The Link Search setup screen is used to set the length of time that the

Pinger Plus will monitor a wire pair for Link signals. Normal (about 2.5

seconds) is the default setting or use the Up/Down cursor key to select the

Long setting (about 5 seconds). Some switches, especially if configured for

VoIP, require a longer time to complete Link negotiations and the Long setting will provide more consistent Link detection.

UPD A TE PINGER SCREEN

The Pinger Plus firmware can be updated over the network as new revisions are released. Notice of a new revision will be provided on the

Psiber web site (www.psiber.com). Download the new firmware file, connect the Pinger Plus to the network, go to the Update Pinger Setup screen, press the Select function key and the unit will Link to the network and enable the firmware update mode. Next run the downloaded file on the computer. The program will ask for the current IP address of the Pinger Plus (see Pinger IP

Address Setup screen) and your password. When the update is complete the program will notify the user and the Pinger Plus immediately goes to the

Link screen and searches for the Link. WARNING: Any disruption while programming is in process will result in the unit being unuseable and will have to be returned to the factory for repair. Install a fresh set of batteries or connect the AC adapter to the unit before starting an update.

PO WER

Duration The Pinger Plus will typically provide about 5 to 6 hours of operation from a set of four AA alkaline batteries. An AC adapter is also provided which will power the unit but does not recharge the batteries.

Auto Power Down The Pinger will automatically turn off after the time selected in the Power Down Setup screen or will run continuously until manually turned off when “ON” is selected for Power Down.

Low Battery - When the batteries are below the level required for the Pinger

Plus to operate properly, a battery graphic appears in the upper right hand corner of the display.

P INGER P

+

TM

NETW ORK IP TESTER

Psiber Data Systems Inc. warrants that the product shall be free from defects in parts or workmanship for a period of 12 months from the date of purchase if used in accordance with Psiber Data Systems Inc. operating specifications.

THIS IS THE ONLY WARRANTY MADE BY Psiber Data Systems Inc. AND IS EXPRESSLY MADE IN LIEU

OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED

WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.

Should any parts or workmanship prove defective, Psiber Data Systems Inc. will repair or replace at Psiber Data

Systems’ option, at no cost to the Buyer except for shipping costs from the Buyer’s location to Psiber Data Systems Inc.

This is Buyer’s SOLE AND EXCLUSIVE REMEDY under this Agreement.

This warranty does not apply to products which have been subject to neglect, accident or improper use, or to units which have been altered or repaired by other than an authorized repair facility.

Return of Equipment - To return a product to Psiber Data Systems Inc., first obtain a Return Authorization number from our Customer Service by calling 619-287-9970. The RA# must be clearly marked on the shipping label, or the package will not be accepted by Psiber Data Systems Inc. See sample label below.

To: Psiber Data Sytems Inc.

7075-K Mission Gorge Road

San Diego, CA 92120

RA# XXXXXXXX

Pinger, Plus + , psiber and the Psiber logo are trademarks of Psiber Data Systems Inc.

Copyright 2003 Psiber Data Systems Inc. All rights reserved.

P/N 1005-0650-0000 Rev. D

BO X CONTENTS

Pinger Plus Network IP Tester

AC Adapter

Four AA Alkaline Batteries

User Guide

B A TTER Y

The Pinger Plus operates on four AA alkaline batteries. Remove the battery cover at the back of the unit and insert the batteries with the orientation as shown. Battery polarity is marked inside the battery well for reference.

TECHNICAL O VER VIEW

The Pinger Plus Network IP Tester uses the “PING” function to send a data packet to another IP address on a network or respond to a PING sent to its own IP address. The PING test is used to verify connectivity, measure round trip communications time, check data integrity, determine a MAC address and search a stored list or a range of IP addresses. The Pinger Plus provides a DHCP Client mode and a Port Identification function with selectable blink rates to locate which port on a hub or switch that a wall outlet is connected.

NETW ORK COMP A TIBILITY

The Pinger Plus is designed for testing an Ethernet network that uses the IP protocol. The unit can communicate directly with a hub, switch, router,

NIC or other network device that uses 10baseT or 100baseT. The Pinger

Plus will identify when it is connected to a 1000baseT device but it cannot transmit/receive a PING at 1000baseT.

