10/100Mbps Fast Ethernet Switch FSD-805 / FSD-805SC / FSD-805S15 User's Manual Trademarks Copyright © PLANET Technology Corp. 2008. Contents subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners. Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness for a particular purpose. PLANET has made every effort to ensure that this User’s Manual is accurate; PLANET disclaims liability for any inaccuracies or omissions that may have occurred. Information in this User’s Manual is subject to change without notice and does not represent a commitment on the part of PLANET. PLANET assumes no responsibility for any inaccuracies that may be contained in this User’s Manual. PLANET makes no commitment to update or keep current the information in this User’s Manual, and reserves the right to make improvements to this User’s Manual and/or to the products described in this User’s Manual, at any time without notice. If you find information in this manual that is incorrect, misleading, or incomplete, we would appreciate your comments and suggestions. FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. CE Mark Warning This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. WEEE Warning To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment, end users of electrical and electronic equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately. Revision PLANET 8-Port 10/100Mbps Fast Ethernet Switch User's Manual For Models: FSD-805 / FSD-805SC / FSD-805S15 Revision: 1.0 (May, 2008) Part No: EM_FSD805v1.0 (2350-A31150-000) TABLE OF CONTENTS 1. INTRODUCTION................................................................. 6 1.1 Package Contents........................................................ 6 1.2 How to Use This Manual . ............................................ 6 1.3 Product Features.......................................................... 7 1.4 Product Specifications................................................... 8 2. INSTALLATION................................................................... 9 2.1Product Description...................................................... 9 2.1.1 Product Overview.............................................. 10 2.1.2 Switch Front Panel............................................ 10 2.1.3 LED Indicators.................................................. 11 2.1.4 Switch Rear Panel............................................. 11 2.2Installing the Switch.................................................. 11 2.2.1 Desktop Installation.......................................... 12 3. Switch Operation............................................................. 14 3.1Address Table............................................................ 14 3.2Learning................................................................... 14 3.3Forwarding & Filtering................................................ 14 3.4Store-and-Forward..................................................... 15 3.5Auto-Negotiation........................................................ 15 4. TROUBLESHOOTING......................................................... 17 APPENDIX A: NETWORKING CONNECTION............................. 18 A.1 Switch's RJ-45 Pin Assignments.................................. 18 A.2 RJ-45 cable Pin Assignments...................................... 18 A.3 Fiber Optical Cable Connection Parameter.................... 19 1.INTRODUCTION 1.1 Package Contents Check the contents of your package for following parts: ● Fast Ethernet Switch x 1 ● User's manual x 1 ● Power cord x 1 ● Rubber feet x 4 If any of these are missing or damaged, please contact your dealer immediately, if possible, retain the carton including the original packing material, and use them against to repack the product in case there is a need to return it to us for repair. 1.2 How to Use This Manual This Fast Ethernet Switch User Manual is structured as follows: Chapter 2 Installation The chapter explains the feature, functionality and the physical installation of the Switch. Chapter 3 Switch operation The chapter explains the Fast operation. Ethernet Switch transmit Chapter 4 Troubleshooting The chapter explains the troubleshooting of the Fast Ethernet Switch. Appendix A This chapter contains cable information of the Fast Ethernet Switch. 1.3 Product Features ● Complies with the IEEE 802.3 Ethernet and IEEE 802.3u Fast Ethernet standard ● Features Store-and-Forward mode with wire-speed filtering and forwarding rates ● Support 2K MAC address table ● Support to handle up to 1522 bytes packet size ● LED indicators for simple diagnostics and management ● Hardware based 10/100Mbps auto-negotiation ● Full / Half-Duplex capability on every TX ports, total bandwidth is up to 200Mbps per port ● IEEE 802.3x PAUSE frame flow control for full duplex operation ● Backpressure flow control for half duplex operation ● One shared 100Base-FX interface for up to 2km (multi-mode fiber 50µm/125µm) on FSD-805SC ● One shared 100Base-FX interface for up to 15km (singlemode fiber 9µm/125µm) on FSD-805S15 ● Automatic source address learning and aging ● Internal power adapter 100-240V AC, 50/60Hz, 0.2A ● FCC, CE class A compliant 1.4 Product Specifications Product Hardware Specification 10/100Base-TX Ports 100Base-FX SC Port Dimensions (W x D x H) Weight Power Requirement Power Consumption / Dissipation Switch Specification Switch Processing Scheme Address Table Share data Buffer Flow Control Switch fabric Throughput (packet per second) FSD-805 FSD-805SC FSD-805S15 8 - 8 8 1 1 191 mm x 85 mm x 26 mm 325g Internal power 100-240V AC, 50/60Hz, 0.2A 4.3 watts / 14.6 BTU Store-and-Forward 2K entries 1Mbit on-chip frame buffer Back pressure for half duplex, IEEE 802.3x Pause Frame for full duplex 1.6Gbps 11.9Mpps 10/100Base-TX: 2-Pair UTP Cat. 3, 4, 5 (100meters, max.) EIA/TIA-568 100-ohm STP (100meters, max.) Network cables 100Base-FX: Multi-mode optic fiber 62.5/125μm, 50/125μm (FSD805SC. 2km, max.) Single-mode optic fiber 9/125μm (FSD-805S15. 15km, max.) Standards Conformance Standards Compliance IEEE 802.3 Ethernet IEEE 802.3u Fast Ethernet IEEE 802.3x Full-duplex flow control Temperature Operating: 0~50 degree C Storage: -40~70 degree C Humidity Operating Operating: 5% to 90%, Storage: 5% to 90% (Noncondensing) Regulation Compliance FCC Part 15 Class A, CE 2.INSTALLATION This section describes the functionalities of the Fast Ethernet Switch’s components and guides how to install it on the desktop. Basic knowledge of networking is assumed. Please read this chapter completely before continuing. In the following section, the term “Switch” means the three Switches, i.e. FSD-805, FSD-805SC and FSD-805S15; term of “switch” can be any third part switches. 2.1 Product Description The PLANET FSD-805 / FSD-805SC and FSD-805S15 are 10/100Mbps Fast Ethernet Switches in a compact housing for easily desktop placement. With 8 ports respectively and it’s Auto-negotiation capability, all the RJ-45 ports can be configured to speeds of 10/20Mbps or 100/200Mbps automatically; With increasing bandwidth requirements for local area networks, the Switch provide non-blocking wire-speed performance and 1.6Gbps internal switching fabric, it is the ideal option to alleviate bottlenecks in client/ server and peer-to-peer environments in a cost-effective way. The FSD-805SC and FDS-805S15 provide one shared 100BaseFX port with port 1, TP / Fiber port Selection through the DIP switch. All RJ-45 copper interfaces support 10/100Mbps Auto-Negotiation for optimal speed detection through RJ-45 Category 6, 5 or 5e cables. Support is standard for Auto-MDI/MDI-X that can detect the type of connection to any Ethernet device without requiring special straight or crossover cables. The Flow Control function allows your Fast Ethernet Switch supported routers and servers to directly connect to this Switch for fast, reliable data transfer. 2.1.1 Product Overview PLANET FSD-805 / FSD-805SC and FSD-805S15 are 10/100Mbps Fast Ethernet Switch, with 8 RJ-45 10/100Mbps ports for cost effective high-performance network connectivity. With its 1.6Gbps non-blocking switch fabric, the Switch can also provide a local, high bandwidth. The Switch also supports Store-andForward forwarding scheme to ensure low latency and high data integrity, eliminates unnecessary traffic and relieves congestion on critical network paths. With an intelligent address recognition algorithm, the Switch could recognize up to 2K different MAC address and enables filtering and forwarding at full wire speed. Choice of multi-mode / single mode 100Base-FX SC interface on FSD-805SC and FSD-805S15, the fiber transmit distance can be 2km and 15km 2.1.2 Switch Front Panel Figure 2-1 & 2-2 & 2-3 shows a front panel of FSD-805 / FSD805SC and FSD-805S15 Figure 2-1 FSD-805 front panel Figure 2-2 FSD-805SC front panel Figure 2-3 FSD-805S15 front panel 10 2.1.3 LED Indicators FSD-805 / FSD-805SC / FSD-805S15 LED PWR Color Green LNK/ACT Green Function Lit: indicate the Switch has power. Lit: indicate the link through that port is successfully established. Blink: indicate that the Switch is actively sending or receiving data over that port. 2.1.4 Switch Rear Panel Figure 2-4 shows a rear panel of FSD-805 / FSD-805SC and FSD-805S15. Figure 2-4 FSD-805 / FSD-805SC / FSD-805S15 rear panel Power Notice 1. The device is a power-required device, it means, it will not work till it is powered. If your networks should active all the time, please consider using UPS (Uninterrupted Power Supply) for your device. It will prevent you from network data loss or network downtime. 2. In some area, installing a surge suppression device may also help to protect your Switch from being damaged by unregulated surge or current to the Switch or the power adapter. 11 2.2 Installing the Switch This part describes how to install your Fast Ethernet Switch and make connections to it. Please read the following topics and perform the procedures in the order being presented. This Switch does not need software configuration. Note 2.2.1 Desktop Installation To install the Switch on desktop, simply follow the next steps: Step 1: Attach the rubber feet to the recessed areas on the bottom of the Switch. Step 2: Place the Switch on desktop near an AC power source. Step 3: Keep enough ventilation space between the Switch and the surrounding objects. Note When choosing a location, please keep in mind the environmental restrictions discussed in Chapter 1, Section 1.4 Product Specifications. Step 4: Connect your Switch to network devices. A. Connect one end of a standard network cable to the 10/100 RJ-45 ports on the Back of the Switch. B. Connect the other end of the cable to the network devices such as printer servers, workstations or routers…etc. 12 Note Connection to the Switch requires UTP Category 5 network cabling with RJ-45 tips. For more information, please see the Cabling Specification in Appendix A. Step 5: Supply power to the Switch. A. Connect one end of the power cable to the Switch. B. Connect the power plug of the power cable to a standard wall outlet. When the Switch receives power, the Power LED should remain solid Green. Note When need use the 100Base-FX port of FSD805SC and FSD-805S15, please changed the DIP Switch on the left side. The DIP Switch control the Port 1 runs at TP or Fiber operation mode. Fiber or TP port choose 13 3. Switch Operation 3.1 Address Table The Switch is implemented with an address table. This address table composed of many entries. Each entry is used to store the address information of some node in network, including MAC address, port no, etc. This information comes from the learning process of Ethernet Switch. 3.2 Learning When one packet comes in from any port. The Switch will record the source address, port no. And the other related information in address table. This information will be used to decide either forwarding or filtering for future packets. 3.3 Forwarding & Filtering When one packet comes from some port of the Ethernet Switching, it will also check the destination address besides the source address learning. The Ethernet Switching will lookup the address-table for the destination address. If not found, this packet will be forwarded to all the other ports except the port which this packet comes in. And these ports will transmit this packet to the network it connected. If found, and the destination address is located at different port from this packet comes in, the Ethernet Switching will forward this packet to the port where this destination address is located according to the information from address table. But, if the destination address is located at the same port with this packet comes in, then this packet will be filtered. There by increasing the network throughput and availability. 14 3.4 Store-and-Forward Store-and-Forward is one type of packet-forwarding techniques. A Store-and Forward Ethernet Switching stores the incoming frame in an internal buffer, do the complete error checking before transmission. Therefore, no error packets occurrence, it is the best choice when a network needs efficiency and stability. The Ethernet Switch scans the destination address from the packet-header, searches the routing table provided for the incoming port and forwards the packet, only if required. The fast forwarding makes the Switch attractive for connecting servers directly to the network, thereby increasing throughput and availability. However, the Switch is most commonly used to segment existing hubs, which nearly always improves overall performance. An Ethernet Switching can be easily configured in any Ethernet network environment to significantly boost bandwidth using conventional cabling and adapters. Due to the learning function of the Ethernet Switching, the source address and corresponding port number of each incoming and outgoing packet are stored in a routing table. This information is subsequently used to filter packets whose destination address is on the same segment as the source address. This confines network traffic to its respective domain, reducing the overall load on the network. The Switch performs “Store and Forward" therefore, no error packets occur. More reliably, it reduces the re-transmission rate. No packet loss will occur. 3.5 Auto-Negotiation The STP ports on the Switch have built-in “Auto-negotiation”. This technology automatically sets the best possible bandwidth when a connection is established with another network device 15 (usually at Power On or Reset). This is done by detect the modes and speeds at the second of both device is connected and capable of, both 10Base-T and 100Base-TX devices can connect with the port in either Half- or Full-Duplex mode. For non auto-negotiation devices, the Switch will only run in Halfduplex mode. 16 4. TROUBLESHOOTING This chapter contains information to help you solve issues. If the Switch is not functioning properly, make sure the Fast Ethernet Switch was set up according to instructions in this manual. The per port LED is not lit Solution: Check the cable connection of the Switch. 100Base-TX port link LED is lit, but the traffic is irregular Solution: Check that the attached device is not set to dedicate full duplex. Some devices use a physical or software switch to change duplex modes. Auto-negotiation may not recognize this type of full-duplex setting. Why the Switch doesn’t connect to the network Solution: Check the LNK/ACT LED on the Switch Try another port on the Switch Make sure the cable is installed properly Make sure the cable is the right type Turn off the power. After a while, turn on power again. 17 APPENDIX A: NETWORKING CONNECTION A.1 Switch‘s RJ-45 Pin Assignments ¢ 10/100Mbps, 10/100Base-TX RJ-45 Connector pin assignment Contact MDI Media Dependant Interface MDI-X Media Dependant Interface -Cross 1 Tx + (transmit) Rx + (receive) 2 Tx - (transmit) Rx - (receive) 3 Rx + (receive) Tx + (transmit) 4, 5 6 7, 8 Not used Rx - (receive) Tx - (transmit) Not used Implicit implementation of the crossover function within a twisted-pair cable, or at a wiring panel, while not expressly forbidden, is beyond the scope of this standard. A.2 RJ-45 cable Pin Assignments The standard RJ-45 receptacle/connector 18 There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight cable and crossover cable connection: Straight Cable 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 SIDE 1 SIDE 2 SIDE 1 SIDE 2 1 = White/Orange 2 = Orange 3 = White/Green 4 = Blue 5 = White/Blue 6 = Green 7 = White/Brown 8 = Brown 1 = White/Orange 2 = Orange 3 = White/Green 4 = Blue 5 = White/Blue 6 = Green 7 = White/Brown 8 = Brown SIDE 1 SIDE 2 1 = White/Orange 2 = Orange 3 = White/Green 4 = Blue 5 = White/Blue 6 = Green 7 = White/Brown 8 = Brown 1 = White/Orange 2 = Green 3 = White/Orange 4 = Blue 5 = White/Blue 6 = Orange 7 = White/Brown 8 = Brown Straight Cable 1 2 3 4 5 6 7 8 SIDE 1 1 2 3 4 5 6 7 8 Figure A-1 Straight-Through and Crossover Cable Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network A.3 Fiber Optical Cable Connection Parameter The wiring details are as below: ¢ Fiber Optical patch Cables: Standard Fiber Type Cable Specification 100Base-FX (1300nm) Multi-mode 50/125μm or 62.5/125μm 100Base-FX (1310nm) Single-mode 9/125μm 19 EC Declaration of Conformity For the following equipment: *Type of Product: *Model Number: 8-Port 10/100Mbps Desktop Fast Ethernet Switch (Internal Power) FSD-805 / FSD-805SC / FSD-805S15 * Produced by: Manufacturer‘s Name : Manufacturer‘s Address: Planet Technology Corp. 11F, No 96, Min Chuan Road Hsin Tien, Taipei, Taiwan , R. O.C. is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive on (89/336/EEC,92/31/EEC,93/68/EEC). For the evaluation regarding the EMC, the following standards were applied: Conducted / Radiated Harmonic Flicker Immunity ESD RS EFT/ Burst Surge CS Magnetic Field Voltage Disp EN 55022 EN 61000-3-2 EN 61000-3-3 EN 55024 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11 (1998+A1:2000+A2:2003) (2000) (1995+A1:2001) (1998+A1:2001+A2:2003) (1995+A1: 1998+A2:2000) (2002+A1: 2000) (1995+A1: 2000+A2: 2001) (1995+A1: 2000) (1996+A1: 2000) (1993+A1: 2000) (1994+A1: 2000) Responsible for marking this declaration if the: _ Manufacturer Authorized representative established within the EU Authorized representative established within the EU (if applicable): Company Name: Planet Technology Corp. Company Address: 11F, No.96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C Person responsible for making this declaration Name, Surname Kent Kang Position / Title : Product Manager Taiwan Place 7, May., 2008 Date Legal Signature PLANET TECHNOLOGY CORPORATION e-mail: [email protected] http://www.planet.com.tw 11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. Tel:886-2-2219-9518 Fax:886-2-2219-9528
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement