eCATALOGUE NEW ZEALAND WOR LD LEA D ER O F INNOVATIV E SOLUTIO NS IN FIRE DETECT I O N AN D AL ARM S YS T E MS NZ / PAGE 1 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT AMPAC PACIFIC Ampac Pacific is a wholly owned subsidiary of Ampac Technologies Pty Ltd. Ampac is an independent privately owned manufacturer and supplier of fire detection and alarm systems. Ampac prides itself on high quality personalised customer service. Our core business operations involve sales and marketing, R&D, manufacturing and distribution of a complete range of fire alarm and warning system solutions. CONTROL PANELS We supply systems for a large variety of applications, eg commercial and industrial buildings, government buildings, prisons, hospitals, hotels and multi residential complexes to name just a few. Ampac Pacific operates from a Customer Service Office based in Glenfield, Auckland. Comprising of a team of dedicated and experienced employees, Ampac Pacific provides sales and technical support for fire installation and EWIS contractors as well as fire discipline and electrical consulting engineers. We also work with building owners and maintenance companies to make ‘manufacturers recommendations’ towards future planning and budgeting options. NEW 3 NZ Series Conventional ZoneSense NZ1/NZ1R Conventional NZ400 Conventional NZ3200 Conventional LoopSense Intelligent FireFinder Conventional/Intelligent ZoneSense PLUS AR Agent Release 3 4 7 9 12 16 36 EMERGENCY WARNING SYSTEMS 39 EV3000 Emergency Warning System Speakers 39 47 GRAPHICS SYSTEM 50 SmartGraphicsHD 50 DETECTORS52 Series 65 Conventional Orbis Conventional Ampac Detectors XP95 Intelligent Discovery Intelligent Since our inception back in 1974, and 1996 in Auckland, Ampac has grown to become a thriving global business operation with its focus on quality products and exceptional customer service and support. Our passion for growing our business through the relationships we have with our customers is one that energises us. It fuels our desire to make better products, implement more efficient systems, grow our network of operations and develop our people. 52 56 61 62 68 INTERFACES77 Ampac’s range of products enables us to deliver complete solutions for Fire Detection and alarm systems of any size and for any customer. Developing unparalleled customer partnerships drives our desire to be ‘World leaders of Innovative Solutions in Fire Detection and Alarm Systems’. Ampac I/O Devices Apollo I/O Devices 78 83 AUDIO VISUAL SIGNALLING 91 XP95/Discovery Sounders, Beacons & Sounder Beacons inc Bases Ampac Bells, Strobes & Remote Indicators Electronic Sounders, Beacons & Bases ANCILLARIES105 Power Supplies Manual Call Points Electro-Magnetic Door Holders Document Cabinets Test Equipment NZ / PAGE 2 CONTACT AMPAC HOME 92 97 103 CONTENTS SEARCH ZOOM 106 108 111 115 116 PRINT EXIT CONTROL PANELS NZ Series Conventional Control Panels Ampac supplies a wide range of conventional fire indicator panel options which meet the latest NZ standards. Each panel model is designed to be user-friendly as well as cost-effective. Our product line up includes: • N Z1 Single Zone Detection • NZ400 Four Zone Detection • NZ3200 Applications between 8 and up to 32 Zones The panel selected should be chosen based on the number of zones required and the overall feature set required. Your choice should also accommodate any future plans for the site. A series of add on kits are available with NZ400 and NZ3200 models to maximise the cost effectiveness and flexibility of each product. Other conventional system solutions If the NZ series outlined above does not meet your particular needs, for instance you need a larger conventional system or perhaps the system needs to be networked, the Ampac FireFinder will meet such applications. FireFinder offers a modular 16 zone architecture and or addressable loop option, ie 16, 32, 48, 64 zones, etc, and can be networked to other Ampac FireFinder panels where necessary. Whatever your needs are, please don’t hesitate to contact your local Ampac customer service office . NZ / PAGE 3 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS ZoneSense NZ1/NZ1R Conventional Fire Alarm Control Panel The ZoneSense NZ1 is a single zone Fire Alarm Control Panel. The prolonged standby time makes the system particularly suitable for non monitored applications. The facility to provide alarm verification and smoke detector only response reduces unwanted alarms.The ZoneSense NZ1 is designed for commercial applications and has been approved to NZS4512:2003. The ZoneSense NZ1R is designed for residential applications and has a ‘Reset’ facility on the front panel. This allows the end user to reset the panel from an alarm state without having to open the door. • Single Fire detection zone • Commercial and Residential version available • Simple to install and set up • Long stand by time (240hrs) • High Bell current output • Front Service • Complies with NZS4512:2003 (NZ1 only) NZ / PAGE 4 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS NZ1 Conventional ZoneSense NZ1 (Commercial) ABS Complies with NZ4512:2003 ZoneSense NZ1R (Residential) Metal Power Supply Mains Supply Operating Voltage Supply Current Quiescent Current Battery Capacity 230 VAC ± 10% @ 0.5 A 12 VDC 500 mA 22 mA 1 x 12V 7AHr Environmental Operating Temperature Relative Humidity -5°C to 55°C 25% - 75% Zone Detection Circuit No of Zones Zone Monitoring Zone Quiescent current End Of Line (EOL) No of Detectors Max Cable length One (1) x 2 wire system Open and Short Circuit 40 mA @ 24 VDC, 3K3Ω EOL 3K3Ω EOL 40 3km (based on cable resistive and capacitive values of 50Ω and 1uF respectively) Outputs Alarm Outputs (monitored) Auxiliary Fire Auxiliary Defect Programmable Relay 1.5A @ 12VDC 10KΩ EOL Open collector 30mA (max) @ 12VDC Open collector 30mA (max) @ 12VDC NO,C,NC Contact rating: 1A @ 30VDC Miscellaneous Sprinkler Input (monitored) Closing contact to operate. 10KΩ EOL Mechanical Material: ABS Cabinet (BX1) Metal Cabinet (BX10) Finish: ABS Cabinet (BX1) Metal Cabinet (BX10) NZ / PAGE 5 CONTACT AMPAC HOME CONTENTS SEARCH ABS/Blend High Impact 1.2mm Mild Steel ABS Light grey Metal Oyster matt Ripple ZOOM PRINT EXIT CONTROL PANELS NZ1 Conventional Mechanical (continued) ABS Cabinet (BX1) Metal Cabinet (BX10) Packed Weight packed excluding Batteries 300mm (H) x 360mm (W) x 100mm (D) 300mm (H) x 360mm (W) x 100mm (D) 310mm (H) x 500mm (W) x 110mm (D) ABS 3kg Metal 5.2kg ZoneSense NZ1 (Commercial) BX1 ZoneSense NZ1 (Commercial) BX10 ZoneSense NZ1R (Residential) BX1 ZoneSense NZ1R (Residential) BX10 BX10 Surround ZoneSense NZ1 (Commercial) ABS Complies with NZ4512:2003 NZ / PAGE 6 CONTACT AMPAC 2655-0100 2655-0101 2655-0150 2655-0151 ENC3016-A ZoneSense NZ1 (Residential) Metal HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS NZ400 Conventional Fire Indicator Panel The NZ400 is an automatic Fire Alarm Control Panel. The NZ400 has four 2-wire fire detection circuits able to accommodate heat detectors, smoke detectors, manual call points or a combination of these devices. Programming and interrogating the panel configuration is made easy with the inclusion of a seven-segment display. Acrylic index can be easily fitted or removed. The index is back lit. The NZ400 has two bell outputs to alert personnel in the event of a fire. These outputs are monitored for short and open circuit conditions. With the addition of an SGD Type II board the system can signal the brigade. Up to four (4) programmable relays can be added to the panel using the serial relay board. • Four detection zones plus DBA input • Available in Front or Rear Service • Supports ATS connection • Programmable zone response – only AVF • Zones selectable for Bell / Brigade calling • Event Log (Last 8 events) • Earth leakage monitoring (selectable) • Mains present monitoring (selectable) • Double Knock (grouping zones) • Back lighting for index • Defect Buzzer selectable • Complies with NZS4512:2003 NZ / PAGE 7 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS NZ400 Conventional NZ400 Front Service NZ400 Rear Service Input Detector Circuit (4) 1.6mA @ 24 VDC Output Bell 1 Bell 2 Auxiliary Power Brigade Serial relay 2A @ 12 VDC (fused) 2A @ 12 VDC (fused) 800mA @ 12 VDC (fused) Type II SGD Programmable (max 4) Mechanical Material Finish Dimension Weight 1.2mm Mild Steel Arch White Powder Coat 320H x 350W x 80D mm 4.5kg (no batteries) Electrical Mains Supply Operating Voltage Supply Current Quiescent Current Battery Capacity 230 VAC ± 10% @ 0.5A 12VDC 500mA (max) 60mA 1 x 12V 7Ahr Approvals Approvals NZS4512:2003, Opus NZ400 Conventional Indicator Panel Front Service EV20W + Batteries NZ400 Conventional Indicator Panel Rear Service EV20W + Batteries Type II SGD 8-way Relay Board Serial Relay Board NZ / PAGE 8 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 5155-0200 5155-0250 155-0001 155-0003 155-0015 EXIT CONTROL PANELS NZ3200 Conventional Fire Indicator Panel The NZ3200 is a Fire Alarm Control Panel that is available in 8, 16, 24 or 32 zone versions. Each of the zones interfaces with conventional two wire detectors. The NZ3200 is offered with two different size cabinets with capacities of 16 and 32 zones respectively. Programming the system options is via an easy to use DIP switch. All common system and zone alarm LED’s can be remotely displayed with the addition of a simple plug in RS485 remote mimic option. The easy to remove / fit acrylic index is provided with built in back lighting to make compliance with New Zealand installation requirements as easy as possible. • 8, 16, 24 or 32 detection zones • Available in Front and Rear Service • DBA input • Supports ATS connection • Zones selectable for Bell / Brigade calling • Programmable zone response • Back lighting for index • Defect Buzzer selectable • RS485 remote mimic option • Auxiliary relay with isolate control • Easy expansion with 8 zone modules NZ / PAGE 9 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS NZ3200 Conventional NZ3200 16 Zone Rear Service Front View NZ3200 16 Zone Rear Service Rear View Mechanical Material Finish Dimension Weight 1.6mm Mild Steel 1.6mm Mild Steel White Powder Coat 16 Zone: 450H x 400W x 130D mm 32 Zone: 750H x 400W x 130D mm 16 Zone: 12kg (no batteries) 32 Zone: 17kg (no batteries) Electrical Mains Supply Operating Voltage Supply Current Quiescent Current Battery Capacity 230 VAC ± 10% @ 0.5A 24 VDC 500mA (max) 45 mA 2 x 12V 7Ahr Input Detector Circuit (4) 1.6mA @ 24 VDC DBAMonitored Monitored External Defect Input Unmonitored Door Interlock Input Output Bell 1 Bell 2 Auxiliary Power Auxiliary Relay Brigade Serial relay Remote zone mimic 2A @ 24 VDC 2A @ 24 VDC 1A @ 24 VDC (fused) Volt-free Changeover contact (5A @ 24 VDC) Type II SGD Programmable - 1 (max 4) or 8-way RS485 communications Evac 50 Wrms O/P 2.5A @ 27.4VDC ( 100V Line ) Approvals Approvals NZ4512:2003 NZ / PAGE 10 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS NZ3200 Conventional NZ3200 Conventional Fire Indicator Panel NZ3200 16 Zone Rear Service Front View NZ / PAGE 11 CONTACT AMPAC NZ3200 16 Zone Rear Service Rear View HOME Front Service 8 Zone (16 Zone max) EV50W 8 Zone (32 Zone max) EV50W x 2 5155-0350 5155-0450 Rear Service 8 Zone (16 Zone max) EV50W 8 Zone (32 Zone max) EV50W x 2 5155-0300 5155-0400 NZ3200 Add-On Modules Type II SGD 8-way Relay Board Serial Relay Board Remote Zone Mimic Driver 12 VDC Bell Driver 24 VDC Bell Driver Flow Switch Indicator Bell Monitor Board SGD to SAFE Converter 8-Zone Expansion Board CONTENTS SEARCH 155-0001 155-0003 155-0015 155-0016 155-0017 155-0018 155-0019 155-0027 155-0028 155-0029 ZOOM PRINT EXIT CONTROL PANELS LoopSense Intelligent Control Panel LoopSense is an Intelligent Analogue Addressable Fire Alarm Control Panel. Available in one or two loops, the LoopSense comes packed with options and features that facilitate flexibility, ease of installation and commissioning. • Clear back-lit 40 x 4 line character LCD • Advanced balanced loop design for noise rejection • 500mA loop current • Integrated 32-Zone Indication card • Laptop connection via USB 2.0 or RS232 port • Auto Learn Facility • Removable front door and chassis • LoopMaster – user friendly programming software NZ / PAGE 12 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS LOOPSENSE Intelligent LoopSense – Metal Cabinet (Approved to NZS4512-2010) NZ / PAGE 13 CONTACT AMPAC HOME Power Supply (General) Output Voltage Battery Type (maximum) Battery Discharged Cut Off Voltage 27.5VDC +/- 0.1VDC 17.2Ah 21VDC Base Panel Quiescent Current 1 Loop Panel 2 Loop Panel 115mA 135mA Loop Loop current Detectors/Devices per Loop Cabling Requirements Fault supervision Protocol 500mA max 126 max 2 core 1.5 to 2.5mm O/C, S/C, overcurrent XP95, Discovery Outputs Alarm Sounder Outputs Relay outputs Open Collector Output Auxiliary VDC 4 x supervised/programmable 24VDC @ 500mA max 3 x programmable Voltage free 24VDC @ 1A 2 x programmable – 30mA 2 x protected/programmable 24VDC @ 500mA Inputs Supervised 4 x O/C, S/C, 10K EOL Communications Port Internal to LoopSense External to LoopSense Printer port PC Interfacing RS485 RS485 RS232 or Parallel RS232 or USB 2.0 CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS LOOPSENSE Intelligent Electrical Power Supply Input Voltage Protection Output Current Charger Current 3A PSU version 204 - 264VAC 3Amp M205 3Amps 600mA Environmental Operating temperature Relative humidity IP rating -5°C to +55°C (no icing) 0 to 95% (non condensing) IP30 Mechanical Material Finish Dimensions Weight Approvals NZS4512:2010 LoopSense Intelligent Control Panel LoopSense – Metal Cabinet (Approved to NZS4512-2010) NZ / PAGE 14 CONTACT AMPAC 1.2mm steel Surf Mist Ripple 425H x 400W x 125Dmm 7kg LoopSense, 1 Loop. 3A BX11, Apollo NZS4512 LoopSense, 2 Loop. 3A BX11, Apollo NZS4512 LoopSense, 1 Loop. 3A BX11, Apollo NZS4512 with SGD LoopSense, 2 Loop. 3A BX11, Apollo NZS4512 with SGD Flush Mount Surround for LoopSense Metal 2nd Loop Activation Key HOME CONTENTS SEARCH ZOOM PRINT 8256-0105 8256-0205 8256-0105-0001 8256-0205-0001 ENC 3004-A 8210-0001 EXIT CONTROL PANELS LOOPSENSE Intelligent LED Index • Displays Fire, DBA, Defect and Normal status of the LoopSense CIE •Capable of displaying the alarm status of up to 28 zones •Front or Rear service configurable •A3 size printing area for building layouts •Complies with NZS 4512:2010 •Configurable via LoopMaster Software Approvals: NZS4512-2010 Power Supply Quiescent Current Alarm Current Operating temperature Relative humidity Cabinet Size (mm) Colour Ip Rating 27VDC 5.6mA 39.2mA 0°C to 70°C 0 to 95% (non condensing) 500 (H) x 405 (W) x 70 (D) Surf Mist IP30 28 Zone Mimic Display 8 Zone Red LED Kit (Flying Leads) 4355-0004 4210-0007 LoopSense SmartTerminal Slim Line Repeater • Extends the controls and status of the LoopSense Fire Control Panel •Up to 30 SmartTerminal’s can be connected to each LoopSense Fire Alarm Control Panel •Large LCD with backlight •Internal Buzzer •Flush or surface mountable enclosure •Controls have tactile and audible feedback Mechanical (mm) ABS (BX05) ABS (BX1) Package Weight Power Supply Quiescent Current Maximum Current Operating temperature Relative humidity 195 (H) x 325 (W0 x 50 (D) 300 (H) x 360 (W) x 100 (D) 2.5kg 27VDC 12.5mA (backlight off, buzzer off ) 43.8mA (backlight on, no buzzer) -5°C + 55°C 0 to 95% (non condensing) LoopSense SmartTerminal Repeaters SmartTerminal Repeater without PSU SmartTerminal Repeater with 2 Amp PSU SmartTerminal Slim Line Repeater without PSU NZ / PAGE 15 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 4380-0011 4380-0012 4380-0013 EXIT CONTROL PANELS FireFinder Conventional / Intelligent Fire Alarm Control Panel FireFinder is a state of the art multi microprocessor controlled Intelligent Fire Alarm Control Panel. Modular in design, the FireFinder provides flexibility and versatility that can be configured to operate with both intelligent analogue addressable and conventional devices in the one system. Available in single loop or multiple loop configurations, the FireFinder supports the leading Apollo XP95 and Discovery detector protocols. The Ampac ConfigManager software tools provide a powerful combination with the FireFinder to configure the system operational and functional characteristics of an installation. Enhanced networking capabilities offer the user extended applications with FireFinder incorporating a Master/ Slave Fire control panel arrangement, true Peer to Peer systems, data gathering panels and SmartGraphics a PC based application for the supervision, monitoring and control of larger fire management systems. • • • • • • • • • • • • Clear back-lit 40 character 8 line LCD display Programming options via the front panel or laptop computer Remote system interrogation and diagnostics Extensive Alarm Management resources Self Auto Learn capabilities Day Night sensitivity settings Versatile multi processor architecture Event log and printer options SPOT – Single Person Operation Test Flexible modular expansion and panel Add Ons Optional 32, 64, 96 & 128 zone indicators SmartTerminal repeater options NZ / PAGE 16 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS FIREFINDER Conventional NZS4512 Version FireFinder NZ Conventional Rear View Rear Service Panel Approvals: NZS4512:2003 FireFinder NZ Intelligent Rear View Rear Service Panel Approvals: NZS4512:2003 Outputs Bell 1 (monitored) Switched Switched Bell 2 (monitored) Auxiliary (monitored) Switched Auxiliary (unmonitored) Volt free EWS (monitored) Switched EWS (unmonitored) Volt free Defect Volt free Isolate Volt free Volt free Fire Volt free Valve Monitor Aux DC Fused Volt free Battery Fail 24 VDC 2A 24 VDC 2A 24 VDC 1A 1A @ 24 VDC 24 VDC 1A 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 24 VDC 1A 1A @ 24VDC Indicators Mechanical 1.2mm steel (front) Materials 1.6mm steel (back) ConstructionModular Case Finish Arch White Ripple Dimension 16Z 32Z Weight 16Z 32Z 450H x 400W x 130D mm 753H x 400W x 130D mm 13 kg 20 kg Electrical Power Supply Main Supply Output Voltage Quiescent Current Battery Capacity 230 VAC 27 VDC 450 mA (min.) 12Ah (min.) FireFinder NZ Conventional Rear Service 16 ZONE 16Z INDEX EV50W FireFinder NZ Conventional Rear Service 32 ZONE 32Z INDEX EV50W NZ / PAGE 17 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 112-0011 112-0012 EXIT CONTROL PANELS FIREFINDER Intelligent NZS4512 Version FireFinder NZ Conventional Rear View Rear Service Panel Approvals: NZS4512:2003 FireFinder NZ Intelligent Rear View Rear Service Panel Approvals: NZS4512:2003 Outputs Bell 1 (monitored) Switched Switched Bell 2 (monitored) Auxiliary (monitored) Switched Auxiliary (unmonitored) Volt free EWS (monitored) Switched EWS (unmonitored) Volt free Defect Volt free Isolate Volt free Volt free Fire Volt free Valve Monitor Aux DC Fused Volt free Battery Fail 24 VDC 2A 24 VDC 2A 24 VDC 1A 1A @ 24 VDC 24 VDC 1A 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 24 VDC 1A 1A @ 24VDC Indicators Mechanical 1.2mm steel (front) Materials 1.6mm steel (back) ConstructionModular Case Finish Arch White Ripple Dimension 16Z 32Z Weight 16Z 32Z 450H x 400W x 130D mm 753H x 400W x 130D mm 13 kg 20 kg Electrical Power Supply Main Supply Output Voltage Quiescent Current Battery Capacity 230 VAC 27 VDC 450 mA (min.) 12Ah (min.) FireFinder NZ Intelligent Rear Service 1 Loop 16Z INDEX EV50W FireFinder NZ Intelligent Rear Service 1 Loop 32Z INDEX EV50W NZ / PAGE 18 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 112-0009 112-0010 EXIT CONTROL PANELS FIREFINDER Conventional NZS4512 Version Outputs Bell 1 (monitored) Switched Switched Bell 2 (monitored) Auxiliary (monitored) Switched Auxiliary (unmonitored) Volt free EWS (monitored) Switched EWS (unmonitored) Volt free Defect Volt free Isolate Volt free Volt free Fire Volt free Valve Monitor Aux DC Fused Volt free Battery Fail FireFinder SPIX Conventional Approvals: NZS4512:2003 FireFinder SPIX Intelligent Approvals: NZS4512:2003 24 VDC 2A 24 VDC 2A 24 VDC 1A 1A @ 24 VDC 24 VDC 1A 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 24 VDC 1A 1A @ 24VDC Indicators Mechanical 1.2mm steel Materials ConstructionModular Case Finish Arch White Ripple Dimension 500H x 405W x 145D mm; Anc. Cab. 250H x 405W x 145Dmm Weight 10 kg; Ancillary Cabinet 3 kg Electrical Power Supply Main Supply Output Voltage Quiescent Current Battery Capacity 85-264 VAC 27 Volts 450 mA (min.) 12Ah (min.) FireFinder SP1X 16 Zone FireFinder SP1X Ancillary Cabinet FireFinder SP1X Surround NZ / PAGE 19 CONTACT AMPAC HOME CONTENTS SEARCH 8555-4150 8510-9003 ENC 1798-F ZOOM PRINT EXIT CONTROL PANELS FIREFINDER Intelligent NZS4512 Version Outputs Bell 1 (monitored) Switched Switched Bell 2 (monitored) Auxiliary (monitored) Switched Auxiliary (unmonitored) Volt free EWS (monitored) Switched EWS (unmonitored) Volt free Defect Volt free Isolate Volt free Volt free Fire Volt free Valve Monitor Aux DC Fused Volt free Battery Fail FireFinder SPIX Conventional Approvals: NZS4512:2003 FireFinder SPIX Intelligent Approvals: NZS4512:2003 24 VDC 2A 24 VDC 2A 24 VDC 1A 1A @ 24 VDC 24 VDC 1A 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 24 VDC 1A 1A @ 24VDC Indicators Mechanical 1.2mm steel Materials ConstructionModular Case Finish Arch White Ripple Dimension 500H x 405W x 145D mm; Anc. Cab. 250H x 405W x 145Dmm Weight 10 kg; Ancillary Cabinet 3 kg Electrical Power Supply Main Supply Output Voltage Quiescent Current Battery Capacity 85-264 VAC 27 Volts 450 mA (min.) 12Ah (min.) FireFinder SP1X 1 Loop FireFinder SP1X 2 Loop FireFinder SP1X 3 Loop FireFinder ‘Rack Mount’ (1 Loop Version) FireFinder Even No Loop FireFinder 16Z Conventional AZF Module FireFinder SP1X Ancillary Cabinet FireFinder SP1X Surround NZ / PAGE 20 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 8555-1100 8555-1200 8555-1300 112-0057 159-0001 159-0005 8510-9003 ENC 1798-F PRINT EXIT CONTROL PANELS FIREFINDER Conventional NZS4512 Version Outputs Bell 1 (monitored) Switched Switched Bell 2 (monitored) Auxiliary (monitored) Switched Auxiliary (unmonitored) Volt free EWS (monitored) Switched EWS (unmonitored) Volt free Defect Volt free Isolate Volt free Volt free Fire Volt free Valve Monitor Aux DC Fused Volt free Battery Fail FireFinder SP8X Conventional Approvals: NZS4512:2003 FireFinder SP8X Intelligent Approvals: NZS4512:2003 24 VDC 2A 24 VDC 2A 24 VDC 1A 1A @ 24 VDC 24 VDC 1A 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 24 VDC 1A 1A @ 24VDC Indicators Mechanical 1.2mm steel Materials ConstructionModular Case Finish Arch White Ripple Dimension 500H x 405W x 145Dmm; Anc. Cab. 418H x 515W x 170Dmm Weight 20 kg; Ancillary Cabinet 5 kg Electrical Power Supply Main Supply Output Voltage Quiescent Current Battery Capacity 85-264 VAC 27 Volts 450 mA (min.) 12Ah (min.) FireFinder SP8X 16 Zone FireFinder SP8X 32 Zone FireFinder Even No Loop FireFinder Odd No Loop FireFinder 16Z Conventional AZF Module FireFinder SP8X Ancillary Cabinet FireFinder SP8X Surround FireFinder SP8X + Ancillary Cabinet Surround FireFinder SP8X Agent Release Module NZ / PAGE 21 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 8555-4150 8555-4250 159-0001 159-0003 159-0005 8510-9010 158-0033 158-0027 159-0238 PRINT EXIT CONTROL PANELS FIREFINDER Intelligent NZS4512 Version Outputs Bell 1 (monitored) Switched Switched Bell 2 (monitored) Auxiliary (monitored) Switched Auxiliary (unmonitored) Volt free EWS (monitored) Switched EWS (unmonitored) Volt free Defect Volt free Isolate Volt free Volt free Fire Volt free Valve Monitor Aux DC Fused Volt free Battery Fail FireFinder SP8X Conventional Approvals: NZS4512:2003 FireFinder SP8X Intelligent Approvals: NZS4512:2003 Mechanical 1.2mm steel Materials ConstructionModular Case Finish Arch White Ripple Dimension 500H x 405W x 145Dmm; Anc. Cab. 418H x 515W x 170Dmm Weight 20 kg; Ancillary Cabinet 5 kg Electrical Power Supply Main Supply Output Voltage Quiescent Current Battery Capacity NZ / PAGE 22 CONTACT AMPAC HOME 24 VDC 2A 24 VDC 2A 24 VDC 1A 1A @ 24 VDC 24 VDC 1A 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 1A @ 24 VDC 24 VDC 1A 1A @ 24VDC Indicators CONTENTS SEARCH 85-264 VAC 27 Volts 450 mA (min.) 12Ah (min.) ZOOM PRINT EXIT CONTROL PANELS FIREFINDER Intelligent NZS4512 Version FireFinder SP8X 1 Loop (Fitted) FireFinder SP8X 2 Loops (Fitted) FireFinder SP8X 3 Loops (Fitted) FireFinder SP8X 4 Loops (Fitted) FireFinder SP8X 5 Loops (Fitted) FireFinder SP8X 6 Loops (Fitted) FireFinder SP8X 7 Loops (Fitted) FireFinder SP8X 8 Loops (Fitted) FireFinder Even No Loop FireFinder Odd No Loop FireFinder 16Z Conventional AZF Module FireFinder SP8X Ancillary Cabinet FireFinder SP8X Surround FireFinder SP8X + Ancillary Cabinet Surround FireFinder SP8X Agent Release Module FireFinder SP8X Conventional Approvals: NZS4512:2003 NZ / PAGE 23 CONTACT AMPAC 8555-4100 8555-4200 8555-4300 8555-4400 8555-4500 8555-4600 8555-4700 8555-4800 159-0001 159-0003 159-0005 8510-9010 158-0033 158-0027 159-0238 FireFinder SP8X Intelligent Approvals: NZS4512:2003 HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS FIREFINDER Conventional/Intelligent NZS4512 Version OTHER PANEL SIZES Mechanical Materials 1.2mm steel ConstructionModular Arch White Ripple Case Finish Dimension SP16X 10U 16U 29U 1200H x 625W x 240D mm 700H x 625W x 240D mm 1200H x 700W x 350D mm 1800H x 700W x 350D mm Weight 35 kg 40 kg 90 kg 130 kg SP16X 10U 16U 29U Ancillary Cabinets and Surrounds FireFinder SP1X Ancillary Cabinet FireFinder SP8X Ancillary Cabinet FireFinder SP1X Surround FireFinder SP8X Surround FireFinder SP1X + Ancillary Cabinet Surround FireFinder SP8X + Ancillary Cabinet Surround Battery Box for 10U cabinet NZ / PAGE 24 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 8510-9003 8510-9010 ENC1798-F 158-0033 ENC1797-F 158-0027 158-0006 PRINT EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent Dot Matrix Panel Printer •The dot matrix printer provides hardcopy activity report •Alarms, faults, isolates and system logs may be printed •3 colour status LED •Self test mode •Easy maintenance for replaceable ribbon cassette and paper roll Voltage Quiescent current Character size Operating temperature Relative humidity Weight 5 VDC 1A @ 5 VDC 5 x 7 dots -5°C to +55°C (no icing) 0 to 95% (non condensing) 380 grams Panel Printer 154-0016 SmartTerminal Repeater The SmartTerminal Repeater is an LCD annunciator designed to remotely display the status and provide control of the FireFinder Fire Alarm Control Panel. •Connects to a Communication Driver Board inside the FireFinder Control Panel •4 line by 40 character LCD with backlight and navigation keys UP/ DOWN keys allow the SmartTerminal to be used for FACP operation and interrogation •Buzzer and system Reset •Flush or surface mountable enclosure •Controls have tactile and audible feedback of operation •All terminals cater for 2.5mm cables •Stand alone power supply capabilities •Flush mount kit available (Gyprock toggel fixings) NZ / PAGE 25 CONTACT AMPAC HOME CONTENTS Voltage Quiescent current (backlight/buzzer off ) Max current (backlight/buzzer on) Max distance from main panel Auxiliary output (monitored) Operating temperature Relative humidity SmartTerminal Repeater Size SmartTerminal Slimline Repeater Weight SmartTerminal Repeater SmartTerminal Slimline Repeater 24 VDC 12.4 mA 44 mA 1.2 km 27 VDC 500 mA -5°C to +55°C (no icing) 0 to 95% (non condensing) 300H x 360W x 100Dmm 195H x 324W x 52Dmm 2.5 kg 1 kg SmartTerminal Slimline Repeater without PSU Communication Driver Kit SEARCH ZOOM PRINT 4350-0003 159-0129 EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent Network Interface Card (NIC) – 2 Wire Network •The NIC gives the FireFinder network capabilities via the RS485 communications port •Provides an additional RS232 communications port when connected to Controller Interface Card (CIC) •The NIC can be isolated from other network devices •Loop In/Loop Out for easy installation NE W Voltage Quiescent Current Available Ports Max distance (between NICs) Cable requirements Operating temperature Relative humidity Weight 24 VDC 65 mA RS485 – network 1.2km RS485 – 1 pair twisted/screened -5°C to +55°C (no icing) 0 to 95% (non condensing) 225 grams Network Interface Card – NIC (2 wire) NZ4512 SP1X159-0258 SP8X159-0259 SP16X/Rack159-0260 Add-On Kit 4310-0079 Controller Interface Card (CIC) – 2 Wire •LED driver board •The CIC gives the FireFinder additional RS232 and RS485 capabilities •The RS232 communications port provides for Building Management, ModBus or serial printer •The RS485 communications port provides for Building Management, ModBus or LED repeaters Approvals: C-Tick Voltage Quiescent Current Available Ports Max distance Cable requirements Operating temperature Relative humidity Weight 24 VDC 5 mA RS232 – serial communications RS485 – half duplex multi drop RS232 – 15m RS485 - 1.2km RS232 – 1 pair twisted/screened RS485 – 1 pair twisted/screened -5°C to +55°C (no icing) 0 to 95% (non condensing) 125 grams Controller Interface Card (CIC) NZ / PAGE 26 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 159-0261 PRINT EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent High Level Interface Expander or Port Expander Board The High Level Interface Expander provides the ability for the FireFinder Fire Alarm Control Panels (FACP’s) to support a range of high level interface options. The physical interface between the FACP and equipment can be RS232 or RS485. Typical applications where the HLI Expander is used are: •Building Management •Paging system •Nurse Call Systems •EV3000 •SmartGraphics •MODBUS Supply Voltage Quiescent current Max No. HLIE per FACP controller Size Ports Max Distance Cabling 27VDC 7.5ma 3 155 L x 72.5 W x 20 D mm RS232RS485 15m 1.2kms Multi-core 1 twisted pair + cable+shieldshield FireFinder High Level Interface Expander – Add-On Kit 4310-0080 Analogue Loop Upgrade Kit •This kit adds an intelligent analogue loop to the FireFinder Control Panel •For an odd numbered loop upgrade the kit consists of an I/O CPU module, cable and termination card •An even numbered loop upgrade consists of an I/O CPU module and cable Voltage Quiescent current Loop current Operating temperature Relative humidity Weight 24 VDC 40 mA 250 mA max. -5°C to +55°C (no icing) 0 to 95% (non condensing) 200 grams 1 Loop Upgrade Kit – even numbered loop SP1X 1 Loop Upgrade Kit and processor – odd numbered loop SP1X Even No. Loop SP16X/Rack Even No. Loop SP8 Odd No. Loop SP16X/Rack NZ / PAGE 27 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT 159-0001 159-0003 159-0002 159-0046 159-0004 CONTROL PANELS FIREFINDER Conventional / Intelligent Module Expansion Kit for Modules (5–8) •Expands the capacity of the FireFinder to accommodate a further four loops, 64 conventional zones, four I/O modules or any combination of the above •Requires a main controller board Note: O ther expansion module kits are available with 16AZF/Loop/or I/O modules pre-fitted to suit. Consult your Customer Service office for more details. Voltage Quiescent current Operating temperature Relative humidity Weight 24 VDC 5 mA -5°C to +55°C (no icing) 0 to 95% (non condensing) 110 grams SP8X Loop Module Expansion Kit SP16X/Rack Loop Module Expansion Kit 159-0045 159-0022 8 Way Serial Relay Output Board •Each serial relay output board offers 8 voltage free relay outputs, each rated at 5 amps, 24 VDC •Each relay has a single normally open/close volt-free contact extended to a wire-protected screw terminal •The serial 8-way relay is driven directly from the main controller board Voltage Quiescent current Relay output current Operating temperature Relative humidity Weight 24 VDC 5 mA 5 Amps at 24 VDC -5°C to +55°C (no icing) 0 to 95% (non condensing) 190 grams Rack 8 Way Serial Relay Output Board SPX 8 Way Serial Relay Output Board NZ / PAGE 28 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 159-0072 159-0079 EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent 8-Way 5A Relay •Each upgrade panel add-on offers 8 voltage free relay outputs. E ach output is rated at 5 amps, 24 VDC •Each relay has a single normally open/close volt-free contact extended to a wire-protected screw terminal •The standard 8-way relay upgrade requires spare capacity available on a 128/128 I/O and 16/16 I/O module Voltage Quiescent current Operating temperature Humidity Weight 24 VDC 5 mA (Serial Relay Board) -5°C to 55°C 0 to 95% relative humidity 190 grams SPX 8-Way 5A O/P Relay Rack 8-Way 5A O/P Relay 159-0013 159-0015 8 Way Bell Monitor Board •The 8-Way Bell Monitor has 8 switched 24V DC sounder outputs • The outputs are programmable and monitored for open or short circuit • The board connects directly to the main controller board Voltage Quiescent current Max sounder output current Max output current Operating temperature Relative humidity Weight 24 VDC 20 mA 1 Amp each 4 Amps per board -5°C to +55°C (no icing) 0 to 95% (non condensing) 250 grams 8 Way Bell Monitor Board NZ / PAGE 29 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 159-0071 PRINT EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent 16 Way Conventional Zone Card • Adds 16 conventional Alarm Zone Circuits •Kit consists of an I/O CPU module, cable and 16 zone termination card •Supports up to 40 conventional detectors (Series 60, Series 65 or Orbis) per zone •Fixed 3K3 End-Of-Line device •Supports Ampac NZ detector models Voltage Quiescent current Operating temperature Relative humidity Weight 24 VDC 145 mA -5°C to +55°C (no icing) 0 to 95% (non condensing) 185 grams SP8X/SP16X 16 Way Conventional Zone Card Rack 16 Way Conventional Zone Card 159-0005 159-0006 8 Way Switch and Indicator Card •8 x Push Button On / Off switches •8 x LED display of the On / Off condition •Controls and Monitors solenoid test switches, manual shutdowns and etc. •Switches may be mapped to relays using an AMPAC relay board (4310-0050) •Programmable via ConfigManager for the FireFinder range of panels Voltage24VDC Quiescent Current 3.6mA Max Current 8mA Operating Temperature -5°C - 55°C 0 to 95% relative humidity Humidity Weight100grams Switch and Indicator Card NZ / PAGE 30 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 4310-0030 PRINT EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent 16 Opto Inputs •The Opto Input panel add-on provides 16 programmable electrically isolated inputs to the FACP • The input from a third party source should be a volt-free contact •This upgrade requires spare capacity available on a 128/128 I/O and 16/16 I/O Interconnect Module Voltage Quiescent current Operating temperature Humidity Weight 24 VDC 5 mA -5°C to 55°C 0 to 95% relative humidity 185 grams Rack 16 Opto Input 159-0011 Modem •The modem allows a remote access to FireFinder •Configuration and application software can be uploaded or downloaded via the modem •Wireless Modem requires available signal from appropriate network •All modems are AUSTEL approved •Great tool to provide remote support Voltage Data transfer rate Comms to FACP Operating temperature Humidity Weight 27 VDC 9600 baud max RS 232 -5°C to 55°C 0 to 95% relative humidity SP & Rack: 1kg Wireless: 5kg SPX Modem Rack Modem Wireless Modem NZ / PAGE 31 CONTACT AMPAC HOME CONTENTS SEARCH 159-0033 159-0065 159-0068 ZOOM PRINT EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent Fire Fan Module AS Each Fire Fan Module houses the control and indication of up to four (4) fire fans and a single control/indication for plant trip reset. A hard-wired version of a fire fan module consists of a Fire Fan Control Card and Termination Board. Field wiring is terminated to the termination board at the FACP. A loop-driven version is also available and in this configuration only the Fire Fan Control Card would be required. Field wiring will terminate to address input/output devices that operate on the addressable loop. •Four (4) Controls per Module •Status indication for Run / Fault / Stop •Controls for ON / Auto / Off •Audible and visual feedback of button press •Built in Plant Trip Reset •Easy to Change function of module •Available in Hardware or loop driven versions •Communicates with FACP via RS485 communication port •Where applicable all terminals cater for 2.5mm² cables •Suitable for use with the FireFinder range of panels NZ / PAGE 32 CONTACT AMPAC HOME CONTENTS Operating Voltage Dimensions: Controller Card Termination Board System Capacity: FireFinder LoopSense ZoneSense Plus Contact Rating Approval 27VDC Fits standard Panel Cut-Out 155mm x 72mm 15 Maximum 15 Maximum 1 Maximum 32 @ 24VDC SSL, C-TICK Hard Wired Interface Loop Driven Interface Slip in Label Template SEARCH ZOOM 4310-0021 4310-0071 LAB1486 PRINT EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent Agent Release System AS4214 The Agent Release System comprises of the Main Control Card, Termination Board and Local Control Stations. In addition a yellow Manual Call Point can be supplied to fit to the main Fire Alarm Control Panel (FACP) (This is a requirement of AS4214 Agent Release Systems) The Agent Release System can be configured to operate in a single group or dual group mode. •Controls and Monitors Agent Release System •Outputs for Warning Signs and activation devices •Inputs for signals from pressure switches & valves •Serial connection to Agent Release Local Control Station (LCS) •Programmable via ConfigManager for the FireFinder range of panels Pressure Switch Input Monitored Input Monitored Input Low Pressure Switch Input Monitored Input Interlock Input Gas Fired Output Volt Free Changeover [email protected] System Inoperative Output Volt Free Changeover [email protected] Stage 1 Output Monitored Stage 2 Output Monitored Release Initial Agent Output Monitored current limited 2A max Monitored current limited Release Reserve Agent Output 2A max Agent Release Kit 4310-0010 Local Control Station AS4214 A maximum of 8 LCS's can be connected remote to the panel. An operator may manually release or inhibit release from any of these LCS's. •RS485 serial connection from the FireFinder FACP to the Agent Release Local Control Station (LCS) •A 20mm knock out is provided in the top and bottom of the LCS metal enclosure NZ / PAGE 33 CONTACT AMPAC HOME CONTENTS Inhibit Agent Release Manual release Push button hinged cover MCP with hinged cover Local Control Station SEARCH ZOOM 4310-0019 PRINT EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent Remote Mounted LED Indicators •The remote LED indicator boards provide facilities to mimic the FireFinder zone LEDs and switches •Connects to the RS485 communications bus via the controller interface card •Allows the custom design of geographic site layout mimics •Each termination board connects up to 32 zone LEDs – 31 boards maximum – total 992 zone indications FireFinder LED Mimic Driver Voltage Quiescent current Max current Communication mode Baud rate Communication cable No. of boards No. of zones Buzzer external max current On board status indication Common inputs Operating temperature Relative humidity 27 VDC 8 mA max 100 mA RS485 19200 max 1 x pair twisted and screened 31 max 992 zones max 20 mA Power on – green Normal – green Fault – yellow Reset Lamp test Buzzer mute Bell isolate Manual evacuate -5°C to +55°C (no icing) 0 to 95% (non condensing) FireFinder LED Mimic Driver 32 Way Mimic Output Termination Board FireFinder 16 Zone LED DIsplay Board Mimic Output Termination Board 159-0145 159-0152 159-0218 Remote Expansion LED Board NZ / PAGE 34 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent Fibre Optic Network Interface The fibre optic network interface kit offers the user a method of interconnecting two (2) or more networked FireFinder Fire Alarm Control Panels (FACP) using fibre optic cable as an alternative to copper wire. Each FACP will require a kit. Each kit comprises of 2 modem interfaces plus cables. •4 versions available to suit your cabling scheme on site •Redundant loop integrity (same as copper) •A network interface card is still required at each FACP node • Maximum distance using ‘Multimode’ (between nodes) up to 5km; using Single Mode 50km NZ / PAGE 35 CONTACT AMPAC HOME CONTENTS Supply Voltage 24 VDC 80 mA @ 24 VDC Quiescent Current ST standard Optical Connector Ports Available RS422/RS485 Size (mm) 104D x 104W x 25H Weight280g -20°C to +75°C Operating Temperature 0 to 95% relative, Humidity non-condensing Item FireFinder Fibre Optic Multimode 2 core FireFinder Fibre Optic Multimode 1 core FireFinder Fibre Optic Single mode 2 core FireFinder Fibre Optic Single mode 1 core SEARCH ZOOM PRINT Max Distance between Nodes 5km max 5km max 50km max 50km max EXIT Code 159-0251 159-0252 159-0253 159-0254 CONTROL PANELS ZoneSense PLUS AR Agent Release Panel The ZoneSense PLUS AR (Agent Release) Panel is a dedicated panel for agent release systems. Housed in a metal cabinet, the ZoneSense PLUS AR is available in either four (4) or eight (8) zones. Based on a ZoneSense PLUS Fire Alarm Control Panel (FACP), the AR version is fitted with an Agent Release Panel Add-on (control card and termination board) and a dual action yellow manual call point as standard. The Agent Release panel add-on option is factory set. •Dedicated Agent Release system - purpose built with a host of ancillary products to suit •Comprehensive system status – the AR panel includes a number of system status indicators that facilitates ease of operation and maintenance •Local Control Station with control and indication – mimics full status of the Agent Release panel. An outdoor version of this product is available •User interface and operation based around Industry Fire Emergency procedures – ensures that the system installed is intuitive and easy to use •Dual action Manual Call Point – the yellow MCP is a break glass type and requires a dual action to be activated i.e. lift the protective transparent cover and break the glass •Agent Release Panel is compliant with AS4214 NZ / PAGE 36 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS ZoneSense PLUS AR Fire Alarm Control Panel Operating Voltage Quiescent Current Power Supply Ext Bell Output Warning Sys Output ACF Output ASE Output Fire Alarm Output Fault Output Aux DC Output Reset/Buzzer Communications Output End-Of-Line Values Material Finish Dimension Weight (excluding batteries) ZoneSense PLUS AR 23 to 28 VDC 37 mA (minimum) 27VDC (nominal) @ 2Amps 1A (max) – monitored 1A (max) – monitored 1A (max) – monitored 1A (max) – monitored Volt free 1A @ 24 VDC Open Collector Output Volt free 1A @ 24 VDC Open Collector Output 500mA @ 24 VDC – monitored Open Collector Output RS485 3k3 (fitted as standard), 4k7, 6k8, or 10k ohms, 10μ Farad 1.2 mm mild steel Oyster matt ripple Metal Cabinet: 500H x 405W x 145D mm Metal ancillary cabinet: 250H x 405W x 145D mm 8kg Agent Release System Pressure Switch Input Monitored Input Low Pressure Switch Input Monitored Input Monitored Input Interlock Input Volt Free Changeover Gas Fired Output [email protected] Volt Free Changeover System Inoperative Output [email protected] Stage 1 Output Monitored Stage 2 Output Monitored Release Initial Agent Output Monitored current limited 2A max Release Reserve Agent Output Monitored current limited 2A max ZoneSense PLUS AR 4 Zone NZ / PAGE 37 CONTACT AMPAC HOME CONTENTS SEARCH 2550-0151 ZOOM PRINT EXIT CONTROL PANELS ZoneSense PLUS AR – Ancillary Products Agent Release Warning Signs IP50 Model The AR panel supports a 2-wire connection to warning signs. The 2-wire connection supports both single or dual stage signs. The latter is possible because of the voltage reverse technology adopted by the AR panel. Multiple warning signs may be connected to the AR panel. The connection will be in a ‘daisy chain’ configuration with the last warning sign fitted with an End-Of-Line (EOL) resistor. The EOL resistor facilitates the monitoring of the warning sign circuit. A maximum of 6 warning signs may be fitted to an AR panel. An on-board buzzer fitted to every sign provides audible warning. However in the event AS1670.4 audible warning tones are required, external electronic sounders may be connected directly to each warning sign. An external switch may be connected to the sign to mute audible warning. ACP-04 Manual Call Point Yellow ACP-04 Manual Call Point Hinged Cover IP50 SIGNS Warning sign back box (IP50) no fascia “Extinguishing System Inoperative” complete IP50 Special wording fascia only “Fire Alarm, Do Not Enter” fascia only “Fire Alarm, Evacuate Area” fascia only “Do Not Enter, Gas Discharged” fascia only “Fire Door Closing” fascia Only “Do Not Enter” fascia only IP65 SIGNS Warning sign back box (IP65) no fascia “Extinguishing System Inoperative” complete IP65 Special wording fascia only “Fire Alarm, Do Not Enter” fascia only “Fire Alarm, Evacuate Area” fascia only “Do Not Enter, Gas Discharged” fascia only “Fire Door Closing” fascia only “Do Not Enter fascia only 213-0061 213-0057 207-0050 207-0051 207-0052 207-0053 207-0054 207-0055 207-0056 207-0057 207-0060 207-0061 207-0062 207-0063 207-0064 207-0065 207-0066 207-0067 SOUNDERS Vantage Sounder (Red/White) Vantage Combi (Red/White) IP65 Model 205-0062/63 205-0066/67 Local Control Station Up to four (4) Local Control Stations (LCS) can be connected remote to the AR panel. An operator may manually release, or inhibit release of, the agent from any of these LCS’s. Connection from the AR panel to the LCS is via RS485 communications protocol. Subsequent LCS’s are connected in a ‘daisy chain’ wiring configuration. Material Finish Dimension Weight Operating Voltage Quiescent Current Monitored Inputs Manual Release Stage 1 & 2 System Inoperative Gas Fired Comms Output 1.2mm steel for Back Box Oyster matt ripple 233H x 186W x 47D mm 860 grams 27VDC 40.5mA Pressure Switch; Low Pressure Switch; Interlock 2A @ 27VDC (Current Limited) Switched 1A @ 27VDC 1A @ 27VDC 1A @ 27VDC RS485 Local Control Station NZ / PAGE 38 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 4310-0019 PRINT EXIT EMERGENCY WARNING SYSTEMS Emergency Warning Systems The Ampac EV3000 Emergency Warning and Intercom System is designed for the purpose of enabling the orderly evacuation of occupants, from a building or structure, in the event of an emergency. The system comprises of two (2) sub-systems. The first being the Emergency Warning System (EWS) and the other the Emergency Intercom System (EIS). While the Warning and Intercom System have separate controls, they coexist in a panel that is logically presented and aesthetically pleasing. The Emergency Warning System makes use of speakers strategically placed around the site, to broadcast ALERT, and/or EVACUATION signals or public address announcements. The EWS may be automatically initiated or manually operated. When not used in an emergency situation, the EV3000 can broadcast background music and/or general paging announcements. The Emergency Intercom System (EIS) consists of front panel control at the Emergency Control Panel (ECP) and Warden Intercom Phones (WIP) that are strategically placed throughout the building. Communication is only possible between the WIP and ECP. For larger sites, multiple control panels may be networked. NZ / PAGE 39 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT EMERGENCY WARNING SYSTEMS Emergency Warning Systems •Modular system design – can be easily customised to meet special requirements •Discrete front panel control – ‘natural’ style layout easy to locate zones •Amplifiers available: 40, 120, 240 & 480-watts – choice of amplifiers to suit your need •Visual output for hearing impaired or noisy environments •Common or individual fire alarm inputs – an “all call” or staged evacuation may be configured •2-wire Warden Intercom Phones (WIP) – monitored for open and short circuit •Common or zoned background music inputs – non-emergency input gives EV3000 the flexibility to fit most applications including shopping centres, hospitals, etc •Monitoring of speaker circuits – monitoring for short or open circuit •Monitoring of Visual Warning indicators – monitoring for short or open circuit •Automatic volume control incorporating ambient noise sensing microphone – ideal for applications where the ambient noise levels are different at various times of day •Fail safe volume override output – used as a control to shutdown all non-emergency facilities offered by the EV3000 and to override attenuated volume controls located in the field •Stand-by signal generators – provides 100% backup of emergency tones for greater reliability •Stand-by microphone amplifiers – provides 100% backup of emergency public address for greater reliability •Automatic changeover to stand-by amplifier – may be configured in the event an active amplifier is faulty •Digital paging console – attractive remote paging console with seven (7) segment digital display and keypad gives operator quick and easy access to paging zones •Networked system – expands EV3000 features to include master / sub panel configuration, and remote paging console •Optic Fibre Interface – the optional Optic Fibre interface allows the EV3000 to be networked over optic fibre cables NZ / PAGE 40 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel Mechanical Material Finish Dimensions Approvals Signals EV3000 12U NZ / PAGE 41 Electrical Power Supply 7.5, 13, 19.5 or 26 Amps @ 24 VDC RS485 @ 9600 bps Communication EWS Zones 144 max EIS Zones 288 max 8 max (recommended) Paging Console 12 max (recommended) ECP’s Visual Warning Option 1EV3000 Visual Outputs Maximum of 8 pairs per visual circuit (for Xenon 208-0011) Option 2EV3000 Visual Outputs Maximum of 40 pairs per visual circuit (for LED 208-0063) Note: The LED visual pairs require the Ampac 4210-0031 Visual Driver Kit fitted EV3000 16U EV3000 29U EV3000 29U Double Rack CONTACT AMPAC 1.6mm Mild Steel Powder Coated Arch White 10U 700H x 625W x 240D mm (SEC P only) 12U 900H x 650W x 290D mm 16U 1200H x 700W x 375D mm 29U 1800H x 700W x 375D mm SSL – AS2220.89 Compliant with AS1670.4:2004 HOME EV3000 Emergency Control Panel 12U MECP 16U MECP 29U MECP 29U Double Cabinet MECP 10U SECP 12U SECP 16U SECP 29U SECP CONTENTS SEARCH 105-0001 105-0002 105-0003 105-0007 105-0004 105-0005 105-0006 105-0009 ZOOM PRINT EXIT EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel – Add Ons 40 Watt Power Amplifier • A modular power amplifier that is rated at 40 watts •Multi-channel audio input supports Alert tone, Evacuation tone, Public Address, and background music • Continuous monitoring of amplifier and 100 volt speaker circuit • Overload protection with Automatic • Easily plugs into an Ampac EV3000 amplifier frame • Can fit up to 8 amplifiers per frame Voltage 24 VDC 58mA Quiescent current Max current 3400mA Max output power 40 Watts Output voltage 100 VAC RMS Freq. Response 150Hz to 12kHz (±1dB) Max 1% at full load Distortion (typical 0.5%) Sensitivity +5dB <200Kohm balanced) (1.4VRMS) Overload 100 VRMS + 10% 675 grams Weight 40 Watt Power Amplifier 154-0075 120 Watt Power Amplifier •A modular power amplifier that is rated at 120 watts •Multi-channel audio input supports Alert tone, Evacuation tone, Public Address, and background music •Continuous monitoring of amplifier and 100 volt speaker circuit •Overload protection with Automatic •Easily plugs into an Ampac EV3000 amplifier frame •Can fit up to 4 amplifiers per frame Voltage Quiescent current Max current Max output power Output voltage Freq. Response Distortion Signal to Noise Overload Weight 24 VDC 175mA 8100mA 120 Watts 100 VAC RMS 210Hz to 14.5kHz (±1dB) < 0.2% at full load 77 dB 100 VRMS + 10% 1160 grams 120 Watt Power Amplifier NZ / PAGE 42 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 154-0077 PRINT EXIT EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel – Add Ons 240 Watt Power Amplifier •24v DC supply •Mother board address strapping (120 address positions) •Continuous fault monitoring •Volume override output •Test tone input •Data selectable 4 channel input (balanced) •Tone generator synchronisation input •Indication (power on - green, power shutdown - yellow, amp or line fault - red, overload - red) •Minimum cable size 2.5mm² Voltage Quiescent current Max current Max output power Output voltage Freq. Response Distortion Signal to Noise Overload Weight 24 VDC 350mA 16200mA 240 Watts 100 VAC RMS 210Hz to 14.5kHz (±1dB) < 0.2% at full load 77 dB 100 VRMS + 10% 2320 grams 240 Watt Power Amplifier 154-0001 480 Watt Power Amplifier •24v DC supply •Mother board address strapping (120 address positions) •Continuous fault monitoring •Volume override output •Test tone input •Data selectable 4 channel input (balanced) •Tone generator •Indication (power on - green, power shutdown - yellow, amp or line fault - red, overload - red) •Minimum cable size 4mm² Voltage Quiescent current Max current Max output power Output voltage Freq. Response Distortion Signal to Noise Overload Weight 24 VDC 700mA 32400mA 480 Watts 100 VAC RMS 210Hz to 14.5kHz (±1dB) < 0.2% at full load 77 dB 100 VRMS + 10% 4640 grams 480 Watt Power Amplifier NZ / PAGE 43 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 154-0002 PRINT EXIT EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel – Add Ons Emergency Alarm Initiating Device (EAID) • Connects to S004 WIP •2 wires for WIP & EAID •Compatible with 219-0015 Emergency Alarm Initiating Device (EAID) 213-0068 Warden Intercom Phone – 2 Wire (S004) • 2 Wire WIP/EAID wiring •High quality WIP audio •Complies with AS4428.4 •Suitable for models manufactured after July 2010 Operating Voltage Line Voltage Current draw Line Impedance Line Level Cabling Dimensions Weight 27 VDC (line driven) On hook - 25 VDC max Off hook - 14 VDC max On hook - 5 mA max Off hook - 35 mA max 360 ohm balanced 0 dB (± 3dB) 2 wire - 2.5mm² max. 215H x 85W x 62D mm 380 grams Warden Intercom Phone – 2 Wire (S0004) WIP Enclosure Metal Surface Mounted NZ / PAGE 44 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 219-0015 291-0054 EXIT EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel – Add Ons Warden Intercom Phone – 3 Wire •The WIP is installed remote to the ECP •Provides intercommunication between users at the WIP and Emergency Control Panel •This feature is only available when the Emergency Warning Intercom facility has been incorporated in the control panel •Made of high impact red ABS plastic •Compatible with most EV3000 systems manufactured before July 2010 27 VDC (line driven) On hook - 25 VDC max Off hook - 14 VDC max On hook - 5 mA max Off hook - 35 mA max 360 ohm balanced 0 dB (± 3dB) 3 wire - 2.5mm² max. 215H x 85W x 62D mm 380 grams Operating Voltage Line Voltage Current draw Line Impedance Line Level Cabling Dimensions Weight Warden Intercom Phone – 3 Wire WIP Enclosure Metal Surface Mounted 219-0007 291-0054 Remote Paging Console •Provides a point to initiate a non-emergency voice announcement via the EV3000 •Provides a pre-announcement tone •Easy keypad operation to broadcast voice announcements to selected zones, or group of zones •Connects to EV3000 via RS485 •Derives power from the EV3000 panel NZ / PAGE 45 CONTACT AMPAC HOME CONTENTS Size Supply voltage Current Communication Weight 80H x 300W x 220D mm 12 VDC 400 mA RS 485 1160 grams Remote Paging Console SEARCH ZOOM 154-0005 PRINT EXIT EMERGENCY WARNING SYSTEMS EV3000 Emergency Control Panel – Add Ons Fibre Optic Network Interface for EV3000 The fibre modem network interface kit offers the user a method of interconnecting two (2) or more EV3000 Emergency Warning and Intercom System (EWIS) using fibre optic cable as an alternative to copper. The modems convert hardwired data and audio, to a common fibre optic compatible output. The fibre optic modems are full duplex and have 4-channels to carry both data and two (2) audio signals. Two (2) channels are required – emergency public address and warden intercom audio signals. Supply Voltage 12 VDC 300 mA Quiescent Current Input Ports Available RS422 Emergency P.A. Warden Intercom Phone Audio Max. Distance 5 km 2-core multimode fibre Cabling ST Standard Fibre Connector Optical Data Wavelength850nm ModeMultimode LED Emitter type Operating Temperature 0°C to +55°C 0 to 95% relative, Humidity noncondensing Size L104 x W144 x D25 mm Fibre Optic Network Interface for EV3000 154-0074 Combined Strobe for EV3000 (Indoor) Combined Strobe for EV3000 (IP65 Outdoor) 208-0066 208-0065 Combined Strobe for EV3000 (Surface Mount) Item pictured is 208-0066 Indoor. The IP65 model uses the deep base to achieve an outdoor solution where required. NZ / PAGE 46 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT EMERGENCY WARNING SYSTEMS Speakers Horn Speaker – 10 Watt •10 watts power rating RMS •Adjustable wattage taps 10, 5, 2.5, 1.25W and 8 ohm •Frequency response 300 Hz-8 kHz •106 dB sensitivity (1W/1M) •120 degree dispersion •16.2cm diameter, 24.2cm length •1.3kg •Metal and ABS construction Horn Speaker – 10 Watt 218-0002 Horn Speaker – 15 Watt 218-0005 Horn Speaker – 15 Watt •IP66 rated •15W power rating RMS •Frequency response 125 Hz-14000 Hz •Adjustable wattage taps 15, 7.5, 3.75, 1.87W and 8 •108 dB sensitivity (1W/1M) • 110 degree dispersion •3.2kg •Metal and ABS construction •Includes capacitor for EVAC purposes NZ / PAGE 47 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT EMERGENCY WARNING SYSTEMS Speakers Ceiling Speaker – 100mm Recessed •100 mm recessed ceiling speaker •Operates with 100 volt speaker line •Capacitor fitted for line monitoring •Five (5) power output settings •Safety cover to protect terminals •Facility to secure field cabling to speaker housing •Optional low profile grill available Rated Power Line Voltage Frequency R esponse SPL Speaker Tap (watt) Cut-out size Dimensions Weight 5 watts 100 Volt 100 Hz to 20 kHz 96 dB (1 watt @ 0.5m) 0.33, 0.66, 1.25, 2.5, 5 85 mm Diameter 100 x 105 Hmm 800 grams Ceiling Speaker – 100mm Recessed Low Profile Grill 218-0008 218-0012 Ceiling Speaker – 200mm Recessed •200 mm recessed ceiling speaker •Operates with 100 volt speaker line •Capacitor fitted for line monitoring •Five (5) power output settings •Safety cover to protect terminals •Facility to secure field cabling to speaker housing •Optional low profile grill available Rated Power Line Voltage Frequency R esponse SPL Speaker Tap (watt) Cut-out size Dimensions Weight 5 watts 100 Volt 100 Hz to 20 kHz 96 dB (1 watt @ 0.5m) 0.33, 0.66, 1.25, 2.5, 5 190 mm Diameter 200 x 75 Hmm 1 kg Ceiling Speaker – 200mm Recessed Low Profile Grill NZ / PAGE 48 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 218-0009 218-0011 EXIT EMERGENCY WARNING SYSTEMS Speakers Surface Speaker •Custom designed speaker and transformer assembly engineered to meet Australian Fire Evacuation Standards •High degree of speech intelligibility Driver Power taps SPL 1W @ 1m Frequency response Connection 100mm (4”) dual cone 0.33, 0.66, 1.25, 2.5, 5W 90dB @ 1kHz (+/- 2dB) 100Hz-15kHz 4 way terminal block + 22uF bipolar capacitor Surface Speaker – 100mm Surface Speaker – 80mm NZ / PAGE 49 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 218-0022 218-9999 PRINT EXIT GRAPHICS PACKAGE SmartGraphicsHD A FireFinder FACP compatible product AMPAC’s SmartGraphicsHD System unleashes the full power of FireFinder (fire detection) and the EV3000 (alarm and intercom) by creating a robust and versatile hub for controlling your fire detection, alarm and intercom systems with one fully integrated package. Flexible and intuitive in its design, SmartGraphicsHD puts the command of your systems at your fingertips. • Interfaces to the FireFinder fire detection panel and the EV3000 emergency warning and intercom system • Clearly shows on the building floor plan the start and spread of the fire and the status of the emergency warning and intercom system • Has capabilities of e-mailing maps to emergency service organisations and key stakeholders • Supports the latest 1920x1080 HD computer technology • Able to operate over existing IT infrastructure • Can be expanded to incorporate multi-site facilities into one central monitoring package • Historic data log on the activity of the fire detection system and alarm system • Three level password protection • Detailed Egress Pathways • Building Information (like hazardous materials) and mustering point displayed on maps NZ / PAGE 50 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT GRAPHICS PACKAGE Graphics Package Computer (Rec Min) Monitor RS232 Comms RS485 Comms Ethernet Intel Core Processor 2Ghz, 2GB RAM, 500 GB Hard Drive, CDROM, 6 USB Ports Serial Comms port for connection to FACP (RS232 or RS485 as required) Windows XP Professional (32bit) , or Windows 7 Professionl (32bit) 20” min (resolution 1920 x 1080) 1 pair twisted & screened 15m maximum from FireFinder Baud rate- 9600 to 38400 1 pair twisted & screened 1200m maximum from FireFinder 8 pin RGRJ45 Connector 10/100 Mbps IEEE 802.3. IEEE 802.38 SmartGraphicsHD Licence Package Only 4100-0002 Licence Package and computer - including a colour laser printer 4100-0003 4100-0004 Licence Package and embedded computer with touch screen - including a colour laser printer Licence Package and computer with touch screen monitor 4100-0005 - including a colour laser printer Ethernet159-0613 * Graphical Engineering available- please contact your local CSO Office. NZ / PAGE 51 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS Series 65 Conventional Detectors Series 65 incorporates well-proven sensing technologies together with advances in materials and electronics. Developed from the highly successful Series 60 range of detectors, Series 65 includes a chip (integrated circuit) based on that used in XP95 analogue addressable detectors. The range consists of ionisation, integrating ionisation and optical smoke detectors, four grades of heat detector and a range of bases. • Wide operating voltage • Advanced electronic technology • Flashing LED option • Magnetic test switch option • Can be used on security systems • Electrically and mechanically compatible with Series 60 • Proven detection performance NZ / PAGE 52 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS SERIES 65 Conventional Series 65 Ionisation Smoke Detector The Series 65 Ionisation Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm. • • • • Responds well to fast-burning, flaming fires Designed to operate in a variety of environments Wide operating voltage Flashing LED and magnet operated test switch option Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base 9-33 VDC 20-45μA at 24 VDC 52mA at 24 VDC 100Dia x 50H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) IP23D (EN60529) 153 grams Series 65 Ionisation Smoke Detector 55000-217APO Approvals: EN54-7/LPCB Series 65 Integrating Ionisation Smoke Detector Ionisation Detectors use a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm. Circuitry in the Ionisation Smoke Detector protects against transient levels of smoke above the normal threshold for up to 20 seconds. • • • • Responds well to fast-burning, flaming fires Designed to operate in environments where transient levels of smoke may be expected Wide operating voltage Flashing LED and magnet operated test switch option Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base 9-33 VDC 20-45μA at 24 VDC 52mA at 24 VDC 100Dia x 50H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) IP23D (EN60529) 153 grams Series 65 Integrating Ionisation Smoke Detector 55000-220APO Approvals: EN54-7/LPCB NZ / PAGE 53 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS SERIES 65 Conventional Series 65 Optical Smoke Detector The Series 65 Optical Smoke Detector incorporates a pulsing LED located within the housing of the detector. The external detector moulding is identical to that of the ionisation detector but has an indicator LED which is clear in quiescent state but produces red light in alarm. • • • • • Responds well to slow-burning, smouldering fires Well suited for bedrooms and escape routes Unaffected by wind or atmospheric pressure Wide operating voltage Flashing LED and magnet operated test switch option Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base Sensitivity 9-33 VDC 30-50μA at 24 VDC 52mA at 24 VDC 100Dia x 50H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) IP23D (EN60529) 150 grams 0.15dB/m obscuration Series 65 Optical Smoke Detector 55000-317AMP Approvals: EN54-7/LPCB Series 65 Heat Detector The Series 65 Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are four classes of heat detectors in the Series 65 range designed to suit a wide variety of operating conditions. • • • • Can be used for applications where smoke detectors are unsuitable Ideal in environments that are dirty or smokey under normal conditions Wide operating voltage Flashing LED and magnet operated test switch option CONTACT AMPAC 9-33 VDC 45μA at 24 VDC 52mA at 24 VDC 100Dia x 50H mm -20°C to +90°C (no icing) 0 to 95% (non condensing) IP23D (EN60529) 131 grams Series 65 A1R (5O°C) Heat Detector- Rate of Rise Series 65 BR (65°C) Heat Detector- Rate of Rise Series 65 CR (80°C) Heat Detector- Rate of Rise Series 65 CS (80°C) Heat Detector- Static Approvals: EN54-5/LPCB NZ / PAGE 54 Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base HOME CONTENTS SEARCH ZOOM PRINT EXIT 55000-122APO 55000-127APO 55000-132APO 55000-137APO DETECTORS SERIES 65 Conventional Series 65 Standard Base The Series 65 Standard Base has been designed to enable detectors to be fitted without the need for force – particularly useful when fitting to suspended ceilings. All Series 65 bases have a one way fit and can be locked into place by a grub screw using a 1.5mm hexagonal screwdriver. • • • • • Size Weight 100Dia x 8H mm 51 grams Standard Base 45681-200AMP Detector locking mechanism One way fit Easy to wire Contains an earth connector Contains no electrical parts Approvals: EN54-5, 7 & 8/LPCB Series 65 Standard Relay Base The Series 65 Standard Relay Base provides one set of free, changeover (form C) contacts that change state when the detector signals an alarm. • • • • Detector locking mechanism One way fit Easy to wire Contains an earth connector Size Weight 100Dia x 8H mm 51 grams Series 65 Standard Relay Base 45681-245APO Approvals: EN54-5, 7 & 8/LPCB NZ / PAGE 55 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS Orbis Conventional Detectors Orbis is a range of conventional detectors which has been developed with sophisticated technology previously only found in intelligent detectors. Orbis is a range with modern styling and incorporates a mounting base wihich saves installation time. • Automatic drift compensation with DirtAlert® warning • Patented FasTest® which reduces the time taken to test detectors • SensAlert® uses a flashing LED to indicate that the sensor is not operating correctly • StartUp™ for fast commissioning • Attractive and compact design • Electrically compatible with Series 60 and Series 65 • Wide voltage and operating temperature ranges • Algorithms for transient rejection • Flashing LED option • 360° visibility of LEDs • Insect resistant NZ / PAGE 56 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS ORBIS Conventional Orbis Optical Smoke Detector The Orbis Optical Smoke Detector works using the well established light scatter principle, however, the sensing technology is radically different in design from previous optical detectors and significantly reduces false alarms. • • • • • • Responds well to slow-burning, smouldering fires Performs well in black and white smoke Extra confirmation of smoke before alarm signal is given Reduced incidence of false alarms Sensing chamber keeps out dust and other airborne contaminants Operates over a broad range of voltages at extremes of temperature Operating voltage Quiescent current Alarm current Remote output Size Operating temperature Relative humidity IP rating Weight 8.5 to 33 VDC 65μA at 24 VDC 40mA at 24 VDC 1.2kΩ to -ve supply 97Dia x 31H mm -40°C to +70°C (no icing) 0 to 98% (non condensing) IP23D (EN60529) 75 grams Orbis Optical Smoke Detector Orbis Optical Smoke Detector with Flashing LED ORB-OP-12001-AMP ORB-OP-12003-AMP Approvals: EN54-7/LPCB Orbis Multisensor Detector The Orbis Multisensor Detector benefits from the same false alarm reduction technology as the optical detector. It is a thermally enhanced smoke detector and so will not give an alarm from heat alone. • • • • • Responds well to fast-burning, flaming fires Reduced incidence of false alarms Increased reliability of detection Sensing chamber keeps out dust and other airborne contaminants Operates over a broad range of voltages at extremes of temperature CONTACT AMPAC 8.5 to 33 VDC 65μA at 24 VDC 40mA at 24 VDC 1.2kΩ to -ve supply 97Dia x 42H mm -40°C to +70°C (no icing) 0 to 98% (non condensing) IP23D (EN60529) 80 grams Orbis Multisensor Detector ORB-OH-13001-AMP Orbis Multisensor Detector with Flashing LED ORB-OH-13003-AMP Approvals: EN54-7/LPCB NZ / PAGE 57 Operating voltage Quiescent current Alarm current Remote output Size Operating temperature Relative humidity IP rating Weight HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS ORBIS Conventional Orbis Heat Detector The Orbis Heat Detector monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. There are six classes of heat detectors in the Orbis range designed to suit a wide variety of operating conditions. • • • • Can be used for applications where smoke detectors are unsuitable Ideal in environments that are dirty or smoky under normal conditions Reduced incidence of false alarms Increased reliability of detection Operating voltage Quiescent current Alarm current Remote output Size Operating temperature Relative humidity IP rating Weight 8.5 to 33 VDC 65μA at 24 VDC 40mA at 24 VDC 1.2kΩ to -ve supply 97Dia x 36H mm -40°C to +70°C (no icing) 0 to 98% (non condensing) IP23D (EN60529) 70 grams Orbis Heat Detector Orbis A1R (50°C) Heat Detector- Rate of Rise Orbis A2S (50°C) Heat Detector- Static Orbis BR (65°C) Heat Detector- Rate of Rise Orbis BS (65°C) Heat Detector- Static Orbis CR (80°C) Heat Detector- Rate of Rise Orbis CS (80°C) Heat Detector- Static Approvals: EN54-5/LPCB ORB-HT-11001-AMP ORB-HT-11002-AMP ORB-HT-11003-AMP ORB-HT-11004-AMP ORB-HT-11005-AMP ORB-HT-11006-AMP Orbis TimeSaver Base The TimeSaver Base is a completely new design that provides installers with an open working area with fixing holes shaped to allow a simple mounting procedure. • • • • • Grouped terminals to make wiring easy Two fixing centres LED alignment mark Cable stripping guide C ontinuity link for voltage testing of zone wiring prior to commissioning • Detector locking mechanism • O ther devices continue to work during unauthorised removal of detectors 100Dia x 8H mm IP23D (EN60529) 60 grams Size IP rating Weight Orbis TimeSaver Standard Base Orbis TimeSaver LX Base ORB-MB-00001-AMP ORB-MB-00002-AMP Approvals: EN54/LPCB NZ / PAGE 58 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS ORBIS Conventional Orbis LX Base The LX Base has the same design as the standard TimeSaver Base with the addition of a diode. It is used in systems which house active EOL monitoring for head removal. • • • • • Grouped terminals to make wiring easy Two fixing centres LED alignment mark Cable stripping guide Detector locking mechanism 100Dia x 8H mm -40°C to +70°C 0 to 98% IP23D (EN60529) 60 grams Size Operating temperature Humidity IP rating Weight Orbis LX Base ORB-MB-00012-AMP Approvals: EN54/LPCB Orbis TimeSaver Relay Base The TimeSaver Relay Base incorporates a single pole voltage-free changeover contact for switching external equipment. When the detector changes to the alarm state, the relay is energised, causing the contact to change state. The contact will remain in this condition until the detector is reset. • • • • • • • Grouped terminals to make wiring easy Two fixing centres LED alignment mark Cable stripping guide Continuity link for voltage testing of zone wiring prior to commissioning Detector locking mechanism Capable of switching up to 30V at 1A Size Operating temperature Humidity IP rating Weight 100Dia x 8H mm -40°C to +70°C 0 to 98% IP23D (EN60529) 60 grams Orbis TimeSaver Relay Base ORB-RB-10004-APO Approvals: EN54/LPCB NZ / PAGE 59 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS ORBIS Conventional Ampac Duct Sampling Unit The Ampac Duct Sampling Unit is designed to monitor levels of smoke in air ducts operating in air speeds of 0.5 to 20 meters per second. The duct smoke detector can be fitted to any wall of a ventilation duct and has two tubes that extend into the duct through punched holes. The perforated sampling tube is placed in the airflow upstream of the exhaust tube which causes a pressure differential in the duct detector. Air is sucked up the sampling tube, across the detector and exhausted back into the air duct. • T he cover of the duct smoke detector is monitored to ensure working integrity and if removed, causes a fault to appear at the fire alarm control panel • Easily accessible wire clamping terminals ensure secure and fast termination • Clear cover hence the alarm LED on the detector is visible at all times • Unique self-sealing test port allows the dispensing of test smoke via a needle into the duct smoke detector to be tested without the need to remove the cover • Sampling pipes available in 4 lengths • Weather resistant enclosure Approvals: C-tick, AS1603-13 Using the 360mm sampling pipe supplied, an air duct of up to 560mm can be monitored. For duct widths greater than 560mm, three other lengths of sampling pipe are available: 1. For duct width 300 to 750mm 2. For duct width 750 to 1500mm 3. For duct width 1500 to 3000mm Housing Cover Dimension Temperature Range Humidity Weight Grey - ABS Transparent - ABS 115H x 340W x 60D mm 0 to +60°C Up to 85%, no condensation 5.5 kg Orbis Duct Sampling Unit inc Detector Base Duct Probe 300 to 750mm- Sampling Pipe Duct Probe 750 to 1500mm- Sampling Pipe Duct Probe 1500 to 3000mm- Sampling Pipe Orbis Photo Optical Head 53546-023AMP 53541-170APO 53541-171APO 53541-172APO ORB-OP-12001-AMP Note: The detector head is sold separately to the duct sampling unit • V olt free normally opened or closed non-latching relay contact. Relay energises when detector is in alarm (Available only with Ampac Orbis option) oth sampling and exhaust pipes are fitted to the back box without • B the need for tools making installation easier NZ / PAGE 60 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS AMPAC Detectors Ampac AHD-06 Conventional Heat Detector The AHD-06 Indicating Heat Detector is specifically designed to meet the requirements of NZS4512:2003. With an emphasis on quality and reliability, the new heat detector also adopts a look and feel similar to the Orbis range of conventional detectors. • • • • • Self-resetting thermostat element 57°C and 77°C versions Temperature setting clearly marked with a coloured dot Test points for measuring line voltages Non-polarity sensitive Approvals: NZS4512:2003 17 to 28 VDC 0°C to +90°C (no icing) 0 to 95% IP67 70Dia x 37H mm Operating voltage Operating temperature Humidity Sealed version Size Unsealed Detection AHD-06 57°C Heat (Blue) AHD-06 77°C Heat (Yellow) Sealed Detection AHD-06 57°C Heat (Blue) AHD-06 77°C Heat (Yellow) 4255-0301 4255-0311 4255-0302 4255-0312 Ampac AHD-06 Addressable Heat Detector The AHD-06 Indicating Sealed Addressable Heat Detector is specifically designed to meet the requirements of NZS4512:2003. With an emphasis on quality and reliability, the new heat detector also adopts a look and feel similar to the Orbis range of conventional detectors. Adopting the XP95 addressable protocol, this detector is suitable for use in conjunction with FireFinder Fire Alarm Control Panel. An on board DIP switch facilitates detector address setting. • • • • • Self-resetting thermostat element 57°C and 77°C versions Temperature setting clearly marked with a coloured dot Test points for measuring line voltages Non-polarity sensitive Operating voltage 17 to 28 VDC Operating temperature 0°C to +90°C (no icing) Humidity 0 to 95% SealedIP67 Size 70Dia x 37H mm Sealed Detection XP95 AHD-06 Sealed (57°C) Heat Detector (Blue) XP95 AHD-06 Sealed (77°C) Heat Detector (Yellow) 4255-0322 4255-0332 Approvals: NZS4512:2003 NZ / PAGE 61 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS XP95 Intelligent Detectors The XP95 range of intelligent fire detectors is advanced in design, improved in performance and has unique features that benefit the installer and end user. The range features smoke detectors (ionisation and optical), standard and high temperature heat detectors and a multisensor. Beam detectors, flame detectors, manual call points, audio visual signalling devices, interface units and isolators complete the range. XP95 has a ‘central intelligence’ system where all the decisions are made by the control panel. Features • Alarm Flag for fast alarm reporting • Alarm Address for fast location of alarm • XPERT card addressing • Electronics-free base • Easy installation • Elegant design • Insect Resistant NZ / PAGE 62 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS XP95 Intelligent XP95 Ionisation Smoke Detector The XP95 Ionisation Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm. • • • • Responds well to fast-burning, flaming fires Designed to operate in a variety of environments Minimal effects from temperature, humidity, atmospheric pressure Well protected against electromagnetic interference over a wide frequency range Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base 17-28 VDC 280μA at 24 VDC 2.0mA at 24 VDC 100Dia x 50H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) IP23D 161 grams XP95 Ionisation Smoke Detector- EMC XP95 Ionisation Smoke Detector (Black) 55000-520AMP 55000-560APO Approvals: EN54-7/LPCB XP95 Optical Smoke Detector The XP95 Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely. • Responds well to slow-burning, smouldering fires • Well suited for bedrooms and escape routes • Unaffected by wind or atmospheric pressure Approvals: EN54-7/LPCB Voltage 17-28 VDC Quiescent current 340μA at 24 VDC Alarm current 4mA at 24 VDC Size inc base 100Dia x 50H mm -20°C to +60°C (no icing) Operating temperature Relative humidity 0 to 95% (non condensing) IP rating IP23D Weight inc base 157 grams Sensitivity0.12db/m XP95 Optical Smoke Detector- EMC XP95 Optical Smoke Detector (Black) NZ / PAGE 63 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 55000-620AMP 55000-660AMP EXIT DETECTORS XP95 Intelligent XP95 Heat Detector The XP95 Heat Detector monitors temperature by using a single thermistor network which provides a count output proportional to the external air temperature. The XP95 range features two Heat Detectors, standard and high temperature. The standard heat detector is classified as an A2S device and will report an alarm at 55°C. The high temperature detector, classified as a CS device, will report an alarm at 90°C. • Ideal in environments that are dirty or smokey under normal conditions • Well suited for warehouses, loading bays and car parks • Unaffected by wind or atmospheric pressure Approvals: EN54-5/LPCB Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base 17-28 VDC 250-270μA at 24 VDC 2mA at 24 VDC 100Dia x 50H mm A2S: -20°C to +70°C (no icing) CS: -20°C to +120°C (no icing) 0 to 95% (non condensing) IP53 157 grams XP95 Heat Detector Standard – A2S (55°C) - EMC XP95 Heat Detector High Temp– CS (90°C) - EMC 55000-420AMP 55000-401APO XP95 Intelligent Low Power Relay Base The Low Power Relay Base incorporates a low power relay to control field equipment such as automatic door closers. • • • Gives a set of voltage free contacts controlled by the remote output of a detector Draws negligible current Capable of switching up to 30V at 1A Voltage Quiescent current Size Operating temperature Relative humidity Weight 17-28 VDC 5mA at 24 VDC 100Dia x 24H mm -20°C to +70°C (no icing) 0 to 95% (non condensing) 100 grams XP95/Discovery Low Power Relay Base with Xpert Card NZ / PAGE 64 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT 45681-242APO DETECTORS XP95 Intelligent XP95 Intelligent Detector Base All detectors in the XP95 range fit the Intelligent Detector Base. It is a low insertion force base with stainless steel contacts for the detector terminals. • XPERT addressing • One way fit of detector • Locking feature to prevent unauthorised removal Size Operating temperature Relative humidity Weight 100Dia x 8H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) 55 grams XP95/Discovery Detector Base with Xpert Card XP95 Detector Base (Black) with Xpert Card Approvals: EN54-5, 7 & 8/LPCB 45681-210AMP 45681-361APO XP95 Isolating Base The new style Isolating Base senses and detects short-circuit faults on XP95 loops and spurs. • Up to 20 devices may be installed between isolating bases • High brightness LED Voltage Quiescent current Size Operating temperature Relative humidity Weight 17-28 VDC 47μA (non isolating) 4mA (isolating) 100Dia x 24H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) 100 grams XP95/Discovery Isolating Base with Xpert Card NZ / PAGE 65 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 45681-284APO EXIT DETECTORS XP95 Intelligent Blank XPERT Card Pre-addressed XPERT Card A universal address card supplied with all bases. Using a coding guide, pips are removed to set the address of the inserted detector. Pre-addressed XPERT cards are supplied with pips already removed. • • • • Simplifies and speeds up installation and commissioning Uses patented, proven technology Address remains the same, no matter how often detectors are replaced Flexibility to create any address z Saves time and increases accuracy during commissioning z Pre-numbered 1-126 XP95/Discovery Xpert Card (Blank) Pre-addressed (1-126) Xpert Cards 38531-771 45682-127 XP95 Intelligent Reflective Beam Detector The XP95 Reflective Beam Detector differs from a traditional beam detector in that it is a single unit which houses a transmitter, a receiver and the control electronics. The beam detector is available in two versions: a single reflector model for distances of 5-50m and a four-reflector unit for distances of 50-100m. • • • • • NZ / PAGE 66 Loop-powered, requires no external supply Compatible with Discovery and XP95 protocols Incorporates a short-circuit isolator Automatic drift compensation Automatic reset following alarm or fault condition CONTACT AMPAC HOME Input voltage Quiescent current Alarm current Dimensions Operating temperature Relative humidity IP rating Weight Min beam distance Max beam distance 17-28 VDC 5μA @ 24 VDC 9mA at 24 VDC 210H x 150W x 120D mm -20°C to +55 °C (no icing) 0-95% (non condensing) IP50 670 grams 5 metres 100 metres Reflective Beam (5-50M) Detector XP95 Reflective Beam (50-100M) Detector XP95 Beam Detector Reflector 100mm x 100mm CONTENTS SEARCH ZOOM PRINT 55000-268APO 55000-273APO 29600-201 EXIT DETECTORS XP95 Intelligent Ampac Duct Sampling Unit The Ampac Duct Sampling Unit is designed to monitor levels of smoke in air ducts operating in air speeds of 0.5 to 20 meters per second. The duct smoke detector can be fitted to any wall of a ventilation duct and has two tubes that extend into the duct through punched holes. The perforated sampling tube is placed in the airflow upstream of the exhaust tube which causes a pressure differential in the duct detector. Air is sucked up the sampling tube, across the detector and exhausted back into the air duct. • E asily accessible wire clamping terminals ensure secure and fast termination • Clear cover hence the alarm LED on the detector is visible at all times • Unique self-sealing test port allows the dispensing of test smoke via a needle into the duct smoke detector to be tested without the need to remove the cover • Sampling pipes available in 4 lengths • Weather resistant enclosure Approvals: C-tick, AS1603-13 Housing Cover Dimension Temperature Range Humidity Weight Using the 360mm sampling pipe supplied, an air duct of up to 560mm can be monitored. For duct widths greater than 560mm, three other lengths of sampling pipe are available: Grey - ABS Transparent - ABS 115H x 340W x 60D mm 0 to +60°C Up to 85%, no condensation 5.5 kg Duct Sampling Unit inc XP95 Detector Base Duct Probe 300 to 750mm- Sampling Pipe Duct Probe 750 to 1500mm- Sampling Pipe Duct Probe 1500 to 3000mm- Sampling Pipe XP95 Optical Smoke Detector-EMC 53546-022AMP 53541-170APO 53541-171APO 53541-172APO 55000-620AMP Note: The detector head is sold separately to the duct sampling unit 1. For duct width 300 to 750mm 2. For duct width 750 to 1500mm 3. For duct width 1500 to 3000mm • B oth sampling and exhaust pipes are fitted to the back box without the need for tools making installation easier • T he cover of the duct smoke detector is monitored to ensure working integrity and if removed, causes a fault to appear at the fire alarm control panel NZ / PAGE 67 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS Discovery Intelligent Detectors Discovery is a range of high-specification, intelligent fire detectors developed to meet the requirements of sophisticated systems while providing engineers with an additional dimension in fire protection capability. Discovery has a ‘distributed intelligence system’ where decisions are made in the detector head as well as at the control panel. Drift compensation is also incorporated into the detector, allowing it to adapt to dirty or dusty environments, reducing false alarms. • Rejection of transient signals • Flashing LED option • Five response modes for ease of optimisation to changing environments • Drift compensation to ensure constant sensitivity • Four bytes of non-volatile memory for user data • Alarm flag for fast alarm reporting • Conventional alarm facility during control panel processor fault • 360° visibility in alarm • Compatible with XP95 systems • Insect resistant NZ / PAGE 68 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS APOLLO DISCOVERY Intelligent Discovery Ionisation Smoke Detector The Discovery Ionisation Smoke Detector uses a low activity radioactive foil to irradiate the air in the smoke chamber causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm. • Responds well to fast-burning, flaming fires • Designed to operate in a variety of environments • Remote test feature Approvals: EN54-7/LPCB Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base 17-28 VDC 500μA at 24 VDC 3.5mA at 24 VDC 100Dia x 50H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) IP43 160 grams Discovery Ionisation Smoke Detector 58000-500AMP Discovery Optical Smoke Detector The Discovery Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely. • • • • Responds well to slow-burning, smouldering fires Well suited for bedrooms and escape routes Unaffected by wind or atmospheric pressure Remote test feature Approvals: EN54-7/LPCB NZ / PAGE 69 CONTACT AMPAC Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base 17-28 VDC 400μA at 24 VDC 3.5mA at 24 VDC 100Dia x 50H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) IP43 160 grams Discovery Optical Smoke Detector HOME CONTENTS SEARCH ZOOM 58000-600AMP PRINT EXIT DETECTORS APOLLO DISCOVERY Intelligent Discovery Heat Detector The Discovery Heat Detector, distinguishable by the low airflow resistant case, uses a single thermistor to sense the air temperature around the detector. • • • • Ideal in environments that are dirty or smokey under normal conditions Well suited for warehouses, loading bays and car parks Unaffected by wind or atmospheric pressure Remote test feature Approvals: EN54-5/LPCB Heat Detector Response Modes Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base 17-28 VDC 500μA at 24 VDC 3.4mA at 24 VDC 100Dia x 50H mm 0°C to +80°C (no icing) 0 to 95% (non condensing) IP53 160 grams Discovery Heat Detector Mode 58000-400AMP ClassApplication (EN54-5:2000)Temperature °C 1 A1R 2 A2 3 A2S 4 CR 5 CS Typ Max 2550 2550 2550 5580 5580 Static Response Temperature °C Min 54 54 54 84 84 Typ 57 61 61 90 90 For air temperatures in the range 15°C to 55°C, the analogue value for a detector in mode 1 will correspond approximately to the air temperature. NZ / PAGE 70 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT Max 65 70 70 100 100 DETECTORS APOLLO DISCOVERY Intelligent Discovery Multisensor Detector The Discovery Multisensor Detector comprises optical smoke and thermistor temperature sensors whose respective outputs can be split to deliver specific smoke or thermal actions respectively. This capability can aid early Alarm warning routines and other advanced detection techniques. • • • • • • • Ideal for a wide range of applications Highly immune to false alarms Well suited for environments such as hotel bedrooms Unaffected by wind or atmospheric pressure Well suited for sensitive environments Heat only, optical only options Remote test feature Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base 17-28 VDC 500μA at 24 VDC 3.5mA at 24 VDC 100Dia x 58H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) IP43 160 grams Discovery Multisensor Detector 58000-700AMP Approvals: EN54-5/LPCB EN54-7/LPCB Multisensor Detector Operating Modes NZ / PAGE 71 CONTACT AMPAC Mode Smoke Sensitivity (grey smoke) 1 2 3 4 5 HOME % per m % per ft 1.1 0.35 2.1 0.7 2.80.9 4.21.4 No response to smoke CONTENTS Temperature Sensitivity Response Type (relative) High No response to heat Low High See text SEARCH Minimum Time to Alarm (seconds) Multisensor Optical Multisensor Multisensor Heat A1 ZOOM PRINT 20 30 20 20 30 EXIT DETECTORS APOLLO DISCOVERY Intelligent Discovery Carbon Monoxide Detector The Discovery Carbon Monoxide (CO) Detector is good at detecting deepseated fires. Please note that CO detectors do not detect smoke particles or heat and are not universal replacements for smoke detectors. • • • • • Enhanced detection capability Early response to hot fires Ideal for smouldering fires Less susceptible to false alarms caused by steam than smoke alarms Five response modes Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base Cell life (max) 17-28 VDC 500μA at 24 VDC 3.5mA at 24 VDC 100Dia x 50H mm 0°C to +50°C (no icing) 15 to 95% (non condensing) IP43 160 grams 7 years Discovery Carbon Monoxide Detector Mode Relative Performance of Detectors in Test Fires NZ / PAGE 72 CONTACT AMPAC Alarm Threshold (ppm) Minimum Time to Alarm (seconds) 30 60 1 58000-300APO Typical Application Sleeping with no ambient CO 2 45 30 General use fast response such as supplementary protection in atria 3 45 60 General use and sleeping risk with some low-level CO (such as from light smoking or an unventilated gas fire) 4 60 30 General smoking area and supplementary detection of deep seated fires such as laundry rooms Supplementary use in kitchen or boiler room 5 75 HOME 30 CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS APOLLO DISCOVERY Intelligent Discovery Intelligent Detector Base All detectors in the Discovery range fit the Intelligent Detector Base. It is a low insertion force base with stainless steel contacts for the detector terminals. XPERT cards are supplied with all bases. • XPERT addressing • One way fit • Locking feature to prevent unauthorised removal Size Operating temperature Relative humidity Weight 100Dia x 8H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) 55 grams XP95/Discovery Detector Base with Xpert Card 45681-210AMP Approvals: EN54-5/LPCB EN54-7/LPCB EN54-8/LPCB Discovery Isolating Base The new style Isolating Base senses and detects short-circuit faults on loops and spurs. • Up to 20 devices may be installed between isolating bases • High brightness LED Voltage Quiescent current Size Operating temperature Relative humidity Weight 17-28 VDC 47μA (non isolating) 4mA (isolating) 100Dia x 24H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) 100 grams XP95/Discovery Isolating Base with Xpert Card NZ / PAGE 73 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 45681-284APO EXIT DETECTORS APOLLO DISCOVERY Intelligent Discovery Intelligent Low Power Relay Base The Intelligent Low Power Relay Base incorporates a low power relay to control field equipment such as automatic door closers. • • • 17-28 VDC 5mA at 24 VDC 100Dia x 24H mm -20°C to +70°C (no icing) 0 to 95% (non condensing) 100 grams XP95/Discovery Low Power Relay Base with Xpert Card 45681-242APO Blank Xpert Card Pre-addressed Xpert Card A universal address card supplied with all bases. Using a coding guide, pips are removed to set the address of the inserted detector. Pre-addressed XPERT cards are supplied with PIPs already removed. • • • • NZ / PAGE 74 Gives a set of voltage free contacts controlled by the remote output of a detector Draws negligible current Capable of switching up to 30V at 1A Voltage Quiescent current Size Operating temperature Relative humidity Weight Simplifies and speeds up installation and commissioning Uses patented, proven technology Address remains the same, no matter how often detectors are replaced Flexibility to create any address CONTACT AMPAC HOME CONTENTS z Saves time and increases accuracy during commissioning z Pre-numbered 1-126 XP95/Discovery Xpert Card Pre-addressed (1-126) Xpert Cards SEARCH ZOOM 38531-771 45682-127APO PRINT EXIT DETECTORS BEAM DETECTORS Conventional FIRERAY 2000 Optical Beam Smoke Detector The FIRERAY 2000 is a conventional infrared optical beam smoke detector. It is an End to End type beam detector and is thus less susceptible to stray reflections since any reflection goes back towards the transmitter. As a result projected Optical Beams can operate within narrower gaps than reflective types. • • • • • • • Separate transmitter and receiver Range 10 to 100 metres Low current consumption Automatic drift compemsation 3 x selectable sensitivity threshold levels Low level control unit Optional electronic alignment tool Operating range 10-100 metres Operating voltage 10.2VDC to 30VDC Fire relay contactsNorm open volt free 2A @ 30VDC Resistive Fault relay contactsNorm closed volt free 2A @ 30VDC Resistive ConditionAlarm condition: fire relay closing May be latching or non-latching Operating temperature -20°C to +55°C (no icing) Relative humidity 0-90% (non condensing) IP rating IP50 FIRERAY 2000 Beam Detector 220-0004 Approvals: AS1603-7, EN54-12 and UL268 FIRERAY 50/100R Optical Beam Smoke Detector The FIRERAY 50R/100R series of reflective infrared optical beam smoke detectors is comprised of a single unit incorporating an infrared transmitter and receiver, with a reflective prism. The infrared signal is reflected by the prism back to the Receiver for analysis, by the detector, of smoke presence. The detector has three ‘Alarm Threshold’ settings which can be selected to suit the environment. • • • • Two models available: 50R 5-50m and 100R 50-100m 12-24VDC operation Three selectable sensitivity threshold levels Robust construction Operating range Operating voltage Operating temperature Relative humidity IP rating 50R: 5-50 metres 100R: 50-100 metres 10.2VDC to 30VDC -20°C to +55°C (no icing) 0-93% (non condensing) IP50 FIRERAY 50R Beam Detector FIRERAY 100R Beam Detector 220-0005 220-0006 Approvals: EN54-12 and UL268 NZ / PAGE 75 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS BEAM DETECTORS Conventional FIRERAY 5000 Motorised Beam System The FIRERAY 5000 Optical Beam Smoke Detectors can be used to provide ‘wide area’ smoke detection. They are usually used in situations where it is impractical, inappropriate or not cost effective (installation, wiring and maintenance) to use traditional point-type detectors. It also enables coverage of a large area, at minimal cost. Optical beam smoke detectors are also ideally suited for situations that might include high ceilings, dusty and dirty environments, or environments that experience temperature extremes. • • • • • • • Up to 4 optical beam detectors per system controller Easy fit system Ground level control Laser assisted alignment Auto-optimise beam alignment Contamination compensation Building shift compensation Operating distance (separation) Cable length – system controller to detector (2 core screened fire resistant) Operating voltage (to system controller) Operating temperature Relative humidity IP rating 8-100 metres 100 metres 14VDC to 28VDC -10°C to +55°C (no icing) 93% (non condensing) IP54 FIRERAY 5000 Motorised Beam System System Controller, Detector and Reflector Additional Detector and Reflector 220-0008 220-0009 Approvals: AS7240-12, EN54-12 and UL268 Accessories for FIRERAY 50R/100R AWD 5000 An extensive range of accessories are available to compliment the FIRERAY product. Accessories for FIRERAY 50R/ 100R AWD 5000 Single Reflector <50m 3 x Reflector Long Range 100m Kit Universal Bracket 1 Prism Plate 4 Prism Plate Universal Ceiling Mount NZ / PAGE 76 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 220-0007 220-0010 220-0011 220-0012 220-0013 220-0014 EXIT INTERFACES Ampac/XP95/Discovery Intelligent Interfaces Apollo and Ampac manufacture a comprehensive range of interfaces for intelligent systems which enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. There are a variety of interfaces available to suit a number of individual applications. Standard Interfaces with Isolators are fitted with bi-directional short-circuit isolators so that they are unaffected by a single short circuit on either loop input or output. However, the Input/Output Unit and Output Unit with isolator are exceptions to this. The removal of loop power to these interfaces will cause a ‘set’ relay to ‘reset’. DIN-Rail Interfaces feature enclosures that clip to standard 35mm DIN-Rails or are screwed to the base of a larger enclosure. They enable fire system designers to determine the functions required and create multi-purpose interfaces for individual sites. • Easy to install • Well protected • Modular design • A neat solution NZ / PAGE 77 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT INTERFACES AMPAC INPUT/OUTPUT DEVICES Intelligent Single Input Device (SID) The Single Input Device is an addressable loop device for use on the Apollo XP95 or Discovery protocol and provides a single monitored input. •Interfaces a switch input to an Apollo addressable loop • Loop powered • One monitored input • Only one address used • Enclosure or DIN-Rail chassis mount • Status indicators can be switched on and off Voltage Quiescent current Max current Monitored input Size – enclosure Size – DIN chassis Operating temperature Humidity IP rating – enclosure Weight – enclosure Weight – DIN chassis 17-28 VDC 1.82mA at 24 VDC 2.37mA at 24 VDC 20k normal 500 - 15k closed 132H x 82W x 55D mm 77H x 57W x 40D mm -20°C to +60°C (no icing) 0 to 95% relative humidity IP55 155 grams 75 grams Single Input Device (SID) – Boxed Single Input Device (SID) – DIN mount 201-0300 201-0350 Single Input/Output Device (SIOD) The Single Input/Output Device is an addressable loop device for use on the Apollo XP95 or Discovery protocol and provides a single monitored input and a voltage free relay output. •Interfaces a switch input and a relay output to addressable loop • Loop powered • One monitored input • Single relay with clean changeover contact • Only one address used • Enclosure or DIN-Rail chassis mount • Status indicators can be switched on and off Voltage Quiescent current Max current Relay contact rating Monitored input Size – enclosure Size – DIN chassis Operating temperature Humidity IP rating – enclosure Weight – enclosure Weight – DIN chassis 17-28 VDC 1.74mA at 24 VDC 6.84mA at 24 VDC 1A at 24 VDC clean changeover 20k normal 500 - 15k closed 132H x 82W x 55D mm 77H x 57W x 40D mm -20°C to +60°C (no icing) 0 to 95% relative humidity IP55 155 grams 75 grams Single Input/Output Device (SIOD) – Boxed Single Input/Output Device (SIOD) – DIN mount NZ / PAGE 78 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 201-0301 201-0351 EXIT INTERFACES AMPAC INPUT/OUTPUT DEVICES Intelligent Three Input Device (3ID) The Three Input Device is a versatile loop-powered three monitored input unit device for use on the Apollo XP95 or Discovery protocol. •Interfaces three switch inputs to addressable loop • Loop powered • Three monitored inputs • Only one address used • Enclosure or DIN-Rail chassis mount • Status indicators can be switched on and off Voltage Quiescent current Max current Monitored input Size – enclosure Size – DIN chassis Operating temperature Humidity IP rating – enclosure Weight – enclosure Weight – DIN chassis 17-28 VDC 1.45mA at 24 VDC 3.54mA at 24 VDC 20k normal 500 - 15k closed 200H x 150W x 60D mm 98H x 72W x 40D mm -20°C to +60°C (no icing) 0 to 95% relative humidity IP41 500 grams 125 grams Three Input Device (3ID) – Boxed Three Input Device (3ID) – DIN mount 201-0308 201-0358 Three Input/Output Device (3IOD) The Three Input/Output Device is a versatile loop-powered unit for use on the Apollo XP95 or Discovery protocol. It provides three monitored inputs and three voltage free relay outputs. •Interfaces three switch inputs and three relay outputs to addressable loop • Loop powered • Three fault monitored input • Three relays with clean changeover contact • Only one address used • Enclosure or DIN-Rail chassis mount • Status indicators can be switched on and off Voltage Quiescent current Max current Relay contact rating Monitored input Size – enclosure Size – DIN chassis Operating temperature Humidity IP rating – enclosure Weight – enclosure Weight – DIN chassis 17-28 VDC 2.06mA at 24 VDC 19.23mA at 24 VDC 1A at 24 VDC clean changeover 20k normal 500 - 15k closed 200H x 150W x 60D mm 98H x 72W x 40D mm -20°C to +60°C (no icing) 0 to 95% relative humidity IP41 500 grams 125 grams Three Input/Output Device (3IOD) – Boxed Three Input/Output Device (3IOD) – DIN mount NZ / PAGE 79 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 201-0309 201-0359 EXIT INTERFACES AMPAC INPUT/OUTPUT DEVICES Intelligent Three Input/Output Device (3IOD) – Externally Powered The Three Input/Output Device EP is an externally powered unit device for use on the Apollo XP95 or Discovery protocol. Using an external 24VDC power supply, each device draws a minimum amount of loop current and provides three monitored inputs and three voltage free relay outputs. •Interfaces three switch inputs and three relay outputs to addressable loop • Externally powered • Three fault monitored input • Three relays with clean changeover contact • Only one address used • Enclosure or DIN-Rail chassis mount • Status indicators can be switched on or off Voltage Quiescent current – loop Quiescent current – external Max current – loop Max current – external Relay contact rating Monitored input Size – enclosure Size – DIN chassis Operating temperature Humidity IP rating – enclosure Weight – enclosure Weight – DIN chassis 17-28 VDC 1.51mA at 24 VDC 5.08mA at 24 VDC 7.20mA at 24 VDC 19.55mA at 24 VDC 1A at 24 VDC clean changeover 20k normal 500 - 15k closed 200H x 150W x 60D mm 98H x 72W x 40D mm -20°C to +60°C (no icing) 0 to 95% relative humidity IP41 500 grams 125 grams Three Input/Output Device (3IOD) EP – Boxed Three Input/Output Device (3IOD) EP – DIN mount 201-0310 201-0360 Loop Powered Zone Interface Device (LZID) Ampac’s Loop Powered Zone Interface Device (LZID) is designed to connect to the analogue loops in any of Ampac’s addressable range of fire alarm control panels (FACP’s). The LZID supports the Apollo XP95 & Discovery protocol and provides a single conventional zone input and a remote LED output to indicate an Alarm. •Single conventional zone input • Apollo XP95 and Discovery protocol • Supports up to 40 conventional detectors • Remote LED output • Short circuit isolation • Enclosure or DIN-Rail chassis mount • Programmable EOL (3K3Ω, 6K2Ω or 10uF) NZ / PAGE 80 CONTACT AMPAC HOME Operating voltage End Of Line Values No. LZIDs/Loop No. Detectors/Zone Operating temperature 16-27 VDC 3K3Ω, 6K2Ω or 10uF 12 x 250mA Loop 24 x 500mA Loop 40 max -0°C to +70°C (no icing) Loop Powered ZID DIN Mount Loop Powered ZID Enclosed CONTENTS SEARCH ZOOM 4210-0004 4210-0005 PRINT EXIT INTERFACES AMPAC INPUT/OUTPUT DEVICES Intelligent Zone Interface Device (ZID) – Externally Powered The Zone Interface Device (ZID) is an addressable device, that must be connected to an Apollo loop and operate in conjunction with an Ampac FireFinder . The ZID is capable of providing the user with a single monitored input, typically for conventional detectors. • M aximum of 12 detectors per zone when used as a conventional zone device • U sing external power 24 VDC allows a significant number of interfaces to be connected to the loop • Can be used as loop powered or externally powered • See PDS for power feed recommendations NZ / PAGE 81 CONTACT AMPAC HOME CONTENTS Operating Voltage Quiescent Current Alarm Current In-line Resistor End-of-line Resistor IP rating 27 VDC (external power) 9.6 mA 53.2 mA max 1 k Ω (switch only) 4k7 Ω IP 41 Zone Interface Device (ZID) – Externally Powered SEARCH ZOOM PRINT 201-0100 EXIT INTERFACES AMPAC INPUT/OUTPUT DEVICES Intelligent Apartment Module The Apartment Module (AM) is a loop powered addressable device that helps reduce the costly consequences of an unwanted alarm. An occupant is able to silence a local audible warning, activated by a local smoke detector, and allowing a preset time to investigate the cause of the alarm. Local smoke detectors can be connected directly to the AM • (conventional) or connected to the addressable loop (addressable) and assigned to the AM. • • • • • • • • • • • NZ / PAGE 82 L oop Powered Addressable Device B uilt-in short circuit isolation H ush facility C onventional zone input with heat/smoke detector sensing 100V Line Output with EOL monitoring E vent logging of AM sequence at FACP A llows a group of detectors to be assigned to a nominated AM A esthetically pleasing single gang wall plate – vertical or horizontal O n board visual indication for “polling”, Fire and Fault status R emote ‘Hush’ button input terminals available S uitable for use on the FireFinder and LoopSense Fire Alarm Control Panels CONTACT AMPAC HOME CONTENTS Operating Voltage 21 to 28 VDC (loop powered) 4.9mA with 6k2Ω EOL Quiescent Current 1.9mA with 10μF EOL Alarm Current 4.2mA + Zone alarm current of 14.5mA Zone Circuit 10 detectors (max) with 6k2Ω EOL (detector current < 1.2mA) 20 detectors (max) with 10μF EOL (detector current < 2.4mA) Zone EOL 6k2Ω, 10μF Speaker Circuit 100Volt line, 6 W max, 47k EOL 1 to 126 Address Setting Dimension Single gang PDL plate High impact ABS (white) Material Weight 45 grams Apartment Module (Vertical) 226-0003 Apartment Module (Horizontal) NB: By Special Order226-0005 SEARCH ZOOM PRINT EXIT INTERFACES Apollo XP95/DISCOVERY Intelligent Input/Output Unit with Isolator The Input/Output unit with Isolator provides a voltage free, single, pole, change-over relay output, a single, monitored switch input and an unmonitored, non-polarised opto-coupled input. • • • • • • It can report fault, switch open and switch closed levels Three visible LEDs Loop powered Voltage free Capable of switching up to 1A at 30V Built-in short circuit isolator Approvals: EN54-18/LPCB Voltage17-28vdc 1.2mA at 24vdc Quiescent current 3.5mA at 24vdc Max current Relay contact 1A at 30vdc Opto input 35vdc max Monitored input voltage 9-11vdc -20°C to +70°C (no icing) Operating temperature 0 to 95% (non condensing) Relative humidity IP Rating IP54 Size 150W x 90H x 48D mm Weight 240 grams XP95 Input/Output Unit with Isolator 55000-847APO Switch Monitor with Isolator The Switch Monitor with Isolator is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Ampac compatible analogue control equipment. • • • • Four input states – ’normal’, ’fault’, ’pre-alarm’ and ’alarm’ Two visible LEDs Loop powered Built-in short circuit isolator Approvals: EN54-18/LPCB NZ / PAGE 83 CONTACT AMPAC 17-28 dc 1.25mA at 24vdc 3.6mA at 24vdc 3A at 30vdc 9-11vdc -20°C to +70°C (no icing) 0 to 95% (non condensing) IP54 150W x 90H x 48D mm 240 grams Voltage Quiescent current Max current Max switching current Monitored input voltage Operating temperature Relative humidity IP Rating Size Weight XP95 Switch Monitor with Isolator HOME CONTENTS SEARCH ZOOM 55000-843APO PRINT EXIT INTERFACES Apollo XP95/DISCOVERY Intelligent Switch Monitor Plus with Isolator The Switch Monitor Plus with Isolator is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Ampac compatible analogue control equipment. Additional circuitry is incorporated to monitor flow switches and provide a time delay. It can also be used to reset a beam detector. • • • • • Output for resetting a remote detector Four input states – ’normal’, ’fault’, ’pre-alarm’ and ’alarm’ Two visible LEDs Selectable alarm delay for monitoring flow switches – 30 seconds Built-in short circuit isolator Voltage17-28vdc 1.25mA at 2 vdc Quiescent current Max current 4.2mA at 24vdc 3A at 30vdc Max switching current Monitored input voltage 9-11vdc Operating temperature -20°C to +70°C (no icing) 0 to 95% (non condensing) Relative humidity IP54 IP Rating Size 150W x 90H x 48D mm Weight 240 grams XP95 Switch Monitor Plus with Isolator 55000-841APO Approvals: EN54-18/LPCB Zone Monitor with Isolator The Zone Monitor with Isolator powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 Loop. • Loop powered • Visible LED • Built-in short circuit isolator Approvals: EN54-18/LPCB Voltage17-28vdc Quiescent current 4mA + detector load Alarm current 11mA at 24vdc EOL resistor value 5.1k ¹⁄₃ watt Maximum capacitor on zone terminals 50µF Zone voltage 19V ± 1V -20°C to +70°C (no icing) Operating temperature Relative humidity 0 to 95% (non condensing) IP Rating IP54 Size 150W x 90H x 48D mm Weight 230 grams XP95 Zone Monitor Unit with Isolator NZ / PAGE 84 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 55000-845APO EXIT INTERFACES Apollo XP95/DISCOVERY Intelligent Sounder Control Unit with Isolator The XP95 Sounder Control Unit with Isolator is used to control the operation of a zone of conventional sounders and report their status to the control panel. • A llows sounders to be operated continuously or be pulsed, 1 second on 1 second off • May be synchronized when in pulsed operation Approvals: EN54-18/LPCB Voltage17-28vdc 1.95mA at 24vdc Quiescent current 4.5mA Loop current max External supply 9-32vdc 1.25A 3mA at 32vdc External quiescent current 47mA + load External current max 1A at 30vdc Sounder circuit load max -20°C to +70°C (no icing) Operating temperature 0 to 95% (non condensing) Relative humidity IP54 IP Rating Size 150W x 90H x 48D mm 240 grams Weight XP95 Sounder Control Unit with Isolator 55000-852APO Three Channel Input/Output Unit with Isolator The Three Channel Input/Output unit with Isolator provides three voltage free, single pole, change-over relay outputs, and three monitored switch inputs. • S upervises one or more normally-open switches on each of the three inputs • Loop powered • Capable of switching up to 30V at 1A on each of the three outputs • Built-in short circuit isolator Approvals: EN54-18/LPCB NZ / PAGE 85 CONTACT AMPAC Voltage17-28vdc 3mA at 24vdc Quiescent current Max current 7.5mA at 24vdc Relay contact 1A at 30vdc Monitored input voltage 9-11vdc Operating temperature -20°C to +70°C (no icing) 0 to 95% (non condensing) Relative humidity IP Rating IP54 Size 250W x 175H x 75D mm Weight 621 grams XP95 Three Channel Input/Output Unit with Isolator HOME CONTENTS SEARCH ZOOM PRINT 55000-588APO EXIT INTERFACES Apollo XP95/DISCOVERY Intelligent Mains Switching Input/Output Unit The Mains Switching Input/Output Unit provides a voltage free, single pole, change-over relay output, and three monitored switch input. • S upervises one or more normally-open switches connected to a single pair of cables • Three visible LEDs • Capable of switching 250 vac at up to 5 amps Approvals: EN54-18/LPCB Voltage17-28vdc 3.5mA at 24vdc Quiescent current 5A at 240vac Rated load 2A at 48vdc Switching capacity max 1.25kva Switch input monitoring voltage 9-11vdc -20°C to +70°C (no icing) Operating temperature 0 to 95% (non condensing) Relative humidity IP Rating IP54 Size 150W x 90H x 48D mm Weight 240 grams XP95 Mains Switching Input/Output Unit NZ / PAGE 86 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 55000-875APO EXIT INTERFACES Apollo XP95/DISCOVERY Intelligent DIN-Rail Input/Output Unit The DIN-Rail Input/Output Unit provides a voltage free, single pole, change-over relay output, a single monitored switch input and an unmonitored, non-polarised opto-coupled input. • • • • • It can report fault, switch open and switch closed levels Three visible LEDs Loop powered Voltage free Capable of switching up to 30V at 1A Voltage17-28vdc 1.2mA at 24vdc Quiescent current 4.5mA at 24vdc Max current Relay contact 1A at 30vdc Opto input 35vdc max Monitored input voltage 9-11vdc -20°C to +70°C (no icing) Operating temperature 0 to 95% (non condensing) Relative humidity IP Rating IP20 Size 110H x 107W x 20Dmm Weight 95 grams XP95 DIN-Rail Input/Output Unit 55000-803APO DIN-Rail Output Unit The DIN-Rail Output Unit provides a voltage free single pole, change-over relay output. It is a simplified version of the Input/Output unit without circuitry for monitoring inputs. • Capable of switching up to 30V at 1A Voltage17-28vdc Quiescent current 720µA at 24vdc Max current 3.3mA at 24vdc Relay contact 1A at 30vdc Operating temperature -20°C to +70°C (no icing) Relative humidity 0 to 95% (non condensing) IP Rating IP20 110H x 107W x 20Dmm Size Weight 95 grams XP95 DIN-Rail Output Unit NZ / PAGE 87 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 55000-804APO PRINT EXIT INTERFACES Apollo XP95/DISCOVERY Intelligent DIN-Rail Switch Monitor The DIN-Rail Switch Monitor is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Ampac compatible analogue control equipment. • Four input states – ’normal’, ’fault’, ’pre-alarm’ and ’alarm’ • Two visible LEDs • Loop powered Voltage17-28vdc 730µA at 24vdc Quiescent current 5.6mA at 24vdc Max current Monitored input voltage 9-11vdc -20°C to +70°C (no icing) Operating temperature Relative humidity 0 to 95% (non condensing) IP20 IP Rating Size 110H x 107W x 20Dmm Weight 95 grams XP95 DIN-Rail Switch Monitor 55000-822-APO DIN-Rail Switch Monitor Plus The DIN-Rail Switch Monitor Plus is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Ampac compatible analogue control equipment. It has an output for resetting a remote detector and a selectable alarm delay making it suitable for monitoring flow switches. • • • • • Output for resetting a remote detector Four input states – ’normal’, ’fault’, ’pre-alarm’ and ’alarm’ Two visible LEDs Selectable alarm delay for monitoring flow switches Loop powered Voltage17-28vdc Quiescent current 730µA at 24vdc 5.6mA at 24vdc Max current Opto output voltage 5-30vdc 1mA Opto current Monitored input voltage 9-11vdc Operating temperature -20°C to +70°C (no icing) Relative humidity 0 to 95% (non condensing) IP Rating IP20 110H x 107W x 20Dmm Size Weight 95 grams XP95 DIN-Rail Switch Monitor Plus NZ / PAGE 88 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 55000-821-APO PRINT EXIT INTERFACES Apollo XP95/DISCOVERY Intelligent DIN-Rail Zone Monitor with Isolator The DIN-Rail Zone Monitor with Isolator powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 Loop. • Loop powered • Visible short circuit LED • Built-in isolator Voltage17-28vdc 4mA + detector load Quiescent current 11mA at 24vdc Max current 30V at 1A clean changeover Relay contact 19V ± 1V Zone voltage Operating temperature -20°C to +70°C (no icing) 0 to 95% (non condensing) Relative humidity IP54 IP Rating Size 110H x 107W x 20Dmm Weight 95 grams XP95 DIN-Rail Zone Monitor with Isolator 55000-812-APO DIN-Rail Sounder Control Unit (5 Amps) The DIN-Rail Sounder Control Unit (5 Amps) is used to control the operation of a zone of conventional sounders and report their status to the control panel. • • • Allows sounders to be operated continuously or be pulsed, 1 second on, 1 second off May be synchronized when in pulsed operation A n auto-coupled input is provided to monitor the state of the external power supply • S ounders can be operated individually or in groups • W ill accept a load of 5 amperes Voltage17-28vdc Loop quiescent current 1.9mA at 24vdc Loop max current 4.5mA at 24vdc External supply 9-50vdc External quiescent current 3mA at 32V 47mA + load External max current External max load 5A at 35vdc Operating temperature -20°C to +70°C (no icing) Relative humidity 0 to 95% (non condensing) IP Rating IP20 110H x 107W x 20Dmm Size Weight 95 grams XP95 DIN-Rail Sounder Control Unit-rated 5 Amp NZ / PAGE 89 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 55000-182-APO EXIT INTERFACES Apollo XP95/DISCOVERY Intelligent DIN-Rail Dual Isolator The DIN-Rail Dual Isolator provides two independent Isolators which sense and isolate short circuits on Discovery or XP95 loops and spurs. • • • • Loop powered Polarity sensitive Up to 20 detectors can be installed between isolators Allows fully isolated spurs Voltage17-28vdc 47µA at 24vdc Quiescent current -20°C to +60°C (no icing) Operating temperature 0 to 95% (non condensing) Relative humidity IP20 IP Rating Size 110H x 107W x 20Dmm 90 grams Weight DIN-Rail Dual Isolator 55000-802-AMP DIN-Rail Interface Enclosures DIN-Rail Interface Enclosures are available in two sizes and can be used for housing intrinsically safe (IS) barriers or DIN-Rail mounted interfaces. • Allows multiple interfaces to be housed together • IP67 NZ / PAGE 90 CONTACT AMPAC HOME XP95 IS DIN-Rail Interface Enclosure (4 Units) XP95 IS DIN-Rail Interface Enclosure (10 Units) CONTENTS SEARCH ZOOM PRINT 29600-239 29600-240 EXIT AUDIO VISUAL SIGNALLING XP95/DISCOVERY INTELLIGENT Audio Visual Signalling Ampac offers a wide range of Intelligent Audio Visual (AV) signalling devices for use in conjunction with its range of intelligent and conventional detectors and control panels. A versatile and functional range offering a huge choice for any application. • Sounder Bases combine an alarm sounder and detector base • Beacon Bases combine an alarm beacon and detector base •Sounder Beacon Bases combine an alarm sounder, beacon and detector base • Sounders are used to provide an audible indication of an alarm • Beacons are used to provide an visual flashing indication of an alarm •Sounder/Beacons are used to provide an audible and flashing indication of an alarm NZ / PAGE 91 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT AUDIO VISUAL SIGNALLING XP95/DISCOVERY INTELLIGENT SOUNDER BASES Integrated Sounder Base (NZ4512) The Integrated Sounder Base comprises a base sounder with integral mounting base and is for use with Discovery or XP95 ranges. It is designed for indoor use. • • • • • • • NZ4512 tones (No Voice) Two volume ranges – 55-75dB and 75-91dB Synchronisation of ‘alert’ and ‘evacuate’ tones Individual and group addressing Unique acoustic self-test Integrated base Isolator option Voltage (polarity sensitive) Quiescent current Max current (sounder operated) Max sounder output Operating temperature Relative humidity IP rating Size Weight 17-28 VDC 1.2mA 5mA 83dB(A) -20°C to +60°C (no icing) 0 to 95% (non condensing) IP21D 115Dia x 38H mm 140 grams Integrated Base Sounder Integrated Base Sounder with Isolator XP95 Red Base Sounder Cap XP95 White Base SounderCap Approvals: LPCB EN54-3/LPCB 45681-304-AMP 45681-0277-AMP 45681-293 45681-292 Ancillary Sounder Base (UK Tones) The Ancillary Sounder Base is a local-area sounder designed for indoor use. It can be connected only to detection systems using Discovery or XP95 detectors and control panels with appropriate software. • • • • • • UK tones (No Voice) Guaranteed sound output of 85dB(A) at 1 metre Current consumption of only 3mA Loop-powered Responds to signals from the associated detector – does not have an address of its own Adjustable volume control Voltage (polarity sensitive) Quiescent current Max current (sounder operated) Max sounder output Operating temperature Relative humidity IP rating Size Weight 17-28 VDC 100µA 3mA 85dB(A) -20°C to +60°C (no icing) 0 to 95% (non condensing) IP23D 115Dia x 38H mm 140 grams XP95 Ancillary Base Sounder 45681-276APO Approvals: LPCB EN54-3/LPCB NZ / PAGE 92 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT AUDIO VISUAL SIGNALLING XP95/DISCOVERY INTELLIGENT BEACON BASES Loop-Powered Beacon Base The Beacon Base is a loop-powered beacon combined with a standard XP95/Discovery mounting base. It is used to signal a fire alarm in enclosed areas. The Beacon Base can be used either with a detector fitted or with a cap for operation as a stand-alone alarm device. • • • • • Beacon flash rate of once per second (Red LEDs) Synchronisation of beacon flash Individual and group addressing Unique beacon self-test Isolator option CONTACT AMPAC HOME 17-28 VDC 300µA 3.1mA -20°C to +60°C (no icing) 0 to 95% (non condensing) IP21D 115Dia x 31H mm 109 grams XP95 Beacon Base with Isolator XP95 Red Base Sounder Cap XP95 White Base SounderCap Approvals: LPCB EN54-3/LPCB NZ / PAGE 93 Voltage (polarity sensitive) Quiescent current Max current Operating temperature Relative humidity IP rating Size Weight CONTENTS SEARCH ZOOM 45681-333APO 45681-293 45681-292 PRINT EXIT AUDIO VISUAL SIGNALLING XP95/DISCOVERY INTELLIGENT SOUNDERS Intelligent Open-Area Sounder (Sonos) The Intelligent Open-Area Sounder has been designed for use in open areas and can be connected to any Discovery or XP95 system. • • • • • • • NZ4512 tones (No Voice) Self-test fault monitoring Choice of tones Group addressing and synchronisation of alarm Weatherproof IP65 Comes with Isolating Base as standard Loop powered CONTACT AMPAC HOME 17-28 VDC 333µA 5mA 100dB(A) -10°C to +55°C (no icing) 0 to 95% (non condensing) IP65 104Dia x 95.5H mm 225 grams XP95 Open-Area Red Sounder with AUS/NZ (Sonos) XP95 Open-Area White Sounder with AUS/NZ (Sonos) Approvals: LPCB EN54-3/LPCB NZ / PAGE 94 Voltage (polarity sensitive) Quiescent current Max current (sounder operated) Max sounder output Operating temperature Relative humidity IP rating Size Weight CONTENTS SEARCH ZOOM PRINT EXIT 55000-003AMP 55000-004AMP AUDIO VISUAL SIGNALLING XP95/DISCOVERY INTELLIGENT BEACONS Loop-Powered Beacon The Loop-Powered Beacon is a local-area beacon designed for indoor use. The beacon has been developed as a supplement to sounders for use in situations where there is a risk that sounders will not be heard. • • • • • • • High intensity LED – more reliable than xenon beacons Automatic LED check Lockable Wide angle of visibility Enables DDA compliance Synchronised flash Can be used with Discovery or XP95 Voltage (polarity sensitive) Quiescent current Max current (beacon operated) Flash rate Operating temperature Relative humidity IP rating Size Weight 17-28 VDC 150µA 3mA 1Hz -20°C to +60°C (no icing) 0 to 95% (non condensing) IP23D 115Dia x 38H mm 140 grams XP95 Loop-Powered Beacon (Red) XP95 Loop-Powered Beacon (Clear- Red Flash) XP95 Loop-Powered Beacon (Amber) 55000-877AMP 55000-878APO 55000-879APO Intelligent Open-Area Beacon (Sonos) The Intelligent Open-Area Beacon has been developed for use in situations where there is a risk that sounders will not be heard. It is weatherproof and can be used outside. • • • • • • NZ / PAGE 95 Self-test fault monitoring Weatherproof IP65 Group addressing Synchronisation of alarm Comes with Isolating Base as standard Loop powered CONTACT AMPAC HOME Voltage (polarity sensitive) Quiescent current Max current (beacon operated) Flash rate Operating temperature Relative humidity IP rating Size Weight 17-28 VDC 333µA 3.1mA 1Hz -10°C to +55°C (no icing) 0 to 95% (non condensing) IP65 104Dia x 97.5H mm 205 grams XP95 Open-Area Red Beacon AUS/NZ (Sonos) XP95 Open-Area White Beacon AUS/NZ (Sonos) CONTENTS SEARCH ZOOM PRINT 55000-011AMP 55000-012AMP EXIT AUDIO VISUAL SIGNALLING XP95/DISCOVERY INTELLIGENT SOUNDER/BEACONS Intelligent Open-Area Sounder Beacon The Intelligent Open-Area Sounder Beacon has been designed for use in open areas and can be connected to any Discovery or XP95 system. • • • • • • • NZ4512 tones (No Voice) Gives two functions at one point Self-test fault monitoring Choice of tones Group addressing and synchronisation of alarm Comes with Isolating Base as standard Loop powered CONTACT AMPAC 17-28 VDC 333µA 8mA 100dB(A) 1Hz -10°C to +55°C (no icing) 0 to 95% (non condensing) IP65 104Dia x 97.5H mm 260 grams XP95 Open-Area Sounder Beacon Red with AUS/NZ (Sonos) 55000-007AMP XP95 Open-Area Sounder Beacon White with AUS/NZ (Sonos) 55000-008AMP Approvals: LPCB EN54-3/LPCB NZ / PAGE 96 Voltage (polarity sensitive) Quiescent current Max current (sounder/beacon operated) Max sounder output Flash rate Operating temperature Relative humidity IP rating Size Weight HOME CONTENTS SEARCH ZOOM PRINT EXIT AUDIO VISUAL SIGNALLING AMPAC BELLS (Conventional) Fire Alarm Bell 150mm – Model AFB-62M Voltage 8 to 16 VDC 20 to 28 VDC Operating current 50mA @ 12 VDC 30mA @ 24 VDC Size 150Dia x 70D mm 85 dB @ 1m Sound Level Operating temperature -20°C to +70°C (no icing) FinishRed Weight 980 grams •Motorised mechanism •Low current consumption •Red finish with FIRE lettering •Suitable for indoor use •Back box available 24 VDC AFB-62M 206-0010 Fire Alarm Bell 150mm – Model AFB-63 55mA @ 12 VDC Operating current 30mA @ 24 VDC 150Dia x 70D mm Size Sound Level 92 dB @ 1m Operating temperature -10°C to +55°C (no icing) FinishRed Weight 764 grams IP Rating IP33 •Motorised mechanism •Low current consumption •Red finish with FIRE lettering •Suitable for indoor use •Back box available – 206-0006 •Mountings for BESA roundJ & AFB back box •Isolation diode fitted 12 VDC AFB-63 24 VDC AFB-63 206-0011 206-0012 Bell Back Box • Allows surface mounting of bell •Screw thread conduit entry and protection for wiring terminals • Red finish • Weather seal Material Aluminium cast FinishRed Depth 40 mm Weight 270 grams Bell Back Box for 206-0012 and 206-0001 NZ / PAGE 97 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 206-0006 EXIT AUDIO VISUAL SIGNALLING AMPAC STROBES (Conventional) ASL-30 Xenon Beacon/Strobe •Red, amber, or blue lens options • Compact size • ABS/polycarbonate/acrylic construction • Easy-fit BESA, junction box adaptor/mounting base Voltage Current (at 24 VDC ) Size inc base Flash rate Operating temperature IP rating Weight inc base 20 to 28 VDC 1W 42mA 3W 135mA, 5W 155mA 77Dia x 65H mm 60 per minute -30°C to + 70°C IP65 106 grams ASL-30 Strobe 24Vdc Red 1 Watt ASL-30 Strobe 24Vdc Red 3 Watt ASL-30 Strobe 24Vdc Red 5 Watt ASL-30 Strobe 24Vdc Amber 1 Watt ASL-30 Strobe 24Vdc Amber 3 Watt ASL-30 Strobe 24Vdc Blue 1 Watt ASL-30 Strobe 24Vdc Blue 3 Watt ASL-30 Strobe Adapter Plate NZ / PAGE 98 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 208-0030 208-0032 208-0033 208-0034 208-0036 208-0038 208-0040 208-0024 PRINT EXIT AUDIO VISUAL SIGNALLING AMPAC STROBES (Conventional) ASL-32 Strobe • • • • • Synchronised operation Low profile High intensity output Polycarbonate / Acrylic construction Complete with mounting base Voltage 12 VDC Current80mA 3 Watts Rating Size inc base 85Dia x 81H mm Flash rate 60 per minute Operating temperature -20°C to + 40°C IP65 IP rating Weight - strobe 138 grams Approvals: ASL-32 Strobe (Red) ASL-32 Strobe (Blue) 208-0013 208-0014 ASL-86 Strobe • Red or Amber Lens • High intensity output • ABS / Polycarbonate / Acrylic construction • Combined Red & Amber surface mount unit available Approvals: Voltage 24 VDC Current140mA Rating 10 Watts Size inc base 100Dia x 88H mm Flash rate 75 per minute Operating temperature -20°C to + 60°C IP rating IP65 Weight – strobe 182 grams Weight – combined unit 719 grams ASL-86 Strobe (Red) ASL-86 Strobe (Amber) ASL-86 Strobe (Red & Amber) Combined Unit ASL-86 Strobe (Green) ASL-86 Strobe (Blue) NZ / PAGE 99 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 208-0007 208-0008 208-0011 208-0015 208-0016 EXIT AUDIO VISUAL SIGNALLING AMPAC STROBES (Conventional) Sonos Low Current Visual Warning Device The SONOS Low Current Visual Warning strobes are general purpose LED strobes for fire, security and industrial applications. The strobes come with the flexibility of individual Red, Amber and Clear strobes or combined Red/Amber strobe units complete with either a flush or surface mounting plate. The strobes utilises a full faced, translucent case which provides a much larger lens area and a greater spread of light. The strobes are suitable for use with AMPAC’s EV3000 system (both single and combined) and AMPAC’s fire panels (Single only). Simple ‘twist and click’ insertion avoids wiring and connection problems. • Low current consumption • Simple ‘twist and click’ insertion • Red, Amber and Clear options • Quick connect/disconnect • IP65 weather proof options (deep base units) for indoor and outdoor use Operating voltage 17 – 60 VDC 5mA Current drain Operating Temperature -25°C to +70°C IP Rating Shallow IP21 IP Rating Deep IP65 Colour Base White Red, Amber, Clear Colour Lens ApprovalsC-tick Sonos Low Current Visual Warning Device (Red) Sonos Low Current Visual Warning Device (Amber) Sonos Low Current Visual Warning Device (Clear) Sonos Low Current Visual Warning Device (Deep Base Only) 208-0060 208-0061 208-0062 208-0064 Combined Strobe for EV3000 208-0063 Combined Strobe for EV3000 Due to its low current draw the Sonos strokes can be connected in larger volumes onto the EV3000 visual output circuits. NZ / PAGE 100 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT AUDIO VISUAL SIGNALLING AMPAC STROBES (Conventional) Combined Strobe for EV3000 (Surface Mount) Item pictured is 208-0066 Indoor. The IP65 model uses the deep base to achieve an outdoor solution where required. Combined Strobe for EV3000 (Indoor) Combined Strobe for EV3000 (IP65 Outdoor) 208-0066 208-0065 Strobe Sign Plate Mounts directly behind the Single Red Sonos Strobe. Used outside the main building entrance which leads fire fighters to the fire indicator panel location. Outdoor strobes should always use the deep base. Directly behind the Sonos Model Strobe / Beacons Painted metal 1mm 120mm W X 160mm H Fixing Material Size Strobe Sign Plate NZ / PAGE 101 CONTACT AMPAC HOME CONTENTS SEARCH 207-0042 ZOOM PRINT EXIT AUDIO VISUAL SIGNALLING AMPAC REMOTE INDICATORS Fire Alarm Remote Indicator – Round •Detector activation indicator • 5mm Red LED • Compact size • Modern styling • For conventional or analogue detectors • Choice of legend • Voltage Current at 24v Size Weight 24 VDC 1.5mA 74Dia x 16H mm 26 grams Remote Indicator – Blank Remote Indicator – Fire Alarm in Concealed Space Remote Indicator – Fire Alarm in Roof Space Remote Indicator – Fire Alarm in Room Remote Indicator – Fire Alarm in Duct Remote Indicator – Fire Alarm in Cupboard Remote Indicator – Fire Alarm Under Floor Remote Indicator – Fire Alarm in Return Air Remote Indicator – Fire Alarm in Exhaust Duct Remote Indicator – Fire Alarm in Supply Air Duct Remote Indicator – Fire Alarm in Ceiling Remote Indicator – Fire Alarm Above Remote Indicator – Fire Alarm Remote Indicator – Detector Activated 209-0001 209-0004 209-0005 209-0006 209-0007 209-0008 209-0009 209-0010 209-0011 209-0012 209-0013 209-0014 209-0020 209-0023 Fire Alarm Flashing Indicator/Buzzer (with Mute) •Alarm activation indicator and buzzer •10mm red flashing LED •Buzzer (with mute facility) •Modern styling Voltage Current at 24v LED flash rate Buzzer Size Weight 24 VDC 43mA 45 per minute 3.8kHz @ 114dBA Flashing Indicator/Buzzer Flashing Indicator/Buzzer with Mute Switch NZ / PAGE 102 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 209-0017 209-0016 EXIT AUDIO VISUAL SIGNALLING ELECTRONIC SOUNDERS Vector Sounder • • • • • • • • Signal only to NZS4512 Conventional electronic sounder Low current consumption Sound output up to 93 dBA Built-in synchronising circuitry 2 or 3-wire configuration Available fitted with XP95/Discovery base Available in white Voltage 8 to 35 VDC 15mA @ 24 VDC max Alarm Current 90dB @ 1 metre with detector Sound Output 90dB @ 1 metre with lid SignalsNZS4512 Size 106 Dia x 25 H mm -20°C to +70°C Temperature range IP42 IP Rating Weight 125 grams Approvals: NZ5412 Vector Sounder (no Lid) Vector Sounder with UK Tones Vector Sounder Lid only 205-0011 205-0068 205-0017 Vantage Sounder • • • • • • • • • • • NZ4512 – signal only High output level – up to 100dB 3 selectable output levels Low current consumption 2 or 3-wire configuration Automatic signal changeover facility Built-in synchronising circuitry Surface mounted Quick-fit Lockable Base Shallow base supplied as standard Deep base option available Voltage 18 to 35 VDC Volume setting Low Med Current (mA @ 27VDC ) 7 12 Sound Output (dB @ 1m) 85 95 SignalsNZS4512 Size (shallow base) 93 Dia x 85 H mm Size (deep base) 93 Dia x 102 H mm Temperature range -20°C to +70°C Humidity 0 to 95% IP Rating (shallow) IP43 IP Rating (deep) IP65 Weight 193 grams Approvals: NZ5412 NZ / PAGE 103 CONTACT AMPAC Vantage Sounder Red with Shallow Base Vantage Sounder White with Shallow Base HOME CONTENTS SEARCH ZOOM PRINT High 19 100 205-0062 205-0063 EXIT AUDIO VISUAL SIGNALLING ELECTRONIC SOUNDER/BEACONS & BASES Vantage Combi • • • • • • • • • • • • NZ4512 – signal only High brightness LED strobe High output level – up to 100dB 3-level selectable sound output levels Low current consumption less than 70mA 2 or 3-wire configuration Automatic signal changeover facility ABS plastic – available in red or white Excellent lateral sound dispersion Built-in synchronising circuitry Surface mounted Quick-fit Lockable Base Voltage 18 to 35 VDC Low Med Volume setting 11 18 Current (mA @ 27VDC ) Sound Output (dB @ 1m) 85 95 SignalNZS4512 Flash rate 1 Hz 0.8 joule Flash energy Size (shallow) 93 Dia x 90 H mm Size (deep) 93 Dia x 107 H m Temperature range -20°C to +70°C Humidity 0 to 95% IP43 IP Rating (shallow) Weight 221 grams Approvals: NZ4512 Vantage Combi Red with Shallow Base Vantage Combi White with Shallow Base High 30 100 205-0066 205-0067 Vantage Deep Base • • • • Compatible only with Vantage and Vantage Combi sounders 20mm conduit entry facilitates surface mount installation of sounders Increases IP rating of sounders to IP65 Quick-fit Lockable Base Size (deep ) Temperature range Humidity IP Rating Weight 93 Dia x 37.5 H mm -20°C to +70°C 0 to 95% IP65 5 grams Vantage Deep Base only - Red Vantage Deep base only - White NZ / PAGE 104 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 205-0064 205-0065 PRINT EXIT ANCILLARIES Ancillaries Ampac offers a wide range of Intelligent Ancillary devices for use in conjunction with its range of intelligent and conventional detectors and control panels. A versatile and functional range offering a huge choice for any application. • Power Supplies • Manual Call Points •Fittings • Occupant Warning Systems- Amplified Sound Systems • Electro Magnetic Door Holders •Document Cabinets • Test Equipment •Sealed Rechargeable Lead Acid Batteries NZ / PAGE 105 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT ANCILLARIES POWER SUPPLIES MultiAmp PSU The MultiAmp PSU is a general purpose regulated power supply unit. MultiAmp PSU ABS •Available in 2A and 3A versions •Fault Relay Output •Fault indicator and Resettable Buzzer •Earth monitoring •Available in ABS (BX1) •Available in Metal cabinets (BX10) shallow and deep versions •2.5mm² cable terminals A set of two 7Ahr batteries may be housed in the BX1 and BX10 standard cabinet and a set of two 12Ahr batteries in the BX10 deep cabinet. (Maximum size based on Ampac battery specifications) The unit incorporates temperature sensing and compensation whereby a change in ambient temperature adjusts the battery charging voltage. The power supply will signal a Low Batt fault at 23.5 VDC. MultiAmp PSU Metal NZ / PAGE 106 Approvals: Complies with NZS4512 CONTACT AMPAC HOME CONTENTS Mains Supply Operating Voltage Supply Current Operating Temperature Relative Humidity Battery Capacity: BX1 and BX10 BX10 Deep Cabinet Maximum Charge Current Fault Relay Dimensions: ABS Cabinet (BX1) Metal Cabinet (BX10) Metal Cabinet (BX10 DEEP) 190 – 264 VAC 27.5 VDC ± 0.2 VDC 2A Current limited (2Amp Version) 3A Current limited (3Amp Version) 0°C to +40°C 25% - 75% 2 x 7Ahr 12V Sealed Lead Acid 2 x 12Ahr 12V Sealed Lead Acid 400mA (2A) 600mA (3A) NO,C,NC Contact rating: 1A @ 30VDC 300mm (H) x 360mm (W) x 100mm (D) 300mm (H) x 360mm (W) x 100mm (D) 300mm (H) x 360mm (W) x 200mm (D) MultiAmp PSU 2A NZ Version (ABS BX1) MultiAmp PSU 3A NZ Version (ABS BX1) MultiAmp PSU 2A NZ Version (Metal BX10) MultiAmp PSU 3A NZ Version (Metal BX10) MultiAmp PSU 2A NZ Version (Metal BX10 Deep Cabinet) MultiAmp PSU 3A NZ Version (Metal BX10 Deep Cabinet) BX10 Surround SEARCH ZOOM PRINT EXIT 4555-2110 4555-2120 4555-2210 4555-2220 4555-2310 4555-2320 ENC3016-A ANCILLARIES POWER SUPPLIES FastSense Power Supply Unit •2A power supply (incorporating battery charger) •Status indication – “POWER ON”, “BATTERY HIGH”, “BATTERY LOW”, “BATTERY FAIL” •Battery test facility •Termination for power supply output – Clearly labelled and adequate amount of room to terminate •Panel knockouts – top, side and rear of cabinet •Optional 6A power supply / battery charger may be fitted to the FastSense PLUS version Operating voltage Output voltage Max output current Battery capacity: FastSense 25 & FastSense 100 versions FastSense PLUS version Dimensions: FastSense 25 & FastSense 100 versions FastSense PLUS version Material Finish 240 VAC 27 VDC 2 Amps @ 27.6 VDC 7 Ah 12 Ah 300 H x 350 W x 130 D mm 320 H x 500 W x 160 D mm 1.6 mm Mild steel Powder coated Oyster Grey FastSense PSU – FastSense 25 & FastSense 100 versions FastSense PSU – FastSense PLUS version NZ / PAGE 107 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT 216-0065 216-0066 ANCILLARIES MANUAL CALL POINTS Manual Call Point – ACP-02 • • • • • • • • Manual call point available in conventional or addressable versions Resettable manual call point No glass to replace after operation Quick reset of manual call point without disassembly Test is by actual operation of manual call point Dual action Improved circuit design Compact design Approvals: NZ4512 Voltage Quiescent current Size (surface) Size (flush) Switch type Material Operating temperature Weight 27 VDC Conventional – <40uA Addressable – <1uA 88H x 88W x 54D mm 88H x 88W x 34D mm Single Pole Double Throw High impact ABS -20°C to +60°C 180 grams ACP-02 Conventional Red surface mount ACP-02 Conventional Red flush mount ACP-02 Addressable Red surface mount ACP-02 Addressable Red flush mount 4255-0100 4255-0150 4255-0200 4255-0250 Manual Call Point – ACP-03 • • • • ‘Double Action’ – Frangible glass and toggle switch action Wire protected connectors High reliability toggle switch operation High impact ABS, UV stabilised and resistant to heat Approvals: NZ4512 Voltage 17 to 28 VDC ConventionalConventionalAddressable (approved) Quiescent current 0uA 26uA 30uA Alarm current 0uA 14uA 16uA Contact rating 5A @ 24 VDC; 2A @ 250 VAC Size 119H x 129W x 56D mm Switch type Single Pole Double Throw Material High impact ABS Operating temperature -20°C to +60°C IP rating IP44 Weight 270 grams Conventional (Switch Only) Conventional Red Addressable Red Conventional White NZ / PAGE 108 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 4255-0500 4255-0700 4255-0600 4255-0510 PRINT EXIT ANCILLARIES MANUAL CALL POINTS Manual Call Point – Weatherproof ACP-05 • Suitable for outdoor use • Hermetically sealed switches • Back box supplied Contact rating Size Switch type Material Temperature range IP rating Weight 5A @ 24 VDC 110H x 110W x 65Dmm Single Pole High Impact ABS -10°C to +70°C IP67 200 g ACP-05 Conventional ACP-05 Addressable NZ / PAGE 109 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 4255-0800 4255-0801 PRINT EXIT ANCILLARIES ANCILLARIES Wall Boxes • Used for flush mounting devices such as manual call points and sounders • Suitable for MCP models ACP-01 & FP2 • Suitable for ‘Vara’ sounder Size Metal Plastic Weight Metal Plastic 72H x 72W x 47D mm 72H x 72W x 35D mm 153 grams 47 grams Wall Box Metal Wall Box Plastic NZ / PAGE 110 CONTACT AMPAC HOME CONTENTS SEARCH 268-0002 268-0009 ZOOM PRINT EXIT ANCILLARIES ELECTRO-MAGNETIC DOOR HOLDERS ADH-01 – Electro-Magnetic Door Holder • • • • • • Available in 24VDC with 50kg/50N holding force Release switch on housing Designed for surface mounted Adjustable door mounted keeper plate Separate screw terminals to maintain monitoring integrity Rear and side cable access Operating Voltage 15 to 29 VDC 55mA @ 24 VDC Operating Current 50kg Holding Force Housing White High Temperature ABS Operating Temperature -10° to +55° C Dimension (mm) 100h x 100w x 50d IP 51 IP rating Weight 750 g ApprovalC-Tick ADH-01 – Electro-Magnetic Door Holder 212-0012 H1360 – Surface Mount • 50kg/50N holding force •Retains fire doors in the open position •Cover in black ABS •Container in white aluminium •In built residual magnetism release pin •In built manual release switch •Fail safe operation Voltage Quiescent current Size exc anvil Weight inc anvil 24 VDC 100mA at 24 VDC 95H x 95W x 40D mm 700 grams H1360 – Surface Mount NZ / PAGE 111 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 212-0004 PRINT EXIT ANCILLARIES ELECTRO-MAGNETIC DOOR HOLDERS H1368 – Flush Mount • 50kg/50N holding force •Retains fire doors in the open position •Flush Mount •Cover in aluminium •Housing in galvanised steel •In built residual magnetism release pin •Fail safe operation Voltage Quiescent current Size exc anvil Weight inc anvil 24 VDC 100mA at 24 VDC 120H x 76W x 41D mm 650 grams H1368 – Flush Mount 212-0006 H1369 – Floor Mount • 50kg/50N holding force •Retains fire doors in the open position •Black steel bracket, die-cast aluminium mounting •In built residual magnetism release pin •In built manual release switch •Fail safe operation NZ / PAGE 112 CONTACT AMPAC HOME Voltage Quiescent current Size exc anvil Weight inc anvil 24 VDC 60mA at 24 VDC 100H x 110W x 80D mm 946 grams H1369 – Floor Mount CONTENTS SEARCH ZOOM 212-0001 PRINT EXIT ANCILLARIES ELECTRO-MAGNETIC DOOR HOLDERS H1370 – Floor or Wall Mount • 50kg/50N holding force •Retains fire doors in the open position •Black steel bracket, aluminium support •In built residual magnetism release pin •In built manual release switch •Fail safe operation Voltage Quiescent current Size exc anvil Base Arm 1370/15 Arm 1370/30 Weight inc anvil 24 VDC 60mA at 24 VDC 125H x 125W x 15D mm 40Dia x 150H mm 40Dia x 300H mm 1.277 kg H1370/15 – Floor or Wall Mount – 150mm arm H1370/30 – Floor or Wall Mount – 300mm arm 212-0007 212-0008 H1351 – Anvil •Retains fire doors in the open position •Cushioned magnetic support for 50kg electromagnets •Swivel adjustment 65H x 64W x 48D mm 18 grams Size Weight H1351 – Anvil 212-0009 Remote Door Release •Remotely releases fire doors held open by electro magnetic door holder Size Weight 70H x 110W x 10D mm 68 grams Remote Door Release NZ / PAGE 113 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 268-0003 PRINT EXIT ANCILLARIES ELECTRO-MAGNETIC DOOR HOLDERS MultiAmp-DH The MultiAmp-DH 250mA Door Holder Supply (DHS) provides up to 250mA of current at 24 VDC to operate door holders. The unit can operate as an “Automatic Door Release System” (ADRS) or respond to a secondary control. When configured as an ADRS, conventional detectors are installed and connected directly to the DHS. The detection circuit is monitored for alarm, open, or short circuit conditions. The presence of any one of these conditions will deactivate supply to the door holders and cause doors to be released. Alternatively doors may be released by a switched VDC input to the DHS, derived normally from a Fire Alarm Control Panel (FACP) or security system. The switched VDC input must be between 8 to 30VDC to release the doors. •Mains powered 240vAC supply •On board conventional detection zone •Switches off DH power in alarm condition or atlernatively remote switched input can trigger the door to release Mechanical High Impact ABS Material FinishWhite Dimension (mm) 91H X 149W x 40D (Recessed) 91H X 149W x 53D (Surface) Weight 400g packed Power Supply Mains Supply Voltage Door Holder Output Voltage Operating Temperature Relative Humidity 230 VAC +/- 10% @ 47-63Hz 24 VDC @ 250mA -5° to +45° C 25% to 95% Zone Detection Circuit No of Zones Zone Monitoring Zone Current Load EOL Value No of detectors/circuit 1 (one), 2-wire system Open and short-circuit 4.8mA max 3k3 ohm 40 (Max) Input Switched VDC Input Inactive state: 0 to 2 VDC Active state: 8 to 30 VDC MultiAmp-DH Flush Mount MultiAmp-DH Surface Mount NZ / PAGE 114 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 4510-1100 4510-1101 PRINT EXIT ANCILLARIES DOCUMENT CABINETS Document Cabinets AMPAC offers ABS and metal document cabinets designed to complement the range of AMPAC’s fire control panels. The cabinets can hold in excess of 100 A4 sheets of fire and security information relevant to the premises. The cabinets are fitted with a lockable front door for security and comes complete with an internal key holder bracket to allow easy storage of security keys. Whilst the ABS cabinet is available only in cool grey, there is a choice of Oyster Grey or Arch White with the metal cabinet option. • Metal and ABS versions available • Metal version available in Oyster Grey or Arch White •Provides the facility to hold documents i.e. Operation and Maintenance Manuals • Lockable front door • Internal key holder bracket • Designed to complement the AMPAC range of enclosures NZ / PAGE 115 CONTACT AMPAC HOME CONTENTS Colour Dimensions IP Rating Weight Key Type ABS – Cool Grey Metal – Oyster Grey Metal – Arch White ABS – 300H x 360W x 100Dmm Metal – 295H x 356W x 92Dmm IP30 ABS – 1kg Metal – 3kg 003 Key Document Cabinet Metal – Oyster Grey Document Cabinet Metal – Arch White SEARCH ZOOM PRINT 4210-0020 4210-0021 EXIT ANCILLARIES TEST EQUIPMENT Test Equipment •Access poles are used with interchangeable heads that fit onto the end of the pole •The equipment is suitable for use on a wide range of detectors •Poles are telescopic, nonconductive, toughened fibreglass •Light weight and simple to use Telescopic Pole 204-0001 Aerosol Smoke Dispenser 204-0004 NZ / PAGE 116 CO Test Can 204-0020 250ml Smoke Can 204-0014 150ml Smoke Can 204-0015 CONTACT AMPAC Telescopic pole – 6 metre Extension pole – 1.3 metre Universal detector removal tool Aerosol Smoke Dispenser Heat detector tester – cordless (head only) Smoke detector test set – 8.2 metre Smoke detector test set – 6.7 metre Smoke & cordless heat test set – 4.5 metre 250ml can of smoke (test set use only) 150ml can of smoke (hand held) Can of smoke for CO detectors (test set use only) Battery Baton for Cordless Tester Cordless Heat Detector 204-0017 HOME CONTENTS Head Removal Tool SEARCH ZOOM 204-0001 204-0002 204-0003 204-0004 204-0017 204-0009 204-0010 204-0018 204-0014 204-0015 204-0020 204-0021 Smoke & Cordless Heat Test Set PRINT EXIT ANCILLARIES TEST EQUIPMENT XP95 Test Set (Loop Manager Apollo) The XP95 Test Set is a self-contained, portable test unit capable of providing a number of useful functions in relation to individual detectors, ancillary devices or complete circuits of analogue addressable devices in the Apollo intelligent ranges. The main function of the test set is to help the engineer guarantee correct loop configuration before an active control panel is installed. • •User friendly LCD information display •Speedy commissioning •Option for hard copy of results •No unnecessary site visits •Significant cost reductions XP95 Test Set Ampac Item No. 204-0016 Discovery Programmer The Discovery Programmer is a portable test and configuration tool for Discovery smoke and heat detectors. Discovery Programmer 53832-030 •Look up the date of manufacture •Check the drift compensation value •Display and change the operating mode •Select/de-select LED flash mode •Tests detectors •Reads approval codes NZ / PAGE 117 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT ANCILLARIES TEST EQUIPMENT Flame Sensor Test Unit and Case The Flame Sensor Test Kit is a tool which is designed to test flame detectors without the need of real flames. Flame Sensor Test Unit and Case 29600-226 •Mimics the characteristics of real flames NZ / PAGE 118 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTACT Ampac Pacific Ltd- Auckland Ampac Pacific Ltd- Christchurch Unit 4/101 Diana Drive Unit D/ 163 Wordworth Street GlenfieldChristchurch New ZealandNew Zealand Telephone: +64 9443 8072 Fax: +64 9443 8073 Email: [email protected] Web: www.ampac.net Telephone: +64 3974 1350 Fax: +64 3974 1351 Email: [email protected] Web: www.ampac.net As part of Ampac’s commitment to continuous improvement, specifications may change without notice. Version NZ/16-05-2012 Planned, written, designed and produced by Right Angle • www.rightangle.co.uk NZ / PAGE 119 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement