Automation Direct CDS-USER-M Owner's Manual
Automation Direct CDS-USER-M is a powerful automation device that can help you automate a variety of tasks. With its easy-to-use interface and wide range of features, the CDS-USER-M is perfect for both beginners and experienced users. Whether you're looking to automate a simple task or a complex process, the CDS-USER-M can help you get the job done.
PDF
Document
Advertisement
Advertisement
Manual Number: P2CDS-USER-M ~ WARNING ~ Thank you for purchasing automation equipment from Automationdirect.com®, doing business as, AutomationDirect. We want your new automation equipment to operate safely. Anyone who installs or uses this equipment should read this publication (and any other relevant publications) before installing or operating the equipment. To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and usually change with time. It is your responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation is in compliance with the latest revision of these codes. At a minimum, you should follow all applicable sections of the National Fire Code, National Electrical Code, and the codes of the National Electrical Manufacturer’s Association (NEMA). There may be local regulatory or government offices that can also help determine which codes and standards are necessary for safe installation and operation. Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation. Our products are not fault-tolerant and are not designed, manufactured or intended for use or resale as on-line control equipment in hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life support machines, or weapons systems, in which the failure of the product could lead directly to death, personal injury, or severe physical or environmental damage (“High Risk Activities”). AutomationDirect specifically disclaims any expressed or implied warranty of fitness for High Risk Activities. For additional warranty and safety information, see the Terms and Conditions section of our catalog. If you have any questions concerning the installation or operation of this equipment, or if you need additional information, please call us at 770-844-4200. This publication is based on information that was available at the time it was printed. At AutomationDirect we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without any obligation. This publication may also discuss features that may not be available in certain revisions of the product. Trademarks This publication may contain references to products produced and/or offered by other companies. The product and company names may be trademarked and are the sole property of their respective owners. AutomationDirect disclaims any proprietary interest in the marks and names of others. Copyright© 2024, Automationdirect.com® Incorporated All Rights Reserved No part of this manual shall be copied, reproduced, or transmitted in any way without the prior, written consent of Automationdirect. com® Incorporated. AutomationDirect retains the exclusive rights to all information included in this document. ~ ADVERTENCIA ~ Gracias por comprar equipo de automatización de Automationdirect.com®. Deseamos que su nuevo equipo de automatización opere de manera segura. Cualquier persona que instale o use este equipo debe leer esta publicación (y cualquier otra publicación pertinente) antes de instalar u operar el equipo. Para reducir al mínimo el riesgo debido a problemas de seguridad, debe seguir todos los códigos de seguridad locales o nacionales aplicables que regulan la instalación y operación de su equipo. Estos códigos varian de área en área y usualmente cambian con el tiempo. Es su responsabilidad determinar cuales códigos deben ser seguidos y verificar que el equipo, instalación y operación estén en cumplimiento con la revisión mas reciente de estos códigos. Como mínimo, debe seguir las secciones aplicables del Código Nacional de Incendio, Código Nacional Eléctrico, y los códigos de (NEMA) la Asociación Nacional de Fabricantes Eléctricos de USA. Puede haber oficinas de normas locales o del gobierno que pueden ayudar a determinar cuales códigos y normas son necesarios para una instalación y operación segura. Si no se siguen todos los códigos y normas aplicables, puede resultar en daños al equipo o lesiones serias a personas. No garantizamos los productos descritos en esta publicación para ser adecuados para su aplicación en particular, ni asumimos ninguna responsabilidad por el diseño de su producto, la instalación u operación. Nuestros productos no son tolerantes a fallas y no han sido diseñados, fabricados o intencionados para uso o reventa como equipo de control en línea en ambientes peligrosos que requieren una ejecución sin fallas, tales como operación en instalaciones nucleares, sistemas de navegación aérea, o de comunicación, control de tráfico aéreo, máquinas de soporte de vida o sistemas de armamentos en las cuales la falla del producto puede resultar directamente en muerte, heridas personales, o daños físicos o ambientales severos (“Actividades de Alto Riesgo”). Automationdirect.com específicamente rechaza cualquier garantía ya sea expresada o implicada para actividades de alto riesgo. Para información adicional acerca de garantía e información de seguridad, vea la sección de Términos y Condiciones de nuestro catálogo. Si tiene alguna pregunta sobre instalación u operación de este equipo, o si necesita información adicional, por favor llámenos al número 770-844-4200 en Estados Unidos. Esta publicación está basada en la información disponible al momento de impresión. En Automationdirect.com nos esforzamos constantemente para mejorar nuestros productos y servicios, así que nos reservamos el derecho de hacer cambios al producto y/o a las publicaciones en cualquier momento sin notificación y sin ninguna obligación. Esta publicación también puede discutir características que no estén disponibles en ciertas revisiones del producto. Marcas Registradas Esta publicación puede contener referencias a productos producidos y/u ofrecidos por otras compañías. Los nombres de las compañías y productos pueden tener marcas registradas y son propiedad única de sus respectivos dueños. Automationdirect.com, renuncia cualquier interés propietario en las marcas y nombres de otros. Propiedad Literaria© 2024, Automationdirect.com® Incorporated Todos los derechos reservados No se permite copiar, reproducir, o transmitir de ninguna forma ninguna parte de este manual sin previo consentimiento por escrito de Automationdirect.com® Incorprated. Automationdirect.com retiene los derechos exclusivos a toda la información incluida en este documento. Los usuarios de este equipo pueden copiar este documento solamente para instalar, configurar y mantener el equipo correspondiente. También las instituciones de enseñanza pueden usar este manual para propósitos educativos. ~ AVERTISSEMENT ~ Nous vous remercions d’avoir acheté l’équipement d’automatisation de Automationdirect.com®, en faisant des affaires comme, AutomationDirect. Nous tenons à ce que votre nouvel équipement d’automatisation fonctionne en toute sécurité. Toute personne qui installe ou utilise cet équipement doit lire la présente publication (et toutes les autres publications pertinentes) avant de l’installer ou de l’utiliser. Afin de réduire au minimum le risque d’éventuels problèmes de sécurité, vous devez respecter tous les codes locaux et nationaux applicables régissant l’installation et le fonctionnement de votre équipement. Ces codes diffèrent d’une région à l’autre et, habituellement, évoluent au fil du temps. Il vous incombe de déterminer les codes à respecter et de vous assurer que l’équipement, l’installation et le fonctionnement sont conformes aux exigences de la version la plus récente de ces codes. Vous devez, à tout le moins, respecter toutes les sections applicables du Code national de prévention des incendies, du Code national de l’électricité et des codes de la National Electrical Manufacturer’s Association (NEMA). Des organismes de réglementation ou des services gouvernementaux locaux peuvent également vous aider à déterminer les codes ainsi que les normes à respecter pour assurer une installation et un fonctionnement sûrs. L’omission de respecter la totalité des codes et des normes applicables peut entraîner des dommages à l’équipement ou causer de graves blessures au personnel. Nous ne garantissons pas que les produits décrits dans cette publication conviennent à votre application particulière et nous n’assumons aucune responsabilité à l’égard de la conception, de l’installation ou du fonctionnement de votre produit. Nos produits ne sont pas insensibles aux défaillances et ne sont ni conçus ni fabriqués pour l’utilisation ou la revente en tant qu’équipement de commande en ligne dans des environnements dangereux nécessitant une sécurité absolue, par exemple, l’exploitation d’installations nucléaires, les systèmes de navigation aérienne ou de communication, le contrôle de la circulation aérienne, les équipements de survie ou les systèmes d’armes, pour lesquels la défaillance du produit peut provoquer la mort, des blessures corporelles ou de graves dommages matériels ou environnementaux («activités à risque élevé»). La société AutomationDirect nie toute garantie expresse ou implicite d’aptitude à l’emploi en ce qui a trait aux activités à risque élevé. Pour des renseignements additionnels touchant la garantie et la sécurité, veuillez consulter la section Modalités et conditions de notre documentation. Si vous avez des questions au sujet de l’installation ou du fonctionnement de cet équipement, ou encore si vous avez besoin de renseignements supplémentaires, n’hésitez pas à nous téléphoner au 770-844-4200. Cette publication s’appuie sur l’information qui était disponible au moment de l’impression. À la société AutomationDirect, nous nous efforçons constamment d’améliorer nos produits et services. C’est pourquoi nous nous réservons le droit d’apporter des modifications aux produits ou aux publications en tout temps, sans préavis ni quelque obligation que ce soit. La présente publication peut aussi porter sur des caractéristiques susceptibles de ne pas être offertes dans certaines versions révisées du produit. Marques de commerce La présente publication peut contenir des références à des produits fabriqués ou offerts par d’autres entreprises. Les désignations des produits et des entreprises peuvent être des marques de commerce et appartiennent exclusivement à leurs propriétaires respectifs. AutomationDirect nie tout intérêt dans les autres marques et désignations. Copyright© 2024, Automationdirect.com® Incorporated Tous droits réservés Nulle partie de ce manuel ne doit être copiée, reproduite ou transmise de quelque façon que ce soit sans le consentement préalable écrit de la société Automationdirect.com® Incorporated. AutomationDirect conserve les droits exclusifs à l’égard de tous les renseignements contenus dans le présent document. Publication History ProductivityCodesys User Manual Please include the Manual Number and the Manual Issue, both shown below, when communicating with Technical Support regarding this publication. Manual Number: P2CDS-USER-M Issue Date: 1/24/2024 Issue: Issue Date 1st Edition 1/2024 1st Edition Publication History Description of Changes Original Table of Contents In This Manual Introduction...................................................................................................................................... 1–2 Purpose of this Manual .........................................................................................................................1–2 Intended Use of This Product ..............................................................................................................1–2 Benefits of P2CDS-622 with CODESYS Software..................................................................... 1–3 Conventions Used............................................................................................................................ 1–4 Key Topics for Each Chapter...................................................................................................................1–4 Important Online Resources......................................................................................................... 1–5 P2CDS-622 System.......................................................................................................................... 1–6 Preparation....................................................................................................................................................1–6 1. CODESYS IDE Install............................................................................................................................1–6 2. P2CDS-622 Firmware Install.............................................................................................................1–6 3. System Requirements and Installation........................................................................................1–6 4. Installation...............................................................................................................................................1–7 5. PLC On the Network...........................................................................................................................1–7 IEC 61131-3 Supported Editor Types:................................................................................................1–8 Install Hardware............................................................................................................................... 1–9 Apply Power to CPU.......................................................................................................................1–12 Develop HMI Screens directly in the CODESYS Development Environment..................1–13 Chapter 2 - Specifications..................................................................................... 2–1 P2CDS-622 CPU...............................................................................................................................2–2 P2CDS-622 CPU Features..............................................................................................................2–4 P2CDS-622 CPU Programmable RS232/485 Ports..................................................................2–5 Table of Contents P2CDS-622 CPU Ethernet Ports...................................................................................................2–7 P2CDS-622 CPU Micro USB Type C Programming Port........................................................2–8 P2CDS-622 CPU microSD Slot......................................................................................................2–9 microSD Slot.................................................................................................................................................2–9 P2CDS-622 CPU Battery Installation........................................................................................ 2–10 Battery (Optional) ....................................................................................................................................2–10 I/O Modules Overview..................................................................................................................2–11 Intentionally Blank Page........................................................................................................................2–15 ii CDSYS Hardware User Manual, 1st Edition Getting Started Chapter 1 In This Chapter... Introduction...................................................................................................................................... 