Bryant | TSTATBBNAC01-C | pds zonekit.0.4 - County Heating & Air Conditioning Inc

ZONEBB3Z(AC/HP)01
THREE ZONE CONTROL
Product Data
THREE ZONE CONTROL
The Bryant 3--Zone system is comprised of a 3--zone controller
and a duct temperature sensor. Thermostats and dampers are not
included in the kit. A variety of non--programmable and
programmable thermostats are available to satisfy the home
owner’s personalized comfort needs. The 3--zone system does not
require a field supplied transformer.
FEATURES / BENEFITS
The Bryant 3--Zone system allows the air conditioning and heating
equipment to control temperatures in 3 distinct spaces or zones
within a building. Each zone has independent temperature settings
controlled by a conventional thermostat. Each zone can have up to
5 dampers.
DUCT TEMPERATURE OPTIMIZER — Offers maximum
equipment protection to help ensure long life.
PROGRAMMABLE/NON--PROGRAMMABLE
THERMOSTAT COMPATIBILITY — Matches the right
thermostat to the homeowner’s comfort and lifestyle.
DIAGNOSTIC LEDs — Intelligent system diagnostics to let
homeowners know if there is a problem with their system.
EMERGENCY HEAT SWITCH — Allows manual override for
emergency heat strip operation when utilizing a heat pump.
MAXIMUM CYCLE RATE — Allows 4 equipment cycles per hr
(cph) providing maximum equipment protection.
SELECTION JUMPERS — Designed for easy configuration.
ADDITIONAL OPTIONS
S
S
S
S
S
S
S
S
S
S
S
S
TimeGuard override
Compressor protection
Modulating damper control in emergency situations
Damper fuse protection
High-- and low--temperature limits
Auto changeover from any zone
RH and RC for voltage isolation
Bypass setup routine
Staging time for eneergy savings
Automatic checkout with installer mode
Overrride zoning switch
Timer override for serviceability
PRODUCT DATA INFORMATION
Physical Characteristics
Applications
Dimensions: 10.75’’ x 7.75’’ x 1.75’’
Up to 2 stages cool/2 stages heat
Wiring Requirements
Appearance:
Control Module Cover: Plastic, white color
Wire Terminal Cover: Metal, white color
Power supply: Dedicated 24vac, 40va, 60 hz isolated
transformer, field supplied.
Electrical Characteristics
Wiring material: Standard thermostat wire 18 to 24 gage.
Input Volts/Amps: 24vac, Less than 40va
Environmental Requirements
Operating Temperature/Relative Humidity:
Equipment Controller and wireless receiver: 32_F to 150_F,
95% rh non--condensing
ZONEBB3Z(AC/HP) -- 01
THERMOSTATS
PART NUMBERS
PROGRAM
GAS
TSTATBBPRH01 ---B
TSTATBBPHH01 ---B
TSTATBBPAC01 ---B
TSTATBBPHP01 ---B
TSTATBBP2S01 ---B
TSTATBBPF701
TSTATBBPF101
TSTATBBREC01
TSTATBBPRF01
7---Day or NP
7---Day
7---Day
7---Day
7---Day
7---Day
1---Day
*
*
*
*
*
*
*
7---Day
*
TSTATBBNAC01 ---C
TSTATBBNHP01 ---C
TSTATBBN2S01 ---C
TSTATBBPQ501
NP
NP
NP
5---2 Day
*
*
*
*
TSTATBBSAC01
TSTATBBSHP01
TSTATBBBAC01 ---B
TSTATBBBHP01 ---B
TSTATBBPB501
TSTATBBPB101
TSTATBBP2W01
TSTATBBN2W01
TSTATBBNB001
TSTATBBNQ001
5---2 Day
5---2 Day
NP
NP
5---2 Day
1--- Day
7---Day
NP
NP
NP
*
*
ELECTRIC
Preferred
*
*
*
*
*
*
*
*
Legacy
*
*
*
*
Legacy RNC
*
*
*
*
*
*
*
*
*
*
*
HEAT
PUMP
HYBRID
HEATt
*
*
*
*
HEAT
COOL
*
*
*
*
3
3
1
2
3
2
2
2
2
1
1
2
2
2
*
2
2
*
*
1
2
3
1
1
1
2
1
1
2
1
2
2
2
1
1
1
1
2
2
1
1
1
1
*
*
*
*
Heat Or Cool Only ( 2 wires)
Heat Or Cool Only (2 wires)
*
THERMOSTAT ACCESSORIES
PART NUMBER
TSTATXXSEN01 ---B*
TSTATXXNBP01 ---C†
TSTATXXPBP01†
TSTATXXBBP01†
TSTATXXSBP01†
TSTATXXCNV10‡
DESCRIPTION
Outdoor Air Temperature Sensor
Backplate for Deluxe Non ---Programmable ---C Thermostat
Backplate for Programmable Thermostat and Thermidistat Control
Backplate for Legacy RNC Model Thermostat
Backplate for Preferred Programmable Thermostat
Thermostat Conversion Kit (4 to 5 Wire) — 10 Pack
* Outdoor--temperature sensor is an accessory for all Bryant electronic thermostats, except the non--programmable air conditioner version
and Legacy RNC model thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor
air temperature sensor must be used with the Hybrid Heat thermostat.
† Plate is designed to cover surrounding wall area located behind thermostat.
‡ Thermostat--conversion kit is a 24vac accessory that can turn a 4--wire thermostat application into a 5--wire application. The kit can also be
used to replace a broken thermostat wire, or add an extra wire when needed. Do not use this kit with the AC model of the Legacy RNC or
Preferred Programmable thermostat.
2
ACCESSORIES
DESCRIPTION
Round Dampers
Rectangular Dampers
Rectangular Barometric Bypass
Round Barometric Bypass
Slip---In Dampers
DAMPERS
SIZES
6 in.
8 in.
10 in.
12 in.
14 in.
16 in.
8 in. X 10 in.
8 in. X 14 in.
8 in. X 18 in.
8 in. X 24 in.
10 in. X 10 in.
10 in. X 14 in.
10 in. X 18 in.
10 in. X 24 in.
8 in. X 14 in.
8 in. X 24 in.
8 in.
10 in.
12 in.
14 in.
16 in.
Side mount, 8 X 8
Bottom mount, 8 X 8
Side mount, 8 X 10
Bottom mount, 8 X 10
Side mount, 8 X 12
Bottom mount, 8 X 12
Side mount, 8 X 14
Bottom mount, 8 X 14
Side mount, 8 X 16
Bottom mount, 8 X 16
Side mount, 8 X 18
Bottom mount, 8 X 18
Side mount, 8 X 20
Bottom mount, 8 X 20
Side mount, 8 X 22
Bottom mount, 8 X 22
Side mount, 8 X 24
Bottom mount, 8 X 24
Side mount, 10 X 10
Bottom mount, 10 X 10
Side mount, 10 X 12
Bottom mount, 10 X 12
Side mount, 10 X 14
Bottom mount, 10 X 14
Side mount, 10 X 16
Bottom mount, 10 X 16
Side mount, 10 X 18
Bottom mount, 10 X18
Side mount, 10 X 20
Bottom mount, 10 X 20
Side mount, 10 X 22
Bottom mount, 10 X 22
Side mount, 10 X 24
Designates new sizes
3
PART NUMBER
DAMPRND06INC --- B
