Rockit Complete is a rail-less PV racking system designed for composition shingle, tile, and metal pitched and flat rooftops. It is the industry's premier rail-less PV racking system. Rockit Complete quickly & easily installs with a single tool. It features an easy-to-position mount alignment and a top-down leveling system. Rockit Complete is logistically intelligent with no need to ship or transport long rails. Components are available in a black finish that compliments both commercial and residential applications.
PDF
Download
Document
Advertisement
Advertisement
COMPLETE RAIL-LESS RACKING SYSTEM INSTALLATION GUIDE REVISION DATE: 06/28/23 VERSION: v3.3 ECOFASTENSOLAR.COM REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE TABLE OF CONTENTS PAGE 01 FEATURES & BENEFITS PAGE 02 SYSTEM SPECIFICATIONS PAGE 03 COMPONENTS PAGE 04 RATINGS PAGE 05 PLACEMENT PAGE 06 INSTALLATION PAGE 08 SUPPLIMENTAL GUIDES PAGE 17 METAL ROOFS PAGE 18 GROUNDING PAGE 19 COMPATIBLE MODULES PAGE 21 TABLE OF CONTENTS Clicking the page name will take you to that page PAGE 01 REVISION DATE: 06/28/23 VERSION: v3.3 ROCKIT The RockIt system conforms to UL 2703 and is the industry’s premier rail-less PV racking system for composition shingle, tile, and metal pitched and flat rooftops. Designed in conjunction with installers, RockIt quickly & easily installs with a single tool. It features an easy-to-position mount alignment and a top-down leveling system. RockIt is logistically intelligent with no need to ship or transport long rails. Components are available in a black finish that compliments both commercial and residential applications. FEATURES • Patented Watertight Technology • Fully integrated bonding FEATURES+BENEFITS INSTALLATION GUIDE • Top-down leveling system • North-South adjustability • Single tool install PAGE 02 REVISION DATE: 06/28/23 VERSION: v3.3 ROCKIT SYSTEM SPECIFICATIONS Leveling Range 3.25"– 4.5" above the roof Materials 300 series stainless steel, 6000 series aluminum North-South Slide Range Slide dependent 3-7 inches Finish Black anodization/Mill finish Warranty 25 year material and workmanship TOOL LIST Comp Slide & Flashings • 7/32” Drill bit • ½" Deep-well socket (not thick wall impact) • Chalk line • String line (optional) Smart Slide • ½" Deep-well socket (not thick wall impact) • 5/16" Nutdriver for impact with 2" extension • Chalk line • String line (optional) SYSTEM SPECS INSTALLATION GUIDE PLEASE NOTE: Review module and any third-party manufacturer’s documentation for compatibility and compliance with warranty terms and conditions. WARNING: This product must be installed and used according to this written instruction. Any installation or use of this product not in accord with or not authorized by this written instruction shall void any and all warranties, expressed or implied, on the product or the use of the product and may cause failure, property damage and personal injury. EcoFasten is not liable for any unauthorized use. Install and use only with other EcoFasten products to ensure proper fit and function. PAGE 03 REVISION DATE: 06/28/23 VERSION: v3.3 SYSTEM COMPONENTS INSTALLATION GUIDE ROCKIT SYSTEM MOUNT SKIRT & END CAP COUPLING COMP SLIDE LAG SCREW GF-1 FLASHING SMART SLIDE SMART SLIDE SMART SCREW OTHER ROOF ATTACHMENTS FIND INSTALLATION GUIDES ON WEBSITE FLAT ROOFS SIMPLEGRIP COMP SLIDE STANDING SEAM ROOFS SIMPLEBLOCK-U COMP SLIDE CORRUGATED METAL ROOFS STEEL SLIDE SELF-PIERCING SCREW TILE ROOFS TILE BASE TILE SLIDE COMPONENTS COMP ROOF ATTACHMENTS COMP SLIDE & FLASHING TILE FLASHING (FLAT, S & W) SYSTEM ACCESSORIES FRAME MLPE MOUNT JUNCTION BOX CONDUIT BRACKET - COMP CONDUIT BRACKET - TILE PAGE 04 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE Fire Ratings Class A* and B** System Fire Rating Max System Voltage 1500V Max Fuse Rating 40A Certification Conforms to UL STD 2703 and UL SUBJECT 2703A Markings Product listing label is located on RockIt Mount Roof Pitch 0 to 21:12 (0 to 60 degrees) UL 2703 Allowable Design Load Rating 30 psf downward, 30 psf upward and 20 psf lateral Max Module Size 25.6 sq. ft. Maximum Cantilever 1/3 of span Maximum Span 6 ft Landscape, 4 ft Portrait Multiple use Rated Components (Position Independent) RockIt Mount, RockIt Coupling & MLPE Module Mount Conforms to UL SUBJECT 2703A Smart Slide on Steep Slope Asphalt Shingle Roof *Class A System fire rating with Steep and Low Slope Roofs and Type 1, 2, and 29 PV modules with no skirt required. Class A System fire rating with Steep Slope Roofs and Type 4 and 5 modules with south edge skirt required. Any roof-to-module gap is permitted. This rating is applicable with any roof attachment. **Class B System fire rating with Steep Slope Roofs and Type 4 and 5 modules, no skirt required. Any roof-to-module gap is permitted. This rating is applicable with any roof attachment. ***Mounts and couplings cannot be installed on module frames with flanges less than 22mm wide UL 2703 MARKING EXAMPLE: ROCKIT SYSTEM MFG ID CODE: SSS-QQ-YYYY XXXXXXX Conforms to UL STD 2703 TORQUE SPECIFICATIONS Component Torque (in-lb) Smart Screws N/A Mount 200 Coupling 200 Steel Slide Screw N/A MLPE Module Mount 144 Ground Lug N/A RockIt Pedestal Screw 150 RATINGS RATINGS Notes Fully Seat. Use visual indicator of the black EPDM ring around the bonded washer for torquing. Fully Seat. Use visual indicator of the black EPDM ring around the bonded washer for torquing. Refer to specific ground lug manufacturer’s installation manual System components should be periodically re-inspected for loose components, loose fasteners, and corrosion such that if found, the affected components are to be immediately replaced. PAGE 05 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE SLIDE PLACEMENT N N N STRUCTURAL ATTACHMENT POINTS • Find the required structural attachment points. S S S Max 48’ Max 72’ • Spacing may vary depending upon project specific structural requirements: i.e. high snow and wind load areas may require lesser bracket spacing in the East-West axis vs. the maximum spacing. • Max spacing is 48" OC for portrait orientation and 72" OC for landscape orientation. • Consult project layout diagram for project specific slide spacing on the roof. • Install slides to predetermined mount spacing. ARRAY SKIRT SECTIONS • Use the array skirt as a guide to lay out module placement. ROW SPACING • The distance between the rows of mounts is Array Skirt Array Skirt calculated by the module dimension NorthSouth plus 1 5/16". PLACEMENT SLIDE SPACING Y X PAGE Distance Between Rows = Y + 1 5/16" Distance Between Rows = X + 1 5/16" 06 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE SLIDE PLACEMENT LAYOUT WITH STAGGERED SLIDES • To reduce the load on an individual rafter, slides can be mounted in a staggered configuration RockIt Mount RockIt Coupling CANTILEVER & OFFSET • CANTILEVER: Maximum cantilever is Cantilever 1/3 attachment spacing. • OFFSET: Offset from all roof edges depends on wind speed, snow loads, local fire and building codes per location. PLACEMENT • Reference each project layout Offset PAGE 7 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE COMP SHINGLE INSTALLATION COMP SLIDE & FLASHING 1 1 SNAP LINES Snap chalk lines based on module dims + 1 5/16” spacing and then locate rafters PILOT HOLE Drill a 7/32" pilot hole into the rafter or structural member for the lag screw. Backfill with sealant compatible with the roof type. 2 3 CUT SHINGLE (IF NECESSARY) To position the slide in the correct location, it is acceptable to cut out a portion of the shingle 4 INSERT LAG BOLT • Line up pilot hole with flashing hole. • Using only the EcoFasten provided lag screw*, insert the lag through the RockIt Comp Slide, the 3 gasketed hole in the flashing and into the rafter. Position the slide with the date stamp facing south. • Torque: The range is between 100-140 inchpounds depending on the type of wood and time of year. The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an impact wrench to 4 install the fasteners be careful not to over torque INSTALLATION 2 the fastener. You may need to stop and use a ratchet to finish the install. * It is important to only use the lag screws provided by EcoFasten because they have longer thread lengths to increase the pull-out force PAGE 8 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE COMP SHINGLE INSTALLATION SMART SLIDE Use the shingle overlap as your starting position to snap your first chalk line (See