Wells | RCP-400 | installation instructions electrical cutout details product dimensions

INSTALLATION INSTRUCTIONS
REFRIGERATED COLD PAN
MODEL RCP-400
ELECTRICAL
MODEL
VOLTS
WATTS
HP
AMPS
PHASE
FIELD
WIRING
GAUGE
TEMP.
RATING
RCP-400
115
805
1/4
7.0
SINGLE
14 AWB Cu
75°C
CUTOUT DETAILS
INCHES
(MM)
PRODUCT DIMENSIONS
23 7/8
(606)
19 7/8
(505)
14
(356)
23
(584)
53
(1346)
57
(1448)
25 3/8
(645)
POWER SUPPLY CORD
58 1/2
(1486)
3/4
(19)
8
(203)
CLEARANCES
THERE ARE NO CLEARANCE REQUIREMENTS FOR THIS UNIT.
9
(229)
18
(457)
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY
OUTLINED BELOW UPON INSTALLATION:
1. This unit may be installed in stainless steel, wood, Formica,
or Corian tables and countertops.
2. This unit is shipped completely assembled and requires
only a 15 AMP grounded outlet and drain connection. Power
cord and ON/OFF switch should be accessible after installation of the unit.
3. When installing the unit it is essential to provide
front and rear openings in the cabinet to allow for proper
air circulation. Louvered grills with a minimum size of
200 sq. inches each may be placed over each opening.
3/4
(19)
9
(229)
1
(25)
8
(203)
1/4
(6)
TO INSTALL:
1. Lay out "cutout" dimensions on countertop or table.
2. Cut out hole. Countertop must be flat and level
before installing cold pan.
3. Apply a generous bead of silicone sealant to underside of mounting flange before setting unit into cutout.
Remove any excess sealant from top flange and countertop.
4. Connect 1 inch drain to drain pan or floor drain.
Consult local codes for approved drain connections.
2 3/4
(70)
1" NPT DRAIN
CENTERED IN PAN
CROSS-SECTION OF COLD PAN
WELLS/BLOOMFIELD * VERDI, NV
49405-4 REV (-)