eCATALOGUE South East Asia WOR LD LEA D ER O F INNOVATIV E SOLUTIO NS IN FIRE DETECT I O N AN D AL ARM S YS T E MS SEA/PAGE 1 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT AMPAC TECHNOLOGIES Ampac Technologies was founded in 1974. With the adoption of three basic core principals, we have grown from a small innovative Australian entity, to a global operation in key markets. Our business is the design, manufacture and distribution of world leading fire detection and alarm systems for commercial, industrial, and mulitresidential complexes. CONTROL PANELS 3 GasRelease Conventional .................................................................................................. 3 LoopSense Intelligent .......................................................................................................... 8 FireFinder Conventional/Intelligent .......................................................................... 13 DETECTORS23 Orbis Conventional ............................................................................................................... 23 DS-Series .................................................................................................................................... 27 XP95 Intelligent ...................................................................................................................... 31 Discovery Intelligent ........................................................................................................... 37 At Ampac, we strive to maintain and improve the vitality of our customer relationships for it is through understanding the needs of our customers that we can truly achieve sustained long term growth. Our aim is to ensure that the entire life cycle of our products is supported by our comprehensive after sales service. INTERFACES45 XP95/Discovery Intelligent.............................................................................................. 45 Ampac I/O Devices ............................................................................................................... 55 It is a business we are very passionate about. Along the way, we have gained the reputation of a company that operates with integrity coupled with a clear focus and commitment – providing customers at every level with superior customer service. It is a philosophy we continue to improve upon. Ampac is a business focused on long term growth. While we always consider the implications on a wider scale, no detail, imperative for the success of any undertaking, is compromised. WIRELESS TECHNOLOGY 58 Xpander Detectors ............................................................................................................... 58 Xpander Call Points ...............................................................................................................60 Xpander Sounders/Sounder Beacons .......................................................................61 Xpander Ancillaries .............................................................................................................. 62 AUDIO VISUAL SIGNALLING 63 XP95/Discovery Sounder, Beacon & Sounder Beacon Bases .................... 64 XP95/Discovery Sounders, Beacons & Sounder Beacons ............................ 67 Ampac Bells, Strobes & Remote Indicators ............................................................ 72 Fulleon Sounders & Beacons .......................................................................................... 75 KAC Manual Call Points ...................................................................................................... 79 Klaxon Sounders & Beacons ........................................................................................... 81 (HEAD OFFICE) SEA/PAGE 2 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS GasRelease Conventional Agent Release Panel GasRelease is the new compact conventional 3 zone fire control panel that includes additional circuitry for controlling the release of extinguishing agents into protected areas. Fully compliant with EN12094-1, GasRelease is ideal for applications housing expensive, dangerous or irreplaceable items. Supported by a wide range of ancillaries, GasRelease is a powerful partner for automatic fire suppression systems. Functions as a standard three zone fire panel with additional circuitry for controlling the release of fire-suppressing gas into protected areas • Unique 128 x 64 pixel graphical display facilitates straightforward system programming Includes a pull-down front panel manual release button and two keyswitches for • accessing the panel’s functions and toggling between auto/manual mode • Three conventional sounder circuits (two x 1st stage, one x 2nd stage) • Low quiescent current – less than 40mA • Abort and hold inputs • Time-stamped event log • RS485 connections for up to eight flush or surface remote status units with their own LCD, manual release and mode (auto/manual) switches. Single gang economy status units (without an LCD) are also available • Extensive range of commissioning and engineering functions • Ideal for use in computer rooms, telecommunication centres, archive stores, control rooms, generator rooms, museums, etc SEA/PAGE 3 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS GASRELEASE Conventional Power Supply Input Voltage Output Voltage Battery Type (maximum) Quiescent Current Power Supply PSU output current 230VAC, 50/60Hz 24VDC nominal 7 Ahr 40mA 3 Amp Switch Mode 1.5 Amp cont. 3 Amp peak Zone Circuits Detector Circuits Fault Supervision Cable Requirements Max Cable Length Max Detectors/Devices per zone End of Line (EOL) value 3 x fully monitored O/C & S/C 2 core 1.5 to 2.5mm 250m 32 6K8 ohm ± 5%, 0.25W General Outputs Alarm Sounder Outputs 3 x fully monitored Fault Supervision O/C & S/C Sounder Output Rating 19-28VDC @ 200mA each End of Line (EOL) value 6K8 ohm ± 5%, 0.25W Auxiliary Relay Outputs 6 x 1 Amp rated @ 30VDC Fire Local Fire Extract 1st Stage 2nd Stage Fault Auxiliary Power Output 19-28VDC 100mA fused GasRelease Panel Extinguishing Release Outputs Extinguishant Release Output Extinguishant Release Time Delay Extinguishant Release Duration Extinguishant Release Flooding Time Extinguishant Output EOL SEA/PAGE 4 CONTACT AMPAC HOME CONTENTS SEARCH 1 amp @19-28VDC for 5 mins 0-60 seconds – adjustable 0-300 seconds – adjustable 60-1740 seconds – adjustable System Line Terminator (part number 2980-0005) ZOOM PRINT EXIT CONTROL PANELS GASRELEASE Conventional Inputs Supervised Inputs 6 x fully monitored Manual release Flow switch Low Pressure Mode Hold Abort End of Line (EOL) value 6K8 ohm ± 5%, 0.25W Remote Inputs 4 x Switched inputs Silence Alarm Fault Reset GasRelease Panel Communication Outputs Remotes Status Units (RSU) Economy Status Units (ESU) RS485 4 wire (2 wire 24VDC power – 2 wire RS485) 4 wire (2 wire 24VDC power – 2 wire Mode select) Environmental Operating temperature Relative Humidity IP Rating -5°C to +40°C (no icing) 0 to 95% (non condensing) IP30 indoor use only Mechanical Material Finish Dimensions Weight Back box metal – lid plastic Light Grey 297H x 467W x 99D mm 4.2kg (without batteries) GasRelease Panel – 3 Zones SEA/PAGE 5 CONTACT AMPAC HOME CONTENTS SEARCH 2983-0304 ZOOM PRINT EXIT CONTROL PANELS GASRELEASE Conventional Remote Status Unit • • • • • • • Remote indication of system status Clear two colour LCD display and LED indicators Plain text display Mode select – auto/manual key switch Dual action extinguishant manual release button Flush or surface mounting options 4 wire RS485 connection Voltage Quiescent current Communication input Max no. of RSUs Monitored inputs Status display Dimensions Weight 21-28 VDC 10 mA RS485 4 wire [2 wire 24 VDC power 2 wire RS485] 8 per system 3 - Abort, Hold, Mode 128 x 64 pixel 2 colour backlit LCD 250H x 175W x 53Dmm (flush) 240H x 160W x 51Dmm (surface) 1600 grams Remote Status Unit (Flush) Remote Status Unit (Surface) 2980-0001 2980-0002 Economy Status Unit • • • • • • Remote indication of system status Mode select – auto/manual key switch Simple LED indication Flush mounting Surface mounting option with single gang back box 4 wire connection Voltage Quiescent current Communication input Max no. of ESUs Dimensions Weight 21-28 VDC 5 mA 4 wire [2 wire 24 VDC power 2 wire mode select] 8 per system 87H x 87W x 35Dmm 70 grams Economy Status Unit SEA/PAGE 6 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 2980-0003 PRINT EXIT CONTROL PANELS GASRELEASE Conventional Extinguishant Hold Off/Abort Button • • • • • Delays or cancels the extinguishing release sequence Monitored input to the GasRelease panel 2 wire connection Single gang surface mounting Monitored for open and short circuit faults Monitored input threshold End of Line Ingress protection Dimensions Weight 8K to 2K (normal) 1.8K to 200ohms (active) 6K8 IP66 93H x 93W x 78Dmm 250 grams Extinguishant Hold Off/Abort Button 2980-0006 Output Expansion Relay Board • Five voltage free relay outputs • Installed within and directly controlled by the GasRelease panel • Outputs for Reset, Mode, Discharged, Hold and Abort Relay outputs Max no. of boards Operating current Dimensions Weight 5 x 30 VDC 1 Amp 1 per system 8 mA per active relay 160 x 70mm 60 grams Output Expansion Relay Board 2980-0004 System Line Terminator •Terminates the GasRelease panel extinguishing output to the release actuators • Maximum two solenoids or multiple Metrons™ are supported • Suitable for mounting in an appropriate junction box • Red active LED indicator Dimensions Weight 55H x 55W x22Dmm 27 grams System Line Terminator SEA/PAGE 7 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 2980-0005 PRINT EXIT CONTROL PANELS LoopSense Intelligent Control Panel 952a LoopSense is an Intelligent Analogue Addressable Fire Alarm Control Panel. Available in one or two loops, the LoopSense comes packed with options and features that facilitate flexibility, ease of installation and commissioning. • Clear back-lit 40 x 4 line character LCD • Advanced balanced loop design for noise rejection • 500mA loop current • Integrated 32-Zone Indication card • Laptop connection via USB 2.0 or RS232 port • Auto Learn Facility • Removable front door and chassis • LoopMaster – user friendly programming software • Fully approved to EN54-2 & 4 by the Loss Prevention Certification Board (LPCB) SEA/PAGE 8 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS LOOPSENSE Intelligent Power Supply (General) Output Voltage Battery Type (maximum) Battery Discharged Cut Off Voltage LoopSense – ABS Cabinet LoopSense SmartTerminal Repeater SEA/PAGE 9 CONTACT AMPAC LoopSense – Metal Cabinet (Approved to EN54-2 & 4) LoopSense SmartTerminal Slim Line Repeater HOME MetalABS 27.5VDC +/- 0.1VDC 17.2Ah 21VDC 27.5VDC +/- 0.1VDC 7.0Ah 21VDC Base Panel Quiescent Current 1 Loop Panel 2 Loop Panel 115mA 135mA 115mA 135mA Loop Loop current Detectors/Devices per Loop Cabling Requirements Fault supervision Protocol 500mA max 126 max 2 core 1.5 to 2.5mm O/C, S/C, overcurrent XP95, Discovery 500mA max 126 max 2 core 1.5 to 2.5mm O/C, S/C, overcurrent XP95, Discovery Outputs Alarm Sounder Outputs Relay outputs Open Collector Output Auxiliary VDC 4 x supervised/programmable 24VDC @ 500mA max 3 x programmable Voltage free 24VDC @ 1A 2 x programmable – 30mA 2 x protected/programmable 24VDC @ 500mA 4 x supervised/programmable 24VDC @ 500mA max 3 x programmable Voltage free 24VDC @ 1A 2 x programmable – 30mA 2 x protected/programmable 24VDC @ 500mA Inputs Supervised 4 x O/C, S/C, 10K EOL 4 x O/C, S/C, 10K EOL Communications Port Internal to LoopSense External to LoopSense Printer port PC Interfacing RS485 RS485 RS232 or Parallel RS232 or USB 2.0 RS485 RS485 RS232 or Parallel RS232 or USB 2.0 CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS LOOPSENSE Intelligent Electrical Power Supply Input Voltage Protection Output Current Charger Current LoopSense – ABS Cabinet LoopSense SmartTerminal Repeater LoopSense – Metal Cabinet (Approved to EN54-2 & 4) LoopSense SmartTerminal Slim Line Repeater MetalABS 3A PSU version 204 - 264VAC 3Amp M205 3Amps 600mA 2A PSU version 204 - 264VAC 2Amp M205 1.8Amps 400mA Environmental Operating temperature Relative humidity IP rating -5°C to +55°C (no icing) -5°C to +55°C (no icing) 25% to 75% (non condensing) 25% to 75% (non condensing) IP30 IP30 Mechanical Material Finish Dimensions Weight 1.2mm steel Surf Mist Ripple 425H x 400W x 125Dmm 7kg ABS Blend/High Impact Cool Grey 300H x 360W x 100Dmm 2.5kg NEW LoopSense Intelligent Control Panel 1 Loop, 500mA capacity, 32 Zone, 4 alarm circuits, 2 Amp PSU, ABS 2 Loop, 500mA capacity, 32 Zone, 4 alarm circuits, 2 Amp PSU, ABS 8281-0101 8281-0201 1 Loop, 500mA capacity, 32 Zone, 4 alarm circuits, 3 Amp PSU, Metal * 1 Loop, 500mA capacity, 32 Zone, 4 alarm circuits, 3 Amp PSU, Printer, Metal 2 Loop, 500mA capacity, 32 Zone, 4 alarm circuits, 3 Amp PSU, Metal * 2 Loop, 500mA capacity, 32 Zone, 4 alarm circuits, 3 Amp PSU, Printer, Metal 8281-0105 8281-0106 8281-0205 8281-0206 NEW LoopSense SmartTerminal Repeaters SmartTerminal Repeater without PSU SmartTerminal Repeater with 2 Amp PSU 4380-0011 4380-0012 SmartTerminal Slim Line Repeater without PSU 4380-0013 Flush Mount Surround for LoopSense Metal 2nd Loop Activation Key ENC 3004-A 8210-0001 * Approvals: EN54-2 & 4/LPCB SEA/PAGE 10 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS LOOPSENSE Intelligent Relay Board • • • • • Provides volt free change over contacts 8 relay outputs per board Max 1 per LoopSense system Remote version available – DIN Mount chassis Remote version communication via RS485 serial link 24 VDC 2.4 mA 80 mA 3 amp at 24 VDC -5°C to +55°C (no icing) 0 to 95% (non condensing) 130 grams Voltage Quiescent current Max current Relay contact rating Operating temperature