image below). We recommend snapping chalk lines at every row to make sure every installation is completed with confidence and easy. After chalk lines have been snapped for each row, being as precise as possible, locate the rafters within the array making sure to follow the span chart and cantilevers. NOTE: For landscape module orientation, the north-south distance between each chalk line is equal to the module width plus 1-5/16". For portrait, the distance is the module length plus 1-5/16". Figure 1 PLACING THE SLIDE Once the general location of each rafter is marked, clean the mounting location with a nylon brush for proper sealing. Before peeling off the release liners, please note the Smart Slide is designed to straddle the two shingle courses. It is important to make sure the bottom foot is flush and pushed up against the shingle course edge above (see figure 1). When you locate the rafter, peel off the two release liners and place the center of the slide over the rafter. INSTALLATION ARRAY POSITIONING NOTE: Only install on clean roofs free of snow , ice and debris in ambient temperatures between 5º F and 118º F. If installing on Presidential shingles of rare thickness over 1/8”, cut off the shingle tabs to ensure the slide lies flat. PAGE 9 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE COMP SHINGLE INSTALLATION SMART SLIDE SCREW PLACEMENT & DRIVING THE SCREWS Do not remove any screws that have missed the rafter. Smart Slide is designed to give the installer multiple opportunities to find the rafter making installation quick. EPDM TORQUE GUIDE CORRECT LEVEL INCORRECT TILTED INCORRECT INCORRECT NOT ENOUGH TORQUE TOO MUCH TORQUE* INSTALLATION NOTE: Once the slide is in position, it will be difficult to remove cleanly without leaving any sealant on the roof. When rafter mounting, for any screws that miss the rafter, do not remove those screws. Smart Slide is designed to give the installer multiple opportunities to find the rafter. * If too much torque is used it could damage the EPDM washer. Damaged or blown out EPDM washers should be replaced with a new washer as needed. PAGE 10 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE COMP SHINGLE INSTALLATION SMART SLIDE SCREW PLACEMENT - DECK MOUNTED INSTALLATION When installing direct to the roof deck without regard to rafter locations, all 8 screws must be installed. (Be sure to reference the direct to deck span tables.) 2. INSTALLATION – SECOND ATTEMPT If the rafter is missed with the first screw as shown below with a red circle, drive a second screw through Hold C. If the rafter is hit with the second screw, the third screw can immediately be driven through Hole G. HOLE DESIGNATIONS FIRST ATTEMPT 1 A B C SECOND ATTEMPT 1 D 2 RAFTER RAFTER HIT RAFTER MISS # 2 E F G H ATTEMPT NUMBER INSTALLATION SCREW PLACEMENT - RAFTER MOUNTED 1. INSTALLATION – FIRST ATTEMPT Drive screw in Hole B.If a rafter is hit with the first screw, the second screw can immediately be driven through Hole F. No additional screws are needed if the first 2 screws hit the rafter. 3 PAGE NOTE: If a rafter is missed completely within the slide, you must add another slide to the previous rafter. 11 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE COMP SHINGLE INSTALLATION SMART SLIDE SCREW PLACEMENT THIRD ATTEMPT RAFTER RAFTER HIT RAFTER MISS 4. INSTALLATION – FOURTH ATTEMPT If the rafter is missed completely within the slide, you must add another slide to the previous rafter. You may then continue with your job specific attachement spans. FOURTH ATTEMPT INSTALLATION 3. INSTALLATION – THIRD ATTEMPT If the rafter is missed in both Holes B & C, then try Hole A and Hole D. If a rafter is hit through either of those holes, all 8 screws must be installed. PAGE 12 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE COMP SHINGLE INSTALLATION SMART SLIDE 1 SHINGLE BUTT JOINT* 2 SHINGLE STEP 3 SHINGLE COURSE 1 2 *Composition shingles either come in 36” or 1M length sheets. a butt joint is Where two adjacent sheets come together in a course. 3 SHINGLE BUTT JOINTS Apply a bead of roof sealant over any exposed shingle butt joints north (upslope) of a mounting foot. Please reference our approved sealant list posted on our website. INSTALLATION COMPOSITION SHINGLE INFORMATION PAGE 13 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE SYSTEM INSTALLATION 1 MOUNTS & ALIGNMENT • Begin with the row that will get Skirt which is usually the far south row. On the far east and far west Slides, install a Mount about ½” from the south end of the Slide. • Tighten side bolts to 200 in-lbs. • Run a string line across the north edge of the base of the two Mounts. • Add a Mount to each of the other Slides, position them up against the string line, and tighten the side bolts to 200 in-bs. 2 2 SKIRT POSITION • Rotate the top of the Mount so that the long, stepped shelf is facing north. Depending on the PV module thickness, use the appropriate A, B, or C Skirt. • Set the Skirt on the south side of the Mount as shown. TOP POSITION 40MM A SKIRT 38MM B SKIRT CHANNEL POSITION 35MM A SKIRT 32MM B SKIRT 3 NOTE: There are ridges inside the small channel on the B Skirt whereas the channel is smooth on the A Skirt. 3 SKIRT TIGHTENING Tighten top bolt in Mount to secure the Skirt 4 4 SKIRTS END CAPS INSTALLATION 1 Press fit End Caps at every Skirt connection and on the ends. NOTE: The End Caps makes it easier to align the Skirts and is required for strength. PAGE 14 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE SYSTEM INSTALLATION 5 5 COUPLINGS ON SKIRTS • Everywhere two modules will meet, install a Coupling on the Skirt with the long, stepped shelf facing north. NOTE: There must be at least one Mount or one Coupling connecting every Skirt section. 6 6 ALIGN & STRAIGHTEN SKIRTS (OPTIONAL) • If the row of Skirts is not straight in the north-south direction, loosen appropriate side bolts, slide the Mount and retighten to 200 in-lbs • If the row of Skirts is not straight in the up-down direction, adjust the leveling nut inside the Mount • Align skirts with module edge 7 7 INSTALL FIRST ROW OF PV MODULES • Place the modules into the first row of Mounts and Couplings at a 45 degree angle. While applying pressure against the Mounts and Couplings, lower the modules until parallel to the roof ensuring the modules are fully seated. • Space the modules in the east/west direction ½” to ¾”. INSTALLATION • Torque to 200 in-lbs. PAGE 15 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE SYSTEM INSTALLATION 9 9 INSTALL SECOND ROW OF COUPLINGS • At the intersection of the north side of two modules, install a Coupling with the two bonding pins facing south. running into a Mount, but the two bonding pins must clamp different modules. • Torque to 200 in-lbs. 10 10 INSTALL SECOND ROW OF MOUNTS • Lift the modules slightly and install the Mounts on the Slides to engage the north side of the module. • Tighten to 200 in-lbs. 11 11 LEVELING (OPTIONAL) & WIRE MANAGEMENT • Before installing next row of modules, level the row (if needed) by turning the leveling nut. • Manage wires after each row of modules is installed (see Tips & Tricks video on wire management on the EcoFasten website) 12 COMPLETE THE ARRAY Repeat steps above for all other rows in the array. INSTALLATION • Coupling can be positioned off center to avoid PAGE 16 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE OTHER INSTALLATION OPTIONS SUPPLIMENTAL GUIDES TILE MOUNTING SYSTEM INSTALLATION SIMPLEBLOCK-U INSTALLATION Click here to view guide SIMPLEGRIP INSTALLATION Click here to view guide TILE CONDUIT MOUNT INSTALLATION Click here to view guide CONDUIT MOUNT INSTALLATION Click here to view guide ACCESSORIES FRAME MLPE INSTALLATION Click here to view guide J-BOX INSTALLATION Click here to view guide SUPPLIMENTALS ROOF ATTACHMENTS Click here to view guide PAGE 17 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE OTHER INSTALLATION OPTION METAL ROOFS 1 1 EAST-WEST ROOF MARKING Snap horizontal lines to mark the installation position for each row of Steel Slides. For landscape module orientation, the North-South distance between each chalk line is equal to the module width plus 1 5/16". For portrait, the distance is the module length plus 1 5/16". 2 2 STEEL SLIDE POSITIONING Position the Steel Slides over the chalk lines and over the center of the flat peaks of the metal roof ribs. 3 STEEL SLIDE FASTENING Using only the screws provide by EcoFasten, drive 4 screws through the holes in the Steel Slide an into the rook panel. Use a ¼" socket with a 2" extension. 3 *A WATERTIGHT SEAL HAS BEEN FORMED WHEN THE RUBBER ON THE WASHER CREATES A VISIBLE RING AROUND THE SCREW HEAD. CORRECT LEVEL INCORRECT TILTED INCORRECT INCORRECT NOT ENOUGH TORQUE TOO MUCH TORQUE* * If too much torque is used it could damage the EPDM washer. Damaged or blown out EPDM washers should be replaced with a new washer as needed. INSTALLATION The RockIt Steel Slide can be installed on steel trapezoidal, R-panel or PBR roof panels that are at least 26 gage thick and have a flat peak of at least 1/4" wide. They fasten directly to the metal deck without the need to attach to any substructure. PAGE 18 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE BONDING AND GROUNDING THERMAL EXPANSION & BONDING • A thermal expansion gap is required per each continuous 70' length of modules. in the RockIt array skirt and also between the modules at that point. • Bonding across the thermal gap should be accomplished with an approved ground lug for each array and an equipment grounding Bonding Path Direction HARDWARE Grounding Lug RockIt Coupling conductor. RockIt Mount RockIt Skirt Equipment Grounding Conductor (EGC) Skirt Bonding Path BONDING PATH & ASSEMBLY • RockIt mount bonds North-South rows of modules. • RockIt coupling bonds East-West rows of modules. • RockIt array skirt is bonded to the array via the RockIt mount. GROUNDING • Omit a coupling and leave a 2" gap • One approved ground lug is required per continuous PV array. • Ilsco SGB-4 Approved for Mounting to Rockit Mount or Rockit Slides as Bonding Path Direction HARDWARE Grounding Lug RockIt Coupling RockIt Mount RockIt Skirt alternate grounding location Equipment Grounding Conductor (EGC) Skirt Bonding Path PAGE 19 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE BONDING AND GROUNDING NECESSARY COMPONENTS One of the following grounding lugs (or any UL 2703 Compliant ground Lug): • Burndy CL50-1TN Ground Lug (UL2703 - E3514343 / UL 467 E9999) • ILSCO GBL-4DBT (UL2703 E354420 / UL 467 - E34440) • ILSCO GBL-4DBTH (UL2703 E354420 / UL 467 - E34440) • ILSCO GBL-4SS (UL2703 - E354420 / UL 467 - E34440) GROUNDING • ILSCO SGB-4 Ground Lug (UL2703 E354420/ UL 467 - E34440) Above: Optional Locations for grounding lug on last row upslope of array *Equipment grounding wire should be sized in accordance with the National Electrical Code, NFPA70 and a minimum of 1/4" clearance is required between bare copper wires and aluminum components. PAGE 20 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE COMPATIBLE MODULES The Rockit System has been tested and evaluated to UL 2703 for bonding, grounding, mechanical loading and fire classification, and may be used to ground and/or mount PV modules listed to UL 1703 or UL 61730. A list of approved modules is included below. Unless otherwise noted, “xxx” refers to the module power rating and both black and silver frames are included in the certification. *Class A System fire rating with Steep and Low Slope roofs and Type 1, 2, and 29 PV modules with no skirt required. TYPE 1, 2 & 29 MODULES MANUFACTURER LIST OF UL 2703 APPROVED TYPE 1, 2 & 29 PV MODULES* Adani modules with 35 and 40 mm frames Adani ASX-Y-ZZ-xxx Where “X” can be B, M or P, “Y” can be 6 or 7, and “ZZ” can be blank, PERC, B-PERC, or AB-PERC Aionrise modules with 35 and 40 mm frames AIONRISE AIONyyG1-xxx Where “yy” can be 60 or 72 Aptos modules with 35 and 40 mm frames Aptos Solar DNA-yy-zzaa-xxx Where “yy” can be 108, 120 or 144; “zz” can be MF or BF; and “aa” can be 10, 23 or 26 Astronergy modules with 35 and 40 mm frames Astronergy Solar CHSMbbyyC/zz-xxx MODULES NOTE: Modules with flange widths shorter than 22mm cannot be installed in portrait. Where “bb” can be 60, 66, or 72; “yy” can be blank, 10 or 12; “C” can be M, M(BL), M-HC, P, P(BL) or P-HC ; and “zz” can be blank or HV Auxin modules with 40 mm frames Auxin AXNYMzYYMxxxB Where “Y” can be 6 , 10 or G1; “z” can be blank or 6; “YY” can be blank, 10 or 12; “B” can be blank, A, B, C or W Axitec Modules with 30 and 35 mm frames Axitec AC-xxxY/aaZZ “Y” can be M, P, MH or MBT; and “aa” can be blank, 125 or 156; and “ZZ” can be 60S, 108V, 108VB, 120S, 120V or 120VB PAGE 21 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE MANUFACTURER LIST OF UL 2703 APPROVED TYPE 1, 2 & 29 PV MODULES* Bluesun modules with 30 and 35 mm frames Bluesun Solar BSMxxxM-AAA Where “AAA” can be 60HPH or 72HBD Boviet modules with 35 and 40 mm frames Boviet BVM66aaYY-xxxBcc Where “aa” can be 9, 10 or 12; “YY” is M, or P; and “B” can be blank, L or S; and “cc” can be blank, H, H-BF, H-HC or HC-BF Canadian Solar modules with 35 and 40 mm frames Canadian Solar CSbY-xxxZ Where “b” can be 1, 3 or 6; “Y” can be H, K, L, N, P, R, V or Y; and “Z” can be M, MS, M-SD, MS-HL, MS-SD, P, PX, or P-SD CertainTeed CTBBxxxYZZ-AA Where “BB” can be blank or M10; “Y” can be M or HC; “ZZ” can be 00, 10 or 11; and “AA” can be 04, 06, 08 or 09 Crossroads Solar Crossroads Solar modules with 40 mm frames Crossroads Solar xxx CSUN modules with 35 and 40 mm frames CSUN CSUNxxx-zzAbb Where “zz” is 60 or 72; and “A” is M or MM; “bb” is blank or 5BB Dehui modules with 35 and 40 mm frames Dehui DH-MYYYZ-xxx Where “YYY” can be 760, 772, 860, 872; and “Z” can be B or W ET Solar modules with 35 and 40 mm frames ET-YZZZxxxAA ET Solar Where “Y” can be P, L, or M; “ZZZ” can be 660, 660BH, 672, 672BH, or 754BH; and “AA” can be TB, TW, WB, WW, BB, WBG, WWG, WBAC, WBCO, WWCO, WWBCO or BBAC MODULES CertainTeed modules with 30, 35 and 40 mm frames Freedom Forever modules with 35 mm frames Freedom Forever FF-MPa-BBB-xxx Where “a” can be blank or 1 Freevolt Goldi Grape Solar Freevolt modules with 35 mm frames ECP-PVGRAF-144HC-xxx Goldi modules with 35 mm frames GS10-B108-TF-xxx Grape modules with 35 mm frames GS-M120-xxx-FAB1 PAGE 22 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE MANUFACTURER LIST OF UL 2703 APPROVED TYPE 1, 2 & 29 PV MODULES* Hanwha Q CELLS Modules with 32, 35 and 40 mm frames aaYY-ZZ-xxx where “aa” can be Q. or B.; “YY” can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS, PLUS DUO or PEAK DUO; and “ZZ” can be G3, G3.1, G4, G4.1, L-G2, L-G2.3, L-G3, L-G3.1, L-G3y, L-G4, L-G4.2, L-G4y, LG4.2/TAA, BFR-G3, BLK-G3, BFR-G3.1, BLK-G3.1, BFR-G4, BFR-G4.1, BFR G4.3, BLK-G4.1, G4/SC, G4.1/ Hanwha Q CELLS SC, G4.1/TAA, G4.1/MAX, BFR G4.1/TAA, BFR G4.1/MAX, BLK G4.1/TAA, BLK G4.1/SC, EC-G4.4, G5, G5/SC, G5/TS, BLK-G5, BLK-G5/SC, BLK-G5/TS, L-G5, L-G5.1, L-G5.2, L-G5.2/H, L-G5.3, G6, G6/SC, G6/TS, G6+, G6+/TS, BLK-G6, G7, BLK-G6+, BLK-G6+/AC, BLK-G6+/HL, BLK-G6+/SC, BLK-G6/TS, BLK-G6+/TS, BLK-G7, G7.2, G8, BLK-G8, G8+, BLK-G8+ L-G7, L-G7.1, L-G7.2, L-G7.3, BLK ML-G10, ML-G10+, BLK ML-G10+, ML-G10.a, BLK ML-G10.a, ML-G10.a+, BLK ML-G10.a+, BLK ML-G10 +/t and BLK ML-G10+/TS Heliene modules with 35 and 40 mm frames Heliene YYZZxxxA Where “YY” can be 60, 72, 108 or 120; “ZZ” can be HC, M or P; and “A” can be blank, M10-SL, M10-SL-BLK or M10-SL-Bifacial HT-SAAE modules with 35 and 40 mm frames HT-SAAE HTyy-aaaZ-xxx Where “yy” can be 60 or 72, “aaa” can be 156 or 166, “Z” can be M, M(V), M(S), M(VS), M-C, M(V)-C, P or P(V) Hyperion Solar (Runergy) Hyperion modules with 35 mm frames HY-DH108Y8-xxxB Where “Y” can be N or P; and “B” can be blank or B Huyndai modules with 32, 35 and 40 mm frames Hyundai HiY-SxxxZZ Where “Y” can be A or S; “S” can be M or S; and “ZZ” can be HG, KI, MF, MG, MODULES ML-G9, ML-G9+, BLK ML-G9+, ML-G9, BLK-G10+, BLK-G10+/AC, ML-G10, BLK PI, SG, RG, RG (BK), TG or YH(BK) or XG(BK) Itek Modules with 40 mm frames Itek IT-xxx-YY “YY” can be blank, HE, or SE PAGE 23 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE MANUFACTURER LIST OF UL 2703 APPROVED TYPE 1, 2 & 29 PV MODULES* JA Solar modules with 30, 35 and 40 mm frames JAyyzz-bbww-xxx/aa Where “yy” can be M, P, M6 or P6; “zz” can be blank, (K), (L), (R), (V), (BK), (FA), JA Solar (SE), (TG), (FA)(R), (K)(SE), (K)(TG), (L)(BK), (L)(TG), (R)(BK), (R)(TG), (V)(BK), (BK) (TG), or (L)(BK)(TG); “bb” can be 54, 60 or 72; “ww” can be blank, D30, S01, S02, S03, S09, S10, S17, S30 or S31; and “aa” can be MR, SI, SC, PR, RE, 3BB, 4BB, 4BB/RE, 4BB/1500V, PR/1500V, 5BB Jinko modules with 35 and 40 mm frames JKMYxxxZZ-aa Jinko Where “Y” can either be blank or S; “ZZ” can be M, P, PP, or -V; and “aa” can be blank, 60, 60B, 60H, 60HB, 60L, 60BL, 60HL, 60HBL, 60-J4, 60B-J4, 60Bor 6TL3-B LG modules with 40 mm frames LG LGxxxyaz-bb “y” can be A, E, M, N, Q, or S; “a” can be A, 1, 2 or 3; “z” can be C, K or W; and “bb” can be G4, A5, A6, B6, E6, E6.AW5, L5, N5, v5, V6 Longi modules with 35 and 40 mm frames Longi LRa-YYZZ-xxxM Where “a” can be 4, 5 or 6; “YY” can be 54, 60 or 66 “ZZ” can be blank, BK, PB, PE, PH, HPB, or HPH Maxeon modules with 35, 40 and 46 mm frames Maxeon SPR-AAAY-xxx-zzz Where “AAA” can be MAX or X; “Y” can be 3, 5, 6, 21 or 22; and “zzz” can be R, BLK or COM Meyer Burger Meyer Burger Modules with 35 mm frames Meyer Burger Black, White or Glass Mission Solar modules with 35, 40 mm frames Mission Solar (mSolar) MODULES EP, 60(Plus), 60-V, 60-MX, 72H, 72H-V, 72HL-V, 72HBL-V, 72L-V, 6RL3, 6RL3-B YYYbb-xxxZZaa Where “YYY” can be MSE, TXI or TXS; “bb” can be blank, 6, 10 or 60A; “ZZ” can be blank, SO, SQ, SX, 108, 120 or 144; and “aa” can be blank, BB, BW, 4J, 4S, 5K, 5R, 5T, 8T, 8K, 9R or 9Z Mitrex modules with 30, 35 and 40 mm frames Mitrex Mxxx-XYZ Where “X” can be A, B, I or L; “Y” can be 1 or 3; and “Z” can be F or H PAGE 24 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE MANUFACTURER Next Energy Alliance LIST OF UL 2703 APPROVED TYPE 1, 2 & 29 PV MODULES* Next Energy Alliance modules with 35 and 40 mm frames yyNEA-xxxZZ where “yy” can be blank or US; “ZZ” can be M, MB or M-60 NE Solar modules with 30, 35 and 40 mm frames NE Solar NESExxx-zzMHX-yy Where “zz” can be 54, 60 or 72; “X” can be blank or B; and “yy” can be M6 or M10 Panasonic modules with 40 mm frames Panasonic (HIT) VBHNxxxYYzzA “YY” can be either SA or KA; “zz” can be either 03, 04, 17 or 18; and “A” can be blank, E or G Panasonic modules with 30 mm frames EVPVxxxA Where “A” can be blank or H, K, HK or PK Philadelphia modules with 30, 35 and 40 mm frames Philadelphia Solar PS-YzzAA-xxxW Where “Y” can be M or P; “zz” can be 60, 72, 108 or 144; “AA” can be blank, (BF), (HC) or (HCBF); and “W” can be blank or W Phono Solar modules with 30 and 35 mm frames Phono Solar PSxxxY-ZZ/A Where “Y” can be M4, M4H, M5GF, M5GFH, M6, M6H, M8GF or M8GFH; “ZZ” can be 18, 20 or 24; and “A” can be TH, UHB, VH or VHB Prism Solar modules with 35 mm frames Prism Solar PST-xxxW-M72Y Where “Y” can be H, HB or HBI REC modules with 30 and 38 mm frames RECxxxYYZZ REC Where “YY” can be AA, M, NP, NP2, NP3, PE, PE72, TP, TP2, TP2M, TP2SM, MODULES Panasonic (EverVolt) TP2S, TP3M or TP4; and “ZZ” can be blank, Black, BLK, BLK2, SLV, 72, Pure or Pure-R Recom modules with 35 and 40 mm frames Recom RCM-xxx-6yy Where “yy” can be MA, MB, ME or MF ReneSola 60-cell modules with 40 mm frames Renesola JCxxxY-ZZ “Y” can be F, M or S; and “ZZ” can be Ab, Ab-b, Abh, Abh-b, Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, or Db-b PAGE 25 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE MANUFACTURER LIST OF UL 2703 APPROVED TYPE 1, 2 & 29 PV MODULES* Renogy Modules with 35 mm frames Renogy RSPxxxD-YY-ZZZ Where “YY” can be BB or BK; and “ZZZ” can be 108 or 120 S-Energy modules with 35 and 40 mm frames SABB-CCYYY-xxxZ S-Energy Where “A” can be C, L or N; “BB” can be blank, 20, 40 or 45; “CC” can be blank, 60 or 72; “YYY” can be blank, MAE, MAI, MBE, MBI, MCE or MCI; and “Z” can be V, M-10, P-10 or P-15 Seraphim modules with 35 and 40 mm frames Seraphim USA SRP-xxx-YYY-ZZ Where “YYY” can be 6MA, 6MB, 6PA, 6PB, or BMD; “ZZ” is blank or HV SEG Solar SEG-xxx-YYY-ZZ Where “YYY” can be BMB, BMD or 6MA; “ZZ” can be BB, BW, HV, TB, WB or WW Shinsung E&G Shinsung Modules with 35 mm frames SSVxxx-144MH Silfab Modules with 35 and 38 mm frames Silfab SYY-Z-xxxAb Where “YY” can be IL, SA, LA, SG or LG; “Z” can be blank, M, P, or X; “A” can be blank, B, H, M, N; and “b” can be A, C, C+, G, K, L, M, N, T, U or X Solar4America modules with 30, 35 and 40 mm frames Solar4America S4Axxx-ZZyyAA Where “ZZ” can be 72 or 108; “yy” can be MH5 or MH10; and “AA” can be BB or SW Solarever modules with 35 mm frames Solarever SE-zzz*yy-xxxM-aaa Where “zzz” can be 166 or 182; “yy” can be 83 or 91; and “aaa” can be 108 or MODULES SEG Solar Modules with 35 and 40 mm frames 144 Solaria modules with 35 and 40 mm frames Solaria PowerA-xxxR-ZZ Where “A” can be XT or X; and “ZZ” can be blank, AC, BD, BX, BY, PD, PL, PX, PZ, WX or WZ SolarTech modules with 40 mm frames SolarTech AAA-xxx Where “AAA” can be PERCB-B, PERCB-W, HJTB-B or HJTB-W PAGE 26 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE MANUFACTURER Sonali LIST OF UL 2703 APPROVED TYPE 1, 2 & 29 PV MODULES* Sonali Modules with 35 mm frames SS-M-xxx Star Solar modules with 35 mm frames Star Solar Star-xxxYYY-ZZZ Where “YYY” can be M60H or M60HB; and “ZZZ” can be blank or M10 Sunmac modules with 30 and 35 mm frames Sunmac Solar SMxxxMaaaZZ-BB Where “aaa” can be 660 or 754; and “ZZ” can be NH or SH Sunpower modules with 35 and 40 mm frames Sunpower SPR-A-xxx-YY Where “A” can be A or M; and “YY” can be blank , COM, G-AC, BLK-G-AC, Sunpreme Sunpreme Modules with 40 mm frames GxB-xxxT Sunspark modules with 40 mm frames Sunspark SYY-xxxZ-A Where “YY” can be MX or ST; and “Z” can be M, MB, M3, M3B, P or W; and “A” can be 60 or 72 Suntech Modules with 35 mm frames Suntech STPxxxS-zz/aa Where “zz” can be B60 or B72; and “aa” can be Vnh or Wnhb Talesun modules with 30 and 35 mm frames Talesun TD6yZZA-xxx Where “D” can be D or P; “y” can be G, I or L; “ZZ” can be 60 or 72; and “A” can be M or M(H) Tesla modules with 40 mm frames Tesla TxxxY Where “Y” can be H or S Thornova Modules with 30 and 35 mm frames Thornova MODULES H-AC or BLK-H-AC TS-YYZZ(xxx)-X Where “YY” can be BB or BG; “ZZ” can be 54 or 60; and “X” can be blank or X Trina modules with 30, 35 and 40 mm frames TSM-xxxYYZZ Trina “YY” can be DD05, DD05A, DD06, DE05, DE09, DX05A, DE06X, PA05, PC05, PD05, PE14 or PX05; and “ZZ” can be blank or A, .05, .05(II), .08, A.05, A.08, A(II), A.05(II), A.08(II), C.05, C.07, C.05(II), C.07(II), H, H.05, H.08, H.05(II), H.08 (II), M, M(II) or M.05(II) PAGE 27 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE MANUFACTURER LIST OF UL 2703 APPROVED TYPE 1, 2 & 29 PV MODULES* Universal Solar Modules with 35 mm frames Universal UNI-xxx-yyyZZZ-aa Where “yyy” can be 108, 120 or 144; “ZZZ” can be M, MH or BMH; and “aa” can be blank, BB or DG URE modules with 35 mm frames URE DyMxxxaa Where “D” can be D or F, “y” can be A, B, 6 or 7; “M” can be K, or M; and “aa” can be C8G, H3A, H4A, H8A, E7G-BB, MFG-BB or M7G-BB Vikram solar modules with 35 and 40 mm frames XVSyy.ZZ.AAA.bb Where “X” can be blank, Paradea, Prexos or Somera; “yy” can be MDH, MDHT, MH or MHBB; “ZZ” can be 54, 60 or 72; “AAA” is the module power rating; and “bb” can be 05 VSUN modules with 30, 35 and 40 mm frames VSUN VSUNxxx-YYz-aa Where “YY” can be 108 or 120; “z” can be BMH or M; and “aa” can be blank, BB or BW Waaree modules with 40 mm frames Waaree WSyy-xxx where “yy” can be blank, M or MB Yingli modules with 30, 35 and 40 mm frames Yingli YLxxxZ-yy Where “Z” can be D or P; “yy” can be blank, 29b, 30b, 34d, 35b, 36b, 37e 1/2, 37e 1500V 1/2, 40d, 49e 1/2 or 49e 1500V 1/2 Yotta Zeus Yotta modules with 30 mm frames YSM-Bxxx-06-72-1 Zeus Solar Modules with 40 mm frames ZxxxM-HB MODULES Vikram ZN Shine modules with 35 mm frames ZN Shine ZXMY-AAA-xxx/M Where “Y” can be 6 or 7; “AAA” can be 72, NH120, NHDB144 or SH108 PAGE 28 REVISION DATE: 06/28/23 VERSION: v3.3 INSTALLATION GUIDE TYPE 4 MODULES **Class A System fire rating with Steep Slope Roofs and Type 4 modules with south edge skirt required. Class B System fire rating with Steep Slope Roofs Type 4 modules, no skirt required. Any roof-to-module gap is permitted. This rating is applicable with any roof attachment. MANUFACTURER Bluesun Solar LIST OF UL 2703 APPROVED TYPE 4 PV MODULES** Bluesun modules with 35 mm frames BSMxxxM10-54HPH Emmvee modules with 35 mm frames Emmvee Exxx-YYZZZ-B Saatvik Modules with 35 mm frames Saatvik SGExxx-108ZZZ Where “ZZZ” can be MHC, MBHC or MHCB Sirius PV Solarever Talesun Sirius PV Modules with 35 mm frames ELNSM54M-HC-xxx Solarever modules with 35 mm frames SE-166*83-450M-144N Talesun modules with 30 mm frames TP7G54M(H)xxx MODULES Where “YY” can be M, P and HCM; “ZZZ” can be 72 or 120 PAGE 29 ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Patented Watertight Technology
- Fully integrated bonding
- Top-down leveling system
- North-South adjustability
- Single tool install
Frequently asked questions
1500V
40A
25.6 sq. ft.
1/3 of span
6 ft Landscape, 4 ft Portrait