Owner Instructions
Warning!
Read instructions before using the machine
WVD 570 (Cyclonic Entry)
WVD 900 (Cyclonic Entry)
WVD 900 DH (Cyclonic Entry, Dump Hose)
www.numatic.com
607241 Kit BS8
For extra tools see our
NUMATIC INTERNATIONAL CleanCare catalogue
or
Discuss your specific kit requirements with
Numatic Specialised Department.
01460 269401
Assembly
1
Assemble wands.
2
3
Check blanking cap is fitted to the middle
hose flange.
Fit the hose to the side entry.
900 Handle Assembly
X4
X4
Cleaning the machine (WET)
1
2
WVD 570
1
2
3
2
3
WVD 900
1
WVD 900 DH
(Dump Hose)
Cleaning the machine (DRY)
1
3
2
WVD 570
NVM - 3BH
WVD 900
NVM - 4BH
1
2
3
4
5
6
7
8
About the Machine
1
2
3
4
5
6
7
8
9
Company Name & Address
Model
1
2
Voltage
3
4
Frequency
Rated Input Power
Weight (ready to work)
Protection Class Symbol
WEEE Logo
Safety Critical Components
5
6
CE Mark
Mains lead
10 Machine yr/wk Serial number
7
8
H05VVF 10m x 1.5 x 2core
9
10
PPE
Personal protective equipment that may be required for certain operations.
Ear Protection
Dust / Allergens
Protection
Safety Footwear Head Protection
Eye Protection
Protective
Clothing
Safety Gloves
Caution
Floorsign
Hi Viz Jacket
NOTE:
A risk assessment should be conducted to determine which PPE should be worn.
WEEE Legislation
(Waste, Electrical and Electronic Equipment)
Vacuum cleaner, accessories and packaging should be sorted for environmentally friendly recycling.
(Only for EU Countries)
Do not dispose of vacuum cleaner into household waste! According to
the European Directive 2012/19/EU on waste electrical and electronic
equipment and its incorporation into national law.
Vacuum cleaners that are no longer suitable for use must be separately
collected and sent for recovery in an environmentally - friendly manner.
Failure to rectify the problem or in the event of a breakdown contact your Numatic dealer
or the Numatic Technical helpline +44 (0)1460 269268.
Daily
Keep the machine clean, including hoses and tubes.
Ensure the bag and filter are fitted.
Regularly examine the power cord.
Check dust bag frequently.
Check filters are clean.
Weekly - as daily and:Check for any worn or damaged parts and replace immediately.
Do not steam clean or pressure wash.
DATA / WVD 570
Motor
AirFlo
Suction
Cleaning
Range
Class
2400W
76 L/sec
2400 mm w.g.
26.8m
II
Capacity
Wet
Size
Weight
Sound Pressure
15 Ltrs
415x415x645
15.8 Kgs
73.6-79 dB (IEC 60704-2-1)
Uncertainty: 0.2 dB (A)
DATA / WVD 900 / WVD 900DH
Motor
AirFlo
Suction
Cleaning
Range
Class
2400W
76 L/sec
2400 mm w.g.
26.8m
II
Capacity
Wet
Size
Weight
Sound Pressure
32 Ltrs
800x490x880
25.0 Kgs
73.6-79 dB (IEC 60704-2-1)
Uncertainty: 0.2 dB (A)
Information for WET & DRY use vacuum cleaners
WARNING
Read the instruction manual before using the machine.
Operators shall be adequately instructed on the use of these machines.
As with all electrical equipment, care and attention must be exercised at all times during use,
in addition to ensuring that routine and preventative maintenance is carried out periodically
to ensure safe operation.
Failure to carry out maintenance as necessary, including the replacement of parts to the
correct standard could render this equipment unsafe and the manufacturer can accept no
responsibility in this respect.
The machine shall be disconnected from the mains by removing the plug from the supply
socket during cleaning or maintenance and when replacing parts or converting the machine
to another function.
The machine is not to be used by children or persons with reduced physical, sensory or
mental capabilities, or lack of experience or knowledge, unless they have been given
supervision or instruction
Children being supervised are NOT to play with the machine.
This appliance is intended to be assembled, cleaned and maintained by an adult.
This machine is not a toy.
Only use the socket outlet on the machine for purposes specified in the instructions.
CAUTION!
If foam/liquid comes out of machine exhaust, switch off immediately. Allow the accumulated
liquid to drain out through the machine exhaust, check the float assembly to ensure correct
operation, empty the container if full of liquid, reassemble the machine. Immediately upon
start up there will be a certain amount of liquid issuing from the machine exhaust which will
be the residue of liquid still within the power head.
This will be quickly discharged after which the machine should function normally.
Liquid ejected from the machine could be hazardous as a result of its temperature, pressure
or chemical content.
This machine is not suitable for the collection of biological hazards, hazardous or explosive
dust.
You should contact your local distributor if you require a machine capable of performing
these tasks.
Ensure that the filtration system fitted to the machine is suitable for the material being
collected.
This machine is for indoor use only.
This machine shall be stored indoors only
This product complies with the requirements IEC 60335 -2-69.
When moving from one place to another, consider the weight of the machine.
NOTE: This machine is also suitable for commercial use, for example in hotels, schools,
hospitals, factories, shops and offices for other than normal housekeeping purposes.
DO •
Use a bag and filter at all times when using ‘dry’.
•
Keep your machine clean.
•
Keep filters clean.
•
Regularly clean the water level limiting float safety valve and examinefor signs of damage or correct operation.
•
Keep hoses and tubes clear.
•
Replace any worn or damaged parts immediately.
•
Regularly examine the power cord, if damage is found, power cord must be
replaced by a qualified person using the correct Numatic original part.
•
Empty dust container frequently.
•
Keep diffuser filter (where fitted) clean.
DON’T
•
Use steam cleaners or pressure washers to clean the machine or use the machine
in the rain.
•
Immerse in water for cleaning.
•
Allow any inexperienced repairs. Call the experts.
•
Use wet if float valve is not functioning or fitted.
•
Use to suck up hot ashes, or lighted cigarette ends.
•
Suck up liquid before emptying dirt from container.
•
Suck up dirt before emptying liquid from container.
•
Run the machine over the power cable during operation as a hazard may occur.
•
Pull on the cable to unplug the machine from the power supply.
•
Walk over-wet carpets, upholstery or fabrics.
•
Walk on clean carpets until fully dry.
•
Spray onto people or animals.
•
Attempt machine maintenance or cleaning unless the power supply plug
has been removed from the supply outlet.
This machine can be used for wet and dry pick up.
Dry Mode maintenance / fault finding
If the vacuum cleaner stops working switch off and remove the plug from the wall before
investigating where the fault lies.
If the vacuum cleaner will not pick up any debris from the surface, switch off and remove the
plug from the wall, inspect the floor tool, wands and hose for blockages, if no blockages are
found, the dust bag may be full if the dust bag is not full the filter may be blocked.
Wet mode / fault finding
If the vacuum cleaner stops working switch off and remove the plug from the wall before
investigating where the fault lies.
If the vacuum cleaner has a blockage and will not pick up liquid, switch off and remove the
plug from the wall, has the float valve operated, this will shut off the suction and the pitch
of the vacuum motor will change Remove the power head and empty the liquid out of the
container, if the container is empty, check that the floor tool wands and hose are not blocked.
After use always inspect the machine for damage.
14” WV Duplex WD-0255 (A02)
Warranty
Declaration of conformity
EU DECLARATION
OF
CONFORMITY
16
We hereby declare under our sole responsibility that the
following equipment fulfils all the relevant provisions of the
following EU Directives:
Machinery Directive 2006/42/EC
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
Machine Description:
Type: WVD, WV, CV, CVD series
Manufactured by:
Vacuum Cleaner
Numatic International Limited
Relevant standards upon which conformity is declared
include:
IEC 60335-1 2001 + A1 2004 + A2 2006 + National
Deviations
IEC 60335- 2-2 2002 + A1 +A2
IEC 60335-2.69 2002 + A2
EN 55014-1 2001 +A1 2001, +A2 2002
EN 55014-2 1997 + A1 2001 (Cat II)
EN 50366 2003 + A1 2006
A technical construction file for this equipment is retained at
the manufacturer’s address under the authorisation of the
following signatory:
Name:Allyn Boyes
Position: Technical Manager
Signed:
Date: 20/04/2016
Numatic International Limited,
Chard , Somerset.
TA20 2GB
www.numatic.co.uk
GB
Numatic International Limited, Chard, Somerset, TA20 2GB
Telephone: 01460 68600
Fax: 01460 68458
UNITED KINGDOM: www.numatic.co.uk
GERMANY: www.numatic.de
SWITZERLAND: www.numatic.ch
FRANCE: www.numatic.fr
NETHERLANDS: www.numatic.nl
SOUTH AFRICA: www.numatic.co.za
PORTUGAL: www.numatic.pt
Specification subject to change without prior notice
www.numatic.com © Numatic International Limited
904683 11/16 (A01)
">