MECHANICAL FEA TURES

WEB BRO WSER INTERF A

The Pinger Plus can be configured by connecting it to the network and using either Internet Explorer (6.0 or later) or Netscape (6.0 or later). To access the Pinger Plus setup page, enter the Pinger IP address (shown in the Pinger IP Address setup screen) in the browser URL window. All setup features can be configured from the browser. The User Guide can also be displayed.

PINGER IP SETUP SCREEN

The IP address for the Pinger Plus is input from this screen. The unit comes programmed with a default address of 192.168.1.42.

SUBNET MASK SETUP SCREEN

To Ping an IP address in a subnet different than the subnet of the

Pinger Plus, requires that the Subnet Mask be entered and “ON” and the appropriate Gateway IP address has been entered. Mask “ON” and

OFF” is selected with the Up/Down Cursor key. A zero in the first field is an invalid mask entry and the Pinger defaults to 255 when the mask is saved.

NOTE: Subnet Mask and Default Gateway IP address may be found by going to a computer on the subnet where the Pinger Plus will be used, open the Windows Control Panel, open the network icon, open the LAN icon, select TCP/IP Protocol and then select properties.

G A TEWA Y SETUP SCREEN

The IP address for the default Gateway (typically a router or a server) is input from this screen.

PINGER MA C SCREEN

The Pinger Plus MAC address is displayed in this screen. The MAC for each Pinger is unique and can not be changed. See Note in DHCP.

PROFILE SETUP SCREEN

A profile consists of a Profile name, Pinger Plus IP address, Subnet

Mask on or off, Subnet Mask, Gateway Address and a list of one to eight destination IP addresses. One of the eight Profiles is selected using the Up/

Down cursor, the Profile name and Pinger Plus IP address is entered and the

Next function key is pressed. The Subnet Mask is entered and turned on or off and the Next fuction key is pressed. The Gateway address is entered and the Next function key is pressed. From one to eight destination IP addresses are entered and then the Save function key is pressed.

DEF A UL T PROFILE SCREEN

A default profile can be designated to be used initially when the Pinger

Plus is powered on.

WER DO WN SETUP SCREEN

The Pinger Plus will automatically turn off after the time selected in the

Power Down Setup screen. Settings available are five minutes, fifteen minutes, thirty minutes and on (must be turned off manually). Press the

SAVE function key to store the selected setting.

P ASSW ORD SCREEN

A password is required to configure the Pinger Plus from a web browser or update the firmware. The password protects against a third party making unauthorized changes to the unit when it is connected to a network. The default password is 12345678. It is recommended that the default password be changed prior to initial operation.

PING COUNT SETUP SCREEN

The Pinger Plus can be set to PING an IP address from 1 to 99 times or continuously. Pressing the Up/Down cursor key scrolls the number of times to

PING from 1 to 99. The Continuous PING setting is shown by scrolling down from “1” or up from “99”. Multiple PINGs are not available for Lists, Profiles or

Ranges.

PING P A CKET SIZE AND TIMEOUT SETUP SCREENS

The PING packet size has six settings from 50 to 1400 bytes. The time the Pinger Plus waits for a PING or DHCP response before displaying a No

Response notice can be set from 1 to 40 seconds in one second increments.

POR T ID SCREEN

Pressing the PortID function key in the Link Screen presents the Port ID

Screen. As soon as this screen appears, the Pinger begins transmitting a pattern of Link signals that will cause the hub,switch or NIC Link LED to blink or stay on continuously. Identifying the specific port a wall outlet/PC is connected to can aid in diagnosing the cause of failed PING tests. Hubs and switches from various manufacturers have different specifications for the time it takes for Link signals to turn the Link

LED on and off. The Pinger Plus has four different blink rates and a continuous mode that can be selected by pressing the Up/Down cursor key.

An initial test directly at the hub or switch will determine the best blink rate setting before conducting a

Port ID test at a wall outlet.

