Carrier | SINGLE PACKAGED ELECTRIC COOLING UNITS 50GX | 50GS 018-060 STANDARD EFFICIENCY 50GX 024

50GS,GX-1SB
50GS 018-060
STANDARD EFFICIENCY
50GX 024-060
HIGH EFFICIENCY
SINGLE-PACKAGE
ELECTRIC COOLING UNITS
with optional ELECTRIC HEAT
— PERFORMANCE DATA
— CERTIFIED DIMENSION PRINT
— CERTIFIED ROOF CURB
DIMENSION PRINT
© 2001 Carrier Corporation
Form 50GS,GX-1SB New
Printed in U.S.A.
3-01
Catalog No. 515-001
Date:
50GS018-060/50GX024-060
Single-Package
Electric Cooling Units
Supersedes:
JOB DATA:
LOCATION:
BUYER:
BUYER P.O. #
UNIT NUMBER:
MODEL NUMBER:
UIP M E NT
STA
NDARD
21
0
5
EQ
RI
2
UNIT
AR
NING
ITIO
ND
A
Y
A2
CARRIER #
50GS/50GX units are self-contained, electric cooling units designed for easy installation and maintenance and dependable
performance. All units have discharge openings for either horizontal or downflow configuration, and all have low sound
levels. Units are intended for outdoor installation and may be
located on a rooftop, or a ground-level concrete slab, or directly on the ground if local codes permit.
T
IFIED O ARI A
RT
S
C
CE
AIR
CO
Rev.:
DATE:
YING WITH
PL
OM
MANUFACTUR
ER
PERFORMANCE DATA CERTIFIED BY:
50GS/50GX
3
FEATURES
• Standard one year limited warranty for both 50GS and
50GX.
• 10 year warranty on the 50GX compressor.
• 5 year warranty on the 50GS compressor.
• Units certified and listed by UL and c-UL. Units are rated
in accordance with ARI Standard 210.
• Low sound ratings.
• Units are pre-wired, pre-piped, and pre-charged for minimum installation expense.
• 12 SEER cooling efficiency, on 50GX; with Energy Star®
Recognition.
• Compressor vibration isolation provides quieter operation.
• Easily converted for downflow operation with included
horizontal duct covers.
• Cabinets are constructed of heavy-duty, phosphated, zinc
coated pre-painted steel capable of withstanding 500 hours in
salt spray.
• Easy-to-service cabinets with single-panel accessibility.
• Direct-drive multi-speed, permanent split capacitor (PSC)
indoor motor is standard.
• Direct-drive, PSC outdoor fan motor.
• Coils constructed of aluminum fins bonded to copper
tubes.
• Wire grille provides additional protection for the coil.
• Envirotuff™ composite rust-proof unit base pan.
• Sloped drain pan minimizes standing water in the unit.
• Refrigerant service connections make checking operating
pressures easier.
• Copper & pre-coated fin coils are available from the factory by special order, for use in corrosive environments.
• Three-phase units available.
PERFORMANCE DATA
Unit Operating Weight________lb (unit); ________lb
(curb)
COOLING
Net Total Capacity ____________________________ Btuh
Net Sensible Capacity _________________________ Btuh
Compressor Power Input__________kW @ _________ °F
Outdoor-Air Temperature
Indoor Entering-Air db__________°F wb _________ °F
Seasonal Energy Efficiency Ratio ____________________
CFM ___________ Ext. Static Pressure___________in. wg
Indoor Fan Motor _______ Hp________ Rpm________Bhp
2
HEATING
Power Input To Unit____________________________ kW
Indoor Operating Temp ________________________°F db
Outdoor-Air Temp ________________ °F (Winter Design)
Electric Capacity Required _____________________ Btuh
_______ KW Heater Selected
ELECTRICAL DATA
Unit Power Supply______Volts______Phase______ Hz
Minimum Circuit Amps______Maximum Overcurrent Protection______
FIELD-INSTALLED ACCESSORIES
Economizer
Manual Air Damper
Filter Rack
Flat Roof Curb:
8 in. Height
14 in. Height
Thermostat
Programmable
Non-Programmable
Crankcase Heater
Compressor Hard Start Kit
0°F Low Ambient Kit
Square-to-Round Duct Transition Kit
Electric Heat Package-5-20KW
Controls Upgrade Kit
TimeGuard® II Device
NOTES: ______________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
3
4
Cut along dotted line
CERTIFIED DIMENSION PRINT
C01010
5
CERTIFIED DIMENSION PRINT
Cut along dotted line
C01011
6
Return opening
(11" X 16 1/2" clear)
DRAWN BY: A.L.L.
JOB NAME:
EQUIPMENT:
NOTES:
SUBMITTED TO
COMPANY:
SUBMITTAL
44 5/16"
17 3/8"
Insulated
deck pan
Cut along dotted line
11"
28 3/4"
1"
R/A duct
*10 3/4"
Wood Nailer
Gasketing
* Duct size
14"
CPCRFCURB007A00
A
8"
CPCRFCURB006A00
Supply opening
(11" X 16 1/2" clear)
A
ODS Catalog Ordering No.
SIDE VIEW
1"
44 5/16"
3"
S/A duct
*10 3/4"
Support
HVAC unit
base pan
Gasketing
Feature:
• Constructed of heavy gage galvanized steel.
• Roofcurb ships knocked down in corrugated
box.
• Quick-clip design for easy field assembly.
• Insulated deck pan.
• Gasketing package and hardware included.
• Wood nailer provided.
Roof Curb for Small Cabinet
CERTIFIED DIMENSION PRINT
C00077
1"
7
Side View
Constructed of heavy gage galyanized steel.
Quick-clip design for easy field assembly.
Ships knocked down w/corrugated box.
Gasket package for complete outer perimeter
flange and around duct openings.
• Wood nailer provided.
•
•
•
•
FEATURES:
SUBMITTED TO:
COMPANY:
DRAWN BY: M. HARGIS
JOB NAME:
EQUIPMENT:
NOTES:
SUBMITTAL
Gasketing
40 5/16"
8"
14"
CPRFCURB009A00
A
17 3/8"
CPRFCURB008A00
ODS Catalog Ordering No.
16 3/16"
16 3/16"
Roof Curb for Large Cabinet
CERTIFIED DIMENSION PRINT
Cut along dotted line
C00078
Deck pan (insulated)
44 7/16"
A
Carrier Corporation • Indianapolis, IN 46231
3-01
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book
1
Tab
5a 5a
4
Page 8
Catalog No. 515-001
Printed in U.S.A.
PC 101
Form 50GS, GX-1SB
Replaces: New