1–2 Purpose of this Manual .........................................................................................................................1–2 Intended Use of This Product ..............................................................................................................1–2 Benefits of P2CDS-622 with CODESYS Software..................................................................... 1–3 Conventions Used............................................................................................................................ 1–4 Key Topics for Each Chapter...................................................................................................................1–4 Important Online Resources......................................................................................................... 1–5 P2CDS-622 System.......................................................................................................................... 1–6 Preparation....................................................................................................................................................1–6 1. CODESYS IDE Install............................................................................................................................1–6 2. P2CDS-622 Firmware Install.............................................................................................................1–6 3. System Requirements and Installation........................................................................................1–6 4. Installation...............................................................................................................................................1–7 5. PLC On the Network...........................................................................................................................1–7 IEC 61131-3 Supported Editor Types:................................................................................................1–8 Install Hardware............................................................................................................................... 1–9 Apply Power to CPU.......................................................................................................................1–12 Develop HMI Screens directly in the CODESYS Development Environment..................1–13 Chapter 1: Getting Started Introduction Purpose of this Manual Thank you for purchasing the AutomationDirect ProductivityCODESYS CPU. The user manual provides information that will help you install, set up, troubleshoot, and maintain your ProductivityCODESYS project. The manual includes information that is critical to the safety of the personnel, who will install and use the controller, and to the machinery, processes, and equipment controlled by the P2CDS-622 CPU. The manual also includes important information about power and signal wiring, mounting the CPU and I/O modules, and configuring the system. Intended Use of This Product The P2CDS-622 is a Productivity®2000 format CPU allowing implementation of the IEC-61131-3 programming languages through the use of CODESYS software. The CODESYS system is the basis of a comprehensive suite that covers the entire software side of automation including Industrial Internet of Things (IIoT), communication, Soft PLC, drives, and visualization. It offers users practice-oriented, integrated solutions for the convenient configuration of automation applications and provides practical support for accomplishing daily tasks. Users can develop a human machine interface (HMI) and a PLC application in one IEC 61131-3 development system. The CODESYS Visualization tool has proven itself in thousands of industrial machine and plant applications around the world. Any use other than described in this manual is not permitted, as it may expose the user to possible harm and/or damage to the device or connected equipment. The P2CDS-622 CPU must not be altered or modified. The safety instructions as well as the maximum permissible ambient conditions and operating parameters are given in Chapter 2 “Specifications”. This instruction manual is meant to be read thoroughly while being mindful of safe and proper operation. It contains important information on mounting, operating and handling the P2CDS-622. 1–2 CDSYS Hardware User Manual, 1st Edition Chapter 1: Getting Started Benefits of P2CDS-622 with CODESYS Software Choose your functionality • Visualization and communication with other systems • Fieldbus and I/O connection • Testing, debugging, analysis, version control Choose between extensive Industry 4.0 possibilities • Administration platform for your controllers and projects • Data logging and display • • • • • • • • Remote maintenance and remote access Connection to external systems for Big Data/Machine Learning/AI Static code analysis for early detection of potential programming errors Profiling/test automation tools for facilitated acceptance according to EN13849 PLd Creation of graphical user interfaces Remote access for maintenance, diagnostics, monitoring, and debugging via the associated Industry 4.0 platform Cloud-supported analysis of operating data Connection to public cloud systems via MQTT for predictive maintenance by means of AI algorithm For Building Control Systems (Local and Global) • • • • • • • Expandable panel controls, thanks to being manufacturer independent and widely used open systems Industry standard protocols such as Modbus Engineering software for the creation of logical links and sequences Convenient graphical configuration of aggregates/units for trade-specific application Worldwide available visualizations for monitoring and operation Connection of external APIs and cloud providers through IoT clients for efficient energy management, e.g. at the energy exchange Analysis of incoming measurement data in the cloud and presentation of the results on configurable dashboards CDSYS Hardware User Manual, 1st Edition 1–3 Chapter 1: Getting Started Conventions Used NOTE: When you see the “note pad” icon in the left-hand margin, the paragraph to its immediate right will be a special note. Notes represent information that may make your work quicker or more efficient. The word NOTE in boldface will mark the beginning of the text. WARNING: When you see the “exclamation point” icon in the left-hand margin, the paragraph to its immediate right will be a warning. This information could prevent injury, loss of property, or even death in extreme cases. Any warning in this manual should be regarded as critical information that should be read in its entirety. The word WARNING in boldface will mark the beginning of the text. Key Topics for Each Chapter The beginning of each chapter will list the key topics that can be found in that chapter. 1–4 CDSYS Hardware User Manual, 1st Edition Chapter 1: Getting Started Important Online Resources Download the latest version of the CODESYS Software from the CODESYS website: https://us.store.codesys.com/codesys.html NOTE: USB or Ethernet cable is also required for communications between PC and CPU. Follow steps on site to log-in and download the CODESYS software system. NOTE: CODESYS supports the software from their website. Once you establish a user account you will be able to receive support from CODESYS. Access to ADC Community based help for your ProductivityCODESYS projects is available from our website: P2CDS-622. Here you will find acces to our RTD site. A variety of other useful information about the ProductivityCodesys I/O modules, as well as code for example tasks and more is available. In addition, all supported Productivity2000 series power supplies and I/O modules include a convenient installation insert. CDSYS Hardware User Manual, 1st Edition 1–5 Chapter 1: Getting Started P2CDS-622 System Preparation The installation steps are as follows: 1. Install the CODESYS IDE on your PC. 2. Install the latest P2CDS-622 Firmware image file. 3. Install the P2CDS-622 Device Package (.package) file. 4. Configure the Ethernet ports 5. Install the IIoT Library file (optional) if needed. 1. CODESYS IDE Install • • The first task is to load and install the CODESYS software. This can be found at the following CODESYS Store location: https://us.store.codesys.com/ The remaining steps can be found at this RTD site: . The RTD link https://docs.codesys-p2cds622.com/Getting Started/preparation. html There you will find all the information for getting your P2CDS-622 system up and running. 1–6 CDSYS Hardware User Manual, 1st Edition Chapter 1: Getting Started P2CDS-622 System, cont’d IEC 61131-3 Supported Editor Types: • Functional Block Diagram (FBD) • Sequential Function Charts (SFC) • • Structured Text (ST) Ladder Diagram (LD) CODESYS (and P2CDS-622) also supports Continuous Function Charts (CFC) programming, in addition to the aforementioned IEC61131-3 programming types. NOTE: See Appendix A for an explanation of each Editor Type. For most systems such as EtherNet/IP™, portable CODESYS libraries implement the protocol stack for the fieldbus. Additionally, CODESYS offers libraries for Modbus communication (TCP or serial). Benefits: • Identical usage of the protocol stack for different fieldbus technologies • No external software tool required • • • • • Compiling / linking the stack dynamically to the application For Industrial Ethernet systems: No additional hardware required - a standard Ethernet port on the device for EtherNet/IP or Modbus TCP is sufficient Seamless integration of the configurator into the CODESYS Development System Comprehensive integrated diagnostic functions Integrated Commissioning and Diagnosis Functionality Commissioning of the fieldbus system can be carried out with the Online Config Mode even without an available application. Numerous functions for communication diagnostics are available in the user interface and application, such as event loggers or diagnostic information in the device tree and in the application code. CDSYS Hardware User Manual, 1st Edition 1–7 Chapter 1: Getting Started Install Hardware The Productivity®2000 CPU system components snap together to form a configured CPU in minutes. See Chapter 5, Installation and Wiring, for more detailed hardware installation information. What follows are the basic steps: 1. Install power supply in the base and engage locking tab. Locked 2. Install CPU in the base and engage locking tab. 1–8 CDSYS Hardware User Manual, 1st Edition Chapter 1: Getting Started 3. Install I/O Modules and engage locking tabs. 4. Connect appropriate wiring to the power supply (P2-01AC) and I/O (P2-08TRS module) in this example. The power supply and load are connected through separate AC current sources. CDSYS Hardware User Manual, 1st Edition 1–9 Chapter 1: Getting Started 5. Connect USB cable. Programming connections may be via Ethernet cable or USB. P2CDS-622 CPUs have a USB type C programming port. 1–10 CDSYS Hardware User Manual, 1st Edition Chapter 1: Getting Started Apply Power to CPU Ensure proper wiring and the correct voltage is available before connecting wiring to the power supply. Once this is verified, connect power to the power supply. Once power is applied, the CPU will perform a self-evaluation and verification. P2-01DCAC P2-01DCAC P2-01AC P2-01AC P2-01AC P2-01AC 100-240 VAC 12–24 VDC 12-24VDC AC(L) 24VAC 24VAC AC(L) +V ACL AC(N) -V ACN GND GND LOGIC GND LOGIC GND AC(N) GNDGND P2-01DC LOGIC LOGIC GND GND P2-02DC P2-02DC P2-01DC P2-01DC P2-01DC: 24–48 VDC P2-02DC: 24VDC +V -V GND +V 24-48VDC 30W -V 24VDC 50W +V -V LOGIC GND P2-01DC P2-02DC P2-01DC P2-02DC AC(L) +V AC(N) GND CDSYS -V 1st Edition Hardware User Manual, 1–11 Chapter 1: Getting Started Develop HMI Screens directly in the CODESYS Development Environment CODESYS Development System comes with an integrated visualization editor, allowing HMI development without the need for separate software interface. Design visualization screens with direct access to all application variables thanks to the full integration in the IEC 61131-3 Development System, with no tag list comparison required. Visualization screens can be for machine and plant operation, for testing and commissioning, and can be accessed simultaneously by any system with an internet browser (PCs, tablets, smartphones, etc.). NOTE: The P2CDS-622 is an entry level CODESYS PLC that runs on a single 600MHz core. As such, adding complex Visualizations may affect performance. 1–12 CDSYS Hardware User Manual, 1st Edition Specifications Chapter 2 In This Chapter... P2CDS-622 CPU...............................................................................................................................2–2 P2CDS-622 CPU Features..............................................................................................................2–4 P2CDS-622 CPU Programmable RS232/485 Ports..................................................................2–5 P2CDS-622 CPU Ethernet Ports...................................................................................................2–7 P2CDS-622 CPU USB Type C Programming Port....................................................................2–8 P2CDS-622 CPU microSD Slot......................................................................................................2–9 microSD Slot.................................................................................................................................................2–9 P2CDS-622 CPU Battery Installation........................................................................................ 2–10 Battery (Optional) ....................................................................................................................................2–10 I/O Modules Overview..................................................................................................................2–11 P2CDS-622 Wiring, Installation and Safety............................................................................ 2–14 Chapter 2: Specifications P2CDS-622 CPU The P2CDS-622 CPU is a Productivity2000-series compatible CPU. It is compatible with all Productivity2000 modules, with the exception of P2-RS and P1-RX remote slaves, PS-AMC motion controllers, and the following Modules: P2-HSI, P2-HSO, P2-02HSC, and P2-SCM. C UL US R CPU Specifications User Memory 50MB (Includes program, data and documentation) Memory Type Flash and Battery Backed RAM Retentive Memory 1MB (Retain 800KB / Retain-Persistent 200KB) Scan Time 550us (5K Boolean Logic) Interfaces USB IN: USB 2.0 (single port), Program, Monitor, Debug, Firmware Update ETHERNET: Two independent 10/100Mbps RJ-45 connectors PROTOCOLS: Modbus TCP and RTU Client/ Server, EtherNet/IP Scanner/Adapter, MQTT with TLS, Email, SMTP Client VISUALIZATION: “WebVisu” (Web Server) RS232/485: RJ12 connector RS232/485: 4-position Terminal Block Data Logging microSD card slot Hardware Topologies Four (4) Base Groups: Four (4), seven (7), eleven (11), and fifteen (15) slot bases Supported Modules: All P2 Discrete Input and Output modules, all P2 Analog Input and Output modules, P2-04PWM Unsupported Modules: Remote Slaves (P1-RX, P2-RS) and P2-HSO, P2-HSI, P2-02HSC, and P2-SCM modules. IEC 61131-3 Supported Editor Types Functional Block Diagram (FBD) Structured Text (ST) Sequential Function Charts (SFC) Ladder Diagram (LD) Continuous Function Chart (CFC) Real Time Clock Accuracy ±2s per day typical at 25°C ±10s per day maximum at 60°C IMPORTANT! Hot-Swapping Information Note: This device cannot be Hot Swapped. 2–2 CDSYS Hardware User Manual, 1st Edition Chapter 2: Specifications P2CDS-622 CPU Specifications, cont’d General Specifications P2CDS-622 CPU Operating Temperature 0° to 60°C (32° to 140°F) Storage Temperature -20° to 70°C (-4° to 158°F) Humidity 5 to 95% (non-condensing) Altitude 2,000 meters, max. Pollution Degree 2 Environmental Air No corrosive gases permitted Vibration IEC60068-2-6 (Test Fc) Shock IEC60068-2-27 (Test Ea) Overvoltage Category II Heat Dissipation 4800mW Enclosure Type Open Equipment Module Location Controller slot in the local base in a Productivity2000 System Weight 139g (4.9 oz) Agency Approvals UL 61010-1 and UL 61010-2-201 File E139594, Canada & USA CE (EN 61131-2 EMC, EN 61010-1 and EN 61010-2-201 Safety) CPU Run/Stop Switch RUN position Executes user program, run-time edits possible STOP position Does not execute user program, normal program load position CPU Status Indicators PWR Green LED is illuminated when power is ON RUN Green LED is illuminated when CPU is in RUN mode CPU Red LED is illuminated during power ON reset, power down, or watch-dog time-out CDSYS Hardware User Manual, 1st Edition 2–3 Chapter 2: Specifications P2CDS-622 CPU Features 2–4 CDSYS Hardware User Manual, 1st Edition Chapter 2: Specifications P2CDS-622 CPU Programmable RS232/485 Ports The P2CDS-622 CPU RJ12 style connector and a 4-position terminal may each be programmed for RS232 or RS485 connections. These ports may be used for: • Modbus RTU Master connections • Modbus RTU Slave connections • ASCII full or half duplex communications • Custom Protocol Incoming and Outgoing communications RS232 Specifications TXD RXD RTS GND Maximum Output Load (TXD/RTS) Minimum Output Voltage Swing Output Short Circuit Protection RS232 Transmit output RS232 Receive input Handshaking output for modem control (RJ12 Only) Logic ground 3kΩ, 1000 pf ±5V ±15mA RJ12 Connector Specifications Description Data Rates +5V Cable Power Port Status LED Cable Options CDSYS Programmable RS232/485 Port - Non-isolated RS232 DTE port connects the CPU as a Modbus/ASCII master or slave to a peripheral device. Includes ESD and built in surge protection - Non-isolated RS485 port connects the CPU as a Modbus/ASCII master or slave to a peripheral device. Includes ESD/EFT protection and automatic echo cancellation when transmitter is active Selectable, 1200, 2400, 4800, 9600, 19200, 33600, 38400, 57600, and 115200 210mA maximum at 5V, ±5%. Reverse polarity and overload protected. Green LED illuminated when active for TXD, RXD and RTS EA-MG-PGM-CBL D2-DSCBL USB-RS232 with D2-DSCBL FA-CABKIT Hardware User Manual, 1st Edition 2–5 Chapter 2: Specifications P2CDS-622 CPU Programmable RS485/232 Ports RS485 Specifications TXD+/RXD+ RS485 transceiver high TXD-/RXDGND Input Impedance Electrical Fast Transient Protection Minimum Differential Output Voltage Fail Safe Inputs RS485 transceiver low Logic Ground 19kΩ 120Ω. To use, add jumper between pin 1 and pin 2. Resistor is internally connected between pins 1 and 3. 50 transceivers, 19kΩ each, 60Ω termination ±250mA, thermal shut-down protection Contact ±4KV, Air ±8KV per IEC61000-4-2 (Cable is installed for testing) ±1KV per IEC61000-4-4 1.5 V with 60Ω load Logic high input state if inputs are connected Maximum Common Mode Voltage -7.5 V to 12.5 V Termination Resistance (TB Jumper wire "T" to "+") Maximum Load Output Short Circuit Protection Electrostatic Discharge Protection Terminal Block Specifications Description Programmable RS485/232 Port - Non-isolated RS232 DTE port connects the CPU as a Modbus/ ASCII master or slave to a peripheral device. Includes ESD and built in surge protection - Non-isolated RS485 port connects the CPU as a Modbus/ASCII master or slave to a peripheral device. Includes ESD/EFT protection and automatic echo cancellation when transmitter is active Data Rates Selectable, 1200, 2400, 4800, 9600, 19200, 33600, 38400, 57600, and 115200 Port Status LED Green LED illuminated when active for TXD and RXD Cable Options Go to AutomationDirect.com for RS232 and 485 cable selection. 4 Position Terminal Block 2–6 CDSYS Hardware User Manual, 1st Edition Chapter 2: Specifications P2CDS-622 CPU Ethernet Ports Ethernet Port (RJ45 style connectors on bottom of CPU) used for: • Connection to a PC running the programming software • Modbus TCP Client (64 Servers) connections (Modbus requests sent from the CPU) • Modbus TCP Server (16 Clients) connections (Modbus requests received by the CPU) • EtherNet/IP Scanner (64 Adapters) • EtherNet/IP Adapter (4 scanners) with 8 connections per device. • Outgoing E-mail • MQTT Client (4 brokers) • Rear port does not have Default Gateway or DNS capability. Ethernet Specifications Port Name ETHERNET Description Standard transformer isolated Ethernet port with built-in surge protection for programming, online monitoring, firmware, MQTT, Email (SMTP client), Modbus/TCP client/server connections (fixed IP or DHCP) and Ethernet/IP Scanner/Adapter connections. Transfer Rate RJ45 Yellow LED Off = 10Mbps / On = 100 Mbps Port Status LED RJ45 Green LED Solid when network LINK is established. Flashes when port is active (ACT). P2CDS-622 Bottom View CDSYS Hardware User Manual, 1st Edition 2–7 Chapter 2: Specifications P2CDS-622 CPU USB Type C Programming Port The P2CDS-622 CPU has a standard USB C Slave input for programming and online monitoring, with built-in surge protection. Capable of 480Mbps. USB Type C Specifications Port Name Description USB C Standard USB C Slave input for programming and online monitoring, with built-in surge protection. Transfer Rate 480Mbps Port Status LED Green LED is illuminated when LINK is established to programming software. USB Type A to USB Type C: 6ft cable part # USB-CBL-AC6 Cables P2CDS-622 2–8 CDSYS Hardware User Manual, 1st Edition Chapter 2: Specifications P2CDS-622 CPU microSD Slot microSD Slot The SD Card can be used for the Data Logging in the project or program transfer. When an SD Card is inserted, the “μSD” LED will flash green a few times then stay on steady green. The “Unmount” button is pressed prior to removing the SD card. When pressed, the μSD port LED flashes momentarily during the unmounting and then will be off indicating it is safe to remove the SD Card. Pin Pin 1 SDSD 1 2 3 4 5 6 7 8 DAT2 DAT2 CD/ CD/DAT3 DAT3 CMDCMD VDDVDD CLK CLK VSS VSS DAT0 DAT0 DAT1 DAT1 Hardware User Manual, 1st Edition 2–9 1 8 2 3 4 5 6 7 8 microSD Specifications Port Name microSD Description Standard microSD socket for data logging or program transfer Maximum Card Capacity Transfer Rate (ADATA microSDHC Class 4 memory card) Port Status LED 32GB Mbps Minimum Typical Maximum Read 14.3 14.4 14.6 Write 4.8 4.9 5.1 Green LED is illuminated when card is inserted and detected CDSYS Chapter 2: Specifications P2CDS-622 CPU Battery Installation Battery (Optional) A battery is included with the CPU module but is not installed. The battery may be installed in order to retain the Time and Date along with any tagname values that are set up as retentive. The battery is not needed for program backup. Battery (Optional) D2-BAT-1 Coin type, 3.0 V Lithium battery, 560mA, battery number CR2354 Note: Although not needed for program backup, an uninstalled battery is included with the P2CDS-622. Install this battery if you want the CPU to retain the Time and Date along with any Tagname values that you have configured as retentive. 2–10 CDSYS Hardware User Manual, 1st Edition Chapter 2: Specifications I/O Modules Overview A variety of analog I/O modules from our Productivity2000 line are available for use with the P2CDS-622 CPU. Please refer to Productivity2000 manual Chapter 2 for detailed technical specifications. Productivity®2000 I/O Modules Supported Part Number Number of Points Description Discrete Input Modules Discrete Input Modules Discrete Output Modules P2-08SIM 8 Input Simulator Module P2-08ND3-1 8 Sinking/Sourcing 12–24 VDC P2-16ND3-1 16 Sinking/Sourcing 12–24 VDC P2-32ND3-1 32 Sinking/Sourcing 12–24 VDC P2-08NE3 8 Sinking/Sourcing 24V AC/DC P2-16NE3 16 Sinking/Sourcing AC/DC P2-32NE3 32 Sinking/Sourcing 24V AC/DC P2-08NAS 8 AC Isolated 100–120 VAC P2-16NA 16 AC Isolated 100–240 VAC Discrete Output Modules P2-08TD1S 8 Isolated Sinking P2-08TD2S 8 Isolated Sourcing P2-15TD1 15 Sinking P2-15TD2 15 Sourcing P2-08TD1P 8 Sinking, Protected P2-08TD2P 8 Sourcing, Protected P2-16TD1P 16 Sinking, Protected P2-16TD2P 16 Sourcing, Protected P2-32TD1P 32 Sinking, Protected P2-32TD2P 32 Sourcing, Protected P2-08TAS 8 Isolated AC P2-16TA 16 AC Output P2-08TRS 8 Isolated Relay P2-16TR 16 Relay Output CDSYS Hardware User Manual, 1st Edition 2–11 Chapter 2: Specifications I/O Modules Overview, continued Productivity®2000 I/O Modules Supported Part Number Description Analog Input Modules Analog Input Modules P2-04AD 4 Voltage/Current P2-04AD-1 4 Current P2-04AD-2 4 Voltage P2-08AD-1 8 Current P2-08AD-2 8 Voltage P2-08ADL-1* 8 Current P2-08ADL-2* 8 Voltage P2-16AD-1 16 Current P2-16AD-2 16 Voltage P2-16ADL-1* 16 Current P2-16ADL-2* 16 Voltage P2-06RTD 6 RTD Input P2-08THM 8 Thermocouple Input P2-08NTC 8 Thermistor Input Analog Output Modules 1 18.23 2 14.23 3 4.00 4 4.23 5 13.56 6 16.32 7 8.00 8 7.54 Analog Output Modules 2–12 Number of Points CDSYS P2-04DA 4 Voltage/Current P2-04DA-1 4 Current P2-04DA-2 4 Voltage P2-04DAL-1* 4 Current P2-04DAL-2* 4 Voltage P2-08DA-1 8 Current P2-08DA-2 8 Voltage P2-08DAL-1* 8 Current P2-08DAL-2* 8 Voltage P2-16DA-1 16 Current P2-16DA-2 16 Voltage P2-16DAL-1* 16 Current P2-16DAL-2* 16 Voltage Hardware User Manual, 1st Edition Chapter 2: Specifications I/O Modules Overview, continued 1I00.00 2I04.00 3I00.00 4I04.00 5I00.00 6I04.00 7I00.00 8I SPARE Productivity®2000 I/O Modules Supported Part Number Number of Points Description Analog Combination Modules P2-08AD4DA-1 8/4 Analog Input/Output (Current) P2-8AD4DA-2 8/4 Analog Input/Output (Voltage) Combination Analog I/O Module Specialty Modules Part Number Description P2-04PWM High-speed pulse-width modulation NOTE: Unsupported Modules: Remote Slaves (P2-RS) and Intelligent modules (P2-HSO, P2-HSI, P2-02HSC, and P2-SCM. CDSYS Hardware User Manual, 1st Edition 2–13 Chapter 2: Specifications P2CDS-622 Wiring, Installation and Safety P2CDS-622 is supported by Productivity2000 system hardware and has the same installation and safety guidelines. Please refer to Chapter 5 “Installation and Wiring” in the P2000 user manual for details concerning installation procedures and wiring suggestions. 2–14 CDSYS Hardware User Manual, 1st Edition ">

Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement
Key features
- Easy-to-use interface
- Wide range of features
- Perfect for both beginners and experienced users
- Can help you automate a variety of tasks
- Can help you automate simple and complex processes