Super Manual Fiber Amplifier
E3X-NA
Adjuster type standard that is the culmination of true ease and simplicity
Features
Self-explanatory LED bar displays of light levels
The previous manual type used the stability and incident level indicators to display the light level change, which was difficult to understand at a glance. The E3X-NA uses the LED bars to display the light level, ensuring the light level change at a glance.
Same "Wire-saving" Connector as
E3X-DA-N
OMRON's original wiring-saving connector, which was inherited from the digital fiber amplifier E3X-DA-N, allows connection of up to 16 units.
Gang-mount up
to 16 Amplifiers
Operation indicator
Approx. 20% or lower
Approx. 10% or lower
Unstable level
Approx. -10% or higher
Approx. -20% or higher
* The vertical movement of the LED light level and operation display shows the light level at a glance.
E3X-NA Conventional model
Master connector
Optical
commu-
nications
Power supply pin
Slave connector
E3X-NA
A-441
Reduced wiring and space requirements for power lines
Example for 5 Amplifiers E3X-NA Series
E3X-NA series
Example for 5 Amplifiers
No relay connectors required.
7 lines
Power supplied from master amplifier through master connector to slave amplifiers.
Less space required.
Reduced Wiring and Space Requirements for Power Lines
Features
Optical Communications to Prevent Mutual
Interference
Optical communication between amplifiers prevents mutual interference. Up to 5 fiber heads can be installed closely, except E3X-NA#F.
Optical commu nications
Up to 5
Amplifiers
Five previous amplifiers
15 lines
Power and output lines required for each amplifier.
Relay connectors
Same Sensing Distance as Previous Longdistance Models
200 mm Reflective Models
Dimensions and Designs Inherited from the
E3X-DA-N Digital Fiber Amplifier
Standard:
E3X-A
Long-distance:
E3X-H
E3X-NA
100mm
Standard model
200mm
50mm 100mm
Note: The above characteristics are ensured with the E32-D11L Reflective Sensor
(long-distance model).
150mm
* The E3X-NA Series does not
have a long-distance model.
200mm Sensing distance
Approximately Seven Times the Detection
Accuracy
Applied Fiber: E32-T16P (screen fiber) set at 100 mm. E3X-
A1 1 (previous model) Minimum detection object: 2.0 mm dia.
E3X-NA 0.3 mm dia.
Digital Fiber Amplifier
E3X-DA-N
Standard-feature
OFF delay timer
Non-removable hinged co
Super manual Amplifier
E3X-NA
10mm
8-turn adjustment knob for precise adjustment (with indicator)
Same 10-mm width as the E3X-DA-N Digital
Fiber Amplifier
(Previously 12 mm)
Easy-to-see indicator
Same shape as the E3X-DA-N Digital Fiber Amplifier
Applied Fiber: E32-T16 (screen fiber) set at 100 mm.
E3X-A11 (previous model) E3X-NA
7 times
Minimum detection object:
2.0 mm dia.
0.3 mm dia.
Addition of high-speed type and waterproof type to the series
A-442 Advanced Photoelectric Sensors
Ordering Information
Amplifier Units
Pre-wired
Item
Standard models
High-speed detection
Mark-detecting models
Water-resistant models
Shape Control output
ON/OFF output
NPN output
E3X-NA11
E3X-NA11F
E3X-NAG11
E3X-NA11V
Model
PNP output
E3X-NA41
E3X-NA41F
E3X-NAG41
E3X-NA41V
Connector type
Item
Standard models
Shape
Applicable Connector
(order separately)
Master E3X-CN11
Slave E3X-CN12
Control output
ON/OFF output
XS3F-M421-40#-A
XS3F-M422-40#-A
NPN output
E3X-NA6
E3X-NA14V
Model
PNP output
E3X-NA8
E3X-NA44V
Water-resistant models
(M8 Connector)
Amplifier Units Connectors (Order Separately) Note: Stickers for Connectors are included as accessories.
Item Shape Cable length No. of conductors Model
Master connector 3 E3X-CN11
2 m
Slave connector 1 E3X-CN12
Precautions for ordering the connector type
Amplifier Units
Refer to the following tables when placing an order. BasicalType ly, Amplifier Units and connectors are sold separately. Standard
NPN
E3X-NA6
PNP
E3X-NA8
Please place an order after referring to the combination giv-
When Using 5 Amplifier Units
Amplifier Units (5 Units)
Sensor I/O Connectors (Order separately)
Size Cable type Shape
Straight
M8 Standard cable
L-shaped
Note: Refer to page NB-6 for details.
Accessories (Order Separately)
Mounting Brackets
Shape Applicable type
E3X-NA#
E3X-NA#F
E3X-NAG#
Model
E39-L143
E3X-NA#V E39-L148
Quantity
1
End Plate
Shape
+
Applicable Connector (order separately)
Master connector Slave connector
E3X-CN11 (3 wires) E3X-CN12 (1 wire)
+
1 Master Connector + 4 Slave Connectors
2 m
Cable length
5 m
4 conductors
2 m
5 m
Model
XS3F-M421-402-A
XS3F-M421-405-A
XS3F-M422-402-A
XS3F-M422-405-A
Model
PFP-M
Quantity
1
E3X-NA
A-443
Rating/performance
Amplifier Units
Type Standard models
Pre-wired
High-speed detection models
Mark-detecting models
Water-resistant models
Connector type
Standard models
Water-resistant models (M8 Connector)
Item
Model
NPN output
PNP output
Light source (wave length)
Power supply voltage
E3X-NA11
E3X-NA41
Red LED (680 nm)
E3X-NA11F
E3X-NA41F
E3X-NAG11
E3X-NAG41
Green LED
(520 nm)
12 to 24 VDC ±10%, ripple (p-p): 10% max.
E3X-NA11V
E3X-NA41V
Red LED (680 nm)
E3X-NA6
E3X-NA8
E3X-NA14V
E3X-NA44V
Current consumption 35 mA max.
Control output
Response time
35 mA max. (at power supply voltage 24 VDC)
35 mA max.
Load current 50 mA (residual voltage 1 V max. each) Open collector output type (depends on the NPN/PNP output format) Light-ON/Dark-ON switch selectable
Operation or reset: 200 s max. *
Operating: 20 s max. Reset: 30 s max.
200 s max. for operation and reset respectively (See note.)
Sensitivity adjustment
8-turn endless adjuster (with indicator)
Protective circuits
Reverse polarity protection, output short-circuit protection, mutual interference prevention (optically synchronized)
Reverse polarity protection, output short-circuit protection
Reverse polarity protection, output short-circuit protection, mutual interference prevention (optically synchronized)
Timer function OFF-delay timer: 40 ms (fixed)
Ambient illuminance Incandescent lamp: 10,000 lux max. Sunlight: 20,000 lux max.
Ambient temperature
Operating: Groups of 1 to 3 Amplifiers: -25 to +55°C, Groups of 4 to 11 Amplifiers: -25 to +50°C, Groups of 12 to
16 Amplifiers: -25 to +45°C Storage: -30 to +70°C (with no icing and condensation)
Ambient humidity Operating/Storage: 35% to 85% RH (with no condensation)
Insulation resistance 20 M min. at 500 VDC
Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute
500 VAC at
50/60 Hz for
1 minute
Vibration resistance 10 to 55 Hz with a 1.5 mm double amplitude for 2 hrs each in X, Y and Z directions
Shock resistance Destruction: 500 m/s
2
for 3 times each in X, Y, and Z directions
Protective structure IEC 60529 IP50 (with Protective Cover attached)
IEC 60529 IP66
(with Protective
Cover attached)
IEC 60529 IP50
(with Protective
Cover attached)
IEC 60529 IP66
(with Protective
Cover attached)
Connector type M8 connector Connection method Pre-wired models (standard length: 2 m)
Weight (Packed state)
Approx. 100 g
Case PBT (polybutylene terephthalate)
Material
Cover Polycarbonate
Approx. 110 g
Polyethersulfone (PES)
Approx. 55 g
Polycarbonate
65 g
Polyethersulfone (PES)
Accessories Instruction manual
* If 8 or more Units are installed side-by-side, the response time will be 350 s max.