Relative humidity Weight Relay Board Relay Board (Remote) 4310-0050 4310-0055 Sounder Board • Provides 8 monitored switched 24 VDC outputs per board • Max 1 per LoopSense Voltage Quiescent current Max current Output rating (ea) Operating temperature Relative humidity Weight 24 VDC 5.6 mA 26 mA 500 mA at 24 VDC -5°C to +55°C (no icing) 0 to 95% (non condensing) 100 grams Sounder Board SEA/PAGE 11 CONTACT AMPAC HOME CONTENTS SEARCH 4310-0060 ZOOM PRINT EXIT CONTROL PANELS LOOPSENSE Intelligent 8 Zone Conventional Board •Supports up to eight conventional zones •Selectable end of line device 3K3, 4K7, 6K8, 10K or 10µF capacitor • Supports head removal requirement on each zone • Supports up to 40 conventional devices per zone circuit (Apollo Series 65 or Orbis) •Programmable latching and non-latching (self-resetting) input on each zone circuit • Fully compatible with other Ampac LoopSense Add-Ons Voltage Quiescent current Alarm current Operating temperature Relative humidity Size Weight 24 VDC 15mA (including capacitive EOL current) plus device current 43mA (one circuit in alarm) -5°C to +55°C (no icing) 0 to 95% (non condensing) 72.5 x 155mm 120 grams 8 Zone Conventional Board SEA/PAGE 12 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 4310-0082 PRINT EXIT CONTROL PANELS FireFinder Conventional / Intelligent Fire Alarm Control Panel FireFinder is a state of the art multi microprocessor controlled Intelligent Fire Alarm Control Panel. Modular in design, the FireFinder provides flexibility and versatility that can be configured to operate with both intelligent analogue addressable and conventional devices in the one system. Available in single loop or multiple loop configurations, the FireFinder supports the leading Apollo XP95 and Discovery detector protocols. The Ampac ConfigManager software tools provide a powerful combination with the FireFinder to configure the system operational and functional characteristics of an installation. Enhanced networking capabilities offer the user extended applications with FireFinder incorporating a Master/ Slave Fire control panel arrangement, true Peer to Peer systems, data gathering panels and SmartGraphics a PC based application for the supervision, monitoring and control of larger fire management systems. • • • • • • • • • • • Clear back-lit 40 character 8 line LCD display Programming options via the front panel or laptop computer Remote system interrogation and diagnostics Extensive Alarm Management resources Self Auto Learn capabilities Day Night sensitivity settings Versatile multi processor architecture Event log and printer options SPOT – Single Person Operation Test Flexible modular expansion and panel Add Ons SmartTerminal repeater options SEA/PAGE 13 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent FireFinder CP10-1/SP1X Conventional / Intelligent Control Panel with glazed outer door SEA/PAGE 14 CONTACT AMPAC FireFinder CP10-4/SP8X Conventional / Intelligent Control Panel with glazed outer door HOME Electrical Mains Supply Voltage Output Voltage Power Supply Current Quiescent Current (1 Loop 32 Zone LEDs) 85-264 VAC 27 VDC 5.6 Amps 280-330 mA Outputs Sounder 1-1 – Programmable Monitored Sounder 1-2 – Programmable Monitored Sounder 2 – Programmable Monitored F.A.R.E. Fire Alarm Routing Equipment – Monitored F.W.R.E. Fault Warning Routing Equipment – Monitored F.A.R.E. Fire Alarm Routing Equipment – Relay Output F.W.R.E. Fault Warning Routing Equipment – Relay Output Disable Relay Alarm Relay Valve Monitor Relay Battery Fail Relay 2 Amps 2 Amps 1 Amp 1 Amp 1 Amp Voltage Free 1 Amp @ 30v Voltage Free 1 Amp @ 30v VFCO 1 Amp @ 30v VFCO 1 Amp @ 30v VFCO 1 Amp @ 30v VFCO 1 Amp @ 30v Environmental Operating temperature Relative humidity IP rating -5°C to +55°C (no icing) 25% to 75% (non condensing) IP30 Mechanical Materials Construction Case Finish CP10-1/SP1X Dimensions CP10-4/SP8X 1.2mm steel Modular Red Ripple 500H x 400W x 140D mm 840H x 515W x 140D mm CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent SINGAPORE FireFinder CP10-1 Conventional Control Panel 16 zone FireFinder CP10-4 Conventional Control Panel 16 zone 8565-0100 8565-0200 FireFinder CP10-1 Intelligent Control Panel 1 loop 8565-1100 FireFinder CP10-4 Intelligent Control Panel 1 loop 8565-4100 Approvals: Singapore Code of Practice CP10:2005 FireFinder CP10-1/SP1X Conventional / Intelligent Control Panel with glazed outer door FireFinder CP10-4/SP8X Conventional / Intelligent Control Panel with glazed outer door MALAYSIA FireFinder SP1X Conventional Control Panel 16 zone FireFinder SP8X Conventional Control Panel 16 zone 8560-0100 8560-0200 FireFinder SP1X Intelligent Control Panel 1 loop 8560-1100 FireFinder SP8X Intelligent Control Panel 3 loop 8560-4300 Approvals: MS1404: Part 4: 1996 SEA/PAGE 15 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent Dot Matrix Panel Printer •The dot matrix printer provides hardcopy activity report •Alarms, faults, isolates and system logs may be printed •3 colour status LED •Self test mode •Easy maintenance for replaceable ribbon cassette and paper roll •Print loop statistics Voltage Quiescent current Character size Operating temperature Relative humidity Weight 5 VDC 1A @ 5 VDC 5 x 7 dots -5°C to +55°C (no icing) 25 to 95% (non condensing) 380 grams Dot Matrix Panel Printer 159-0111 MIS1981 Paper – 10 rolls RibbonMIS1982 SmartTerminal Repeater The SmartTerminal Repeater is an LCD annunciator designed to remotely display the status and provide control of the FireFinder Fire Alarm Control Panel. •4 line 40 character backlit LCD display •2 wire RS485 communication to the FireFinder • Reset, Activate or Silence alarms • Programmable to display Alarms and/or Faults and Isolates •Flush or surface mounting • Slimline version available Voltage Quiescent current (backlight/buzzer off ) Max current (backlight/buzzer on) Max distance from main panel Auxiliary output (monitored) Operating temperature Relative humidity Size SmartTerminal Repeater SmartTerminal Slimline Repeater Weight SmartTerminal Repeater SmartTerminal Slimline Repeater 24 VDC 12.4 mA 44 mA 1.2 km 27 VDC 500 mA -5°C to +55°C (no icing) 25 to 95% (non condensing) 300H x 360W x 100Dmm 195H x 324W x 52Dmm 2.5 kg 1 kg SmartTerminal Repeater without PSU SmartTerminal Repeater with 2 Amp PSU SmartTerminal Slimline Repeater without PSU SEA/PAGE 16 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 4380-0001 4380-0002 4380-0003 EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent Network Interface Card (NIC) •The NIC gives the FireFinder network capabilities via the RS422 communications port • Provides an additional RS232 communications port when connected to Controller Interface Card (CIC) •High level interface for Building Management or ModBus protocol for SmartGraphics and PLCs •The NIC can be isolated from other network devices • Loop In/Loop Out for easy installation Voltage Quiescent Current Available Ports Max distance (between NICs) Cable requirements Operating temperature Relative humidity Weight 24 VDC 65 mA RS422 – network RS232 – serial comms 1.2km RS422 – 2 pair twisted/screened RS232 – 1 pair twisted/screened -5°C to +55°C (no icing) 0 to 95% (non condensing) 225 grams Network Interface Card – NIC (4 wire) 159-0053 Controller Interface Card (CIC) • The CIC gives the FireFinder additional RS232 and RS485 capabilities •Acts as a Controller board interface when used with a NIC •The RS232 communications port provides for Building Management, ModBus or serial printer •The RS485 communications port provides for Building Management, ModBus or LED repeaters Voltage Quiescent Current Available Ports Max distance Cable requirements Operating temperature Relative humidity Weight 24 VDC 5 mA RS232 – serial communications RS485 – half duplex multi drop RS232 – 15m RS485 - 1.2km RS232 – 1 pair twisted/screened RS485 – 1 pair twisted/screened -5°C to +55°C (no icing) 0 to 95% (non condensing) 125 grams Controller Interface Card (CIC) SEA/PAGE 17 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 159-0054 PRINT EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent Analogue Loop Upgrade Kit •This kit adds an intelligent analogue loop to the FireFinder Control Panel •For an odd numbered loop upgrade the kit consists of an I/O CPU module, cable and termination card •An even numbered loop upgrade consists of an I/O CPU module and cable Voltage Quiescent current Loop current Operating temperature Relative humidity Weight 24 VDC 40 mA 250 mA max. -5°C to +55°C (no icing) 0 to 95% (non condensing) 200 grams 1 Loop Upgrade Kit – even numbered loop 1 Loop Upgrade Kit and processor – odd numbered loop 159-0001 159-0003 Loop Module Expansion Kit •Expands the capacity of the FireFinder to accommodate a further four loops, 64 conventional zones, four I/O modules or any combination of the above •Requires a main controller board Voltage Quiescent current Operating temperature Relative humidity Weight 24 VDC 5 mA -5°C to +55°C (no icing) 0 to 95% (non condensing) 110 grams Loop Module Expansion Kit SEA/PAGE 18 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 159-0045 PRINT EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent 8 Way Serial Relay Output Board •Each serial relay output board offers 8 voltage free relay outputs, each rated at 5 amps, 24 VDC •Each relay has a single normally open/close volt-free contact extended to a wire-protected screw terminal •The serial 8-way relay is driven directly from the main controller board Voltage Quiescent current Relay output current Operating temperature Relative humidity Weight 24 VDC 5 mA 5 Amps at 24 VDC -5°C to +55°C (no icing) 0 to 95% (non condensing) 190 grams 8 Way Serial Relay Output Board 159-0072 4 Plus 4 Bell Monitor Board •The 4 Plus 4 Bell Monitor has screw terminals for 4 voltage free contacts and 4 switched 24V DC sounder outputs • The outputs are programmable and monitored for open or short circuit • The board connects directly to the main controller board Voltage Quiescent current Relay output current Sounder output current Capacity Operating temperature Relative humidity Weight 24 VDC 20 mA 1 Amp at 24 VDC 1 Amp each 8 boards per main controller -5°C to +55°C (no icing) 0 to 95% (non condensing) 250 grams 4 Plus 4 Bell Monitor Board SEA/PAGE 19 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 159-0069 PRINT EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent 8 Way Bell Monitor Board •The 8-Way Bell Monitor has 8 switched 24V DC sounder outputs • The outputs are programmable and monitored for open or short circuit • The board connects directly to the main controller board Voltage Quiescent current Max sounder output current Max output current Operating temperature Relative humidity Weight 24 VDC 20 mA 1 Amp each 4 Amps per board -5°C to +55°C (no icing) 0 to 95% (non condensing) 250 grams 8 Way Bell Monitor Board 159-0071 16 Way Conventional Zone Card • Adds 16 conventional Alarm Zone Circuits •Kit consists of an I/O CPU module, cable and 16 zone termination card •Supports up to 40 conventional detectors (Series 65 or Orbis) per zone •Fixed 3K3 End-Of-Line device Voltage Quiescent current Operating temperature Relative humidity Weight 24 VDC 145 mA -5°C to +55°C (no icing) 0 to 95% (non condensing) 185 grams 16 Way Conventional Zone Card SEA/PAGE 20 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 159-0005 PRINT EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent Panel Mounted LED Indicators •Provide flexibility to include additional LED indicators to the FireFinder SP1X and SP8X •Available in three versions: – 32 zone alarm only indication (red) – 16 zone alarm/fault indication (red/amber) – 32 zone general indication (amber) • Serial connection to the FireFinder panel •Simple clip installation •Indicators remain illuminated until reset by the panel •Indicators are tested by the FireFinder panel’s lamp test control SEA/PAGE 21 CONTACT AMPAC HOME CONTENTS Voltage Quiescent current Max current Operating temperature Relative humidity Weight 27 VDC 30 mA 40 mA -5°C to +55°C (no icing) 0 to 95% (non condensing) 100 grams FireFinder SP1X 32 Zone Alarm Only Indication (Red) FireFinder SP8X 32 Zone Alarm Only Indication (Red) 159-0106 159-0089 FireFinder SP1X 16 Zone Alarm/Fault Indication (Red/Amber) FireFinder SP8X 16 Zone Alarm/Fault Indication (Red/Amber) 159-0107 159-0108 FireFinder SP1X 32 Zone General Indication (Amber) FireFinder SP8X 32 Zone General Indication (Amber) 159-0123 159-0124 SEARCH ZOOM PRINT EXIT CONTROL PANELS FIREFINDER Conventional / Intelligent Remote Mounted LED Indicators •The remote LED indicator boards provide facilities to mimic the FireFinder zonal LEDs and switches •Connects to the RS485 communications bus via the controller interface card •Allows the custom design of geographic site layout mimics •Each termination board connects up to 32 zone LEDs – 31 boards maximum – total 992 zone indications FireFinder LED Mimic Driver Voltage Quiescent current Max current Communication mode Baud rate Communication cable No. of boards No. of zones Buzzer external max current On board status indication Common inputs Operating temperature Relative humidity 27 VDC 8 mA max 100 mA RS485 19200 max 1 x pair twisted and screened 31 max 992 zones max 20 mA Power on – green Normal – green Fault – yellow Reset Lamp test Buzzer mute Bell isolate Manual evacuate -5°C to +55°C (no icing) 0 to 95% (non condensing) FireFinder LED Mimic Driver Mimic Output Termination Board Remote Expansion LED Board Mimic Output Termination Board 302-7150 BRD85MOTB1-A 302-7330 Remote Expansion LED Board SEA/PAGE 22 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS Orbis Conventional Detectors Orbis is a range of conventional detectors which has been developed with sophisticated technology previously only found in intelligent detectors. Orbis is a range with modern styling and incorporates a mounting base wihich saves installation time. • Automatic drift compensation with DirtAlert® warning • Patented FasTest® which reduces the time taken to test detectors • SensAlert® uses a flashing LED to indicate that the sensor is not operating correctly • StartUpTM for fast commissioning • Attractive and compact design • Electrically compatible with Series 60 and Series 65 • Wide voltage and operating temperature ranges • Algorithms for transient rejection • Flashing LED option • 360° visibility of LEDs • Insect resistant SEA/PAGE 23 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS ORBIS Conventional Orbis Optical Smoke Detector The Orbis Optical Smoke Detector works using the well established light scatter principle, however, the sensing technology is radically different in design from previous optical detectors and significantly reduces false alarms. • • • • • • Responds well to slow-burning, smouldering fires Performs well in black and white smoke Extra confirmation of smoke before alarm signal is given Reduced incidence of false alarms Sensing chamber keeps out dust and other airborne contaminants Operates over a broad range of voltages at extremes of temperature Operating voltage Quiescent current Alarm current Remote output Size Operating temperature Relative humidity IP rating Weight 8.5 to 33 VDC 65μA at 24 VDC 40mA at 24 VDC 1.2kΩ to -ve supply 97Dia x 31H mm -40°C to +70°C (no icing) 0 to 98% (non condensing) IP23D (EN60529) 75 grams Orbis Optical Smoke Detector ORB-OP-12001-AMP Approvals: EN54-7/LPCB Orbis Multisensor Detector The Orbis Multisensor Detector benefits from the same false alarm reduction technology as the optical detector. It is a thermally enhanced smoke detector and so will not give an alarm from heat alone. • • • • • Responds well to fast-burning, flaming fires Reduced incidence of false alarms Increased reliability of detection Sensing chamber keeps out dust and other airborne contaminants Operates over a broad range of voltages at extremes of temperature CONTACT AMPAC 8.5 to 33 VDC 65μA at 24 VDC 40mA at 24 VDC 1.2kΩ to -ve supply 97Dia x 42H mm -40°C to +70°C (no icing) 0 to 98% (non condensing) IP23D (EN60529) 80 grams Orbis Multisensor Detector Approvals: EN54-7/LPCB SEA/PAGE 24 Operating voltage Quiescent current Alarm current Remote output Size Operating temperature Relative humidity IP rating Weight HOME CONTENTS SEARCH ZOOM ORB-OH-13001-AMP PRINT EXIT DETECTORS ORBIS Conventional Orbis Heat Detector The Orbis Heat Detector monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. There are seven classes of heat detectors in the Orbis range designed to suit a wide variety of operating conditions. • • • • Can be used for applications where smoke detectors are unsuitable Ideal in environments that are dirty or smokey under normal conditions Reduced incidence of false alarms Increased reliability of detection 8.5 to 33 VDC 65μA at 24 VDC 40mA at 24 VDC 1.2kΩ to -ve supply 97Dia x 36H mm -40°C to +70°C (no icing) 0 to 98% (non condensing) IP23D (EN60529) 70 grams Orbis Heat Detector A1R Standard 50°C MAT Rate-of-Rise A1S Standard 50°C MAT Static A2S Standard 50°C MAT Static BR Standard 65°C MAT Rate-of-Rise BS Standard 65°C MAT Static CR Standard 80°C MAT Rate-of-Rise CS Standard 80°C MAT Static Approvals: EN54-5/LPCB MAT Operating voltage Quiescent current Alarm current Remote output Size Operating temperature Relative humidity IP rating Weight Maximum Application Temperature ORB-HT-11001-AMP ORB-HT-11166-AMP ORB-HT-11002-AMP ORB-HT-11003-AMP ORB-HT-11004-AMP ORB-HT-11005-AMP ORB-HT-11006-AMP TimeSaver Base The TimeSaver Base is a completely new design that provides installers with an open working area with fixing holes shaped to allow a simple mounting procedure. • • • • • Grouped terminals to make wiring easy Two fixing centres LED alignment mark Cable stripping guide Detector locking mechanism 100Dia x 8H mm IP23D (EN60529) 60 grams Size IP rating Weight TimeSaver Base ORB-MB-00012-AMP Approvals: EN54/LPCB SEA/PAGE 25 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS ORBIS Conventional TimeSaver Diode Base The TimeSaver Diode Base has the same design as the standard TimeSaver Base with the addition of a diode. It is used in systems which house active EOL monitoring for head removal. • Grouped terminals to make wiring easy • Two fixing centres • LED alignment mark • Cable stripping guide • Continuity link for voltage testing of zone wiring prior to commissioning • Detector locking mechanism • Other devices continue to work during unauthorised removal of detectors Size IP rating Weight 100Dia x 8H mm IP23D (EN60529) 60 grams TimeSaver Diode Base ORB-DB-00003-AMP Approvals: EN54/LPCB TimeSaver Relay Base The TimeSaver Relay Base incorporates a single pole voltage-free changeover contact for switching external equipment. When the detector changes to the alarm state, the relay is energised, causing the contact to change state. The contact will remain in this condition until the detector is reset. • • • • • • • Grouped terminals to make wiring easy Two fixing centres LED alignment mark Cable stripping guide Continuity link for voltage testing of zone wiring prior to commissioning Detector locking mechanism Capable of switching up to 30V at 1A Size Operating temperature Humidity IP rating Weight 100Dia x 8H mm -40°C to +70°C 0 to 98% IP23D (EN60529) 60 grams TimeSaver Relay Base ORB-RB-10004-AMP Approvals: EN54/LPCB SEA/PAGE 26 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS DS Series Intelligent Detectors The DS Series of intelligent fire detectors is advanced in design, improved in performance and has unique features that benefit the installer and end user. The range features standard, isolator and relay bases.The DS Series has a ‘central intelligence’ system where all the decisions are made by the control panel. Features • DIL Switch Addressing • Alarm Flag for fast alarm reporting • Alarm Address for fast location of alarm • Electronics-free base • Easy installation • Elegant design • Insect Resistant SEA/PAGE 27 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS DS Series DS Optical Smoke Detector The DS Series Photo Detector continuously monitors the environment for contamination of clean air by smoke particles. This facilitates early warning of incipient fires. • • • • • • • • Detects a wide range of fires Insensitive to wind Transient voltage protection Fine gauze insect protection Simple construction allows detection chamber to be cleaned Lockable security fitting White Finish DIL switch address setting Approvals: EN54/LPCB Operating voltage Quiescent current Alarm current Remote output Size Operating temperature Relative humidity IP rating Weight 17-28 VDC 340μA at 24 VDC 2.5mA at 24 VDC N/A 100Dia x 50H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) IP43 157 grams DS Optical Smoke Detector 55000-665AMP DS Heat Detector The DS Series Heat Detector monitors temperature by using a single thermistor network that provides a voltage output proportional to the external air temperature. • Rate of rise and fixed temperature alarm point • Single thermistor technology • Transient voltage protection • Resettable operation • Lockable security finish • White finish • DIL switch address setting Operating voltage Quiescent current Alarm current Remote output Size Operating temperature Relative humidity IP rating Weight 17-28 VDC 300μA at 24 VDC 2.5mA at 24 VDC N/A 100Dia x 50H mm -20°C to +70°C (no icing) 0 to 95% (non condensing) IP53 157 grams DS Heat Detector Standard (55°C) DS Heat Detector High Temperature (90°C) 55000-465AMP 55000-475AMP Approvals: EN54/LPCB SEA/PAGE 28 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS DS Series Standard Base All detectors in the DS Series fit the Standard Base. It is a low insertion force base with stainless steel contacts for the detector terminals. • One way fit of detector • Locking feature to prevent unauthorised removal Size Operating temperature Relative humidity Weight 100Dia x 8H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) 55 grams Approvals: EN54-5, 7 & 8/LPCB Standard Base 45681-200AMP Deep Base The DeepBase is a mounting base for the DS Series Products which has an increased depth to allow for cables to be inserted into the side. • One way fit of detector • Locking feature to prevent unauthorised removal Size Operating temperature Relative humidity Weight 100Dia x 17H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) 55 grams Approvals: EN54-5, 7 & 8/LPCB DS Deep Base SEA/PAGE 29 CONTACT AMPAC HOME CONTENTS SEARCH 45681-213AMP ZOOM PRINT EXIT DETECTORS DS Series Relay Base The Low Power Relay Base incorporates a low power relay to control field equipment such as automatic door closers. • • • Gives a set of voltage free contacts controlled by the remote output of a detector Draws negligible current Capable of switching up to 30V at 1A Voltage Quiescent current Size Operating temperature Relative humidity Weight 17-28 VDC 5mA at 24 VDC 100Dia x 17H mm -20°C to +70°C (no icing) 0 to 95% (non condensing) 100 grams DS Relay Base 45681-504AMP Isolating Base The new style Isolating Base senses and detects short-circuit faults on the Addressabe Detection loops and spurs. • Up to 20 devices may be installed between isolating bases • High brightness LED Voltage Quiescent current Size Operating temperature Relative humidity Weight 17-28 VDC 47μA (non isolating) 4mA (isolating) 100Dia x 17H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) 100 grams DS Isolating Base SEA/PAGE 30 CONTACT AMPAC HOME CONTENTS SEARCH 45681-505AMP ZOOM PRINT EXIT DETECTORS XP95 Intelligent Detectors The XP95 range of intelligent fire detectors is advanced in design, improved in performance and has unique features that benefit the installer and end user. The range features smoke detectors (ionisation and optical), standard and high temperature heat detectors and a multisensor. Beam detectors, flame detectors, manual call points, audio visual signalling devices, interface units and isolators complete the range. XP95 has a ‘central intelligence’ system where all the decisions are made by the control panel. Features • Alarm Flag for fast alarm reporting • Alarm Address for fast location of alarm • XPERT card addressing • Electronics-free base • Easy installation • Elegant design • Insect Resistant SEA/PAGE 31 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS APOLLO XP95 Intelligent XP95 Ionisation Smoke Detector The XP95 Ionisation Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm. • • • • Responds well to fast-burning, flaming fires Designed to operate in a variety of environments Minimal effects from temperature, humidity, atmospheric pressure Well protected against electromagnetic interference over a wide frequency range Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base 17-28 VDC 280μA at 24 VDC 2.0mA at 24 VDC 100Dia x 50H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) IP23D 161 grams XP95 Ionisation Smoke Detector 55000-520-AMP Approvals: EN54-7/LPCB XP95 Optical Smoke Detector The XP95 Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely. • Responds well to slow-burning, smouldering fires • Well suited for bedrooms and escape routes • Unaffected by wind or atmospheric pressure Approvals: EN54-7/LPCB Voltage 17-28 VDC Quiescent current 340μA at 24 VDC Alarm current 4mA at 24 VDC Size inc base 100Dia x 50H mm -20°C to +60°C (no icing) Operating temperature Relative humidity 0 to 95% (non condensing) IP rating IP23D Weight inc base 157 grams Sensitivity0.12db/m XP95 Optical Smoke Detector SEA/PAGE 32 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 55000-620-AMP PRINT EXIT DETECTORS APOLLO XP95 Intelligent XP95 Heat Detector The XP95 Heat Detector monitors temperature by using a single thermistor network which provides a count output proportional to the external air temperature. The XP95 range features two Heat Detectors, standard and high emperature. The standard heat detector is classified as an A2S device and will report an alarm at 55°C. The high temperature detector, classified as a CS device, will report an alarm at 90°C. • Ideal in environments that are dirty or smoky under normal conditions • Well suited for warehouses, loading bays and car parks • Unaffected by wind or atmospheric pressure Approvals: EN54-5/LPCB Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base 17-28 VDC 250-270μA at 24 VDC 2mA at 24 VDC 100Dia x 50H mm A2S: -20°C to +70°C (no icing) CS: -20°C to +120°C (no icing) 0 to 95% (non condensing) IP53 157 grams XP95 Heat Detector Standard – A2S XP95 Heat Detector High Temperature – CS 55000-420-AMP 55000-401-AMP XP95 Multisensor Detector The XP95 Multisensor Detector contains an optical smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analogue value. • Sensitive to a wide range of fires • Well suited for environments such as hotel bedrooms • Unaffected by wind or atmospheric pressure Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base 17-28 VDC 500μA at 24 VDC 3.5mA at 24 VDC 100Dia x 58H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) IP53 160 grams XP95 Multisensor Detector SEA/PAGE 33 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 55000-885-AMP PRINT EXIT DETECTORS APOLLO XP95 Intelligent XP95 Intelligent Detector Base All detectors in the XP95 range fit the Intelligent Detector Base. It is a low insertion force base with stainless steel contacts for the detector terminals. • XPERT addressing • One way fit of detector • Locking feature to prevent unauthorised removal Size Operating temperature Relative humidity Weight 100Dia x 8H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) 55 grams XP95 Intelligent Detector Base 45681-210-AMP Approvals: EN54-5, 7 & 8/LPCB XP95 Isolating Base The new style Isolating Base senses and detects short-circuit faults on XP95 loops and spurs. • Up to 20 devices may be installed between isolating bases • High brightness LED 17-28 VDC 47μA (non isolating) 4mA (isolating) 100Dia x 24H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) 100 grams Voltage Quiescent current Size Operating temperature Relative humidity Weight XP95 Isolating Base 45681-284-AMP XP95 Intelligent Low Power Relay Base The Low Power Relay Base incorporates a low power relay to control field equipment such as automatic door closers. • • • Gives a set of voltage free contacts controlled by the remote output of a detector Draws negligible current Capable of switching up to 30V at 1A Voltage Quiescent current Size Operating temperature Relative humidity Weight 17-28 VDC 5mA at 24 VDC 100Dia x 24H mm -20°C to +70°C (no icing) 0 to 95% (non condensing) 100 grams XP95 Intelligent Low Power Relay Base SEA/PAGE 34 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 45681-242-AMP EXIT DETECTORS APOLLO XP95 Intelligent Blank XPERT Card Pre-addressed XPERT Card A universal address card supplied with all bases. Using a coding guide, pips are removed to set the address of the inserted detector. Pre-addressed XPERT cards are supplied with pips already removed. • • • • Simplifies and speeds up installation and commissioning Uses patented, proven technology Address remains the same, no matter how often detectors are replaced Flexibility to create any address z Saves time and increases accuracy during commissioning z Pre-numbered 1-126 Blank XPERT Card Pre-addressed XPERT Card 1-126 38531-771-AMP 45682-127-AMP XP95 Manual Call Point The XP95 Manual Call Point is compliant with EN54-11. The address of each call point is set at the commissioning stage by means of a seven segment DIL switch. The device features plug and play terminal connections and a resettable element. • • • • • Plug-and-play terminal connectors for fast wiring Allows wiring continuity testing before fitting Isolated version available Reports an alarm in under 0.2 seconds Resettable element CONTACT AMPAC HOME 17-28 VDC 100μA at 24VDC 4mA 7 segment DIL switch 93H x 89W x 59.5D mm -20°C to +60°C (no icing) 0-95% (non condensing) IP45 190 grams XP95 Manual Call Point (Surface) XP95 Manual Call Point with Isolator (Surface) Approvals: EN54-11/LPCB EN54-17/LPCB (Isolated Version) SEA/PAGE 35 Voltage Quiescent current Alarm current Address method Size (surface mount) Operating temperature Relative humidity IP rating Weight CONTENTS SEARCH ZOOM PRINT 55100-905-AMP 55100-908-AMP EXIT DETECTORS APOLLO XP95 Intelligent Intelligent Waterproof Manual Call Point The Intelligent Waterproof Manual Call Point has been designed for use outdoors and in places where moisture can occur. • • • • Plug and play terminal connections for fast wiring Allow wiring continuity testing before fitting Isolated version available Resettable element Approvals: EN54-11/LPCB EN54-17/LPCB (Isolated Version) Voltage Quiescent current Alarm current Address method Size (surface mount) Operating temperature Relative humidity IP rating Weight 17-28 VDC 230μA 2mA 7 segment DIL switch 87H x 87W x 54D mm -20°C to +70°C (no icing) 0-95% (non condensing) IP67 400 grams Intelligent Waterproof Manual Call Point Intelligent Waterproof Manual Call Point with Isolator 58100-950-AMP 58100-951-AMP XP95 Intelligent Reflective Beam Detector The XP95 Reflective Beam Detector differs from a traditional beam detector in that it is a single unit which houses a transmitter, a receiver and the control electronics. The beam detector is available in two versions: a single reflector model for distances of 5-50m and a four-reflector unit for distances of 50-100m. • • • • • SEA/PAGE 36 Loop-powered, requires no external supply Compatible with Discovery and XP95 protocols Incorporates a short-circuit isolator Automatic drift compensation Automatic reset following alarm or fault condition CONTACT AMPAC HOME Input voltage Quiescent current Alarm current Dimensions Operating temperature Relative humidity IP rating Weight Min beam distance Max beam distance 17-28 VDC 5μA @ 24 VDC 9mA at 24 VDC 210H x 150W x 120D mm -20°C to +55 °C (no icing) 0-95% (non condensing) IP50 670 grams 5 metres 100 metres Reflective Beam Detector 5-50m Reflective Beam Detector 50-100m Beam Detector Reflector 100mm x 100mm Termination Back Box CONTENTS SEARCH ZOOM PRINT 55000-268-AMP 55000-273-AMP 29600-201-AMP 29600-241-AMP EXIT DETECTORS Discovery Intelligent Detectors Discovery is a range of high-specification, intelligent fire detectors developed to meet the requirements of sophisticated systems while providing engineers with an additional dimension in fire protection capability. Discovery has a ‘distributed intelligence system’ where decisions are made in the detector head as well as at the control panel. Drift compensation is also incorporated into the detector, allowing it to adapt to dirty or dusty environments reducing false alarms. • Rejection of transient signals • Flashing LED option • Five response modes for ease of optimisation to changing environments • Drift compensation to ensure constant sensitivity • Four bytes of non-volatile memory for user data • Alarm flag for fast alarm reporting • Conventional alarm facility during control panel processor fault • 360° visibility in alarm • Compatible with XP95 systems • Insect resistant SEA/PAGE 37 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS APOLLO DISCOVERY Intelligent Discovery Ionisation Smoke Detector The Discovery Ionisation Smoke Detector uses a low activity radioactive foil to irradiate the air in the smoke chamber causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm. • Responds well to fast-burning, flaming fires • Designed to operate in a variety of environments • Remote test feature Approvals: EN54-7/LPCB Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base 17-28 VDC 500μA at 24 VDC 3.5mA at 24 VDC 100Dia x 50H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) IP43 160 grams Discovery Ionisation Smoke Detector 58000-500-AMP Discovery Optical Smoke Detector The Discovery Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely. • • • • Responds well to slow-burning, smouldering fires Well suited for bedrooms and escape routes Unaffected by wind or atmospheric pressure Remote test feature Approvals: EN54-7/LPCB SEA/PAGE 38 CONTACT AMPAC Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base 17-28 VDC 400μA at 24 VDC 3.5mA at 24 VDC 100Dia x 50H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) IP43 160 grams Discovery Optical Smoke Detector HOME CONTENTS SEARCH ZOOM 58000-600-AMP PRINT EXIT DETECTORS APOLLO DISCOVERY Intelligent Discovery Heat Detector The Discovery Heat Detector, distinguishable by the low airflow resistant case, uses a single thermistor to sense the air temperature around the detector. • • • • Ideal in environments that are dirty or smokey under normal conditions Well suited for warehouses, loading bays and car parks Unaffected by wind or atmospheric pressure Remote test feature Approvals: EN54-5/LPCB Heat Detector Response Modes Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base 17-28 VDC 500μA at 24 VDC 3.4mA at 24 VDC 100Dia x 50H mm 0°C to +80°C (no icing) 0 to 95% (non condensing) IP53 160 grams Discovery Heat Detector Mode 58000-400-AMP ClassApplication (EN54-5:2000)Temperature °C 1 A1R 2 A2 3 A2S 4 CR 5 CS Typ Max 2550 2550 2550 5580 5580 Static Response Temperature °C Min 54 54 54 84 84 Typ 57 61 61 90 90 For air temperatures in the range 15°C to 55°C, the analogue value for a detector in mode 1 will correspond approximately to the air temperature. SEA/PAGE 39 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT Max 65 70 70 100 100 DETECTORS APOLLO DISCOVERY Intelligent Discovery Multisensor Detector The Discovery Multisensor Detector comprises optical smoke and thermistor temperature sensors whose outputs are combined to give the final analogue value. As a result, the multisensor is useful over a wide range of applications and is highly immune to false alarms. • • • • • • • Ideal for a wide range of applications Highly immune to false alarms Well suited for environments such as hotel bedrooms Unaffected by wind or atmospheric pressure Well suited for sensitive environments Heat only, optical only options Remote test feature Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base 17-28 VDC 500μA at 24 VDC 3.5mA at 24 VDC 100Dia x 58H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) IP43 160 grams Discovery Multisensor Detector 58000-700-AMP Approvals: EN54-5/LPCB EN54-7/LPCB Multisensor Detector Operating Modes SEA/PAGE 40 CONTACT AMPAC Mode Smoke Sensitivity (grey smoke) 1 2 3 4 5 HOME % per m % per ft 1.1 0.35 2.1 0.7 2.80.9 4.21.4 No response to smoke CONTENTS Temperature Sensitivity Response Type (relative) High No response to heat Low High See text SEARCH Minimum Time to Alarm (seconds) Multisensor Optical Multisensor Multisensor Heat A1 ZOOM PRINT 20 30 20 20 30 EXIT DETECTORS APOLLO DISCOVERY Intelligent Discovery Carbon Monoxide Detector The Discovery Carbon Monoxide (CO) Detector is good at detecting deepseated fires. Please note that CO detectors do not detect smoke particles or heat and are not universal replacements for smoke detectors. • • • • • Enhanced detection capability Early response to hot fires Ideal for smouldering fires Less susceptible to false alarms caused by steam than smoke alarms Five response modes Voltage Quiescent current Alarm current Size inc base Operating temperature Relative humidity IP rating Weight inc base Cell life (max) 17-28 VDC 500μA at 24 VDC 3.5mA at 24 VDC 100Dia x 50H mm 0°C to +50°C (no icing) 15 to 95% (non condensing) IP43 160 grams 7 years Discovery Carbon Monoxide Detector Mode Relative Performance of Detectors in Test Fires SEA/PAGE 41 CONTACT AMPAC Alarm Threshold (ppm) Minimum Time to Alarm (seconds) 30 60 1 58000-300-AMP Typical Application Sleeping with no ambient CO 2 45 30 General use fast response such as supplementary protection in atria 3 45 60 General use and sleeping risk with some low-level CO (such as from light smoking or an unventilated gas fire) 4 60 30 General smoking area and supplementary detection of deep seated fires such as laundry rooms Supplementary use in kitchen or boiler room 5 75 HOME 30 CONTENTS SEARCH ZOOM PRINT EXIT DETECTORS APOLLO DISCOVERY Intelligent Discovery Intelligent Detector Base All detectors in the Discovery range fit the Intelligent Detector Base. It is a low insertion force base with stainless steel contacts for the detector terminals. XPERT cards are supplied with all bases. • XPERT addressing • One way fit • Locking feature to prevent unauthorised removal Size Operating temperature Relative humidity Weight 100Dia x 8H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) 55 grams Discovery Intelligent Detector Base 45681-210-AMP Approvals: EN54-5/LPCB EN54-7/LPCB EN54-8/LPCB Discovery Isolating Base The new style Isolating Base senses and detects short-circuit faults on loops and spurs. • Up to 20 devices may be installed between isolating bases • High brightness LED Voltage Quiescent current Size Operating temperature Relative humidity Weight 17-28 VDC 47μA (non isolating) 4mA (isolating) 100Dia x 24H mm -20°C to +60°C (no icing) 0 to 95% (non condensing) 100 grams Discovery Isolating Base SEA/PAGE 42 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 45681-284-AMP PRINT EXIT DETECTORS APOLLO DISCOVERY Intelligent Discovery Intelligent Low Power Relay Base The Intelligent Low Power Relay Base incorporates a low power relay to control field equipment such as automatic door closers. • • • 17-28 VDC 5mA at 24 VDC 100Dia x 24H mm -20°C to +70°C (no icing) 0 to 95% (non condensing) 100 grams Discovery Intelligent Low Power Relay Base 45681-242-AMP Blank XPERT Card Pre-addressed XPERT Card A universal address card supplied with all bases. Using a coding guide, pips are removed to set the address of the inserted detector. Pre-addressed XPERT cards are supplied with PIPs already removed. • • • • SEA/PAGE 43 Gives a set of voltage free contacts controlled by the remote output of a detector Draws negligible current Capable of switching up to 30V at 1A Voltage Quiescent current Size Operating temperature Relative humidity Weight Simplifies and speeds up installation and commissioning Uses patented, proven technology Address remains the same, no matter how often detectors are replaced Flexibility to create any address CONTACT AMPAC HOME CONTENTS z Saves time and increases accuracy during commissioning z Pre-numbered 1-126 Blank XPERT Card Pre-addressed XPERT Card 1-126 SEARCH ZOOM 38531-771-AMP 45682-127-AMP PRINT EXIT DETECTORS APOLLO DISCOVERY Intelligent Discovery Manual Call Point The Discovery Manual Call Point is compliant with EN54-11. The address of each call point is set at the commissioning stage by means of a seven segment DIL switch. The device features plug and play terminal connections and a resettable element. • • • • • Plug-and-play terminal connectors for fast wiring Allows wiring continuity testing before fitting Isolated version available Reports an alarm in under 0.2 seconds Resettable element Voltage Quiescent current Alarm current Address method Size (surface mount) Operating temperature Humidity IP rating Weight 17-28 VDC 100uA 4mA 7 segment DIL switch 87H x 87W x 52D mm -20°C to +60°C (no icing) 0-95% (non condensing) IP53 190 grams Discovery Manual Call Point with Isolator (Surface) Discovery Manual Call Point (Surface) Approvals: EN54-11/LPCB EN54-17/LPCB (Isolated Version) 58100-908-AMP 58100-910-AMP Discovery Waterproof Manual Call Point The Discovery Waterproof Manual Call Point has been designed for use outdoors and in places where moisture can occur. It can be used with the XP95 and Discovery ranges. • • • • Plug and play terminal connections for fast wiring Allow wiring continuity testing before fitting Isolated version available Resettable element Approvals: EN54-11/LPCB EN54-17/LPCB (Isolated Version) SEA/PAGE 44 CONTACT AMPAC HOME Voltage Quiescent current Alarm current Address method Size (surface mount) Operating temperature Humidity IP rating Weight 17-28 VDC 100uA 4mA 7 segment DIL switch 93H x 97.5W x 71D mm -30°C to +70°C (no icing) 0-95% (non condesing) IP67 240 grams Discovery Waterproof Manual Call Point Discovery Waterproof Manual Call Point with Isolator CONTENTS SEARCH ZOOM PRINT 58100-950-AMP 58100-951-AMP EXIT INTERFACES XP95/Discovery Intelligent Interfaces Apollo manufactures a comprehensive range of interfaces for intelligent systems which enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. There are a variety of interfaces available to suit a number of individual applications. Standard Interfaces with Isolators are fitted with bi-directional short-circuit isolators so that they are unaffected by a single short circuit on either loop input or output. However, the Input/Output Unit and Output Unit with isolator are exceptions to this. The removal of loop power to these interfaces will cause a ‘set’ relay to ‘reset’. DIN-Rail Interfaces feature enclosures that clip to standard 35mm DIN-Rails or are screwed to the base of a larger enclosure. They enable fire system designers to determine the functions required and create multi-purpose interfaces for individual sites. • Easy to install • Well protected • Modular design • A neat solution SEA/PAGE 45 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT INTERFACES XP95/DISCOVERY Intelligent Input/Output Unit with Isolator The Input/Output unit with Isolator provides a voltage free, single, pole, change-over relay output, a single, monitored switch input and an unmonitored, non-polarised opto-coupled input. • • • • • • It can report fault, switch open and switch closed levels Three visible LEDs Loop powered Voltage free Capable of switching up to 1A at 30V Built-in short circuit isolator Approvals: EN54-18/LPCB Voltage17-28vdc 1.2mA at 24vdc Quiescent current Max current 3.5mA at 24vdc Relay contact 1A at 30vdc Opto input 35vdc max Monitored input voltage 9-11vdc -20°C to +70°C (no icing) Operating temperature Relative humidity 0 to 95% (non condensing) IP Rating IP54 Size 150W x 90H x 48D mm Weight 240 grams Input/Output Unit with Isolator 55000-847-AMP Output Unit with Isolator The Output Unit with Isolator provides two voltage free single pole, change-over relay outputs. It is a simplified version of the Input/Output unit without circuitry for monitoring inputs. • Capable of switching up to 1A at 30V • Loop powered • Built-in short circuit isolator Approvals: EN54-18/LPCB Voltage17-28vdc Quiescent current 1.2μA at 24vdc 3mA at 24vdc Max current Relay contact 1A at 30vdc Operating temperature -20°C to +70°C (no icing) Relative humidity 0 to 95% (non condensing) IP Rating IP54 150W x 90H x 48D mm Size Weight 240 grams Output Unit with Isolator SEA/PAGE 46 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 55000-849-AMP PRINT EXIT INTERFACES XP95/DISCOVERY Intelligent Switch Monitor with Isolator The Switch Monitor with Isolator is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Ampac compatible analogue control equipment. • • • • Four input states – ’normal’, ’fault’, ’pre-alarm’ and ’alarm’ Two visible LEDs Loop powered Built-in short circuit isolator Approvals: EN54-18/LPCB Voltage Quiescent current Max current Max switching current Monitored input voltage Operating temperature Relative humidity IP Rating Size Weight 17-28 dc 1.25mA at 24vdc 3.6mA at 24vdc 3A at 30vdc 9-11vdc -20°C to +70°C (no icing) 0 to 95% (non condensing) IP54 150W x 90H x 48D mm 240 grams Switch Monitor with Isolator 55000-843-AMP Switch Monitor Plus with Isolator The Switch Monitor Plus with Isolator is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Ampac compatible analogue control equipment. Additional circuitry is incorporated to monitor flow switches and provide a time delay. It can also be used to reset a beam detector. • • • • • Output for resetting a remote detector Four input states – ’normal’, ’fault’, ’pre-alarm’ and ’alarm’ Two visible LEDs Selectable alarm delay for monitoring flow switches – 30 seconds Built-in short circuit isolator Voltage17-28vdc Quiescent current 1.25mA at 2 vdc 4.2mA at 24vdc Max current Max switching current 3A at 30vdc 9-11vdc Monitored input voltage Operating temperature -20°C to +70°C (no icing) Relative humidity 0 to 95% (non condensing) IP54 IP Rating Size 150W x 90H x 48D mm 240 grams Weight Switch Monitor Plus with Isolator 55000-841-AMP Approvals: EN54-18/LPCB SEA/PAGE 47 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT INTERFACES XP95/DISCOVERY Intelligent Zone Monitor with Isolator The Zone Monitor with Isolator powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 Loop. • Loop powered • Visible LED • Built-in short circuit isolator Approvals: EN54-18/LPCB Voltage17-28vdc 4mA + detector load Quiescent current Alarm current 11mA at 24vdc EOL resistor value 5.1k ¹⁄₃ watt Maximum capacitor on zone terminals 50µF Zone voltage 19V ± 1V -20°C to +70°C (no icing) Operating temperature Relative humidity 0 to 95% (non condensing) IP Rating IP54 Size 150W x 90H x 48D mm Weight 230 grams Discovery/XP95 Zone Monitor with Isolator 55000-845-AMP Sounder Control Unit with Isolator The XP95 Sounder Control Unit with Isolator is used to control the operation of a zone of conventional sounders and report their status to the control panel. • Allows sounders to be operated continuously or be pulsed or be pulsed, 1 second on 1 second off • May be synchronized when in pulsed operation Approvals: EN54-18/LPCB Voltage17-28vdc Quiescent current 1.95mA at 24vdc Loop current max 4.5mA External supply 9-32vdc 1.25A 3mA at 32vdc External quiescent current External current max 47mA + load Sounder circuit load max 1A at 30vdc Operating temperature -20°C to +70°C (no icing) Relative humidity 0 to 95% (non condensing) IP54 IP Rating Size 150W x 90H x 48D mm Weight 240 grams Sounder Control Unit with Isolator SEA/PAGE 48 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 55000-852-AMP PRINT EXIT INTERFACES XP95/DISCOVERY Intelligent Three Channel Input/Output Unit with Isolator The Three Channel Input/Output unit with Isolator provides three voltage free, single pole, change-over relay outputs, and three monitored switch inputs. • • • • Supervises one or more normally-open switches on each of the three inputs Loop powered Capable of switching up to 30V at 1A on each of the three outputs Built-in short circuit isolator Approvals: EN54-18/LPCB Voltage17-28vdc 3mA at 24vdc Quiescent current Max current 7.5mA at 24vdc Relay contact 1A at 30vdc Monitored input voltage 9-11vdc Operating temperature -20°C to +70°C (no icing) 0 to 95% (non condensing) Relative humidity IP Rating IP54 Size 250W x 175H x 75D mm Weight 621 grams Three Channel Input/Output Unit with Isolator 55000-588-AMP Mains Switching Input/Output Unit The Mains Switching Input/Output Unit provides a voltage free, single pole, change-over relay output, and three monitored switch input. • Supervises one or more normally-open switches connected to a single pair of cables • Three visible LEDs • Capable of switching 250 vac at up to 5 amps Approvals: EN54-18/LPCB Voltage17-28vdc Quiescent current 3.5mA at 24vdc Rated load 5A at 240vac 2A at 48vdc Switching capacity max 1.25kva Switch input monitoring voltage 9-11vdc Operating temperature -20°C to +70°C (no icing) Relative humidity 0 to 95% (non condensing) IP Rating IP54 Size 150W x 90H x 48D mm Weight 240 grams Mains Switching Input/Output Unit SEA/PAGE 49 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 55000-875APO PRINT EXIT INTERFACES XP95/DISCOVERY Intelligent DIN-Rail Input/Output Unit The DIN-Rail Input/Output Unit provides a voltage free, single pole, change-over relay output, a single monitored switch input and an unmonitored, non-polarised opto-coupled input. • • • • • It can report fault, switch open and switch closed levels Three visible LEDs Loop powered Voltage free Capable of switching up to 30V at 1A Voltage17-28vdc 1.2mA at 24vdc Quiescent current Max current 4.5mA at 24vdc Relay contact 1A at 30vdc Opto input 35vdc max Monitored input voltage 9-11vdc -20°C to +70°C (no icing) Operating temperature Relative humidity 0 to 95% (non condensing) IP Rating IP20 Size 110H x 107W x 20Dmm Weight 95 grams DIN-Rail Input/Output Unit 55000-803-AMP DIN-Rail Output Unit The DIN-Rail Output Unit provides a voltage free single pole, change-over relay output. It is a simplified version of the Input/Output unit without circuitry for monitoring inputs. • Capable of switching up to 30V at 1A Voltage17-28vdc Quiescent current 720µA at 24vdc 3.3mA at 24vdc Max current Relay contact 1A at 30vdc Operating temperature -20°C to +70°C (no icing) Relative humidity 0 to 95% (non condensing) IP Rating IP20 110H x 107W x 20Dmm Size Weight 95 grams DIN-Rail Output Unit SEA/PAGE 50 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 55000-804-AMP PRINT EXIT INTERFACES XP95/DISCOVERY Intelligent DIN-Rail Switch Monitor The DIN-Rail Switch Monitor is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Ampac compatible analogue control equipment. • Four input states – ’normal’, ’fault’, ’pre-alarm’ and ’alarm’ • Two visible LEDs • Loop powered Voltage17-28vdc 730µA at 24vdc Quiescent current Max current 5.6mA at 24vdc Monitored input voltage 9-11vdc Operating temperature -20°C to +70°C (no icing) Relative humidity 0 to 95% (non condensing) IP20 IP Rating Size 110H x 107W x 20Dmm Weight 95 grams DIN-Rail Switch Monitor 55000-822-AMP DIN-Rail Switch Monitor Plus The DIN-Rail Switch Monitor Plus is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Ampac compatible analogue control equipment. It has an output for resetting a remote detector and a selectable alarm delay making it suitable for monitoring flow switches. • • • • • Output for resetting a remote detector Four input states – ’normal’, ’fault’, ’pre-alarm’ and ’alarm’ Two visible LEDs Selectable alarm delay for monitoring flow switches Loop powered Voltage17-28vdc Quiescent current 730µA at 24vdc 5.6mA at 24vdc Max current Opto output voltage 5-30vdc 1mA Opto current Monitored input voltage 9-11vdc Operating temperature -20°C to +70°C (no icing) 0 to 95% (non condensing) Relative humidity IP Rating IP20 110H x 107W x 20Dmm Size Weight 95 grams DIN-Rail Switch Monitor Plus SEA/PAGE 51 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 55000-821-AMP PRINT EXIT INTERFACES XP95/DISCOVERY Intelligent DIN-Rail Zone Monitor with Isolator The DIN-Rail Zone Monitor with Isolator powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 Loop. • Loop powered • Visible short circuit LED • Built-in isolator Voltage17-28vdc 4mA + detector load Quiescent current Max current 11mA at 24vdc Relay contact 30V at 1A clean changeover Zone voltage 19V ± 1V Operating temperature -20°C to +70°C (no icing) 0 to 95% (non condensing) Relative humidity IP Rating IP54 Size 110H x 107W x 20Dmm Weight 95 grams DIN-Rail Zone Monitor with Isolator 55000-812-AMP DIN-Rail Sounder Control Unit (5 Amps) The DIN-Rail Sounder Control Unit (5 Amps) is used to control the operation of a zone of conventional sounders and report their status to the control panel. • Allows sounders to be operated continuously or be pulsed, 1 second on, 1 second off • May be synchronized when in pulsed operation • An auto-coupled input is provided to monitor the state of the external power supply • Sounders can be operated individually or in groups • Will accept a load of 5 amperes Voltage17-28vdc Loop quiescent current 1.9mA at 24vdc Loop max current 4.5mA at 24vdc External supply 9-50vdc External quiescent current 3mA at 32V 47mA + load External max current External max load 5A at 35vdc Operating temperature -20°C to +70°C (no icing) Relative humidity 0 to 95% (non condensing) IP Rating IP20 110H x 107W x 20Dmm Size Weight 95 grams DIN-Rail Sounder Control Unit SEA/PAGE 52 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 55000-182-AMP PRINT EXIT INTERFACES XP95/DISCOVERY Intelligent DIN-Rail Dual Isolator The DIN-Rail Dual Isolator provides two independent Isolators which sense and isolate short circuits on Discovery or XP95 loops and spurs. • • • • Loop powered Polarity sensitive Up to 20 detectors can be installed between isolators Allows fully isolated spurs Voltage17-28vdc 47µA at 24vdc Quiescent current Operating temperature -20°C to +60°C (no icing) Relative humidity 0 to 95% (non condensing) IP Rating IP20 Size 110H x 107W x 20Dmm 90 grams Weight DIN-Rail Dual Isolator 55000-802-AMP Mini Switch Monitor The Mini Switch Monitor is an interface within a housing that allows the unit to be fitted onto standard DIN-Rail with a twist-click motion. It monitors the state of one or more single pole volt-free contacts on a single pair of cables. • • • • • SEA/PAGE 53 Mini Switch Monitor Designed for use where space is limited Three status LEDs Built-in isolator Interrupt/non-interrupt Pre-alarm status CONTACT AMPAC HOME Voltage17-28vdc Size 39W x 39H x 20D mm 30 grams Weight CONTENTS SEARCH ZOOM 55000-760-AMP PRINT EXIT INTERFACES XP95/DISCOVERY Intelligent DIN-Rail Interface Enclosures DIN-Rail Interface Enclosures are available in two sizes and can be used for housing intrinsically safe (IS) barriers or DIN-Rail mounted interfaces. • Allows multiple interfaces to be housed together • IP67 SEA/PAGE 54 CONTACT AMPAC HOME DIN-Rail Interface Enclosure – 4 interfaces DIN-Rail Interface Enclosure – 10 interfaces CONTENTS SEARCH ZOOM PRINT 29600-239-AMP 29600-240-AMP EXIT INTERFACES AMPAC INPUT/OUTPUT DEVICES Intelligent Single Input Device (SID) The Single Input Device is an addressable loop device for use on the Apollo XP95 or Discovery protocol and provides a single monitored input. •Interfaces a switch input to an Apollo addressable loop • Loop powered • One monitored input • Only one address used • Enclosure or DIN-Rail chassis mount • Status indicators can be switched on and off Voltage Quiescent current Max current Monitored input Size – enclosure Size – DIN chassis Operating temperature Humidity IP rating – enclosure Weight – enclosure Weight – DIN chassis 17-28 VDC 1.82mA at 24 VDC 2.37mA at 24 VDC 20k normal 500 - 15k closed 132H x 82W x 55D mm 77H x 57W x 40D mm -20°C to +60°C (no icing) 0 to 95% relative humidity IP55 155 grams 75 grams Single Input Device (SID) – Boxed Single Input Device (SID) – DIN mount 201-0300 201-0350 Single Input/Output Device (SIOD) The Single Input/Output Device is an addressable loop device for use on the Apollo XP95 or Discovery protocol and provides a single monitored input and a voltage free relay output. •Interfaces a switch input and a relay output to addressable loop • Loop powered • One monitored input • Single relay with clean changeover contact • Only one address used • Enclosure or DIN-Rail chassis mount • Status indicators can be switched on and off Voltage Quiescent current Max current Relay contact rating Monitored input Size – enclosure Size – DIN chassis Operating temperature Humidity IP rating – enclosure Weight – enclosure Weight – DIN chassis 17-28 VDC 1.74mA at 24 VDC 6.84mA at 24 VDC 1A at 24 VDC clean changeover 20k normal 500 - 15k closed 132H x 82W x 55D mm 77H x 57W x 40D mm -20°C to +60°C (no icing) 0 to 95% relative humidity IP55 155 grams 75 grams Single Input/Output Device (SIOD) – Boxed Single Input/Output Device (SIOD) – DIN mount SEA/PAGE 55 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 201-0301 201-0351 EXIT INTERFACES AMPAC INPUT/OUTPUT DEVICES Intelligent Three Input Device (3ID) The Three Input Device is a versatile loop-powered three monitored input unit device for use on the Apollo XP95 or Discovery protocol. •Interfaces three switch inputs to addressable loop • Loop powered • Three monitored inputs • Only one address used • Enclosure or DIN-Rail chassis mount • Status indicators can be switched on and off Voltage Quiescent current Max current Monitored input Size – enclosure Size – DIN chassis Operating temperature Humidity IP rating – enclosure Weight – enclosure Weight – DIN chassis 17-28 VDC 1.45mA at 24 VDC 3.54mA at 24 VDC 20k normal 500 - 15k closed 200H x 150W x 60D mm 98H x 72W x 40D mm -20°C to +60°C (no icing) 0 to 95% relative humidity IP41 500 grams 125 grams Three Input Device (3ID) – Boxed Three Input Device (3ID) – DIN mount 201-0308 201-0358 Three Input/Output Device (3IOD) The Three Input/Output Device is a versatile loop-powered unit for use on the Apollo XP95 or Discovery protocol. It provides three monitored inputs and three voltage free relay outputs. •Interfaces three switch inputs and three relay outputs to addressable loop • Loop powered • Three fault monitored input • Three relays with clean changeover contact • Only one address used • Enclosure or DIN-Rail chassis mount • Status indicators can be switched on and off Voltage Quiescent current Max current Relay contact rating Monitored input Size – enclosure Size – DIN chassis Operating temperature Humidity IP rating – enclosure Weight – enclosure Weight – DIN chassis 17-28 VDC 2.06mA at 24 VDC 19.23mA at 24 VDC 1A at 24 VDC clean changeover 20k normal 500 - 15k closed 200H x 150W x 60D mm 98H x 72W x 40D mm -20°C to +60°C (no icing) 0 to 95% relative humidity IP41 500 grams 125 grams Three Input/Output Device (3IOD) – Boxed Three Input/Output Device (3IOD) – DIN mount SEA/PAGE 56 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 201-0309 201-0359 EXIT INTERFACES AMPAC INPUT/OUTPUT DEVICES Intelligent Three Input/Output Device (3IOD) EP The Three Input/Output Device EP is an externally powered unit device for use on the Apollo XP95 or Discovery protocol. Using an external 24VDC power supply, each device draws a minimum amount of loop current and provides three monitored inputs and three voltage free relay outputs. •Interfaces three switch inputs and three relay outputs to addressable loop • Externally powered • Three fault monitored input • Three relays with clean changeover contact • Only one address used • Enclosure or DIN-Rail chassis mount • Status indicators can be switched on or off Voltage Quiescent current – loop Quiescent current – external Max current – loop Max current – external Relay contact rating Monitored input Size – enclosure Size – DIN chassis Operating temperature Humidity IP rating – enclosure Weight – enclosure Weight – DIN chassis 17-28 VDC 1.51mA at 24 VDC 5.08mA at 24 VDC 7.20mA at 24 VDC 19.55mA at 24 VDC 1A at 24 VDC clean changeover 20k normal 500 - 15k closed 200H x 150W x 60D mm 98H x 72W x 40D mm -20°C to +60°C (no icing) 0 to 95% relative humidity IP41 500 grams 125 grams Three Input/Output Device (3IOD) EP – Boxed Three Input/Output Device (3IOD) EP – DIN mount SEA/PAGE 57 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 201-0310 201-0360 EXIT WIRELESS TECHNOLOGY NEW XPander Wireless Technology Traditionally, fire detection systems in industrial and commercial applications have used hard wired installations. These systems are generally installed at the time of construction or refurbishment, making the laying of cables not a great issue. However, ceratin applications do not lend themselves to this approach, such as occupied buildings, heritage sites, architecturally sensitive buildings and annexes. This is where wireless systems provide the ideal solution. Xpander is a system in which individual detectors, call points and alarm devices communicate with the XP95 loop by radio signals. An interface is connected to the loop in the same way as any other interface, such as an input/output unit. The Xpander range benefits from the patented XPERT technology that is used in Discovery and XP95. • Easy to install • XPERT card addressing • Self-monitoring • Proven technology • No special control panel needed • 868MHz radio channels • Up to 15 devices per interface • Up to 5 interfaces per loop All detectors within the Xpander range are supplied complete with mounting bases. SEA/PAGE 58 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT WIRELESS TECHNOLOGY APOLLO XPANDER DETECTORS NEW Xpander Optical Smoke Detector and Mounting Base The Xpander Optical Smoke Detector works on the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely. • Responds well to slow-burning, smouldering fires • Well suited for bedrooms and escape routes • Modified to function with the low current requirements of radio systems • Bi-directional (monitored) radio platform • Easy to install • Powered by two independent packs of AA alkaline batteries with a typical three year life Voltage (regulated from radio base) Size inc base Operating temperature Relative humidity IP rating Weight inc base 3VDC 100Dia x 75H mm -10°C to +50°C (no icing) 0 to 95% (non condensing) IP23D 500 grams Xpander Optical Smoke Detector and Mounting Base XPA-CB-12034-AMP Approvals: EN54-7/LPCB NEW Xpander Multisensor Detector and Mounting Base The Xpander Multisensor Detector contains an optical smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analogue value. • Sensitive to a wide range of fires • Well suited for environments such as hotel bedrooms • Modified to function with the low current requirements of radio systems • Bi-directional (monitored) radio platform • Easy to install • Powered by two independent packs of AA alkaline batteries with a typical three year life Voltage (regulated from radio base) Size inc base Operating temperature Relative humidity IP rating Weight inc base 3VDC 105Dia x 80H mm -10°C to +50°C (no icing) 0 to 95% (non condensing) IP23D 500 grams Xpander Optical Smoke Detector and Mounting Base Approvals: EN54-7/LPCB SEA/PAGE 59 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT XPA-CB-13032-AMP WIRELESS TECHNOLOGY APOLLO XPANDER DETECTORS / MANUAL CALL POINTS NEW Xpander Heat Detector and Mounting Base There are two heat detectors in the Xpander range designed to suit a wide variety of operating conditions. A static heat detector (CS) which responds only when a fixed temperature has been reached and a rate-of-rise detector (A1R) which has a fixed upper limit, but in addition, measures the rate of increase in temperature. • Can be used in applications where smoke detectors are unsuitable • Ideal environments that are dirty or smokey under normal conditions • CS detectors are ideal for use in environments with rapid temperature fluctuations such as boiler rooms • Modified to function with the low current requirements of radio systems • Bi-directional (monitored) radio platform • Easy to install • Powered by two independent packs of AA alkaline batteries with a typical three year life Voltage (regulated from radio base) Size inc base Operating temperature Relative humidity IP rating Weight inc base 3VDC 105Dia x 80H mm -10°C to +50°C (no icing) 0 to 95% (non condensing) IP23D 400 grams Xpander Heat Detector and Mounting Base Rate-of-Rise (A1R) Static (CS) XPA-CB-11170-AMP XPA-CB-11171-AMP Approvals: EN54-5/LPCB NEW Xpander Manual Call Point The XPander Manual Call Point is compliant with EN54:11. It is wireless and is powered by two independent packs of AA alkaline batteries with a typical three year life. • Uses patented XPERT addressing • Resettable element • Reports an alarm in under one second Voltage (regulated from radio base) Size inc back box Operating temperature Relative humidity Weight inc base 3VDC 89H x 93W x 70D mm -10°C to +50°C (no icing) 0 to 95% (non condensing) 151 grams Xpander Manual Call Point XPA-MC-14006-AMP Approvals: EN54-11/LPCB SEA/PAGE 60 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT WIRELESS TECHNOLOGY APOLLO XPANDER NEW Xpander Sounder and Sounder Base The XPander Sounder and Sounder Base is wireless and designed to be used with XPander detectors and manual call points only. • • • • Wall mounted Wireless – eliminates cable problems Self test feature Output is between 92 and 106dB(A) at 1m dependent on tone setting Voltage3VDC Alarm tones (selectable) 32 IP rating IP21C Sound output 100dB(A) Xpander Sounder and Sounder Base (Red) Xpander Sounder and Sounder Base (White) XPA-CB-14001-AMP XPA-CB-14002-AMP NEW Xpander Sounder Beacon and Sounder Base The XPander Sounder Beacon and Sounder Base is wireless and designed to be used with XPander detectors and manual call points only. • • • • SEA/PAGE 61 Wall mounted Eliminates cable problems Enables DDA compliance Self test feature CONTACT AMPAC Voltage3VDC Alarm tones (selectable) 32 IP rating IP21C Sound output 100dB(A) Xpander Sounder Beacon (Red) and Base (Red) Xpander Sounder Beacon (Amber) and Base (White) Xpander Sounder Beacon (Clear) and Base (White) HOME CONTENTS SEARCH ZOOM PRINT XPA-CB-14003-AMP XPA-CB-14004-AMP XPA-CB-14005-AMP EXIT WIRELESS TECHNOLOGY APOLLO XPANDER ANCILLARIES NEW Xpander Loop Interface Unit The XPander Loop Interface Unit communicates between the intelligent control panel and the XPander detectors as the detectors alone can’t communicate directly with the panel. • • • • • Connect up to 15 Xpander devices to a XP95 loop Translates radio signals from Xpander detectors to the control panel Incorporates an integral loop isolator and is polarity sensitive Loop powered Integral LCD display provides status of wireless devices Voltage24VDC Alarm current 15mA at 24 VDC Size inc back box 185H x 130W x 45D mm Operating temperature -10°C to +55°C (no icing) Relative humidity 0 to 95% (non condensing) Weight 1100 grams Xpander Interface Unit XPA-IN-14007-AMP NEW Xpander Survey Tool The XPander Survey Tool is used at the site survey stage to ascertain if a site is suitable for an XPander installation. A site survey must be carried out before XPander can be installed. • Tests for radio signal strength Xpander Survey Tool XPA-MC-14010-AMP Xpander External Aerial Xpander External Directional Aerial XPA-MC-14008-AMP XPA-MC-14009-AMP NEW Xpander Aerials There are two aerials to complement the Xpander range • Xpander External Aerial is used to strengthen the radio signals sent between the Xpander Interface Unit and Xpander devices • Xpander External Directional Aerial is used to pick up radio signals from outbuildings and annexes SEA/PAGE 62 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT AUDIO VISUAL SIGNALLING XP95/DISCOVERY INTELLIGENT Audio Visual Signalling Ampac offers a wide range of Intelligent Audio Visual (AV) signalling devices for use in conjunction with its range of intelligent and conventional detectors and control panels. A versatile and functional range offering a huge choice for any application. • Sounder Bases combine an alarm sounder and detector base • Beacon Bases combine an alarm beacon and detector base •Sounder Beacon Bases combine an alarm sounder, beacon and detector base • Sounders are used to provide an audible indication of an alarm • Beacons are used to provide an visual flashing indication of an alarm • Sounder/Beacons are used to provide an audible and flashing indication of an alarm SEA/PAGE 63 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT AUDIO VISUAL SIGNALLING XP95/DISCOVERY INTELLIGENT SOUNDER BASES Integrated Sounder Base The Integrated Sounder Base comprises a base sounder with integral mounting base and is for use with Discovery or XP95 ranges. It is designed for indoor use. • • • • • • Two volume ranges – 55-75dB and 75-91dB Synchronisation of ‘alert’ and ‘evacuate’ tones Individual and group addressing Unique acoustic self-test Integrated base Isolator option Voltage (polarity sensitive) Quiescent current Max current (sounder operated) Max sounder output Operating temperature Relative humidity IP rating Size Weight 17-28 VDC 1.2mA 5mA 83dB(A) -20°C to +60°C (no icing) 0 to 95% (non condensing) IP21D 115Dia x 38H mm 140 grams Integrated Base Sounder Integrated Base Sounder with Isolator Red Cap White Cap Approvals: LPCB EN54-3/LPCB 45681-278-AMP 45681-277-AMP 45681-293-AMP 45681-292-AMP Ancillary Sounder Base The Ancillary Sounder Base is a local-area sounder designed for indoor use. It can be connected only to detection systems using Discovery or XP95 detectors and control panels with appropriate software. • • • • • Guaranteed sound output of 85dB(A) at 1 metre Current consumption of only 3mA Loop-powered Responds to signals from the associated detector – does not have an address of its own Adjustable volume control Voltage (polarity sensitive) Quiescent current Max current (sounder operated) Max sounder output Operating temperature Relative humidity IP rating Size Weight 17-28 VDC 100µA 3mA 85dB(A) -20°C to +60°C (no icing) 0 to 95% (non condensing) IP23D 115Dia x 38H mm 140 grams Ancillary Base Sounder 45681-276-AMP Approvals: LPCB EN54-3/LPCB SEA/PAGE 64 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT AUDIO VISUAL SIGNALLING XP95/DISCOVERY INTELLIGENT BEACON BASES Loop-Powered Beacon Base The Beacon Base is a loop-powered beacon combined with a standard XP95/Discovery mounting base. It is used to signal a fire alarm in enclosed areas. The Beacon Base can be used either with a detector fitted or with a cap for operation as a stand-alone alarm device. • • • • • Beacon flash rate of once per second Synchronisation of beacon flash Individual and group addressing Unique beacon self-test Isolator option CONTACT AMPAC HOME 17-28 VDC 300µA 3.1mA -20°C to +60°C (no icing) 0 to 95% (non condensing) IP21D 115Dia x 31H mm 109 grams Beacon Base with Isolator Beacon Base Red Cap White Cap Approvals: LPCB EN54-3/LPCB SEA/PAGE 65 Voltage (polarity sensitive) Quiescent current Max current Operating temperature Relative humidity IP rating Size Weight CONTENTS SEARCH ZOOM 45681-333-AMP 45681-335-AMP 45681-293-AMP 45681-292-AMP PRINT EXIT AUDIO VISUAL SIGNALLING XP95/DISCOVERY INTELLIGENT SOUNDER BEACON BASES Sounder Beacon Base The Sounder Beacon Base is a loop-powered sounder and beacon combined with a standard Intelligent Mounting Base. It is used to signal a fire alarm in enclosed areas. The Sounder Beacon Base can be used either with a detector fitted or with a cap for operation as a stand-alone alarm device. • • • • • • • Two volume ranges 55-75dB(A) and 75-91dB(A) Beacon flash rate of once per second Synchronisation of ‘alert’ and ‘evacuate’ tones Synchronisation of beacon flash Individual and group addressing Unique acoustic and beacon self test Enables DDA compliance Voltage (polarity sensitive) Quiescent current Max current (sounder operated) Max sounder output Operating temperature Relative humidity IP rating Size Weight 17-28 VDC 300µA 8mA 91dB(A) -20°C to +60°C (no icing) 0 to 95% (non condensing) IP21D 115Dia x 38H mm 160 grams Sounder Beacon Base Sounder Beacon Base with Isolater 45681-331-AMP 45681-330-AMP Approvals: LPCB EN54-3/LPCB Discovery Sounder Beacon Base The Discovery Sounder Beacon Base is a multi-functional device comprising a mounting base for Discovery fire detectors, a sounder, a beacon and a short circuit isolator. It makes full use of the Discovery protocol and for ease of commissioning a ‘magnetic wand’ can be used to test and adjust each sounder locally. • Set individual control of the sounder and beacon • Select volume and tone settings from the control panel • Tones can be used for purposes in addition to fire – ideal for schools • Soft start option – ideal for hospitals and nursing homes • Electronic bell tone Voltage (polarity sensitive) Quiescent current Max current (sounder operated) Max sounder output Operating temperature Relative humidity IP rating Size Weight 17-28 VDC 350µA 8mA 90dB(A) -20°C to +60°C (no icing) 0 to 95% (non condensing) IP21D 115Dia x 31H mm 160 grams Discovery Sounder Beacon Base 45681-393-AMP Approvals: LPCB EN54-3/LPCB SEA/PAGE 66 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT AUDIO VISUAL SIGNALLING XP95/DISCOVERY INTELLIGENT SOUNDERS Intelligent 100dB(A) Open Area Sounder The Intelligent 100dB(A) Open Area Sounder is designed for use in open areas and can be connected to any Discovery or XP95 system. • • • • • • Output is 100dB (A) at 90° Current consumption of 5.0mA Can be synchronised Group address facility Loop powered Wall mounted Voltage (polarity sensitive) Quiescent current Max current (sounder operated) Max sounder output Operating temperature Relative humidity IP rating Size Weight 17-28 VDC 1.2mA 5mA 100dB(A) -20°C to +60°C (no icing) 0 to 95% (non condensing) IP21C 105L x 105W x 95H mm 215 grams Loop Powered Sounder (Red) Loop Powered Sounder (White) Approvals: LPCB EN54-3/LPCB 45681-278-AMP 45681-279-AMP Intelligent Weatherproof 100dB(A) Open Area Sounder The Intelligent Weatherproof 100dB(A) Open Area Sounder is designed for use in open areas and can be connected to any Discovery or XP95 system. The sounder comprises a backbox and sounder unit supplied together. • • • • • • • IP 66 (immune to the affects of wind and precipitation) Output is 100dB (A) at 90° Current consumption of 5.0mA Can be synchronised Group address facility Loop powered Wall mounted Voltage (polarity sensitive) Quiescent current Max current (sounder operated) Max sounder output Operating temperature Relative humidity IP rating Size Weight 17-28 VDC 1.2mA 5mA 100dB(A) -20°C to +60°C (no icing) 0 to 95% (non condensing) IP66 110L x 110W x 113H mm 340 grams Weatherproof Loop-Powered Sounder (Red) Weatherproof Loop-Powered Sounder (White) 45681-274-AMP 45681-275-AMP Approvals: LPCB EN54-3/LPCB SEA/PAGE 67 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT AUDIO VISUAL SIGNALLING XP95/DISCOVERY INTELLIGENT SOUNDERS NEW Intelligent Open-Area Sounder (Sonos) The Intelligent Open-Area Sounder has been designed for use in open areas and can be connected to any Discovery or XP95 system. • • • • • • Self-test fault monitoring Choice of tones Group addressing and synchronisation of alarm Weatherproof IP65 Comes with Isolating Base as standard Loop powered CONTACT AMPAC 17-28 VDC 333µA 5mA 100dB(A) -10°C to +55°C (no icing) 0 to 95% (non condensing) IP65 104Dia x 95.5H mm 225 grams Intelligent Open Area Sounder (Red) Sonos Intelligent Open Area Sounder (White) Sonos Approvals: LPCB EN54-3/LPCB SEA/PAGE 68 Voltage (polarity sensitive) Quiescent current Max current (sounder operated) Max sounder output Operating temperature Relative humidity IP rating Size Weight HOME CONTENTS SEARCH ZOOM PRINT 55000-001-AMP 55000-002-AMP EXIT AUDIO VISUAL SIGNALLING XP95/DISCOVERY INTELLIGENT BEACONS Loop-Powered Beacon The Loop-Powered Beacon is a local-area beacon designed for indoor use. The beacon has been developed as a supplement to sounders for use in situations where there is a risk that sounders will not be heard. • • • • • • • High intensity LED – more reliable than xenon beacons Automatic LED check Lockable Wide angle of visibility Enables DDA compliance Synchronised flash Can be used with Discovery or XP95 Voltage (polarity sensitive) Quiescent current Max current (beacon operated) Flash rate Operating temperature Relative humidity IP rating Size Weight 17-28 VDC 150µA 3mA 1Hz -20°C to +60°C (no icing) 0 to 95% (non condensing) IP23D 115Dia x 38H mm 140 grams Loop-Powered Beacon (Red) Loop-Powered Beacon (Clear Lens/Red Flash) Loop-Powered Beacon (Amber) 55000-877-AMP 55000-878-AMP 55000-879-AMP NEW Intelligent Open-Area Beacon (Sonos) The Intelligent Open-Area Beacon has been developed for use in situations where there is a risk that sounders will not be heard. It is weatherproof and can be used outside. • • • • • • SEA/PAGE 69 Self-test fault monitoring Weatherproof IP65 Group addressing Synchronisation of alarm Comes with Isolating Base as standard Loop powered CONTACT AMPAC HOME Voltage (polarity sensitive) Quiescent current Max current (beacon operated) Flash rate Operating temperature Relative humidity IP rating Size Weight 17-28 VDC 333µA 3.1mA 1Hz -10°C to +55°C (no icing) 0 to 95% (non condensing) IP65 104Dia x 97.5H mm 205 grams Intelligent Open Area Beacon (Red) Sonos Intelligent Open Area Beacon (Clear) Sonos CONTENTS SEARCH ZOOM PRINT 55000-009-AMP 55000-010-AMP EXIT AUDIO VISUAL SIGNALLING XP95/DISCOVERY INTELLIGENT SOUNDER/BEACONS Multi-Tone Open-Area Sounder Beacon The Multi-Tone Open-Area Sounder Beacon is designed for use in indoor open areas and can be connected to any Discovery or XP95 system. The sounder beacon complements Apollo’s open area integrated base sounders as well as the intelligent 100dB(A) open area sounder. • • • • • • Powerful LED combined with 100dB sound output Two volume settings Synchronisation of ‘alert’ and ‘evacuate’ tones Individual and group addressing Three tone choices Enables DDA compliance Voltage (polarity sensitive) Quiescent current Max current (sounder/beacon operated) Max sounder output Flash rate Operating temperature Relative humidity IP rating Size Weight 17-28 VDC 333µA 9mA 100dB(A) 1Hz -10°C to +55°C (no icing) 0 to 95% (non condensing) IP21C 105L x 105W x 50H mm 209 grams Multi-Tone Open-Area Sounder Beacon (Red) with Isolator Multi-Tone Open-Area Sounder Beacon (White) with Isolator Approvals: LPCB EN54-3/LPCB 55000-293-AMP 55000-294-AMP Weatherproof Multi-Tone Open-Area Sounder Beacon The Weatherproof Multi-Tone Open-Area Sounder Beacon is designed for use in outdoor open areas and can be connected to any Discovery or XP95 system. The sounder beacon complements Apollo’s intelligent and integrated base sounders as well as the loop powered 100dB sounder. • • • • • • • IP66 (immune to the affects of wind and precipitation) Powerful LED combined with 100dB sound output Two volume settings Synchronisation of ‘alert’ and ‘evacuate’ tones Individual and group addressing Three tone choices Enables DDA compliance Approvals: LPCB EN54-3/LPCB SEA/PAGE 70 CONTACT AMPAC HOME CONTENTS Voltage (polarity sensitive) Quiescent current Max current (sounder/beacon operated) Max sounder output Flash rate Operating temperature Relative humidity IP rating Size Weight 17-28 VDC 333µA 9mA 100dB(A) 1Hz -20°C to +70°C (no icing) 0 to 95% (non condensing) IP66 110L x 110W x 113H mm 294 grams Weatherproof Multi-Tone Open-Area Sounder Beacon (Red) with Isolator Weatherproof Multi-Tone Open-Area Sounder Beacon (White) with Isolator SEARCH ZOOM PRINT EXIT 55000-298-AMP 55000-299-AMP AUDIO VISUAL SIGNALLING XP95/DISCOVERY INTELLIGENT SOUNDER/BEACONS NEW Intelligent Open-Area Sounder Beacon The Intelligent Open-Area Sounder Beacon has been designed for use in open areas and can be connected to any Discovery or XP95 system. • • • • • • Gives two functions at one point Self-test fault monitoring Choice of tones Group addressing and synchronisation of alarm Comes with Isolating Base as standard Loop powered Approvals: LPCB EN54-3/LPCB SEA/PAGE 71 CONTACT AMPAC Voltage (polarity sensitive) Quiescent current Max current (sounder/beacon operated) Max sounder output Flash rate Operating temperature Relative humidity IP rating Size Weight 17-28 VDC 333µA 8mA 100dB(A) 1Hz -10°C to +55°C (no icing) 0 to 95% (non condensing) IP65 104Dia x 97.5H mm 260 grams Intelligent Open Area Sounder Beacon (Red) Sonos Intelligent Open Area Sounder Beacon (Clear) Sonos HOME CONTENTS SEARCH ZOOM PRINT EXIT 55000-005-AMP 55000-006-AMP AUDIO VISUAL SIGNALLING AMPAC BELLS Fire Alarm Bell 150mm •Motorised mechanism •Low current consumption •Red finish with FIRE lettering • Suitable for indoor use •Back box available – 206-0006 Voltage Operating current Size (without back box) Sound Level Operating temperature Weight 24 VDC 25mA 150Dia x 56D mm 92 dB @ 3m -10°C to +55°C (no icing) 764 grams Bell 150mm 206-0012 Fire Alarm Bell 200mm • • • • Red finish with FIRE lettering Solenoid actuating mechanism Suitable for indoor use Back box available – 206-0006 Voltage 19-27 VDC Operating current 100mA Size (without back box) 200Dia x 70D mm 85 dB @ 3m Sound Level -20°C to +70°C (no icing) Operating temperature Weight1.25kg Bell 200mm 24Vdc 206-0001 Bell Back Box • • • • Allows surface mounting of bell Screw thread conduit entry and protection for wiring terminals Red finish Weather seal Material Aluminium cast FinishRed Depth 40 mm Weight 270 grams Bell Back Box for 206-0012 and 206-0001 SEA/PAGE 72 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 206-0006 EXIT AUDIO VISUAL SIGNALLING AMPAC STROBES ASL-30 Xenon Beacon/Strobe •Red, amber, or blue lens options • Compact size • ABS/polycarbonate/acrylic construction • Easy-fit BESA, junction box adaptor/mounting base Voltage Current (at 24 VDC ) Size inc base Flash rate Operating temperature IP rating Weight inc base 20 to 28 VDC 1W 42mA 3W 135mA, 5W 155mA 77Dia x 65H mm 60 per minute -30°C to + 70°C IP65 106 grams ASL-30 Strobe 24Vdc Red 1 Watt ASL-30 Strobe 24Vdc Red 3 Watt ASL-30 Strobe 24Vdc Red 5 Watt ASL-30 Strobe 24Vdc Amber 1 Watt ASL-30 Strobe 24Vdc Amber 3 Watt ASL-30 Strobe 24Vdc Amber 5 Watt ASL-30 Strobe 24Vdc Blue 1 Watt ASL-30 Strobe 24Vdc Blue 3 Watt ASL-30 Strobe 24Vdc Blue 5 Watt ASL-30 Strobe Adapter Plate SEA/PAGE 73 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM 208-0030 208-0032 208-0033 208-0034 208-0036 208-0037 208-0038 208-0040 208-0041 208-0024 PRINT EXIT AUDIO VISUAL SIGNALLING AMPAC REMOTE INDICATORS Fire Alarm Remote Indicator – Round •Detector activation indicator • 5mm Red LED • Compact size • Modern styling • For conventional or analogue detectors • Choice of legend Voltage Current at 24v Size Weight 24 VDC 1.5mA 74Dia x 16H mm 26 grams Remote Indicator – Blank Remote Indicator – Fire Alarm in Concealed Space Remote Indicator – Fire Alarm in Roof Space Remote Indicator – Fire Alarm in Room Remote Indicator – Fire Alarm in Duct Remote Indicator – Fire Alarm in Cupboard Remote Indicator – Fire Alarm Remote Indicator – Detector Activated 209-0001 209-0004 209-0005 209-0006 209-0007 209-0008 209-0020 209-0023 Fire Alarm Flashing Indicator/Buzzer with Mute • Alarm activation indicator and buzzer •10mm red flashing LED •Buzzer with mute facility • M odern styling Voltage Current at 24v LED flash rate Buzzer Size (UK single gang plate) Weight 24 VDC 43mA 45 per minute 3.8kHz @ 114dBA 86H x 86W x 5D mm 89 grams Flashing Indicator/Buzzer with Mute Switch SEA/PAGE 74 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT 209-0022 EXIT AUDIO VISUAL SIGNALLING FULLEON SOUNDERS Roshni Sounder The Roshni Low Profile (RoLP) is the fire alarm markets leading conventional alarm sounder. The wide operating voltage and range of tones available to the user make this flexible sounder supremely adaptable in even its most basic forms. • • • • • • • • High sound output Low current consumption 32 tones (user selectable) Automatic synchronisation Volume control Second tone for two stage alarms Lockable base Suitable for outdoor use (deep and ‘U’ base only) Voltage 9 - 28Vdc 16mA (Typical Tone 3) Current Sound Output 102dB(A) (Typical Tone 3) Tones32 Volume Control 20dB Monitoring Reverse polarity -25°C to +70°C Temperature Protection IP54 (shallow base) IP65 (deep/’U’ base) ConstructionABS Size 93mm Dia x 63mm H (shallow base) 93mm Dia x 93mm H (deep base) Weight0.25Kg Roshni Sounder, red, shallow base Roshni Sounder, red, deep base Roshni Sounder, red, deep ‘U’ base Approvals: EN54-3/LPCB ROLP/R/S ROLP/R/DB ROLP/R/U 110/230 VAC versions available on request SEA/PAGE 75 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT AUDIO VISUAL SIGNALLING FULLEON SOUNDERS Squashni G3 The third generation Squashni G3 amalgamates the best features of the Squashni and Squashni Micro into a single sounder. The large flat surface allows the mounting of most popular European detectors, while the high efficiency and low operating current permit compatibility with many systems. A combined audible and visual version is also available. • • • • • • SEA/PAGE 76 Fixing platform for most popular detectors Low current consumption Tamper proof cap for standalone use (supplied separately) First fix base for easier installation Combined sounder & beacon version available Led triggered option available CONTACT AMPAC HOME CONTENTS Voltage 18 - 28Vdc Current4/5mA Sound Output 90dB(A) Tones8 Volume Control 10dB Monitoring Reverse polarity -10°C to +55°C Temperature ProtectionIP21C ConstructionABS Size 114mm Dia x 35mm H Weight0.16Kg ColoursWhite Squashni Ceiling Base Sounder Blanking Cover/Cap (Pack of 5) SEARCH ZOOM SQ/G3/W SQ/G3/CAP PRINT EXIT AUDIO VISUAL SIGNALLING FULLEON BEACONS Solista LED Beacon LED beacons are available to complement audible alarms for use in areas where people may be present who have impaired hearing or areas with high ambient noise levels. LED technology offers a greatly reduced current consumption compared to Xenon types making them ideal for use with fire panels with restricted sounder circuit current capacity. • • • • • Ultra low current – LED technology High reliability Long service life Locking base Compact size Voltage 10 - 30Vdc 3m - 5mA (user selectable) Current Light Output >0.5Cd or 1Cd (user selectable) Flash Rate 0.5Hz / 1Hz (user selectable) Monitoring Reverse polarity Temperature -10°C to +55°C IP21C (shallow base) Protection IP33C (deep base) Construction ABS, PC lens Size 93mm Dia x 53mm H (shallow base) 93mm Dia x 83mm H (deep/U base) Weight0.1Kg Solista LED Beacon, shallow base Solista LED Beacon, deep base Solista LED Beacon, ‘U’ base SOL/RL/R/S SOL/RL/RD SOL/RL/RU 110/230 VAC versions available on request SEA/PAGE 77 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT AUDIO VISUAL SIGNALLING FULLEON SOUNDER / BEACONS RoLP Solista Sounder/LED Beacon The use of beacons to supplement audible alarms is becoming increasingly common. A combined sounder beacon allows both an audible and visual alarm to be provided but requires only a single installation point. LED beacons have a dramatically lower current consumption than that of traditional xenon beacons making them ideal for applications where sounder circuit capacity is limited. • • • • • Ultra low current – LED technology Sounder & beacon with a single installation point Unobtrusive low profile design Standard Fulleon base simplifies system upgrades Lockable base Voltage 9 - 28Vdc 19mA (Typical Tone 3) Current Sound Output 101dB(A) (Typical Tone 3) Tones32 Light Output > 0.5Cd Flash Rate 1Hz 20dB Volume Control Monitoring Reverse polarity Temperature -10°C to +54°C Protection IP54 (shallow base) IP65 (deep base) ABS, PC lens Construction Size 93mm Dia x 78mm H (shallow base) 93mm Dia x 110mm H (deep/U base) Weight0.3Kg RoLP Solista Sounder/LED Beacon, shallow base RoLP Solista Sounder/LED Beacon, deep base ROLPSB/RL/R/S ROLPSB/RL/RD 110/230 VAC versions available on request SEA/PAGE 78 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT AUDIO VISUAL SIGNALLING KAC MANUAL CALL POINTS KAC Indoor Manual Call Point The KAC Indoor Manual Call Point can be configured as either a break glass or resettable unit by simply changing from one element to another. No other additional parts or alternative products need to be ordered. All MCP indoor call point products also help preserve the integrity of the overall system as illegal removal of the product lid will result in the call point operating and the system going into alarm. Full compliance with the latest standards is essential and the new MCP indoor call point range is fully approved to the latest EN54-11 standard. The MCP1B product version allows for connection to ‘Savwire’ systems. • • • • • • Unique ‘Plug & Play’ installation concept Total ‘Flex-Ability’ in the choice of operating element Anti-Tamper facility Enhanced aesthetics Fully approved to the latest standards Backward compatibility CONTACT AMPAC HOME Indoor MCP, red, surface, glass element Indoor MCP, red, surface, resettable flexible element Indoor MCP, red, flush, glass element Indoor MCP, red, flush, resettable flexible element Indoor MCP, yellow, surface, glass element MCP1A-R470SG-01 MCP1A-R470SF-01 MCP1A-R470FG-01 MCP1A-R470FF-01 MCP1A-Y470SG-11 MCP1B-R470SG-01 Indoor MCP, Savwire, red, surface, glass element Indoor MCP, Savwire, red, surface, resettable flexible element MCP1B-R470SF-01 Indoor MCP, Savwire, red, flush, glass element MCP1B-R470FG-01 Indoor MCP, Savwire, red, flush, resettable flexible element MCP1B-R470FF-01 Approvals: EN54-11/LPCB SEA/PAGE 79 Voltage 30 VDC 2 Amps – 30 VDC Contact rating (switch only) Resistor470Ω Operating temperature -10°C to +55°C Humidity 0-95% (no condensation) IP rating IP24D 93H x 89W x 27.5D mm Size (flush mount) Size (surface mount) 93H x 89W x 59.5D mm Weight (flush mount) 110 grams Weight (surface mount) 160 grams CONTENTS SEARCH ZOOM PRINT EXIT AUDIO VISUAL SIGNALLING KAC MANUAL CALL POINTS KAC Outdoor Manual Call Point The outdoor WCP is an IP67 sealed manual call point product. The enhanced environmental protection allows the unit to be installed in many external environments where water and dirt are likely to be present, making it a true waterproof and outdoor product. • • • • • • Sealed to IP67 Unique ‘Plug & Play’ installation concept Total ‘Flex-Ability’ in the choice of operating element Anti-Tamper facility Enhanced aesthetics and compact design Fully approved to the latest standards Voltage 30 VDC 2 Amps – 30 VDC Contact rating (switch only) Resistor470Ω Operating temperature -30°C to +70°C Humidity 0-95% (no condensation) IP rating IP67 93H x 97.5W x 71D mm Size Weight 240 grams Outdoor MCP, red, surface, glass element Outdoor MCP, red, surface, resettable flexible element Outdoor MCP, yellow, surface, glass element Outdoor MCP, Savwire, red, surface, break glass element Approvals: EN54-11/LPCB WCP1A-R470SG-K13-01 WCP1A-R470SF-K13-01 WCP1A-Y470SG-K13-11 WCP1B-R470SG-K13-01 KAC Outdoor Manual Call Point Accessories • Spare or replacement call point test key • Transparent protective cover • Replaceable flexible or glass elements SEA/PAGE 80 CONTACT AMPAC HOME Flexible Element for Resettable Call Points Universal Transparent Hinged Cover Universal Test Key for KAC Call Points – Pack of 10 Glass Elements – Pack of 10 CONTENTS SEARCH ZOOM PRINT PS210 PS200 SC070 KG1 x10 EXIT AUDIO VISUAL SIGNALLING KLAXON SONOS SOUNDERS / LED BEACONS Sonos Sounder A general purpose electronic sounder for fire, security and industrial applications.. Deep base units have weatherproof protection to IP65 and can be used in all locations both indoors and outdoors. • • • • • • Simple `First Fix` installation – TimeSaver base Smooth flow cabling for faster installation Quick connect/disconnect Tone and volume can be preset or adjusted off-base Weatherproof to IP65 (deep base units) Synchronised alarm tones Audibility at 1m (tone dependent) Up to 106dB (A) Tones32 Voltage 9-60V DC Current (tone dependent) 4-41mA IP Rating IP65 (deep base) Operating temperature -25°C to +70°C 215 grams (shallow base) Weight 250 grams (deep base) Red Sonos Sounder, shallow base Red Sonos Sounder, deep base White Sonos Sounder, shallow base White Sonos Sounder, deep base Approvals: EN54-3/LPCB 18-980450-AMP 18-980451-AMP 18-980475-AMP 18-980476-AMP Sonos LED Beacon A general purpose beacon for fire, security and industrial applications. Deep base units have weatherproof protection to IP65 and can be used in all locations both indoors and outdoors. The Sonos Beacon utilises a full faced, translucent case which provides a much larger lens area and a greater spread of light. • Simple `First Fix` installation – TimeSaver base • Weatherproof to IP65 (deep base units) • High efficiency LED beacon consumes less than 5mA • Low current LED beacon as standard SEA/PAGE 81 CONTACT AMPAC HOME Voltage 17-60V DC Current5mA IP65 (deep base) IP Rating Operating temperature -25°C to +70°C Weight 215 grams (shallow base) 250 grams (deep base) Red Lens Sonos LED Beacon, red shallow base Red Lens Sonos LED Beacon, red deep base Clear Lens Sonos Red LED Beacon, white shallow base Clear Lens Sonos Red LED Beacon, white deep base CONTENTS SEARCH ZOOM PRINT EXIT 18-980507-AMP 18-980508-AMP 18-980609-AMP 18-980610-AMP AUDIO VISUAL SIGNALLING KLAXON SONOS SOUNDER BEACONS & BASES Sonos Sounder Beacon A general purpose electronic sounder beacon for fire, security and industrial applications. Deep base units have weatherproof protection to IP65 and can be used in all locations both indoors and outdoors. A full faced, translucent sounder case rather than a separate add-on beacon gives a much larger lens area and a greater spread of light. • • • • • • Simple `First Fix` installation – TimeSaver base Quick connect/disconnect Tone and volume can be preset or adjusted off-base Weatherproof to IP65 (deep base units) Low current LED beacon Sounder and beacon can be controlled separately Audibility at 1m (tone dependent) Up to 106dB (A) Tones32 Voltage 17-60V DC Current 4-45mA (sounder) 5mA (beacon) IP Rating IP65 (deep base) -25°C to +70°C Operating temperature Weight 215 grams (shallow base) 250 grams (deep base) Red Lens Sonos LED Beacon, shallow base Red Lens Sonos LED Beacon, deep base Clear Lens Sonos LED Beacon, shallow base, red LEDs Clear Lens Sonos LED Beacon, deep base, red LEDs Approvals: EN54-3/LPCB 18-980500-AMP 18-980501-AMP 18-980607-AMP 18-980608-AMP Sonos Universal Sounder Base / Sounder Beacon Base The Sonos Universal Base Sounder Base and Sounder Beacon Base are low profile units. Their prime application is to be installed under proprietary smoke and heat detectors to provide both detection and alarm at the same point, reducing wiring and installation costs. • • • • • • Two large cable entries for quick and simple installation Keyhole fixing points for ease of installation Designed to complement a variety of detectors Volume control for maximum flexibility Cover plate available for use as a sounder or sounder beacon only Unique beacon design for optimised light coverage Approvals: EN54-3/LPCB SEA/PAGE 82 CONTACT AMPAC HOME CONTENTS Audibility at 1m (tone dependent) Up to 95dB (A) Voltage 17-60V DC Tones32 Current2-8mA Operating temperature -10°C to +55°C 100 grams Weight Universal Base Sounder – white Universal Base Sounder – cream Universal Base Sounder LED Beacon – white Universal Base Sounder LED Beacon – cream Base Sounder Cover – white Base Sounder Cover – cream SEARCH ZOOM PRINT 18-980532-AMP 18-980533-AMP 18-980682-AMP 18-980685-AMP 18-980560-AMP 18-980564-AMP EXIT CONTACT SINGAPORE MALAYSIA Twilight Vision Pte Ltd 1 Yishun Street 23 #04-50 YS-ONE Singapore 768441 Demiplex Sdn Bhd No 56 Jalan BP 5/11 Bandar Bukit Puchong Malaysia 47100 Telephone: +65 6752 7335 Fax: +65 6481 0046 Email: [email protected] Web: www.twilightvision.com.sg Telephone: +603 8060 2121 Fax: +603 8068 2525 Web: www.demiplex.com Contact: Vincent Chan Contact: Timothy Kang HEAD OFFICE – PERTH Ampac Technologies Pty Ltd 7 Ledgar Road, Balcatta, Western Australia, 6021 Telephone: +618 9201 6100 Fax: +618 9201 6101 Email: [email protected] Web: www.ampac.net As part of Ampac’s commitment to continuous improvement, specifications may change without notice. Version SEA 17/5/2012 Planned, written, designed and produced by Right Angle • www.rightangle.co.uk SEA/PAGE 83 CONTACT AMPAC HOME CONTENTS SEARCH ZOOM PRINT EXIT
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement