Mitsubishi Electric | A172SHCPUN | Mitsubishi Electric Corporation: A Series Computer Link

Mitsubishi Electric Corporation
A Series Computer
Link Driver
1
System Configuration....................................................................................................... 3
2
Selection of External Device ............................................................................................ 9
3
Example of Communication Setting ............................................................................... 10
4
Setup Items .................................................................................................................... 26
5
Cable Diagram ............................................................................................................... 31
6
Supported Device........................................................................................................... 49
7
Device Code and Address Code.................................................................................... 53
8
Error Messages.............................................................................................................. 54
1
A Series Computer Link Driver
Introduction
This manual describes how to connect the Display and the External Device (target PLC).
In this manual, the connection procedure will be described by following the below sections:
1
System Configuration
This section shows the types of External
Devices which can be connected and SIO
type.
)"1 System Configuration" (page 3)
2
Selection of External Device
Select a model (series) of the External
Device to be connected and connection
method.
)"2 Selection of External Device" (page 9)
3
Example of Communication Settings
This section shows setting examples for
communicating between the Display and
the External Device.
)"3 Example of Communication Setting"
4
Setup Items
This section describes communication
setup items on the Display.
Set communication settings of the Display
with GP-Pro Ex or in off-line mode.
)"4 Setup Items" (page 26)
5
Cable Diagram
This section shows cables and adapters
for connecting the Display and the
External Device.
)"5 Cable Diagram" (page 31)
Operation
GP-Pro EX Device/PLC Connection Manual
2
(page 10)
A Series Computer Link Driver
1
System Configuration
The system configuration in the case when the External Device of Mitsubishi Electric Corp. and the Display are
connected is shown.
Series
CPU
A2ACPU
A2ACPU-S1
A3ACPU
A2UCPU
A2UCPU-S1
A3UCPU
A4UCPU
MELSEC
AnA
Series
Link I/F
AJ71C24-S6
AJ71C24-S8
AJ71UC24
A1SJ71C24-R2
A1SJ71UC24-R2
A2USCPU
A2USHCPU-S1
A1SJ71C24-R4
A1SJ71UC24-R4
GP-Pro EX Device/PLC Connection Manual
3
SIO Type
Setting Example
Cable Diagram
RS232C
Setting Example 1
(page 10)
Cable Diagram 1
(page 31)
RS422/485
(4wire)
Setting Example 5
(page 18)
Cable Diagram 2
(page 33)
RS422/
485(4Wire)
Multilink
Setting Example 5
(page 18)
Cable Diagram 4
(page 41)
RS232C
Setting Example 2
(page 12)
Cable Diagram 1
(page 31)
RS422/485
(4wire)
Setting Example 6
(page 20)
Cable Diagram 2
(page 33)
RS422/
485(4Wire)
Multilink
Setting Example 6
(page 20)
Cable Diagram 4
(page 41)
RS232C
Setting Example 3
(page 14)
Cable Diagram 3
(page 39)
RS422/485
(4wire)
Setting Example 7
(page 22)
Cable Diagram 2
(page 33)
RS422/
485(4Wire)
Multilink
Setting Example 7
(page 22)
Cable Diagram 4
(page 41)
A Series Computer Link Driver
Series
CPU
Link I/F
AJ71C24
AJ71C24-S3
AJ71C24-S6
AJ71C24-S8
A1NCPU
A2NCPU
A2NCPU-S1
A3NCPU
AJ71UC24
MELSEC
AnN
Series
A1SCPU
A1SJCPU
A1SJHCPU
A1SHCPU
A2SHCPU
A1SJ71C24-R2
A1SJ71UC24-R2
A1SJ71C24-R4
A1SJ71UC24-R4
A0J2CPU
A0J2HCPU
A0J2-C214-S1
A2CCPUC24
Link port
on CPU
Q2ACPU
Q2ACPU-S1
Q3ACPU
Q4ACPU
Q4ARCPU
MELSEC
QnA
Series
AJ71UC24
A1SJ71UC24-R2
A1SJ71UC24-PRF
Q2ASCPU
Q2ASCPU-S1
Q2ASHCPU
Q2ASHCPU-S1
A1SJ71UC24-R4
GP-Pro EX Device/PLC Connection Manual
4
SIO Type
Setting Example
Cable Diagram
RS232C
Setting Example 1
(page 10)
Cable Diagram 1
(page 31)
RS422/485
(4wire)
Setting Example 5
(page 18)
Cable Diagram 2
(page 33)
RS422/
485(4Wire)
Multilink
Setting Example 5
(page 18)
Cable Diagram 4
(page 41)
RS232C
Setting Example 2
(page 12)
Cable Diagram 1
(page 31)
RS422/485
(4wire)
Setting Example 6
(page 20)
Cable Diagram 2
(page 33)
RS422/
485(4Wire)
Multilink
Setting Example 6
(page 20)
Cable Diagram 4
(page 41)
RS232C
Setting Example 3
(page 14)
Cable Diagram 3
(page 39)
RS422/485
(4wire)
Setting Example 7
(page 22)
Cable Diagram 2
(page 33)
RS422/
485(4Wire)
Multilink
Setting Example 7
(page 22)
Cable Diagram 4
(page 41)
RS422/485
(4wire)
Setting Example 8
(page 24)
Cable Diagram 2
(page 33)
RS422/
485(4Wire)
Multilink
Setting Example 8
(page 24)
Cable Diagram 4
(page 41)
RS232C
Setting Example 4
(page 16)
Cable Diagram 3
(page 39)
RS232C
Setting Example 2
(page 12)
Cable Diagram 1
(page 31)
RS422/485
(4wire)
Setting Example 6
(page 20)
Cable Diagram 2
(page 33)
RS422/
485(4Wire)
Multilink
Setting Example 6
(page 20)
Cable Diagram 4
(page 41)
RS232C
Setting Example 3
(page 14)
Cable Diagram 3
(page 39)
RS422/485
(4wire)
Setting Example 7
(page 22)
Cable Diagram 2
(page 33)
RS422/
485(4Wire)
Multilink
Setting Example 7
(page 22)
Cable Diagram 4
(page 41)
A Series Computer Link Driver
Series
CPU
Link I/F
A1SJ71UC24-R2
A1SJ71UC24-PRF
MELSEC
Q Series
Q02CPU-A
Q02HCPU-A
Q06HCPU-A
A1SJ71UC24-R4
SIO Type
Setting Example
Cable Diagram
RS232C
Setting Example 3
(page 14)
Cable Diagram 3
(page 39)
RS422/485
(4wire)
Setting Example 7
(page 22)
Cable Diagram 2
(page 33)
RS422/
485(4Wire)
Multilink
Setting Example 7
(page 22)
Cable Diagram 4
(page 41)
„ Connection Configuration
•
1:1 Connection
Display
•
External Device
1:n Connection
External Device
External Device
External Device
Display
•
1:n Connection (when communicating via network)
You can access other stations via MELSECNET/10, MELSECNET(II), MELSECNET/B.
Display
Serial
MELSECNET/H,MELSECNET/10
Ethenet
External Device
Available to connect
max 16 units
External Device
GP-Pro EX Device/PLC Connection Manual
External Device
5
A Series Computer Link Driver
•
n:1 Connection (Multilink connection)
Maximum number of connectable units: 16 units
Display
Display
Display
External Device
• The maximum number of connectable Displays is 16 units. However, keeping performance in
consideration, the number of Displays that can be substantially used is up to 4.
•
n:m Connection (Multilink connection)
Maximum number of connectable units: 16 units
Display
Display
Display
External Device External Device
Maximum number of connectable units: 16 units per Display
• The maximum number of connectable Displays is 16 units. However, keeping performance in
consideration, the number of Displays that can be substantially used is up to 4.
GP-Pro EX Device/PLC Connection Manual
6
A Series Computer Link Driver
„ IPC COM Port
When connecting IPC with an External Device, the COM port used depends on the series and SIO type. Please
refer to the IPC manual for details.
Usable port
Usable Port
Series
RS-232C
*1
RS-422/485(4 wire)
RS-422/485(2 wire)
PS-2000B
COM1 , COM2,
COM3*1, COM4
-
-
PS-3450A, PS-3451A,
PS3000-BA, PS3001-BD
COM1, COM2*1*2
COM2*1*2
COM2*1*2
PS-3650A, PS-3651A
COM1*1
-
-
PS-3700A (Pentium®4-M)
PS-3710A
COM1*1, COM2*1,
COM3*2 , COM4
COM3*2
COM3*2
PS-3711A
COM1*1, COM2*2
COM2*2
COM2*2
PL-3000B, PL-3600T,
PL-3600K, PL-3700T,
PL-3700K, PL-3900T
COM1*1*2, COM2*1,
COM3, COM4
COM1*1*2
COM1*1*2
*1
The RI/5V can be switched. Use the IPC’s switch to change if necessary.
*2
Set up the SIO type with the DIP switch. Please set up as follows according to SIO type to be used.
DIP switch setting: RS-232C
DIP switch
1
*1
Setting
*1
OFF
Description
Reserved (always OFF)
2
OFF
3
OFF
4
OFF
Output mode of SD (TXD) data: Always output
5
OFF
Terminal resistance (220Ω) insertion to SD (TXD): None
6
OFF
Terminal resistance (220Ω) insertion to RD (RXD): None
7
OFF
Short-circuit of SDA (TXA) and RDA (RXA): Not available
8
OFF
Short-circuit of SDB (TXB) and RDB (RXB): Not available
9
OFF
10
OFF
SIO type: RS-232C
RS (RTS) Auto control mode: Disabled
When using PS-3450A, PS-3451A, PS3000-BA and PS3001-BD, turn ON the set value.
GP-Pro EX Device/PLC Connection Manual
7
A Series Computer Link Driver
DIP switch setting: RS-422/485 (4 wire)
*1
DIP switch
Setting
Description
1
OFF
2
ON
3
ON
4
OFF
Output mode of SD (TXD) data: Always output
5
OFF
Terminal resistance (220Ω) insertion to SD (TXD): None
6
OFF
Terminal resistance (220Ω) insertion to RD (RXD): None
7
OFF
Short-circuit of SDA (TXA) and RDA (RXA): Not available
8
OFF
Short-circuit of SDB (TXB) and RDB (RXB): Not available
Reserved (always OFF)
SIO type: RS-422/485
*1
9
OFF
10
OFF*1
RS (RTS) Auto control mode: Disabled
When the connection configuration are the n:1 and n:m connections (both Multilink connections),
turn ON the set value.
DIP switch setting: RS-422/485 (2 wire)
DIP switch
Setting
1
OFF
2
ON
3
ON
4
OFF
Output mode of SD (TXD) data: Always output
5
OFF
Terminal resistance (220Ω) insertion to SD (TXD): None
6
OFF
Terminal resistance (220Ω) insertion to RD (RXD): None
7
ON
Short-circuit of SDA (TXA) and RDA (RXA): Available
8
ON
Short-circuit of SDB (TXB) and RDB (RXB): Available
9
ON
10
ON
GP-Pro EX Device/PLC Connection Manual
Description
Reserved (always OFF)
SIO type: RS-422/485
RS (RTS) Auto control mode: Enabled
8
A Series Computer Link Driver
2
Selection of External Device
Select the External Device to be connected to the Display.
Setup Items
Setup Description
Maker
Select the maker of the External Device to be connected. Select "Mitsubishi Electric
Corporation".
Driver
Select a model (series) of the External Device to be connected and connection method.
Select "A Series Computer Link".
Check the External Device which can be connected in "A Series Computer Link" in system
configuration.
"1 System Configuration" (page 3)
)
Use System Area
Check this option when you synchronize the system data area of Display and the device
(memory) of External Device. When synchronized, you can use the ladder program of
External Device to switch the display or display the window on the display.
Cf. GP-Pro EX Reference Manual "Appendix 1.4 LS Area (Direct Access
Method)"
This can be also set with GP-Pro EX or in off-line mode of Display.
Cf. GP-Pro EX Reference Manual "5.17.6 [System Settings] Setting Guide,
[Display Unit] Settings Guide, System Area Settings"
Cf. Maintenance/Troubleshooting Manual "2.15.1 Settings common to all
Display models, [Main Unit Settings] Settings Guide, System Area Settings"
Port
Select the Display port to be connected to the External Device.
GP-Pro EX Device/PLC Connection Manual
9
A Series Computer Link Driver
3
Example of Communication Setting
Examples of communication settings of the Display and the External Device, recommended by Pro-face, are
shown.
When you use the A Series, use GP-Pro EX and the ladder software to set as below.
3.1
Setting Example 1
„ Settings of GP-Pro EX
‹ Communication Settings
To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace.
‹ Device Setting
To display the setting screen, click
([Setting]) of External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
When you connect multiple External Device, click
from [Device-Specific Settings] of [Device/PLC
Settings] to add another External Device.
GP-Pro EX Device/PLC Connection Manual
10
A Series Computer Link Driver
„ Setting of External Device
Use the DIP switch of the Computer Link Unit for setting. Please refer to the manual of the External Device for
more details.
‹ Mode Setting Rotary Switch
Settings
4
Setup Description
Protocol mode in Form 4
‹ Communication Setting DIP Switch
DIP
Switch
Settings
SW11
OFF
Main channel setting
SW12
OFF
Data bit setting
SW13
OFF
SW14
ON
SW15
ON
SW16
ON
Parity bit setting whether enable or disable
SW17
ON
Parity setting whether Even or Odd
SW18
ON
Stop bit setting
SW21
ON
Sum check setting whether enable or disable
SW22
ON
Write setting during RUN whether enable or
disable
SW23
OFF
Termination resistance on the sending side whether
exist or not exist
SW24
OFF
Termination resistance on the receiving side
whether exist or not exist
Setup Description
Transmission speed setting
‹ Station Setting Rotary Switch
Rotary
Switch
Settings
X10
0
X1
0
Setup Description
Station No. setting
GP-Pro EX Device/PLC Connection Manual
11
A Series Computer Link Driver
3.2
Setting Example 2
„ Settings of GP-Pro EX
‹ Communication Settings
To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace.