A-444 Advanced Photoelectric Sensors
Amplifier Unit Connectors
Item
Rated current
Model
2.5 A
Rated voltage
Contact resistance
E3X-CN11 E3X-CN12
50 V
20 m max. (20 mVDC max., 100 mA max.) [By connection with amplifier unit and connection with adjacent connector (except conductor resistance of cable)]
No. of insertions 50 times (By connection with amplifier unit and connection with adjacent connector)
Material
Housing
Contacts
Weight (Packed state)
PBT (polybutylene terephthalate)
Phosphor bronze/gold-plated nickel
Approx. 55 g Approx. 25 g
Characteristic data (typical)
Number of Turns of Sensitivity Adjuster vs. Sensing Distance
E32-T11L E32-D11L
0.6
0.4
0.2
1.2
1.0
0.8
E3X-NA# (V)
0 2 4
E3X-NA# F
6 8 10
Number of turns
Sensing Distance vs. Hysteresis
E32-T11L
400
300
200
100
0
E32-D11L
2
E3X-NA# (V)
4 6
E3X-NA# F
8 10
Number of turns
100
80
60
40
20
E3X-NA# (V)
0
100 200 300 400 500 600 700
Distance (mm)
10
5
20
15
0
50
E3X-NA# (V)
100 150 200
Distance (mm)
E3X-NA
A-445
Output Circuit Diagram
NPN output
Model
E3X-NA11
E3X-NA6
E3X-NAG11
E3X-NA11F
E3X-NA11V
E3X-NA14V
Operating status of output transistor
Light ON
Timing chart
Mode selection switch
Incident
Interrupted
Operation
ON indicator
(orange)
OFF
Output transistor
ON
OFF
Operate
Load
(Relay)
Reset
T
(Between brown and black)
L ON
(LIGHT ON)
Dark ON
Incident
Interrupted
Operation indicator
(orange)
ON
OFF
Output transistor
ON
OFF
Load
(Relay)
T
Operate
Reset
(Between brown and black)
D ON
(DARK ON)
Operation indicator
(orange)
Main circuit
Output circuit
1
Brown
Load
4
Black
Control output
3
Blue
12 to 24 VDC
M8 Connector Pin Arrangement
1
2 4
3
Note: Pin 2 is open.
PNP output
Model
E3X-NA41
E3X-NA8
E3X-NAG41
E3X-NA41F
E3X-NA41V
E3X-NA44V
Operating status of output transistor
Light ON
Timing chart
Mode selection switch
Incident
Interrupted
Operation
ON indicator
(orange)
OFF
Output transistor
ON
OFF
Load
(Relay)
T
Operate
Reset
(Between brown and black)
L ON
(LIGHT ON)
Dark ON
Incident
Interrupted
Operation indicator
(orange)
ON
OFF
Output transistor
ON
OFF
Load
(Relay)
T
Operate
Reset
(Between brown and black)
D ON
(DARK ON)
Operation indicator
(orange)
Main circuit
Output circuit
1
Brown
4
Black
Control output
Load
3
Blue
M8 Connector Pin Arrangement
1
2 4
3
12 to 24 VDC
Note: Pin 2 is open.
Connectors (Sensor I/O connectors)
Termination No.
3
4
2
1
3
4
1
2
XS3F-M421-402-A
XS3F-M421-405-A
XS3F-M422-402-A
XS3F-M422-405-A
Color of cable conductors
Brown
White
Blue
Black
Class
For DC
Wire, outer jacket color
Brown
White
Blue
Black
Note: Pin 2 is not used.
Connector pin No.
A
B
C
D
Application
Power supply (+V)
-
Power supply (0 V)
Output
A-446 Advanced Photoelectric Sensors
Nomenclature:
Amplifier Units
Sensitivity Indicator
8-turn sensitivity adjuster
Lock Button Incident level indicators
Operation indicator
Operation Mode Selector
Use to switch between Light ON and Dark ON modes.
Timer switch
ON: Timer function is ON.
OFF: Timer function is OFF.
Operation
Indicator status
In addition to the operation indicator (orange), E3X-NA has indicators that denotes the incident level (4 green and 1 red indicators). Use them for optical axis adjustment and maintenance.
Indicator status (L/ON)
Operation indicator (L/ON)
Incident level
Operation indicator Incident level indicators
Not lit Lit (See note)
Not lit
Approx. 80% to 90% of operating level
Not lit
Approx. 80% to 90% of operating level
Precautions
Correct Use
Amplifier Units
Design
Communications Hole
The window provided in the side face of the unit is a communication window for prevention of mutual interference when it is connected with the other unit. Note that the optional Mobile
Console E3X-MC11 cannot be used. When the incident level of the sensor is excessive, mutual interference prevention may not be activated. At that time, make adjustment with the sensitivity adjuster. When the unit is used with the E3X-DA-N series, mutual interference prevention is not activated.
Mounting
Connection/removing of amplifier units
(Connection)
1. Install the Amplifier Units one at a time onto the DIN track.
2. Slide the Amplifier Units together, line up the clips, and press the Amplifier Units together until they click into place.
Not lit or lit
Approx. 90% to 110% of operating level
Lit
Approx. 110% to 120% of operating level
Lit
Approx. 120% min. of operating level
Note: The rightmost indicator is turned ON at the "0 incident level".
Clip
Clip into place
(Removing)
Slide one unit away from the other and remove them one by one. (Do not remove the connected units together from the
DIN rail.)
Note: 1 . When the amplifier units are interconnected, the operating ambient temperature changes depending on the number of connected amplifier units. Check "Ratings/Performance".
2 . Before connecting or removing the units, always switch power off.
Operating Environment
Ambient Conditions
Always remove dust, dirt, etc. from the optical communication window, which may disable communication.
Miscellaneous
Protective Cover
Be sure to set the Protective Cover before use.
E3X-NA
A-447
Amplifier Unit Connectors
Installation
Installation Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit until it clicks into place.
Mounting End Plate (PFP-M)
Depending on the installation type, an Amplifier Unit may move during operation. In this case, use an End Plate.
Before installing an End Plate, remove the clip from the master Amplifier Unit using a nipper or similar tool.
Insert
2. Join Amplifier Units together as required after all the Master and Slave Connectors have been inserted.
3. Apply the supplied seal to the non-connection surface of the master/slave connector.
The sensor bottom is also equipped with the clip removing mechanism.
1. Insert the clip to be removed into the slit underneath the clip on another Amplifier Unit.
Sticker
Note: Apply the seal to the grooved side.
Sticker
Removing Connectors
1. Slide the slave Amplifier Unit for which the Connector is to be removed away from the rest of the group.
2. After the Amplifier Unit has been separated, press down on the lever on the Connector and remove it. (Do not attempt to remove Connectors without separating them from other
Amplifier Units first.)
Press down
Lever
2. Remove the clip by rotating the Amplifier Unit.
Rotate
Remove
Pull Strengths for Connectors (Including Cables)
E3X-CN11: 30 N max. E3X-CN12: 12 N max.
A-448 Advanced Photoelectric Sensors
Dimensions (Unit: mm)
Amplifier Units
Pre-wired
E3X-NA11
E3X-NA11F
E3X-NA41
E3X-NA41F
E3X-NAG11
E3X-NAG41
Two, 2.4 dia.
10
8
10.7
With Mounting Blanket Attached
Incident level indicators
Operation indicator
( A ) * 1
4-dia., 3-conductor, vinyl-insulated round cable
(conductor cross-sectional
area: 0.45 m‡u; insulation
diameter: 1.1 mm)
3
13.05
15.75
9.2
38.6
64.3
5.3
31.5
9.9
4.1
22.4
13
Two, 3.2 dia. holes
3.4
22.4
10.75
16
34.8
Holes for optical communications * 2
2.4
4
Mounting bracket (E39-L143); Sold separately
Stainless steel (SUS304)
4.4
Mounting Holes
2-M3
16
16
Note: * 1. The mounting bracket can also be used on side A.