DAMPRND08INC --- B
DAMPRND10INC --- B
DAMPRND12INC --- B
DAMPRND14INC --- B
DAMPRND16INC --- B
DAMPREC08X10--- B
DAMPREC08X14--- B
DAMPREC08X18--- B
DAMPREC08X24--- B
DAMPREC10X10--- B
DAMPREC10X14--- B
DAMPREC10X18--- B
DAMPREC10X24--- B
DAMPBAR08X14
DAMPBAR08X24
DAMPBAR08INC
DAMPBAR10INC
DAMPBAR12INC
DAMPBAR14INC
DAMPBAR16INC
DAMPSLS08X08--- B
DAMPSLB08X08--- B
DAMPSLS08X10--- B
DAMPSLB08X10--- B
DAMPSLS08X12--- B
DAMPSLB08X12--- B
DAMPSLS08X14--- B
DAMPSLB08X14--- B
DAMPSLS08X16--- B
DAMPSLB08X16--- B
DAMPSLS08x18--- B
DAMPSLB08X18--- B
DAMPSLS08X20--- B
DAMPSLB08X20--- B
DAMPSLS08X22--- B
DAMPSLB08X22--- B
DAMPSLS08X24--- B
DAMPSLB08X24--- B
DAMPSLS10X10--- B
DAMPSLB10X10--- B
DAMPSLS10X12--- B
DAMPSLB10X12--- B
DAMPSLS10X14--- B
DAMPSLB10X14--- B
DAMPSLS10X16--- B
DAMPSLB10X16--- B
DAMPSLS10X18--- B
DAMPSLB10X18--- B
DAMPSLS10X20--- B
DAMPSLB10X20--- B
DAMPSLS10X22--- B
DAMPSLB10X22--- B
DAMPSLS10X24--- B
ZONEBB3Z(AC/HP) -- 01
3---ZONE CONTROL ACCESSORIES
PART NUMBER
DESCRIPTION
ZONEXXODTS01
Duct Temperature Sensor*
* Duct temperature sensor required for heat pump zone board.
DAMPERS (Continued)
SIZES
Bottom mount, 10 X 24
Side mount, 12 X 12
Bottom mount, 12 X 12
Side mount, 12 X 14
Bottom mount, 12 X 14
Side mount, 12 X 16
Bottom mount, 12 X 16
Side mount, 12 X 18
Bottom mount, 12 X 18
Side mount, 12 X 20
Bottom mount, 12 X 20
Side mount, 14 X 14
Bottom mount, 14 X 14
Side mount, 14 X 16
Bottom mount, 14 X 16
Side mount, 14 X 20
Bottom mount, 14 X 20
Side mount, 16 X 16
Bottom mount, 16 X 16
Bottom mount, 16 X 20
DESCRIPTION
ZONEBB3Z(AC/HP) -- 01
Slip---In Dampers (continued)
PART NO.
DAMPSLB10X24--- B
DAMPSLS12X12--- B
DAMPSLB12X12--- B
DAMPSLS12X14--- B
DAMPSLB12X14--- B
DAMPSLS12X16--- B
DAMPSLB12X16--- B
DAMPSLS12X18--- B
DAMPSLB12X18--- B
DAMPSLS12X20--- B
DAMPSLB12X20--- B
DAMPSLS14X14--- B
DAMPSLB14X14--- B
DAMPSLS14X16--- B
DAMPSLB14X16--- B
DAMPSLS14X20--- B
DAMPSLB14X20--- B
DAMPSLS16X16--- B
DAMPSLB16X16--- B
DAMPSLB16X20--- B
Designates new sizes
NOTE: The above dampers are recommended because they use the latest style actuators designed for zoning systems. These actuators are
direct--drive and use slightly less power to operate. If using older style dampers with this zoning system (ie., dampers with a crankarm), it is
recommended to upgrade the actuator to DAMPACT45DEG or DAMPACT90DEG.
DAMPER REPLACEMENT ACCESSORIES
Actuators
Description
45° Actuator for round dampers
90° Actuator for rectangular dampers
Damper Actuator Cover
EBryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231
Part No.
DAMPACT45DEG--- R
DAMPACT90DEG--- R
DAMPACTXXCOV
Printed in U.S.A.
Edition Date: 02/06
Catalog No. PDS ZONEKIT.0.4
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
4
Replaces: NEW