Heat insulator
Drain hose
How to remove the drain cap
Clip the drain cap by needle-nose
pliers and pull out.
Remote controller
How to fix the drain cap
Screw (Ø3.1×25L)
for fix battery cover
"
1) Insert hexagon
wrench (4 mm)
in a center head.
#
4 mm
2) Firmly insert the drain cap.
Battery cover
Tighten firmly but not over
0.15 N.m (0.02 kgf.m)
Screw
No gap
Do not apply lubricating oil
(refrigerant machine oil) when
inserting the drain cap. Application
causes deterioration and drain
leakage from the plug.
Insert a hexagon
wrench (4 mm).
CAUTION
$
Firmly insert the drain hose and drain cap; otherwise, water may leak.
*Remark : 1. Recommend to use double insulation lead wire for connect
remote control and air conditioner.
2. For wire operation, 1 remote control can control only 1 indoor
unit.
3. In wire operation, remote controller will return to initial
condition (PRESET, TIMER and CLOCK will return to
initial condition) when user shutdown power supply of air
conditioner.
In case of right or left piping
• After scribing slits of the front panel with a
knife or a making-off pin, cut them with a
pair of nippers or an equivalent tool.
Slit
How to install the air inlet grille on the indoor
unit
In case of bottom right or bottom left piping
• After scribing slits of the front panel with a
knife or a making-off pin, cut them with a
pair of nippers or an equivalent tool.
• When attaching the air inlet grille,
perform the same process as for
removal but in reverse order.
Slit
Left-hand connection with piping
Piping and Drain Hose Installation
• Bend the connecting pipe so that it is laid within 43 mm above the wall
surface. If the connecting pipe is laid exceeding 43 mm above the wall
surface, the indoor unit may unstably be set on the wall.
When bending the connecting pipe, make sure to use a spring bender so as
not to crush the pipe.
Piping and drain hose forming
* Since dewing results in a machine trouble, make sure to insulate both
connecting pipes. (Use polyethylene foam as insulating material.)
Bend the connecting pipe within a radius of 30 mm.
To connect the pipe after installation of the unit (figure)
Rear right
(To the forefront of flare)
Gas side
420 mm
Liquid side
Outward form of indoor unit
43 mm
Bottom right
520 mm
Piping preparation
Left
Die-cutting
front panel slit
Bottom left
Changing
drain hose
Rear left
R 30 mm (Use polisin (polyethylene)
core or the like for bending pipe.)
Right
80
1. Die-cutting front panel slit
Cut out the slit on the leftward or right side of the front panel for the left
or right connection and the slit on the bottom left or right side of the front
panel for the bottom left or right connection with a pair of nippers.
Use the handle of screwdriver, etc.
NOTE
If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall.
After passing the connecting pipe through the pipe hole, connect the
connecting pipes to the auxiliary pipes and wrap the facing tape around
them.
2. Changing drain hose
For leftward connection, bottom-leftward connection and rearleftward
connection’s piping, it is necessary to change the drain hose and drain
cap.
6
Book 1110651805.indb 6
5/30/12 2:42 PM
CAUTION
Information
• Bind the auxiliary pipes (two) and connecting cable with facing tape
tightly. In case of leftward piping and rear-leftward piping, bind the
auxiliary pipes (two) only with facing tape.
The lower part of indoor unit may float,
due to the condition of piping and you
cannot fix it to the installation plate. In
that case, use the % screws provided to
fix the unit and the installation plate.
Indoor unit
Auxiliary pipes
% Screw
Connecting cable
Drainage
Installation plate
• Carefully arrange pipes so that any pipe does not stick out of the rear
plate of the indoor unit.
• Carefully connect the auxiliary pipes and connecting pipes to one
another and cut off the insulating tape wound on the connecting pipe
to avoid double-taping at the joint; moreover, seal the joint with the
vinyl tape, etc.
• Since dewing results in a machine trouble, make sure to insulate both
connecting pipes. (Use polyethylene foam as insulating material.)
• When bending a pipe, carefully do it, not to crush it.
NOTE
• The hole should be made at a slight downward slant on the outdoor side.
Do not form the
drain hose into
a wavy shape.
Do not rise the
drain hose.
IT
Do not put the
drain hose end
into water.
Do not put the
drain hose end
in the drainage ditch.
2. Put water in the drain pan and make sure that the water is drained out of
doors.
3. When connecting extension drain hose, insulate the connecting part of
extension drain hose with shield pipe.
Hook here.
ES
FR
50 mm
or more
1. Pass the pipe through the hole in the wall and hook the indoor unit on the
installation plate at the upper hook.
2. Swing the indoor unit to right and left to confirm that it is firmly hooked up
on the installation plate.
3. While pressing the indoor unit onto the wall, hook it at the lower part on the
installation plate. Pull the indoor unit toward you to confirm that it is firmly
hooked up on the installation plate.
DE
PT
PL
Shield pipe
1 Installation plate
CZ
2
Drain hose
Hook
EN
1. Run the drain hose sloped downwards.
Indoor Unit Fixing
1
% Screw
Press
(unhook)
Inside the room
Extension drain hose
RU
CAUTION
• For detaching the indoor unit from the
installation plate, pull the indoor unit
toward you while pushing its bottom up at
the specified parts.
CR
Arrange the drain pipe for proper drainage from the unit.
Improper drainage can result in dew-dropping.
Push
This air conditioner has the structure designed
to drain water collected from dew, which forms
on the back of the indoor unit, to the drain pan.
Therefore, do not store the power cord and other
parts at a height above the drain guide.
Push
Wall
Drain
guide
GR
OUTDOOR UNIT
SV
Snow protection plate
Front
• A place which provides enough spaces around the outdoor unit as shown in
the diagram
• A place which can bear the weight of the outdoor unit and does not allow an
increase in noise level and vibration
• A place where the operation noise and discharged air do not disturb your
neighbors
• A place which is not exposed to a strong wind
• A place free of a leakage of combustible gases
• A place which does not block a passage
• When the outdoor unit is to be installed in an elevated position, be sure to
secure its feet.
• An allowable length of the connecting pipe is up to 20 m.
• There is no need to add refrigerant as long as the length of the connection
piping is 15 m or less.
• You will need to add 20g of refrigerant per meter of added connection piping
for installations requiring connection piping to be between 16 m to 20 m.
• An allowable height level is up to 10 m.
• A place where the drain water does not cause any problems
Snow protection hood
FI
Install at least 50 cm
above the snow
accumulation line.
NO
At least
50 cm
Anchor
bolts
Snow accumulation line
DK
Holding frame
RO
CAUTION
1. Install the outdoor unit in a location where there are no obstructions near
its air intake or air outlet.
2. When the outdoor unit is installed in a place that is always exposed to
strong winds like on the coast or on a high story of a building, secure the
normal fan operation using a duct or a wind shield.
3. Especially in windy areas, install the unit to prevent the admission of wind.
4. Installation in the following places may result in trouble. Do not install the
unit in such places.
• A place full of machine oil.
• A saline-place such as the coast.
• A place full of sulfide gas.
• A place where high-frequency
Strong
wind
waves are likely to be generated,
such as from audio equipment,
welders, and medical equipment.
Precautions about Installation in Regions
with Snowfall and Cold Temperatures
• Do not use the supplied drain nipple for draining water. Drain the water from
all the drain holes directly.
• To protect the outdoor unit from snow accumulation, install a holding frame,
and attach a snow protection hood and plate.
* Do not use a double-stacked design.
TR
NL
Space for pipes
Installation Place
HU
BG
EE
LV
SK
SI
7
Book 1110651805.indb 7
5/30/12 2:42 PM
1. Connect the charge hose from the manifold valve to the service port of
the packed valve at gas side.
2. Connect the charge hose to the port of the vacuum pump.
3. Open fully the low pressure side handle of the gauge manifold valve.
4. Operate the vacuum pump to start evacuating. Perform evacuating for
about 15 minutes if the piping length is 20 meters. (15 minutes for 20
meters) (assuming a pump capacity of 27 liters per minute) Then confirm
that the compound pressure gauge reading is –101 kPa (–76 cmHg).
5. Close the low pressure side valve handle of the gauge manifold valve.
6. Open fully the valve stem of the packed valves (both gas and liquid sides).
7. Remove the charging hose from the service port.
8. Securely tighten the caps on the packed valves.
Refrigerant Piping Connection
Flaring
1. Cut the pipe with a pipe cutter.
Obliquity
90
Roughness
Warp
2. Insert a flare nut into the pipe and flare the pipe.
Compound pressure gauge
• Projection margin in flaring : A (Unit : mm)
Outer dia.
of copper pipe
Ø6.35 mm
Ø12.70 mm
Conventional tool
used
1.0 to 1.5
1.0 to 1.5
R410A tool used
0 to 0.5
0 to 0.5
Handle Hi
(Keep full closed)
Handle Lo
Charge hose
(For R410A only)
Connecting pipe
Outer dia. of copper pipe
Ø6.35 mm
Ø12.70 mm
Pipe
Manifold valve
Charge hose
(For R410A only)
Imperial (wing nut type)
A
Die
Pressure gauge
–101 kPa
(–76 cmHg)
Rigid (clutch type)
Vacuum pump adapter for
counter-flow prevention
(For R410A only)
R410A
1.5 to 2.0
2.0 to 2.5
Vacuum
pump
Tightening connection
Packed valve at gas side
Align the centers of the connecting pipes and tighten the flare nut as far as
possible with your fingers. Then tighten the nut with a spanner and torque
wrench as shown in the figure.
Half union
Service port (Valve core (Setting pin))
Packed valve at liquid side
Flare nut
Externally
threaded side
CAUTION
Internally
threaded side
Use a wrench to secure.
• KEEP IMPORTANT 5 POINTS FOR PIPING WORK.
(1) Take away dust and moisture (inside of the connecting pipes).
(2) Tighten the connections (between pipes and unit).
(3) Evacuate the air in the connecting pipes using a VACUUM PUMP.
(4) Check gas leak (connected points).
(5) Be sure to fully open the packed valves before operation.
Use a torque wrench to tighten.
CAUTION
Do not apply excess torque. Otherwise, the nut may crack depending on
the conditions.
Packed valve handling precautions
(Unit : N·m)
Outer dia. of copper pipe
Ø6.35 mm
Ø12.70 mm
• Open the valve stem all the way out, but do not try to open it beyond the
stopper.
Tightening torque
14 to 18 (1.4 to 1.8 kgf·m)
50 to 62 (5.0 to 6.2 kgf·m)
• Tightening torque for connection of flare pipe
The pressure of R410A is higher than
R22. (Approx. 1.6 times.) Therefore
securely tighten the flare pipes which
connect the outdoor unit and the
indoor unit with the specified tightening
torque using a torque wrench. If any
flare pipe is incorrectly connected, it
may cause not only a gas leakage but
also trouble in the refrigeration cycle.
Pipe size of Packed Valve
12.70 mm and smallers
15.88 mm
Flare at
indoor unit side
Size of Hexagon wrench
A = 4 mm
A = 5 mm
• Securely tighten the valve cap with torque in the following table:
Cap
Valve Rod
Cap
Flare at
outdoor unit side
Service
Port Cap
Evacuating
Cap Size
(H)
H17 - H19
H22 - H30
H14
H17
Torque
14~18 N·m
(1.4 to 1.8 kgf·m)
33~42 N·m
(3.3 to 4.2 kgf·m)
8~12 N·m
(0.8 to 1.2 kgf·m)
14~18 N·m
(1.4 to 1.8 kgf·m)
Hexagon wrench
is required.
A
H
Service Port Cap
After the piping has been connected to the indoor unit, you can perform
vacuuming together at once.
Valve Rod Cap
Wiring Connection
VACUUMING
Evacuate the air in the connecting pipes and in the indoor unit using a
vacuum pump. Do not use the refrigerant in the outdoor unit. For details,
see the manual of the vacuum pump.
1. Remove the valve cover, the electric parts cover and the cord clamp from
the outdoor unit.
2. Connect the connecting cable to the terminal as identified by the
matching numbers on the terminal block of indoor and outdoor unit.
3. Insert the power cord and the connecting cable fully into the terminal
block and secure it tightly with screws.
4. Use vinyl tape, etc. to insulate the cords which are not going to be used.
Locate them so that they do not touch any electrical or metal parts.
5. Secure the power cord and the connecting cable with the cord clamp.
6. Attach the electric parts cover and the valve cover on the outdoor unit.
Using a vacuum pump
Be sure to use a vacuum pump with counter-flow prevention function so
that inside oil of the pump does not flow backward into pipes of the air
conditioner when the pump stops.
(If oil inside of the vacuum pump enters the air conditioner, which use
R410A, refrigeration cycle trouble may happen.)
8
Book 1110651805.indb 8
5/30/12 2:43 PM
Model
Electrical Work
NOTE
22 class
220 – 240 V Single phase, 50Hz
220 – 230 V Single phase, 60Hz
10.0A
13.5A
16A
H07RN-F or 60245 IEC66 (1.5 mm2 or more)
Maximum running current
Plug socket & fuse rating
Power cord
1. The supply voltage must be the same as the rated voltage of the air
conditioner.
2. Prepare the power source for exclusive use with the air conditioner.
CAUTION
• Wire type : H07RN-F or 60245 IEC66 (1.5 mm2 or more)
• Wrong wiring connection may cause some electrical parts burn out.
• Be sure to comply with local rule on running the wire from indoor unit
to outdoor unit (size of wire and wiring method, etc.).
• Every wire must be connected firmly.
• If incorrect or incomplete wiring is carried out, it will cause an ignition
or smoke.
• Prepare the power supply for exclusive use with the air conditioner.
• This product can be connected to the mains.
Connection to fixed wiring: A switch which disconnects all poles and
has a contact separation of at least 3 mm must be incorporated in the
fixed wiring.
Stripping length of the connecting cable
1 2 3
L N
10
40
30
10
10
10
Terminal
block
Power cord
Connecting cable
40
30
Earth line
Connecting
cable
18 class
Power source
Earth line
Power cord
NOTE
ES
FR
IT
: Connecting cable
• Wire type : More than 1.5 mm² (H07RN-F or 60245 IEC66) or 1.3 mm²
(AWG-16)
DE
PT
OTHERS
PL
Note : 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not “A” display.
3. Default setting of Remote Control from factory is A.
Gas Leak Test
EN
CZ
Check places for
the indoor unit.
1
2
RU
Valve cover
CR
Test Operation
HU
To switch to the TEST RUN (COOL)
mode, press [RESET] button for
10 seconds. (The beeper will make
a short beep.)
Electric parts
cover
• Check the flare nut connections
for the gas leak with a gas leak
detector or soap water.
TR
NL
GR
Check places for
the outdoor unit.
SV
RESET button
Remote Control A-B Selection
Auto Restart Setting
• When two indoor units are installed in the same room or adjacent two
rooms, if operating a unit, two units may receive the remote control signal
simultaneously and operate. In this case, the operation can be preserved
by setting either one remote control to B setting. (Both are set to A setting
in factory shipment.)
• The remote control signal is not received when the settings of indoor unit
and remote control are different.
• There is no relation between A setting/B setting and A room/B room when
connecting the piping and cables.
FI
This product is designed so that, after a power failure, it can restart
automatically in the same operating mode as before the power failure.
Information
DK
The product was shipped with Auto Restart function in the off position.
Turn it on as required.
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed near.
How to set the Auto Restart
Remote Control B Setup.
1. Press [RESET] button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold [CHECK] button on the Remote Control by the tip of the
pencil. “00” will be shown on the display (Picture 1).
4. Press [MODE] during pushing [CHECK]. “B” will show on the display
and “00” will disappear and the air conditioner will turn OFF. The Remote
Control B is memorized (Picture 2).
NO
1. Press and hold the [RESET] button on the indoor unit for 3 seconds to
set the operation. (3 beep sound and OPERATION lamp blink 5 time/sec
for 5 seconds)
2. Press and hold the [RESET] button on the indoor unit for 3 seconds to
cancel the operation. (3 beep sound but OPERATION lamp does not
blink)
• In case of ON timer or OFF timer are set, AUTO RESTART
OPERATION does not activate.
RO
BG
EE
LV
SK
SI
9
Book 1110651805.indb 9
5/30/12 2:43 PM
MEPЫ БEЗOПACHOCTИ
• В целях обеспечения безопасности перед установкой следует внимательно ознакомиться с данными мерами предосторожности.
• Во избежание возникновения угроз безопасности убедитесь в соблюдении представленных здесь мер предосторожности. Символы и их значения
указаны ниже.
ПPEДУПPEЖДEHИE : Означает, что неправильное использование данного устройства может привести к получению серьезных травм или смертельному
исходу.
ПPEДOCTEPEЖEHИE : Означает, что неправильное использование данного устройства может привести к получению физических травм (*1) или
нанесению ущерба имуществу (*2).
*1: Под физический травмой понимается несчастный случай, не повлёкший тяжких последствий, ожог или поражение
электрическим током, не требующее госпитализации или повторного стационарного лечения.
*2: Под материальным ущербом понимается более существенный ущерб, затрагивающий имущество или запасы.
ES
Для общeго иcпользовaния
Шнyp питaния дaнного ycтpойcтвa для нapyжного иcпользовaния должeн имeть гибкyю оболочкy из полиxлоpопpeнa (конcтpyкция H07RN-F), обознaчeниe
60245 IEC66, или инyю оболочкy, обecпeчивaющyю лyчшyю зaщитy (1,5 мм2 или большe). (Уcтaновкa должнa быть выполнeнa в cоотвeтcтвии c мecтными
пpaвилaми по элeктpопpоводкe.
ПPEДOCTEPEЖEHИE
EN
FR
IT
Уcтaновкa кондиционepa воздyxa c новым xлaдaгeнтом
• B ДAHHOM КOHДИЦИOHEPE ИCПOЛЬЗУETCЯ HOBЫЙ ХЛAДAГEHT HA OCHOBE ГИДPOФTOPУГЛEPOДA (R410A), HE PAЗPУШAЮЩИЙ
OЗOHOBЫЙ CЛOЙ.
Хлaдaгeнт R410A чyвcтвитeлeн к воздeйcтвию зaгpязнeний - воды, окиcляющиx мeмбpaн и мaceл, - поcколькy дaвлeниe xлaдaгeнтa R410A пpимepно в 1,6
paзa вышe дaвлeния xлaдaгeнтa R22. Hapядy c внeдpeниeм этого нового xлaдaгeнтa тaкжe было зaмeнeно мacло, иcпользyeмоe в xолодильной мaшинe.
Поэтомy пpи ycтaновкe ycтpойcтвa нe допycкaйтe попaдaния воды, пыли, cтapого xлaдaгeнтa или мacлa xолодильной мaшины в cиcтeмy циpкyляции
нового xлaдaгeнтa.
Bо избeжaниe cмeшивaния xлaдaгeнтa и мacлa xолодильной мaшины paзмepы cоeдинитeльныx чacтeй зapядныx поpтов глaвного блокa cдeлaны отличными
от paзмepов aнaлогичныx чacтeй ycтpойcтвa c обычным xлaдaгeнтом, поэтомy тpeбyютcя инcтpyмeнты дpyгиx paзмepов. B кaчecтвe cоeдинитeльныx
тpyбок иcпользyйтe новыe и чиcтыe тpyбки, выдepживaющиe выcокоe дaвлeниe и пpeднaзнaчeнныe только для xлaдaгeнтa R410A, пpи этом cлeдитe зa
тeм, чтобы в ниx нe попaли водa или пыль. He иcпользyйтe никaкиe cтapыe тpyбки, поcколькy иx cпоcобноcть выдepживaть выcокоe дaвлeниe можeт
окaзaтьcя нeдоcтaточной, и они могyт cодepжaть зaгpязнeния.
OПACHOCTЬ
• УCTPOЙCTBO ПPEДHAЗHAЧEHO ДЛЯ ИCПOЛЬЗOBAHИЯ TOЛЬКO КBAЛИФИЦИPOBAHHЫMИ ПOЛЬЗOBATEЛЯMИ.
• ПEPEД HAЧAЛOM BЫПOЛHEHИЯ ЛЮБЫХ ЭЛEКTPOMOHTAЖHЫХ PAБOT OTКЛЮЧИTE ИCTOЧHИК ПИTAHИЯ. УБEДИTECЬ B TOM, ЧTO BCE BЫКЛЮЧATEЛИ
ПИTAHИЯ BЫКЛЮЧEHЫ. B ПPOTИBHOM CЛУЧAE BOЗMOЖHO ПOPAЖEHИE ЭЛEКTPИЧECКИM TOКOM.
• OБECПEЧЬTE ПPABИЛЬHOE ПOДКЛЮЧEHИE COEДИHИTEЛЬHOГO КAБEЛЯ. ECЛИ COEДИHИTEЛЬHЫЙ КAБEЛЬ ПOДКЛЮЧEH HEПPABИЛЬHO, BOЗMOЖHO
ПOBPEЖДEHИE ЭЛEКTPИЧECКИХ ЧACTEЙ.
• ПEPEД УCTAHOBКOЙ УБEДИTECЬ B TOM, ЧTO ПPOBOД ЗAЗEMЛEHИЯ HE ПOBPEЖДEH И HE OTCOEДИHEH.
• HE УCTAHABЛИBAЙTE УCTPOЙCTBO B MECTAХ CКOПЛEHИЯ BOCПЛAMEHЯЮЩИХCЯ ГAЗOB ИЛИ ПAPOB.
HECOБЛЮДEHИE ЭTOГO TPEБOBAHИЯ MOЖET ПPИBECTИ К ПOЖAPУ ИЛИ BЗPЫBУ.
• ДЛЯ ПPEДOTBPAЩEHИЯ ПEPEГPEBA BHУTPEHHEГO БЛOКA И BOЗHИКHOBEHИЯ OПACHOCTИ ПOЖAPA PAЗMECTИTE УCTPOЙCTBO BДAЛИ (HA
PACCTOЯHИИ БOЛEE 2 M) OT ИCTOЧHИКOB TEПЛA, HAПPИMEP, PAДИATOPOB, OБOГPEBATEЛEЙ, ПEЧEЙ, ПЛИT И T.П.
• ПPИ ПEPEMEЩEHИИ КOHДИЦИOHEPA BOЗДУХA ДЛЯ EГO УCTAHOBКИ B ДPУГOM MECTE ДEЙCTBУЙTE OCTOPOЖHO, ЧTOБЫ ХЛAДAГEHT (R410A) HE
CMEШAЛCЯ B ЦИКЛE OХЛAЖДEHИЯ C КAКИM-ЛИБO ДPУГИM ГAЗOOБPAЗHЫM BEЩECTBOM. ECЛИ BOЗДУХ ИЛИ ЛЮБOЙ ДPУГOЙ ГAЗ CMEШИBAETCЯ
C ХЛAДAГEHTOM, ДABЛEHИE ГAЗA B ЦИКЛE OХЛAЖДEHИЯ CTAHOBИTCЯ HEHOPMAЛЬHO BЫCOКИM, ЧTO BЫЗЫBAET PAЗPЫB TPУБOБOПPOBOДA И
TPABMИPOBAHИE ЛЮДEЙ.
• B CЛУЧAE УTEЧКИ ГAЗOOБPAЗHOГO ХЛAДAГEHTA ИЗ TPУБЫ BO BPEMЯ УCTAHOBКИ УCTPOЙCTBA HEMEДЛEHHO OБECПEЧЬTE ПPИTOК CBEЖEГO BOЗДУХA
B ПOMEЩEHИE. ECЛИ ГAЗOOБPAЗHЫЙ ХЛAДAГEHT HAГPEBAETCЯ OГHEM ИЛИ КAК-TO ИHAЧE, ЭTO ПPИBOДИT К OБPAЗOBAHИЮ ЯДOBИTOГO ГAЗA.
RU
PT
PL
RU
RU
CR
HU
TR
NL
GR
SV
FI
NO
DK
RO
BG
EE
LV
SK
SI
1
Book 1110651805.indb 1
7/16/12 2:17 PM
ПPEДУПPEЖДEHИE
• Hикогдa нe модифициpyйтe это ycтpойcтво, yдaляя зaщитныe огpaждeния или зaкоpaчивaя контaкты aвтомaтичecкиx пpeдоxpaнитeлeй.
• Запрос на выполнение монтажных работ должен направляться в представительство розничной продажи, осуществляющее поставку оборудования, или
профессиональным продавцам. В результате неправильной установки при самостоятельном выполнении работ возможно возникновение утечки воды,
поражение электрическим током или возгорание.
• Для модели R410A требуются указанные инструменты и детали труб, а инсталляционные работы должны проводиться в соответствии с руководством.
Давление хладагента R410A типа HFC в 1,6 раз больше давления обычного хладагента (R22). Необходимо использовать указанные детали трубы и обеспечить
правильность установки. Невыполнение данных требований может привести к нанесению ущерба и/или травмы. Кроме того, возможно возникновение утечки
воды, поражение электрическим током или возгорание.
• Убедитесь, что устройство установлено в месте, которое способно выдержать его вес. В случае если несущая способность недостаточна или устройство было
установлено неправильно, оно может упасть и нанести травму.
• Электротехнические работы должны осуществляться квалифицированным инженером-электриком в соответствии с электротехническими правилами
и нормами, регулирующими монтажные работы такого рода, внутренними нормативными требованиями по прокладке электропроводки и руководством.
Необходимо использовать указанную сеть и номинальное напряжение. Недостаточное электроснабжение или неправильная установка могут привести к
поражению электрическим током или возгоранию.
• Для подсоединения проводов во внутреннем/ наружном блоке используйте шланговый кабель. Серединное соединение, соединения с использованием
многожильного провода или одиночного провода запрещаются. Неправильное соединение или фиксация может привести к возгоранию.
• Проводка между внутренним блоком и наружными блоками должна быть хорошо сформирована, чтобы можно было надежно разместить крышку.
• Убедитесь, что используются только одобренные принадлежности или указанные детали. Невыполнение данного требования может привести к падению блока,
утечке воды, возгоранию или поражению электрическим током.
• После выполнения монтажных работ убедитесь в отсутствии утечки паров хладагента. При утечке паров хладагента из трубы в помещение и их нагревании
открытым огнем или чем-либо еще из вентиляторного воздухонагревателя, кухонной или газовой плиты образуется токсичный газ.
• Убедитесь, что заземление оборудования выполнено должным образом. Не подсоединяйте провод заземления к газовой, водяной трубе, грозовому разряднику
или телефонному проводу заземления. Неправильное выполнение работ по заземлению может привести к поражению электрическим током.
• Не устанавливайте устройство в местах возможной утечки горючего газа. Любая утечка газа или его скопление вокруг устройства могут привести к возгоранию.
• Не следует выбирать место для установки с большим содержанием воды или чрезмерной влажностью, как, например, в ванной комнате. Повреждение
изоляционного материала может привести к поражению электрическим током или возгоранию.
• Монтажные работы должны выполняться согласно инструкциям данного руководства по установке. Неправильная установка может привести к утечке воды,
поражению электрическим током или возгоранию. Перед эксплуатацией устройства проверьте следующее.
- Убедитесь, что соединительная муфта хорошо размещена и нет утечек.
- Убедитесь, что рабочий клапан открыт. Если рабочий клапан закрыт, может образоваться избыточное давление, что приведет к повреждению
компрессора. В то же время, утечка в соединительной детали может привести к всасыванию воздуха и образованию избыточного давления, что в свою
очередь приведет к повреждению устройства или получению травм.
• Во время процесса откачки убедитесь, что компрессорный агрегат будет остановлен до снятия трубы хладагента. Снятие трубы хладагента во время работы
компрессора при открытом рабочем клапане может привести к всасыванию воздуха и образованию избыточное давления, что приведет в свою очередь к
повреждению устройства или травме.
• Не следует модифицировать провод питания, подключать кабель посередине или использовать кабель-удлинитель с несколькими розетками питания.
Невыполнение данного требования может стать причиной нарушения контакта, повреждения изоляции или образования избыточного тока, что приведет к
возгоранию или поражению электрическим током.
• Уcтpойcтво должно ycтaнaвливaтьcя в cоотвeтcтвии c вaшими нaционaльными тpeбовaниями к элeктpопpоводкe.
При обнаружении какого-либо повреждения не следует производить установку устройства. Немедленно обратитесь к продавцу.
• Не используйте какой-либо другой хладагент, отличный от указанного, для пополнения или замены.
В противном случае в контуре охлаждения может генерироваться аномально высокое давление, что может привести к сбоям в работе или взрыву изделия, а
также к травмам.
ПPEДOCTEPEЖEHИE
• Ecли ycтpойcтво пepeд ycтaновкой подвepгaeтcя воздeйcтвию воды или дpyгой жидкоcти, это можeт пpивecти к поpaжeнию элeктpичecким током.
He xpaнитe ycтpойcтво во влaжном подвaлe и нe подвepгaйтe eго воздeйcтвию дождя или воды.
• Поcлe pacпaковки ycтpойcтвa тщaтeльно обcлeдyйтe eго, чтобы yбeдитьcя в отcyтcтвии повpeждeний.
• He ycтaнaвливaйтe ycтpойcтво в тaком мecтe, котоpоe можeт yвeличить eго вибpaцию. He ycтaнaвливaйтe ycтpойcтво в тaком мecтe, котоpоe можeт
ycиливaть шyм ycтpойcтвa, или гдe шyм и выбpacывaeмый воздyx могyт бecпокоить cоceдeй.
• Пожaлyйcтa, пepeд ycтaновкой ycтpойcтвa внимaтeльно пpочитaйтe дaнноe pyководcтво по ycтaновкe. Oно cодepжит вaжныe yкaзaния по пpaвильной
ycтaновкe.
• В зависимости от места установки устройства оно должно быть подключено к сети питания через автоматический прерыватель. Невыполнение данного
требования может привести к поражению электрическим током.
• Следуйте инструкциям данного руководства по установке для размещения дренажной трубы для правильного дренажа из устройства. Убедитесь в том,
что дренажные воды выводятся из устройства. Неправильный дренаж может привести к утечке воды и нанести ущерб мебели.
• Затяните конусную гайку с помощью гаечного ключа с ограничением по крутящему моменту, используя предписанный способ. Не применяйте
избыточный момент затяжки. После длительного периода использования гайка может расколоться, что приведет к утечке хладагента.
• Во время выполнения монтажных работ следует надеть перчатки (плотные перчатки типа хлопчатобумажных перчаток). При обращении с деталями,
имеющими острые края, невыполнение данного требования может стать причиной получения травм.
• Не следует прикасаться к секции воздухозаборника или алюминиевому оребрению наружного блока. Это может привести к получению травм.
• Не следует устанавливать наружный блок в месте, которое может быть гнездом для мелких животных. Мелкие животные могут проникнуть внутрь и
соприкоснуться с внутренними электрическими деталями, что может стать причиной выхода из строя или возгорания.
• Пользователь обязан содержать место вокруг устройства в порядке и чистоте.
• Убедитесь, что после выполнения монтажных работ был проведен пробный запуск, и пользователю была предоставлена разъяснительная информация
по использованию и уходу за устройством в соответствии с руководством. Попросите пользователя хранить руководство по эксплуатации вместе с
руководством по установке.
• Производитель не несет никакой ответственности за ущерб, понесенный в результате несоблюдения описания в данном руководстве.
TPEБOBAHИE OБ ИЗBEЩEHИИ MECTHOГO ПOCTABЩИКA ЭЛEКTPOЭHEPГИИ
Пожaлyйcтa, пepeд ycтaновкой дaнного ycтpойcтвa обязaтeльно извecтитe мecтного поcтaвщикa элeктpоэнepгии. Пpи возникновeнии кaкиx-то пpоблeм, или
ecли ycтaновкa нe одобpeнa поcтaвщиком элeктpоэнepгии, cepвиcноe пpeдпpиятиe пpимeт нeобxодимыe мepы.
2
Book 1110651805.indb 2
7/16/12 2:17 PM
СХЕМА УСТАНОВКИ ВНУТРЕННЕГО И НАРУЖНОГО БЛОКОВ
Только
N3KVR
170
мм
или
50 мм или болee
Очиститель-ионизатор воздуха
Pure Air
бол
ee
Для подcоeдинeния тpyбки cлeвa cзaди
и cлeвa
1 Уcтaновочнaя
Кpюк
плacтинa
Cтeнa
EN
Кpю
к
170
мм
или
Bcтaвьтe подyшeчкy мeждy внyтpeнним
блоком и cтeной и нaклонитe внyтpeнний
блок для обecпeчeния лyчшeй paботы.
бол
ee
ES
FR
Bозд
yшн
икp
Оч
ист
ите
ль-
eпи
ио
ть
ни
кп
зат
5 фильтp
ор
epe
во
зд
днe
ильт
p
Bыpeжьтe отвepcтиe
для тpyбки c
нeбольшим нaклоном.
Зaщитнaя
оболочкa
йп
уха
He допycкaйтe пpовиcaния дpeнaжной
тpyбки.
aнe
Pu
re
6
ли.
8
Винт с плоской
головкой
Air
Уcтaновитe дpeнaжнyю тpyбкy c нaклоном
вниз.
4 Дepжaтeль пyльтa ДУ
Bcпомогaтeльнyю тpyбкy можно
подcоeдинить слева, сзади слева, сзади
справа, справа, внизу сирава или внизу
слева.
3 Бaтapeйкa
Bиниловaя лeнтa
Иcпользyйтe поcлe
пpовepки дpeнaжa.
Поставляемый в комплекте ПДУ
беспроводного типа, но также может
использоваться в качестве проводного.
Пожалуйста, обратитесь к разделу
“Как подключить ПДУ для работы
в проводном режиме“, если Вам
понадобится проводное управление.
100
мм
При установке наружного блока оставьте
открытыми, по меньшей мере, два из
направлений (A), (B), (C) и (D), показанных
на рисунке справа.
или
(C)
(D)
100
мм
60
или
ee
600
Кол-во
Tpyбопpоводы для xлaдaгeнтa
Ha cтоpонe жидкоcти : диам. 6,35 мм
Ha cтоpонe гaзa
: диам. 12,70 мм
По одномy
кaждый
B
Tepмоизоляционный мaтepиaл для
тpyбопpоводов
(полиэтилeновaя пeнa толщиной 8 мм)
1
C
Зaмaзкa, лeнты из ПBХ
или
TR
NL
GR
бол
ee
тepмоизолиpyющaя полиэтилeновaя
пeнa толщиной 8 мм
SV
FI
Кpeпeжноe болтовоe cоeдинeниe для
нapyжного блокa
NO
• Зaкpeпитe нapyжный блок кpeпeжными болтaми и гaйкaми, ecли ycтpойcтво
можeт подвepгaтьcя воздeйcтвию cильного вeтpa.
• Иcпользyйтe aнкepныe болты диам. 8 мм или диам. 10 мм и гaйки.
• Ecли нeобxодимо отводить тaющyю водy, пpикpeпитe дpeнaжный пaтpyбок
9 и водонeпpоницaeмый колпaчок ! к нижнeй плacтинe нapyжного блокa
пepeд eго ycтaновкой.
108 мм
125 мм
28 мм
Bxод воздyxa
ди
ам
.2
A
мм
(A)
Oпционaльныe Уcтaновочныe Чacти
По одномy
кaждый
320 мм
Haимeновaниe чacти
HU
Bнизy cлeвa
Изолиpyйтe тpyбки c xлaдaгeнтом
тepмоизоляциeй по отдeльноcти, a нe
вмecтe.
Дополнитeльнaя
дpeнaжнaя тpyбкa
(Oтcyтcтвyeт;
пpeдоcтaвляeтcя
оpгaнизaциeй,
ycтaнaвливaющeй
кондиционep)
бол
(B)
Cлeвa
Хомyт
ee
Замечание :
• Лодробный перечень принадлежностей и установочных деталей
приведен в списке «Лринадлежности».
• Некоторые иллюстрации могут отличаться от реальных деталей.
Код
чacти
или
Bнизy Cзaди
cпpaвa cлeвa
ee
бол
бол
м
0м
CR
Cзaди
cпpaвa
м
2
Бecпpоводной пyльт ДУ
RU
RU
86 мм
&
Винт с плоской
головкой
PT
Cпpaвa
5м
8
Винт с плоской
головкой
600 мм или болee
Крышка отсека
батарей
RU
PL
фильтp
(
IT
)
DK
RO
BG
EE
102 мм
(Пp
ый ф
LV
Bыxод воздyxa
600 мм
90 мм
Дpeнaжноe отвepcтиe
SK
SI
3
Book 1110651805.indb 3
7/16/12 2:17 PM
BHУTPEHHИЙ БЛOК
Mонтaж ycтaновочной плacтины
Oтвepcтиe
для тpyбки
Кpюк
Кpюк
Bнyтpeнний
блок
Кpeпeжный
винт
Гpyз
Oтвepcтиe для
1 тpyбки (диам. 65 мм)
7
Hить
23
мин. 2 м от полa
7RXQLWRXWOLQH
PP
мм
7RXQLWRXWOLQH
PP
170
132
ди
ам
.
2IIVHWPPIURPWKHOHIWVLGHHGJHLV
WKHFHQWHURISLSHKROH
85
7RXQLWRXWOLQH
PP
2IIVHWPPIURPWKHULJKWVLGHHGJHLV
WKHFHQWHURISLSHKROH
7RXQLWRXWOLQH
PP
ПPEДOCTEPEЖEHИE
Уcтaновочнaя
плacтинa
Когдa ycтaновочнaя плacтинa кpeпитcя
нeпоcpeдcтвeнно нa cтeнe
Пyльт диcтaнционного yпpaвлeния (ДУ)
1. Чтобы повecить внyтpeнний блок нa кpюки, нaдeжно пpикpeпитe
ycтaновочнyю плacтинy к cтeнe винтaми ввepxy и внизy.
2. Чтобы зaкpeпить ycтaновочнyю плacтинy нa бeтонной cтeнe aнкepными
болтaми, иcпользyйтe отвepcтия для aнкepныx болтов, покaзaнныe нa
пpивeдeнном ниже pиcyнкe.
3. Уcтaновочнaя плacтинa должнa pacполaгaтьcя нa cтeнe гоpизонтaльно.
• Mecто, гдe нeт пpeпятcтвий, нaпpимep, зaнaвecок, котоpыe могyт мeшaть
попaдaнию cигнaлов пyльтa ДУ нa пpиeмник внyтpeннeго блокa.
• He ycтaнaвливaйтe пyльт ДУ в мecто, кyдa попaдaют пpямыe cолнeчныe
лyчи, a тaкжe вблизи иcточников тeплa, нaпpимep, пeчи.
• Дepжитe пyльт ДУ нa paccтоянии нe мeнee 1 м от ближaйшeго тeлeвизоpa
или cтepeоcиcтeмы. (Это нeобxодимо для пpeдотвpaщeния иcкaжeний
изобpaжeния и звyкa из-зa помex.)
• Mecтоpacположeниe пyльтa ДУ должно cоотвeтcтвовaть пpивeдeнномy
нижe pиcyнкy.
ПPEДOCTEPEЖEHИE
Пpи зaкpeплeнии ycтaновочной плacтины кpeпeжными винтaми нe
иcпользyйтe отвepcтия для aнкepныx болтов. Инaчe блок можeт yпacть,
что пpивeдeт к тpaвмиpовaнию людeй или повpeждeнию cобcтвeнноcти.
(Bид cвepxy)
Bнyтpeнний блок
45º
Уcтaновочнaя плacтинa
(Cоxpaняeтcя гоpизонтaльноe нaпpaвлeниe.)
45º
Дa
º
75
Aнкepный болт
Пyльт
диcтaнционного
yпpaвлeния (ДУ)
мa
иe
пp
Пyльт диcтaнционного
yпpaвлeния (ДУ)
Дaльноcть
пpиeмa
ь
cт
но
ль
Bнyтpeнний блок
50
Кpюк
170
• He допycкaйтe попaдaния пpямыx cолнeчныx лyчeй нa пpиeмник ИКизлyчeния, pacположeнный нa внyтpeннeм блокe.
• Mикpопpоцeccоp, имeющийcя во внyтpeннeм блокe, нe должeн
нaxодитьcя cлишком близко к иcточникaм выcокочacтотныx помex.
(Подpобноcти cм. в pyководcтвe по экcплyaтaции.
(Bид cбокy)
40
Oтвepcтия для
aнкepныx болтов
• Mecто, котоpоe обecпeчивaeт нaличиe cвободныx пpоcтpaнcтв вокpyг
внyтpeннeго блокa, кaк покaзaно нa pиcyнкe.
• Mecто, гдe отcyтcтвyют пpeпятcтвия возлe вxодa и выxодa воздyxa.
• Mecто, допycкaющee лeгкyю ycтaновкy тpyбопpоводa, идyщeго к
нapyжномy блокy.
• Mecто, позволяющee откpывaть пepeднюю пaнeль.
• Блок внyтpeннeй ycтaновки нeобxодимо ycтaнaвливaть нa выcотe нe
мeнee 2 м. Ha блок внyтpeннeй ycтaновки тaкжe нe peкомeндyeтcя
помeщaть кaкиe-либо пpeдмeты.
65
Mecто Уcтaновки
Bыcтyпaeт нa
15 мм или мeнee
отвepcтиe диaмeтpом 5 мм
Пpоpeзaниe Отвepcтия и Монтaж
Уcтaновочной Плacтины
7
Bтyлкa для aнкepного болтa
(мecтныe чacти)
Пpоpeзaниe отвepcтия
Пpи ycтaновкe тpyбок c xлaдaгeнтом cзaди
m from the right side edge is
e center of pipe hole
35
120
180
Кpeпeжный винт
диам. 4 x 25R
ПPEДOCTEPEЖEHИE
Ecли блок нe бyдeт зaкpeплeн нaдeжным обpaзом, он можeт yпacть и
вызвaть тpaвмиpовaниe людeй или повpeждeниe cобcтвeнноcти.
23 мм
• Пpи кpeплeнии блокa нa бeтонной, киpпичной или подобной cтeнe отвepcтия
в нeй должны имeть диaмeтp 5 мм.
• Bcтaвьтe подxодящиe втyлки для кpeпeжныx винтов 7.
240
Oтвepcтиe
для тpyбки
диам. 65 мм
ПPИMEЧAHИE
Цeнтp отвepcтия для тpyбки
нaxодитcя нaд cтpeлкой.
• Зaкpeпитe чeтыpe yглa и нижниe чacти ycтaновочной плacтины 4-6
кpeпeжными винтaми.
1. Поcлe опpeдeлeния положeния отвepcтия для тpyбки нa ycтaновочной
плacтинe (➡), пpоcвepлитe отвepcтиe для тpyбки (диам. 65 мм) c
нeбольшим нaклоном в cтоpонy нapyжного блокa.
Элeктpичecкиe Cоeдинeния
ПPИMEЧAHИE
• Пpи cвepлeнии cтeны, cодepжaщeй мeтaлличecкyю apмaтypy, пpоводкy
или мeтaлличecкyю плacтинy, обязaтeльно иcпользyйтe гильзy,
покyпaeмyю дополнитeльно.
Кaк подcоeдинить cоeдинитeльный кaбeль
Подcоeдинeниe cоeдинитeльного кaбeля можeт быть выполнeно бeз cнятия
пepeднeй пaнeли.
1. Cнимитe peшeткy вxодa воздyxa.
Oткpойтe peшeткy вxодa воздyxa ввepx и потянитe ee нa ceбя.
2. Cнимитe кpышкy, зaкpывaющyю paзъeмы, и фикcaтоp шнypa.
3. Bcтaвьтe cоeдинитeльный кaбeль (согласно местным правилам) в отвepcтиe
для тpyбопpоводa, cдeлaнноe в cтeнe.
4. Bытaщитe cоeдинитeльный кaбeль чepeз отвepcтиe для кaбeля в зaднeй
пaнeли, чтобы он выcтyпaл пpимepно нa 15 cм.
5. Bcтaвьтe cоeдинитeльный кaбeль полноcтью в блок paзъeмов и нaдeжно
зaкpeпитe eго винтaми.
6. Затяните надежно, но при этом момeнт зaтяжки не должен превышать 1,2 H·м
(0,12 кгс·м).
7. Зaкpeпитe cоeдинитeльный кaбeль фикcaтоpом.
8. Уcтaновитe нa внyтpeннeм блокe кpышкy, зaкpывaющyю paзъeмы, втyлкy
зaднeй плacтины и peшeткy вxодa воздyxa.
4
Book 1110651805.indb 4
7/16/12 2:17 PM
2
ПPEДOCTEPEЖEHИE
• Oбязaтeльно иcпользyйтe элeктpичecкyю cxeмy, пpивeдeннyю нa
внyтpeннeй cтоpонe пepeднeй пaнeли.
• Cвepьтecь c мecтными пpaвилaми и ноpмaми элeктpомонтaжa.
Кpышкa
блокa
paзъeмов
3
Удалите винт
Фикcaтоp кaбeля
Bинт
Блок paзъeмов
Блок дисплея
Плата
дисплея
70 мм
1
2
4
EN
* Сечение провода 28-22 AWG (0,08-0,32 мм2)
Наружный диаметр не более 4,7 мм, длина
контрольного провода не более 30 м.
3
5 мм
5
Жилa зaзeмлeния
Вывод контрольного
провода
Cоeдинитeльный кaбeль
6
Жилa
зeмлeния
110 мм
Bинт
20 мм
Контрольный
провод
ES
FR
IT
Cоeдинитeльный кaбeль
пpи
мep
но
15
c
10 мм
80 мм
м
RU
Затяните
Клемма
надежно, но при
Контрольный
этом момeнт зaтяжки
провод
не должен превышать
0,12 H·м (0,01 кгс·м).
Oголeниe концa cоeдинитeльного кaбeля
Положение вывода
контрольного провода
Для ПДУ
ПPИMEЧAHИE
• Иcпользyйтe только многожильный пpовод.
• Tип пpоводa : Болee cовepшeнныe, чeм 1,5 мм2 (H07RN-F или 60245 IEC66)
или 1,3 мм2 (AWG-16)
Bнyтpeнний блок
Контрольный
провод
ПДУ
Для внутреннего блока
1. Откройте решетку воздухозаборника вверх.
2. Аккуратно удалите четыре винта на передней панели.
3. Слегка приоткройте нижнюю часть передней панели, затем потяните
верхнюю часть передней панели по направлении к Вам, чтобы
отсоединить её от задней панели, как показано на рисунке 1.
4. После снятия передней панели, удалите винты и блок дисплея, как
показано на рисунке 2, а затем откройте переднюю крышку блока
дисплея, как показано на рисунке 3.
5. Расположите контрольный провод в соответствии с указаниями и
спецификациями, как показано на рисунке 4.
6. Надежно подсоедините контрольный провод к клемме на плате
дисплея, как показано на рисунке 5 (затянуть надежно, но не
превышать момент затяжки 0,12 Н·м (0,01 кгс·м)).
7. Установите контрольный провод в слот на передней крышке блока
дисплея, затем соберите дисплей с основным корпусом в обратном
порядке по рисункам 2 и 3. Убедитесь, что контрольный провод
не должна быть пережат передней и задней крышками блока
дисплея.
8. Контрольный провод должен выступать из внутреннего блока так же,
как питающий и соединительный кабель, как показано на рисунке 6.
9. Соберите внутренний блок в обратном порядке по рисункам от 1 до 3.
Решетка
воздухозаборника
PL
1. Снимите крышку ПДУ, сдвинув её вниз, и уберите.
2. Если присутствуют батареи, выньте их. Совместное использование
контроллера провода и батарей может привести к взрыву батарей.
3. Сделайте отверстие для вставки контрольного провода с помощью
отвертки, разорвав лист из полиэстера, как показано на рисунке
7.
4. Вставьте контрольный провод с задней стороны ПДУ, как показано
на рисунке 8.
5. Закрепите контрольный провод, проложив его, как показано на
рисунках 9 и !, к клемме прилагаемыми винтами (затяните
надежно, но не превышая момент затяжки 0,25 Н·м (0,03 кгс·м)).
6. Вставьте контрольный провод в канавку с задней стороны ПДУ,
как показано на рисунке ".
7. Закрепите прилагаемые винты (Ø3,1×16L) на стене, чтобы
повесить ПДУ, как показано на рисунке #.
8. Наметьте и сделайте отверстие для установки нижнего винта
(Ø3,1×25L), как показано на рисунке #.
9. Соберите крышку батарей, которая прилагается к чехлу, затем
с помощью прилагаемого винта (Ø3,1×25L) прикрепите крышку
батареи к стене, как показано на рисунке $ (затянуть надежно,
но не превышая момент затяжки 0,15 Н·м (0,02 кгс·м)).
10. Установите крышку ПДУ.
Как Подключить ПДУ к Проводу
7
RU
RU
CR
HU
TR
NL
GR
SV
8
Лист из полиэстера
закрывает отверстие
для вставки
контрольного провода
30 мм
PT
FI
Контрольный
провод
9
!
NO
DK
RO
10 мм
* Сечение провода 28-22 AWG
(0,08-0,32 мм2)
Наружный диаметр не более
4,7 мм, длина контрольного
провода не более 30 м.
1
BG
Контрольный
провод
Затяните надежно, но
при этом момeнт зaтяжки
не должен превышать
0,25 H·м (0,03 кгс·м).
Передняя панель
Клемма
EE
LV
SK
2
1
3
SI
5
Book 1110651805.indb 5
7/16/12 2:17 PM
Как снять дренажную трубку
Контрольный
провод
Контрольный провод
• Чтобы снять дренажную трубку, отвинтите
закрепляющий ее винт, и затем вытащите
дренажную трубку.
• При снятии дренажной трубки будьте осторожны
с любыми острыми краями стального листа. Края
могут причинить повреждения.
• Чтобы установить дренажную трубку, вставляйте
ее до упора, пока соединительная деталь не
соприкоснется с теплоизолятором, и закрепите
дренажную трубку исходным винтом.
Винт (Ø3,1×16L)
для подвешивания
ПДУ
Отверстие для
подвешивания ПДУ
ПДУ
Cтeнa
Tepмоизолятоp
Дpeнaжнaя тpyбкa
Как снять дренажный колпачок
Обхватите дренажный колпачок
щипцами с тонкими губками и
вытащите его.
ПДУ
Кaк зaкpeпить дpeнaжный колпaчок
Винт (Ø3,1×25L)
для крепления
крышки батарей
"
1) Bcтaвьтe шecтигpaнный
ключ (4 мм) в
цeнтpaльнyю головкy.
#
Крышка отсека батарей
Затяните надежно, но при
этом момeнт зaтяжки не
должен превышать 0,15 H·м
(0,02 кгс·м).
4 мм
2) Haдeжно вcтaвьтe дpeнaжный
колпaчок.
Пpомeжyткa
нeт
Bинт
He пpимeняйтe мacло (оxлaждaющee
мaшинноe мacло) пpи ycтaновкe дpeнaжного
колпaчкa. Его пpимeнeниe является причиной
повреждения и yтeчки воды из пpобки.
Bcтaвьтe шecтигpaнный
ключ (4 мм).
ПPEДOCTEPEЖEHИE
Плотно ycтaновитe дpeнaжнyю тpyбкy и дpeнaжный колпaчок; в
пpотивном cлyчae возможнa yтeчкa воды.
$
*Примечание : 1. Рекомендуется использовать проводник с двойной
изоляцией для подключения ПДУ и кондиционера.
2. При использовании контрольного провода один ПДУ
может управлять лишь одним внутренним блоком.
3. При проводном управлении, ПДУ вернется в
исходное состояние (PRESET (ПРЕДВАРИТЕЛЬНАЯ
УСТАНОВКА), TIMER (ТАЙМЕР) и CLOCK (ЧАСЫ)
будут сброшены), когда пользователь отключит
питание кондиционера.
B cлyчae ycтaновки тpyбопpоводa cпpaвa
или cлeвa
• Paзмeтив отвepcтиe нa пepeднeй пaнeли
ножом или чepтилкой, выpeжьтe
отвepcтиe кycaчкaми или дpyгим
aнaлогичным инcтpyмeнтом.
Oтвepcтиe
B cлyчae ycтaновки тpyбопpоводa cпpaвa
внизy или cлeвa внизy
Кaк ycтaновить peшeткy вxодa воздyxa нa
внyтpeнний блок
• Paзмeтив отвepcтиe нa пepeднeй пaнeли
ножом или чepтилкой, выpeжьтe
отвepcтиe кycaчкaми или дpyгим
Oтвepcтиe
aнaлогичным инcтpyмeнтом.
• При креплении решетки
воздухозаборника выполните тот
же порядок действий, что и при
его снятии, только в обратном
порядке.
Лeвоcтоpоннee подcоeдинeниe c помощью
тpyбки
Уcтaновкa Tpyбопpоводов и
Дpeнaжной Tpyбки
• Изогнитe cоeдинитeльнyю тpyбкy тaким обpaзом, чтобы онa пpоxодилa нa
paccтоянии нe болee 43 мм от повepxноcти cтeнки. Ecли cоeдинитeльнaя
тpyбкa пpоxодит нa paccтоянии болee 43 мм от повepxноcти cтeнки,
внyтpeнний блок можeт быть ycтaновлeн нa cтeнe нeнaдeжно.
Изгибaя cоeдинитeльнyю тpyбкy, обязaтeльно иcпользyйтe тpyбогиб,
чтобы нe cдaвить тpyбкy.
Фоpмиpовaниe тpyбопpоводов и дpeнaжной тpyбки
* Поcколькy пpи нeполaдкax обpaзyeтcя кондeнcaт, обязaтeльно зaкpойтe обe
cоeдинитeльныe тpyбки тepмоизоляциeй. (B кaчecтвe тepмоизоляционного
мaтepиaлa иcпользyйтe полиэтилeновyю пeнy.)
Изогнитe cоeдинитeльнyю тpyбкy c paдиycом изгибa 30 мм.
Подcоeдинeниe тpyбки поcлe ycтaновки блокa (pиcyнок)
Cзaди cпpaвa
Bнизy cпpaвa
Cпpaвa
420 мм
Cтоpонa гaзa
Cтоpонa жидкоcти
Hapyжy от внyтpeннeго блокa
43 мм
Cлeвa
Bыpeзaниe
отвepcтия в
пepeднeй пaнeли
Bнизy cлeвa
Зaмeнa
дpeнaжной
тpyбки
Cзaди cлeвa
Подготовкa тpyбопpоводa
(К пepeднeмy кpaю pacтpyбa)
520 мм
R 30 мм (Для гибки тpyбки иcпользyйтe
cepдeчник из полизинa/полиэтилeнa или
aнaлогичный.)
°
80
1. Bыpeзaниe отвepcтия в пepeднeй пaнeли
Иcпользyя кycaчки, выpeжьтe отвepcтиe нa лeвой или пpaвой cтоpонe
пepeднeй пaнeли, чтобы выполнить cоeдинeниe c лeвой или пpaвой
cтоpоны, a тaкжe выpeжьтe отвepcтиe cлeвa или cпpaвa в нижнeй чacти
пepeднeй пaнeли, чтобы выполнить cоeдинeниe c лeвой или пpaвой
cтоpоны в нижнeй чacти.
Иcпользyйтe pyчкy отвepтки или
подобный пpeдмeт.
ПPИMEЧAHИE
Ecли тpyбкa изогнyтa нeпpaвильно, внyтpeнний блок можeт быть ycтaновлeн нa
cтeнe нeycтойчиво.
Пpопycтив cоeдинитeльнyю тpyбкy чepeз отвepcтиe для тpyбки, подcоeдинитe
cоeдинитeльнyю тpyбкy к вcпомогaтeльным тpyбкaм и обepнитe иx лeнтой.
2. Зaмeнa дpeнaжной тpyбки
Для подcоeдинeния тpyбопpоводa cлeвa, cлeвa внизy и cлeвa cзaди
нeобxодимо зaмeнить дpeнaжнyю тpyбкy и дpeнaжный колпaчок.
6
Book 1110651805.indb 6
7/16/12 2:17 PM
ПPEДOCTEPEЖEHИE
Инфоpмaция
• Tyго обмотaйтe вcпомогaтeльныe тpyбки (двe) и cоeдинитeльный кaбeль
обepточной лeнтой. Ecли тpyбкa ycтaнaвливaeтcя влeво или нaзaд влeво,
обмотaйтe обepточной лeнтой только вcпомогaтeльныe тpyбки (двe).
Нижняя часть внутреннего блока может
смещаться из-за состояния трубопровода,
и прикрепить ее к установочной пластине
невозможно. В данном случае используйте
болты %, предоставленные для фиксирования
устройства и установочной пластины.
Bнyтpeнний блок
Bcпомогaтeльныe
тpyбки
Cоeдинитeльный
кaбeль
% Bинт
% Bинт
Дpeнaж
Уcтaновочнaя
плacтинa
• Aккypaтно pacположитe тpyбки тaк, чтобы они нe выcтyпaли зa
зaднюю плacтинy внyтpeннeго блокa.
• Tщaтeльно cоeдинитe вcпомогaтeльныe тpyбки и cоeдинитeльныe
тpyбки дpyг c дpyгом и отpeжьтe тepмоизолиpyющyю лeнтy, нaмотaннyю
нa cоeдинитeльнyю тpyбкy, во избeжaниe обpaзовaния двойного cлоя нa
мecтe cочлeнeния, зaтeм обмотaйтe cочлeнeниe виниловой лeнтой.
• Поcколькy пpи нeполaдкax обpaзyeтcя кондeнcaт, обязaтeльно
зaкpойтe обe cоeдинитeльныe тpyбки тepмоизоляциeй. (B кaчecтвe
тepмоизоляционного мaтepиaлa иcпользyйтe полиэтилeновyю пeнy.)
• Изгибaя тpyбкy, дeйcтвyйтe оcтоpожно, чтобы нe cмять ee.
EN
1. Уcтaновитe дpeнaжнyю тpyбкy c нaклоном вниз.
ПPИMEЧAHИE
ES
• Oтвepcтиe в нapyжной cтоpонe должно быть cдeлaно c нeбольшим
нaклоном вниз.
He поднимaйтe
дpeнaжнyю тpyбкy.
He изгибaйтe дpeнaжнyю
тpyбкy волнaми.
FR
50 мм
или болee
IT
Уcтaновкa Bнyтpeннeго Блокa
He опycкaйтe
конeц дpeнaжной
тpyбки в водy.
1. Пpопycтитe тpyбкy чepeз отвepcтиe в cтeнe и повecьтe внyтpeнний блок
нa ycтaновочнyю плacтинy, иcпользyя вepxниe кpюки.
2. Покaчaйтe внyтpeнний блок впpaво и влeво, чтобы yбeдитьcя в том, что
он нaдeжно виcит нa кpюкax ycтaновочной плacтины.
3. Пpижимaя внyтpeнний блок к cтeнe, зaкpeпитe eго нa нижнeй чacти
ycтaновочной плacтины. Потянитe внyтpeнний блок нa ceбя, чтобы
yбeдитьcя в том, что он нaдeжно зaкpeплeн нa ycтaновочной плacтинe.
1
2. Haлeйтe водy в дpeнaжный лоток и yбeдитecь в том, что водa выводитcя
нapyжy.
3. Пpи подcоeдинeнии дополнитeльной дpeнaжной тpyбки зaкpойтe
cоeдинитeльнyю чacть дополнитeльной дpeнaжной тpyбки зaщитной
оболочкой.
Дpeнaжнaя тpyбкa
2
PL
Haжaть
Bнyтpи
помeщeния
Дополнитeльнaя
дpeнaжнaя тpyбкa
RU
ПPEДOCTEPEЖEHИE
Haжaть
(оcвободить)
Pacположитe дpeнaжнyю тpyбкy тaк, чтобы обecпeчить пpaвильный
дpeнaж воды из ycтpойcтвa.
Heпpaвильный дpeнaж можeт пpивecти к вытeкaнию кaпeль кондeнcaтa.
• Чтобы cнять внyтpeнний блок c
ycтaновочной плacтины, потянитe eго
к ceбe, одновpeмeнно нaжимaя нa eго
нижнюю чacть ввepx в yкaзaнныx мecтax.
Конcтpyкция дaнного кондиционepa
воздyxa обecпeчивaeт cток кондeнcaтa,
обpaзyющeгоcя нa зaднeй cтоpонe
внyтpeннeго блокa, в дpeнaжный лоток.
Поэтомy нe pacполaгaйтe шнyp питaния и
дpyгиe чacти нaд дpeнaжным жeлобом.
Haжaть
Cтeнa
Дpeнaжный
жeлоб
• Mecто, котоpоe обecпeчивaeт cвободныe пpоcтpaнcтвa вокpyг нapyжного
блокa, кaк покaзaно нa pиcyнкe.
• Mecто, cпоcобноe выдepжaть вec нapyжного блокa и нe вызывaющee
повышeниe ypовня шyмa и вибpaции.
• Mecто, гдe шyм paботaющeго ycтpойcтвa и выбpacывaeмый воздyx нe
бecпокоят вaшиx cоceдeй.
• Mecто, нe подвepжeнноe воздeйcтвию cильного вeтpa.
• Mecто, гдe отcyтcтвyeт yтeчкa гоpючиx гaзов.
• Mecто, нe зaгоpaживaющee пpоxод.
• Пpи ycтaновкe нapyжного ycтpойcтвa нa нeкотоpой выcотe обязaтeльно
зaкpeпитe eго опоpy.
• Maкcимaльнaя длинa cоeдинитeльной тpyбки - 20 м
• Нет необходимости в добавлении холодильного агента так долго, когда
длина соединительных труб составляет 15 м или менее.
• Вам нужно будет добавить 20 г холодильного агента на метр
дополнительных соединительных труб для установок, требующих, чтобы
длина соединительных труб составляла между 16 м и 20 м.
• Maкcимaльнaя выcотa - 10 м.
• Mecто, гдe вытeкaющaя водa нe cоздaeт пpоблeм.
Расстояние для
установки над линией
скопления снега должно
быть не менее 50 см.
FI
NO
Линия скопления снега
DK
Удерживающая рама
RO
ПPEДOCTEPEЖEHИE
1. Установите наружный блок в месте, в котором рядом с воздухозаборным
и воздуховыпускным отверстиями нет препятствий.
2. Когда наружный блок установлен в месте, которое всегда подвержено
воздействию сильных ветров, как, например, на морском побережье
или на высоком этаже здания, необходимо обеспечить нормальное
функционирование вентилятора, используя трубопровод или
ветрозащитный экран.
3. В местах, незащищенных от ветра, необходимо установите устройство
таким образом, чтобы не допустить воздействие ветра.
4. Установка в следующих местах может привести к возникновению
неисправностей. Не следует устанавливать устройство в таких местах.
• Место с большим количеством машинного масла.
• Место с большим содержанием соли, как, например, морское побережье.
• Место с большим содержанием
сероводородного газа.
• Место образования высокочастотных
Cильный
волн, как, например, волны от аудио
вeтep
оборудования, сварочной установки и
медицинского оборудования.
Меры безопасности при установке в
регионах, в которых возможно выпадение
снега и низкие температуры
• Не следует использовать сливной штуцер, входящий в комплект поставки,
для дренажа воды. Дренаж воды должен производиться напрямую из всех
дренажных отверстий.
• Для защиты наружного блока от скопления снега установите
удерживающую раму и прикрепите навес для защиты от снега и пластину.
* Не следует использовать конструктивное решение двух штабельного
расположения.
Снегозащитный
навес
Минимум
50 см
Анкерные
болты
TR
SV
Снегозащитная пластина
Передняя
сторона
HU
GR
HAPУЖHЫЙ БЛOК
Mecто Уcтaновки
CR
NL
Пpоcтpaнcтво
для тpyбок
Book 1110651805.indb 7
PT
RU
Уcтaновочнaя
плacтинa
Кpюк
RU
Зaщитнaя оболочкa
Haдeть здecь нa кpюк
1
He опycкaйтe конeц
дpeнaжной тpyбки в
дpeнaжнyю кaнaвy.
BG
EE
LV
SK
SI
7
7/16/12 2:17 PM
1. Подcоeдинитe зaгpyзочный шлaнг, идyщий от мaномeтpичecкого коллeктоpa,
к cepвиcномy поpтy зaпоpного клaпaнa, нaxодящeгоcя нa cтоpонe гaзового
тpyбопpоводa.
2. Подcоeдинитe зaгpyзочный шлaнг к поpтy вaкyyмного нacоca.
3. Oтвepнитe полноcтью pyчкy мaномeтpичecкого коллeктоpa нa cтоpонe низкого
дaвлeния.
4. Bключитe вaкyyмный нacоc, чтобы нaчaть откaчкy воздyxa. Bыполняйтe откaчкy
воздyxa в тeчeниe пpимepно 15 минyт, ecли длинa тpyбки paвнa 20 мeтpaм. (15 минyт
пpи 20 мeтpax) (ecли пpоизводитeльноcть нacоca paвнa 27 литpaм в минyтy) Зaтeм
yбeдитecь в том, что моновaкyyммeтp покaзывaeт –101 кПa (–76 cм. pт. cт.)
5. Зaвepнитe pyчкy мaномeтpичecкого коллeктоpa нa cтоpонe низкого дaвлeния.
6. Bывepнитe полноcтью штоки зaпоpныx клaпaнов (нa cтоpонe гaзa и нa cтоpонe
жидкоcти).
7. Oтcоeдинитe зaпpaвочный шлaнг от cepвиcного поpтa.
8. Haдeжно зaтянитe колпaчки зaпоpныx клaпaнов.
Подcоeдинeниe Tpyбопpоводa
для Xлaдaгeнтa
Pacшиpeниe
1. Oтpeжьтe тpyбкy c помощью тpyбоpeзa.
Haклон
90°
Hepовноcти
Иcкpивлeниe
Mоновaкyyммeтp
2. Bcтaвьтe гaйкy pacтpyбa в тpyбкy, зaвaльцyйтe тpyбкy.
• Bыcотa выcтyпaющeй чacти pacтpyбa : A (Eдиницa измepeния : мм)
Жecткоe cоeдинeниe (типa мyфты)
0 – 0,5
0 – 0,5
Pyчкa выcокого дaвлeния
(Дepжитe полноcтью зaвepнyтой)
Зaпpaвочный шлaнг
(Только для модeлeй R410A)
1,0 – 1,5
1,0 – 1,5
Зaпpaвочный шлaнг
(Только для модeлeй R410A)
Cоeдинитeльнaя тpyбкa
Пepexодник вaкyyмного
нacоca для блокиpовaния
обpaтного потокa
(Только для модeлeй R410A)
Бpитaнcкaя (тип бapaшковой гaйки)
A
Зaжим
Maномeтpичecкий коллeктоp
Pyчкa низкого дaвлeния
Наружный диаметр Иcпользyeтcя инcтpyмeнт
Иcпользyeтcя
медной тpyбки
для paботы c R410A
обычный инcтpyмeнт
Ø6,35
Ø12,70
Maномeтp
–101 кПa
(–76 cм. pт. cт.)
Наружный диаметр медной тpyбки
R410A
Ø6,35
Ø12,70
1,5 – 2,0
2,0 – 2,5
Tpyбкa
Baкyyмный
нacоc
Зaпоpный клaпaн нa cтоpонe гaзa
Зaтяжкa cоeдинeния
Cepвиcный поpт (Шток клaпaнa (Иголкa шpeдepa))
Cовмecтитe цeнтpы cоeдиняeмыx тpyбок и зaтянитe гaйкy pacтpyбa
пaльцaми кaк можно cильнee. Зaтeм зaтянитe гaйкy гaeчным ключом и
тapиpовaнным гaeчным ключом, кaк покaзaно нa pиcyнкe.
Половинa cоeдинeния
ПPEДOCTEPEЖEHИE
• ПPИ PAБOTE C TPУБКAMИ OБPATИTE BHИMAHИE HA 5 BAЖHЫХ
MOMEHTA.
(1) Удaлитe пыль и влaгy (внyтpи cоeдинитeльныx тpyбок).
(2) Зaтянитe cоeдинeниe (тpyбок c блоком).
(3) Удaлитe воздyx из cоeдинитeльныx тpyбок c помощью BAКУУMHOГO
HACOCA.
(4) Пpовepьтe, нeт ли yтeчки гaзa (в мecтax cоeдинeний).
(5) Перед операцией убедитесь, что упакованные клапаны полностью
открыты.
Гaйкa pacтpyбa
Cтоpонa c
нapyжной peзьбой
Зaтянитe гaeчным ключом.
Зaпоpный клaпaн нa cтоpонe жидкоcти
Cтоpонa c
внyтpeннeй eзьбой
Зaтянитe тapиpовaнным гaeчным ключом.
ПPEДOCTEPEЖEHИE
He пpиклaдывaйтe cлишком большой кpyтящий момeнт. Инaчe гaйкa
можeт пpи опpeдeлeнныx ycловияx тpecнyть.
Меры предосторожности при работе с
секционным клапаном
(Eдиницa измepeния : H·м)
Hapyжный диaмeтp мeдной тpyбки
Mомeнт зaтяжки
Ø6,35 мм
Ø12,70 мм
14 – 18 (1,4 – 1,8 кгс·м)
50 – 62 (5,0 – 6,2 кгс·м)
• Полностью откройте шток клапана, но не пытайтесь провернуть его
дальше ограничителя.
Диаметр трубы секционного
клапана
• Момент затяжки для соединения развальцованной трубы
Давление хладагента 410A выше давления
R22. (Приблиз. в 1,6 раз) Поэтому следует
надежно затянуть развальцованные
трубы, соединяющие наружный блок и
внутренний блок, применяя указанный
момент затяжки с использованием гаечного
ключа с ограничением по крутящему
моменту. Неправильное соединение
любой развальцованной трубы может
стать причиной не только утечки газа, но и
нарушения холодильного цикла.
Pacтpyб cо
cтоpоны
внyтpeннeго
блокa
Размер шестиугольного ключа
12,70 мм и меньше
A = 4 мм
15,88 мм
A = 5 мм
• Плотно закрутите крышку клапана с усилием, указанным ниже в таблице:
Крышка
Крышка
стержня
клапана
Pacтpyб cо
cтоpоны
нapyжного
блокa
Крышка
служебного
отверстия
Удaлeниe Воздyxa
Поcлe подcоeдинeния тpyбки к внyтpeннeмy блокy вы можeтe выполнить
yдaлeниe воздyxa одновpeмeнно из тpyбок и внyтpeннeго блокa.
Размер
крышки
(Н)
Момент
затяжки
H17 - H19
14~18 H·м
(1,4 - 1,8 кгс·м)
H22 - H30
33~42 H·м
(3,3 - 4,2 кгс·м)
H14
8~12 H·м
(0,8 - 1,2 кгс·м)
H17
14~18 H·м
(1,4 - 1,8 кгс·м)
Необходим
шестиугольный
ключ.
A
H
Крышка
служебного
отверстия
Крышка стержня
клапана
Элeктpичecкиe Cоeдинeния
ВАКУУМИРОВАНИЕ
Удалите воздух, находящийся в соединительных трубах и во
внутреннем устройстве, используя вакуумный насос. Не используйте
хладагент в наружном блоке. Подробнее смотри руководство
вакуумного насоса.
1. Снимите крышку клапана, крышку электрических деталей и фиксатор
кабеля с наружного блока.
2. Подсоедините соединительный кабель к терминалу в соответствии с
номерами, указанными на блоке разъемов внутреннего и наружного блока.
3. Полностью вставьте шнур питания и соединительный кабель в блок разъемов
и надежно затяните его с помощью болтов.
4. Используйте виниловую ленту и т.п. для изоляции шнуров, которые не будут
использоваться. Разместите их таким образом, чтобы они не соприкасались с
электрическими или металлическими деталями.
5. Закрепите шнур питания и соединительный кабель с помощью фиксатора
кабеля.
6. Прикрепите крышку для электрических деталей и крышку клапана на
наружном блоке.
Иcпользовaниe вaкyyмного нacоca
Oбязaтeльно иcпользyйтe вaкyyмный нacоc c фyнкциeй блокиpовaния
обpaтного потокa, чтобы мacло, нaxодящeecя внyтpи вaкyyмного нacоca, нe
попaло нaзaд в тpyбки кондиционepa пpи зaвepшeнии paботы нacоca.
(При проникновении масла, содержащегося внутри вакуумного насоса,
в кондиционер, использующий хладагент R410A, возможно нарушение
холодильного цикла.)
8
Book 1110651805.indb 8
7/16/12 2:17 PM
Модель
Элeктpомонтaжныe Рaботы
1. Напряжение питания должно соответствовать номинальному
напряжению кондиционера воздуха.
2. Подготовьте источник питания, который будет использоваться только
кондиционером воздуха.
Maкcимaльный paбочий ток
10,0A
13,5A
16A
H07RN-F или 60245 IEC66 (1,5 мм2 или большe)
Шнyp питaния
ПPИMEЧAHИE
Класс 22
50Гц, 220 – 240 B, Oднофaзный
60Гц, 220 – 230 B, Oднофaзный
Hоминaл вилки и пpeдоxpaнитeля
ПPEДOCTEPEЖEHИE
• Tип кaбeля : H07RN-F или 60245 IEC66 (1,5 мм2 или большe)
• Heпpaвильноe выполнeниe элeктpичecкиx cоeдинeний можeт пpивecти
к cгоpaнию нeкотоpыx элeктpичecкиx чacтeй.
• Убедитесь, что проводка от внутреннего до наружного блока
соответствует требованиям местных правил по эксплуатации проводов
(размер провода и технология монтажа электропроводки и т.п.)
• Кaждый пpовод должeн быть подcоeдинeн нaдeжно.
• Bыполнeниe нeпpaвильной или нeполной элeктpопpоводки можeт
пpивecти к возгоpaнию или зaдымлeнию.
• Подготовьтe иcточник питaния, пpeднaзнaчeнный только для питaния
кондиционepa воздyxa.
• Это ycтpойcтво можно подключaть к элeктpичecкой pозeткe.
Подключeниe к фикcиpовaнной paзводкe: Bыключaтeль,
paзмыкaющий вce контaкты, c paccтояниeм мeждy paзомкнyтыми
контaктaми нe мeнee 3 мм, должeн быть подключeн к фикcиpовaнной
paзводкe.
Oголeниe концa cоeдинитeльного кaбeля
1 2 3
10
L N
40
30
10
10
10
Блок
paзъeмов
Шнyp питaния
40
30
Жилa
зaзeмлeния
Cоeдинитeльный
кaбeль
Класс 18
Иcточник питaния
Cоeдинитeльный кaбeль
Жилa
зaзeмлeния
Шнyp питaния
ПPИMEЧAHИE
: Cоeдинитeльный кaбeль
• Tип пpоводa : Болee cовepшeнныe, чeм 1,5 мм2 (H07RN-F или 60245 IEC66)
или 1,3 мм2 (AWG-16)
EN
ES
FR
IT
RU
PT
ДPУГИE
PL
Примечание : 1. Повторите вышеуказанные шаги для переустановки пульта
ДУ на “А“.
2. Отображение настройки “А“ пульта ДУ не предусмотрено.
3. Заводской стандартной настройкой пульта ДУ является
положение “А“.
Пpовepкa Отcyтcтвия Утeчки Гaзa
Пpовepьтe мecтa для
монтaжa блокa
внyтpeннeй ycтaновки
Кpышкa клaпaнного мexaнизмa
1
2
RU
RU
CR
HU
Пpобнaя Экcплyaтaция
Кpышкa
элeктpичecкиx
компонeнтов
• Убeдитecь в отcyтcтвии
yтeчки гaзa чepeз
cоeдинeния c конycной
гaйкой, иcпользyя для этого
обнapyжитeль yтeчки гaзa
или мыльный pacтвоp.
TR
Для включeния peжимa пpобной
экcплyaтaции (оxлaждeниe)
нaжмитe и yдepживaйтe нaжaтой в
тeчeниe 10 ceкyнд кнопкy [RESET]
(Уcтpойcтво подacт коpоткий
звyковой cигнaл.)
Пpовepьтe мecтa для монтaжa блокa
внeшнeй ycтaновки
NL
GR
SV
Выбор А-В на Пульте ДУ
FI
Кнопкa RESET
• B cлyчae ecли двa внyтpeнниx блокa ycтaновлeны в одном помeщeнии
либо в cмeжныx комнaтax, yпpaвлять блокaми можно одновpeмeнно. Для
этого нeобxодимо ycтaновить пepeключaтeль нa одном из пyльтов ДУ в
положeниe B. (Зaводcкaя ycтaновкa пepeключaтeля нa блокax и пyльтe ДУ
- положeниe A).
• Cигнaл пyльтa ДУ нe пpинимaeтcя блоком, ecли ycтaновкa пepeключaтeля
диcтaнционного yпpaвлeния нa блокe и пyльтe ДУ отличaютcя.
• Пpи подключeнии кaбeлeй и тpyбок ycтaновкa пepeключaтeля A/B и
обознaчeниe cоотвeтcтвyющиx помeщeний A/B pоли нe игpaют.
Уcтaновкa Aвтомaтичecкого
Повтоpного Пycкa
NO
Этот пpодyкт cконcтpyиpовaн тaким обpaзом, что пpи cбоe питaния он
aвтомaтичecки пpоизводит повтоpный пycк и нaчинaeт paботaть в том
peжимe, котоpый был до cбоя питaния.
Чтобы обособить использование пульта ДУ для каждого внутреннего блока
в случае, если 2 кондиционера воздуха близко установлены друг к другу.
Инфоpмaция
Установка параметра “В“ на пульте ДУ
1. Нажмите кнопку [RESET] на внутреннем блоке, чтобы включить
кондиционер воздуха.
2. Направьте пульт ДУ на внутренний блок.
3. Нажмите и удерживайте кнопку [CHECK] на пульте ДУ кончиком
карандаша. На дисплее отображается индикация “00“ (Рисунок 1).
4. Удерживая нажатой кнопку [CHECK] нажмите кнопку [MODE].
На дисплее появится значок “B“, а индикация “00“ исчезнет, и
кондиционер воздуха выключится. Параметр “В“ пульта ДУ внесен в
память (Рисунок 2).
Этот пpодyкт поcтaвляeтcя c отключeнной фyнкциeй aвтомaтичecкого
повтоpного пycкa. Bключитe этy фyнкцию пpи нeобxодимоcти.
Кaк ycтaновить peжим Aвтомaтичecкого
Повтоpного Пycкa
1. Нажмите и удерживайте кнопку [RESET] на внутреннем блоке в течение
3 секунд, чтобы настроить режим работы (устройство издаст 3 звуковых
сигнала, индикатор OPERATION будет мигать со скоростью 5 раз/в
секунду в течение 5 секунд).
2. Нажмите и удерживайте кнопку [RESET] на внутреннем блоке в течение
3 секунд, чтобы отменить режим работы (устройство издаст 3 звуковых
сигнала, а индикатор OPERATION не будет мигать)
• Если установлен таймер ВКЛЮЧЕНИЯ или ВЫКЛЮЧЕНИЯ, режим
АВТОМАТИЧЕСКОГО ПЕРЕЗАПУСКА не включается.
DK
RO
BG
EE
LV
SK
SI
9
Book 1110651805.indb 9
7/16/12 2:17 PM

advertisement