Installation
This installation guide gives step-by-step instructions about how to install the LBG1000A-R2 switch:
Selecting a Site for the LBG1000A-R2 Switch
As with any electric device, you should place the switch where it will not be subjected to extreme temperatures,
humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:
The ambient temperature should be between 32 and 104 degrees Fahrenheit (0 to 40 degrees Celsius).
The ambient temperature should be between 32 and 104 degrees Fahrenheit (0 to 40 degrees Celsius).
The relative humidity should be less than 90 percent, non-condensing.
Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards for IEC 801-3,
Level 2 (3V/M) field strength.
Make sure that the switch receives adequate ventilation. Do not block the ventilation holes on each side of the
switch or the fan exhaust port on the rear of the switch.
- The power outlet should be within 1.8 meters of the switch.
Connecting to Power
Step 1: Connect the supplied AC power cord to the receptacle on the back of the switch, and then plug it into a
standard AC outlet with a voltage range from 100 to 240 Vac.
Step 2: Disconnect the power cord if you want to shut down the switch.
Rear view
CUSTOMER
SUPPORT
INFORMATION
Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX
FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web Site: www.blackbox.com y E-mail: info@blackbox.com
Connecting to Your Network
Cable Type & Length
It is necessary to follow the cable specifications below when connecting the switch to your network. Use appropriate cables that meet
your speed and cabling requirements.
Cable Specifications
Speed
Connector
Port Speed
Half/Full Duplex
Cable
Max.
Distance
10BASE-T
RJ-45
10/20 Mbps
2-pair UTP/STP Cat. 3, 4, 5
100 m
100BASE-TX
RJ-45
100/200 Mbps
2-pair UTP/STP Cat. 5
100 m
1000BASE-SX
(*Wavelength of 850nm)
SC
1000/2000 Mbps
62.5/125µm multi-mode fiber
220 m
SC
1000/2000 Mbps
50/125µm multi-mode fiber
550 m
SC
1000/2000 Mbps
62.5/125µm multi-mode fiber
550 m
SC
1000/2000 Mbps
10/125µm single-mode fiber
20 km
1000BASE-LX
(*Wavelength of 1300nm)
Cabling
Step 1: First, ensure the power of the switch and end devices are turned off.
<Note> Always ensure that the power is off before any installation.
Step 2: Prepare cable with corresponding connectors for each type of port in use.
<Note> To connect two regular RJ-45 ports between switches or hubs, you need a cross-over cable.
Step 3: Consult Cable Specifications Table on previous page for cabling requirements based on connectors and
speed.
Step 4: Connect one end of the cable to the switch and the other end to a desired device.
Step 5: Once the connections between two end devices are made successfully, turn on the power and the switch is
operational.
For management configuration, please refer to user’s manual at page 14.
CUSTOMER
SUPPORT
INFORMATION
Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX
FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web Site: www.blackbox.com y E-mail: info@blackbox.com
Download PDF