232-iLM Keypad
Specifications:
Case Dimensions:
6 1/2”L x 1 3/4”W x 1 1/8”D
Electrical:
5-12 VDC Only - reader
12-24 VDC/VAC - controller
Current Draw:
120ma maximum@ 12VDC
Temperature Tolerance:
-20ºF to 130ºF
Features:
• Sealed For Indoor or Outdoor Applications
• LED’s For Relay Status Indication
• Bell Output
• Surface mount
• Illuminated hardened keys
• Rated at greater than one million key cycles
• Two Piece Design Creates a Secure Installation
Use It:
• From light to Medium/Heavy duty applications
Applications:
• Low-Medium/Heavy Traffic Use
• Rough Service Environments
• Mullion Frame Mounting
For use with the following:
• IEI Self Contained Access Control.
Wire Harness Configuration
1 2
3 4
Functionality:
Combining elegant looks and mullion mount design in a rugged case, IEI’s new Open Technology Series Mullion keypad can be utilized for most applications. Designed to perform in meduim-high traffic and rough duty environments, the IEI Open Technology Series Mullion has hardened backlit keys. Encapsulated electronics makes the Mullion keypad suitable for indoor and outdoor installations . The keypad is activated by entering any 1-6 digit programmed code followed by the star * key. IEI also offers the Open Technology Series Mullion keypad as model SS-iLM, a keypad only version for use with an IEI controller or in 26 Bit Wiegand applications.
Packing List: (232-iLM)
IEI Open Technology Mullion keypad
IEI 232 Controller
Eight conductor wire harness
Three conductor wire harness
Hardware package for controller
8 x 1 1/4” Panhead Machine screws
(1)
(1)
(1)
(4)
(1)
(2)
8 x 1 1/4” Panhead wood/sheet metal screws (2)
6 x 32 5/64 allen head screw
5/64” Allen wrench
Instruction manual w/template
(1)
(1)
(1)
5
7
6
7
4
5
8
2
3
Pin
1
Wire color
Red
Black
White/Black
White/Yellow
Blue
Brown
White
White
6
8
Signal name
V in (+)
V in (-)
Data 0
Data 1
Not used
Not used
Bell Relay Contact (A)
Bell Relay Contact (B)
Wire Requirements:
Maximum distance with 6 conductor shielded :
18 AWG - 1000’
20 AWG - 500’
22 AWG - 250’
605 0800 rev 1.0
1 of 7
To Install the Mullion keypad:
Step 1:
Step 2:
Step 3:
• Use the template provided on last page to accurately mark the holes needed for mounting.
Drill the mounting holes with a 11/64 drill bit, also drill the hole for the wire run (size undetermined). Attach the mounting bracket to the mounting location.
• Be sure to strip back the insulator from the wire run, and tape the shield to the jacket.
• Connect the eight conductor harness to the Open Technology Series Keypad to the four conductor for an IEI controller as shown in the diagrams below.
• Place the Mullion keypad on the bracket, and secure with the provided allen head screw. For added security, the 6 x 32 5/64” allen head screw maybe replaced with any head style that you choose (i.e spanner head, allen with pin, etc..).
Wiring the Door-Gard Mullion Keypad to an IEI Controller
Keypad
Electrical
Tape
ê
WHITE\YELLOW
BLACK/WHITE
RED
BLACK
Electrical
Tape
ì
Insulator
Drain
Wire
è
48”
* Brown & Blue wires are not used when using an IEI controller
The controller should be mounted in a secure location that is not exposed to the elements. It is recomended that a filtered and regulated power supply be used to power the controller. This will greatly increase the performance and reliablity of the product.
Wiring the 232-ILM to an IEI Control unit requires a four conductor, stranded and shielded cable to be wired between two units. Maximum lengths are as follows: 22 AWG stranded : 250 feet
20 AWG stranded : 500 feet
18 AWG stranded : 1000 feet
At the Controller, connect the four conductor cable to the four pin connector on the Controller’s relay board, as shown in the diagram above. The drain wire at the Controller must be attached to ground. Ground is the V- terminal on TS1 of the controller if the power supply is grounded. At the mullion keypad, the drain wire and foil shield should be cut back with the insulator and taped with electrical tape. The eight conductor harness connects into the eight pin connector on the mullion keypad. Both wire harnesses are connected to each other, color to color, as shown above.
605 0800 rev 1.0
2 of 7
Wiring an IEI CONTROLLER
Basic Access Control with an
Electromagnetic Lock
Normally
Open Switch
Double Pull,
Doulbe Through
Input Loop Common
Door Position Input
Timed Egress Input
* If no contact in being used it must be jumped closed.
(White/orange + White wire)
â
Normally Closed
Door Contacts
NO NC
C
NO NC
C
NO NC
C
White/Orange
White
Brown
Programming
Switch
SW1
ALARM
SHUNT
TS 1
FORCED
DOOR
DOOR
AJAR
-Jumper on 2&3 for
12-15 VDC only
-Jumper on 1&2 for
15-24 VDC
12-24 VAC
TECH TIP:
Although the unit will operate with AC voltage, it is recommended that filtered and regulated DC voltage is used to increase system reliability.
12 or 24 volt AC/DC power supply
è
Note: If powering the keypad and the lock with the same power supply, Lock voltage must match power supply voltage
Magnetic Door Lock
( Fail Safe )
â Forced door & Door Ajar functions require a dedicated set of normally closed door contacts.
Normally
Open Switch
Double Pull,
Doulbe Through
Input Loop Common
Door Position Input
Timed Egress Input
* If no contact in being used it must be jumped closed.
(White/orange + White wire)
â
Normally Closed
Door Contacts
Basic Access Control with an Electric Door Strike
NO NC
C
NO NC
C
NO NC
C
White/Orange
White
Brown
Programming
Switch
SW1
ALARM
SHUNT
FORCED
DOOR
DOOR
AJAR
TS 1
-Jumper on 2&3 for
12-15 VDC only
-Jumper on 1&2 for
15-24 VDC
12-24 VAC
â Forced door
& Door Ajar functions require a dedicated set of nor mally closed door contacts.
TECH TIP:
Although the unit will operate with AC voltage, it is recommended that filtered and regulated
DC voltage is used to increase system reliability.
12 or 24 volt AC/DC power supply
è
Note: If powering the keypad and the lock with the same power supply,
Lock voltage must match power sup ply voltage
3 of 7
Electric door strike
( fail secure )
605 0800 rev 1.0
Wiring an IEI CONTROLLER
Siren
V-
Integrated Access
Control with an
Electromagnetic Lock
To alarm panel closed circuit loop
TECH TIP:
Although the unit will operate with AC voltage, it is recommended that filtered and regulated DC voltage is used to increase system reliability.
V+
Sounder
Normally
Open Switch
Double Pull,
Doulbe Through
â
Normally Closed
Door Contacts
NO NC
C
NO NC
C
NO NC
C
Input Loop Common
Door Position Input
Timed Egress Input
* If no contact in being used it must be jumped closed.
(White/orange + White wire)
White/Orange
White
Brown
Programming
Switch
SW1
ALARM
SHUNT
TS 1
FORCED
DOOR
DOOR
AJAR
-Jumper on 2&3 for
12-15 VDC only
-Jumper on 1&2 for
15-24 VDC
12-24 VAC
â Forced door & Door Ajar functions require a dedicated set of normally closed door contacts.
12 or 24 volt AC/DC power supply
è
Note: If powering the keypad and the lock with the same power supply,
Lock voltage must match power supply voltage Magnetic door lock ( fail safe )
Siren
Integrated Access
Control with an
Electric Door Strike
To alarm panel closed circuit loop
V-
V+
Normally
Open Switch
Double Pull,
Doulbe Through
â
Normally Closed
Door Contacts
NO NC
C
NO NC NO NC
C C
Input Loop Common
Door Position Input
Timed Egress Input
* If no contact in being used it must be jumped closed.
(White/orange + White wire)
White/Orange
White
Brown
Programming
Switch
SW1
ALARM
SHUNT
FORCED
DOOR
DOOR
AJAR
TS 1
-Jumper on 2&3 for
12-15 VDC only
-Jumper on 1&2 for
15-24 VDC
12-24 VAC
TECH TIP:
Although the unit will operate with AC voltage, it is recommended that filtered and regulated DC voltage is used to increase system reliability.
12 or 24 volt AC/DC power supply
Note: If powering the keypad and the lock with the same power supply, Lock voltage must match power supply voltage
Electric door strike
( fail secure )
Sounder
â Forced door &
Door Ajar functions require a dedicated set of normally closed door contacts.
605 0800 rev 1.0
4 of 7
Wiring the bell output to a speaker
With the 232-iLM you can use the bell button to trigger an external device such as a door bell or like devices that require a momentary closer to operate. This is easily accomplished by either using the dry contact provided or you can run 12 through 24 volts AC/DC through one leg of the bell output (A) and connecting the other leg (B) to the power in on your device. Then connect the negative connection on your device to the negative on your power supply (as shown below).
232-iLM wire harness
To IEI controller
Speaker
To separate power supply
System Defaults:
The Open Technology Mullion Keypad is designed for easy installation in a minimum amount of time. The following default values have been factory programmed.
Front End Designation HFE (Hub Front End)
Mullion Keypad Program Code 6789
Audible Key Press Feedback On
Visual Key Press Feedback On
Log Event Recording
Keypad illumination
Keypad Dimming
Door bell select
Door bell duration
Backlighting
IN
Enabled
Enabled
Enabled
Continuous
Dims 15 seconds after last key-press
Controller Defaults:
Main relay 5 seconds
Forced door 10 seconds
Keypad Active OFF
Auto Entry OFF
Master code
Door ajar
Keypress feedback
1234
30 seconds
ON
If it is necessary to change any of these defaults, please refer to the Programming Options Chart on page 6.
Self Test: While the unit is powered up, enter the following on the Mullion keypad: 7890#123456
*
. If all 12 keypresses have been verified, the keypad will enter self test mode. The LED’s will alternate three times and the sounder will beep three times followed by a flickering yellow LED. Press any key to return to normal operation.
605 0800 rev 1.0
5 of 7
Programming The 232-iLM
All programming is controlled by a unique Master Programming Code.
Components Requiring Programming:
• Open Technology Mullion Keypad (default program code- 6789)
• IEI 232 Controller (default Master Code 1234): All PIN number additions, deletions, access to control functions.
Open Technology Mullion Program Options Chart
To Enter program mode: 099 # “program code” * (Default program code 6789)
The keypad’s yellow LED will flash twice rapidly indicating that you are in program mode.
OPTION ENTER COMMAND ON 232 iLM KEYPAD
Change Program Code
Visual Key-press feedback on
Visual Key-press feedback off
Audible Key-press feedback on
Audible key-press feedback off
Default Mullion keypad to IEI Controller mode
Default Mullion keypad to 26 bit Wiegand mode
90 # 0 # 0 # “new code” * “repeat code” *
91 # 0 # 1 # * *
91 # 0 # 0 # * *
91 # 1 # 1 # * *
91 # 1 # 0 # * *
96 # 0 # 0 # * *
96 # 1 # 1 # * *
Programming the Bell output
To enable the door bell feature
To diable the door bell feature
91 # 13 # 1 #
91 # 13 # 0 #
* *
* *
To set door bell duration
To set door bell to continuous
92 # 4 # (Time) # * * (time must be set in a two digit format, 01-99)
90 # 4 # 0 # * *
While you are programming, the * key represents a funtion similar to enter. After the * key is pressed the first time during the command, the yellow LED will speed up. After you press the * key a second time, the yellow will return to a slow flash. If the yellow LED comes on solid while programming, this is an indication of an error. Press the * key once, this should clear error and return to a slow flash, allowing you to re-enter the last programming command.
TO PROGRAM USERS AND CONTROLLER OUTPUT FUNCTIONALITY, PLEASE REFER TO
THE “SELF CONTAINED ACCESS CONTROL FEATURES AND PROGRAMMING GUIDE” FOR
A COMPLETE EXPLANATION AND HOW TO INSTRUCTIONS.
605 0800 rev 1.0
6 of 7
System Defaulting the Open Technology Mullion via wiring
If the four data wires are shorted in one of the two configurations shown below on power up, the option will be set.
Remove power after you hear the 3 beeps then reconnect the data lines to their proper working configuration.
Defaults Mullion and sets it in IEI Controller Front End mode.
Red
Black
Wht/Blk
Wht/Yel
Blue
Brown
- +12VDC
- GND
Defaults Mullion and sets it in Wiegand 26 bit mode.
Red
Black
Wht/Blk
Wht/Yel
Blue
Brown
+12VDC
- GND
(DAO)
(DA1)
(LED 1)
(Not Used)
If the local program code is lost or forgotten, power down the system, connect the wire harness as shown below then power the system up. Change your local program code then power down the system and restore the wire harness to its original configuration and power back up.
Red
Black
Wht/Blk
Wht/Yel
Blue
Brown
- +12VDC
- GND
- No connection
If this product does not seem to operate properly, please have your product model number ready and call our Technical
Department toll free at 1-800-343- 9502 or within MA (781-821-5566) Monday -Friday 8:00 am-7:00 pm EST.
We understand your time is valuable, and we know that calling our Technical Support Department will ensure that you’ll make the most profit possible with your IEI product. Thank you for your purchase. We appreciate your business.
International Electronics,Inc.(IEI) warrants its products to be free from defects in material and workmanship, when they have been installed in accordance with the manufacturer’s instructions, and have not been modified or tampered with. IEI does not assume any responsibility for damage or injury to person or property due to improper care, storage handling, abuse, misuse, normal wear and tear, or an act of God.
IEI’s sole responsibility is limited to the repair (at IEI’s option)or the replacement of the defective product or part when sent to IEI’s facility (freight and insurance charges prepaid), after obtaining IEI’s Return Merchandise Authorization. IEI will not be liable to the purchaser or any one else for incidental or consequential damages arising from any defect in, or malfunction of, its products.
This warranty shall expire two years after shipping date. Except as stated above, IEI makes no warranties, either express or implied, as to any matter whatsoev er, including, without limitation to, the condition of its products, their merchantability, or fitness for any particular.
INTERNATIONAL
ELECTRONICS, INC
TM
INTERNATIONAL ELECTRONICS, INC.
427 TURNPIKE STREET, CANTON, MA 02021 U.S.A.
800-343-9502, 781-821-5566
781-821-4443 (FAX)
FAX INFORMATION CENTER 781-821-0734 (FROM YOUR FAX MACHINE)
Visit our website for Access Control & Glassbreak information,
New Products, Specifications, Applications, Seminars, and Partners
@ www.ieib.com
605 0800 rev 1.0
7 of 7
6 1/4”
Mounting Template for iLM
1 7/16”
3 3/8”
1 7/16”
Diameter of the mounting holes -11/64”
Diameter of the wiring hole -7/8”
This product is designed as a surface mountable product. The access hole for the wires is determined by the amount of wires that will run through the mounting surface.
605 0800 rev 1.0