Quick Start Guide
Refer to the Owner’s Manual for more details
Model No: 47001 - 47009
OXYPURE® SMART AIR PURIFIER
Air/Odor Quality - Detects particles as small as 2.5/1000mm
RESET FILTER 2
HOLD FOR 2 SECONDS
POWER
AUTO
ULTIMATE
CLEAN
FAN
SPEED
LOW
ECO-FRIENDLY MODE
HIGH
RESET FILTER 4
Low PM Level
HOLD FOR 2 SECONDS
High PM Level
Particulate Matter (PM) with a diameter of 2.5 microns or less
TIMER
TURBO
HR
HR
SLEEP MODE
AIR
CLEAN
WIFI
ODOR
DIRTY
CLEAN
FILTER 2
NO
ODOR
STRONG
ODOR
REPLACE
FILTER 4
0~5
5~10
10~20
20~30
30~50
Over 50
5
6
Fan Speeds
1
2
3
4
See the Owner’s Manual for details.
Name
Function
Use
POWER
Turns the OxyPure® on and off.
Press POWER to turn the OxyPure® on and off.
Wi-Fi
MODE
Allows you to connect the OxyPure to your Wi-Fi
network
Press and hold POWER to initiate Wi-Fi pairing.
AUTO
AUTO
Allows you to run the OxyPure at the lowest fan
speed, raising it based on PM level.
Press AUTO and the Auto back light will turn on. There is no time limit on the Auto Mode. Press
AUTO again to deactivate Auto Mode.
+
ECO
MODE
Allows you to save energy by keeping the OxyPure
fan off until it’s needed.
Press and hold POWER and ULTIMATE CLEAN to activate Eco Mode. The Power icon backlight
will be yellow while in Eco Mode.
Automatically switches to the highest fan speed
when the PM level rises.
Press ULTIMATE CLEAN to activate the Ultimate Clean Mode.
Button
ULTIMATE
CLEAN
ULTIMATE
CLEAN
ULTIMATE
CLEAN
FAN
SPEED
FAN
SPEED
Adjusts the OxyPure’s fan speed.
There are 6 fan speed levels. Press FAN SPEED to adjust from Speed 1 (lowest) to Speed 6
(highest).
SLEEP MODE
SLEEP
MODE
Turns off the control panel LED lights but keeps the
fan active.
Adjust the Fan Speed prior to activating Sleep Mode. Press and hold FAN SPEED for 2 seconds to
activate Sleep Mode.
TIMER
TIMER
Sets a countdown timer to shut off the OxyPure or
end the current function.
Press TIMER to select from the 6 timer settings of 1/2, 1, 2, 4, 8 or 12 hours.
TURBO
Operates at fan speed 6 for a set time.
Press TURBO to set the OxyPure to run at the highest speed for 1/2, 1 or 2 hours.
AIR
Air Quality Indicator
The color coded display shows the current particulate matter level in the air.
ODOR
Odor Indicator
The color coded display shows the current odor level in the air.
LOW
HIGH
HR
TURBO
HR
AIR
CLEAN
DIRT
ODOR
NO
ODOR
STRONG
ODOR
Wi-Fi LED Status
Pairing Mode & AP Mode
Before Use
1.
Make sure the OxyPure® is unplugged. Open the panel on the back to
expose the filters.
2.
Pull the filters from their slots.
3.
Remove the plastic wrapping from the filters.
4.
Fully reinsert the filters into the Oxypure and close the panel.
5.
Remove the sticker from the control panel.
Wi-Fi Connection (Optional)
Connect the OxyPure to your home Wi-Fi network and pair it with
your smart device:
1.
2.
3.
4.
5.
Download the NuWave® Connect app via the Apple Store or
Google™ Play Store on your smartphone or device and open
the app.
Once you download the NuWave® Connect app, ensure your
phone is connected to your home Wi-Fi network on the 2.4GHz
frequency and that your phone’s Bluetooth is on.
Turn on the OxyPure and activate Wi-Fi Pairing Mode by
pressing and holding POWER until the light next to the Wi-Fi
symbol begins to blink rapidly.
In the NuWave® Connect app, tap the + symbol, then tap Auto
Scan and select your device.
Enter your Wi-Fi network’s password and tap Confirm. If
the connection is successful, the app will display “Added
Successfully” on the screen.
Solid Light
The OxyPure® is paired with the Wi-Fi and
ready to be used.
Rapid Blinking Light
The OxyPure is in Pairing Mode. The OxyPure
will remain in Pairing Mode for up to 3 minutes,
or until your device is paired.
Slow Blinking Light
The OxyPure is in AP Mode.
No Light
The OxyPure’s Wi-Fi is off.
Filters
1
Stainless-Steel Prefilter (Lifespan up to 20 years)
•
Made from rust-free 18/8 stainless-steel.
•
The durable, washable and reusable Prefilter captures and collects large
particles
2
Bio-Guard® Filter (Lifespan up to 20 years)
•
The 8,000-volt electrostatic filter captures airborne particles as small as 0.1
microns..
3
Ozone (O3 ) Emission Removal Filter (Lifespan up to 20 years)
•
4
Eliminates harmful ozone gas from the home, reducing ozone levels to
less than 1 ppb – 70 times lower than the EPA’s household standard of
70 ppb.
2-in-1 HEPA/Carbon Filter (Lasts up to 1 year)
•
The double-sided filter traps airborne particles like pollen and pet dander
while also trapping smoke, unwanted odors and VOCs.
1
If you’re unable to pair your OxyPure using Auto Scan, follow
the instructions for AP Mode or EZ Mode on page 9 of the
owner’s manual.
Customer Service: [email protected]
2
3
4
Air Filter Assembly
Open
Access to Filters
When maintaining the filters, unplug the unit and open the Filter Access
Panel. You will see that the order of the filters, from the outside in, is as
follows:
1 Stainless-Steel Prefilter
Removing &
Inserting Filters
4
3
2
1
2 Bio-Guard Filter
®
3 Ozone Emission Removal Filter
4 HEPA/Carbon Filter
CAUTION
Unplug the OxyPure® from the power source before inserting or removing any parts or attachments and before cleaning.
The OxyPure® is easily movable with wheels on the bottom. Before moving your OxyPure, turn it off and unplug it from the outlet. Your settings will be saved
and will automatically activate next time the unit is turned on.
Cleaning & Maintenance
Filter Maintenance Indicator
•
The FILTER 2 light will turn green after about 3 months to alert you that the Bio-Guard filter SHOULD be cleaned to maintain optimal performance. The light
will turn red after about 6 months, indicating that the Bio-Guard filter MUST be cleaned. Once cleaned, press and hold TIMER to reset the indicator light.
•
The FILTER 4 light will turn green after about 6 months to alert you that the HEPA/Carbon filter SHOULD be replaced to maintain optimal performance. The
light will turn red after about 12 months, indicating that the HEPA/Carbon filter MUST be replaced. Once replaced, press and hold TURBO for 2 seconds to
reset the indicator light.
Cleaning the Filters
The filters need to be cleaned on schedule to help the unit maintain optimum performance.
1. Remove the Filter Access Panel in the r ear of the OxyPure® using its built-in handle.
2.
Slide out the filters that need cleaning and spray with a mild detergent, then wipe clean.
3.
Always allow the washable filters to dry completely, out of direct sunlight, before you reinstall them. Never place a wet filter into the OxyPure.
4.
Reattach and close the Filter Access Panel. If the panel is not properly closed, the POWER button will blink red and the unit will not power on.
NOTE: The HEPA/Carbon filter cannot be cleaned.
Customer Service: [email protected]
General Filter Cleaning Tips
1.
Always Wear a Mask and Use Rubber gloves.
Prevents accidental inhalation of any contaminants when cleaning
your filters.
Cleaning the Dust Sensor
The Dust Sensor is located on the side of
the unit.
1. Open the Dust Sensor Cover.
2.
Move the OxyPure, Not the Filters
Minimizes filter shaking.
2.
Using a dry cotton swab, gently remove
any dirt or dust from the Dust Sensor.
3.
Handle the Filters Carefully
Be careful not to agitate the filters to avoid releasing trapped
contaminants.
3.
For more buildup on the Dust Sensor,
wipe it with a slightly wet cotton swab.
4.
Dry the Filters Completely
Never install a wet or damp filter into your OxyPure.
4.
Remove any moisture with a dry cotton
swab.
HR
HR
TIMER
ECO-FRIENDLY MODE
ULTIMATE
CLEAN
HIGH
FAN
SPEED
REPLACE
FILTER 4
DIRTY
NO
ODOR
STRONG
ODOR
ODOR
AIR
HOLD FOR 2 SECONDS
RESET FILTER 4
WIFI
SLEEP MODE
LOW
AUTO
CLEAN
TURBO
HOLD FOR 2 SECONDS
RESET FILTER 2
POWER
CLEAN
FILTER 2
WIFI
HIGH
FAN
SPEED
HR
TIMER
HOLD FOR 2 SECONDS
RESET FILTER 2
HR
TURBO
CLEAN
FILTER 2
CLEAN
REPLACE
FILTER 4
DIRTY
AIR
NO
ODOR
Do not dry the filters in direct sunlight or
with a hot blow dryer.
SLEEP MODE
STRONG
ODOR
To Clean the Stainless-Steel Prefilter
The Prefilter needs to be cleaned at least once every two months,
depending on use.
1. Use a brush-tipped vacuum to remove any dust or lint.
LOW
Repeat the process on the other side. DO NOT GET WET.
ULTIMATE
CLEAN
3.
Do not immerse the OxyPure in water.
Clean the outside of the unit with a damp
sponge or cloth and wipe it dry. Make
sure all parts and covers are securely
attached.
AUTO
Gently, but thoroughly, clean the filter using a brush-tipped vacuum.
ECO-FRIENDLY MODE
2.
POWER
To Clean the Ozone Emission Removal Filter
1. Remove the filter. If possible, take them outside to clean.
NOTE: Consult the OxyPure Owner’s Manual
for more detailed cleaning instructions.
ODOR
HOLD FOR 2 SECONDS
RESET FILTER 4
Cleaning the Odor Sensor
1. The Odor Sensor is behind the three slots above the Dust Sensor
Cover and may ONLY be cleaned using a brush-tipped vacuum.
Note: If you are unable to close the Filter Access Panel for any
reason, the OxyPure will not operate and you will need to contact
NuWave Customer Service. Exercise caution to ensure the
tabs are not damaged when securing the Filter Access Panel.
Open
4
3
2
1
OXYPURE® SMART AIR PURIFIER
©2023 NuWave® LLC • All Rights Reserved. • Customer Service:[email protected]
Item: BQ47001- 47009 • Rev.1-V5-CB • 07-21-23
EPA Establishment Number: 101594-CHN-1
">