WORLD LEADER OF INNOVATIVE SOLUTIONS IN FIRE DETECTION AND ALARM SYSTEMS Product Catalogue Australia 2015 Contents Fire Control Panels ZoneSense DH4 Conventional ZoneSense PLUS Conventional ZoneSense PLUS AR Conventional LoopSense Intelligent FireFinder PLUS Intelligent FireFinder Intelligent Add Ons Alarm Systems Standalone Occupant Warning Panel Occupant Warning System Add-Ons EV3000 Emergency Control Panel EV3000 Emergency Control Panel - Add Ons Graphics Package Smart GraphicsHD 4 6 8 10 12 14 16 28 30 32 34 38 Detection & MCP’s Conventional Series 65 Detection Heat Detection Manual Call Points Sampling Duct Units Beam Detection Addressable XP95 Detection Discovery Detection Manual Call Points Duct Sampling Unit Specialist Detection Flame Detection Hazardous Area Detection Marine Detection Xpander Wireless Detection Aspirating Smoke Detection -Wagner Titanus Family High Sensitivity Detection System Aspirating Smoke Detection - FastSense 40 42 45 46 47 48 50 53 54 55 58 64 66 70 72 73 Audio Visual & Interfaces XP95 Interfaces 76 Conventional Audio Visual 80 Remote Indicators 83 Bells84 Warning Signs 85 Addressable Audio & Visual 89 Hazardous Area - Intrinsically Safe 92 Hazardous Area- Flameproof Equipment 93 Cable 2 Core TPS Cable 94 Ancillaries Electro-Magnetic Door Holders 97 Power Supplies 101 Batteries103 Test Equipment 103 Ancillary Equipment 105 Contact Page 107 www.ampac.net www.ampac.net 4 5 Fire Control Panels ZoneSense DH4 Conventional Specifications Power Supply Mains Supply voltage Nom. Operating voltage Power Supply Current Quiescent Current Operating Temperature Relative Humidity Zone Detection Circuit No of Zones Zone Monitoring Zone Quiescent Current No of Detectors/Circuits End Of Line (EOL) Max Cable Length Outputs Available Alarm Outputs (monitored) Door Holder outputs (monitored) Fire Output Relay (voltage free) Fault Output Relay (voltage free) Auxiliary DC Output 204 – 264 VAC @ 47 – 63Hz 27 VDC 1.6 A (max) 20 mA (without Door Holder) -5° to +55° C (no icing) 25% - 75% (non condensing) Four (4) x 2-wire system Open and Short circuit 4mA, 10uF EOL 40 (max) 10uF EOL 3km (Based on cable resistive and capacitive values of 50Ω and 1uF respectively) Open Collector, 250mA (2 O/P’s available) 10KΩ EOL Open Collector, 250mA (2 O/P’s available) 10KΩ EOL NO, C, NC Contact rating: 1A @ 30VDC NO, C, NC Contact rating: 1A @ 30VDC 150mA @ 24VDC Miscellaneous Features Class Change Input Alert Input Battery Monitoring Non-Latching, switched -ve Non-Latching, switched -ve 4 Way DIP switch array (factory set to “OFF”) Mechanical Packed Material Weight Packed excluding batteries H 310mm x W 500mm x D 110mm ABS Cabinet ABS/Blend High Impact Finish ABS Light Grey H 300 x W 360 x D 100 3kg Metal Cabinet 1.2mm Mild Steel Metal Oyster Matt Ripple H 300 x W 360 x D 100 5.2kg Product Overview The ZoneSense DH4 Control Panel is a simple and low cost 4 zone panel. It is an ideal fire panel for any small residential applications (not requiring brigade monitoring) or can also be used as a door holder control panel. Each of the 4 zones can be connected up to 40 x high quality commercial grade conventional fire detectors to deliver a high quality detection & alarm system. It is possible to use the ZoneSense panel in ‘Mains only’ option mode which eliminates the need to connect back up batteries. Both ABS and Metal versions are available. •• •• •• •• •• •• •• Dual Door Holder Outputs Mains Only Mode Low Quiescent Current Walk Test Facility Alert Input Up to 40 Conventional detectors per Zone Available in ABS (BX1) and Metal (BX10) cabinet versions www.ampac.net Item Numbers ZoneSense DH4 ABS (BX1) excl Batteries ZoneSense DH4 METAL (BX10) excl Batteries Metal BX10 Surround 2250-4200 2250-4250 ENC3016-A www.ampac.net 6 7 Fire Control Panels ZoneSense PLUS Conventional Specifications Power Supply Mains Supply voltage Nom. Operating voltage Power Supply Current Quiescent Current Zone Detection Circuit No of Zones Zone Monitoring Zone Quiescent Current No of Detectors/Circuits End Of Line Value (EOL) Max Cable Length respectively) Product Overview The Ampac ZoneSense PLUS Fire Alarm Control Panel is a versatile four or eight zone conventional panel. The user friendly navigation system provides simple operation during an emergency while also enabling complex cause and effect programming to be undertaken. A range of modular panel add-on kits allows the panel to be professionally tailored to the requirements of each installation. This means small conventional panels can now be used in a wider range of applications. ZoneSense PLUS offers you complete control. The panel can be easily upgraded and programmed on site. ZoneSense PLUS is approved to AS4428 and is available in ABS (BX1) or metal cabinets (BX20) with either four (4) or eight (8) zone conventional detection circuits •• •• •• •• •• Complies with AS4428.1 Available in 4 Zone or 8 Zone Panels Up to 40 Conventional detectors per zone RS485 port supports a range of Add-on modules vailable in ABS (BX1) and Metal (BX20) cabinet versions www.ampac.net 204 – 264 VAC @ 47 – 63Hz 27 VDC 2 A (max) 40.5 mA (min) Four (4) or Eight (8) x 2-wire system Open and Short circuit 4mA, 10uF EOL 40 (max) 3K3Ω (default), 4K7Ω, 6K8Ω, 10KΩ and 10uF 3km (Based on cable resistive and capacitive values of 50Ω and 1uF Outputs Comms Output EXT Bell Output (monitored) Warning Sys Output (monitored) ACF Output (monitored) ASE Output (monitored) Reset/Buzzer Fire Alarm Output Relay (voltage free) Fault Output Relay (voltage free) Auxiliary DC Output (monitored) RS485 (4 and 8 zone only) 1A (max) 10KΩ EOL 1A (max) 10KΩ EOL 1A (max) 10KΩ EOL 1A (max) 10KΩ EOL Output Open Collector, 40mA 15sec pulse NO, C, NC. Contact rating: 1A @ 30VDC NO, C, NC. Contact rating: 1A @ 30VDC 500mA @ 24VDC10KΩ EOL Environmental Operating Temperature Relative Humidity -5° to +55° C (no icing) 25% - 75% (non condensing) Mechanical Material Finish Weight packed ex Batteries Dimensions (mm) ABS Metal Ancillary ABS Cabinet ABS/Blend High Impact ABS Light Grey 3kg Metal Cabinet 1.2mm Mild Steel Metal Oyster Matt Ripple 8.5kg 300 H x 360 W x 100 D 500 H x 405 W x 145 D 250 H x 405 W x 145 D Item Numbers ZoneSense PLUS 4 Zone SPX1 Inc Batteries ZoneSense PLUS SP1x OWS25W Inc Batteries ZoneSense PLUS 4 Zone SP1x OWS50W Inc Batteries ZoneSense PLUS 8 Zone SP1X Inc Batteries ZonesSense PLUS 8 Zone SP1X OWS25W Inc Batteries ZoneSense PLUS 8 Zone SP1X OAWS50W Inc Batteries Ancillary Cabinet 2553-0410 2553-0410-1100 2553-0410-1200 2553-0810 2553-0810-1100 2553-0810-1200 4210-0040 www.ampac.net 8 9 Fire Control Panels ZoneSense PLUS AR Conventional Product Overview The ZoneSense PLUS AR (Agent Release) Panel is a dedicated panel for agent release systems. Housed in a metal cabinet, the ZoneSense PLUS AR is available in either four (4) or eight (8) zones. Based on a ZoneSense PLUS Fire Alarm Control Panel (FACP), the AR version is fitted with an Agent Release Panel Add-on (control card and termination board) and a dual action yellow manual call point as standard. The Agent Release panel add-on option is factory set. •• •• •• •• •• •• Dedicated Agent Release system - purpose built with a host of ancillary products to suit Comprehensive system status – the AR panel includes a number of system status indicators that facilitates ease of operation and maintenance Local Control Station with control and indication – mimics full status of the Agent Release panel. An outdoor version of this product is available User interface and operation based around Industry Fire Emergency procedures – ensures that the system installed is intuitive and easy to use Dual action Manual Call Point – the yellow MCP is a break glass type and requires a dual action to be activated i.e. lift the protective transparent cover and break the glass Agent Release Panel is compliant with AS4214 www.ampac.net Specifications Power Supply Mains Supply voltage Nom. Operating voltage Power Supply Current Quiescent Current 204 – 264 VAC @ 47 – 63Hz 27 VDC 2 A (max) 40.5 mA (min) Zone Detection No of Zones Zone Monitoring Zone Quiescent Current No. of Detectors per Zone Zone End Of Line Value 4 or 8, 2 Wire Open and Short circuit 4mA, 10uF EOL 40 max 3K3Ω (default), 4K7Ω, 6K8Ω 10KΩ and 10uF Outputs EXT Bell Output Warning Sys Output ACF Output ASE Output Fire Alarm Output Relay Fault Output Relay Auxiliary DC Output Reset/Buzzer Output 500mA (max) 10KΩ EOL monitored 500mA (max) 10KΩ EOL monitored 500mA (max) 10KΩ EOL monitored 500mA (max) 10KΩ EOL monitored NO, C, NC Contact: 1A @ 30VDC NO, C, NC Contact rating: 1A @ 30VDC 500mA @ 24VDC 10KΩ EOL monitored Open Collector, 40mA 15sec pulse Environmental Comms Output Operating Temperature Relative Humidity RS485 -5° to +55° C 25% - 75% non condensing Dedicated Agent Release Inputs and Outputs Pressure Switch Input Low Pressure Switch Input Interlock Input Gas Fired Output System Inoperative Output Stage 1 Relay Output Stage 1 Monitored Output Stage 2 Relay Output Stage 2Monitored Output Release Initial Agent Output Release Reserve Agent Output Monitored Input Monitored Input Monitored Input Volt Free Changeover [email protected] Volt Free Changeover [email protected] Volt Free Changeover [email protected] 1Amp 10KΩ EOL (Voltage reversal) Volt Free Changeover [email protected] 1Amp 10KΩ EOL (Voltage reversal) Monitored current limited 2A max Monitored current limited 2A max Mechanical Material 1.2mm Mild Steel FinishRipple Cabinet Dimensions (mm) 500(H) x 405(W) x 150(D) Ancillary Cabinet Dimensions (mm) 250(H) x 405(W) x 145(D) Weight packed ex Batteries Metal 8.5kg Item Numbers ZoneSense PLUS 4 Zone SP1X Agent Release Inc Batteries ZoneSense PLUS 8 Zone SP1X Agent Release Inc Batteries 2553-0410-0100 2553-0810-0100 www.ampac.net 10 Fire Control Panels LoopSense Intelligent 11 Specifications Power Supply (General) Dimensions Weight Power Supply Maximum Battery Capacity Input Voltage Output Voltage Battery Discharged Cut Off Voltage Material Finish SP1XP8X 00H x 405W x 150Dmm 845H x 515W x 175Dmm 9kg 15kg 3 Amp PSU version 5 Amp PSU version 26Ah 40.0Ah 204 - 264VAC 27.5VDC +/- 0.1VDC 21VDC 21VDC 1.2 mm steel Surf Mist Ripple Loop Quiescent Current(1 Loop Panel) Quiescent Current (2 Loop Panel) Loop Capacity Max No of Detectors/Devices per Loop Cabling Requirements Fault supervision 115mA 135mA 500mA max 126 2 core 1.5 to 2.5 mm2 O/C, S/C, overcurrent Outputs/Inputs Outputs (SupervisedProgrammale) Relay outputs (Programmable) Open Collector Output (Programmable) Auxiliary VDC(Programmable) Inputs (Programmable) 4 x 24VDC @ 500mA max 3 x Voltage free 24VDC @ 1A 2 x 30mA 2 x 24VDC @ 500mA 4 x O/C, S/C, 10K EOL Communications Port Internal to LoopSense External to LoopSense Printer port PC Interfacing RS485 RS485 RS232 or Parallel RS232 or USB 2.0 Environmental Operating temperature Relative humidity IP rating -5°C to +55°C (no icing) 25% to 75% (non condensing) IP30 Product Overview LoopSense is an Intelligent Analogue Addressable Fire Alarm Control Panel. Available in one or two loops, the LoopSense comes packed with options and features that facilitate flexibility, ease of installation and commissioning. •• •• •• •• •• •• •• •• •• Complies to AS7240-2:2004, AS7240-4:2004, and AS4428-3:2010 -ActivFire listed Clear back-lit 240 x 64 graphic LCD 500mA loop current Advanced balanced loop design for noise rejection Auto learn facility Supports extensive range of Add Ons, including the SmartTerminal Repeater User friendly Loopmaster programming software tool Laptop connection using USB2.0 or RS232 serial port Available in ABS (BX1) and Metal (BX10) cabinet versions www.ampac.net Item Numbers LoopSense 1 Loop 3A SP1X LoopSense 1 loop 6A SP8X LoopSense 2 Loop 3A SP1X LoopSense 2 Loop 6A SP8X LoopSense 1 Loop 3A SP1X OWS25 LoopSense 2 Loop 3A SP1X OWS25 LoopSense 1 Loop 3A SP1X OWS50 LoopSense 1 Loop 6A SP8X OWS50 LoopSense 2 Loop 6A SP8X OWS50 8251-0210 8251-0210 8251-0113 8251-0213 8251-0110-1100 8251-0210-1100 8251-0110-1200 8251-0213-1200 8251-0213-1200 www.ampac.net 12 Fire Control Panels FireFinder PLUS Intelligent 13 Specifications Power Supply (Gereral) Cabinet SP1X Power Supply 5A PSU version Input Voltage 195 - 264VAC Protection 2 Amp 3AG Output Current 5.6 Amps Charger Current 1.25A Maximum Battery Capacity: 26Ahr Charger Output Voltage: 27.5 +/- 0.1VDC Battery Type: 2 x 12V Sealed Lead Acid Discharge Cut-off voltage: 21VDC Loop Panel Quiescent Current 1 Loop Additional Loops (even) Additional Loops (odd) Loop Capacity Max No of Devices per Loop Cabling Requirements Fault supervision Inputs/Outputs Outputs (Programmable) Relay outputs (Programmable) Auxiliary Power Outputs Inputs (Programmable) Product Overview FireFinder Plus is an Intelligent Analogue Addressable Fire Alarm Control Panel that is available in 1 to 8 loop panel options. The FireFinder Plus is suitable for medium to large sized fire detection systems and is compatible with Apollo XP95, Discovery and Series 90 detectors. Powerful and flexible programming is achieved via AMPAC’s configuration tool ConfigManager Plus which includes many dedicated pre-engineered programming functions. Simple system programming is easily achieved via the front panel. FireFinder Plus is configurable as a peer to peer network up to 100 panels/nodes with a maximum of 150 Loops. •• •• •• •• •• •• •• •• •• •• •• •• Fully approved to AS2740-2 , AS720-4 and AS4428.3:2010 Fully Expandable 1 to 8 Loop Fire Alarm Control Panel Large Graphic (240 x 64 pixel) Display 500mA Loop Current 4 Programmable Monitored Inputs 4 Programmable Monitored Outputs 5 Programmable Relays 2 Auxiliary Power Outputs Programmable via front panel Networkable Supports High Level Graphics Interface Supports a Range of Panel Add-ons www.ampac.net 220mA +40mA for each Loop +75mA for each Loop 500mA max per Loop 126 2 core 1.5 to 2.5mm² O/C, S/C, Over current 4 x 24VDC @ 1 Max, 10K EOL 5 x Voltage Free - [email protected] 2 x 24VDC @ 500mA 4 x O/C, S/C, 10K EOL Communication Comms External to FACP Comms Printer port Comms PC Interface RS485 RS232 or Parallel RS232 or USB 2.0 Environmental Temperature Humidity -5ºC to + 40ºC 25% to 95% (non-condensing) Mechanical Material Colour/Finish Dimensions (mm) SP1M SP1X SP8X SP16X IP Rating Cabinet SP8X/SP16X 5A PSU / 22A PSU Version 195 - 264VAC 2 Amp 3AG (5A PSU)/ 5 Amp 3AG (18A PSU) 22 Amp 1.25A / 3A 40Ahr 1.2mm Mild Steel Surf Mist Ripple 500H x 405W x 150D 500H x 405W x 150D 845H x 518.5W x 173D 1200H x 625X x 240D IP30 (Indoor Use Only) Item Numbers (Addressable) FireFinder PLUS 1 Loop 5A SP1X FireFinder PLUS 1 Loop 5A Agent SP1 FireFinder PLUS 1 Loop OWS25 5A SP1 FireFinder PLUS 1 Loop OWS50 5A SP1 FireFinder PLUS 1 Loop 5A SP8X FireFinder PLUS 1 Loop Agent 5A SP8 FIREFINDER+ 1 Loop AGENT 5A SP8 FIREFINDER+ 1 Loop OWS50 5A SP8 8651-0110 8651-0110-0100 8651-0110-1100 8651-0110-1200 8651-0113 8651-0113-0100 8651-0113-0700 8651-0113-1200 (Conventional) FireFinder PLUS 8 Zone 5A SP1X FireFinder PLUS 8 Zone OWS25 5A SP1 FireFinder PLUS 8 Zone OWS50 5A SP1 8653-0810 8653-0810-1100 8653-0810-1200 www.ampac.net 14 Fire Control Panels FireFinder Intelligent Product Overview FireFinder is a state of the art multi microprocessor controlled Intelligent Fire Alarm Control Panel. Modular in design, the FireFinder provides flexibility and versatility that can be configured to operate with both intelligent analogue addressable and conventional devices in the one system. Available in single loop or multiple loop configurations, the FireFinder supports the leading Apollo XP95 and Discovery detector protocols. The Ampac ConfigManager software tools provide a powerful combination with the FireFinder to configure the system operational and functional characteristics of an installation. Enhanced networking capabilities offer the user extended applications with FireFinder incorporating a Master/ Slave Fire control panel arrangement, true Peer to Peer systems, data gathering panels and SmartGraphics a PC based application for the supervision, monitoring and control of larger fire management systems. •• •• •• •• •• •• •• •• •• •• •• •• •• Complies with AS4428.1 and AS1603.4 Clear back-lit 40 character 8 line LCD display Programming options via the front panel or laptop computer Remote system interrogation and diagnostics Extensive Alarm Management resources Self Auto Learn capabilities Day Night sensitivity settings Versatile multi processor architecture Event log and printer options SPOT – Single Person Operation Test Flexible modular expansion and panel Add Ons Optional 32, 64, 96 & 128 zone indicators SmartTerminal repeater options www.ampac.net 15 Specifications Power Supply Finish Material Input Voltage Output Voltage Output Current Battery Type Arch White Ripple 1.2mm steel 85 to 264Vac (47-63Hz) 27Vdc 2A, 5.6A or 18A 2 x 12V SLA batteries Loop Quiescent Current Devices per Loop Loop Current Devices per Zone Conventional Zone EOL Cable (Loop and Conventional Circut) 240mA (min 1 Loop no load) 126 250mA 40 3K3 2 core 1.5 to 2.5mm² Outputs/Inputs Outputs Bell 1 Bell 2 Plant Monitored Plant Un-Monitored Warn Sys Monitored Warn Sys Un-Monitored Fault Monitored Fault Un-Monitored Isolate Alarm Valve Monitor Batt Fail (normally energised) Battery Output Aux Power Output 1 Aux Power Output 1 EV40 use Aux Power Output 2 DBA/MCP 2 Amp Fused 2 Amp Fused 1 Amp Fused, 10K EOL 1 Amp voltage free contact 1 Amp Fused, 10K EOL 1 Amp voltage free contact 1 Amp Fused, 10K EOL 1 Amp voltage free contact 1 Amp voltage free contact 1 Amp voltage free contact 1 Amp voltage free contact 1 Amp voltage free contact Protected 1 Amp Fused 3 Amp Fused 1 Amp Fused Monitored 10K EOL Environmental Temperature Humidity IP Rating 5ºC to + 55ºC 25% to 75% (non-condensing) IP51 Item Numbers (Conventional) FireFinder SP1X 16 Zone AS4428 FireFinder SP1X 16 Zone ASE FireFinder SP1X 16Zone OWS25 FireFinder SP1X 16Zone OWS50 FireFinder SP1X 16Zone (Addressable) FireFinder SP1X 1Loop AS4428 FireFinder SP1X 1Loop ASE FireFinder SP1X 1Loop OWS50 8550-1150 8550-1250 8550-1450-1100 8550-1530-1200 8550-1151 8550-1100 8550-1200 8550-1440-1200 www.ampac.net 16 Fire Control Panels 17 Add Ons (*FF+ - FireFinder PLUS compatable, *FF - FireFinder compatable, *LS - LoopSense compatable, *ZSP- ZoneSense PLUS compatable) Analogue Loop Upgrade Kit *FF+ SmartTerminal Repeater *FF+ *LS *FF •• This kit adds an intelligent analogue loop to the FireFinder PLUS Control Panel •• For an odd numbered loop upgrade the kit consists of an I/O CPU module, cable and termination card •• An even numbered loop upgrade consists of an I/O CPU module and cable The SmartTerminal has been designed to display the status of and provide limited controls for the FireFinder Plus and LoopSense Fire Alarm Control Panels (FACP) in m Voltage Quiescent current Loop current Operating temperature Relative humidity Weight 24 VDC 40 mA 500 mA max. -5°C to +55°C (no icing) 0 to 95% (non condensing) 200 grams FireFinder Plus Slave CPU Board FireFinder Plus Term Board FireFinder Terminal Repeater 8610-0001 8610-0002 Operating Voltage Internal (24Vdc) 18 – 27 V DC External (240Vac) 204 - 264VAC Quiescent Current 12.5mA (backlight off, buzzer off ) Maximum Current 43.8mA (backlight on, buzzer on) Temperature -5ºC to + 55ºC Humidity 25% to 75% (non-condensing) Cabling Requirements 2 core 1.5 to 2.5mm² External Power Supply 1.8A plus 400mA Battery Charging (4350-0005 only) Battery Size 3.2AHr (4350-0005 only) MaterialABS Dimensions BX05 195 (H) x 325 (W) x 50 (D) BX1 300 (H) x 360 (W) x 100 (D) Loop Module Expansion Kit *FF+ •• •• Expands the capacity of the FireFinder to accommodate a further four loops, 64 conventional zones, four I/O modules or any combination of the above Requires a main controller board Voltage Quiescent current Operating temperature Relative humidity Weight 24 VDC 5 mA -5°C to +55°C (no icing) 0 to 95% (non condensing) 110 grams FireFinder Plus Loop Expansion Board 4350-0001 4350-0002 4350-0003 FireFinder Plus and LoopSense FF+/LS SmartTerminal (BX1 enclosure) FF+/LS SmartTerminal inc PSU (BX1 enclosure) FF+/LS SmartTerminal (BX05 slimline enclosure) Wall Mount Surround 4350-0004 4350-0005 4350-0006 4210-0046 8610-0003 2 Wire Network Interface Board *FF+ High Level Interface Expander or Port Expander Board *FF+ *LS *FF •• •• •• •• •• •• •• •• •• •• •• Supports Redundant Network, with Isolated Network In and Out Ports Up to 99 Network Nodes 115200 Baud Rate Distance Between Nodes 1.2km Uses Industry Standard RS485 Diagnostic LEDs Voltage 27 VDC Quiescent Current 41 mA ProtocolRS485 Max distance (between NICs) 1.2km Cable requirements 2 Core Screened Fire Resistant Operating temperature -5°C to +40°C Relative humidity 0 to 95% (non condensing) Network Interface Card 2 Wire www.ampac.net LoopSense/FireFinder Plus Terminal Repeater FireFinder FF SmartTerminal (BX1 enclosure) FF SmartTerminal inc PSU (BX1 enclosure) FF SmartTerminal (BX05 slimline enclosure) 4210-0006 Building Management Paging system Nurse Call Systems SmartGraphics MODBUS Voltage Quiescent current Max current Relay contact rating Operating temperature Relative humidity Weight High Level Interafce - Factory Fitted High Level Interface - Add-On Kit 24 VDC 2.4 mA 80 mA 1 amp at 24 VDC -5°C to +55°C (no icing) 0 to 95% (non condensing) 130 grams 159-0268 4310-0080 www.ampac.net 18 Fire Control Panels 19 Add Ons 8 Way Relay Board *FF+ *LS *ZSP 8-way Sounder Board *FF+ *LS *ZSP •• •• •• •• •• •• Provides volt free change over contacts 8 relay outputs per board Remote version available – DIN Mount chassis Remote version communication via RS485 serial link Voltage Quiescent current Max current Relay contact rating Operating temperature Relative humidity Weight Provides 8 monitored switched 24 VDC outputs per board Max 1 per FireFinder PLUS Voltage Quiescent current Max current Output rating (ea) EOL Monitoring Value Operating temperature Relative humidity Weight 24 VDC 2.4 mA 80 mA 3 amp at 24 VDC -5°C to +55°C (no icing) 0 to 95% (non condensing) 130 grams 24 VDC 5.6 mA 26 mA 500 mA at 24 VDC 10k Ω -5°C to +55°C (no icing) 0 to 95% (non condensing) 100 grams Sounder Board Relay Board Relay Board (Remote) 4310-0060 4310-0050 4310-0055 Fire Fan Module *FF+ *LS *FF *ZSP 8 Zone Conventional Board *FF+ *LS •• Supports up to eight conventional zones •• Selectable end of line device 3K3, 4K7, 6K8, 10K or 10µF capacitor •• Supports head removal requirement on each zone •• Supports up to 40 conventional devices per zone circuit (ORBIS/Series 65) •• Programmable latching and non-latching (self-resetting) input on each zone circuit Voltage Quiescent current Alarm current Operating temperature Relative humidity Size Weight 24 VDC 15mA (including capacitive EOL current) plus device current 43mA (one circuit in alarm) -5°C to +55°C (no icing) 0 to 95% (non condensing) 72.5 x 155mm 120 grams 8 Zone Conventional Board •• •• •• •• •• •• •• Four (4) Controls per Module Status indication for Run / Fault / Stop Controls for On / Auto / Off Audible and visual feedback of button press Built in Plant Trip Reset Supports 3, 4 and 5 Wire Connections Available in Hard Wired or loop driven versions Operating Voltage 27VDC Dimensions Controller Card Fits standard Panel Cut-Out Termination Board 155mm x 72mm Contact Rating 1 @ 24VDC ApprovalAS1668 Hard Wired (Includes controls and termination board) Loop Driven (Controls only) 4310-0021 4310-0071 4310-0082 32 Zone Indicator Card *FF+ *LS •• •• •• •• •• 16 way Input Board *FF+ *LS *ZS •• •• •• •• Provides inputs for sprinkler pumps, tanks, valves, shutdowns, etc 16 inputs per board Inputs map to relays or indicators Programmed via the LoopMaster Voltage Quiescent current Max current Output rating Operating temperature Relative humidity Weight Input Board www.ampac.net 24 VDC 2.6 mA 45 mA 0.5 amp at 24 VDC -5°C to +55°C (no icing) 0 to 95% (non condensing) 120 grams Provides 32 Zone LED’s capable of indicating zone Fire, Disabled, Fault and Dependency B. Suitable for use with the FireFinder range of FACP’s Suitable for use with LoopSense FACP Customisable zone identification label Fully programmable via LoopMaster Voltage Quiescent current Max current Output rating Operating temperature Relative humidity Weight 4310-0040 32 Zone Indicator Card 27 VDC 3.6 mA 8mA 0.5 amp at 24 VDC -5°C to +55°C (no icing) 0 to 95% (non condensing) 100 grams 4310-0086 www.ampac.net 20 Fire Control Panels 21 Add Ons Zone Disable and Indicator Module *FF+ *LS *FF Agent Release Module *FF+ *LS *FF *ZSP •• •• •• •• •• •• •• •• •• •• Provides 8 Programmable Zone Disable Switches Provides 8 Status LEDs Customisable Switch Identification Label Voltage27VDC Quiescent current 3.6 mA Max current 8 mA CommunicationRS485 Operating temperature -5°C to +55°C (no icing) Relative humidity 0 to 95% (non condensing) Weight 100 grams Zone Disable & Indicator Module 4310-0087 8 Switch/Indicator Module *FF+ *LS *ZSP •• •• •• •• •• 8 x Push Button On / Off switches Controls and Monitors solenoid test switches, manual shutdowns and etc Programmable via the ZoneSense PLUS front panel Programmable via ConfigManager for the FireFinder range of panels Programmable via LoopMaster for the LoopSense range of panels Voltage Quiescent current Max current Operating temperature Relative Humidity Weight 24 VDC 3.6 mA 8 mA -5°C to 55°C (no icing) 0 to 95% (non condensing) 100 grams Switch/Indicator Card Network Interface Card (NIC)- 2 Wire Network *FF 24 VDC 9 mA 52 mA 1 amp at 24 VDC -5°C to +55°C (no icing) 0 to 95% (non condensing) 110 grams Fire Brigade Board 4310-0070 Agent Release- Local Control Station *FF+ *LS *FF *ZSP •• •• •• •• •• •• Remote Agent release LCS Complies with AS4214 For use only with Agent release Module 4310-0011 Double Action manual Agent release facility Toggle between initial & reserve agent Can install up to 8 x LCSs per panel Local Control Station www.ampac.net 4310-0011 4310-0030 Provides common outputs for connection to fire brigade signalling equipment 5 outputs – Alarm, Fault, Isolate, Battery Fail and 2nd Alarm Voltage Quiescent current Max current Output rating Operating temperature Relative humidity Weight Pressure Switch Input Monitored Input Low Pressure Switch Input Monitored Input Interlock Input Monitored Input Gas Fired Output Volt Free Changeover [email protected] System Inoperative Output Volt Free Changeover [email protected] Stage 1 Output Monitored Stage 2 Output Monitored Release Initial Agent Output Monitored current limited 2A max Release Reserve Agent Output Monitored current limited 2A max System Capacity FireFinder 8 Maximum LoopSense 8 Maximum ZoneSense Plus 1 Maximum Agent Release Module Fire Brigade Board *LS ZSP •• •• ompliance with AS4214 C Controls & Monitors Agent release system Outputs for warning signs & activation devices Inputs for signals from pressure switches & valves Serial connection to Agent release (LCS) Local control Station Programmed via the FACP front panel Location or title descriptor label 4310-0019 •• The NIC gives the FireFinder network capabilities via the RS422 communications port •• Provides an additional RS232 communications port when connected to Controller Interface Card (CIC) •• High level interface for Building Management or ModBus protocol for SmartGraphics and PLCs •• The NIC can be isolated from other network devices •• Loop In/Loop Out for easy installation Voltage Quiescent Current Available Ports Max distance (between NICs) Cable requirements Operating temperature Relative humidity Weight 24 VDC 65 mA RS422 – network RS232 – serial comms 1.2km RS485 – 1 pair twisted/screened RS232 – 1 pair twisted/screened -5°C to +55°C (no icing) 0 to 95% (non condensing) 225 grams SP1X159-0258 SP8X159-0259 SP16X/Rack159-0260 Add-On Kit 4310-0079 www.ampac.net 22 Fire Control Panels 23 Add Ons Module Expansion Kit for Modules (5-8) *FF 8-Way 5A Relay *FF •• •• •• •• E xpands the capacity of the FireFinder to accommodate a further four loops, 64 conventional zones, four I/O modules or any combination of the above Requires a main controller board Voltage Quiescent current Operating temperature Relative humidity Weight 24 VDC 5 mA -5°C to +55°C (no icing) 0 to 95% (non condensing) 110 grams SP8X Loop Module Expansion Kit SP16x/Rack Loop Module Expansion Kit •• 159-0012 159-0022 Each upgrade panel add-on offers 8 voltage free relay outputs. Each output is rated at 5 amps, 24 VDC Each relay has a single normally open/close volt-free contact extended to a wireprotected screw terminal The standard 8-way relay upgrade requires spare capacity available on a 128/128 I/O and 16/16 I/O module Voltage Quiescent current Operating temperature Relative Humidity Weight 24 VDC 5 mA (Serial Relay Board) -5°C to 55°C (no icing) 0 to 95% (non condensing) 190 grams SPX 8-Way 5A O/P Relay Rack 8-Way 5A O/P Relay 159-0013 159-0015 8 Way Serial Relay Output Board *FF •• •• •• Each serial relay output board offers 8 voltage free relay outputs, each rated at 5 amps, 24 VDC Each relay has a single normally open/close volt-free contact extended to a wireprotected screw terminal The serial 8-way relay is driven directly from the main controller board Voltage Quiescent current Relay output current Operating temperature Relative humidity Weight Rack 8 Way Serial Relay Output Board SPX8 8 Way Serial Relay Output Board 24 VDC 5 mA 5 Amps at 24 VDC -5°C to +55°C (no icing) 0 to 95% (non condensing) 190 grams 159-0072 159-0079 8 Way Bell Monitor Board *FF •• •• •• The 8-Way Bell Monitor has 8 switched 24V DC sounder outputs The outputs are programmable and monitored for open or short circuit The board connects directly to the main controller board Voltage Quiescent current Max sounder output current Max output current Operating temperature Relative humidity Weight 24 VDC 20 mA 1 Amp each 4 Amps per board -5°C to +55°C (no icing) 0 to 95% (non condensing) 250 grams 8 Way Bell Monitor Board 159-0071 4 Plus 4 Bell Monitor *FF •• •• •• The 4 Plus 4 Bell Monitor has screw terminals for 4 voltage free contacts and 4 switched 24V DC sounder outputs The outputs are programmable and monitored for open or short circuit The board connects directly to the main controller board Voltage Quiescent Current Available Ports Max distance (between NICs) Cable requirements Operating temperature Relative humidity Weight 4 Plus 4 Bell Monitor Board www.ampac.net RS422 RS232 24 VDC 65 mA Network Serial comms 1.2km 2 pair twisted/screened 1 pair twisted/screened -5°C to +55°C (no icing) 0 to 95% (non condensing) 225 grams 159-0069 16 Way Conventional Zone Card *FF •• •• •• •• Adds 16 conventional Alarm Zone Circuits Kit consists of an I/O CPU module, cable and 16 zone termination card Supports up to 40 conventional detectors (Series 60, Series 65 or Orbis) per zone Fixed 3K3 End-Of-Line device Voltage Quiescent current Operating temperature Relative humidity Weight SP8X/SP16X 16 Way Conventional Zone Card Rack 16 Way Conventional Zone Card 24 VDC 145 mA -5°C to +55°C (no icing) 0 to 95% (non condensing) 185 grams 159-0005 159-0006 www.ampac.net 24 Fire Control Panels 25 Add Ons 16 Opto Inputs *FF Panel Mounted LED Indicators *FF •• •• •• •• Provide flexibility to include additional LED indicators to the FireFinder SP1X and SP8X •• Available in three versions: •• – 32 zone alarm only indication (red) •• – 16 zone alarm/fault indication (red/amber) •• – 32 zone general indication (amber) •• Serial connection to the FireFinder panel •• Simple clip installation •• Indicators remain illuminated until reset by the panel •• Indicators are tested by the FireFinder panel’s lamp test control The Opto Input panel add-on provides 16 programmable electrically isolated inputs to the FACP The input from a third party source should be a volt-free contact This upgrade requires spare capacity available on a 128/128 I/O and 16/16 I/O Interconnect Module Voltage Quiescent current Operating temperature Relative Humidity Weight 24 VDC 5 mA -5°C to 55°C (no icing) 0 to 95% (non condensing) 185 grams SP 16 Opto Input Rack 16 Opto Input 159-0010 159-0011 Voltage Quiescent current Max current Operating temperature Relative humidity Weight 27 VDC 30 mA 40 mA -5°C to +55°C (no icing) 0 to 95% (non condensing) 100 grams FireFinder SP1X 32 Zone Alarm Only Indication (Red) FireFinder SP8X 32 Zone Alarm Only Indication (Red) FireFinder SP1X 16 Zone Alarm/Fault Indication (Red/Amber) FireFinder SP8X 16 Zone Alarm/Fault Indication (Red/Amber) FireFinder SP1X 32 Zone General Indication (Amber) FireFinder SP8X 32 Zone General Indication (Amber) 159-0106 159-0089 159-0107 159-0108 159-0123 159-0124 Remote Mounted LED Indicators *FF •• •• •• •• The remote LED indicator boards provide facilities to mimic the FireFinder zone LEDs and switches Connects to the RS485 communications bus via the controller interface card Allows the custom design of geographic site layout mimics Each termination board connects up to 32 zone LEDs – 31 boards maximum – total 992 zone indications Voltage Quiescent current Max current Communication mode Baud rate Communication cable No. of boards No. of zones Buzzer external max current On board status indication Common inputs Operating temperature Relative humidity FireFinder LED Mimic Driver 32 Way Mimic Output Termination Board FireFinder 16 Zone LED Display Board www.ampac.net 27 VDC 8 mA max 100 mA RS485 19200 max 1 x pair twisted and screened 31 max 992 zones max 20 mA Power on – green Normal – green Fault – yellow Reset Lamp test Buzzer mute Bell isolate Manual evacuate -5°C to +55°C (no icing) 0 to 95% (non condensing) Modem *FF •• •• •• •• •• T he modem allows a remote access to FireFinder Configuration and application software can be uploaded or downloaded via the modem Wireless Modem requires available signal from appropriate network All modems are AUSTEL approved Great tool to provide remote support Voltage Data transfer rate Comms to FACP Operating temperature Relative Humidity Weight 159-0145 159-0152 159-0218 SPX Modem Rack Modem Wireless Modem 27 VDC 9600 baud max RS 232 -5°C to 55°C (no icing) 0 to 95% (non condensing) SP & Rack: 1kg Wireless: 5kg 159-0033 159-0065 159-0068 www.ampac.net 26 Fire Control Panels 27 Add Ons Fibre Optic Network Interface *FF Panel Printer *FF+ *LS *FF •• •• •• •• •• •• •• •• •• 4 versions available to suit your cabling scheme on site Redundant loop integrity (same as copper) A network interface card is still required at each FACP node Maximum distance using ‘Multimode’ (between nodes) up to 5km; using Single Mode 50km Supply Voltage 24 VDC Quiescent Current 80 mA @ 24 VDC Optical Connector ST standard Ports Available RS422/RS485 Size (mm) 104D x 104W x 25H Weight280g Operating Temperature -20°C to +75°C Humidity 0 to 95% relative, non-condensing FireFinder Fibre Optic Multimode 2 Core FireFinder Fibre Optic Multimode 1 Core FireFinder Fibre Optic Single Mode 2 Core FireFinder Fibre Optic Single Mode 1 Core The dot matrix printer provides hardcopy activity report Alarms, faults, isolates and system logs may be printed 3 colour status LED Self test mode Easy maintenance for replaceable ribbon cassette and paper roll Voltage Quiescent current Character size Operating temperature Relative humidity Weight 159-0251 159-0252 159-0253 159-0254 5 VDC 1A @ 5 VDC 5 x 7 dots -5°C to +55°C (no icing) 25 to 95% (non condensing) 380 grams Printer C/W Mounting plate (Suit Australian White SP1 cabinet) 159-0084 Printer C/W Mounting plate (Suit Australian) 159-0110 Paper Rolls (10) MIS1981 RibbonMIS1982 Analogue Loop Upgrade Kit *FF •• •• •• This kit adds an intelligent analogue loop to the FireFinder Control Panel For an odd numbered loop upgrade the kit consists of an I/O CPU module, cable and termination card An even numbered loop upgrade consists of an I/O CPU module and cable Voltage Quiescent current Loop current Operating temperature Relative humidity Weight 24 VDC 40 mA 250 mA max. -5°C to +55°C (no icing) 0 to 95% (non condensing) 200 grams 1 Loop Upgrade Kit- even numbered loop SP1X 1 Loop Upgrade Kit and Processor- odd numbered loop SP1X Even No. Loop SP16X/Rack Even No. Loop SP8 Odd No. Loop SP16X/Rack www.ampac.net 159-0001 159-0003 159-0002 159-0046 159-0004 www.ampac.net 28 Alarm Systems 29 Standalone Occupant Warning Panel Item Numbers EvacU 25W 3A EvacU 50W 3A EvacU 100W (2 x 50W) 5A EvacU 150W (3 x 50W) 10A EvacU 200W (4 x 50W) 10A Handheld Microphone Dual XENON Dual LED Beacon Shallow Base Dual LED Beacon Deep Base 6050-0010-1100 6050-0010-1200 6050-0010-1400 6050-0010-1500 6050-0010-0800 6010-0010 OWS 208-0011 4107-1005 4107-1006 8 Zone Indicator Module •• •• An optional Zone Indicator module is available when more than one emergency zone is programmed and the user requires individual Zone Alarm, Alert, Evacuation and Fault indications The Zone Module also provides the ability to select and broadcast live speech to individual emergency zones Quiescent Current Zone Indicator Module Product Overview 10.5 mA 6010-0012 OWS The Ampac EvacU is a fully self-contained Occupant Warning System. Systems are available from 25W up to 200W and incorporate Ampac’s new range of Class “D” 25N & 50N Amplifiers, Control & Indicating modules and Line splitters. Up to eight Emergency zones and eight seperate Paging Zones can be configured using the dedicated EvacUwiz programming tool. •• •• •• •• •• •• •• •• •• •• Highly Efficient Class D Amplifier Technology Alert and Evacuation Signals to AS1670.1 Speaker Line Fault Monitoring and Protection Monitored Strobe Output Dedicated Emergency Microphone Input Secondary BGM and PA Analogue Audio Input False Alarm, System Test and Lock Down Messages Custom Messages Up to 8 Emergency Zones 8 Zone Remote Paging console 4 Way Line Splitter •• •• •• Quiescent Current 100V Line outs Monitoring EOL 4 Way Line Splitter Specifications Power Supply (General) Power Supply Battery Size Max (Battery box may be required) Cabinet Dimension (mm) Amplifiers Amplifiers (Audio) 25W (Max 4) 50W (Max 4) Amplifiers (Visual) Strobe Output Strobes Xenon Strobes LED Amplifiers Audio O/P Emergency Zones Front Controls (Max 1) www.ampac.net A four way Line splitter provides the ability to have a single emergency zone split into 4 separate monitored branches When a remote paging console is connected each split can be assigned to separate paging zones Up to two splitters can be connected to a single amplifier with a maximum of four splitters per system 3, 5 or 10Amps @ 24V 17 Ahr (depends on No. of Amplifiers fitted) 500(H) x 405(W) x 150(D) 10.5mA 4 (Max 100W each to a max of 250W total) 10K – 47K Ω 6010-0013 OWS 8 Zone Paging Console •• The Remote Paging Console allows up to 8 individual paging zones to be programmed when a combination of more than one amplifier and/or Line Splitters are included in the system Current Quiescent / Alarm 20 mA / 1.19 A each 20 mA / 2.39 A each •• 1A Max per Amplifier Max 8 sets Max 40 sets 100Vac Up to 8 max 10.5 mA Quiescent Number of Zones BGM Input Source Cable Cable Distance Additionally the RPC includes a back ground music input which can be programmed to each zone via the Remote Paging Console Quiescent Current 8 Zone Paging Console 5.5 mA 8 3.5mm Audio Jack CAT5 RJ45 connection 100m 6010-0014 OWS www.ampac.net 30 Alarm Systems 31 Occupant Warning System Add-Ons 120W OWS Product Overview The Ampac Single Zone Occupant Warning System is available with a 25 Watt and 50 Watt audio output with an optional front panel control. The alert and evacuation signals are compliant to AS1670.1 including voice messages as standard. The speaker circuit is protected and monitored for shorts and interruptions. Up to three spur lines (branches) are supported. A monitored strobe output is provided as standard which i supports both xenon and led strobes. Each audio source (alert / evacuation signals, emergency paging and secondary analogue audio input) has a dedicated volume control. Three programmable relays are provides, which default to fault, volume control override and test mode.The optional front panel control has an integrated emergency microphone (and can optionally support a hand held microphone) The Single Zone Occupant Warning System is suitable for use in Ampac’s FireFinder, LoopSense and ZoneSense Plus Fire Alarm Control Panels. •• •• •• •• •• •• •• •• •• •• Supply Voltage 27VDC (nominal) Max Audio Load 120Watt Quiescent Current (no audio load, no strobe load) 240mAmps Max. Current (full audio load, no strobe load) 8Amps Strobe Output (Xenon) 8 sets (208-0011) Strobe Output (LED) 40 sets (4107-1005/6) Audio output voltage 100VAC Temperature -20°C to 70°C Humidity 0-95% non-condensing Alert / Evac Changeover time (secs) Alert only, Evac only, 60, 90, 120, 180, 300 or under manual control Speaker EOL Nominal 47kΩ 5% 1/3 Watt THD<0.6% Signal to Noise Ratio 91dB Amplifier Dimension(L x W x H) 170mm x 210mm x 85mm OWS 120W Amplifier OWS Indicator & Controls vailable in 25Watt and 50Watt versions A Alert and Evacuation Signals to AS1670.1 Speaker Line Monitoring and Protection Monitored strobe output Volume Control Dedicated emergency microphone input Secondary analogue audio input Programmable evacuation strategies False Alarm, System test and Lock Down Messages Three programmable output relays 25 W& 50W OWS 25watt 250W OWS Supply Voltage 27VDC (nominal) Max Audio Load 250Watt Quiescent Current (no audio load, no strobe load) 380mAmps Max. Current (full audio load, no strobe load) 17 Strobe Output (Xenon) 8 sets (208-0011) Strobe Output (LED) 40 sets (4107-1005/6) Audio output voltage 100VAC Temperature -20°C to 70°C Humidity 0-95% non-condensing Alert / Evac Changeover time (secs) Alert only, Evac only, 60, 90, 120, 180, 300 or under manual control Speaker EOL Nominal 47kΩ 5% 1/3 Watt THD<0.6% Signal to Noise Ratio 91dB Amplifier Dimension(L x W x H) 300mm x 240mm x 95mm 50watt Max. Curret (full audio load, no strobe load) 1.19Amps 2.39Amps Supply Voltage 27VCD (nominal) Quiescent Current (no audio load, no strobe load)20mamps Strobe Output (Xenon) 8 sets (208-0011) Strobe Ouput (LED) 40 sets (4107-1005/6) Audio Output Voltage 100VAC Temperature -20° to +70° C Humidity 0-95% non-condensing Alert / Evac Changeover time (secs) Alert only, Evac only, 60, 90, 120, 180, 300 or under manual control Speaker EOL Nominal 47KΩ 5% 1/3 Watt THD 0.12% 0.89% Signal to Noise Ratio 80.5dB 82.1dB Alert Signal To AS1670.1 including voice Evacuate Signal To AS1670.1 including voice Amplifier (L x W x H) 100 x 77 x 35mm OWS 50W Amplifier OWS 25W Amplifier OWS Indicator & Controls www.ampac.net 6010-0004 6010-0003 6010-0001 6010-0002 6010-0003 OWS 250W Amplifier OWS Indicator & Controls 6010-0005 6010-0003 500w OWS Supply Voltage 240VAC/27VDC (nominal) Max Audio Load 500Watt Quiescent Current (no audio load, no strobe load) 500mAmps Max. Current (full audio load, no strobe load) 35Amps Strobe Output (Xenon) 8 sets (208-0011) Strobe Output (LED) 40 sets (4107-1005/6) Audio output voltage 100VAC Temperature -20°C to 70°C Humidity 0-95% non-condensing Alert / Evac Changeover time (secs) Alert only, Evac only, 60, 90, 120, 180, 300 or under manual control Speaker EOL Nominal 47kΩ 5% 1/3 Watt THD<0.5% Signal to Noise Ratio 90dB Amplifier Dimension(L x W x H) 83mm x 380mm x 88mm OWS 500W Amplifier OWS Indicator & Controls 6010-0006 6010-0003 www.ampac.net 32 Alarm Systems EV3000 Emergency Control Panel 33 Specifications Mechanical Material Finish Dimensions Approvals Signals 1.6mm Mild Steel Powder Coated Arch White 10U 700H x 625W x 240D mm (SECP only) 12U 900H x 650W x 290D mm 16U 1200H x 700W x 375D mm 29U 1800H x 700W x 375D mm SSL – AS2220.1 Compliant with AS1670.4:2004 Electrical Power Supply 7.5, 13, 19.5 or 26 A mps @ 24 VDC Communication RS485 @ 9600 bps EWS Zones 144 max EIS Zones 288 max Paging Console 8 max (recommended) ECP’s 12 max (recommended) Visual Warning Option 1EV3000 Visual Outputs Maximum of 8 pairs per visual circuit (for Xenon 208-0011). Not T3 compliant Option 2EV3000 Visual Outputs Maximum of 40 pairs per visual circuit (for LED 208-0063). T3 compliant Note: The LED visual pairs require the Ampac 4210-0031 Visual Driver Kit fitted Product Overview The Ampac EV3000 Occupant Warning and Intercom System is designed for the purpose of enabling the orderly evacuation of occupants, from a building or structure, in the event of an emergency. The system comprises of two (2) sub-systems. The first being the Occupant Warning System (OWS) and the other the Occupant Intercom System (OIS). While the Warning and Intercom System have separate controls, they coexist in a Apanel that is logically presented and aesthetically pleasing. The Occupant Warning System makes use of speakers strategically placed around the site, to broadcast ALERT, and/or EVACUATION signals or public address announcements. The OWS may be automatically initiated or manually operated. When not used in an emergency situation, the EV3000 can broadcast background music and/or general paging announcements. The Occupant Intercom System (OIS) consists of front panel control at the Emergency Control Panel (ECP) and Warden Intercom Phones (WIP) that are strategically placed throughout the building. Communication is only possible between the WIP and ECP. Item Numbers EV3000 12U 1 AMP RACK + FIRST EV3000 16U 1 AMP RACK + FIRST EV3000 29U 1 AMP RACK + FIRST EV3000 29U DBL CABINET 1 AMP EV3000 10U SECP C/W FIRST 8 EV3000 12U SECP C/W FIRST 8 EV3000 16U SECP C/W FIRST 8 EV3000 29U SECP C/W FIRST 8 105-0001 105-0002 105-0003 105-0007 105-0004 105-0005 105-0006 105-0009 For larger sites, multiple control panels may be networked. ABS (BX1) and Metal (BX10) cabinet versions. •• •• •• •• •• •• •• •• •• •• •• •• Network System Modular System Design. Discrete Front Panel Controls. 40, 120, 240 & 480 Watts Amplifiers to suit your need. Visual Output for Hearing Impaired or Noisy Environments. Common or Individual Fire Alarm Inputs. Common or Zoned Background Music Inputs. Monitoring of Speaker Circuits. Monitoring of Visual Warning Indicators. Automatic Volume Control incorporating Ambient Noise Sensing Microphone. Stand-by Signal Generators. Digital Paging Console www.ampac.net www.ampac.net 34 Alarm Systems 35 EV3000 Emergency Control Panel - Add Ons 40 Watt Power Amplifier 240 Watt Power Amplifier •• •• •• •• •• •• •• •• •• •• •• •• •• •• •• A modular power amplifier that is rated at 40 watts Multi-channel audio input supports Alert tone, Evacuation tone, Public Address, and background music Continuous monitoring of amplifier and 100 volt speaker circuit Overload protection with Automatic Easily plugs into an Ampac EV3000 amplifier frame Can fit up to 8 amplifiers per frame Voltage 24 VDC Quiescent current 58mA Max current 3400mA Max output power 40 Watts Output voltage 100 VAC RMS Freq. Response 150Hz to 12kHz (±1dB) Distortion Max 1% at full load (typical 0.5%) Sensitivity +5dB <200Kohm balanced) (1.4VRMS) Overload 100 VRMS + 10% Weight 675 grams 40 Watt Power Amplifier Voltage Quiescent current Max current Max output power Output voltage Freq. Response Distortion Signal to Noise Overload Weight 154-0075 120 Watt Power Amplifier •• •• •• •• •• •• A modular power amplifier that is rated at 120 watts Multi-channel audio input supports Alert tone, Evacuation tone, Public Address, and background music Continuous monitoring of amplifier and 100 volt speaker circuit Overload protection with Automatic Easily plugs into an Ampac EV3000 amplifier frame Can fit up to 4 amplifiers per frame Voltage Quiescent current Max current Max output power Output voltage Freq. Response Distortion Signal to Noise Overload Weight 120 Watt Power Amplifier 24v DC supply Mother board address strapping (120 address positions) Continuous fault monitoring Volume override output Test tone input Data selectable 4 channel input (balanced) Tone generator synchronisation input Indication (power on - green, power shutdown - yellow, amp or line fault - red, overload - red) Minimum cable size 2.5mm² 24 VDC 175mA 8100mA 120 Watts 100 VAC RMS 210Hz to 14.5kHz (±1dB) < 0.2% at full load 77 dB 100 VRMS + 10% 1160 grams 240 Watt Power Amplifier •• •• •• •• •• •• •• •• 24v DC supply Mother board address strapping (120 address positions) Continuous fault monitoring Volume override output Test tone input Data selectable 4 channel input (balanced) Tone generator Indication (power on - green, power shutdown - yellow, amp or line fault - red, overload - red) Minimum cable size 4mm² Voltage Quiescent current Max current Max output power Output voltage Freq. Response Distortion Signal to Noise Overload Weight 480 Watt Power Amplifier www.ampac.net 154-0001 480 Watt Power Amplifier •• 154-0077 24 VDC 350mA 16200mA 240 Watts 100 VAC RMS 210Hz to 14.5kHz (±1dB) < 0.2% at full load 77 dB 100 VRMS + 10% 2320 grams 24 VDC 700mA 32400mA 480 Watts 100 VAC RMS 210Hz to 14.5kHz (±1dB) < 0.2% at full load 77 dB 100 VRMS + 10% 4640 grams 154-0002 www.ampac.net 36 Alarm Systems 37 EV3000 Emergency Control Panel - Add Ons Emergency Alarm Intiating Device (EAID) Remote Paging Console •• •• •• •• •• •• Connects to S004 WIP 2 wires for WIP & EAID Compatible with 219-0015 Emergency Alarm Initiating Device (EAID) 213-0068 •• •• Provides a point to initiate a non-emergency voice announcement via the EV3000 Provides a pre-announcement tone Easy keypad operation to broadcast voice announcements to selected zones, or group of zones Connects to EV3000 via RS485 Derives power from the EV3000 panel Size Supply voltage Current Communication Weight Warden Intercom Phone- 2 Wire (S0004) •• •• •• •• Remote Paging Console 2 Wire WIP/EAID wiring High quality WIP audio Complies with AS4428.4 Suitable for models manufactured after July 2010 Operating Voltage Line Voltage Current draw Line Impedance Line Level Cabling Dimensions Weight 27 VDC (line driven) On hook - 25 VDC max Off hook - 14 VDC max On hook - 5 mA max Off hook - 35 mA max 360 ohm balanced 0 dB (± 3dB) 2 wire - 2.5mm² max. 215H x 85W x 62D mm 380 grams Warden Intercom Phone – 2 Wire (S0004) WIP Enclosure Metal Surface Mounted •• •• The fibre modem network interface kit offers the user a method of interconnecting two (2) or more EV3000 Emergency Warning and Intercom System (EWIS) using fibre optic cable as an alternative to copper. The modems convert hardwired data and audio, to a common fibre optic compatible output. 219-0015 291-0054 The fibre optic modems are full duplex and have 4-channels to carry both data and two (2) audio signals. Two (2) channels are required – emergency public address and warden intercom audio signals. Fibre Optic Network Interface for EV3000 EV3000 2 Core Single Mode Fibre Network Interface EV300 Single Core Multi Mode Fibre Network Interface EV300 Single Core Singe Mode Fibre Network Interface 154-0074 154-0271 154-0272 154-0273 The WIP is installed remote to the ECP Provides intercommunication between users at the WIP and Emergency Control Panel This feature is only available when the Emergency Warning Intercom facility has been incorporated in the control panel Made of high impact red ABS plastic Compatible with most EV3000 systems manufactured before July 2010 Operating Voltage Line Voltage Current draw Line Impedance Line Level Cabling Dimensions Weight Warden Intercom Phone – 3 Wire WIP Enclosure Metal Surface Mounted www.ampac.net 154-0005 Fibre Optic Network Interface for EV3000 Warden Intercom Phone - 3 Wire •• •• •• 80H x 300W x 220D mm 12 VDC 400 mA RS 485 1160 grams 27 VDC (line driven) On hook - 25 VDC max Off hook - 14 VDC max On hook - 5 mA max Off hook - 35 mA max 360 ohm balanced 0 dB (± 3dB) 3 wire - 2.5mm² max. 215H x 85W x 62D mm 380 grams 219-0007 291-0054 www.ampac.net 38 Graphics Package 39 Smart GraphicsHD Product Overview AMPAC’s SmartGraphicsHD System unleashes the full power of FireFinder (fire detection) and the EV3000 (alarm and intercom) by creating a robust and versatile hub for controlling your fire detection, alarm and intercom systems with one fully integrated package. Flexible and intuitive in its design, SmartGraphicsHD puts the command of your systems at your fingertips. •• •• •• •• •• •• •• •• •• •• •• Fire Status Indication Main Screen Interfaces to the FireFinder fire detection panel and the EV3000 emergency warning and intercom system Clearly shows on the building floor plan the start and spread of the fire and the status of the emergency warning and intercom system Has capabilities of e-mailing maps to emergency service organisations and key stakeholders Supports the latest 1920x1080 HD computer technology Able to operate over existing IT infrastructure Can be expanded to incorporate multi-site facilities into one central monitoring package Historic data log on the activity of the fire detection system and alarm system Three level password protection Detailed Egress Pathways Building Information (like hazardous materials) and mustering point displayed on maps Disable and Control Item Numbers SmartGraphics HD License Kit SmartGraphics HD PC System Complete SmartGraphics HD Touch PC System Complete USB-RS232 Converter Kit USB-RS485/422 Converter Kit SmartGraphics 19” Rack PC with Touch Screen 4100-0002 4100-0003 4100-0004 4100-0006 4100-0007 4100-0009 Access Map www.ampac.net History Page www.ampac.net 40 Detection & MCP’s 41 Series 65 Detection Series 65 Optical Smoke Detector The Series 65 Optical Smoke Detector incorporates a pulsing LED located within the housing of the detector. The external detector moulding is identical to that of the ionisation detector but has an indicator LED which is clear in quiescent state but produces red light in alarm. •• •• •• Responds well to slow-burning, smouldering fires Well suited for bedrooms and escape routes Unaffected by wind or atmospheric pressure Series 65 Optical Smoke Detector 4106-1001 Series 65 Ionisation Smoke Detector The Series 65 Ionisation Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm. •• •• Responds well to fast-burning, flaming fires Designed to operate in a variety of environments Series 65 Ionisation Smoke Detector 4106-1002 Series 65 Integrating Ionisation Smoke Detector Ionisation Detectors use a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm. Circuitry in the Ionisation Smoke Detector protects against transient levels of smoke above the normal threshold for up to 20 seconds. •• Responds well to fast-burning, flaming fires •• Designed to operate in environments where transient levels of smoke may be expected Product Overview Series 65 Integrating Ionisation Smoke Detector Series 65 incorporates well-proven sensing technologies together with advances in materials and electronics. Developed from the highly successful Series 60 range of detectors, Series 65 includes a chip (integrated circuit) based on that used in XP95 analogue addressable detectors. The range consists of ionisation, integrating ionisation and optical smoke detectors, four grades of heat detector and a range of bases. Series 65 Heat Detector •• •• •• •• •• •• •• •• •• Wide operating voltage Advanced electronic technology Flashing LED option Magnetic test switch option Can be used on security systems Electrically and mechanically compatible with Series 60 Proven detection performance Optical Ionisation Integrating Ion Operating voltage 9 to 33 V dc Quiescent current 50μA at 24 V dc Alarm current 52mA at 24 V dc Operating temp (no icing) -20°C to +60°C Relative humidity 100mm Height 50mm Weight inc base IP Rating Approvals 150 grams 15 grams 131 grams IP23D (EN60529) AS240-7 Can be used for applications where smoke detectors are unsuitable Ideal in environments that are dirty or smoky under normal conditions Series 65 A1R Standard Rate-of-Rise – MAT 50°C, MSRT 65°C Series 65 BR Standard Rate-of-Rise – MAT 65°C, MSRT 85°C Series 65 CR Standard Rate-of-Rise – MAT 80°C, MSRT 100°C Series 65 CS Standard Static – MAT 80°C, MSRT 100°C AS240-5 The Series 65 Standard Base has been designed to enable detectors to be fitted without the need for force – particularly useful when fitting to suspended ceilings. All Series 65 bases have a one way fit and can be locked into place by a grub screw using a 1.5mm hexagonal screwdriver. •• •• •• •• •• Detector locking mechanism One way fit Easy to wire Contains an earth connector Contains no electrical parts Series 65 Standard Base www.ampac.net 4106-1004 4106-1005 4106-1006 4106-1007 Series 65 Standard Base -20°C to +90°C 153 grams The Series 65 Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are four classes of heat detectors in the Series 65 range designed to suit a wide variety of operating conditions. Heat 0 to 95% (non condensing) Diameter 4106-1003 4106-1008 www.ampac.net 42 Detection & MCP’s 43 Heat Detection Orbis Detection Type E Detector Type E Detector The Type E Heat Detector is a thermal sensitive switch. It is a fixed temperature device with a factory pre-set temperature in the range 60 °C to 240 °C. The detectorcomprises a pair of normally open electrical contacts mounted within a stainless steel Probe •• •• •• •• •• Resetting Type Heat Detector Rate Compensation & Fast Response Wide Temperature Range Gold Plated Electrical Contacts Corrosion & Shock Resistant Contacts Operating Current Applied Voltage DC at 0.25A Operating Temp Set-point Ambient Temp Range IP rating Weight Sensitivity & Accuracy Approvals Normally open, close on temp set-point 0.25 A max 32 V max +60°C to +240°C -40°C to +180°C IP67 140 grams +/- 5% or degrees AS1603-1 (CSIRO) Type E Heat Detector Dual Thread Type E Heat Detector Single Thread 223-0002 223-0003 Product Overview Thermal Type B Sealed Cool Room Detector (Hoc) The conventional Type B Cool Room Heat Detector is a 60°C fixed temperature waterproof detector. The detector uses a bi-metallic strip to sense temperature change,therefore consuming minimal standby current and providing high reliability. •• •• •• •• Waterproof Design – rated to IP67 No Mounting Base Required Low Current Consumption CSIRO Approved to AS1603.1 Operating Voltage 15 to 30 V dc (Nominal 24 V dc) Max Alarm Current 50 mA at 24 V dc Remote LED Current 4mA at 5V Dimensions 98 mm Dia x 45 mm H Operating temperature -10°C to +40°C ColourIvory IP rating IP67 Weight 80 grams ApprovalsAS1603-1 Type B Cool Room Heat Detector 202-0023 Orbis is a range of conventional detectors which has been developed with sophisticated technology previously only found in intelligent detectors. Orbis is a range with modern styling and incorporates a mounting base wihich saves installation time. •• •• •• •• •• •• •• •• •• •• •• Automatic drift compensation with DirtAlert® warning Patented FasTest® which reduces the time taken to test detectors SensAlert® uses a flashing LED to indicate that the sensor is not operating correctly StartUpTM for fast commissioning Attractive and compact design Electrically compatible with Series 60 and Series 65 Wide voltage and operating temperature ranges Algorithms for transient rejection Flashing LED option 360° visibility of LEDs Insect resistant Optical Multisensor Operating voltage 8.5 to 33 V dc Quiescent current 95μA at 24 V dc Alarm current 40mA at 24 V dc Operating temp -40°C to +70°C (no icing) Relative humidity 0 to 98% (non condensing) Diameter 97mm Height inc base 46mm 57mm 51mm Weight inc base 135 grams 140 grams 130 grams IP Rating Approvals www.ampac.net Heat IP23D (EN60529) AS7240-7 AS7240-5 www.ampac.net 44 Detection & MCP’s 45 Orbis Detection Manual Call Points Optical Smoke Detector Manual Call Point – ACP-04 The Orbis Optical Smoke Detector works using the well established light scatter principle, however, the sensing technology is radically different in design from previous optical detectors and significantly reduces false alarms. •• •• •• •• •• •• •• •• Current Rating Size Switch Type Cable termination In-Line Resistor Material Operating Temperature Humidity IP rating Weight Responds well to slow-burning, smouldering fires Performs well in black and white smoke Extra confirmation of smoke before alarm signal is given Reduced incidence of false alarms Sensing chamber keeps out dust and other airborne contaminants Operates over a broad range of voltages at extremes of temperature Orbis Optical Smoke Detector 4106-1051 Multisensor Smoke Detector The Orbis Multisensor Detector benefits from the same false alarm reduction technology as the optical detector. It is a thermally enhanced smoke detector and so will not give an alarm from heat alone. •• •• •• •• •• •• Responds well to slow-burning, smouldering fires Performs well in black and white smoke Extra confirmation of smoke before alarm signal is given Reduced incidence of false alarms Sensing chamber keeps out dust and other airborne contaminants Operates over a broad range of voltages at extremes of temperature Orbis Multisensor Detector 4106-1052 Heat Detector The Orbis Heat Detector monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. There are seven classes of heat detectors in the Orbis range designed to suit a wide variety of operating conditions. •• •• •• •• Can be used for applications where smoke detectors are unsuitable Ideal in environments that are dirty or smoky under normal conditions Reduced incidence of false alarms Increased reliability of detection Orbis A1R (50°C) Heat Detector Rate of Rise Orbis A2S (50°C) Heat Detector (Type B) Static Orbis BR (65°C) Heat Detector (Type A) Rate of Rise Orbis BS (65°C) Heat Detector Static Orbis CR (80°C) Heat Detector (Type C) Rate of Rise Orbis CS (80°C) Heat Detector (Type D) Static 4106-1053 4106-1054 4106-1055 4106-1056 4106-1057 4106-1058 Orbis TimeSaver Relay Base To support the Orbis detectors a range of bases are available. Each base has two slots for fixing screws at a spacing of 51mm to 69mm. The detectors fit into the base one way only and require minimal force in a clockwise rotation. The TimeSaver Relay base incorporates a single pole voltage-free changeover contact for switching external equipment. The relay is energised when the detector changes to alarm state and deactivates when the detector is reset. The relay is capable of switching up to 30V at 1A. The Orbis Adaptor base enables the detector to be fitted to a Series 60/65 base. Orbis LX Base Orbis TimeSaver Relay Base Orbis Adaptor Base www.ampac.net 201-0545 201-0543 201-0544 Double terminal, wire protected connectors for independent input and output connections when looping to other devices Protective film prevents glass from splintering when broken 3A @ 12/24 VDC 1.5A @ 48 VDC 88mm H x 88mm W x 59mm D (surface) 88mm H x 88mm W x 27mm D (flush) Single pole micro 6 x 2.5mm2 screw 470Ω (N/O operation only) High impact ABS -5°C to +70°C 0 – 95% non-condensing IP 24D (indoor use) 153 grams Manual Call Point – ACP-04 Red Manual Call Point – ACP-04 Yellow Manual Call Point – ACP-04 White Manual Call Point – ACP-04 Green Manual Call Point – ACP-04 Protective Cover Manual Call Point – ACP-04 Glass 213-0060 213-0061 213-0062 213-0063 213-0057 213-0058 Manual Call Point – Conventional Weatherproof The Weatherproof Manual Call Point has been designed for use outdoors and in places where moisture may be present. The Manual Call Point provides a simple single pole changeover contact for use with older fire systems or in other applications requiring switching at up to mains voltage. Contact rating 3A at 24 VDC Size 87mm H x 87mm W x 57mm D Switch type Single Pole Material High Impact ABS Temperature range -25°C to +70°C IP rating IP65 Weight220g IP65 MCP Reset n/c n/o con 213-0045 Manual Call Point - Conventional Waterproof The Conventional Waterproof Manual Call Point has been designed to work on conventional systems. The Manual Call Point has an easilt resettalbe element rather than a break glass. Supply Voltage Operatin Temperature Humidity (No condensation or icing) IP Rating Alarm Resistance Current (Alarm LED On) Conventional Waterproof MCP 9-33VDC -30o to 70o 0-95% 67 470-680 Ohms 80mA 4105-1002 www.ampac.net 46 Detection & MCP’s 47 Sampling Duct Units Beam Detection Product Overview The FIRERAY 5000 motorised reflective, auto aligning infrared optical beam smoke detector can be installed with up to two detector heads per system, thus saving on installation time and costs. In addition, each system controller houses two pairs of fire and fault relays, one per detector. This innovative system has been designed from the ground up to include pioneering technology that fully addresses the needs of the installer and user, both now and in the future. Product Overview The Ampac Duct Sampling Unit is designed to monitor levels of smoke in air ducts operating in air speeds of 0.5 to 20 meters per second. The duct smoke detector can be fitted to any wall of a ventilation duct and has two tubes that extend into the duct through punched holes. The perforated sampling tube is placed in the airflow upstream of the exhaust tube which causes a pressure differential in the duct detector. Air is sucked up the sampling tube, across the detector and exhausted back into the air duct. Using the 360mm sampling pipe supplied, an air duct of up to 560mm can be monitored. For duct widths greater than 560mm, three other lengths of sampling pipe are available. •• •• •• •• •• •• •• •• Both sampling and exhaust pipes are fitted to the back box without the need for tools making installation easier The cover of the duct smoke detector is monitored to ensure working integrity and if removed, causes a fault to appear at the fire alarm control panel Easily accessible wire clamping terminals ensure secure and fast termination Clear cover hence the alarm LED on the detector is visible at all times Integral smoke test port Sampling pipes available in 4 lengths Operates in air speeds of 0.5 m/s to 20 m/s Volt free contacts www.ampac.net Allows for 2 Detectors per System Controller Each Detector configurable from 8m to 100m Separate Fire and Fault relays per Detector Integral LASER alignment Auto-Align Fast Automatic Beam Alignment Building Movement and Contamination Compensation Low Level System Controller Logs the 50 most recent events per detector Programmable Sensitivity and Fire Thresholds 20mm Cable Gland Knockouts on System Controller 2-wire interface from System Controller to Detector Operating distance (separation) Cable length – system controller to detector Operating voltage (to system controller) 8-100 metres 100 metres 14VDC to 36VDC Operating current with 1 detector 5 to 6 mA Operating current with 2 detectors 7.5 to 8.5 mA Operating temperature Relative humidity IP rating -10°C to +55°C (no icing) 93% (non condensing) IP54 Item Numbers Item Numbers Orbis Duct Sampling Unit inc Detector Base Duct Probe 300mm to 750mm Duct Probe 750mm to 1500mm Duct Probe 1500mm to 3000mm •• •• •• •• •• •• •• •• •• •• •• 214-0052 214-0060 214-0061 214-0062 Reflective Beam System Reflective Prism Detector & Reflective Prism Long Range Reflective Prism Universal Bracket for Detector Prism Plate (1) Prism Plate (4) Ceiling Pendant Mounting Detector Protective Cage 4109-1003 220-0007 220-0009 220-0010 220-0011 220-0012 220-0013 220-0014 220-0015 www.ampac.net 48 Detection & MCP’s 49 XP95 Detection XP95 Optical Smoke Detector The XP95 Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely. ® •• •• •• Responds well to slow-burning, smouldering fires Well suited for bedrooms and escape routes Unaffected by wind or atmospheric pressure XP95 Optical Smoke Detector XP95 Optical (Black) Smoke 4106-2001 4106-2010 XP95 Ionisation Smoke Detector The XP95 Ionisation Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm. •• •• •• •• Responds well to fast-burning, flaming fires Designed to operate in a variety of environments Minimal effects from temperature, humidity, atmospheric pressure Well protected against electromagnetic interference over a wide frequency range XP95 Ionisation Smoke Detector XP95 Ionisation (Black) 4106-2002 4106-2011 Product Overview The XP95 range of intelligent fire detectors is advanced in design, improved in performance and has unique features that benefit the installer and end user. The range features smoke detectors (ionisation and optical), standard and high temperature heat detectors and a multisensor. Beam detectors, flame detectors, manual call points, audio visual signalling devices, interface units and isolators complete the range. XP95 has a ‘central intelligence’ system where all the decisions are made by the control panel. •• •• •• •• •• •• •• Alarm Flag for fast alarm reporting Alarm Address for fast location of alarm XPERT card addressing Electronics-free base Easy installation Elegant design Insect Resistant Optical Alarm current at 24 V dc Operating temp (no icing) Ionisation Heat 280μA 250μA 500μA 4mA 2mA 2mA 3.5mA -20°C to +60°C -20°C to +70°C -20°C to +70°C XP95 Multisensor Detector 100mm 50mm 157 grams 161 grams 58mm 161 grams 150 grams 160 grams IP23D (EN60529) AS7240-5 - The XP95 Multisensor Detector contains an optical smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analogue value. •• •• •• Sensitive to a wide range of fires Well suited for environments such as hotel bedrooms Unaffected by wind or atmospheric pressure XP95 Multisensor Detector www.ampac.net 4106-2003 4106-2013 -20°C to +60°C 0 to 95% (non condensing) Height Approvals -20°C to +120°C Ideal in environments that are dirty or smoky under normal conditions Well suited for warehouses, loading bays and car parks Unaffected by wind or atmospheric pressure XP95 Heat Detector Standard – A2S XP95 Heat A2S (Black) Detector Multisensor 340μA Diameter IP Rating High Heat 17 to 28 V dc Relative humidity Weight inc base The XP95 Heat Detector monitors temperature by using a single thermistor network which provides a count output proportional to the external air temperature. The XP95 range features two Heat Detectors, standard and high temperature. The standard heat detector is classified as an A2S device and will report an alarm at 55°C. The high temperature detector, classified as a CS device, will report an alarm at 90°C. •• •• •• Operating voltage Quiescent current at 24 V dc XP95 Heat Detector 4106-2004 www.ampac.net 50 Detection & MCP’s 51 Discovery Detection Discovery Optical Smoke Detector The Discovery Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely. •• •• •• •• Responds well to slow-burning, smouldering fires Well suited for bedrooms and escape routes Unaffected by wind or atmospheric pressure Remote test feature Discovery Optical Smoke Detector 4106-2005 Discovery Multisensor Detector The Discovery Multisensor Detector comprises optical smoke and thermistor temperature sensors whose respective outputs can be split to deliver specific smoke or thermal actions respectively. This capability can aid early Alarm warning routines and other advanced detection techniques. Discovery Multisensor Detector Discovery Multisensor (Black) 4106-2008 4106-2012 Discovery Ionisation Smoke Detector The Discovery Ionisation Smoke Detector uses a low activity radioactive foil to irradiate the air in the smoke chamber causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm. Product Overview Discovery is a range of high-specification, intelligent fire detectors developed to meet the requirements of sophisticated systems while providing engineers with an additional dimension in fire protection capability. Discovery has a ‘distributed intelligence system’ where decisions are made in the detector head as well as at the control panel. Drift compensation is also incorporated into the detector, allowing it to adapt to dirty or dusty environments reducing false alarms. •• •• •• •• •• •• •• •• •• •• Optical/Heat Multisensor Operating voltage Quiescent current 24 V dc 300μA 400μA -40°C to +70°C 58mm Weight inc base Discovery CO/Heat Multisensor Detector 400μA -30°C to +70°C 50mm 300μA -20°C to +55°C 60mm 50mm - - IP44 (EN60529) AS7240-7 AS7240-5 AS7240-7 4106-2007 Carbon Monoxide 160 grams IP Rating www.ampac.net CO/Heat Multisensor 100mm 50mm 4106-2006 Ideal in environments that are dirty or smokey under normal conditions Well suited for warehouses, loading bays and car parks Unaffected by wind or atmospheric pressure Remote test feature Discovery Heat Detector 0 to 95% (non condensing) Diameter Approvals •• •• •• •• 3.5mA Relative humidity Height inc base 300μA Discovery Ionisation Smoke Detector The Discovery Heat Detector, distinguishable by the low airflow resistant case, uses a single thermistor to sense the air temperature around the detector. 17 to 28 V dc Alarm current 24 V dc Operating temp (no icing) Ionisation Responds well to fast-burning, flaming fires Designed to operate in a variety of environments Remote test feature Discovery Heat Detector Rejection of transient signals Flashing LED option Five response modes for ease of optimisation to changing environments Drift compensation to ensure constant sensitivity Four bytes of non-volatile memory for user data Alarm flag for fast alarm reporting Conventional alarm facility during control panel processor fault 360° visibility in alarm Compatible with XP95 systems Insect resistant Optical •• •• •• The Discovery CO/Heat Multisensor Detector is good at detecting deepseated smouldering fires which give off a lot of CO as well as flaming fires. They are ideal for use in hotel bedrooms where steam may be present, dusty environments or even where simulated smoke may be present. •• •• •• •• •• Enhanced detection capability Early response to hot fires Ideal for smouldering fires Less susceptible to false alarms caused by steam than smoke alarms Five response modes Discovery CO/Heat Multisensor Detector 4106-2009 www.ampac.net 52 Detection & MCP’s 53 Discovery Detection Manual Call Points Discovery Carbon Monoxide Detector Intelligent Manual Call Point (New) The Discovery Carbon Monoxide (CO) Detector is good at detecting deep-seated fires. Please note that CO detectors do not detect smoke particles or heat and are not universal replacements for smoke detectors. The Intelligent Manual Call Point has a highly visible alarm indicator which can be seen from up to 10 metres away. When activated, the manual call point interrupts the polling cycle for a fast response. A combined LED indicator and front reset mechanism allows for a quick and simple reset. •• •• •• •• •• Enhanced detection capability Early response to hot fires Ideal for smouldering fires Less susceptible to false alarms caused by steam than smoke alarms Five response modes Discovery Carbon Monoxide Detector 201-0102 All detectors in the XP95 range fit the Intelligent Detector Base. It is a low insertion force base with stainless steel contacts for the detector terminals. XPERT addressing One way fit of detector Locking feature to prevent unauthorised removal XP95/Discovery Detector Base XP95/Discovery Detector Base (Black) 201-0004 201-0093 XP95/Discovery Isolating Base The new style Isolating Base senses and detects short-circuit faults on XP95 loops and spurs. •• •• Up to 20 devices may be installed between isolating bases High brightness LED XP95/Discovery Isolating Base 201-0125 The Low Power Relay Base incorporates a low power relay to control field equipment such as automatic door closers. Gives a set of voltage free contacts controlled by the remote output of a detector Draws negligible current Capable of switching up to 30V at 1A XP95/Discovery Low Power Relay www.ampac.net 4105-2005 4105-2003 4105-2004 Waterproof Manual Call Point (New) The Waterproof Addressable Manual Call Point has a highly visible alarm indicator which can be seen from up to 10 metres away. When activated, the manual call point interrupts the polling cycle for a fast response and has a combined LED indicator and front reset mechanism allowing for a quick and simple reset. Voltage Quiescent current Alarm current Size (surface mount) Operating temperature Relative humidity IP rating Weight Waterproof Manual Call Point Transparent Cover Pack of 10 Reset Keys 17-28 VDC 100μA 4mA 110H x 110W x 74D mm -30°C to +70°C 0-95% RH IP67 180 grams 4105-2002 4105-2003 4105-2004 Addressable XP95 Manual Call Point XP95/Discovery Intelligent Low Power Relay Base •• •• •• 17-28 VDC 100μA 4mA 87H x 87W x 54D mm -40°C to +70°C 0-95% RH 45 180 grams Inetlligent Manual Call Point with Isolator Transparent Cover Pack of 10 Reset Keys XP95/Discovery Intelligent Detector Base •• •• •• Voltage Quiescent current Alarm current Dimensions (surface mount) Operating temperature Humidity IP rating Weight 201-0014 The XP95 Manual Call Point has been designed to operate on a loop of intelligent addressable fire detection devices. The address of each call point is set at the commissioning stage by means of a seven segment DIL switch. The device features plug and play terminal connections and a resettable element. Voltage Quiescent current Alarm current Address method Size (surface mount) Operating temperature Relative humidity IP rating Weight XP95 Manual Call Point (Surface) XP95 Manual Call Point Protective Cover Intelligent Waterproof Manual Call Point 17-28 VDC 100μA at 24VDC 4mA 7 segment DIL switch 93mm H x 89mm W x 59.5mm D -20°C to +60°C (no icing) 0-95% (non condensing) IP24D (indoor use) 160 grams 213-0050 213-0064 213-0066 www.ampac.net 54 Detection & MCP’s 55 Duct Sampling Unit Flame Detection Product Overview Product Overview The Ampac Duct Sampling Unit is designed to monitor levels of smoke in air ducts operating in air speeds of 0.5 to 20 meters per second. The duct smoke detector can be fitted to any wall of a ventilation duct and has two tubes that extend into the duct through punched holes. The perforated sampling tube is placed in the airflow upstream of the exhaust tube which causes a pressure differential in the duct detector. Air is sucked up the sampling tube, across the detector and exhausted back into the air duct. Using the 360mm sampling pipe supplied, an air duct of up to 560mm can be monitored. For duct widths greater than 560mm, three other lengths of sampling pipe are available. •• •• •• •• •• •• •• •• Both sampling and exhaust pipes are fitted to the back box without the need for tools making installation easier The cover of the duct smoke detector is monitored to ensure working integrity and if removed, causes a fault to appear at the fire alarm control panel Easily accessible wire clamping terminals ensure secure and fast termination Clear cover hence the alarm LED on the detector is visible at all times Integral smoke test port Sampling pipes available in 4 lengths Operates in air speeds of 0.5 m/s to 20 m/s Volt free contacts Item Numbers Duct Sampling Unit inc XP95 Detector Base Duct Probe 300mm to 750mm Duct Probe 750mm to 1500mm Duct Probe 1500mm to 3000mm www.ampac.net 214-0051 214-0060 214-0061 214-0062 Flame detectors are effective in protecting areas where flaming fires may be expected. There is a choice of detection techniques - Ultra Violet and Infra-red, or a combination of both. UV Flame Detectors are generally used in engine rooms, factories and warehouse applications. Infra-red Flame Detectors are able to tolerate dirtier environments which may block UV radiation and are generally used in applications such as waste handling, colour printing and paper manufacturing. •• •• •• •• •• •• Detects a wide range of open fires Insensitive to wind Transient voltage protection Three types of detector Lockable security fitting White finish UV Base IR2 Base IR3 Base Operating voltage Quiescent current at 24 V dc Field of view Operating temp (no icing) IR3 Flame 17-28 V DC 2.3mA 2.8mA 2.2mA 2.2mA 2.2mA 90° cone 90° cone 90° cone 90° 90° -40°C to +55°C Relative humidity Dimensions IR2 Flame -10°C to +55°C 0 to 95% (non condensing) 100D x 48H mm Weight 210g IP Rating IP66 142W x 108H x 82D mm 1 kg 2 kg IP65 www.ampac.net 56 Detection & MCP’s 57 Flame Detection Intelligent Base Mounted UV Flame Detector Intelligent Dual IR Flame Detector The Intelligent Base Mounted UV Flame Detector is designed to protect internal areas where open fires may be expected. The detector has a single UV sensor with a narrow spectral response in order to discriminate between flames and most spurious sources of radiation. The Intelligent Dual Infra-Red (IR²) Flame Detector is designed for use in areas where flaming fires may be expected. The detector has two sensors which respond to different IR wavelengths to discriminate between flames and spurious sources of radiation. Applications include aircraft hangars, coal handling and paper manufacturing plants and woodworking environments. •• •• •• •• •• Responds to stationary flames with no flicker Sensitive to UV radiation emitted by flames during combustion Compact flame detector which can fit into Discovery or XP95 bases Loop-powered Increased reliability of detection XP95 Base Mounted UV Flame Detector XP95 Dual IR2 Flame Detector 201-0130 201-0169 Intelligent Triple IR Flame Detector The Intelligent Triple IR Flame Detector (IR³) is designed to protect areas where open flaming fires may be expected. It is sensitive to low frequency, flickering infra-red radiation emitted by flames during combustion. XP95 Triple IR3 Flame 201-0188 Intelligent Base Mounted UV IR² Flame Detector The Intelligent Base Mounted UV IR² Flame Detector is designed to protect areas where open flaming fires may be expected. The detector has a UV and dual IR sensors responding to different wavelengths in order to discriminate between flames and spurious sources of radiation. •• Responds to stationary flames with no flicker •• Sensitive to UV and low-frequency flickering IR radiation emitted by flames during combustion •• Compact flame detector which can fit into Discovery or XP95 bases •• Loop-powered •• False alarms due to electrical discharges from lightning or arc welding and flickering sunlight are minimised XP95 Base Mounted UV IR² Flame Detector Base Mounted Flame Detector Bracket The Flame Detector Bracket is an optional accessory for the Intelligent Flame Detectors. It is a stainless steel mounting bracket adjustable in two axis. Bracket for Base Mounted Flame Detectors 201-0186 201-0131 Flame Detector Bracket The Flame Detector Bracket is an optional accessory for the Intelligent Flame Detectors. It is a stainless steel mounting bracket adjustable in two axis. Not suitable for Base Mounted Flame Detectors. Flame Detector Bracket Intelligent Base Mounted IR³ Flame Detector 201-0189 The Intelligent Base Mounted IR³ Flame Detector is designed to protect areas where open flaming fires may be expected. The detector has three IR sensors that respond to different IR wavelengths in order to discriminate between flames and spurious sources of radiation. •• Responds to stationary flames with no flicker. •• Sensitive to low-frequency flickering IR radiation emitted by flames during combustion. •• Compact flame detector which can fit into Discovery or XP95 bases. •• Loop-powered. •• False alarms due to factors such as flickering sunlight are avoided by a combination of filters and signal processing techniques. XP95 Flameproof IR³ Flame Detector www.ampac.net Flame Detector Weather Shield The Flame Detector Weather Shield protects the device from inclement conditions. S/Steel Weather Shield for Standard Flame Detector 201-0190 201-0132 www.ampac.net 58 Detection & MCP’s 59 Hazardous Area Detection Orbis I.S. Optical Smoke Detector The Orbis I.S. Optical Smoke Detector works using the light scatter principle, and is ideal for applications where slow burning or smouldering fires are likely. ® TM •• •• •• •• •• Reduces false alarms Recommended for early warning of fire in most areas Improved sensitivity to black smoke Compensation for slow changes in sensitivity Algorithms for reliability of alarm Orbis I.S. Optical Smoke Detector 201-0604 Orbis I.S. Multisensor Detector The Orbis I.S. Multisensor Detector benefits from the same false alarm reduction technology as the optical detector. It is a thermally enhanced smoke detector and so will not give an alarm from heat alone. •• •• •• •• •• Reduces false alarms Sensitive to fast burning, flaming fires Improved sensitivity to black smoke Compensation for slow changes in sensitivity Algorithms for reliability of alarm Orbis I.S. Multisensor Detector 201-0605 Orbis I.S. Heat Detector Product Overview Ampac offers a range of Intrinsically Safe detectors in both conventional and addressable. Orbis IS ia a range with modern styling and is electronically compatible with Apollo Series 60 intrinsically safe conventional detectors. XP95 Intrinsically Safe range is a development of the well established intelligent XP95 range from Apollo specifically for use in hazardous areas and are set by means of the patented XPERT card. Optical Operating voltage Quiescent current 24 V dc •• •• •• •• 340μA 300μA 300μA 20°C to +60°C (no icing) Relative humidity 0 to 95% (non condensing) Dimensions inc base Can be used for applications where smoke detectors are unsuitable Ideal in environments that are dirty or smoky under normal conditions Reduced incidences of false alarms Increased reliability of detection Orbis I.S. A1R Heat Detector- Rate of Rise Orbis I.S. A1S Heat Detector- Static Orbis I.S. A2S Heat Detector- Static Orbis I.S. BR Heat Detector- Rate of Rise Orbis I.S. BS Heat Detector- Static Orbis I.S. CR Heat Detector- Rate of Rise Orbis I.S. CS Heat Detector- Static Heat 14 to 22 V dc Operating temp range Weight inc base Ionisation The Orbis IS Heat Detector monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. There are seven classes of heat detectors in the Orbis IS range designed to suit a wide variety of operating conditions. 100Dia x 50H mm 157 grams 161 grams IP Rating IP23D (EN60529) Category II IG Ex ia IIC T5 -20°C≤Ta≤45°C (T4≤60°C) Ga Certificate IECEx BAS 12.0091X, BAS02ATEX 1289 161 grams Orbis I.S. TimeSaver Base The Orbis IS TimeSaver Base is a completely new design that provides installers with an open working area with fixing holes shaped to allow a simple mounting procedure. •• •• •• •• Grouped terminals to make wiring easy Two fixing centres LED alignment mark Detector locking mechanism Orbis I.S. TimeSaver Base www.ampac.net 201-0134 201-0135 201-0601 201-0600 201-0607 201-0602 201-0603 201-0606 www.ampac.net 60 Detection & MCP’s 61 Hazardous Area Detection XP95 I.S. Ionisation Smoke Detector Conventional Galvanic Barrier The XP95 I.S. Ionisation Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm. The Conventional Galvanic Barrier is installed in the safe area and ensures system integrity •• •• •• •• •• •• •• Detects super heating and flaming combustibles Dual chamber technology Wind resistant smoke inlets. Transient voltage protection Fine gauze insect protection Lockable security fitting Must be connected to a suitable safety barrier and protocol translator XP95 I.S. Ionisation Smoke Detector 201-0103 The XP95 I.S. Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely. Detects a wide range of fires Insensitive to wind Transient voltage protection Fine gauze insect protection Simple construction allows detection chamber to be cleaned Lockable security fitting Must be connected to a suitable safety barrier and protocol translator XP95 I.S. Optical Smoke Detector Supply Voltage 30V DC Dimensions 93mm H x 89mm W x 59.5mm D MaterialABS 4105-3014 Conventional Intrinsically Safe Call Points 201-0104 The XP95 I.S. Heat Detector operates by measuring heat levels with a single thermistor network which gives a count output proportional to the external air temperature. Rate of rise and fixed temperature alarm point Single thermistor technology Transient voltage protection Resettable operation Lockable security fitting Must be connected to a suitable safety barrier and protocol translator XP95 I.S. Heat Detector The conventional IS manuall call point has been designed to aperate on contenctional instrinsically safe fire detection systems. designed specifically for use in atmospheres which explosivemixures are or may be present. Conventional Indoor I.S. MCP Red (470 ohm) XP95 I.S. Heat Detector •• •• •• •• •• •• 201-1061 201-0198 Conventional Indoor I.S. MCP Red (470 ohm) XP95 I.S. Optical Smoke Detector •• •• •• •• •• •• •• Orbis I.S. Galvanic Barrier Singel Channel Orbis I.S. Galvanic Barrier Dual Channel 201-0105 XP95 I.S. Mounting Base The range of conventional manual call points include break glass, push button and tool reset versions which are approved for Zone 0, 1, 2, 21 and 22 requiring intrinsically safe equipment for the control of fire and gas alarm systems Supply Voltage Dimensions Material Aluminium IP Rating Approvals IS Break Glass Call Point, Red IS Push Button Call Point, Red IS Tool Reset Call Point, Red I.S. Break Glass Call Point I.S. Push Button Call Point I.S. Tool Reset Call Point 24V DC (28 max) 98mm H x 95mm W x 76mm D Marine grade copper free LM6 IP66 ATEX, IECEx, Inmetro, GOST-R 4105-3007 4105-3008 4105-3009 4105-3010 4105-3011 4105-3012 The XP95 I.S. Mounting Base has been designed to accept only IS products. This ensures that standard detectors cannot inadvertently be fitted into an intrinsically safe system. XPERT cards are supplied with all bases. •• •• •• •• •• •• •• •• Wide cable entry Contains no electronic parts ‘One way only’ fit Low insertion force Large terminations Lockable security fitting White finish. Must be connected to a suitable safety barrier and protocol translator XP95 I.S. Mounting Base www.ampac.net 201-0106 www.ampac.net 62 Detection & MCP’s 63 Hazardous Area Detection IP65 I.S. Manual Call Points Conventional BEx Flameproof Call Points The XP95 IS Manual Call Point is based on the standard weatherproof model. It features an ‘interrupt’ facility to provide fast response to an alarm. The range of conventional manual call points include break glass, push button and tool reset versions which are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems. Voltage 14 to 22 VDC Quiescent current 300uA Alarm current 2mA (alarm LED On) Size 124mm H x 124mm W x 60mm D Operating temperature –20°C to +40°C (T5) –20°C to +60°C (T4) Humidity 0 to 95% IP rating IP67 Weight 400 grams Classification E Ex ia IIc T5 ApprovalsEN54-11 XP95 Intrinsically Safe Manual Call Point Supply Voltage 24V DC (28 max) Dimensions 98mm H x 95mm W x 76mm D Material Marine grade copper free LM6 Aluminium Colour Red (RAL3000) Operating Temperature Ta = -40°C to +50°C IP Rating IP66 Weight800g Approvals ATEX, IECEx, GOST-R BEx Break Glass Call Point, Red, 470R Fire, 3K3 EOL BEx Push Button Call Point, Red, 470R Fire, 3K3 EOL BEx Tool Reset Call Point, Red ,470R Fire, 3K3 EOL BEx Break Glass Call Point, Red, 470R Fire BEx Push Button Call Point, Red, 470R Fire BEx Tool Reset Call Point, Red, 470R Fire BEx Push Button Call Point, Yellow, 470R Fire, 3K3 EOL 201-0107 XP95 I.S. Protocol Translator and Galvanic Barrier The Protocol Translator and Galvanic Barrier are installed in the safe area ensuring integrity of communication between control equipment and field devices and safety within the limits of BASEEFA approvals •• •• •• •• •• Enables IS detectors to be connected to a standard loop driver Loop powered DIN-Rail mounting Maximum of 20 XP95 IS devices per channel Translators must be connected to detectors via a suitable safety barrier XP95 Protocol Translator Single Channel XP95 Protocol Translator Dual Channel XP95 I.S. Galvanic Barrier 4105-3001 4105-3002 4105-3003 4105-3004 4105-3005 4105-3006 4105-3013 Intelligent Flameproof Triple IR Flame Detector The Intelligent Triple IR Flame Detector (IR³) is designed to protect areas where open flaming fires may be expected. It is sensitive to low frequency, flickering infra-red radiation emitted by flames during combustion. 201-0108 201-0155 201-0109 •• •• •• •• •• •• Loop-powered Sensitive to flickering IR radiation Detects through films of oil, dust, water and ice Responds to flickering flames, including those invisible to the naked eye False alarms due to lighting or flickering sunlight are minimised Compatible with Discovery and XP95 protocols XP95 Flameproof IR³ Flame Detector 201-0187 DIN-Rail Interface Enclosures DIN-Rail Interface Enclosures are available and can be used for housing intrinsically safe (IS) barriers or DIN-Rail mounted interfaces. A multi-purpose label that features a section for use with IS systems is supplied. For non-IS systems, the part referring to IS can simply be removed. XP95 IS DIN Rail Interface Enclosure (4 units) I.S. DIN Rail Interface (10 Units) 201-0142 201-0153 Intelligent Flameproof Dual IR Flame Detector The Intelligent Dual Infra-Red (IR²) Flame Detector is designed for use in areas where flaming fires may be expected. The detector has two sensors which respond to different IR wavelengths to discriminate between flames and spurious sources of radiation. Applications include aircraft hangars, coal handling and paper manufacturing plants and woodworking environments. •• •• •• •• •• •• •• Sensitive to flickering IR radiation Detects through films of oil, dust, water and ice Responds to flickering flames, including those invisible to the naked eye Compatible with Discovery and XP95 protocols Remote optical self-test function 90° field of view Up to 40m coverage XP95 Flameproof IR² Flame Detector www.ampac.net 201-0191 www.ampac.net 64 Detection Audio Visual & MCP’s & Interafaces 65 Marine Detection TM Orbis Marine Optical Smoke Detector The Orbis Marine Optical Smoke Detector works on the well established light scatter principle. However, the sensing technology is radically different in design from previous optical detectors and significantly reduces false alarms. Orbis Marine Optical Smoke Detector 201-0654 Orbis Marine Multisensor Detector The Orbis Marine Multisensor Detector benefits from the same false alarm reduction technology as the optical detector. It is a thermally enhanced smoke detector and so will not give an alarm from heat alone. Orbis Marine Multisensor Detector 201-0655 Orbis Marine Heat Detector The Orbis Marine Heat Detector uses a single thermistor to sense the air temperature around the detector. There are six classes of heat detectors in the Orbis Marine range designed to suit a wide variety of operating conditions. Orbis Marine A1R Heat Detector- Rate of Rise Orbis Marine A2S Heat Detector- Static Orbis Marine BR Heat Detector- Rate of Rise Orbis Marine BS Heat Detector- Static Orbis Marine CR Heat Detector- Rate of Rise Orbis Marine CS Heat Detector- Static 201-0162 201-0651 201-0650 201-0657 201-0652 201-0653 Orbis Marine TimeSaver Base The Orbis Marine TimeSaver Base is a completely new design that provides installers with an open working area with fixing holes shaped to allow a simple mounting procedure. Orbis Marine TimeSaver Base www.ampac.net 201-0656 www.ampac.net 66 Detection & MCP’s Xpander Wireless Detection 67 XPander Heat Detector and Mounting Base There are two heat detectors in the Xpander range designed to suit a wide variety of operating conditions. A static heat detector (CS) which responds only when a fixed temperature has been reached and a rate-of-rise detector (A1R) which has a fixed upper limit, but in addition, measures the rate of increase in temperature Voltage (regulated from radio base) Size inc base Operating temperature Relative humidity IP rating Weight inc base 3VDC 105mm D x 80mm H -10°C to +50°C (no icing) 0 to 95% (non condensing) IP23D 400 grams XPander A1R Heat Detector and Mounting Base XPander CS Heat Detector and Mounting Base 4106-5301 4106-5302 XPander Optical Smoke Detector and Mounting Base The Xpander Optical Smoke Detector works on the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely. Voltage3VDC Size inc base 100mm D x 75mm H Operating temperature -10°C to +50°C (no icing) Relative humidity 0 to 95% (non condensing) IP rating IP23D Weight inc base 500 grams XPander Optical Smoke Detector and Mounting Base 4106-5303 Xpander Combined Sounder & Detector The Xpander Combined Sounder and Detector is wireless and designed to proved one point notification and detection. Product Overview •• •• •• •• Traditionally, fire detection systems in industrial and commercial applications have used hard wired installations. These systems are generally installed at the time of construction or refurbishment, making the laying of cables not a great issue. However, certain applications do not lend themselves to this approach, such as occupied buildings, heritage sites, architecturally sensitive buildings and annexes. This is where wireless systems provide the ideal solution. Xpander is a system in which individual detectors, call points and alarm devices communicate with the XP95 loop by radio signals. •• •• •• •• •• •• •• •• Easy to install. XPERT card addressing. Self-monitoring. Proven technology. 915MHz radio channels. Up to 31 devices per interface. Up to 5 interfaces per loop (max devices per loop 126 inc interface) All detectors within the Xpander range are supplied complete with mounting bases. www.ampac.net Wireless Avaliable with a choice of Xpander detectors Bi-directional (monitored) radio platform A choice of 4 Tones including Temporal T3 XPander Sounder Heat A1R Combined Detector & Base XPander Sounder Heat CS Combined Detector & Base XPander Sounder Optical Combined Detector & Base 4111-1301 4111-1302 4111-1303 Xpander Combined Sounder Visual Indicator and Detector The Xpander Combined Sounder Visual Indicator and Detector is wireless and designed to privide a one point notification and detection. •• •• •• •• Wireless Avaliable with a choice of Xpander detectors Bi-directional (monitored) radio platform A choice of 4 tone including Temporal T3 XPander Sndr VI Red Heat A1R Combined Detector & Base XPander Sndr VI Red Heat CS Combined Detector & Base XPander Sndr VI Red Optical Combined Detector & Base XPander Sndr VI Clear Heat A1R Combined Detector & Base XPander Sndr VI Clear Heat CS Combined Detector & Base XPander Sndr VI Clear Optical Combined Detector & Base 4111-1401 4111-1402 4111-1403 4111-1501 4111-1502 4111-1503 www.ampac.net 68 Detection & MCP’s 69 Xpander Wireless Detection XPander Sounder Red and Red Mounting Base Xpander Hub & Cluster The Xpander Sounder and Sounder Base is wireless and designed to be used with Xpander detectors and manual call points. The Xpander Hub and Cluster System comprises of Radio Hub capable of receiving information from a maximum of 31 Radio Cluster Communicators (RCCs). The RCCs are each capable of receiving information from up to 31 wireless detection and alarm devices from the Xpander range. Voltage3VDC Alarm tones (selectable) includes Temporal T3 IP rating IP21C Sound output 100dB(A) XPander Sounder Red and Red Mounting Base XPander Sounder White and White Mounting Base 4107-8301 4107-8302 XPander Sounder Beacon The Xpander Sounder Beacon and Sounder Base is wireless and designed to be used with Xpander detectors and manual call points. Voltage3VDC Alarm tones (selectable) includes Temporal T3 IP rating IP21C Sound output 100dB(A) XPander Sounder Beacon Red and Red Mounting Base XPander Sounder Beacon Amber and White Mounting Base XPander Sounder Beacon Clear and White Mounting Base 4107-8303 4107-8304 4107-8305 Xpander Manual Call Point The Xpander Manual Call Point is compliant with AS7240-11 and is powered by two independent packs of three AA alkaline batteries with a typical five year life. Voltage Size inc base Operating temperature Relative humidity IP rating Weight inc base Regulated 3V from radio circuiting 105mm D x 80mm H -10°C to +50°C (no icing) 0 to 95% (non condensing) IP23D 500 grams XPander Manual Call Point Transparent Hinged Cover for Manual Call Point Operating Temperature Humidity Operating Voltage Power Requirements Radio Hub RCC Battery Backup: Radio Hub RCC Battery Standby Time: Radio Hub RCC Material: Dimensions and Weight of Interface 4105-5001 213-0064 www.ampac.net 4110-2001 N/A 1 x 6V 4Ah N/A 72 Hours ABS - IP54 270mm width x 205mm height x 85mm depth, 950 grams 4110-2004 4110-2005 Xpander Input/Output Unit The Xpander Input/Output Unit is a radio based interface and offers two monitored input circuts and two relay outputs. It can be used for