993B-0306 PPH1SD Series Maytag tsl.indd - eNora

TECHNICAL SPECIFICATIONS
Model PPH1SD Series
TM
M1010 Product Line
Single Packaged Heat Pump
13 SEER - 3, 4 and 5 Ton Units
•
•
•
10 YEAR
WARRANTY
WORRY-FREE
PERFORMANCE
5 YEAR
DEPENDABILITY
PROMISE
The PPH1SD Series single packaged heat pumps are high efficiency
self contained cooling and heating units that can be installed on a
roof or on a slab. The convertible unit design makes installations
simple in all applications. Units are ETL and ETLc listed.
Features and Benefits
• Compact Footprint/Low Profile
Easy to handle and transport.
• Five Minute Restart Time Delay
When the unit shuts down, a five minute delay keeps the unit from
restarting, eliminating the highest cause for compressor failure.
• Heavy-Gauge, Full Perimeter Base Rails
Facilitates forklift handling and curb mounting.
• Convertible Air Delivery
Horizontal or downflow to accommodate rooftop or horizontal
application.
• Galvanized Steel Cabinet
Unit is trimmed in a silicone-protected polyester finish with a 950 hour
salt spray finish that resists corrosion 50% better than comparable units.
• Plastic Coated Coil Guard and Mesh Hail Guard
Will never rust and protects the coil from being damaged by balls,
lawnmowers, hail etc.
• Externally Accessible Service Ports
Quick access to refrigerant system without disrupting operation.
• Access to Controls and Major Components
Easy in and out service.
• Corrosion-Resistant Drain Pan
Quickly drains away evaporator condensate.
• Service Access Panels
Allows easy access to all major components and the compressor.
Designed to make servicing easier for the Contractor.
• Easy to Install
Electric heat strip provides up to 20 KW of heat output.
• Proven, Industry Standard Components
Easier service and availability.
• Quiet Operation and Low Vibration
20" fan blade combined with custom venturi condenser fan.
• Accessories
Roof curbs and more.
• Time / Temperature Defrost
A reliable, industry standard control offers various time settings to meet
any type climate.
• Low Pressure Control
Loss of charge protection ensures long compressor life.
• 10 Year Residential Parts and Labor Warranty
and 5 Year Dependability Promise
The best warranty in the business.
2
IDENTIFICATION CODE
P
P
H
1
S
D
024
K
Electrical Code
K = 208/230-60-1
P = Premier
P = Packaged
Nominal Capacity
x 1000 Btu
H = Heat Pump
Series
Square Duct
Connections
D = 13 SEER
SPECIFICATIONS
Model
Number
Performance
Capacity - Heating BTUH
Efficiency - HSPF
Capacity - Cooling BTUH
Efficiency - SEER
EER (Btuh/watt)
Electric Rating - 60Hz (a)
Phase
Operating Voltage Range
Min. Circuit Ampacity (a)
Field Wire Size - AWG (a)
Total Unit - Amps
Compressor Data
Volts
Rated Load Amps
Lock Rotor Amps
Indoor Blower
Type
Motor HP-RPM Range
Motor - Amps
Outdoor Fan
Motor - HP / RPM
Motor - Amps
Fan Diameter / CFM
Refrigerant Charge - Oz.
Net Weight lbs.
Shipping weight lbs.
036
PPH1SD
048
060
33,500
7.7
34,800
13.00
11.0
45,000
7.7
46,000
13.00
11.0
51,000
7.7
55,500
13.00
11.0
1
187-253
27.7
10
23.2
1
187-253
36.7
8
30.8
1
187-253
42.5
6
35.5
208-230
17.9
88
208-230
23.6
137
208-230
28.0
169
Fixed Torque
1/2-1100
4.1
Fixed Torque
3/4-1400
6.0
Fixed Torque
3/4-1600
6.0
1/4 - 1100
1.2
20 / 3800
127
460
470
1/4 - 1100
1.2
20 / 3800
293
570
580
1/3 - 1000
1.5
20 / 4000
224
580
590
BLOWER PERFORMANCE
Model Number
PPH1SD
036
048
060
**
*
*
**
**
*
Speed
Tap T1
Tap T2
Tap T3
Tap T4
Tap T5
Tap T1
Tap T2
Tap T3
Tap T4
Tap T5
Tap T1
Tap T2
Tap T3
Tap T4
Tap T5
0.1
1150
1230
1400
1600
1700
1515
1580
1740
1960
2090
1515
1580
1740
1960
2090
0.2
1050
1190
1350
1500
1650
1450
1520
1690
1910
2050
1450
1520
1690
1910
2050
External Static Pressure Drop-inches water column
0.3
0.4
1000
950
1120
1080
1200
1150
1400
1300
1600
1565
1380
1350
1460
1400
1650
1600
1840
1820
2010
1975
1380
1350
1460
1400
1650
1600
1840
1820
2010
1975
0.5
850
1000
1080
1200
1530
1300
1360
1540
1780
1940
1300
1360
1540
1780
1940
0.6
780
950
1030
1050
1480
1250
1300
1500
1740
1900
1250
1300
1500
1740
1900
* Denotes factory set cooling and heat pump speed
** Denotes factory set electric heating speed
3
DIMENSIONS
24.9
3/4" NPT Female
Drain Connector
DOWNFLOW
SUPPLY DUCT
OPENING
47.5
CG
13.5
16.0
16.0
13.5
B
13.3
12.0
12.0
23.5
DOWNFLOW
RETURN DUCT
OPENING
A
Top View
Center of Gravity
4
Height (in inches)
C
Model
Number
PPH1SD
Unit
Weight
A
B
with base
rails
without base
rails
036
460
28.0
25.5
35.0
35.3
048
570
29.5
26.0
43.0
39.3
060
580
29.5
26.0
43.0
39.3
DIMENSIONS continued
1.8
1.75 Ø Power Entry (Capped)
1.25 Ø Power Entry
0.88 Ø Control Wiring Entry
30
27.2
23.6
4.00
Side View
4.0
5.0
SUPPLY
C
CONDENSING
COIL
RETURN
13.5
16.0
8
13.5
16.0
14.7
13.45
11.75
22.75
55.8
Back (Duct) View
5
6
4
3
102.9
127.9
36.7
61.7
15
20
0
5
4
0
00
4
3
111.7
136.7
42.5
67.5
15
20
0
5
0
00
117.5
142.5
15
20
2
82.1
92.5
8
10
6
2
76.3
86.7
8
10
8
00
1
3
67.5
77.9
8
10
6
52.9
5
10
27.9
0
0
1
3
4
4
8
0
2
3
4
6
8
1
2
4
4
6
10
1
2
4
4
6
8
1
2
4
4
6
8
2
3
4
6
8
10
150
125
110
100
90
70
150
125
100
90
80
60
150
110
80
70
60
45
-
36.5
36.5
36.5
36.5
36.5
-
30.7
30.7
30.7
30.7
30.7
-
23.6
23.6
23.6
23.6
23.6
-
8
8
8
8
8
-
8
8
8
8
8
-
10
10
10
10
10
-
8
8
8
8
8
-
8
8
8
8
8
-
10
10
10
10
10
-
8
8
8
8
8
-
8
8
8
8
8
-
10
10
10
10
10
-
60
60
60
60
60
-
50
50
50
50
50
-
40
40
40
40
40
-
56.8
56.8
56.8
46.4
31.8
-
56.8
56.8
56.8
45.6
31.2
-
54.3
54.3
54.3
43.7
29.3
917167
917166
X
X(2)
X(2)
PPH1SD-036K
PPH1SD-048K
PPH1SD-060K
3- Pkgd. Units
Heater
H
Heater Kit
3
IDENTIFICATION CODE
HK
X(2)
X(2)
X(2)
917168
008
- H
X(3)
X(3)
X(2)
917169
H3HK-015H-01
Electric
Heater KW
H3HK-010H-01
NA = Not Applicable.
( ) = Number of internal circuit breaker kits required.
X(2)
X(2)
X
H3HK-008H-01
H3HK-005H-01
Model
Number
HEATER APPLICATION MATRIX
Circuit B (Blower & Heater)
Multiple Supply Circuit Option
-
4
4
4
6
8
-
4
4
4
6
8
-
6
6
6
6
10
1
-
6
6
6
8
8
-
6
6
6
8
8
-
6
6
6
8
10
-
6
6
8
8
8
-
6
6
6
8
8
-
8
8
8
8
10
Stages
X(1)
X(1)
NA
917173
H3HK-020H-21
No. of Breakers
X(1)
X(1)
X
917172
H3HK-015H-21
Electric Code
H=240-1-60
0
X(3)
X(3)
NA
917170
H3HK-020H-01
*When overcurrent rating exceeds 60, internal circuit breakers must be installed in addition to branch circuit protection at distribution panel.
PPH1SD-X60K
PPH1SD-X48K
PPH1SD-X36K
Model
Number
Circuit A (Compressor & Fan)
Circuit C (Heater Only)
60
60
60
50
35
-
60
60
60
50
35
-
60
60
60
45
30
-
50
25
-
-
-
-
50
25
-
-
-
-
50
25
-
-
-
-
6
10
-
-
-
-
6
10
-
-
-
-
6
10
-
-
-
-
8
10
-
-
-
-
8
10
-
-
-
-
8
10
-
-
-
-
8
10
-
-
-
-
8
10
-
-
-
-
8
10
-
-
-
-
60
30
-
-
-
-
60
30
-
-
-
-
60
30
-
-
-
-
Maximum
Maximum
Maximum
Maximum
OverMinimum Rec Wire Rec Wire Rec Wire
OverOverMinimum Rec Wire Rec Wire Rec Wire
Heater
Minimum Rec Wire Rec Wire Rec Wire
OverMinimum Rec Wire Rec Wire Rec Wire
Circuit Gauge (60° Gauge (75° Gauge (90° current
Circuit Gauge (60° Gauge (75° Gauge (90° current
Circuit Gauge (60° Gauge (75° Gauge (90° current
Circuit Gauge (60° Gauge (75° Gauge (90° current
Installed
Amp.
C Cu)
C Cu)
C Cu)
Rating*
C Cu)
Rating*
Amp.
C Cu)
C Cu)
C Cu)
Rating*
Amp.
C Cu)
C Cu)
C Cu)
Rating*
Amp.
C Cu)
C Cu)
Nom. KW
Single Supply Circuit Option
ELECTRICAL DATA
ACCESSORIES
Description
Roof Curb (8”)
Roof Curb (14”)
Roof Curb (18”)
Roof Curb (24”)
Filter Rack, All Downflow Applications (not required with economizer)
Filter Kit (not required with economizer) for Horizontal Applications
PPH1SC 036
Filter Kit (not required with economizer) for Horizontal Applications
PPH1SC 048K - 060K
Universal Hard Start Kit
High Pressure Switch Kit
Low Ambient Kit
P-Trap Kit
Outdoor Thermostat Kit
Part Number
547830
547831
547850
547851
547885
547888
547889
912933
913550
913549A
913810
913852
7
CERTIFICATION APPLIES
ONLY WHEN THE
COMPLETE SYSTEM
IS LISTED WITH ARI
Before purchasing this appliance, read important energy cost and efficiency
information available from your retailer. Specifications and illustrations subject
to change without notice and without incurring obligations.
Maytag is a registered trademark of the Maytag Corporation and is used under license.
993B-0306 (Replaces 993B-1105)
Printed in U.S.A. (03/06)