IP Link® Device Interface
Communication Sheet
aten_15_6277_3.pke
Revision: 3/1/2013
This document provides additional assistance with wiring your Extron IP Link enabled product to your device.
Different components may require a different wiring scheme than those listed below.
For complete operating instructions, refer to the user's manual for the specific Extron IP Link enabled product or
the controlled device manufacturer supplied documentation.
Device Specifications:
Device Type:
Manufacturer:
Firmware Version:
Model(s):
Matrix Switcher
Aten
N/A
VM1616T
Version History:
Driver
Version
Date
IP Link
Compiler
GC
Version
Notes
3
3/1/2013
1.5.1
3.3.2
Added states Local Output and All to Output command.
2
12/26/2012
1.5.1
3.3.2
Added Preset 16 – 31 and Output 11.
1
12/4/2012
1.5.1
3.3.2
Initial version.
Driver Notes:
Driver includes Volume optimization.
Page 1 of 3
IP Link® Device Interface
Communication Sheet
aten_15_6277_3.pke
Revision: 3/1/2013
Control Commands & States:
Auto Image
Execute
Device
0 – 15
Input
1 – 16
Master Output Level
0 to 15 in steps of 1
Master Output Mute
On
Off
Mute Output 1
On
Off
Output
1 – 16
Local Output
Output 1 – 16 Level
0 to 15 in steps of 1
Preset Recall
0 – 31
Preset Save
0 – 31
Take
Video
Status Available:
Audio
N /A
MLC60 Series Supported Commands:
Preset Recall
0 – 31
Preset Save
0 – 31

Preset Save and Preset Recall are set to work with address 00.
Page 2 of 3
All
aten_15_6277_3.pke
IP Link® Device Interface
Communication Sheet
Cable and Adapter Requirements:
M/F DB9 RS232 Null cable
Notes for the Device:
.
Serial communication:
Port Type: RS-232
Baud Rate: 9600
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
Pin Assignments Diagram:
Note: Captive screw connector may also be used as a serial connection.
General Notes:
Page 3 of 3
Revision: 3/1/2013