* 2. The hole for optical communications is for
preventing mutual interference. There is no
hole for E3X-NA#F models.
Amplifier Units with cables,
Water-resistant Models
E3X-NA11V
E3X-NA41V
With Mounting Blanket Attached
28.65
25.95
9.2
* 2
Operation indicator
Incident level indicators
81.5
6.9
40
( A ) * 1
Two, 2.4 dia.
12
8
10.7
33
9.9
3.9
3.4
4.3
Mounting Holes
2-M3
11.5
23.9
14.4
23.9
16
2.8
11.2
16
37
67.2
16
3.4
Holes for optical communications
5.4
6.6
Mounting bracket (E39-L148); Sold separately
Stainless steel (SUS304)
5.4
3.4
N o t e : * 1 . T h e m o u n t i n g b r a c k e t c a n a l s o b e u s e d o n s i d e A .
* 2 .
4-dia., 3-conductor, vinyl-insulated round cable
(conductor cross-sectional area: 0.45 mm²;
insulation diameter: 1.1 mm)
E3X-NA
A-449
Connector type
E3X-NA6
E3X-NA8
Incident level indicators
Operation indicator
10 3
Two, 2.4 dia.
13.05
15.75
9.2
64.3
8
10.7
Dimensions with Master Connector Connected
71
67.5
64.3
1.8
9.9
3.4
1.7
4.2
13
5.1
3.9
1.8
38.6
36.7
6.2
1.7
14
31.5
5.5
Holes for optical communications
(for preventing mutual interference)
Dimensions with Slave Connector Connected
71
67.5
64.3
E3X-CN11:
4.0 dia.
31.5
1.5
31.5
1.5
12.95
1.8 5.1 3.9
Amplifier Units M8 Connectors,
Water-resistant Models
E3X-NA14V
E3X-NA44V
N o t e : * 1 . T h e m o u n t i n g b r a c k e t c a n a l s o b e u s e d o n s i d e A .
10
4
1.8 5.1 3.9
With Mounting Blanket Attached
28.65
25.95
9.2
Two, 2.4 dia.
12
Operation indicator
Incident level indicators
81.5
6.9
40
( A ) * 1
3
4.8
E3X-CN12: 2.6 dia.
12.95
17.45
11.55
10
4
2.8
M8
8
10.7
33
9.9
Mounting Holes
2-M3
3.9
3.4
4.3
11.5
23.9
14.4
23.9
16
11.2
16
37
67.2
16
3.4
Holes for optical communications
11
5.4
Mounting bracket (E39-L148); Sold separately
Stainless steel (SUS304)
5.4
3.4
A-450 Advanced Photoelectric Sensors
Amplifier Unit Connectors
Master connector
E3X-CN11
2.9
10
6
2.6
10.7
6.8
4
2,000
+50
0
4-dia., 3-conductor, vinyl-insulated round cable (conductor cross-sectional area: 0.45 mm ²; insulation diameter: 1.1 mm)
4 dia.
14.4
6
0.8
8.4
15.1
Slave connector
E3X-CN12
2.9
10
6
2.6
14.4
6
3
0.8
10.7
6.8
4
2,000
+50
0
4-dia., 3-conductor,vinyl-insulated round cable (conductor cross-sectional area: 0.45 mm ²; insulation diameter: 1.1 mm)
2.6 dia.
8.4
15.1
Accessories (Order Separately)
Mounting Brackets
H-5
30
± 2
50
+5
0
10
± 2
30
± 2
50
+5
0
10
± 2
E3X-NA
A-451
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No.
E23E-EN-01
In the interest of product improvement, specifications are subject to change without notice.
A-452 Advanced Photoelectric Sensors