‹ Device Setting
To display the setting screen, click
([Setting]) of External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
When you connect multiple External Device, click
from [Device-Specific Settings] of [Device/PLC
Settings] to add another External Device.
GP-Pro EX Device/PLC Connection Manual
12
A Series Computer Link Driver
„ Setting of External Device
Use the DIP switch of the Computer Link Unit for setting. Please refer to the manual of the External Device for
more details.
‹ Mode Setting Rotary Switch
Settings
4
Setup Description
Protocol mode in Form 4
‹ Communication Setting DIP Switch
DIP
Switch
Settings
SW11
OFF
Main channel setting
SW12
OFF
Data bit setting
SW13
OFF
SW14
ON
SW15
ON
SW16
ON
Parity bit setting whether enable or disable
SW17
ON
Parity setting whether Even or Odd
SW18
ON
Stop bit setting
SW21
ON
Sum check setting whether enable or disable
SW22
ON
Write setting during RUN whether enable or
disable
SW23
ON
Computer link/Multiple drop link selection
SW24
Unused
Setup Description
Transmission speed setting
Unused
‹ Station Setting Rotary Switch
Rotary
Switch
Settings
X10
0
X1
0
Setup Description
Station No. setting
GP-Pro EX Device/PLC Connection Manual
13
A Series Computer Link Driver
3.3
Setting Example 3
„ Settings of GP-Pro EX
‹ Communication Settings
To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace.
‹ Device Setting
To display the setting screen, click
([Setting]) of External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
When you connect multiple External Device, click
from [Device-Specific Settings] of [Device/PLC
Settings] to add another External Device.
GP-Pro EX Device/PLC Connection Manual
14
A Series Computer Link Driver
„ Setting of External Device
Use the DIP switch of the Computer Link Unit for setting. Please refer to the manual of the External Device for
more details.
‹ Mode Setting Rotary Switch
Settings
4
Setup Description
Protocol mode in Form 4
‹ Communication Setting DIP Switch
DIP
Switch
Settings
SW03
Unused
SW04
ON
SW05
OFF
SW06
ON
SW07
ON
SW08
OFF
Data bit setting
SW09
ON
Parity bit setting whether enable or disable
SW10
ON
Parity setting whether Even or Odd
SW11
ON
Stop bit setting
SW12
ON
Sum check setting whether enable or disable
Setup Description
Unused
Write setting during RUN whether enable or
disable
Transmission speed setting
GP-Pro EX Device/PLC Connection Manual
15
A Series Computer Link Driver
3.4
Setting Example 4
„ Settings of GP-Pro EX
‹ Communication Settings
To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace.
‹ Device Setting
To display the setting screen, click
([Setting]) of External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
When you connect multiple External Device, click
from [Device-Specific Settings] of [Device/PLC
Settings] to add another External Device.
GP-Pro EX Device/PLC Connection Manual
16
A Series Computer Link Driver
„ Setting of External Device
Use the DIP switch of the Computer Link Unit for setting. Please refer to the manual of the External Device for
more details.
‹ Mode Setting Rotary Switch
Settings
4
Setup Description
Protocol mode in Form 4
‹ Communication Setting DIP Switch
DIP
Switch
Settings
SW11
OFF
SW12
ON
SW13
ON
SW14
ON
Data bit setting
SW15
ON
Parity bit setting whether enable or disable
SW16
ON
Parity setting whether Even or Odd
SW17
ON
Stop bit setting
SW18
ON
Sum check setting whether enable or disable
SW19
ON
Main channel setting
SW20
OFF
Write setting during RUN whether enable or
disable
Setup Description
Transmission speed setting
‹ Station Setting Rotary Switch
Rotary
Switch
Settings
X10
0
X1
0
Setup Description
Station No. setting
GP-Pro EX Device/PLC Connection Manual
17
A Series Computer Link Driver
3.5
Setting Example 5
„ Settings of GP-Pro EX
‹ Communication Settings
To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace.
‹ Device Setting
To display the setting screen, click
([Setting]) of External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
When you connect multiple External Device, click
from [Device-Specific Settings] of [Device/PLC
Settings] to add another External Device.
GP-Pro EX Device/PLC Connection Manual
18
A Series Computer Link Driver
„ Setting of External Device
Use the DIP switch of the Computer Link Unit for setting. Please refer to the manual of the External Device for
more details.
‹ Mode Setting Rotary Switch
Settings
8
Setup Description
Protocol mode in Form 4
‹ Communication Setting DIP Switch
DIP
Switch
Settings
SW11
ON
Main channel setting
SW12
OFF
Data bit setting
SW13
OFF
SW14
ON
SW15
ON
SW16
ON
Parity bit setting whether enable or disable
SW17
ON
Parity setting whether Even or Odd
SW18
ON
Stop bit setting
SW21
ON
Sum check setting whether enable or disable
SW22
ON
Write setting during RUN whether enable or
disable
SW23
ON
Termination resistance on the sending side whether
exist or not exist
SW24
ON
Termination resistance on the receiving side
whether exist or not exist
Setup Description
Transmission speed setting
‹ Station Setting Rotary Switch
Rotary
Switch
Settings
X10
0
X1
0
Setup Description
Station No. setting
GP-Pro EX Device/PLC Connection Manual
19
A Series Computer Link Driver
3.6
Setting Example 6
„ Settings of GP-Pro EX
‹ Communication Settings
To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace.
‹ Device Setting
To display the setting screen, click
([Setting]) of External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
When you connect multiple External Device, click
from [Device-Specific Settings] of [Device/PLC
Settings] to add another External Device.
GP-Pro EX Device/PLC Connection Manual
20
A Series Computer Link Driver
„ Setting of External Device
Use the DIP switch of the Computer Link Unit for setting. Please refer to the manual of the External Device for
more details.
‹ Mode Setting Rotary Switch
Settings
8
Setup Description
Protocol mode in Form 4
‹ Communication Setting DIP Switch
DIP
Switch
Settings
SW11
ON
Main channel setting
SW12
OFF
Data bit setting
SW13
OFF
SW14
ON
SW15
ON
SW16
ON
Parity bit setting whether enable or disable
SW17
ON
Parity setting whether Even or Odd
SW18
ON
Stop bit setting
SW21
ON
Sum check setting whether enable or disable
SW22
ON
Write setting during RUN whether enable or
disable
SW23
ON
Computer link/Multiple drop link selection
SW24
Unused
Setup Description
Transmission speed setting
Unused
‹ Station Setting Rotary Switch
Rotary
Switch
Settings
X10
0
X1
0
Setup Description
Station No. setting
GP-Pro EX Device/PLC Connection Manual
21
A Series Computer Link Driver
3.7
Setting Example 7
„ Settings of GP-Pro EX
‹ Communication Settings
To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace.
‹ Device Setting
To display the setting screen, click
([Setting]) of External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
When you connect multiple External Device, click
from [Device-Specific Settings] of [Device/PLC
Settings] to add another External Device.
GP-Pro EX Device/PLC Connection Manual
22
A Series Computer Link Driver
„ Setting of External Device
Use the DIP switch of the Computer Link Unit for setting. Please refer to the manual of the External Device for
more details.
‹ Mode Setting Rotary Switch
Settings
8
Setup Description
Protocol mode in Form 4
‹ Communication Setting DIP Switch
DIP
Switch
Settings
SW01
Unused
SW02
ON
SW03
Unused
SW04
ON
SW05
OFF
SW06
ON
SW07
ON
SW08
OFF
Data bit setting
SW09
ON
Parity bit setting whether enable or disable
SW10
ON
Parity setting whether Even or Odd
SW11
ON
Stop bit setting
SW12
ON
Sum check setting whether enable or disable
Setup Description
Unused
Computer link/Multiple drop link selection
Unused
Write setting during RUN whether enable or
disable
Transmission speed setting
‹ Station Setting Rotary Switch
Rotary
Switch
Settings
X10
0
X1
0
Setup Description
Station No. setting
GP-Pro EX Device/PLC Connection Manual
23
A Series Computer Link Driver
3.8
Setting Example 8
„ Settings of GP-Pro EX
‹ Communication Settings
To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace.
‹ Device Setting
To display the setting screen, click
([Setting]) of External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
When you connect multiple External Device, click
from [Device-Specific Settings] of [Device/PLC
Settings] to add another External Device.
GP-Pro EX Device/PLC Connection Manual
24
A Series Computer Link Driver
„ Setting of External Device
Use the DIP switch of the Computer Link Unit for setting. Please refer to the manual of the External Device for
more details.
‹ Mode Setting Rotary Switch
Settings
8
Setup Description
Protocol mode in Form 4
‹ Communication Setting DIP Switch
DIP
Switch
Settings
SW10
ON
Computer link/Multiple drop link selection
SW11
ON
Main channel setting
SW12
ON
Write setting during RUN whether enable or
disable
SW13
OFF
SW14
ON
SW15
ON
SW16
OFF
Data bit setting
SW17
ON
Parity bit setting whether enable or disable
SW18
ON
Parity setting whether Even or Odd
SW19
ON
Stop bit setting
SW20
ON
Sum check setting whether enable or disable
Setup Description
Transmission speed setting
‹ Termination resistance DIP switch
DIP
Switch
Settings
SW21
OFF
SW22
Option
Termination resistance on the sending side
SW23
Option
Termination resistance on the receiving side
Setup Description
Unused
‹ Station Setting Rotary Switch
Rotary
Switch
Settings
X10
0
X1
0
Setup Description
Station No. setting
GP-Pro EX Device/PLC Connection Manual
25
A Series Computer Link Driver
4
Setup Items
Set communication settings of the Display with GP-Pro Ex or in off-line mode of the Display.
The setting of each parameter must be identical to that of External Device.
)"3 Example of Communication Setting" (page 10)
4.1
Setup Items in GP-Pro EX
„ Communication Settings
To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace.
Setup Items
Setup Description
SIO Type
Select the SIO type to communicate with the External Device.
Speed
Select speed between the External Device and the Display.
Data Length
Select data length.
Parity
Select how to check parity.
Stop Bit
Select stop bit length.
Flow Control
Select the communication control method to prevent overflow of transmission and
reception data.
Use an integer from 1 to 127 to enter the time (s) for which the Display waits for the
response from the External Device.
Timeout
• Set the value to 5 seconds or more when you communicate via network.
Retry
In case of no response from the External Device, use an integer from 0 to 255 to enter how
many times the Display retransmits the command.
Wait To Send
Use an integer from 0 to 255 to enter standby time (ms) for the Display from receiving
packets to transmitting next commands.
RI/VCC
You can switch RI/VCC of the 9th pin when you select RS232C for SIO type.
It is necessary to change RI/5V by changeover switch of IPC when connect with IPC.
Please refer to the manual of the IPC for more detail.
GP-Pro EX Device/PLC Connection Manual
26
A Series Computer Link Driver
„ Device Setting
To display the setting screen, click
([Setting]) of External Device you want to set from [Device-Specific
Settings] of [Device/PLC Settings].
When you connect multiple External Device, click
from [Device-Specific Settings] of [Device/PLC
Settings] to add another External Device.
Setup Items
Setup Description
Station No.
Enter a station number of the External Device, using 0 to 31.
PC No.
Set when you communicate via network. Use an integer from 0 to 64 to enter PC No. of the
External Device to communicate. If you do not communicate via network, enter 255.
GP-Pro EX Device/PLC Connection Manual
27
A Series Computer Link Driver
4.2
Setup Items in Off-Line Mode
• Refer to the Maintenance/Troubleshooting manual for information on how to enter off-line mode
or about the operation.
Cf.
Maintenance/Troubleshooting Manual "2.2 Off-line Mode"
• The number of the setup items to be displayed for 1 page in the off-line mode depends on the
Display in use. Please refer to the Reference manual for details.
„ Communication Settings
To display the setting screen, touch [Device/PLC Settings] from [Peripheral Settings] in off-line mode. Touch the
External Device you want to set from the displayed list.
Setup Items
Setup Description
Select the SIO type to communicate with the External Device.
SIO Type
To make the communication settings correctly, confirm the serial interface specifications of
Display unit for [SIO Type].
We cannot guarantee the operation if a communication type that the serial interface does not
support is specified.
For details concerning the serial interface specifications, refer to the manual for Display unit.
Speed
Select speed between the External Device and the Display.
Data Length
Select data length.
Parity
Select how to check parity.
Stop Bit
Select stop bit length.
Flow Control
Select the communication control method to prevent overflow of transmission and reception data.
Use an integer from 1 to 127 to enter the time (s) for which the Display waits for the response
from the External Device.
Timeout (s)
• Set the value to 5 seconds or more when you communicate via network.
Retry
In case of no response from the External Device, use an integer from 0 to 255 to enter how many
times the Display retransmits the command.
Wait To Send (ms)
Use an integer from 0 to 255 to enter standby time (ms) for the Display from receiving packets to
transmitting next commands.
GP-Pro EX Device/PLC Connection Manual
28
A Series Computer Link Driver
„ Device Setting
To display the setting screen, touch [Device/PLC Settings] from [Peripheral Settings]. Touch the External Device
you want to set from the displayed list, and touch [Device].
Setup Items
Setup Description
Device/PLC Name
Select the External Device for device setting. Device name is a title of External Device set
with GP-Pro EX.(Initial value [PLC1])
Station No.
Enter a station number of the External Device, using 0 to 31.
PC No.
Set when you communicate via network. Use an integer from 0 to 64 to enter PC No. of the
External Device to communicate. If you do not communicate via network, enter 255.
GP-Pro EX Device/PLC Connection Manual
29
A Series Computer Link Driver
„ Option
To display the setting screen, touch [Device/PLC Settings] from [Peripheral Settings]. Touch the External Device
you want to set from the displayed list, and touch [Option].
Setup Items
RI/VCC
Setup Description
You can switch RI/VCC of the 9th pin when you select RS232C for SIO type.
It is necessary to change RI/5V by changeover switch of IPC when connect with IPC.
Please refer to the manual of the IPC for more detail.
• GP-4100 series do not have the [Option] setting in the off-line mode.
GP-Pro EX Device/PLC Connection Manual
30
A Series Computer Link Driver
5
Cable Diagram
The cable diagram shown below may be different from the cable diagram recommended by Mitsubishi Electric
Corp. Please be assured there is no operational problem in applying the cable diagram shown in this manual.
•
The FG pin of the External Device body must be D-class grounded. Please refer to the manual of the External
•
SG and FG are connected inside the Display. When connecting SG to the External Device, design the system
Device for more details.
not to form short-circuit loop.
•
Connect the isolation unit, when communication is not stabilized under the influence of a noise etc..
Cable Diagram 1
Display
(Connection Port)
GP3000 (COM1)
ST (COM1)
IPC*1
PC/AT
GP-4105 (COM1)
*1
Cable
Notes
1A
RS232C cable by Pro-face
CA3-CBL232/5M-01 (5m)
1B
User-created cable
1C
User-created cable
The cable length must be 15m or
less.
Only the COM port which can communicate by RS-232C can be used.
„ IPC COM Port (page 7)
)
1A)
Display
External Device
CA3-CBL232/5M-01
RS232C
1B)
External Device side
D-sub 25 pin (plug)
Display side
D-sub 9 pin (socket)
Display
Pin
Signal name
2
Shield
Pin
Signal name
RD(RXD)
2
SD(TXD)
3
SD(TXD)
3
RD(RXD)
4
ER(DTR)
6
DSR(DR)
5
SG
7
SG
7
RS(RTS)
8
CD
8
CS(CTS)
20
DTR(ER)
5
CS(CTS)
1
FG
GP-Pro EX Device/PLC Connection Manual
31
A Series Computer Link Driver
1C)
External Device side
D-sub 25 pin (plug)
Display side
Terminal block
Signal name
Shield
Pin
Signal name
RD(RXD)
2
SD(TXD)
SD(TXD)
3
RD(RXD)
ER(DTR)
6
DSR(DR)
SG
7
SG
RS(RTS)
8
CD
CS(CTS)
20
DTR(ER)
5
CS(CTS)
1
FG
Display
GP-Pro EX Device/PLC Connection Manual
32
A Series Computer Link Driver
Cable Diagram 2
Display
(Connection Port)
GP3000*1 (COM1)
AGP-3302B (COM2)
ST*2 (COM2)
IPC*3
Cable
2A
COM port conversion adapter by Pro-face
CA3-ADPCOM-01
+
Terminal block conversion adapter
by Pro-face
CA3-ADPTRM-01
+
User-created cable
2B
User-created cable
2C
Online adapter by Pro-face
CA4-ADPONL-01
+
Terminal block conversion adapter
by Pro-face
CA3-ADPTRM-01
+
User-created cable
2D
Online adapter by Pro-face
CA4-ADPONL-01
+
User-created cable
2E
User-created cable
GP3000*4 (COM2)
GP-4106 (COM1)
*1
All GP3000 models except AGP-3302B
*2
All ST models except AST-3211A and AST-3302B
*3
Only the COM port which can communicate by RS-422/485 (4 wire) can be used.
„ IPC COM Port (page 7)
*4
All GP3000 models except GP-3200 series and AGP-3302B
Notes
The cable length must be
500m or less.
)
• In order to improve noise resistance characteristics, please use a twist pair whole shield cable as a
transmission cable and ground the shield line.
GP-Pro EX Device/PLC Connection Manual
33
A Series Computer Link Driver
2A)
•
1:1 Connection
External
Device side
Display side
Terminal block
Display
CA3-ADPCOM-01
Termination
resistance
330 1/4W
Termination
resistance
330 1/4W
Shield
Signal
name
Signal
name
RDA
SDA
RDB
SDB
SDA
RDA
SDB
RDB
SG
SG
CA3-ADPTRM-01
FG
User-created cable
•
1:n Connection
Display side
Display
CA3-ADPCOM-01
CA3-ADPTRM-01
Termination Terminal block
resistance
Signal
1/4W
name
Termination
resistance
1/4W
Shield
External
Device side
Signal
name
Shield
External
Device side
Signal
name
RDA
SDA
SDA
RDB
SDB
SDB
SDA
RDA
RDA
SDB
RDB
RDB
SG
SG
SG
FG
FG
User-created cable
• The termination resistance of 330Ω1/4W is required between SDA-SDB and RDARDB in the unit on the terminatory External Device.
• When the termination resistance is attached to the unit, you can turn ON the switch
to load the termination resistance. Please refer to the manual of the External Device
for more details.
GP-Pro EX Device/PLC Connection Manual
34
A Series Computer Link Driver
2B)
•
1:1 Connection
Display side
D-sub 9 pin (socket)
Termination
resistance
330 1/4W
Display
Termination
resistance
330 1/4W
•
Shield
External
Device side
Pin
Signal
name
Signal
name
1
RDA
SDA
2
RDB
SDB
3
SDA
RDA
7
SDB
RDB
5
SG
SG
4
ERA
FG
8
CSA
9
ERB
6
CSB
Shell
FG
1:n Connection
Display side
D-sub 9 pin (socket)
Termination
resistance
330 1/4W
Display
Termination
resistance
330 1/4W
Shield
External
Device side
Shield
External
Device side
Pin
Signal
name
Signal
name
Signal
name
1
RDA
SDA
SDA
2
RDB
SDB
SDB
3
SDA
RDA
RDA
7
SDB
RDB
RDB
5
SG
SG
SG
4
ERA
FG
FG
8
CSA
9
ERB
6
CSB
• The termination resistance of 330Ω1/4W is required between SDA-SDB and RDARDB in the unit on the terminatory External Device.
• When the termination resistance is attached to the unit, you can turn ON the switch
to load the termination resistance. Please refer to the manual of the External Device
for more details.
GP-Pro EX Device/PLC Connection Manual
35
A Series Computer Link Driver
2C)
•
1:1 Connection
CA4-ADPONL-01
Display
CA3-ADPTRM-01
Termination
resistance
330 1/4W
Display side
Terminal block
Termination
resistance
330 1/4W
External
Device side
Shield
Signal
name
Signal
name
RDA
SDA
RDB
SDB
SDA
RDA
SDB
RDB
SG
SG
FG
User-created cable
•
1:n Connection
Display
Termination
resistance
CA4-ADPONL-01 330 1/4W
CA3-ADPTRM-01
Termination
resistance
330 1/4W
Display side
Terminal block
Shield
External
Device side
Shield
External
Device side
Signal
name
Signal
name
Signal
name
RDA
SDA
SDA
SDA
RDB
SDB
SDB
SDB
SDA
RDA
RDA
RDA
SDB
RDB
RDB
RDB
SG
SG
SG
SG
FG
FG
FG
User-created cable
• The termination resistance of 330Ω1/4W is required between SDA-SDB and RDARDB in the unit on the terminatory External Device.
• When the termination resistance is attached to the unit, you can turn ON the switch
to load the termination resistance. Please refer to the manual of the External Device
for more details.
GP-Pro EX Device/PLC Connection Manual
36
A Series Computer Link Driver
2D)
•
1:1 Connection
Termination
resistance
330 1/4W
Display
CA4-ADPONL-01
Termination
resistance
330 1/4W
Display side
D-sub 9 pin (plug)
Shield
External
Device side
Pin
Signal
name
Signal
name
2
RDA
SDA
7
RDB
SDB
3
SDA
RDA
8
SDB
RDB
5
SG
SG
Shell
FG
FG
User-created cable
•
1:n Connection
Display side
Display
CA4-ADPONL-01
Termination D-sub 9 pin (plug)
resistance
Signal
Pin
name
330 1/4W
Termination
resistance
330 1/4W
Shield
External
Device side
Shield
External
Device side
Signal
name
Signal
name
SDA
2
RDA
SDA
7
RDB
SDB
SDB
3
SDA
RDA
RDA
8
SDB
RDB
RDB
5
SG
SG
SG
Shell
FG
FG
FG
User-created cable
• The termination resistance of 330Ω1/4W is required between SDA-SDB and RDARDB in the unit on the terminatory External Device.
• When the termination resistance is attached to the unit, you can turn ON the switch
to load the termination resistance. Please refer to the manual of the External Device
for more details.
GP-Pro EX Device/PLC Connection Manual
37
A Series Computer Link Driver
2E)
•
1:1 Connection
Display side
Terminal block
Termination
resistance*1
Shield
External
Device side
Signal
name
Signal
name
RDA
SDA
Termination
Display resistance*1
RDB
SDB
SDA
RDA
SDB
RDB
SG
SG
ERA
FG
CSA
ERB
CSB
•
1:n Connection
Termination
resistance*1
Display
Termination
resistance*1
Display side
Terminal block
Signal
name
Shield
RDA
External
Device side
Shield
External
Device side
Signal
name
Signal
name
SDA
SDA
RDB
SDB
SDB
SDA
RDA
RDA
SDB
RDB
RDB
SG
SG
SG
ERA
FG
FG
CSA
ERB
CSB
• The termination resistance of 330Ω1/4W is required between SDA-SDB and RDARDB in the unit on the terminatory External Device.
• When the termination resistance is attached to the unit, you can turn ON the switch
to load the termination resistance. Please refer to the manual of the External Device
for more details.
*1
The resistance in the Display is used as the termination resistance. Set the value of the DIP Switch on the
rear of the Display as shown in the table below.
DIP Switch No.
Set Value
1
ON
2
OFF
3
ON
4
OFF
GP-Pro EX Device/PLC Connection Manual
38
A Series Computer Link Driver
Cable Diagram 3
Display
(Connection Port)
GP3000 (COM1)
ST (COM1)
IPC*1
PC/AT
GP-4105 (COM1)
*1
Cable
Notes
3A
Mitsubishi Q link cable by Pro-face
CA3-CBLLNKMQ-01 (5m)
3B
User-created cable
3C
User-created cable
The cable length must be
15m or less.
Only the COM port which can communicate by RS-232C can be used.
„ IPC COM Port (page 7)
)
3A)
Display
External Device
CA3-CBLLNKMQ-01
RS232C
3B)
Display side
External Device side
D-sub 9 pin (plug)
D-sub 9 pin (socket)
Shield
Display
Pin
Signal name
Pin
Signal name
2
RD(RXD)
3
SD(TXD)
3
SD(TXD)
2
RD(RXD)
4
ER(DTR)
6
DSR(DR)
5
SG
5
SG
7
RS(RTS)
1
CD
8
CS(CTS)
4
DTR(ER)
8
CS(CTS)
Shell
FG
GP-Pro EX Device/PLC Connection Manual
39
A Series Computer Link Driver
3C)
External Device side
D-sub 9 pin (plug)
Display side
Terminal block
Shield
Display
Signal name
Pin
Signal name
RD(RXD)
3
SD(TXD)
SD(TXD)
2
RD(RXD)
ER(DTR)
6
DSR(DR)
SG
5
SG
RS(RTS)
1
CD
CS(CTS)
4
DTR(ER)
8
CS(CTS)
Shell
FG
GP-Pro EX Device/PLC Connection Manual
40
A Series Computer Link Driver
Cable Diagram 4
Display
(Connection Port)
Cable
4A
COM port conversion adapter by Pro-face
CA3-ADPCOM-01
+
Connector terminal block conversion adapter
by Pro-face
CA3-ADPTRM-01
+
User-created cable
4B
COM port conversion adapter by Pro-face
CA3-ADPCOM-01
+
Multilink cable by Pro-face
CA3-CBLMLT-01
+
User-created cable
4C
User-created cable
4D
Online adapter by Pro-face
CA4-ADPONL-01
+
Connector terminal block conversion adapter
by Pro-face
CA3-ADPTRM-01
+
User-created cable
4E
Online adapter by Pro-face
CA4-ADPONL-01
+
Multilink cable by Pro-face
CA3-CBLMLT-01
+
User-created cable
4F
Online adapter by Pro-face
CA4-ADPONL-01
+
User-created cable
4G
User-created cable
GP3000*1 (COM1)
AGP-3302B (COM2)
ST *2 (COM2)
IPC*3
GP3000 *4 (COM2)
GP-4106 (COM1)
*1
All GP3000 models except AGP-3302B
*2
All ST models except AST-3211A and AST-3302B
*3
*4
Only the COM port which can communicate by RS-422/485 (4 wire) can be used.
)„ IPC COM Port (page 7)
All GP3000 models except GP-3200 series and AGP-3302B
GP-Pro EX Device/PLC Connection Manual
41
Notes
The cable length must be
500m or less.
A Series Computer Link Driver
4A)
Display side
Terminal block
Termination
resistance
Signal name
330 1/4W
Termination
resistance
330 1/4W
Shield
Display side
Terminal block
Shield
External Device side
Terminal block
Signal name
Signal name
RDA
RDA
SDA
RDB
RDB
SDB
SDA
SDA
RDA
SDB
SDB
RDB
SG
SG
SG
FG
FG
FG
CA3-ADPTRM-01
CA3-ADPTRM-01
CA3-ADPCOM-01
CA3-ADPCOM-01
Display
Display
User-created cable
• The termination resistance of 330Ω1/4W is required between SDA-SDB and RDARDB in the unit on the terminatory External Device.
• When the termination resistance is attached to the unit, you can turn ON the switch
to load the termination resistance. Please refer to the manual of the External Device
for more details.
GP-Pro EX Device/PLC Connection Manual
42
A Series Computer Link Driver
4B)
Display side
Terminal block
(M3 screw)
Termination
resistance
330 1/4W
Termination
resistance
330 1/4W
Display side
Terminal block
(M3 screw)
Shield
Shield
External Device side
Terminal block
Signal name
Signal name
Signal name
RDA
RDA
SDA
RDB
RDB
SDB
SDA
SDA
RDA
SDB
SDB
RDB
SG
SG
SG
FG
FG
FG
CA3-CBLMLT-01
CA3-CBLMLT-01
CA3-ADPCOM-01
CA3-ADPCOM-01
Display
Display
User-created cable
• The termination resistance of 330Ω1/4W is required between SDA-SDB and RDARDB in the unit on the terminatory External Device.
• When the termination resistance is attached to the unit, you can turn ON the switch
to load the termination resistance. Please refer to the manual of the External Device
for more details.
GP-Pro EX Device/PLC Connection Manual
43
A Series Computer Link Driver
4C)
Display side
D-sub 9 pin (socket)
Termination
resistance
330 1/4W
Termination
resistance
330 1/4W
Display
Terminal block
(M3 screw)
Shield
Shield
Terminal block
(M3 screw)
Shield
External Device side
Terminal block
Pin
Signal name
Signal name
Signal name
Signal name
1
RDA
RDA
SDA
2
RDA
RDB
RDB
RDB
SDB
3
7
SDA
SDB
SDA
SDA
RDA
SDB
SDB
RDB
5
SG
ERA
SG
SG
SG
FG
FG
FG
4
8
9
CSA
6
CSB
Shell
FG
ERB
Display side
D-sub 9 pin (socket)
Shield
Pin
Signal name
Signal name
1
RDA
RDA
2
RDB
RDB
3
7
SDA
SDA
SDB
SDB
5
SG
ERA
SG
Display
4
FG
CSA
8
9
ERB
6
CSB
• The termination resistance of 330Ω1/4W is required between SDA-SDB and RDARDB in the unit on the terminatory External Device.
• When the termination resistance is attached to the unit, you can turn ON the switch
to load the termination resistance. Please refer to the manual of the External Device
for more details.
GP-Pro EX Device/PLC Connection Manual
44
A Series Computer Link Driver
4D)
Display side
Terminal block
Termination
resistance
330 1/4W
Termination
resistance
330 1/4W
Display side
Terminal block
Shield
Shield
External Device side
Terminal block
Signal name
Signal name
Signal name
RDA
RDA
SDA
RDB
RDB
SDB
SDA
SDA
RDA
SDB
SDB
RDB
SG
SG
SG
FG
FG
FG
CA3-ADPTRM-01
CA3-ADPTRM-01
CA4-ADPONL-01
CA4-ADPONL-01
Display
Display
User-created cable
• The termination resistance of 330Ω1/4W is required between SDA-SDB and RDARDB in the unit on the terminatory External Device.
• When the termination resistance is attached to the unit, you can turn ON the switch
to load the termination resistance. Please refer to the manual of the External Device
for more details.
GP-Pro EX Device/PLC Connection Manual
45
A Series Computer Link Driver
4E)
Display side
Terminal block
(M3 screw)
Termination
resistance
330 1/4W
Termination
resistance
330 1/4W
Display side
Terminal block
(M3 screw)
Shield
Shield
External Device side
Terminal block
Signal name
Signal name
Signal name
RDA
RDA
SDA
RDB
RDB
SDB
SDA
SDA
RDA
SDB
SDB
RDB
SG
SG
SG
FG
FG
FG
CA3-CBLMLT-01
CA3-CBLMLT-01
CA4-ADPONL-01
CA4-ADPONL-01
Display
Display
User-created cable
• The termination resistance of 330Ω1/4W is required between SDA-SDB and RDARDB in the unit on the terminatory External Device.
• When the termination resistance is attached to the unit, you can turn ON the switch
to load the termination resistance. Please refer to the manual of the External Device
for more details.
GP-Pro EX Device/PLC Connection Manual
46
A Series Computer Link Driver
4F)
Display
Termination
resistance
330 1/4W
CA4-ADPONL-01
Termination
resistance
330 1/4W
Display side
D-sub 9 pin (plug)
Terminal block
(M3 screw)
Shield
Shield
Terminal block
(M3 screw)
Shield
External Device side
Terminal block
Pin
Signal
name
Signal name
Signal name
Signal name
2
RDA
RDA
RDA
SDA
7
RDB
RDB
RDB
SDB
3
SDA
SDA
SDA
RDA
8
SDB
SDB
SDB
RDB
5
SG
SG
SG
SG
Shell
FG
FG
FG
FG
Display side
D-sub 9 pin (plug)
Display
CA4-ADPONL-01
Shield
Pin
Signal
name
Signal name
2
RDA
RDA
7
RDB
RDB
3
SDA
SDA
8
SDB
SDB
5
SG
SG
Shell
FG
FG
• The termination resistance of 330Ω1/4W is required between SDA-SDB and RDARDB in the unit on the terminatory External Device.
• When the termination resistance is attached to the unit, you can turn ON the switch
to load the termination resistance. Please refer to the manual of the External Device
for more details.
GP-Pro EX Device/PLC Connection Manual
47
A Series Computer Link Driver
4G)
Display side
Terminal block
Termination
resistance*1
Termination
resistance*1
Shield
Display side
Terminal block
Shield
External Device side
Terminal block
Signal name
Signal name
Signal name
RDA
RDB
RDA
SDA
RDB
SDB
SDA
SDB
SDA
RDA
SDB
RDB
SG
ERA
SG
ERA
SG
CSA
CSA
ERB
ERB
CSB
CSB
Display
FG
Display
• The termination resistance of 330Ω1/4W is required between SDA-SDB and RDARDB in the unit on the terminatory External Device.
• When the termination resistance is attached to the unit, you can turn ON the switch
to load the termination resistance. Please refer to the manual of the External Device
for more details.
*1
The resistance in the Display is used as the termination resistance. Set the value of the DIP Switch on the
rear of the Display as shown in the table below.
DIP Switch No.
Set Value
1
ON
2
OFF
3
ON
4
OFF
For the Displays other than that used as the terminal, set the DIP Switch 1-4 on the rear of the Display to
OFF in the n:1 connection.
GP-Pro EX Device/PLC Connection Manual
48
A Series Computer Link Driver
6
Supported Device
Range of supported device address is shown in the table below. Please note that the actually supported range of
the devices varies depending on the External Device to be used. Please check the actual range in the manual of
your External Device.
6.1
MELSEC AnA Series, Q Series A Mode
This address can be specified as system data area.
Device
Bit Address
Word Address
Input
X00000 - X01FFF
(X007FF*1)
X00000 - X01FF0
(X007F0*1)
Output
Y00000 - Y01FFF
(Y007FF*1)
Y00000 - Y01FF0
(Y007F0*1)
Internal Relay
M0000 - M8191
M0000 - M8176
Latch Relay
L000000 - L008191
L000000 - L008176
Step Relay
S000000 - S008191
S000000 - S008176
Link Relay
Annunciator
B00000 - B01FFF
(B00FFF*1)
F000000 - F002032
M9000 - M9255
M9000 - M9240
Timer (Contact)
TS00000 - TS02047
------
Timer (Coil)
TC00000 - TC02047
------
Counter (Contact)
CS00000 - CS01023
------
Counter (Coil)
CC00000 - CC01023
------
Timer (Current Value)
------
TN00000 - TN02047
Counter (Current Value)
------
CN00000 - CN01023
Data Register
------
D00000 - D08191
(D06143*1)
Link Register
------
W0000 - W1FFF
(W0FFF*1)
File Register
------
R00000 - R08191
Extension File Register
------
0R0000 - 0R8191
:
64R0000 - 64R8191
Special Register*2
------
D09000 - D09255
*1
Notes
B00000 - B01FF0
(B00FF0*1)
F000000 - F002047
Special Relay
32bits
Shows the maximum device number that can be specified in the computer link unit except AJ71UC24,
A1SJ71UC24 - R2/R4/PRF.
GP-Pro EX Device/PLC Connection Manual
49
A Series Computer Link Driver
*2
Divided into 3 areas, for read only, for write only, for the system. When you write outside the write enable range,
CPU error of the External Device may occur.
• Please refer to the GP-Pro EX Reference Manual for system data area.
Cf. GP-Pro EX Reference Manual "Appendix 1.4 LS Area (Direct Access Method)"
• Please refer to the precautions on manual notation for icons in the table.
) "Manual Symbols and Terminology"
GP-Pro EX Device/PLC Connection Manual
50
A Series Computer Link Driver
6.2
MELSEC AnN Series
This address can be specified as system data area.
Device
Bit Address
Word Address
Input
X00000 - X007FF
X00000 - X007F0
Output
Y00000 - Y007FF
Y00000 - Y007F0
M0000 - M2047
M0000 - M2032
Latch Relay
L000000 - L002047
L000000 - L002032
Step Relay
S000000 - S002047
S000000 - S002032
Link Relay
B00000 - B003FF
B00000 - B003F0
F000000 - F000255
F000000 - F000240
M9000 - M9255
M9000 - M9240
Timer (Contact)
TS00000 - TS00255
------
Timer (Coil)
TC00000 - TC00255
------
Counter (Contact)
CS00000 - CS00255
------
Counter (Coil)
CC00000 - CC00255
------
Timer (Current Value)
------
TN00000 - TN00255
Counter (Current Value)
------
CN00000 - CN00255
Data Register
------
D00000 - D01023
Link Register
------
W0000 - W03FF
File Register
------
R00000 - R08191
Extension File Register
------
0R0000 - 0R8191
:
28R0000 - 28R8191
Special Register*1
------
D09000 - D09255
Internal Relay
Annunciator
Special Relay
*1
32bits
Notes
Divided into 3 areas, for read only, for write only, for the system. When you write outside the write enable range,
CPU error of the External Device may occur.
• Please refer to the GP-Pro EX Reference Manual for system data area.
Cf. GP-Pro EX Reference Manual "Appendix 1.4 LS Area (Direct Access Method)"
• Please refer to the precautions on manual notation for icons in the table.
) "Manual Symbols and Terminology"
GP-Pro EX Device/PLC Connection Manual
51
A Series Computer Link Driver
6.3
MELSEC QnA Series
This address can be specified as system data area.
Device
Bit Address
Word Address
Input Relay
X0000 - X07FF
X0000 - X07F0
Output Relay
Y0000 - Y07FF
Y0000 - Y07F0
Internal Relay
M0000 - M8191
M0000 - M8176
Special Relay
M9000 - M9255
(SM1000 - SM1255)
M9000 - M9240
(SM1000 - SM1240)
Annunciator
F00000 - F02047
F00000 - F02047
Link Relay
B00000 - B00FFF
B00000 - B00FF0
Timer (Contact)
TS00000 - TS02047
------
Timer (Coil)
TC00000 - TC02047
------
Counter (Contact)
CS00000 - CS01023
------
Counter (Coil)
CC00000 - CC01023
------
Timer (Current Value)
------
TN00000 - TN02047
Counter (Current Value)
------
CN00000 - CN01023
Data Register
------
D000000 - D006143
Special Register
------
D009000 - D009255
(SD1000 - SD1255)
Link Register
------
W0000 - W0FFF
32bits
Notes
• Please refer to the GP-Pro EX Reference Manual for system data area.
Cf. GP-Pro EX Reference Manual "Appendix 1.4 LS Area (Direct Access Method)"
• Please refer to the precautions on manual notation for icons in the table.
) "Manual Symbols and Terminology"
GP-Pro EX Device/PLC Connection Manual
52
A Series Computer Link Driver
7
Device Code and Address Code
Use device code and address code when you select "Device Type & Address" for the address type in data displays.
Device Name
Device Code
(HEX)
Address Code
Input
X
0080
Value of word address divided by 0x10
Output
Y
0081
Value of word address divided by 0x10
Internal Relay
M
(0000 - 8991)
0082
Value of word address divided by 16
Special Relay
M
(9000 - 9991)
0083
Value of (word address - 9000) divided
by 16
Latch Relay
L
0084
Value of word address divided by 16
Step Relay
S
0087
Value of word address divided by 16
Link Relay
B
0088
Value of word address divided by 0x10
Annunciator
F
0085
Value of word address divided by 16
Timer (Current Value)
TN
0060
Word Address
Counter (Current Value)
CN
0061
Word Address
Data Register
Special Register
D
0000
Word Address
Link Register
W
0002
Word Address
File Register
R
000F
Word Address
0R
0010
Word Address
:
:
31R
002F
:
:
64R
0050
Device
Extension File Register
GP-Pro EX Device/PLC Connection Manual
53
:
Word Address
:
Word Address
A Series Computer Link Driver
8
Error Messages
Error messages are displayed on the Display screen as follows: "No.: Device Name: Error Message (Error
Occurrence Area)". Each description is shown below.
Item
Description
No.
Error No.
Device Name
Name of the External Device where error occurs. Device name is a title of the External
Device set with GP-Pro EX. (Initial value [PLC1])
Error Message
Displays messages related to the error which occurs.
Displays IP address or device address of the External Device where error occurs, or error
codes received from the External Device.
Error Occurrence Area
• IP address is displayed such as "IP address(Decimal): MAC address( Hex)".
• Device address is diplayed such as "Address: Device address".
• Received error codes are displayed such as "Decimal[Hex]".
Display Examples of Error Messages
"RHAA035: PLC1: Error has been responded for device write command (Error Code: 2 [02H])"
• Refer to your External Device manual for details on received error codes.
• Refer to "When an error is displayed (Error Code List)" in "Maintenance/Troubleshooting Manual"
for details on the error messages common to the driver.
GP-Pro EX Device/PLC Connection Manual
54