SETUP

Pressing the SETUP key in any screen presents the Setup Screen.The

Up/Down cursor key is used to display: 1) Pinger IP Address Setup 2) Pinger

Subnet Mask Setup 3) Pinger Gateway

Setup 4) Pinger IP List Setup 5) Pinger

MAC Screen 6) Profile Setup 7) Default

Profile 8) Ping Count 9) Packet Size

10)Time Out 11) Power Down Time

Setup 12) Password Setup or 13) Pinger Update . Press the SELECT function key to enter the displayed setup screen. The Pinger MAC is shown for information only and can not be changed.

IP LIST SETUP SCREEN

The IP List Setup screen is used to enter from one to eight names and IP addresses. The Pinger can then PING the entries individually or PING all entries sequentially.

Data Entry - Use the Up/Down cursor key to select one of the eight storage locations and press the right arrow key to display the cursor and begin entering a new name or editing an existing one. Use the data entry keypad to input the number or letter (each time the key is pressed the next letter or number on the key is displayed). Pressing the right cursor key advances to the next character. Pressing the left cursor key selects the previous character. Names can be a maximum of ten characters long. Pressing the right cursor key an eleventh time advances the cursor to the IP Address which is divided into four fields of three characters. Only numbers can be input in the fields and the maximum valid number for any field is 255. Single digits can be entered in any of the three character locations and will be right hand justified when the cursor is moved to the next field. Two digit numbers can be entered in the left two or right two character locations. If an invalid number is entered, the cursor will not advance to the next field. After entering or editing the name and

IP address, press the SAVE function key to store the information in non-volatile memory. The information is retained even if the unit is turned off or the batteries are removed. To remove an entry from the list, press the right cursor key to select the entry and then press the star key. A “Delete Entry” message is displayed and pressing the SAVE function key clears the selected name and IP

Address.

OPERA TION

To test a hub, switch, router or NIC connect a patch cable from the RJ-

45 port on the equipment to the RJ-45 jack on the Pinger Plus.

LINK SCREEN

Turn on the Pinger Plus by pressing the “PWR” button. The unit scans the RJ-45 connection searching for Link signals. If no Link signals are found, a “No Link” message is displayed and a

REPEAT function is provided to rerun the search for a Link Partner. When proper

Link signals are found, the Pinger Plus displays the connection as a LAN, NIC or an Auto MDI-X port; the capabilites of the Link Partner; the speed and duplex the Pinger is using for the connection. When the Link is established, the

PING, DHCP and PortID function keys are displayed. Disconnecting the

Pinger will cause the unit to immediately restart the search for Link signals.

Note: If a Link Partner is transmitting NLP or MLT-3 Link signals instead of a Link

Code Word, the duplex mode is unknown

(shown as “UN” in the LINK screen) and the Pinger Plus will always connect at half duplex. PING tests can still be run even if there is a duplex mode mismatch.

Pressing the PING function key in the Link Screen presents the PING

Screen. The Up/Down cursor key is used to select: 1) enter and PING a new

IP address (1 to 99 times or continuously as shown next to “Name”) 2) PING one of eight preprogrammed IP addresses (see IP List Setup) 3) PING all of the one to eight preprogrammed IP LIST addresses 4) PING a Range of IP addresses or 5) PING one of eight

Profiles(see Profile Setup).

When an IP Address, IP List or IP Range is selected, pressing the PING function key transmits the PING packet and “Wait” is displayed until a response is received. A summary of the PING responses is displayed showing the number of PINGs transmitted and the number of Good and

Bad responses. Pressing the Up/Down cursor key shows, in numerical order, the results of each PING including the Round

Trip Time and if the received data is identical to the transmitted data

(Data:Good) or the data has been corrupted (Data:Bad).

Pressing the INFO function key displays the MAC address of the PINGed IP address. If no PING response is received within specified Timeout time (see Timeout Setup), “No Response” is displayed. When the PINGed IP address is in a different subnet than the

Pinger IP address, the unit first attempts to locate the default gateway. If the gateway does not respond, the Pinger displays a “NOGW” message indicating either the gateway is not operating properly or an incorrect gateway IP address was entered. When a PING response is received from another subnet, the MAC address of the Gateway is shown (GW MAC) by pressing the Info key.

Note: When the IP address of the device being PINGed is in the same subnet/VLAN as the IP address of the Pinger, the Subnet Mask can be “ON” or “OFF” and a Gateway IP address is not required. When the IP address is in a different subnet/VLAN, the Subnet Mask must be “ON” with the mask entered and the IP address of the Gateway must be entered. (See Subnet

Mask Setup and Gateway Setup).

CONTINUOUS PING

When the Pinger is configured to PING continuously (See Ping Count

Setup) the letter “C” is displayed to the left of “Name” in the PING Screen.

Pressing the PING function key displays the number of PINGs that have been sent and the percent of the PINGs with No Response or that had corrupted data. Pressing the Info function key displays the PING Address and the running average of the Round Trip Times for all PINGs that received a response.

Pressing the Info function key again displays the PING Address and the count of PINGs that had no response.

When “IP List” is selected and the PING function key is pressed, each

IP address stored in the IP List (see IP List Setup) is PINGed in turn. The same “Wait” and “No Response” messages are displayed as described above. After completing the PING of the last stored IP address, the IP List

Reponse screen is shown.

LIST RESPONSE SCREEN

The List Response screen shows the results of the PING to each of the stored IP addresses. The Up/Down cursor key is used to scroll through each IP address with Round Trip Time, Data status and MAC address presented for IP addresses that are found or “No Response” for IP addresses that did not respond within the Timeout period. Times less than one second are shown in milli-seconds (ms).

When “Range” is selected, the Range screen is displayed with start and stop IP addresses. The first three octets of the start and stop address must be the same and the fourth octet defines the range from one to a maximum of 255

IP addresses. Pressing the PING function key PINGs all the addresses in the range simultaneously. Each PING response can be viewed by pressing the Up/Down cursor key. Holding the key will cause the responses to scroll faster.

PING RESPONDER MODE

The Pinger Plus will respond to a PING request that is sent to the unit’s

IP address. When the unit is in the LINK Screen, a PING to the Pinger Plus

IP address presents the PING Received screen. The Ping Received screen shows the IP and MAC addresses of the PING source.

DHCP SCREEN

Pressing the DHCP function key in the Link Screen presents the DHCP

Screen and begins the DHCP client-server test.

Note: The MAC Address of the Pinger

Plus may have to be added to the Access

List of the DHCP Server for the Pinger messages to be accepted - see your

System Administrator for requirements.

The Pinger Plus transmits a “Discover” message to locate a DHCP server. If no DHCP Server responds to the message within the DHCP Timeout period (see Timeout Setup), the Pinger will retransmit the “Discover” message up to three more times. If no DHCP

Server responds after the fourth attempt, “No Response” is displayed.

Pressing the Repeat function key restarts the DHCP discover process. When a DHCP Server responds to the message, the Pinger displays “Server

Found” the IP Address of the Server and the IP Address assigned to the Pinger.

Pressing the INFO key displays the

Gateway IP Address and the Subnet

Mask used with the IP Address assigned by the DHCP Server. Note: If the DHCP Server does not provide the

Gateway IP Address, a 0.0.0.0 IP Address is displayed.

Pressing the PING key while in the DHCP Client mode presents the

PING screen with a “DHCP” message displayed and the IP Address of the

Gateway. If Gateway information is not available, the DHCP Server IP Address is shown.

Pressing the PING key from the IP Ping Screen transmits a PING that uses the IP Address, Gateway Address and Subnet Mask provided by the

DHCP Server instead of the IP Address, Gateway Address and Subnet Mask that were previously entered and stored in the Pinger. The Gateway IP

Address is automatically entered as the address to be PINGed (or the DHCP

Server address when Gateway information is not available). Alternatively, a new IP Address can be entered or the Up/Down cursor key can be used to select a previously stored address. Pressing the EXIT key returns the Pinger back to the LINK Screen and clears the DHCP Server assigned addresses and mask. Pressing the Setup key also clears the DHCP Server assigned information and transmits a DHCP release packet to the DHCP server so that the IP address is available for reassignment.

advertisement

Related manuals

Download PDF

advertisement