controlling fire doors, fire dampers, smoke vents and other fire engineering applications. Supply Voltage Relay Rating Material Dimensions Operating Temperature Humidity IP rating 3VDC + 2A at 30VDC ABS grey plastic 120mm W x 240mmH x 60mm D -10°C to +55°C 0% to 95% relative humidity (no condensation) 65 XPander Input/Output Unit XPander Dual Input/Output Unit The Xpander Diversity Loop Interface Unit is connected to the detection loop and provides bi-directional communications from the LoopSense and FireFinder control panels to the wireless devices. XPander Diversity Interface Module with Isolator 40mA at 24V DC Mains Powered 220-240VAC, 50Hz Xpander Radio Hub Xpander Radio Communications Cluster Xpander Diversity Loop Interface Unit Voltage 24VDC + voltage pulses Operating Current 15mA Mechanical Isolation Isolator included as standard MaterialABS Dimension 270mmW x 205mmH x 85mmD Operating temperature -10°C to +55°C Humidity 0% to 95% relative humidity (no condensation) -10°C to 50°C (ambient) Up to 95% non-condensing 17 to 28V DC 4110-2002 4110-2003 Site Survey Kit The Xpander Survey Tool is used at the site survey stage to ascertain if a site is suitable for an Xpander installation. A site survey must be carried out before Xpander can be installed. •• •• Indicates the suitability of proposed device location. Tests for radio signal strength. XPander Site Survey Kit Power Supply for Site Survey Kit (4112-1001) 4112-1001 4112-1002 www.ampac.net 70 Detection & MCP’s Aspirating Smoke Detection -Wagner Titanus Family Product Overview TITANUS PRO•SENS® is a universal air sampling device suitable for a broad range of applications. The high degree of modularity of the device makes it possible to achieve a cost-effective solution – customised to suit the specific needs of the customer. An additional price advantage comes with the optional equipping of the device with a second detector module. The base TITANUS PRO•SENS® unit with 2 detector heads fitted (TITANUS PRO•SENS® 2) can be used for separate zone detection of a room and its equipment, or configured as a double knock tripping system. Each detector is completely separate, with no switching or leak between detection zones Robust & Efficient High Pressure Light Source (HPLS) Detection Technology •• •• •• •• •• •• •• •• •• •• •• •• LOGIC·SENS Fire Pattern Recognition Technology Freezer Version Operates in -40Deg to +60DegC with No Heater Boxes Required A Powerful & Efficient Aspirator Allowing up to 560m of Pipework A BlowFree System for Programmed or Automated On-Demand Pipe Clearing Modular Plug In Detector Heads for a Customised & Cost Effective Solution & Maintenance Dual Detector Ability Allows Separate Monitoring & Reporting of Room & Equipment with One Unit Time Saving Installation & Commissioning Via Plug & Play Setup Large Capacity 3-Stage Filters with Selectable 1-15 Micron Ratings A Large Range of Fittings, Pipework and Sampling Points XP95 Interfacing to FireFinderTM and LoopSenseTM Fire Control Panels FIP Bar Graph Display Module Available & SmartGraphicsHD Display Integration Cost Effective Solutions for Every Application Type www.ampac.net 71 Specifications Power Supply Detector Unit : PRO·SENS ®PRO·SENS® 2 Number of Sensor Modules Fitted : 1 2 Max. Number of Sampling Holes : 32 64 Max. Total Pipe Length Capable : 300m* 560m* Weight: 1460g1560g Current – Start Up Maximum: 300mA 320mA Current - Quiescent (at 24 VDC) 200mA 220mA Current - Alarm (at 24 VDC) 210mA 240mA Operating Voltage: 24 VDC (14 - 30 VDC) Tapered Pipe Connectors: 1 x 25mm 2 x 25mm Detector Dimensions (W x H x D) : 200 x 292 x 113mm Housing Colour: RAL 9018, Papyrus White Cabinet Type, Rating : ABS Plastics IP20 (Optional IP52) Temperature-Standard Version: -20 °C to + 60 °C Temperature-DeepFreeze Version: -40 °C to + 60 °C Humidity (Permanent) 10-95% Rel. Non-Condensing Cable Entries: 5 x M20, 2 x M25 Sensor Head Sensitivities: 0.5%, 0.1% and 0.015% Interface Types XP95 Addressable Loop, Conventional Circuit , Relays Alarms 4 Adjustable Threshold Levels: - Alert, PreAlarm, Alarm & Alarm2 Fault Signals Air Flow Low, Air Flow High, Processor/Hardware Fail, Ventilator Fail Air Stabilising Alarm & Fault Relay (CLI Version) 1A, 30 VDC max. Front Panel Control & Indications: Collective Fault - Yellow Operation – Green APID & CLI Versions: Reset & Isolate Controls Detector Isolation – Yellow X 2 Noise level Standard & Freezer - 45 dB(A), Silent Version - 23dB(A) Remote BarGraph Display: Panel Mounted Display Module *The maximum permissible length is pipe branch shape dependant. Item Numbers ProSens Base Unit-APID ProSens Base Unit-CLI ProSens Base Unit- OEM ProSens- 40 Base Unit- APID ProSens-40 Base Unit- CLI ProSens-40 Base Unit- OEM ProSens Detector 0.5% ProSens Detector 0.1% ProSens Detector 0.015% ProSens -40 Detector 0.5% ProSens -40 Detector 0.1% ProSens -40 Detector 0.015% Wagner Filter Box LF-AD Wagner Filter Element LF-AD-E Wagner Filter Box LF-AD-1 Wagner Filter Element LF-AD-ES Wagner Filter Box LF-AD-2 Wagner Filter Element LF-AD-E2 M *Wagner Filter Pipe SF-400 Short *Wagner Filter Element SF-400 *Wagner Filter Pipe SF-650 Long *Wagner Filter Element SF-650 Bar Graph Display - Titanus (panel kit) Bar Graph Display - Titanus (add on kit) Remote Bar Graph Display cw Enclosure *Allows full flow right up until 100% Capacity. Special order only. 7010-1000 7010-1010 7010-1020 7010-1100 7010-1110 7010-1120 AD-10-5130 AD-10-5100 AD-10-5115 AD-10-5200 AD-10-5190 AD-10-5195 AD-10-1960 AD-10-0330 AD-10-1963 AD-10-0335 AD-10-1966 AD-10-0332 AD-10-2010 AD-10-1930 AD-10-2000 AD-10-1920 159-0280 4310-0088 4310-0089 www.ampac.net 72 Detection & MCP’s 73 High Sensitivity Detection System Aspirating Smoke Detection - FastSense Product Overview FastSense is an aspirating system that adopts laser technology making it extremely sensitive, thus providing the earliest warning to the slightest traces of smoke. FastSense is available in 3 models: FastSense 25, FastSense 100, FastSense PLUS. The FastSense 25 accommodates sampling pipe up to 25 metres in length while the FastSense 100 and FastSense PLUS has total sampling pipe capacity of 100 metres and 200 metres respectively. •• •• •• •• •• •• Advanced Laser Technology ClassiFire Artificial Intelligence software Patented ‘Wastegate’ system In-built bar-graph and smoke level display; and programming (Available only with the FastSense PLUS) Apollo Protocol Interface Card Interface (APIC) provides portal for indication and control of FastSense detectors at Ampac’s FireFinder Fire Alarm Control Panel FASTSENSE Models Voltage Quiescent current Dimensions (mm) Height Width Depth High Sensitivity Detection System The HIgh Sensitivity detectors are complemented by a range of light grey fittings intended to ensure that the system will suit most applications. •• •• •• •• •• •• Pipes, printed with red markings, have ‘bell’ ends for easy fit to the next pipe, thus saving time and material (less need for coupling for pipe joins). T-piece is available with friction or lock fitting. The friction fit sampling points are aesthetically designed and have an easy fit ‘finger twist’ lock nut. Resilient snap-on conduit saddle clips and collars, are a boon for installers. Sampling kits are available with either friction or locking TPiece and also includes a one (1) metre sampling tube and sampling point Sampling pipe plug available for extending sampling point whilst being unobtrusive. Item Numbers Pipe (4M Length) Pipe Coupling Std DX 40025 Pipe Coupling IP65 DX 43025 FitAncilliaries Large 90o Bend - Standard End Cap 25mm DX52125 Pipe Clip Saddle GW50603 Pipe Clip Mounting Rail GW50609 Label Sampling Pipe Roll Sampling Point Kit 10mm - Friction Fit Sampling Point Kit 10mm - Locking Tube - 10mm (100 metre roll) natural Wagner Reducer Film 2.0mmGrey Standard-Grey Wagner Reducer Marking Tape www.ampac.net 230-0061 230-0062 230-0063 230-0067 230-0068 230-0072 230-0074 230-0121 230-0081 230-0082 230-0112 01-10-9390 01-10-9330 Relay Outputs (All normally open 1 Amp) Fire 1 Fire 2 Pre-Alarm Auxiliary Fault 25 27 VDC 250mA 100 27 VDC 400mA PLUS 27 VDC 400mA 215 220 372 140300427 859095 Optional Optional Optional Optional OptionalOptional OptionalOptional OptionalOptional Fitted Fitted Fitted Fitted Fitted No. of Pipe Inlets 1 2 4 Max. Pipe Length 25m 100m 200m Sensitivity Range Minimum 25%25%25% Maximum 0.03%0.03%0.03% Data Bus 1.2km1.2km1.2km IP Rating IP50IP50IP50 Operating temperature -10°C to +60°C Humidity0 to 90% non-condensing Weight 1.7kg3.8kg5.2kg ApprovalsAS1603.8 Item Numbers FastSense 25 detector & docking station FastSense 100 detector & docking station FastSense PLUS detector FastSense PLUS detector + command module FastSense Range Apollo XP95 Interface (APIC) FastSense 25/100 Dust Filter FastSense Plus Dust Filter 230-0001 230-0002 230-0011 230-0012 230-0041 230-0147 230-0148 www.ampac.net 74 Audio Visual & Interafaces 75 Ampac Interfaces Single Input/Output Device The Ampac Single Input Output Device is designed to interface to a variety of plant control equipment such as door contacts, sprinkler flow switches and fire fan control systems. •• •• •• •• •• •• •• •• •• Loop Powered Monitored Input Change Over Relay Output Compatible with XP95 & Discovery Protocol Built In Short Circuit Isolator Low Power Consumption Diagnostic LED Indications Surface Mount Enclosure DIN Rail Mount Option Single Input Output Device DIN Mount Single Input Output Device Enclosed Single Input Device DIN Mount Single Input Device Enclosed 4210-0050 4210-0051 4210-0052 4210-0053 Three Input Output Device The Ampac Three Input Output Device is designed to interface to a variety of plant control equipment such as door contacts, sprinkler flow switches, gas valves and fire fan control systems. •• •• •• •• •• •• •• 3 x Independent Monitored Inputs 3 x Change Over Relay Outputs Loop Powered inc Short Circuit Isolator Compatible with XP95 & Discovery Protocol Low Power Consumption Diagnostic LED Indications Surface and DIN Mount Enclosures Product Overview Three Input Output Device DIN Mount Three Input Output Device Enclosed Three Input Device DIN Mount Three Input Device Enclosed Ampac offer an extensive range of addressable Interface devices which have a new uniform sleek design for ease of installation and commissioning. Designed for the monitoring and controlling of many types of essential plant equipment, the Interface devices enable fire protection solutions to be engineered simply and effectively without the need for specialist enclosures. 4210-0054 4210-0055 4210-0056 4210-0057 The range includes both single and 3 channel input output devices together with a zone input device that may be mounted in bespoke enclosures, direct surface wall mounted or DIN rail mounted. Input / Output Input Zone Input Operating voltage 3 Input / Output 3 Input 17 to 28 V dc Quiescent current at 24 V dc 1.25mA 1.25mA 7.5mA 1.31mA 1.25mA Max loop current at 24 V dc 2mA 1.51mA 3.6mA 1.59mA 1.54mA 1A at 30V ac/dc N/A 1A at 30V dc 1A at 30V ac/dc N/A Output rating Operating temp Relative humidity -20°C to +70°C (no icing) 0 to 95% (non condensing) Dimensions - DIN 110W x 75H x 25D mm 144W x 75H x 25D mm Dimensions - Enclosed 150W x 200H x 52D mm 150W x 200H x 52D mm IP Rating www.ampac.net IP44 Zone Input Device The Zone Input Device is designed to allow up to 40 conventional detectors to be interfaced to the Ampac range of Apollo analogue addressable control panels. •• •• •• •• •• •• •• •• •• Conventional Monitored Input Selectable EOL Monitoring Device Loop Powered Compatible with XP95 & Discovery Protocol Built In Short Circuit Isolator Low Power Consumption Diagnostic LED Indications Surface Mount Enclosure DIN Rail Mount Option Zone Input Device DIN Mount Zone Input Device Enclosed 4210-0058 4210-0059 www.ampac.net 76 Audio Visual & Interafaces 77 XP95 Interfaces Input/Output Unit with Isolator The Input/Output unit with Isolator provides a voltage free, single, pole, change-over relay output, a single, monitored switch input and an unmonitored, non-polarised opto-coupled input. •• •• •• •• •• •• It can report fault, switch open and switch closed levels Three visible LEDs Loop powered Voltage free Capable of switching up to 1A at 30V Built-in short circuit isolator Input Unit with Isolator Output Unit with Isolator 201-0151 201-0152 Zone Monitor with Isolator The Zone Monitor with Isolator powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 Loop. •• •• •• Loop powered Visible LED Built-in short circuit isolator Discovery/XP95 Zone Monitor with Isolator 201-0126 Product Overview There are a variety of XP95 interfaces available to suit a number of individual applications. Standard interfaces are fitted with bi-directional short circuit isolators so that they are unaffected by a single short circuit on either loop input or output. The exception to this is the Main Input/Output Unit which is not isolated. DIN-Rail interfaces feature enclosures that clip to standard 35mm DIN rails or are screwed to the base of a larger enclosure. They enable fire system designers to create multi-purpose interfaces for individual sites. Input / Output Zone Monitor Sounder Unit Operating voltage Switch Monitor (inc Plus) Mains Input / Output 3 Input / Output Mini Switch Monitor Sounder Control Unit with Isolator The XP95 Sounder Control Unit with Isolator is used to control the operation of a zone of conventional sounders and report their status to the control panel. •• •• Allows sounders to be operated continuously or be pulsed or be pulsed, 1 second on 1 second off May be synchronized when in pulsed operation Sounder Control Unit with Isolator 17 to 28 V dc Quiescent current at 24 V dc 1.25mA 4mA + detectors 1.95mA 1.25mA 1.25mA 3mA 200 μA Max loop current at 24 V dc 3.5mA 11mA 3.6mA 4.2mA 3.5mA 7.5mA 3.4mA Output rating 1A at 30V dc N/A 1A at 30V dc 1mA (opto) 5A at 250V ac 1A at 30V dc Operating temp -20°C to +70°C (no icing) Relative humidity 0 to 95% (non condensing) N/A Three Channel Input/Output Unit with Isolator The Three Channel Input/Output unit with Isolator provides three voltage free, single pole, change-over relay outputs, and three monitored switch inputs. Dimensions 150W x 90H x 48D mm - - Weight 240 grams 621 grams 30 grams IP Rating IP54 IP54 - •• •• •• •• Supervises one or more normally-open switches on each of the three inputs Loop powered Capable of switching up to 30V at 1A on each of the three outputs Built-in short circuit isolator Three Channel Input/Output Unit with Isolator www.ampac.net 201-0127 201-0175 www.ampac.net 78 Audio Visual & Interafaces 79 XP95 Interfaces Alarm Acknowledgement Facility Mains Switching Input/Output Unit The XP95 Loop Powered Mains Switching Input/ Output Unit provides a voltage free, single pole charge- over relay output and a monitored switch input. •• •• •• Supervises one or more normally-open switches connected to a single pair of cables Three visible LEDs Capable of switching 250 vac at up to 5 amps Mains Switching Input/Output Unit 201-0180 Mini Switch Monitor with Isolator The Mini Switch Monitor is an interface within an entirely new housing. This allows the unit to be fitted onto a standard 35mm DIN-Rail (using a twist-click motion) or mounted within an enclosure, for example a Manual Call Point. It is designed to monitor the state of one or more single pole, volt-free contacts connected on a single pair of cables and to report the status to the FireFinder or LoopSense addressable control equipment. •• •• •• •• •• The Alarm Acknowledgment Facility (AAF) is a loop powered addressable device that helps reduce the costly consequence of an unwanted alarm. Operating Voltage Quiescent Current Additional Operational Currents Temperature Humidity (Non Condensing) Address Setting Alarm Current Dimension Weight Compliance 21 to 28 VDC (loop powered) 900µAA at 24VDC Ext “Hush” enabled +100µA Poll LED “ON” steady +2mA Alarm LED “ON” steady & buzzer sounding– Ia = <8mA -20°C to 70°C 0 to 95% 1 to 126 <8mA at 24VDC Single gang Clipsal plate 45 grams AS7240.2 and AS4428.1 amendment 1 Alarm Acknowledgement Facility AS7240 Alarm Acknowledgement Facility Horizontal AS7240 226-0002 226-0004 Designed for use where space is limited Built in short circuit isolator Interrupt/non interrupt in one unit ‘Pre-alarm’ status available Three coloured LEDs giving clear status indication XP95 Mini Switch Monitor with Isolator 201-0184 Apartment Module The Apartment Module (AM) is a loop powered addressable device that helps reduce the costly consequences of an unwanted alarm Operating Voltage Quiescent Current Alarm Current Zone Circuit Zone EOL Speaker Circuit Address Setting Dimension Material Weight Apartment Module www.ampac.net 21 to 28 VDC (loop powered) 4.9mA with 6k2Ω EOL 1.9mA with 10μF EOL 4.2mA + Zone alarm current of 14.5mA 10 detectors (max) with 6k2Ω EOL (detector current < 1.2mA) 20 detectors (max) with 10μF EOL (detector current < 2.4mA) 6k2Ω, 10μF 100Volt line, 6 W max, 47k EOL 1 to 126 Single gang PDL plate High impact ABS (white) 45 grams 226-0003 www.ampac.net 80 Audio Visual & Interafaces 81 Conventional Audio Visual Vantage Sounder Vantage LED Beacons The Vantage spatial sounder has been designed for general purpose, fire and security applications and incorporates AS1670.4 compliant signal tones. Designed as a general purpose LED beacon for fire, security and industrial applications, the Vantage Beacon incorporates the latest in energy efficient LED technology to provide maximum all-round visibility in an aesthetically pleasing body with minimum power requirements. Operating voltage Volume setting Current @ 24VDC Sound output @ 1m (Tone 1) Number of tones IP Rating (shallow) IP Rating (deep) Operating temperature Humidity Dimensions (mm) Weight Approvals 21 - 28VDC Low Med High 9mA 18mA 36mA 86dBA 101dBA 106dBA 32 IP43 IP65 -20°C to +70°C (no icing) 0 to 95% (non condensing) 94Ø x 85H(shallow), 94Ø x 102H (deep) 200g (shallow), 220g (deep) EN54-3, AI 2002, A2 2006 Vantage Sounder Red with Shallow Base Vantage Sounder White with Shallow Base Deep Base Only Red Deep Base Only White 205-0062 205-0063 205-0064 205-0065 Operating Voltage Supply Current Flash Rate Operating Temp. Humidity Material Dimensions Shallow Base Deep Base IP rating Weight 20 - 35V DC 9mA T3 Temporal (red & clear) 1Hz (amber) -20°C +70°C 0 to 95% Non-condensing ABS fire retardant plastic 94mm Ø x 60mm H 94mm Ø x 77mm H IP43 (shallow), IP65 (deep) 145g (shallow), 165g (deep) Red LED Beacon White Shallow Body Amber LED Beacon White Shallow Body Red LED Beacon White Deep Body Amber LED Beacon White Deep Body Red LED Beacon Red Deep Body Amber LED Beacon Red Deep Body Clear Lens Red LED Beacon White Shallow Body 4107-1001 4107-1002 4107-1003 4107-1004 4107-1009 4107-1010 4107-1011 Vantage Combi The Vantage Combi is a combined low profile electronic reflex horn sounder incorporating a high output LED cluster strobe array. The Vantage Combi has been designed for general purpose, fire and security applications and incorporates AS1670.4 compliant signals. Voltage 18 to 35 VDC Volume setting Low, Med & High Current (mA @ 27VDC ) 11 - 48mA Sound Output (dB @ 1m) 85 - 100dB SignalAS1670.4 Flash rate 1 per sec Size (shallow) 93mm Dia x 90mm H Size (deep) 93mm Dia x 107mm H Temperature range -20°C to +70°C Humidity 0 to 95% IP Rating (shallow base) IP43 IP Rating (deep base) IP65 Weight 223g & 253 ApprovalsAS1670.4 Deep Base Only Red Deep Base Only White Vantage Combi Red with Shallow Base Vantage Combi White with Shallow Base Amber Sounder Beacon White Deep Body (VTB-32 Tone) www.ampac.net Vector Sounder The Vector sounder has been designed for general purpose conventional fire detection applications and incorporates AS1670.4 compliant signal tones. The Vector sounder can be installed as a sounder base for Ampac conventional detectors or a surface mount sounder when used in conjunction with the optional lid Operating voltage 8 to 35 VDC Supply current Evac 15mA @ 24VDC Supply current Alert 8 mA @ 24VDC Signal output AS1670.4 Max. Output level 91 dBA @ 1 metre with detector Evac 93 dBA @ 1 metre with lid Volume control -30dBA IP rating IP42 Temperature range -20 to + 70°C ConstructionABS Dimension (mm) 106Ø x 35h (Sounder & lid only) 205-0064 205-0065 205-0066 205-0067 4107-5001 Vector Sounder Vector Sounder Lid 205-0077 205-0017 www.ampac.net 82 Audio Visual & Interafaces 83 Conventional Audio Visual Remote Indicators Vantage Dual LED Beacon Fire Alarm Remote Indicator - Round The Vantage Dual LED Beacons are designed for use with the EV3000 Emergency Warning and Intercommunication Systems. Incorporating the latest in LED technology, the Vantage beacon offers maximum all-round visibility in an aesthetically pleasing body with minimum power requirements. The low current features of the product allow installers to use a larger number of visual devices on the EV3000 which negates the need for additional output circuits and power supplies. Ampac offer a range of remote indicators which are designed for fire detection systems requiring local indication of an individual or group of detection devices located in concealed areas. Applications include floor and ceiling voids spaces, roof spaces, lift shafts and escalator machine rooms. Operating Voltage Supply Current Flash Rate Operating Temp. Humidity Material Dimensions Flush Surface IP rating Weight 18 - 35V DC 9mA T3 Temporal (red), 1Hz (amber) -20°C +70°C 0 to 95% Non-condensing ABS fire retardant plastic Voltage Current at 24v Size Weight Remote Indicator – Fire Alarm in Concealed Space Remote Indicator – Fire Alarm in Roof Space Remote Indicator – Fire Alarm in Room Remote Indicator – Fire Alarm in Duct Remote Indicator – Fire Alarm in Cupboard Remote Indicator – Fire Alarm Under Floor Remote Indicator – Fire Alarm in Return Air Remote Indicator – Fire Alarm in Exhaust Duct Remote Indicator – Fire Alarm in Supply Air Duct Remote Indicator – Fire Alarm in Ceiling Remote Indicator – Fire Alarm Above Remote Indicator – Fire Alarm Remote Indicator – Detector Activated 188mm L x 94mm W x 62mm H 188mm L x 94mm W x 80mm H IP43 (shallow), P65 (deep) 215g (shallow), 235g (deep) Dual LED Beacon Shallow Base Dual LED Beacon Deep Base 24 VDC 1.5mA 74mm Dia x 16mm H 26 grams 4107-1005 4107-1006 209-0004 209-0005 209-0006 209-0007 209-0008 209-0009 209-0010 209-0011 209-0012 209-0013 209-0014 209-0020 209-0023 Beacon / Strobe Sign Plate The beacon / strobe sign plate mounts directly behind the single Beacon or Sounder/ Beacon and is generally located outside the main entrance to the building to attract the attention of approaching fire fighters. Indicator / Buzzer & Indicator / Buzzer with Mute Fixing Strobe / Beacons Material Size •• •• •• •• Directly behind the Sonos Model Painted metal 1mm 120mm W X 160mm H Vantage Sounder / Beacon FIRE Legend Plate ASL-86 Strobe FIRE Legend Plate 4210-0048 4210-0049 Xenon Strobes AMPAC offer the flexibility of individual red and amber strobes or a combined red/ amber strobe unit, complete with mounting box and terminals. Voltage 24 VDC Current140mA Rating 10 Watts Size inc base 100Dia x 88H mm Flash rate 75 per minute Operating temperature -20°C to + 60°C IP rating IP65 Weight – strobe 182 grams Weight – combined unit 719 grams 24V Strobe Light Red ASL86 24V Strobe light Amber ASL86 24V Strobe Light Combined Red/Amber www.ampac.net Alarm activation indicator and buzzer 10mm red flashing LED Buzzer (with mute facility) Modern styling Indicator / Buzzer Voltage 24 VDC Current at 24v 27mA LED flash rate 45 per minute Buzzer 3.8kHz @ 114dBA Size 70H x 110W x 10D mm Weight64g Indicator / Buzzer with Mute Voltage 24 VDC Current at 24v 43mA LED flash rate 45 per minute Buzzer 3.8kHz @ 114dBA Size 70H x 110W x 10D mm Weight89g Flashing Indicator / Buzzer Flashing Indicator / Buzzer with Mute Switch 209-0017 209-0016 208-0007 208-0008 208-0011 www.ampac.net 84 Audio Visual & Interafaces 85 Bells Warning Signs Fire Alarm Bell 150mm The Fire Alarm Bell is a motorised, maintenance free bell designed for fire alarm applications. Its low current consumption, ease of installation incorporating diode polarity suppression and universal recognisable bell sound, makes it an ideal choice for fire alarm installations. Voltage Operating current Size (without back box) Sound level Operating temperature Weight 12V DC or 24V DC 55mA or 25mA 150mm Dia x 56mm D 92 dB @ 1m -10°C to +55°C (no icing) 764 grams AFB-63 Bell 150mm Red 24VDC AFB-63 Bell 150mm Red 12VDC 206-0012 206-0011 Fire Alarm Bell 200mm The Fire Alarm Bell incorporates a solenoid actuation mechanism and is designed for fire alarm applications. Its low current consumption, ease of installation incorporating diode polarity suppression and traditionally recognisable bell sound, makes it an ideal choice for fire alarm installations. Voltage 19-27 VDC Operating current 100mA Size (without back box) 200mm Dia x 70mm D Sound Level 85 dB @ 3m Operating temperature -20°C to +70°C (no icing) Weight1.25kg Bell 200mm 24v dc Red 206-0011 Product Overview The Ampac range of Warning Signs offer state of the art LED technology for a variety of applications in a highly aesthetic design. The slimline enclosure can easily be adapted to surface or semi-flush mounting while a range of standard fascia plates has been developed to suite Agent Release applications. A weatherproof version is also available along with custom legend fascia plates. A maximum of 6 Warning Signs can be connected to the output of each Agent Release module located within the ZoneSense, FireFinder or LoopSense fire control panels. •• •• •• •• •• •• •• •• •• •• •• Low Power Consumption High Efficiency LED Indications Aesthetically Pleasing Two or Three Wire Connectivity Single or Dual Level Operation Continuous or Flashing LED Operation Synchronisation between Signs Integral Buzzer with Mute Facility External Sounder Output Surface or Semi-Flush Fixing Waterproof Version 4210-0110 4210-0120 Operating Voltage Power Consumption Surface mounting of bell box designed for use with the 150mm and 200mm Bell. Humidity IP rating Dimension (mm) Level 1 & 2 active – 100mA at 24 Vdc -20°C to +55°C 0% to 95% non condensing 4210-0110 – IP30 Material Material Cast Aluminium FinishRed Depth 40 mm Weight 270 grams www.ampac.net Level 1 active – 50mA at 24 Vdc Operating Temperature Bell Back Box Bell Back Box 17 Vdc to 29 Vdc 4210-0120 – IP65 ABS Enclosure / Acrylic Fascia 4210-0110 – 195H x 325W x 50D 4210-0120 – 212H x 338W x 67D Item Numbers 206-0006 Warning Sign (no fascia plate) Warning Sign IP65 (no fascia plate) ‘Fire Alarm - Do Not Enter’ (fascia plate only) ‘Fire Alarm - Evacuate Area’ (fascia plate only) ‘Do Not Enter - Gas Discharged’ (fascia plate only) ‘Fire Door Closing’ (fascia plate only) ‘Extinguishing System Inoperative’ (fascia plate only) Custom Legend (specify text) Wall / Ceiling Mount Surround - Smart Term/Warning Sign Dual Ceiling Mount Surround for Warning Sign 4210-0110 4210-0120 4210-0131 4210-0132 4210-0133 4210-0134 4210-0135 4210-0136 4210-0046 4210-0047 www.ampac.net 86 Audio Visual & Interafaces 87 Speakers One-Shot Ceiling Speaker Surface Speaker - 100mm The 100mm and 200mm One Shot ceiling speakers are ideal for use in a wide range of applications including Emergency Warning Systems (EWS), Background Music and Public Address (PA) paging within shopping centres, offices and hotels. The One Shot speaker units install in seconds. They simply snap fit to any 10-13mm thickness ceiling by means of the 3 integral pressure clips. The Surface Mount 100mm Speaker is an excellent choice for use in plant rooms, warehouses, shopping centres and malls. The custom designed speaker and transformer assembly has been engineered to meet Australian Fire Evacuation Standards Rated Power Line Voltage Frequency R esponse SPL Speaker Tap (watt) Cut-out size Dimensions Weight Driver Power taps SPL 1W @ 1m Frequency response Connection 5 watts 100 Volt 100 Hz to 15 kHz 98 dB (1 watt @ 0.5m) 0.33, 0.66, 1.25, 2.5, 5 140 mm Diameter 155 x 110 Hmm 850 grams Ceiling Speaker – 100mm One-Shot (White) Ceiling Speaker – 100mm One-Shot (Black) Ceiling Speaker – 200mm One-Shot (White) One Shot Combo Speakers (Box Qty 32) One Shot Combo Grills (Box Qty 32) Surface Speaker – 100mm 218-0026 218-0031 218-0032 4113-1001 4113-1002 The EasyFit range of Ceiling Speakers are lightweight, quick and easy to install, and are finished in unobtrusive white with an attractive metal grille. The EasyFit Ceiling Speaker offers a wide frequency range along with good sound dispersion ensuring quality music reproduction and excellent speech intelligibility. The 100mm speaker is ideal for use in a wide range of applications including Emergency Warning Systems (EWS), Background Music and Public Address (PA) paging within shopping centres, offices and hotels. 5 watts 100 Volt 100 Hz to 20 kHz 96 dB (1 watt @ 0.5m) 0.33, 0.66, 1.25, 2.5, 5 85 mm Diameter 100 x 105 Hmm 800 grams Driver Maximum/rated power Power taps Frequency Range Axial sensitivity 1W/1m/1kHz Opening Angle( -6dB) Ceiling Speaker – 100mm Recessed Low Profile Grill 218-0008 218-0003 The 200mm speaker is ideal for use in a wide range of applications including Emergency Warning Systems (EWS), Background Music and Public Address (PA) paging within shopping centres, offices and hotels. Rated Power Line Voltage Frequency R esponse SPL Speaker Tap (watt) Cut-out size Dimensions Weight Ceiling Speaker – 200mm Recessed Low Profile Grill www.ampac.net Ceiling cutout diameter Overall dimensions Safety Ceiling Speaker - 200mm Recessed 5 watts 100 Volt 100 Hz to 20 kHz 96 dB (1 watt @ 0.5m) 0.33, 0.66, 1.25, 2.5, 5 190 mm Diameter 200 x 75 Hmm 1 kg 218-0022 EasyFit Ceiling Speakers Ceiling Speaker – 100mm Recessed Rated Power Line Voltage Frequency R esponse SPL Speaker Tap (watt) Cut-out size Dimensions Weight 100mm (4”) dual cone 0.33, 0.66, 1.25, 2.5, 5W 90dB @ 1kHz (+/- 2dB) 100Hz-15kHz 4 way terminal block + 22uF bipolar capacitor 4 Inch 5 Watt 6 Inch 10 Watt 8 Inch 15 Watt 8 Inch 30 Watt 4” 6.5” 8” 8” 8W/5W 15W/10W 22W/15W 45W/30W 5, 2.5, 1.25, 0.66, 0.33W 10, 5, 2.5, 1.25W 15, 10, 5, 2.5, 1.25W 30, 15, 7.5, 3.75W 100Hz - 15kHz 60Hz - 20kHz 50Hz - 17kHz 50Hz - 17kHz 94dB SPL 91dB SPL 93dB SP 93dB SPL 144° / 93° at 1kHz / 4kHz 170° at 1kHz 165° at 1kHz 100° at 1kHz 140mm 195mm 238mm 238mm 170mm x 110mm 220mm x 115mm 273mm x 103mm 273mm x 115mm acc to EN 60065 acc to EN 60065 acc to EN 60065 acc to EN 6006 Ceiling Speaker, Easyfit 5w 4” - EVAC Ceiling Speaker, Easyfit 5w 5” - Brilliant White Ceiling Speaker, Easyfit 5w 5” White Ceiling Speaker, Easyfit 10w 6.5” Ceiling Speaker, Easyfit 15w 8” White Ceiling Speaker, Easyfit 30w 8” White 218-0041 218-0042 218-0043 218-0044 218-0045 218-0046 218-0009 218-0021 www.ampac.net 88 Audio Visual & Interafaces 89 Addressable Audio & Visual Speakers Horn Speaker - 10 Watt Integrated Sounder Base The Ampac 10 Watt/ 20 Watt Horn Speaker is specifically designed for distributed Public Address (PA) and Emergency Warning Systems (EWS) with frequency response characteristics ensuring clear speech reproduction during announcements. The Integrated Sounder Base comprises a base sounder with integral mounting base and is for use with Discovery or XP95 ranges. It is designed for indoor use. Rated Power Line Voltage Frequency R esponse SPL Speaker Tap (watt) Dispersion angle Material IP Rating Dimensions Weight Horn Speaker – 10 Watt Horn Speaker – 20 Watt Horn Speaker Bracket Wurli-Gig 10 watts 100 Volt 250 Hz to 13 kHz 105 dB (1 watt @ 1m) 1.25, 2.5, 5, 7.5, 10 110° UV stabilised plastic IP65 150 Dia x 190 Dmm 1.4 kg www.ampac.net 201-0110 201-0114 218-0028 218-0007 218-0040 Addressable Beacon Base The High Efficiency Ampac 10 and 20 watt horn loudspeaker is specifically designed for distributed Public Address (PA) and Emergency Warning Systems (EWS) with frequency response characteristics ensuring clear speech reproduction during announcements. Horn Speaker Bosch Easy Fit 10W IP66 Grey Horn Speaker Bosch Easy Fit 20W IP66 Grey 17-28 VDC 1.2mA 5mA 92dB(A) -20°C to +60°C (no icing) 0 to 95% (non condensing) IP21D 115Dia x 38H mm 140 grams Integrated Base Sounder White Cap Horn Speaker - 10 Watt / 20 Watt Rated input Power handling Power taps SPL at Rated Power (10W @ 1m) SPL at Rated Power (1W @ 1m) Frequency Range (-10dB) Dispersion Angle(-6dB) Weight Voltage (polarity sensitive) Quiescent current Max current (sounder operated) Max sounder output Operating temperature Relative humidity IP rating Size Weight 10 Watt 20 Watt 100V100V 10W20W 10, 7.5, 5, 2.5, 20, 15. 10, 1.257.5, 5W 119 dB 124 dB 108 dB 110 dB 300Hz - 13kHz 9kHz 140°@1kHz 90°@1kHz 1.3KG 2.1KG 218-0047 218-0048 The Beacon Base is a loop-powered beacon combined with a standard Intelligent Mounting Base. It is used to signal a fire alarm in enclosed areas. The Beacon Base can be used either with a detector fitted or with a cap for operation as a stand-alone alarm device. Voltage (polarity sensitive) Quiescent current Max current (sounder operated) Max sounder output Operating temperature Relative humidity IP rating Size Weight Beacon Base White Cap 17-28 VDC 300μA at 24V DC 3.1mA at 24V DC 92dB(A) -20°C to +60°C (no icing) 0 to 95% (non condensing) IP21D 115mm Dia x 31mmH 109 grams 201-0120 201-0114 www.ampac.net 90 Audio Visual & Interafaces 91 Addressable Audio & Visual Sounder Beacon Base Intelligent Open-Area Beacon The Sounder Beacon Base is a loop-powered sounder and beacon combined with a standard Intelligent Mounting Base. It is used to signal a fire alarm in enclosed areas. The Sounder Beacon Base can be used either with a detector fitted or with a cap for operation as a stand-alone alarm device. The Intelligent Open-Area Beacon has been developed for use in situations where there is a risk that sounders will not be heard. It is weatherproof and can be used outside. Voltage (polarity sensitive) Quiescent current + Beacon Max current (sounder operated) Max current (beacon only) Max sounder output Operating temperature Relative humidity IP rating Size Weight 17-28 VDC 300µA 8mA 3.1 mA 91dB(A) -20°C to +60°C (no icing) 0 to 95% (non condensing) IP21D 115Dia x 38H mm 160 grams Sounder Beacon Base Beacon Base White Cap 17-28 VDC 333µA 3.1mA 1Hz -10°C to +55°C (no icing) 0 to 95% (non condensing) IP65 104Dia x 97.5H mm 205 grams Intelligent Open Area Beacon (Red) Sonos Intelligent Open Area Beacon (Clear) Sonos 208-0100 208-0101 201-0116 201-0120 201-0114 Loop-Powered Beacon Intelligent Open-Area Sounder / Sounder Beacon The Loop-Powered Beacon is a local-area beacon designed for indoor use. The beacon has been developed as a supplement to sounders for use in situations where there is a risk that sounders will not be heard. The Intelligent Open-Area Sounder /Sounder Beacon has been designed for use in open areas and can be connected to any Discovery or XP95 system. Voltage (polarity sensitive) Quiescent current Max current (beacon operated) Flash rate Operating temperature Relative humidity IP rating Size Weight 17-28 VDC 150µA 3mA 1Hz -20°C to +60°C (no icing) 0 to 95% (non condensing) IP23D 115Dia x 38H mm 140 grams Loop-Powered Beacon (Red) Loop-Powered Beacon (Amber) Standard Flash Loop-Powered Beacon (Clear Lens/Red Flash) Standard Flash www.ampac.net Voltage (polarity sensitive) Quiescent current Max current (beacon operated) Flash rate Operating temperature Relative humidity IP rating Size Weight 201-0118 201-0156 201-0157 SounderSounder/Beacon Voltage (polarity sensitive) 17-28 VDC Quiescent current 333µA Max current 5mA8mA (sounder/beacon operated) Max sounder output - 1Hz Operating temperature -10°C to +55°C (no icing) Relative humidity 0 to 95% (non condensing) IP rating IP65 Size 104Dia x 97.5H mm Weight 225 grams 260 grams Intelligent Open Area Sounder (Red) Sonos Intelligent Open Area Sounder (White) Sonos ntelligent Open Area Sounder Beacon (Red) Sonos Intelligent Open Area Sounder Beacon (Clear) Sonos 205-0100 205-0101 I 205-0102 205-0103 www.ampac.net 92 Audio Visual & Interafaces 93 Hazardous Area - Intrinsically Safe Hazardous Area- Flameproof Equipment Product Overview The Intrinsically Safe range of products includes the compact I.S. Sounder, I.S. Beacon and I.S. Sounder / Beacon. The range is suitable for all intrinsically safe signalling applications including fire, security and process control. Approvals include ATEX and IECEx and GOST-R for Zone 0 applications and FM approval for Class I Division 1 and Class I Zone 0 applications. The I.S. Beacon optimises the effectiveness of its six high output LEDs via a prismatic lens design. The I.S. combined Sounder and Beacon requires only one Zener barrier or galvanic isolator to run both sounder and beacon or alternatively the unit can be operated as individual signals. Power to the I.S. range should be via a certified zener barrier or galvanic isolator whose output parameter is no greater than, Uo=28v dc, Io=93mA,and Po=660mw. The beacon is internally input overload and reverse polarity protected and is end of line monitoring resistor certified. •• •• •• •• •• Input Overload and Reverse Current Protection End of Line Resistor Certified ATEX and IECEx approval 2 x M20 clearance gland knockouts Auto Synchronised Sound Output (exc. Beacon) Voltage Range 25mA at 24V DC - Flash Rate - Number of Tones Temperature range Beacon Sounder/Beacon 16-28Vdc via Zener barrier or galvanic isolator Energy Sound Output (nominal) at 1m +/- 3dB – Tone 2 The flameproof range of products is ideal for hazardous areas, specifically Zone 1 and 2 applications. The use of flameproof technology ensures that engineers installing into hazardous areas need not fit an intrinsically safe barrier and the associated wiring requirements. Sound level outputs are up to 117dB(A) at 1 metre with a choice of 32 alarm tones and 3 remotely selectable stages. Housings are manufactured from corrosion proof, marine grade copper free LM6 aluminium which is phosphated and powder coated. All models have two M20 cable entries, large termination areas and an ingress protection of IP66/67. Two entry points for cabling are present for IN and OUT wiring, thus eliminating the requirement for additional flameproof junction boxes. Sounder Nominal Current Consumption Product Overview 25mA at 24V DC 30mA at 24V DC double flash at 2Hz and 1Hz 23cd 23cd 100dB(A) 100dB(A) 49 49 •• •• •• •• •• •• •• ATEX and IECEx approval Rapid installation with no barrier requirements Suitable for Zone 1 & 2 flameproof applications Large termination area Ratchet adjustable stainless steel ‘U’ bracket Synchronisation on multi-sounder systems Sounders have 32 synchronised tones available Voltage Range Nominal Current Consumption -40 to +60°C Beacon Sounder Sounder/Beacon 20-28V DC 20-28V DC 20-28V DC 300mA 265mA 565mA Protection rating IP65 Energy 5 joules (5Ws) - 5 joules (5Ws) Boxed weight Red Flash Rate 1Hz (60 fpm) - 1Hz (60 fpm) Body Colours Red, Amber, Clear Sound Output (nominal) at 1m +/- 3dB – Tone 2 - 110dB(A) 110dB(A) Number of Tones - 32 32 -50 to +70°C -50 to +70°C -50 to +70°C Protection rating P66/67 IP66/67 I P66/67 Boxed weight 2.45Kg 3.2Kg 4.8Kg Item Numbers I.S. Sounder Red Body I.S. Beacon Red Body, Red Lens I.S. Beacon Red Body, Amber Lens I.S. Beacon Red Body, Clear Lens I.S. Sounder Beacon Red Body, Red Lens I.S. Sounder Beacon Red Body, Amber Lens I.S. Sounder Beacon Red Body, Clear Lens Sounder/Beacon Solenoid Driver Single Channel Sounder/Beacon Solenoid Driver Dual Channel Sounder Circuit Zener Barrier www.ampac.net Temperature range 205-0114 208-0201 208-0202 208-0203 205-0111 205-0115 205-0116 205-0112 205-0117 205-0118 Body Colours Red Item Numbers BEx Flameproof Sounder Red Body BEx Flameproof Beacon Red Body, Red Lens BEx Flameproof Sounder Beacon Red Body, Red Lens 205-0113 208-0200 205-0110 www.ampac.net 94 Cable 95 2 Core TPS Cable Specifications Item Number 9000-4201-0200 Cross Section mm2 Conductor Strands/ Dia Core Configuration Stripe Colour Overall Size mm Std Drum Length Std Drum Length 0.75 7 / 0.37 Flat - 6.2 x 4.0 200M 50 9000-4201-0500 0.75 7 / 0.37 Flat - 6.2 x 4.0 500M 50 9000-4202-0200 0.75 7 / 0.37 Flat White 6.2 x 4.0 200M 50 9000-4202-0500 0.75 7 / 0.37 Flat White 6.2 x 4.0 500M 50 9000-4203-0200 0.75 7 / 0.37 Flat Yellow 6.2 x 4.0 200M 50 9000-4203-0500 0.75 7 / 0.37 Flat Yellow 6.2 x 4.0 500M 50 9000-4204-0200 0.75 7 / 0.37 Flat Blue 6.2 x 4.0 200M 50 9000-4204-0500 0.75 7 / 0.37 Flat Blue 6.2 x 4.0 500M 50 9000-4205-0200 1.0 7 / 0.43 Flat White 7.1 x 4.2 200M 54 9000-4205-0500 1.0 7 / 0.43 Flat White 7.1 x 4.2 500M 54 9000-4206-0200 1.5 7 / 0.505 Flat - 8.0 x 5.0 200M 75 9000-4206-0500 1.5 7 / 0.505 Flat - 8.0 x 5.0 500M 75 9000-4207-0200 1.5 7 / 0.505 Flat White 8.0 x 5.0 200M 75 9000-4207-0500 1.5 7 / 0.505 Flat White 8.0 x 5.0 500M 75 9000-5203-0200 1.5 7 / 0.505 Twisted - 7.5 x 6.5 200M 80 9000-5203-0500 1.5 7 / 0.505 Twisted - 7.5 x 6.5 500M 80 9000-6203-0200 1.5 7 / 0.505 Screened - 7.6 200M 93 9000-6203-0500 1.5 7 / 0.505 Screened - 7.6 500M 93 Product Overview AMPAC Safety’s CableSAFE cables are manufactured and approved for use in Fire Detection and Emergency Warning Systems. CableSAFE cables are available with coloured sheath stripes on Red Sheath to differentiate between detector and ancillary circuits. A twisted version is available for use in addressable loop cabling when reduced line noise is essential. •• •• •• •• •• •• •• Red Sheath for Fire Alarm Application as specified for Fire Alarm use White, blue or yellow stripe on red sheath for fire related systems StripEasy Sheath Metre markings Available in flat and twisted AS/CAS008 compliant 200m and 500m rolls available Approved to: AS/NZS5000.2 Cable Construction AS/CAS008 ACMA Compliance N31145 AS/NZS1125 Conductors AS/NZS3808 Insulation & Sheath Applications Fire Systems Warning Systems •• •• •• •• •• •• •• •• •• •• •• Addressable Loop Addressable Interfaces Conventional Zones Sounders & Bells Door Holders Remote Indicators Agent Release Warning Signs www.ampac.net Ceiling Speakers Horn Speakers Visual Warning Devices Item Numbers 2 Core TPS Cable TPS Flat 2c 0.75mm‚ - 200M TPS Flat 2c 0.75mm‚ - 500M TPS Flat 2c 0.75mm‚ White Stripe - 200M TPS Flat 2c 0.75mm‚ White Stripe -500M TPS Flat 2c 0.75mm Yelllow Stripe - 200M TPS Flat 2c 0.75mm Yelow Stripe - 500M TPS Flat 2c 0.75mm Blue Stripe - 200M TPS Flat 2c 0.75mm Blue Stripe - 500M TPS Flat 2c 1.0mm‚ White Stripe - 200M TPS Flat 2c 1.0mm‚ White Stripe - 500M TPS Flat 2c 1.5mm‚ - 200M TPS Flat 2c 1.5mm‚ - 500M TPS Flat 2c 1.5mm‚ White Stripe -200M TPS Flat 2c 1.5mm‚ White Stripe - 500M 9000-4201-0200 9000-4201-0500 9000-4202-0200 9000-4202-0500 9000-4203-0200 9000-4203-0500 9000-4204-0200 9000-4204-0500 9000-4205-0200 9000-4205-0500 9000-4206-0200 9000-4206-0500 9000-4207-0200 9000-4207-0500 TPS Twisted 2c 1.5mm‚ - 200M TPS Twisted 2c 1.5mm‚ - 500M TPS Twisted Screen 2c 1.5mm‚ -200M TPS Twisted Screen 2c 1.5mm‚ - 500M 9000-5203-0200 9000-5203-0500 9000-6203-0200 9000-6203-0500 2 Core TPS Cable Halogen Free TPS Flat Hal Free 2c 1.5mm- 500M TPS Twisted Hal Free 2c 1.5mm - 200M 9000-7203-0500 9000-8203-0500 www.ampac.net 96 Ancillaries Ancillaries 97 Electro-Magnetic Door Holders Electro Magnetic Door Retainer The AMPAC Door Retainer enables doors to be held open under normal conditions and released during a fire alarm condition. They are simple to install and commission and are suited to a wide range of applications including Hospitals, Schools, Manufacturing Plants and Office Buildings. Operating Voltage 15 to 29 VDC Operating Current 55mA @ 24 VDC Holding Force 50kg Housing White High Temperature ABS Operating Temperature -10° to +55° C Dimension (mm) 100h x 100w x 50d IP rating IP 51 Weight 750 g ApprovalC-Tick Ampac Door Holder 24VDC 50KG 212-0012 Surface Mount Door Holder The Surface Mount Door Holders combine good looks, high performance and economy in a low profile package. Designed to allow doors to be held open under normal conditions and released during a fire alarm condition, the Surface Mount Door Holders are simple to install and commission and are suited to a wide range of applications including: Product Overview Ampac offers a wide range of Ancillary devices for use in conjunction with its range of intelligent and conventional detectors and control panels. A versatile and functional range offering a huge choice for any application. Products incude: •• •• •• •• •• •• E lectro magnetic door retainters MultiAmp PSU Key Holders Wall Boxes Document cabinets Sealed Rechargable Lead-Acid Batteries www.ampac.net 4101- 1001/3/4 1002/5 Operating Voltage 24V dc 230V ac Current 50mA 12mA Dimensions (mm) ABS 87 W x 95 H x 46 D Steel 86 W x 86 H x 62 D Manual Release Yes Operating Temp. -10° to +50°C IP rating IP51 Finish White Fire Resistant ABS ApprovalsEN1155 Surface Mount 200N 24V ABS Case Door Holder Surface Mount 200N 230V ABS Case Door Holder Surface Mount 500N 24V ABS Case Door Holder Surface Mount 200N 24V Steel Case Door Holder Surface Mount 200N 230V Steel Case Door Holder Adjustable Keeper Plate 4101-1001 4101-1002 4101-1003 4101-1004 4101-1005 4101-6004 www.ampac.net 98 Ancillaries 99 Electro-Magnetic Door Holders Flush or Surface Mount- Metal Case Universal Door Holder The Flush Mount Door Holder is built around a robust fascia plate for flush mounting on a back box. The Surface Mount unit is supplied with a back box incorporating 20mm knockouts. Designed to allow doors to be held open under normal conditions and released during a fire alarm condition, the Door Holders are simple to install and commission and are suited to a wide range of applications including: The Universal Door Holder is designed for floor, ceiling or wall mount applications and enables doors to be held open under normal conditions and released during a fire alarm condition. The Universal Door Holder is simple to install and commission and is suited to a wide range of applications including: 4101- 3001/1004 3005/1005 Operating Voltage 24V dc 230V ac Current 50mA 12mA Dimensions (mm) Flush Mount 86 W x 86 H x 43 D Surface Mount 86 W x 86 H x 62 D Manual Release Yes Operating Temp -10° to +50°C IP rating IP51 Finish Nickel Coated Painted White ApprovalsEN1155 Flush Mount 200N 24Vdc Door Holder Flush Mount 200N 230Vac Door Holder 4101-3001 4101-3005 Universal Mount 500N Short Stand 24V Door Holder Universal Mount 500N Long Stand 24V Door Holder Universal Mount 1000N Short Stand 24V Door Holder Universal Mount 1000N Long Stand 24V Door Holder 4101-4001 4101-4002 4101-4003 4101-4004 Floor Mount Door Holder Decorative Flush or Surface Mount The Floor Mount Door Holder features rugged cast aluminium housing, a holding electromagnet with integral anti-residual ejection pin and a manual release switch. Decorative Door Holders are particularly suitable for installation in prestigious projects such as Hotels, Offices, Historical Buildings and Museums. Built around a robust fascia plate for flush mounting and supplied with a back box, the Door Holders are available in Bright Chrome, Lacquered Brass or Stainless Steel finish with matching Decorative Keeper Plate. 4101- 2001/3 4 1002/4 Operating Voltage 24V dc Current 45mA 90mA Dimensions (mm) 110 W x 95 H x 96 D Manual Release Yes Operating Temp. -10° to +50°C IP rating P51 Finish Aluminium White Housing Zinc Plated Magnet Approval EN1155 Floor Mount 200N 24V Cast Aluminium Door Holder Floor Mount 500N 24V Cast Aluminium Door Holder Floor Mount 200N 24V Vandal Proof Door Holder Floor Mount 500N 24V Vandal Proof Door Holder www.ampac.net 4101- 4001 / 02 4003 / 04 Operating Voltage 24V dc Current 43mA 76mA Stand Length (mm) Floor Mount H1 183 / 282 Steel 250 / 350 Manual Release Yes Operating Temp -10° to +50°C IP rating IP51 Finish Nickel Coated Painted White ApprovalEN1155 * For product specifications, please refer to the Product Data Sheet. 4101-2001 4101-2002 4101-2003 4101-2004 4101- Operating Voltage Current Dimensions (mm) Flush Mount Surface Mount Manual Release Operating Temp. IP rating Approval 3002/03/04 24V dc 50mA 3006/07/08 230V ac 12mA 86 W x 86 H x 24 D 86 W x 86 H x 62 D Yes -10° to +50°C IP51 EN115 Chrome Flush Mount 24V Door Holder Brass Flush Mount 24V Door Holder Stainless Steel Flush Mount 24V Door Holder Chrome Flush Mount 230V Door Holder Brass Flush Mount 230V Door Holder Stainless Steel Flush Mount 230V Door Holder Chrome Surface Mount Kit Brass Surface Mount Kit Stainless Steel Surface Mount Kit Brass Keeper Plate Stainless Steel Keeper Plate Bright Chrome Keeper Plate 4101-3002 4101-3003 4101-3004 4101-3006 4101-3007 4101-3008 4101-6005 4101-6006 4101-6007 4101-6008 4101-6009 4101-6010 www.ampac.net 100 Ancillaries 101 Electro-Magnetic Door Holders Power Supplies Weatherproof IP65 MultiAmp-DH The Weatherproof Door Holder is ideal for most applications in all types of buildings while its high level of ingress protection means it is particularly suited to use outdoors and in marine type applications. Remotely releases fire doors held open by electro magnetic door holder. Operating Voltage Current Dimensions (mm) Assembly Keeper Plate Magnet Weight Manual Release Operating Temp. IP rating Finish IP65 Protected 1200N 24Vdc IP65 Protected 1200N 230Vac 4101-5001 24V dc 300mA 4101-5002 230V ac 45mA Ø 102 x 45 Ø 89 x 42 2.0kg No -10° to +50°C IP65 Zinc Plated Steel Material High Impact ABS FinishWhite Dimension (Recessed) 91mm H X 149mm W x 40mm D (Surface) 91mm H X 149mm W x 53mm D Weight 400g packed Mains Supply Voltage 230 VAC +/- 10% @ 47-63Hz Door Holder Output Voltage 24 VDC @ 250mA Operating Temperature -5° to +45° C Relative Humidity 25% to 95% MultiAmp-DH 250MA Flush Mount MultiAmp-DH 250MA Surface Mount 4510-1100 4510-1101 4101-5001 4101-5002 Floor Mount Bracket A floor mounting bracket is available for the Surface Mount Door Holders. With this the Door Holder can be mounted in any convenient position on the floor to suit the door. It is supplied in a white finish with mounting instructions and is compatible with standard conduit back boxes. Floor Mounting Bracket 4101-6001 Remote Door Release Remotely releases fire doors held open by electro magnetic door holder. Remote Door Release Plate Vertical Screen Remote Door Release Plate Horizontal Screen 268-0003 268-0010 Chain Keeper Plate The Chain Keeper enables a wall mounted electromagnetic door holder to be used even when the door will not open fully to meet the magnet. It is a very flexible solution to awkward mounting. A one metre length of chain is supplied as standard. Keeper Plate and Mounting with 1M Chain 4101-6002 Document Cabinets AMPAC offers ABS and metal document cabinets designed to complement the range of AMPAC’s fire control panels. The cabinets can hold in excess of 100 A4 sheets of fire and security information relevant to the premises. Low Profile Keeper Plate The non-adjustable, slim style keeper plate is for use with 200N Door Holders. It is an alternative to the standard adjustable keeper design where the gap between the door and the magnet needs to be kept to a minimum. Low Profile Keeper Plate 200N www.ampac.net 4101-6003 Dimensions IP Rating Weight Document Cabinet ABS Document Cabinet Metal Cool Grey Document Cabinet Metal White ABS – 300mm H x 360mm W x 100mm D Metal – 295mm H x 356mm W x 92mm D IP30 ABS – 1kg Metal – 3kg 4210-0010 4210-0020 4210-0021 www.ampac.net 102 Ancillaries 103 Power Supplies Batteries Sealed Rechargeable Lead-Acid Batteries Ampac sells a comprehensive battery range for all applications requiring a reliable rechargeable power source. The wide range of sizes coupled with good cycling ability make them perfect for critical systems such as fire alarm and emergency warning systems. Designed using VRLA technology, negating the need to add water, these batteries can be applied in many critical systems requiring reliable reserve power. Available as 12V or for very large systems 2 volt cells (x12). Extra large 12 Volt (consideration of battery cabinet space required) Product Overview The MultiAmp PSU range of power supplies has been specifically designed for Fire System Installations and features intelligent battery charging and monitoring with remote fault signalling. Available in 2A, 5A or 10A versions, the MultiAmp PSU range of switch mode power supplies has been specifically designed for use with compliant fire detection and alarm systems. The units include intelligent battery charging using efficient EcoCharge technology, possess mains & battery monitoring with independent voltage free relay outputs. The units also feature battery deep discharge protection in the event of a prolonged mains failure. The inclusion of LED indicators provides quick diagnostics of the status of the power supply, while a variety of enclosures offer the installer a choice of standby battery backup options. •• •• •• •• •• •• •• 27.6V dc output Energy efficient operation Cost effective switch mode technology Intelligent battery charging and monitoring technology with Deep discharge protection Mains AC transient protection Remote fault signalling Space for addressable loop interface module Output (mains on) 27.6Vdc Load Output 2.0, 5.0 & 10.0 Amps Mains Supply 110V ac to 230V ac @ 50Hz Environment -10°C to 40°C @ 75%RH Dimensions (mm) 12Ahr Enclosure 330W x 280H x 121D 38Ahr Enclosure 425W x 400H x 216D 65Ahr Enclosure 425W x 680H x 216D IP rating IP30 Material 1.6mm Mild Steel Finish Power coated - Surf Mist Approval Complies with AS7240.4 www.ampac.net 210-0008 210-0006 210-0016 210-0010 210-0003 210-0012 210-0013 210-0015 210-0004 12V 100AH SLA Battery 12V 160AH SLA Battery 12V 150AH SLA Battery 12V 230AH SLA Battery 210-0002 210-0022 210-0017 210-0011 2V 250AH SLA Battery 2V 300AH SLA Battery 2V 500AH SLA Battery 210-0018 210-0019 210-0020 Test Equipment Detector Test Equipment •• •• •• •• Item Numbers 2 Amp PSU - Space for 2 x 12Ahr Batts 2 Amp PSU - Space for 2 x 38Ahr Batts 5 Amp PSU - Space for 2 x 38Ahr Batts 10 Amp PSU - Space for 2 x 38Ahr Batts 5 Amp PSU - Space for 2 x 65Ahr Batts 10 Amp PSU - Space for 2 x 65Ahr Batts 12V 1.3AH SLA Battery 12V 3.2AH SLA Battery 12V 7AH SLA Battery 12V 12AH SLA Battery 12V 18AH SLA Battery 12V 26AH SLA Battery 12V 40AH SLA Battery 12V 65AH SLA Battery 12V 75AH SLA Battery 4510-8102 4510-8202 4510-8205 4510-8210 4510-8305 4510-8310 Access poles are used with interchangeable heads that fit onto the end of the pole. The equipment is suitable for use on a wide range of detectors. Poles are telescopic, nonconductive, toughened fibreglass. Light weight and simple to use Telescopic Pole 2.5M To 4 mtrs Single Extension Pole - 1.13M Universal Detector Removal Tool Smoke Detector Test Dispenser Heat Detector Tester 240V AC Heat Detector Tester - cordless (head only) Smoke Detector Test Set - 8.2 metre Smoke & Mains Heat Tester Set - 6 metre Smoke & Cordless Heat Tester Set - 4.5 metre Battery Baton for Cordless Heat Tester Smoke Detector Test Gas 250ml Aerosol Test Gas Can Smoke 150ML (Handheld) Carbon Monoxide Smoke Can Detector Tester (Test Pole) 204-0001 204-0002 204-0003 204-0004 204-0005 204-0017 204-0009 204-0010 204-0018 204-0021 204-0014 204-0015 204-0020 www.ampac.net 104 Ancillaries 105 Test Equipment Ancillary Equipment Smoke Pen Wall Boxes The Smoke Pen kit has been designed to provide a smooth, thin, non-volatile smoke stream and is ideal for testing High Sensitivity Smoke Detectors promoted by Ampac. The Smoke Pen incorporates a purpose designed dispenser which safely retains the smoke stick for easy use during serving and commissioning of aspirating systems. Each kit comes complete with five (5) smoke sticks offering over 4 hours of smoke stop/re-start usage) •• •• •• Smoke Pen 204-0030 Used for flush mounting devices such as manual call points and sounders Suitable for MCP models ACP-01 & FP2 Suitable for ‘Vara’ sounder Size Metal Plastic Weight Metal Plastic Wall Box Metal 25mm Deep for MCPs Wall Box Plastic 35mm Deep for MCPs 268-0002 268-0009 Detector Base – Mounting Block Flame Sensor Test Unit and Case The Flame Sensor Test Kit is a tool which is designed to test flame detectors without the need of real flames. Flame Sensor Test Unit and Case 72mm H x 72mm W x 47mm D 72mm H x 72mm W x 35mm D 153 grams 47 grams 29600-226 •• The mounting block is recommended for use when detectors are installed on uneven surfaces •• The mounting block ensures the correct fit with the base and the detector, improves reliability and ensures that the mounting tags on the base are not overtightened •• Used with Base Mounted Flame Detector Mounting Block For S65 / XP95 Base 201-0192 Void Fire Detector Holder The Void Fire Detector Holder allows the installation of a fire detector within a sealed ceiling space at variable heights. The holder enables easy inspection and maintenance of the fire detector located within the ceiling void space from below ceiling level. Discovery Programmer The Discovery Programmer is a portable test and configuration tool for Discovery smoke and heat detectors Discovery Programmer 53832-030 EUR Three models are available to suit various ceiling void heights from 0.6 metres to 3 metres. •• •• •• •• Adjustable mounting tubes Aesthetically pleasing Fixing brackets included Removable ceiling plate Void Detector Holder 1 Metre Void Detector Holder 2 Metre Void Detector Holder 3 Metre Key Holder – D2 Wilco Detector Bracket •• •• •• •• •• The Willco Detector Bracket has been designed to allow installation of fire detectors within a concealed ceiling space at variable heights. The bracket assembly enables easy inspection and maintenance of the fire detector from below ceiling level. Installation is quick and easy using the existing designated false ceiling hanger along with readily available 20mm electrical conduit (not supplied). Provides a visible place to locate a key used for emergency access Red finish Instructions on glass Break glass operation similar to a manual call point Suitable for indoor use Size 100mm Dia x 32mm D FinishRed Weight 130 grams Break Glass Key Holder D2 D2 Key Box Holder Spare Glass KP-308 www.ampac.net 4112-2001 4112-2002 4112-2003 •• •• •• 215-0003 215-0004 Adjustable mounting heights 3 x Height adjustment brackets included Manufactured from Galvanised Steel Wilco Detector Bracket 4112-2008 www.ampac.net 106 Ancillaries 107 Ancillary Equipment Deckhead Mounting Boxes The Deckhead Mounting Box gives extra protection to devices to be fitted in areas where there is the possibility of moisture or condensation ingressing through the rear of the base. The new version is suitable for a wider range of detector bases as well as Apollo’s AV bases. •• •• •• Protects against water ingress. Improved performance. Available in polycarbonate or metal. Deckhead Mounting Box Metal Deckhead Mounting Box with PG16 Access Ports Metal Deckhead Mounting Box with M20 Access Ports Deckhead Adaptor (for use with 29600-196 - converts cable glands from PG16 to M20) 201-0193 201-0195 201-0194 27249-005 Head Office - Perth Ampac Technologies Pty Ltd 7 Ledgar Road, Balcatta, Western Australia, 6021 Telephone: +618 9201 6100 Fax: +618 9201 6101 Email: [email protected] Web: www.ampac.net Australia New South Wales & Australian Capital Territory Unit B, 28–32 Egerton Street, Silverwater, New South Wales, 2128 T: +612 8866 6200 F: +612 9648 4932 E: [email protected] Northern Territory 2/10 Cato St, Winnellie, Northern Territory, 0820 T: +618 8911 1260 F: +618 8911 1261 E: [email protected] Queensland 1/53 Parramatta Road, Underwood, Queensland, 4119 T: +617 3462 5700 F: +617 3208 9355 E: [email protected] South Australia 63 Grange Road, Welland, South Australia, 5007 T: +618 8246 3800 F: +618 8340 4218 E: [email protected] Victoria & Tasmania 345 Darebin Road, Thornbury, Victoria, 3071 T: +613 8459 3300 F: +613 8459 3301 E: [email protected] As part of Ampac’s commitment to continuous improvement, specifications may change without notice. Version 15/09/15 www.ampac.net
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement