Gaumard Super Chloe S222.100 is a patient simulator designed for healthcare training. It features a realistic anatomy, including a simulated airway, circulatory system, and organs, allowing for immersive practice of various medical procedures. This advanced model incorporates features such as site-specific heart and lung sounds, a left blood pressure arm with a palpable pulse, and a right intravenous access arm. Super Chloe S222.100 also offers a gynecological training package with a realistic vagina and cervix, facilitating exercises like bi-manual pelvic examinations, vaginal examinations, and pap smears.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Gaumard Super Chloe S222.100 User Manual | Manualzz
S222 & S222.250 & S222.100
CLINICAL CHLOE
USER GUIDE
Clinical Chole Patient Simulator is an interactive educational system developed to
assist a certified instructor. It is not a substitute for a comprehensive understanding of
the subject matter and not intended for clinical decision making.
User Guide 22.04.02
©Gaumard Scientific Company, 2022
All Rights Reserved
www.gaumard.com
S222 & S222.250 & S222.100 | USER GUIDE
TABLE OF CONTENTS
1. INTRODUCTION
1.1 SPECIFICATIONS
1.2 TERMINOLOGY
1.3 CARE AND MAINTENANCE
5
5
5
5
2. FEATURES
8
3. INITIAL SETUP
10
3.1 CARE AND CAUTIONS DURING UNBOXING
3.2 PACKAGE CONTENTS
3.3 LOWER BODY ASSEMBLY
3.4 LEG ASSEMBLY
3.5 POWERING ON OMNI
3.6 POWERING ON OMNI 2 (S222.250)
4. WORKING WITH CHLOE
4.1 SYSTEMIC
4.2 AIRWAY
4.3 CIRCULATION
4.4 INTRAVENOUS (IV) ARM (S222.100)
4.5 REPLACING THE IV ARM SKIN (S222.100)
4.6 BREAST EXAMINATION
4.7 GASTROINTESTINAL
4.8 CATHETERIZATION
4.9 ENEMA
4.10 ULCERS
4.11 GYNECOLOGIC EXAMINATION
4.12 AMPUTATION STUMP
5. OPTIONS
5.1 HEART AND LUNG SOUNDS FEATURE (S222.100)
5.2 BLOOD PRESSURE LEFT ARM (S222.100)
10
10
11
13
14
15
17
17
19
26
28
35
37
41
42
46
46
47
47
49
49
52
Table of Contents | iii
S222 & S222.250 & S222.100 | User Guide
5.3 BLOOD PRESSURE LEFT ARM (S222.250)
5.4 GERIATRIC FACE SKIN
6. WORKING WITH THE OMNI® CONTROLLER
6.1 OMNI® CONTROLLER FEATURES
6.2 NAVIGATION SUBMENU
7. WORKING WITH THE OMNI®2 TABLET
7.1 OMNI®2 TABLET FEATURES
7.2 BATTERY USAGE
7.3 TURNING OFF THE SIMULATOR
8. ROUTINE MAINTENANCE
8.1 FLUSHING THE FLUID RESERVOIRS
9. TROUBLESHOOTING
57
61
63
63
64
67
67
69
70
71
71
75
9.1 OMNI® IS NOT TURNING ON
75
9.2 CONNECTIVITY TO THE SIMULATOR CANNOT BE ESTABLISHED
OR IS LOST
75
9.3 OMNI® OR OMNI®2 IS NOT DETECTING ANY COMPRESSIONS OR
VENTILATIONS
76
9.4 OMNI®2 TAKES TOO LONG TO BOOT UP
76
9.5 CPR IS NOT DETECTED IN OMNI®2
76
10. APPENDIX
10.1 CONSUMABLE PARTS LIST
10.2 SUPER CHLOE AND CLINICAL CHLOE FEATURES
10.3 GAUMARD SALES TERMS AND CONDITIONS 10.4 END USER LICENSE AGREEMENT
10.5 EXCLUSIVE ONE-YEAR LIMITED WARRANTY
10.6 CONTACT TECHNICAL SUPPORT
10.7 GENERAL INFORMATION
Table of Contents | iv
77
77
77
79
81
84
85
85
S222 & S222.250 & S222.100 | USER GUIDE
1. INTRODUCTION
1.1 SPECIFICATIONS
• 40 lbs (18.1 kg)
• 5'5 in (165 cm)
1.2 TERMINOLOGY
Facilitator: The person conducting the simulation; an instructor or lab staff member
Provider A person participating in the simulation as a healthcare provider
1.3 CARE AND MAINTENANCE
The lubricant and other accessories provided are for use with the accompanying patient
simulator only. The lubricant and other accessories are not suitable for human use or
medical treatment/diagnosis and should never be used for such purposes.
CAUTION: Damage caused by misuse may void the manufacturer’s warranty. Failure to
comply with the following guidelines could result in damage to the equipment.
General
• Do not wrap this or any other Gaumard product in newsprint.
• Marks made with ballpoint pens, ink or marker cannot be removed.
• Replacement parts are available from Gaumard or from your distributor.
• Only use simulated blood provided by Gaumard. Other simulated blood containing
sugars and other additive may cause blockage of the fluid system.
Operating Conditions
• Operating the simulator outside these ranges may affect performance:
• Operating temperature: 50°- 95° F (10°- 35° C).
• Humidity: 5%-95% (non-condensing).
Introduction | 5
S222 & S222.250 & S222.100 | USER GUIDE
Cautions
• Treat the simulator with the same precautions used with a real patient.
• Do not attempt to intubate without lubricating the airway adjunct with mineral oil lubricant. Failure to
lubricate the device will make intubation very difficult and is likely to result in damage to the simulator.
• Mouth to mouth resuscitation without a barrier device is not recommended as it may contaminate the airway.
• Do not use povidone iodine on the simulator.
CAUTION: The tubing simulating veins is made of latex which may cause allergic
reactions. Users allergic or sensitive to latex should avoid direct contact with
the tubing. Seek medical attention if an allergic reaction occurs.
Storage
• Store the simulator in a cool, dry place. Extended storage should be between 32 - 85° F (0 -
29° C). Storage above 85° F (29°C) will cause the simulator to soften and slowly warp.
• Humidity: 40%-60% (non-condensing)
• Do not stack or store heavy materials on top of the box.
• Please store and ship in the bag and box provided.
Procedures
• Do not attempt to intubate without lubricating the airway adjunct with mineral oil lubricant. Failure to
lubricate the device will make intubation very difficult and is likely to result in damage to the simulator.
• When simulating drug administration via endotracheal tube, providers must use an empty
syringe. Passing liquids into the trachea or esophagus may cause internal damage.
• Mouth to mouth resuscitation without a barrier device is not recommended, as it will contaminate the airway.
• Treat the simulator with the same precautions that would be used with a real patient.
Cleaning
• Remove all traces of lubricant at the end of each simulation session.
• Remove the fluid using the fill kit provided.
• Drain all the fluid from the dispensing bag and IV Arm by unclamping the drainage
tube and pumping the squeeze bulb attached to the dispensing bag.
• Flush the fluid reservoirs and venous system with a 30:70 mix of isopropyl alcohol to water after each
day of simulation then suction all fluid out. You may also fill the dispensing bag with this mixture.
• The simulator is “splash-proof” but not water proof. Do not submerge in water.
• The simulator should be cleaned with a cloth dampened with diluted
liquid dishwashing soap. Do not clean with harsh abrasives.
• Dry thoroughly after every cleaning.
6 | Introduction
S222 & S222.250 & S222.100 | USER GUIDE
Stoma Care
• Do not clean with alcohol or aggressive solvents.
• Clean the stomas using a mild solution of soap and water.
• Apply baby powder to return the surface to a skin-like feel and appearance. Reapply as needed.
• Always remove the stomas when preparing for transport.
• Do not pack any sharp objects with the stomas.
• Do not press the stomas against soiled surfaces, ink, or newsprint. The stoma material is absorbent.
IV Arm
• Only use Gaumard’s simulated blood provided in the standard package. Any other simulated blood
containing sugar or any additive may cause blockage and/or interruption of the veins in the IV arm.
• The use of needles larger than 22 to 23 gauge will reduce the lifetime of the arm skin and veins.
• Always purge with clean water, then drain the vein reservoirs at the end of each simulation
session. Doing so will retard the formation of mold and prevent clogging of the system.
• The skin of the training arm can be cleaned with a mild detergent, or soap and water. After drying the
arm, lightly dust it with talcum powder. This will keep the training arm supple and easy to use.
• We recommend flushing veins with a 70:30 mix of clean water to isopropyl
alcohol (IPA) after each use to prolong the life of the vasculature.
• For more information regarding the replacement of veins and other consumable items
please contact technical support. Contact information is provided in section 8.3.
WARNING: Vein tubing contains latex which may cause allergic reactions. Users allergic or sensitive to latex
should avoid contact. Stop using the product and seek medical attention if an allergic reaction occurs.
Introduction | 7
S222 & S222.250 & S222.100 | USER GUIDE
2. FEATURES
General
• Medium skin tone is the standard simulator color; light or dark is available at no extra cost
• Realistic hair for haircare exercises and surgical draping
• Realistic eyes for ophthalmic exercises
• Eyes open in an upright position and close in a supine position (One pupil is dilated)
• Removable upper and lower dentures for oral hygiene
• Simulated ear canal for irrigation exercises
• Interchangeable male and female breast inserts
• Strong, realistic joints that facilitate lifelike movements. The simulator
has articulated head, jaw, knees, and ankles.
Airway
• Anatomically accurate airway
• Realistic tongue, epiglottis, vocal chords and esophagus.
• Trachea, bronchi, and lungs enable assessment of airway management skills
• Oral and nasal intubation
• Nasogastric and oral gastric feeding
• Tracheostomy placement and care
• Use an ET tube, LMA, or BVM
CPR
• Practice CPR
• Practice BVM exercises with realistic chest rise
• Ventialtions and chest compressions are logged with the included OMNI Code Blue Pack
Circulation
• Bilateral manual carotid and right radial palpable pulses
• Subcutaneous injection sites located on the deltoids, quadriceps, and upper buttocks.
• Interchangeable male and female organs (included)
• Realistic urethral passage and bladder for catheterization exercises
Other
• Transverse colostomy, ileostomy, and suprapubic stomas to practice irrigation
• Opening for gastronomy
• Enema administration capability
• Vaginal douching and pap smear exercises with realistic vagina and cervix
8 | Features
S222 & S222.250 & S222.100 | USER GUIDE
S222.100 Feature Specific
• Site specific Heart and Lung Sounds with Virtual Stethoscope
• Left Blood Pressure Arm with programmable, palpable radial pulse
• Right Intravenous Access Arm
• Breast palpation capability with 7 abnormal breasts
• Ulcerated foot
GYN TRAINING
• Bi-manual pelvic examination
• Palpation of normal and pregnant uteri
• Vagninal examination including insertion of speculum
• Visual recognition of normal and abnormal cervices
• Uterine sounding
S222 Options
• Ulcerated foot
• Left Blood Pressure Arm with programmable, palpable radial pulse
• Right Intravenous Access Arm
• Site Specific Heart and Lung Sounds with Virtual Stethoscope
S222 & S222.100 Options
• OMNI 2 Link
• Beside Virtual Monitor
• Geriatric Face Skin Accessory
Features | 9
S222 & S222.250 & S222.100 | USER GUIDE
3. INITIAL SETUP
3.1 CARE AND CAUTIONS DURING UNBOXING
• The simulator is shipped partially assembled. Avoid lifting the simulator
by the arms as this may cause damage to the joints.
• Remove the simulator from the box with at least two people. Hold and lift
it out of the protective case from both sides of the torso.
• Rest the simulator on a bed or clean, flat surface capable of supporting the weight of a real adult patient.
NOTE: Remove the legs when transporting the simulator inside the protective case.
3.2 PACKAGE CONTENTS
1.
Upper Body Assembly
11. Detachable Male Genitalia
2. Lower Body Assembly
12. Trachea Tape Roll
3. Right and Left Leg Assembly
13. Pulse Squeeze Bulb Kit
4. Neck Brace
14. Gynecologic Package (S222.100)
5. Decubitus Ulcer
15. Modified BP Cuff (S222.100)
6. Ulcerated Left Foot (S222.100)
16. Power Supply
7. Heart and Lung Sounds Kit (S222.100)
17. AC Adapter for Speakers (S222.100)
8. Rubber stoppers
18. Breast Palpation Kit (S222.100)
9. Urethra adapter
19. Mineral Oil
10. Stomas
20. OMNI Code Blue Pack
10 | Initial Setup
S222 & S222.250 & S222.100 | USER GUIDE
3.3 LOWER BODY ASSEMBLY
1. Unscrew one knob at the end of the
rod that passes through the midsection
by twisting it counterclockwise.
2. Pull the rod out and set it aside.
3. .Connect the hose from the upper
torso to the lower torso
4. Carefully place the lower torso into the
upper torso and align the holes on each
side of the waist to insert the waist rod.
Initial Setup | 11
S222 & S222.250 & S222.100 | USER GUIDE
5. Replace the waist knob and twist it
clockwise to lock it in place.
12 | Initial Setup
S222 & S222.250 & S222.100 | USER GUIDE
3.4 LEG ASSEMBLY
1. To attach the legs, remove the wing nuts,
washers, and springs from the bolts on the hips.
2. Remove the IM pad from each leg and
slide the leg into the hip joint by inserting
the bolt through the orifice in the leg.
3. Assemble the fasteners onto the hip bolt in this
order: washer, spring, washer, and wing nut.
4. Reach through the IM site and tighten the wing
nut until the spring is compressed slightly.
Initial Setup | 13
S222 & S222.250 & S222.100 | USER GUIDE
5. Place the IM pad back on the leg.
3.5 POWERING ON OMNI
1. Connect the power supply to the power jack
NOTE: Always operate Clinical Chloe
with the power supply connected
2. Connect the blue communication
cable to Chloe's left side.
3. Connect the other end of the blue communication
cable to the OMNI Code Blue Pack
14 | Initial Setup
S222 & S222.250 & S222.100 | USER GUIDE
4. The OMNI will proceed to the main
screen after the startup screen.
WARNING: Do not connect the simulator or OMNI to a computer, LAN network
or unauthorized diagnostic equipment using the communication cable (Ethernet
cable). Doing so will cause serious damage to the equipment.
3.6 POWERING ON OMNI 2 (S222.250)
OMNI® 2 controls Chloe’s responses with the touch of
a button. The tablet operates Chloe wirelessly.
Chloe can be operated using a wired
connection. Please refer to the OMNI 2 user
guide to set up a wired connection.
1.
Connect the power supply to the power jack
2.
Turn on OMNI® 2 by pressing and holding the ON
button on the right side of the tablet.
3.
Select “Allow” to turn on Bluetooth for the tablet.
Initial Setup | 15
S222 & S222.250 & S222.100 | USER GUIDE
4.
Follow the on-screen tutorial for a brief overview
of the features of OMNI® 2.
5.
Move onto the next steps in the Tutorial by
selecting “GOT IT”.
6.
Exit the Tutorial at any time by selecting “HOME”
NOTE: Please complete the tutorial once or
it will continue to appear at start-up
After the tutorial, OMNI® 2 will automatically proceed
to the Favorites page and establish a connection to
Clinical Chloe.
WARNING: Do not connect Clinical Chloe
or OMNI 2 to a computer, LAN network or
unauthorized diagnostic equipment. Doing so
will cause serious damage to the equipment.
16 | Initial Setup
S222 & S222.250 & S222.100 | USER GUIDE
4. WORKING WITH CHLOE
4.1 SYSTEMIC
Hygiene
The simulator has a wig that allows for combing,
shampooing and head draping exercises.
Denture Care
• The simulator is supplied with
average size teeth and tongue.
• The upper and lower dentures are removable
and the tongue can be moved side by side.
1. To remove the teeth, insert one finger into the
upper or lower jaw and pull it out gently.
2. To attach the teeth, gently press the denture
into the mouth Velcro side down.
CAUTION: Care must be taken to not damage
the teeth while placing an endotracheal
tube using a conventional laryngoscope. Use
the same caution as with a real patient.
Working with Chloe | 17
S222 & S222.250 & S222.100 | USER GUIDE
Ear, Nose, and Throat
• Left ear: the interior of the ear contains
a simulated ear canal that allows
for ear irrigation exercises.
• Nasal/oral openings are both connected
to the stomach reservoir.
• The nostrils can be pinched for CPR simulations.
CAUTION: Always use the mineral oil
lubricant prior to the introduction of an
endotracheal tube or any other device.
• A gastric reservoir (capacity: 750 ml) is provided,
with an opening connected to the throat.
Bandaging
The toes of the simulator are separated to permit
bandaging exercises. The surface of the simulator is
smooth and resistant to water, oil, and liniments.
18 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
Range of Simulated Movement
The joints are strong and their movements are lifelike
and realistic. The simulator bends at the neck, waist,
knees and ankles and the jaw articulates.
S222 has articulating elbows and wrists.
4.2 AIRWAY
Nasal and Oral Intubation
The simulators’s airway can be intubated through
the left nasal opening, the trachea, and the
mouth using LMA or endotracheal tubes.
WARNING: Always lubricate tubing prior to
performing any nasal or oral intubation
Procedure
Recommended Device Size
Intubation (Blade size)
Miller4 or MAC 3.5
LMA
Size 4
Nasal Intubation
12-16 Fr catheter
Oral Intubation
ETT 7.0 (cuffed) or 7.5 (no cuff)
Working with Chloe | 19
S222 & S222.250 & S222.100 | USER GUIDE
Tracheostomy Care
The simulator is supplied with a
tracheostomy opening.
Pierce the replaceable trachea and insert a
tracheostomy tube. Reseal the trachea with
the tape provided after each exercise.
Surgical Trachea Repair
1.
Gently lift the chest skin of the simulator to reveal
the chest cavity.
2.
Locate the trachea. and remove the tape
enclosing the trachea.
20 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
3.
Use the provided tape to replace the pierced
tape and re-seal the trachea.
NOTE: Air leaks in the airway will result
in poor chest rise during ventilation
and false intubation readings.
4.
Lay the cehst skin over the torso and reattach
with Velcro.
Artificial Ventilations
Use a normal size adult BVM which will seal around
the mouth and nose.
The ribs have normal anatomic landmarks and the
lungs expand normally permitting realistic chest rise.
WARNING: Do not perform mouth to mouth
ventilation with a protective barrier. Doing so
may lead to contamination of the airway. The
airway itself cannot be sanitized or cleaned
Ventilations are measured and logged.
It is recommended to calibrate the ventilations before
performing ventilations (for OMNI).
Working with Chloe | 21
S222 & S222.250 & S222.100 | USER GUIDE
Ventilation Calibration OMNI
1. Press the button that reads "CALIB"
2. Select "V CAL"
3. Press "START"
4. When OMNI® is ready to calibrate,
it will display VENTILATE.
5. Follow the cues on the screen to perform
one ventilation at a time, until finished.
22 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
6. Perform a total of 5 ventilations
7. Press “SAVE” to store the calibration
Chest Compressions
Chest compressions are measured and logged,
showing the instructor exactly how facilitators are
performing.
It is recommended to calibrate the compressions
before performing compressions.
Chest Compression Calibration OMNI
1. Press the button that reads “CALIB”
2. Select “C CAL.”
Working with Chloe | 23
S222 & S222.250 & S222.100 | USER GUIDE
3. Press "START"
4. When OMNI® is ready to calibrate,
it will display COMPRESS.
5. Follow the cues on the screen to perform
one compress at a time, until finished.
6. Perform a total of 5 compressions
7. Press “SAVE” to store the calibration
24 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
Chest Compression Calibration OMNI 2
1. Make sure your simulator is connected to OMNI 2
2. Tap the gear icon on the upper-
right corner of the screen.
3. Select "Calibration"
4. Select “Compression”
5. Press START and complete 5 chest compressions.
Working with Chloe | 25
S222 & S222.250 & S222.100 | USER GUIDE
6. Press "SAVE" when finished.
4.3 CIRCULATION
Connecting the Pulse Line
1. Connect the pulse line by unscrewing the red cap.
2. Twist the pulse line with the squeeze bulb
attachment onto the pulse line port.
Generating Pulses
• The simulator produces bilateral
carotid and right radial pulses by
manually pumping the squeeze bulb
26 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
Intramuscular (IM) Injection Site
IM injection sites are for placement practice only. Do not inject fluids into the IM
sites when simulating intramuscular and subcutaneous injections.
Both deltoids
Both quadriceps
Left upper buttock
The IM site is a consumable item. To replace
the injection pads, lift the IM injection pad and
insert the new one by gently pressing it down.
Working with Chloe | 27
S222 & S222.250 & S222.100 | USER GUIDE
4.4 INTRAVENOUS (IV) ARM (S222.100)
• The IV right arm can be used for infusion,
blood collection, intravenous injection,
intramuscular injection, TB screening,
and subcutaneous injection exercises.
• The arm and hand contain venous grooves, fitted
with soft latex tubes to simulate the consistency
of veins. Covering the venous structure is a
pliable vinyl skin that is removable and washable.
NOTE: Always flush the IV system with distilled
water at the end of every simulation.
CAUTION: Use only Gaumard’s provided simulated blood. Any other simulated blood brand
containing sugar or any additive may cause blockage and/or interruption of the vasculature.
IV Arm Package
1. Simulated blood concentrate
2. Spare arm skin
3. Blood dispensing bag
4. Metal stand
5. Mineral oil
6. Baby powder
7. Syringe
8. Funnel
Filling the IV Arm with the Dispensing Bag
One way to fill the IV arm is using a blood dispensing bag which is helpful in
simulating continuous infusion and multiple blood collection exercises.
1. Place the blood dispensing bag on the stand.
28 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
2. Remove the IV caps on the shoulder and connect
the fill tube and drainage tube to the shoulder.
3. Connect the drainge tube.
4. Connect the fill tubing.
5. Close the clamp on the drain tube
Working with Chloe | 29
S222 & S222.250 & S222.100 | USER GUIDE
6. Attach the fill tube to the bottom port
of the blood dispensing bag and place
the drain tube inside a container.
7. Add water or simulated blood to the
blood dispensing bag using the funnel
provided or the large syringe.
8. Unclamp the tube connected to the
bottom of the blood dispensing bag to
allow fluid to flow through the system
and into the drainage container
9. Close the drainage tube's clamp when there
are no more air bubbles in the tube.
30 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
10. Place the black rubber stopper on the
upper port of the blood dispensing bag.
Venous Pressure
• To vary the pressure in the vasculature of the
arm, attach the squeeze bulb to the blood
dispensing bag and clamp the drainage tube.
• Squeeze the bulb to inflate the bag and
create the desired pressure in the veins.
• To simulate a clenched fist or bulging
veins, clamp the drainage tube and apply
pressure using the squeeze bulb.
• To simulate collapsed veins, release the air
pressure by loosening the squeeze bulb's valve.
• Place the black rubber stopper on the
upper port of the blood dispensing bag.
Working with Chloe | 31
S222 & S222.250 & S222.100 | USER GUIDE
Filling the IV Arm with the Fill Kit
Another way to fill the venous system is with the use of the drainage tube and the fill kit syringe.
1. Unscrew the caps from the shoulder.
2. Connect the drainage tube to the
shoulder port and leave it unclamped.
3. Fill the fill syringe with the desired fluid
- simulated Gaumard blood or water.
4. Connect the fill syringe to the
other shoulder port.
32 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
5. Push the fluid into the system.
6. Push fluid into the system until air
bubbles no longer appear in the
drainage tube then clamp the tube.
Draining the Venous System Through the Dispensing Bag
If the use of the blood dispensing bag was used for an IV arm exercise follow the steps below to drain the system.
1. Unclamp the drainage tube.
2. Replace the black rubber stopper
with the squeeze bulb.
Working with Chloe | 33
S222 & S222.250 & S222.100 | USER GUIDE
3. Squeeze the bulb to push the remaining
fluid out of the venous system.
4. Remove the squeeze bulb.
Using the funnel, fill the dispensing bag
with a 70:30 mix of water to Isopropyl
alcohol in order to flush the fluid system.
5. Replace the funnel with the squeeze
bulb and squeeze the remaining fluid
out through the drainage tube. Once the
venous system is purged, push air through
the system using the squeeze bulb.
34 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
Draining the Venous System with the Fill Kit
If the venous system was filled using the fill kit syringe, follow the steps below to drain the system.
1. Fill the syringe with a 70:30 mix
of water to isopropyl alcohol and
connect to the shoulder port.
2. Make sure the drainage tube is open and
push the fluid through the arm until the
fluid coming out of the arm is clear
3. Inject air through the arm to dry the
vasculature and prevent mold from forming.
NOTE: Drain and flush the venous system with
clean water after each day of simulation.
4.5 REPLACING THE IV ARM SKIN (S222.100)
1. Gently lift the arm skin that meets at
the seam of Chloe's upper arm.
Working with Chloe | 35
S222 & S222.250 & S222.100 | USER GUIDE
2. Apply a small amount of talcum
powder or mineral oil to the arm
3. Slide the new arm skin onto the arm.
TB Screening Sites
There are 2 TB sites on the arm that may be utilized
for TB screening.
36 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
Perform the TB tests in the sites highlighted below.
4.6 BREAST EXAMINATION
One of the female breast will have a
simulated lump for palpation exercises.
Chloe is provided with a set of male
and female breast inserts.
Working with Chloe | 37
S222 & S222.250 & S222.100 | USER GUIDE
Abnormal Interchangeable Breast Package (S222.100)
1. Interchangeable abnormal breast (set of 7)
2. Palpation brassiere
3. Lymphatic drainage overlay
Interchangeable Breasts:
Breast #1
Demonstrate and practice the movement
of the mammary gland on the surface
of the pectoralis major muscle.
Breast #2
Seven discreet nodes on one side, a somewhat
larger node on the other side, and a very
discreet puckered area around the nipple. This
breast represents various stages of fibrocystic
disease. The larger node may be felt either as
a hard node or as a cystic mass or swelling.
38 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
Breast #3
There is a solitary tumor in the breast below. It is
well circumscribed and has a stalk. The tumor can
be moved, and is not adherent to breast tissue.
Breast #4
This breast shows a retracted nipple and on careful
palpation, a mass may be felt immediately under
the nipple. This breast represents a carcinoma in
one of the milk ducts and also shows the so-called
“orange skin” effect on the entire nipple area.
Attach the Velcro on the nipple to the
Velcro on the inside of the brassiere.
Breast #5
The breast here shows a comparatively rare
but easily palpable tumor: a giant sarcoma (or
giant mammary myxoma) of which the wildly
growing masses (the largest one shown in
ulcerated form) can be easily felt and seen.
Breast #6
This form of breast cancer (scirrhous carcinoma).
When palpating, note the infiltrating nature
of the growth. It has no well-defined borders
and cannot be moved within the breast.
Working with Chloe | 39
S222 & S222.250 & S222.100 | USER GUIDE
Breast #7
Place the mastectomy breast under the lymphatic
drainage breast to palpate and identify a
mastectomy.
This replica of the lymphatic drainage of the left
breast outlines the various pathways along which
breast tumors metastasize. The auxiliary pathway,
subclavian pathway, and internal mammary pathway
are shown and are easily palpable.
Changing Breasts for Palpation Exercises
1. Place the simulator in a semi-upright position
and gently lift the breast and set it aside.
2. Chose the desired breast and place
it on the chest Velcro side down
and gently press it in place.
3. Attach the soft vinyl brassiere onto the torso
securing it down gently with the Velcro.
40 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
4.7 GASTROINTESTINAL
Internal Reservoir Capacity
Reservoir
Capacity
Stomach
200 mL
Bladder
1500 mL
Rectum (Colostomy)
1500 mL
Stomas
350 mL
1
2
3
1. Ileostomy
2. Suprapubic Cystostomy
3. Transverse Colostomy
Stomach and Liver
A gastrostomy left port, located near the
waist, connects directly to the stomach tank.
Gastric Feeding and Suctioning
1. To fill the stomach reservoir for gastric feeding
and suctioning, attach the funnel to the
gastronomy port located at the waist and fill
the reservoir with up to 200 mL of fluid.
NOTE: Use a 12-16 Fr sized catheter for
nasogastric tube feeding and gastric suctioning.
2. When the procedure is complete,
you may collect any remaining fluid
with the same suctioning tool.
Working with Chloe | 41
S222 & S222.250 & S222.100 | USER GUIDE
Stomas, Rectum, and Suprapubic Cystostomy
The simulator has anatomically sculptured stomas of
ileostomy and suprapubic cystostomy.
Practice skin preparation, stoma hygiene, treat
conditions around the site, and apply disposable or
permanent ostomy bags to the openings.
Stomas
• To fill the ileostomy reservoir, use the
fill kit syringe inject up to 350 mL of
fluid into the indicated fill port.
4.8 CATHETERIZATION
Procedure
Recommended Device Size
Capacity
Catheterization
18 Fr
1500 mL
Filling the Bladder
Chloe has a simulated bladder and female genitalia to practice catheterization procedures.
1. Remove the suprapubic stoma
42 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
2. Insert the funnel or the fill kit syringe
into the suprapubic port.
3. Fill the bladder reservoir with
up to 1500 mL of fluid.
4. Once filled, insert the urethra plug
into the suprapubic port.
Increasing Urinary Flow
1. Use the squeeze bulb located on the right side of
the lower torso to inflate the internal cushion.
This will lift the bladder and will increase bladder
pressure and which intensifies the urinary flow.
Female Catheterization
• Make sure to catheterize the
simulator while it is on its back.
1. Insert the urethra plug.
Working with Chloe | 43
S222 & S222.250 & S222.100 | USER GUIDE
2. Ensure the female red adapter
is in the urethra passage
3. Lubricate the catheter with provided mineral oil
4. Insert the catheter
Male Catheterization
1. To attach the male genitalia, remove
the red adapter connected to the
urethra passage and set it aside.
NOTE: Do not discard the adapter
as it is necessary to perform female
catheterization exercises.
44 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
2. Slide the tube attached to the male
genitalia into the opening of the urethra
on the simulator, and gently press down
on the Velcro to secure it in place.
3. Lubricate the catheter before insertion.
NOTE: Catheterize the simulator in an
upright recumbent position. Catheters
smaller than 18 Fr may cause leakage.
Draining the Bladder Reservoir
There are several ways to empty
the bladder reservoir:
• Sit the simulator over a bedpan with a
catheter in place, and squeeze the squeeze
bulb on the right side to push the fluid out.
• Remove the waist rod separating the upper
torso from the lower torso, and squeeze
the fluid out from the bladder reservoir.
NOTE: Refer to Section 7. Routine Maintenance
to flush the bladder reservoir.
Working with Chloe | 45
S222 & S222.250 & S222.100 | USER GUIDE
4.9 ENEMA
• The legs of the simulator articulate
and permit enema administration.
• Use the small anal nozzle provided to fill
the enema reservoir with up to 1500 mL.
• A non-return valve is built into the anal
canal to prevent fluid from escaping.
4.10 ULCERS
Two types of decubitus ulcers are
provided with the simulator:
1. Initial stage of ulceration
2. Suppuration or pus/deeply infected stage
Diagnose and treat ulcers on the left foot of the
simulator.
NOTE: This feature is optional for the S222 and
S222.250.
46 | Working with Chloe
1
2
S222 & S222.250 & S222.100 | USER GUIDE
4.11 GYNECOLOGIC EXAMINATION
Chloe allows for vaginal douching and pap smear exercises with a realistic vagina and cervix
GYN TRAINING (S222.100)
• Bimanual pelvic examination, including
palpation of the normal and abnormal uteri
• Vaginal speculum examination
• Visual recognition of normal and
abnormal cervical disorders
• Uterine sounding
• IUD insertion and removal
• Diaphragm sizing and fitting
• Recognition of early pregnancy
Gynecologic Package
1. Normal anteverted uterine assembly
2. Normal cervices
3. Spare locking ring
4. Abdnormal cervices
5. 10 week pregnant uterus
6. 10 week pregnant cervix
4.12 AMPUTATION STUMP
The Amputation Stump is part of the standard
package for the S222 and S222.250
Working with Chloe | 47
S222 & S222.250 & S222.100 | USER GUIDE
1. To attach the amputation stump, remove the
lower leg by unscrewing the bolts at the knee
joint using the hexagonal wrenches provided.
2. Attach the amputation stump by
inserting it over the knee joint.
48 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
5. OPTIONS
5.1 HEART AND LUNG SOUNDS FEATURE (S222.100)
The heart and lung sounds feature is standard for the S222.100 and optional for the S222 and S222.250.
The Heart and Lung Sounds teaching system is a tool used for auscultation training. The system is composed of a
Virtual Stethoscope™ and Radio Frequency Identification (RFID) sensors located beneath the skin of the simulator.
The Virtual Stethoscope has incorporated:
• Power button
• Sound menu button
Features
The torso of the simulator has numerous removable
identification dots located where each of the
heart and lung sounds are normally heard. These
colored dots can be removed at any time to
find the auscultation sites on the front and the
back of the simulator. Each auscultation location
relates to the physiology of the torso. Batteries
for the Virtual Stethoscope are included.
Setup
1. Unscrew the top cover of the stethoscope bell.
2. Remove and discard the plastic insert
separating the two batteries prior to first use.
3. Locate the small stereo jack on the bell and
attach it into the speakers provided. Plug
the speakers into a conventional 120V/60
Hz wall outlet and turn the speakers on.
NOTE: Refer to the Virtual Stethoscope user
guide for more details to use the system.
Working with Chloe | 49
S222 & S222.250 & S222.100 | USER GUIDE
Heart and Lung Sounds Menu
LOCATION
SOUND
DESCRIPTION
Base Sound
Patient has a normal heart with mild anemia. The
heart is hyper-dynamic and has elevated cardiac
output. S2 is accentuated at the base.
Fixed Split S2
Patient has an atrial septal defect which increases flow through the
right heart, prolongs RV systole and also produces a mid-systolic
murmur (MSM) because of increased flow through the RV outflow tract.
Base Right
Physiological
Base Left
Split S2
Split S2
Paradoxical
Split S2
Left Side Sternal
Border
The splitting of S2 is easily heard during inspiration and
the second sound is single during expiration. The second
component of the split sound (P2) is accentuated.
S2 is variably split during mid-inspiration, as three beats are repeated.
The splitting of S2 is heard during expiration, but
the sound becomes single during inspiration. The
background noise is increased during inspiration.
Opening Snap
Patient has mitral stenosis, responsible for an early crisp
diastolic sound heard at the base 0.08 seconds after S2. S1 is
usually loud at the base, which reflects mitral stenosis.
Friction Rub
Patient has uremic pericarditis, which leads to rubbing of
roughened visceral and parietal pericardial surfaces against one
another. The 3 component rub exists during deep inspiration.
Apex Sound
Patient has a normal heart with mild anemia. The heart
is hyper-dynamic and has elevated cardiac output.
Mid- Systolic Click Patient has mitral prolapse, which produces a midsystolic click heard during inspiration.
S3 Sound
Apex
Patient has a readily heard third heart sound. S3
occurs later in diastole than the opening snap.
Patient has left ventricular hypertrophy, and has a fourth sound
Intermittent S4
Starr-Edwards
Valve
(S4) which is not heard on every cycle. The sound
is presystolic, about 0.1 second before S1.
This ball-in-cage mitral prosthesis has a mechanical
closing sound (S1) and one or more diastolic sounds
caused by the ball bouncing within the cage.
Tracheal Sounds
Expiration sounds are louder, have a higher pitch, and are of longer
duration than during inspiration. The silent period or pause following
expiration is longer than the one between expiration and inspiration.
Stridor Sounds
Patient has marked respiratory distress, and a narrow
aperture between the vocal cords that produces a high
pitched tone during both inspiration and expiration. During
the end of expiration, there is an abrupt drop in pitch.
Trachea
50 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
LOCATION
SOUND
DESCRIPTION
Bronchial Sounds
Breath sounds are similar to tracheal sounds in that the
expiratory phase is louder and lasts longer than the
inspiratory phase. The major distinguishing characteristic is
the high pitched, harsh quality of the expiratory phase.
Wheezing Sounds
These musical wheezing sounds are often heard in asthma
patients. During inspiration, the wheeze is slightly higher in
pitch than during expiration. Wheezing in asthmatics is often
present in either one or both phases of respiration.
Bronchial Sounds
Breath sounds are similar to tracheal sounds in that the
expiratory phase is louder and lasts longer than the
inspiratory phase. The major distinguishing characteristic is
the high pitched, harsh quality of the expiratory phase.
Wheezing Sounds
These wheezing sounds are often heard in asthma patients.
During inspiration, the wheeze is slightly higher in pitch
than during expiration. Wheezing in asthmatics is often
present in either one or both phases of respiration.
Pleural Friction
This sound originates from the friction of inflamed pleural
surfaces moving against one another. The sound is repetitive
as long as the breathing pattern and position remain
constant. Similar to but lower in pitch than crackles.
Upper Anterior
(2 sites)
Lower Anterior
(2 sites)
Posterior (4 sites
Medium-fine
Crackles
These noises begin about mid-inspiration and progressively increase
in intensity up to the end of expiration. Coarse crackles are also
audible in the early expiratory phase of some of the breaths.
Rhonchi Crackles
Coarse crackles are present during both inspiration and
expiration. There are also some very low pitched repetitive
sounds that are rhonchi. High pitched squeaks are also
audible against a background of bronchial breath sounds.
Coarse Crackles
Coarse crackles begin at the onset of inspiration
and diminish in intensity and prevalence toward the
end of inspiration. Expiration is not audible.
Posterior (4 sites)
Coarse and medium crackles appear toward the end of
Pulmonary Edema inspiration and continue into expiration. The respiratory rate
is rapid and expiratory phase is “bronchial” in character. These
features exist during respiratory distress and congestion.
Working with Chloe | 51
S222 & S222.250 & S222.100 | USER GUIDE
5.2 BLOOD PRESSURE LEFT ARM (S222.100)
The Blood Pressure Training System consists of a full-size adult left arm. This is a versatile training tool developed
to assist health professionals teach the processes and skills required to perform blood pressure auscultation
procedures and techniques.
Palpable Pulses
Programmable, palpable radial pulse is present when the cuff pressure
is less than the selected systolic blood pressure.
Korotkoff Sounds
Korotkoff sounds, K1 through K4 (K5 is silent) are audible between systolic and diastolic pressures.
Depending on the selected heart rate and the rate of cuff deflation, the Korotkoff sounds will adjust
automatically. The sounds are silenced automatically if the auscultatory gap is enabled.
Auscultation
The simulator operates with a modified blood pressure cuff. Connect the BP cuff extension to the arm’s control
panel before use. Use a conventional stethoscope to auscultate Korotkoff sounds in the antecubital area.
BP Cuff Setup
1. Connect the simulator to the OMNI
2. Wrap the modified blood pressure
cuff around the arm above the elbow
as you would a real patient.
NOTE: Make sure to orient the cuff where the
arrow on the cuff points towards the elbow.
3. Connect the BP cuff extension to the
adapter labeled BP on the control panel.
52 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
4. Connect the speakers to the port on the shoulder
Blood Pressure Calibration with OMNI
It is recommended to calibrate the
blood pressure arm before use.
1. On the OMNI device select "BP ARM"
2. To calibrate, select “CALIB”
3. Press “NEXT” to continue
NOTE: OMNI will prompt you to hold the
BP cuff at a certain pressure to calibrate
4. Hold the pressure of 0mmHg and
press the “NEXT” button
Working with Chloe | 53
S222 & S222.250 & S222.100 | USER GUIDE
5. Hold the BP cuff pressure at
20mmHg and press “NEXT”
6. Continue until the pressure reaches 300mmHg
After calibrating, OMNI will return to the main screen
and display the reading on the sphygmomanometer.
NOTE: Refer to the section "Working
with OMNI Code Blue" and "BP Arm" for
more information on using OMNI.
BP Arm OMNI® Menus
• Use the BP Arm menu to gain access to
additional settings, feedback graphics
and navigation menus that control all the
features of the blood pressure arm.
CURRENT SETTINGS
Current settings information is listed
on the top portion of the screen.
54 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
FEEDBACK GRAPHICS MENU
The feedback graphic displays the BP cuff pressure
in real time at the bottom of the screen.
NAVIGATION SUBMENUS
Edit BP settings using the navigation menus. Select
a menu item by pressing the soft key buttons
located on the right side of the controller. Each
menu has additional submenus. Use the submenus
to decrease, increase, accept, or cancel values.
Set BP
Use this menu to set the blood
pressure in the simulator.
Select systolic or diastolic and adjust the
pressure using the + and - buttons.
Press OK to save the changes and
return to the previous screen
Pulse
Use this menu to set the heart rate. Adjust the
beats per minute using the + And - buttons.
Press OK to save the changes and
return to previous screen.
Working with Chloe | 55
S222 & S222.250 & S222.100 | USER GUIDE
AU. Gap
Enable and set an interval of pressure
where Korotkoff sounds dissipate. The
auscultatory gap is disabled by default.
Pressing the Enable button activates the
UPPER and LOWER menus. Use these menus
to set the limits of the auscultatory gap.
Adjust the limits of the auscultatory
gap using the + And - buttons.
Press OK to save the changes and return to previous
screen. The default upper and lower limits for the
auscultatory gap are 100 mmHg and 90 mmHg.
Volume
Increase or decrease the volume of Korotkoff
sounds using the VOLUME menu.
Press OK to save the changes and return
to the previous screen. The default value
for the Korotkoff sounds volume is 5.
56 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
5.3 BLOOD PRESSURE LEFT ARM (S222.250)
BP Cuff Calibration
1. Follow the instructions in Section 7.1 "BP Arm
Setup" and connect the OMNI® 2 tablet.
2. Tap the Menu icon, then select “Calibration”
3. The Calibration screen will appear. Select
“Left Blood Pressure” to begin.
4. Tap on START to begin Calibrating. Set
the BP cuff pressure to the values on
the screen starting with 0 mmHg.
Working with Chloe | 57
S222 & S222.250 & S222.100 | USER GUIDE
5. Increase the BP cuff pressure when the display
prompts you to inflate the cuff one value at a
time. Continue to tap "SET" after setting each
increment.
The OMNI 2 will prompt you to increase the
BP cuff pressure from 0 to 300 mmHG.
6. Tap “SAVE” at the end of the calibration process.
NOTE: It is not necessary to recalibrate the
BP Arm for each training session. The OMNI 2
controller will remember the calibration settings.
Adjusting the Blood Pressure
1. To adjust the BP, tap the “Vitals” page.
2. Tap “Blood Pressure” and use the top slide
bar or the + or – sign to increase or decrease
the systolic value. Use the bottom slide bar
to increase or decrease the diastolic value.
58 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
3. Tap on “APPLY NOW."
Auscultatory Gap
1. To turn on auscultatory gap, tap on the
“Vitals” page then select “Auscultatory Gap”
and slide the ON/OFF button to ON.
2. To increase or decrease the High Gap and
Low Gap, slide the top and bottom bars
left or right, or tap the + or – buttons.
3. Tap APPLY NOW to apply it instantly.
Working with Chloe | 59
S222 & S222.250 & S222.100 | USER GUIDE
4. . The auscultatory gap will appear in gray on
the manometer in the “Blood Pressure” page.
60 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
5.4 GERIATRIC FACE SKIN
The geriatric face skin accessory is designed to expand the breadth of the learners’ experiences and aid educators
in teaching patient-centric assessment and care skills. Easily and quickly convert Clinical Chloe's face and hair
to that of an elderly patient for geriatric scenario-based simulations and skill training exercises. The package
includes a removable geriatric face skin and a removable wig.
Clinical Chloe has been built with her standard wig attached using Velcro to be compatible with this Geriatric
Face Skin option, starting at the following serial numbers:
• S222: CPR-22607910
• S222.100: CPR-22607908
• S222.250: CPR-23608900
If your simulator’s serial number is less than the serial numbers listed above, please contact technical support for
instructions on how to make your simulator compatible with this option.
To interchange your Clinical Chloe's wigs and utilize the Geriatric Face Skin:
1.
Insert your fingers along Chloe’s hairline and
detach the wig from its Velcro.
2.
Unzip the back of the Geriatric Face Skin.
Working with Chloe | 61
S222 & S222.250 & S222.100 | USER GUIDE
3.
Flip the Geriatric Face Skin inside out and begin
placing it over the face of the simulator.
4. Fit the Geriatric Face Skin to the whole head of
the simulator and smooth the skin towards the
back of the head so the zipper can be aligned.
5.
Zip the back of the Face Skin.
6. Fit the elderly wig to the head of the simulator,
if using it. If you would like to simulate an elderly
male patient, simply forgo the wig.
RECOMMENDATION: At the end of the simulation day remember to remove the Geriatric Face
Skin accessory and store in a temperature regulated location as you would your simulator.
62 | Working with Chloe
S222 & S222.250 & S222.100 | USER GUIDE
6. WORKING WITH THE OMNI® CONTROLLER
6.1 OMNI® CONTROLLER FEATURES
OMNI® Code Blue is a CPR training tool designed to help teach CPR by monitoring
cadence and depth of compressions as well as airway ventilations in real time.
eCPR
• eCPR is an application that enables monitoring and logging of compressions
and ventilations, performed in real time by the user, on a PC.
• This software aims to provide additional testing and teaching tools for CPR using
an interface to display a waveform graph of the compressions and ventilations.
• For instructions on how to use eCPR, please refer to the OMNI® User Guide.
Startup Screen
The OMNI® startup screen is divided into
three sections: Feedback Graphics, Current
Settings, and Navigations Menus.
Feedback Graphics
Monitor and evaluate depth and cadence of
compressions and ventilations in real time.
Current Settings
The current settings are listed on the middle
of the screen. The settings will reflect the
information saved during a previous session.
Working with The OMNI® Controller | 63
S222 & S222.250 & S222.100 | USER GUIDE
Navigation Menus
• Edit the simulator settings using
the navigation menus.
• Select a menu item by pressing the soft
key buttons located on the right side of
the controller. Each menu has additional
submenus or toggle selections.
• Use the submenus to decrease,
increase, accept, or cancel values.
• Use the toggle selection to switch
between available options n the menu.
6.2 NAVIGATION SUBMENU
MODE
• This submenu is for the CPR operational mode.
Switch between TEST and COACH mode.
• The COACH mode generates audible tones to
coach CPR ratio. A high-pitched beep signals
the care provider to perform a compression
and a low pitched beep signals a ventilation.
• Tap on MODE to switch to TEST mode to
perform CPR without the audible cues.
C:V RATIO
• Customize the compression to ventilation
ratio to match correct guidelines.
• Adjust the compression to ventilation ratio
using the + And - buttons. Press OK to save the
changes and return to the previous screen.
• The default value for the C:V Ratio is
3 compression to 1 ventilation.
64 | Working with The OMNI® Controller
S222 & S222.250 & S222.100 | USER GUIDE
CMR RATE
• This submenu is for adjusting the number of
compression and ventilations per minute.
• The default value for the compression
rate is 100 compressions per minute.
Adjust rate using the + and - buttons.
• Press OK to save changes and
return to previous screen.
• The compression rate limit is 50 - 150
CPM. the ventilation rate is 2 - 60 VPM.
CALIB.
• This submenu is to calibrate the
pressure sensor in the simulator.
• Press CALIB. to access additional
calibration menu selections.
• See section 4.2 for instructions to
calibrate ventilations and section
4.3 to calibrate compressions.
RESET PRESSURE SENSOR
• It is recommended that the OMNI® controller’s
pressure sensor is reset at altitudes
greater than 1000 ft. to avoid inaccurate
compression and ventilation readings.
• Perform the sensor reset procedure as
part of the initial calibration process.
1. Select RESET within the compression or
ventilation calibration menu.
After resetting the sensor, OMNI®
will display DONE.
2. Select SAVE to finish
Working with The OMNI® Controller | 65
S222 & S222.250 & S222.100 | USER GUIDE
HELP
The help window provides access to
global settings such as backlight time and
OMNI® and Simulator serial number.
BACKLIGHT
• The default value for OMNI®'s backlight
timer is 10 minutes. After 10 minutes
the backlight will turn off.
• To increase the backlight duration, adjust
the backlight timer with the plus or minus
sign. Press OK to accept the changes.
SERIAL NUMBER
View OMNI® and Simulator serial number.
Press OK to return to the HELP menu.
66 | Working with The OMNI® Controller
S222 & S222.250 & S222.100 | USER GUIDE
7. WORKING WITH THE OMNI®2 TABLET
7.1 OMNI®2 TABLET FEATURES
• Operate OMNI 2 with a wireless
range of up to 30 ft.
• The home screen consists of the Favorites page,
Vitals page, CPR page, and Blood Pressure page.
• Reference the OMNI 2 user guide provided
for more details to navigate each page
• The session time will run automatically once
the tablet is on. Reset the session by tapping
“Reset Session Time” in the Menu page.
FAVORITES PAGE
• The Favorites page consists of the
most commonly used vital signs
• Reference the OMNI 2 user guide provided
to edit the vitals shown on this page.
Working with The OMNI®2 Tablet | 67
S222 & S222.250 & S222.100 | USER GUIDE
VITALS PAGE
The Vitals Page includes Breathing, Cardiac,
and Circulation. Each change in vitals can
be applied instantly or added to a queue.
CPR PAGE
• The CPR page includes feedback for compression
rate and depth, and ventilation duration and PIP.
• Use the metronome on this page
to coach the provider.
eCPR
• To begin and end a CPR session, tap on the
CPR icon and the START/STOP button.
• To reset a CPR session, tap the Reset icon.
• To activate an audible rhythm to
aid in compression training, tap
on the metronome button.
NOTE: CPR settings are AHA
compliant by default.
• To monitor and evaluate chest compressions
in real time, follow the steps in the
OMNI 2 user guide provided.
68 | Working with The OMNI®2 Tablet
S222 & S222.250 & S222.100 | USER GUIDE
MANAGE PROVIDERS
• This tab allows the facilitator the
ability to add, record, and evaluate
provider actions during a session.
• Add a group of providers to track actions
of each individually. This feature records
the name of the provider and their
action as an event entry in the log.
LOG
• View event log and filter based on the event.
• Add notes during debriefing
and save or print the log.
7.2 BATTERY USAGE
• The battery life of the OMNI 2 tablet
is displayed on the top right
Working with The OMNI®2 Tablet | 69
S222 & S222.250 & S222.100 | USER GUIDE
7.3 TURNING OFF THE SIMULATOR
1. Disconnect the power supply from the simulator
and hold the power button on the tablet.
2. Select “Power Off”
3. Tap on “OK” to shut down the tablet.
70 | Working with The OMNI®2 Tablet
S222 & S222.250 & S222.100 | USER GUIDE
8. ROUTINE MAINTENANCE
8.1 FLUSHING THE FLUID RESERVOIRS
It is good practice to flush the fluid reservoirs periodically to prevent mold from forming.
1. To reach the reservoirs, loosen the waist
knobs and remove the waist rod.
2. Disconnect the hose from the upper torso.
3. Remove the support insert and set it aside.
Routine Maintenance | 71
S222 & S222.250 & S222.100 | USER GUIDE
4. Remove the waist tube and set it aside.
5. Remove the foam insert from the lower abdomen.
6. After flushing the reservoirs, replace the
foam insert, connect the waist tube, and
reattach the upper and lower torso as directed
in section 3.3 Lower Body Assembly.
Stomach Reservoir
1. Disconnect the white port from
the stomach reservoir.
72 | Routine Maintenance
S222 & S222.250 & S222.100 | USER GUIDE
2. Remove the stomach reservoir
Ileostomy Reservoir
1. Gently disconnect the ileostomy port and
the ileostomy site clips to release the bag.
2. Inject a 30:70 mix of isopropyl alcohol to water
and squeeze the bag over a container or sink.
3. Insert the clips to the ports to reattach the bag.
Bladder Reservoir
1. Gently disconnect the bladder port
and the suprapubic Cystostomy
site clips to release the bag.
Routine Maintenance | 73
S222 & S222.250 & S222.100 | USER GUIDE
2. Inject a 30:70 mix of isopropyl alcohol to water
and squeeze the bag over a container or sink.
3. Insert the clips to the ports to reattach the bag.
Colostomy Reservoir
1. Gently disconnect the rectal port and the
transverse colostomy site clips to release the bag.
2. Inject a 30:70 mix of isopropyl alcohol to water
and squeeze the bag over a container or sink.
3. Insert the clips to the ports to reattach the bag.
74 | Routine Maintenance
S222 & S222.250 & S222.100 | USER GUIDE
9. TROUBLESHOOTING
9.1 OMNI® IS NOT TURNING ON
Probable Cause
Power supply may not be
connected to the simulator
Solution
Make sure the power supply cable is connected
Communication cable is not
connected to OMNI® or the
Connect the communication cable to the simulator and to OMNI®
simulator
9.2 CONNECTIVITY TO THE SIMULATOR CANNOT BE
ESTABLISHED OR IS LOST
Probable Cause
Corrupted OMNI® connection
OMNI®'s data cable is not
connected
Solution
Reboot OMNI® by unplugging the communication cable and reconnecting
after a few seconds
Ensure the Ethernet cable is plugged into OMNI® and the simulator
Verify the power cable is connected to the simulator
OMNI®2 tablet is too far away from Minimize the distance between the tablet and the simulator.
the simulator
More than one device is paired
The simulator is not paired
Power supply is not connected to
the simulator
The distance should not be more than 12 meters away.
Open the Bluetooth connection setup.
Select the menu icon and tap “Forget” for the unwanted connection.
Tap the Menu icon and select "Bluetooth Connection Setup and tap the
serial number. It will appear under "Paired devices."
Ensure that the power supply is connected to the simulator
Troubleshooting | 75
S222 & S222.250 & S222.100 | USER GUIDE
9.3 OMNI® OR OMNI®2 IS NOT DETECTING ANY
COMPRESSIONS OR VENTILATIONS
Probable Cause
Solution
System is not calibrated
Calibrate compressions and ventilations using
9.4 OMNI®2 TAKES TOO LONG TO BOOT UP
Probable Cause
A system restore is required
Solution
1. Unplug the communication cables from OMNI®
2. Press and hold down the two outer keys located on the right side of
the controller, while reconnecting the communication cable.
3. Once the “please wait” message appears on the
screen, release the two outer keys.
4. Wait for the main screen to load and continue with simulations.
9.5 CPR IS NOT DETECTED IN OMNI®2
Probable Cause
Solution
Reset the compression sensor
Tap the menu icon, then tap on “Reset Compressions Sensor”
Reset the ventilations sensor
Tap the menu icon, then tap on “Reset Ventilations Sensor”
Review the OMNI®2 user guide for the most common trouble shooting topics regarding the OMNI®2 tablet.
76 | Troubleshooting
S222 & S222.250 & S222.100 | USER GUIDE
10. APPENDIX
10.1 CONSUMABLE PARTS LIST
Product
Item Number
Arm Skin
S222.813R.IV.L/S222.100.813R.IV.L
Dispensing Blood Bag
S222.811/S222.100.811
Artificial Blood Concentrate
S222.812/ S222.100.812
Sub-Q Injection Site
S222.100.834
IM Injection Site
S222.100.857
Lubricant
S222.974/S222.100.181
10.2 SUPER CHLOE AND CLINICAL CHLOE FEATURES
FEATURES
S222.100
S222.250/
S222
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
GENERAL PATIENT CARE
Bathing and bandaging activity
Full body
Eyes open and close ophthalmic exercises (one pupil is dilated)
Realistic urethral passage and bladder for catheterization exercises
Upper and lower dentures for oral hygiene
Soft, realistic face, skin, hands, feet, fingers, and toes
Simulated ear canal for otic drops and irrigation
Colostomy and ileostomy stomas to practice irrigation
Opening for gastrointestinal procedures
Enema administration capability
Stylish wig for hair care exercises and surgical draping
Amputation stump
Set of two decubitus ulcers
Ulcerated foot
Manual palpable pulses
Interchangeable male and female organs (Both included)
Blood pressure arm with real-time feedback
ARTICULATION
Head and jaw
Elbows and wrists
Knees and ankles
INJECTION TRAINING
Intramuscular injection sites in arm, thighs, and buttock
Advanced training arm and hand for IV, IM, and sub-Q techniques
Appendix | 77
S222 & S222.250 & S222.100 | USER GUIDE
HEART AND LUNG SOUNDS
Site specific heart and lung sounds with Virtual Stethoscope
BREAST PALPATION
Interchangeable male and female breast inserts
Breast palpation capability with 7 abnormal breast
Breast palpation capability with 1 abnormal breast
CPR
OMNI Real-time CPR feedback and reporting
Practice BVM with realistic chest rise
AIRWAY
Intubate/BVM
Tracheotomy placement
Tracheotomy intubation with resealable trachea
Trachea, bronchi, and lungs enable assessment of airway
management skills
Tongue, epiglottis, vocal cords, and esophagus look and feel real
Nasal and oral tube placement
Nasal and oral intubation
NG and OG tube feeding and gastric suction
GYN TRAINING
Bi-manual pelvic examination
Palpation of normal and pregnant uteri
Vaginal examination including insertion of speculum
Visual recognition of normal and abnormal cervices
IUD insertion and placement
Uterine sounding
Vaginal douching and Pap smear exercises with realistic vagina
and cervix
OTHER
Detachable and removable internal tanks
Bends and detaches at waist for easy storage
User Guide
Carrying bag
Neck brace
Standard
Optional
78 | Appendix
•
•
•
•
•
•
-
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
S222 & S222.250 & S222.100 | USER GUIDE
10.3 GAUMARD SALES TERMS AND CONDITIONS
These Gaumard Scientific Company, Inc. (“Gaumard”) Sales Terms and Conditions (“Terms”) apply to the sale or use of Gaumard equipment
(“Equipment”), Software (“Software” as defined in paragraph 13), and supplies (“Supplies”), collectively referred to as “Product” or “Products”
between Gaumard and the entity named on the applicable Gaumard Purchase Order (“Customer”) (collectively, “Party” or “Parties”). The Parties,
intending to be legally bound, agree as follows.
1.
Agreement. Customer agrees to purchase from Gaumard the Products set forth in quotes and purchase orders accepted by both Customer
and Gaumard from time-to-time. These Terms, along with any Exhibits, any applicable Gaumard Purchase Order documents, Gaumard Warranty
documents, Gaumard Cares Service Plan documents, and any other purchasing or service documents executed by the Parties constitute the complete
and entire agreement between Gaumard and Customer (collectively referred to herein as the “Agreement”). This Agreement will supersede all other
quotations, agreements, understandings, warranties, and representations (whether written or oral) between the Parties with respect to the subject
matter set forth in the Agreement. Any Customer documentation (including Customer’s purchase order terms and conditions) that conflicts with or
attempts to modify the Agreement in any way is hereby rejected and of no effect unless specifically agreed to in writing and signed by the Parties.
No provision of this Agreement sHAL®l be waived, amended, modified, superseded, canceled, terminated, renewed, or extended except in a written
document signed by both Parties or signed by the Party against whom the modification is sought to be enforced. This agreement can be terminated
by Gaumard without cause by giving thirty (30) days prior written notice to Customer.
2.
Prices. Prices, fees, and charges for Products and services (including maintenance, installation, and training as described in the applicable
Gaumard Purchase Order documents, Gaumard Warranty documents, Gaumard Cares Service Plan documents) (“Service” or “Services”) are payable
in United States (U.S.) Dollars only, and do not include any applicable taxes or shipping charges. If Customer claims any tax exemption, it must
furnish a valid tax exemption certificate before shipment of Products. Unless such certificate is furnished, Customer agrees to pay at its sole expense
all applicable taxes, assessments, fees, penalties, import duties, and merchandise processing fees that may be levied or assessed upon Customer or
Gaumard with respect to this Agreement, the Products, or any interest thereon. Gaumard reserves the right to increase prices on thirty (30) days
written notice to Customer.
3.
Payment. Unless otherwise agreed to in writing by Gaumard, Customer sHAL®l pay invoices net twenty (20) days from the invoice date.
A late charge will be due on any unpaid balance at a rate of 1.0% per month or the maximum rate otherwise permitted by law, whichever is lower.
Gaumard may charge interest at the maximum rate permitted by law on all amounts not paid by the invoice due date. Gaumard retains a purchase
money security interest in all Products sold to Customer to secure payment of the total purchase price thereof. Customer hereby grants Gaumard the
right to file a copy of this Agreement with any appropriate authorities to evidence this security interest. Customer agrees to execute and deliver such
other documents as Gaumard may request in connection therewith. Gaumard sHAL®l not be obligated to deliver any Product or perform any Service
during any period when Customer payment is past due. Customer will be responsible for all costs (including reasonable attorneys’ fees) incurred by
Gaumard to collect overdue payments and/or to take possession or otherwise dispose of Products for which payment is overdue.
4.
Product Shipment and Risk of Loss. Unless otherwise agreed to in writing by Gaumard, all Products will be shipped F.O.B. Origin, regardless
of any provisions for payments of freight, insurance, the form of shipping documents, or selection of carrier by Gaumard. F.O.B. Origin means title
to the Products passes to the Customer at the shipping dock of Gaumard or Gaumard’s supplier or authorized agent. Customer is responsible for
shipping charges and for the cost of insurance paid to cover any losses from Gaumard’s shipment point to Customer’s receipt. Gaumard will assist
Customer in processing any loss claims. Gaumard sHAL®l use reasonable efforts to meet the specified delivery dates. If Gaumard fails to make
delivery within a reasonable time for reasons other than Customer’s fault or circumstances beyond Gaumard’s reasonable control, then Customer’s
only remedy is the right to terminate the applicable Purchase Order, whereupon Gaumard will refund any prepayments received from Customer
relating to such Purchase Order.
5.
Installation and Acceptance. Product orders are subject to 1) written acceptance by Gaumard, 2) receipt of specified deposits, as applicable
and 3) continuing credit approval. If applicable, Gaumard will install Equipment at an agreed upon location ("Installation"). Installation sHAL®l be
complete upon Gaumard's demonstration that the Equipment meets Gaumard's then-current operating specifications ("Installation"). Installation
is subject to Customer cooperating in preparing and maintaining the site in compliance with Gaumard specifications, including but not limited to,
applicable electrical and other connection regulations and all environmental conditions. If Customer fails to accept shipment of Products other than
for breach of warranty, Customer sHAL®l immediately pay the full purchase price as if shipment and Installation had occurred. If Customer fails to
accept Products and if Gaumard decides to store ordered Products, Customer sHAL®l be responsible for Gaumard's reasonable insurance, handling,
and storage charges. If Gaumard elects not to store ordered Products, Gaumard may arrange shipment and storage in a bonded warehouse at
Customer's sole risk and expense.
6.
Delay of Performance. The Parties’ obligations under this Agreement are subject to force majeure, including but not limited to, civil
insurrection, terrorism, fire, flood, labor disputes, shortages, delays of suppliers or contractors, or government priority systems, actions taken or
threatened by any governmental agencies, acts of God or other contingencies or acts not within the sole control of the Parties. Gaumard reserves
the right during any shortage period to (a) make Supplies available to Customer (as it sees fit) without any liability to Customer, and (b) to make
substitutions and modifications in the specification of any Products, provided such substitutions or modifications do not materially affect the
performance of Products.
7.
WARRANTIES. Gaumard warrants that if a Product proves to be defective in material or workmanship within one year from the date
on which title to the Product passes to the Customer (“Warranty Period”), Gaumard will, at Gaumard's option, repair or replace the Gaumard
product. This limited warranty covers all defects in material and workmanship in the Gaumard product, except: (a) Damage resulting from accident,
misuse, abuse, neglect, or unintended use of the Gaumard product; (b) Damage resulting from failure to properly maintain the Gaumard product in
accordance with Gaumard product instructions, including failure to properly clean the Gaumard product; and (c) Damage resulting from a repair or
attempted repair of the Gaumard product by anyone other than Gaumard or a Gaumard representative. Replacement parts are warranted for the
remainder of the Warranty Period or ninety (90) days from shipment, whichever is longer. Services are warranted to be supplied in a workman-like
Appendix | 79
S222 & S222.250 & S222.100 | USER GUIDE
manner. Gaumard does not warrant that use of the Products will be uninterrupted or error-free, or that the Products will operate with non-Gaumard
authorized third-party products. THE FOREGOING WARRANTIES ARE IN LIEU OF AND EXCLUDE ALL OTHER WARRANTIES, WHETHER EXPRESS
OR IMPLIED BY OPERATION OF LAW OR OTHERWISE, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT. SUCH LIMITED WARRANTY IS GIVEN SOLELY TO THE ORIGINAL CUSTOMER
AND IS NOT GIVEN TO ANY THIRD PARTY INCLUDING, WITHOUT LIMITATION, SUBSEQUENT PURCHASERS OR USERS OF THE PRODUCTS OR
CUSTOMERS OF THE CUSTOMER. THIS WARRANTY IS VOID UPON TRANSFER OF PRODUCT BY CUSTOMER TO ANY OTHER ENTITY. SOME
STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES SO THE ABOVE EXCLUSIONS MAY NOT APPLY TO CUSTOMER. These
warranties do not apply to any Products that are supplied on a pre- release or “as-is” basis.
8.
Warranty Claims and Remedies. In the event of any warranty claim, Gaumard will replace with new or repaired items any Product part or
component that is in breach of the above limited warranties. Alternatively, Gaumard may elect to repay or credit to Customer an amount equal to the
purchase price of the defective Product. Items replaced sHAL®l become Gaumard property. All claims sHAL®l be initiated by contacting Gaumard
within the applicable Warranty Period and within thirty (30) days after discovery of the non- conformity. If Customer has failed to notify Gaumard
within the Warranty Period, then Customer sHAL®l be barred from instituting any action thereafter. Customer sHAL®l not return the Product to
Gaumard without prior authorization from Gaumard. If the necessary repairs to the Product are covered by this limited warranty, then Customer will
pay only the incidental expenses associated with the repair, including any shipping, handling, and related costs for sending the product to Gaumard
and for sending the product back to the first purchaser. However, if the repairs are not covered by this limited warranty, then Customer will be liable
for all repair costs in addition to costs of shipping and handling. Upon request, Gaumard must be given access to and an opportunity to inspect the
Product and any working areas and storage areas. These remedies sHAL®l comprise Gaumard’s entire liability and Customer’s exclusive remedy for
breach of warranty and are in lieu of any other remedies at law or equity.
9.
LIMIT OF LIABILITY. GAUMARD SHAL®L NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL, PUNITIVE, EXEMPLARY, OR CONSEQUENTIAL
LOSSES, DAMAGES, OR EXPENSES (INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS, DATA, OR USE), DIRECTLY OR INDIRECTLY ARISING
FROM THE SALE, HANDLING, SERVICE, OR USE OF PRODUCT OR SERVICES ORDERED OR FURNISHED, OR FROM ANY CAUSE RELATING
THERETO. EXCEPT FOR PERSONAL INJURY OR DEATH TO THE EXTENT RESULTING FROM GAUMARD’S NEGLIGENT OR INTENTIONALLY
WRONGFUL ACTS OR OMISSIONS, IN NO EVENT SHAL®L GAUMARD BE LIABLE UNDER ANY LEGAL THEORY OR FOR ANY CAUSE RELATED
TO A PRODUCT OR SERVICE, WHETHER BASED UPON WARRANTY, CONTRACT, TORT, NEGLIGENCE, OR OTHER THEORY, EVEN IF ADVISED OF
THE POSSIBILITY THEREOF, FOR ANY AMOUNT IN EXCESS OF THE PRICE, FEE, OR CHARGE RECEIVED BY GAUMARD FOR SUCH PRODUCT OR
SERVICE.
10.
Governmental Authorizations. Customer is responsible for compliance and costs associated with all required licenses, permits, or other
governmental authorizations, including but not limited to, any license or certification needed for Customer to use the Product, and any export or
import license, exchange permit, or the like (“Licenses”), even if applied for by Gaumard on Customer’s beHAL®f. If any authorization is delayed,
denied, revoked, restricted, or not renewed, Gaumard sHAL®l not be liable, and Customer is not relieved of its obligations. Customer represents and
agrees that it will handle all Product and technical data related to the Licenses so that it conforms to all applicable U.S. laws and regulations, including
U.S. export licensing laws and the U.S. Foreign Corrupt Practices Act. Customer sHAL®l not trans-ship, divert, re-export or otherwise dispose of any
U.S. origin goods or technology obtained from Gaumard except as U.S. laws and regulations expressly permit.
11.
Indemnity.
a.
Gaumard agrees to indemnify, defend and hold Customer, its officers, directors, employees, agents and contractors harmless from and
against all loss, damage, liability, cost and expense (including reasonable attorneys’ fees and expenses) by reason of any claims or actions by
third parties against Customer for (1) bodily injury or death, and damage, loss or destruction of any real or tangible personal property, which third
party claims arise out of or relate to Gaumard’s gross negligence or willful misconduct or (2) infringement or misappropriation by Gaumard of any
intellectual property rights under this Agreement.
b.
Customer agrees to indemnify, defend and hold Gaumard, its officers, directors, employees, agents and contractors harmless from and
against all loss, damage, liability, cost and expense (including reasonable attorneys’ fees and expenses) by reason of any claims or actions by
third parties against Gaumard for (1) bodily injury or death or damage, loss or destruction of any real or tangible personal property, which third
party claims arise out of or relate to Customer’s gross negligence or willful misconduct; (2) infringement or misappropriation by Customer of any
intellectual property rights; or
(3) Customer’s or its customer’s use of the Products or Services, including without limitation, defamation, libel, slander, obscenity, pornography, or
violation of the rights of privacy or publicity, or spamming or any other tortious or illegal conduct.
12.
Software License. For purposes of these Terms, the term “Software” includes all Gaumard computer software, firmware, and associated
documentation, whether in printed or machine-readable form, supplied by reason of this Agreement or for use in connection with Equipment or
Services. To the extent the Product includes Software, Customer’s use of the Software is governed by the Gaumard End User License Agreement
attached as Exhibit A to these Terms.
13.
Confidential Information. Customer sHAL®l maintain the confidentiality of any information provided or disclosed by Gaumard relating to
the Software (as defined above), business or customers of Gaumard, as well as this Agreement and its terms (including the pricing and other financial
terms under which the Customer will be obtaining the Services hereunder). Customer sHAL®l use reasonable care to protect the confidentiality
of Gaumard’s information disclosed, but no less than the degree of care it would use to protect its own confidential information, and sHAL®l
only disclose Gaumard’s confidential information to its employees and agents having a need to know this information and who are subject to
confidentiality agreements having terms at least as restrictive as those contained herein. The obligations of confidentiality set forth herein sHAL®l
not apply to any information in the public domain at the time of disclosure.
14.
Intended Uses. Products are only intended for the uses described in the applicable user’s manual or instructions for use. Customer
assumes all risks associated with non-listed uses of Products and hereby indemnifies and holds Gaumard harmless from any claim associated with
80 | Appendix
S222 & S222.250 & S222.100 | USER GUIDE
such non-listed uses.
15.
Compliance with Laws. Gaumard and Customer agree to comply with all federal and state laws that govern the enforceability and
performance of this Agreement.
16.
HIPAA Compliance. As of the Effective date, the Parties are not planning to transfer any personal patient information between them.
However, the Parties understand and agree that this Agreement may become subject to the Health Insurance Portability and Accountability Act of
1996 as amended (“HIPAA”), the privacy and security regulations promulgated thereunder, including 45 C.F.R. 160, 162 and 164, as amended (the
“HIPAA Regulations”), and Title XIII of Division A and Title IV of Division B (the “Health Information Technology for Economic and Clinical Health Act
(“HITECH”), part of the American Recovery and Reinvestment Act of 2009 (Pub. L. 111-5) (“ARRA”). The Parties agree to strictly comply with HIPAA
and to execute any documents that may be required by HIPAA, HITECH, and any other applicable federal or state privacy laws and regulations. The
Parties agree that if they directly or indirectly gain access to Protected Health Information (“PHI”) held by the other Party during any interaction, the
receiving Party will keep the PHI confidential under the terms of this Agreement
17.
State Reporting and Disclosure Laws. Unless otherwise noted in this Agreement, the cost of any Product training provided by Gaumard
sHAL®l be included in the purchase price of the Product where applicable. Customer acknowledges and agrees that state reporting laws may require
Gaumard to disclose certain aspects of this arrangement.
18.
Fraud and Abuse. Gaumard hereby certifies that it is not currently a listed vendor in the: (a) Federal General Services Administration’s “List
of Parties Excluded from Federal Procurement or Nonprocurement Programs” in accordance with Presidential Executive Orders 12549 and 12689
“Debarment and Suspension;” and (b) in the Office of the Inspector General of the Department of Health and Human Services’ “List of Excluded
Individuals/Entities.” Any discounted pricing terms offered under this Agreement may be a “discount or other reduction in price” under the Federal
Anti-Kickback Statute, 42 U.S.C. § 1320a-7b(b). Customer sHAL®l take all actions necessary to comply with the Anti-Kickback Statute discount safe
harbor regulations, 42 C.F.R. § 1001.952(h), including but not limited to, (1) maintaining accurate records reflecting the pricing terms of items and
Services purchased under this Agreement, (2) fully and accurately report any discount received under this Agreement if applicable, and (3) make
available information provided to Customer by Gaumard concerning cost reports and other filings with the government, including but not limited to,
the Secretary of the U.S. Department of Health and Human Services or other state agencies.
19.
Bankruptcy. Except as may be prohibited by applicable bankruptcy laws, a Party to this Agreement may elect to terminate this Agreement
(including any Purchase Orders ) if any of the following situations arise: (1) the other Party becomes insolvent or is unable to pay debts as they
become due; (2) a voluntary or involuntary bankruptcy proceeding is instituted by or against a Party hereto; or (3) an appointment of a receiver or
assignee for the benefit of creditors occurs on beHAL®f of a Party hereto.
20.
Waiver and Severability. If either Party fails to perform obligations under this Agreement, such nonperformance sHAL®l not affect the other
Party’s right to enforce performance at any time. Waiver of any remedy or material breach of any subject matter contained in this Agreement sHAL®l
not be viewed as a waiver unless agreed to by the Parties in writing. Each provision of this Agreement is separate and independent of one another,
and the unenforceability of any provision will not affect the enforceability of any other provision. If any provision is held to be excessively broad or
unenforceable, such provision sHAL®l be modified so that it is enforceable to the fullest extent possible by law.
21.
Assignment. Customer sHAL®l not assign this Agreement without the prior written consent of Gaumard, which consent sHAL®l not be
unreasonably withheld or delayed. Subject to the foregoing, the rights and obligations herein will be binding upon the successors and assigns of
Customer.
22.
Notices. Any required notices will be given in writing to Gaumard as set forth in the applicable Gaumard Purchase Order or other purchasing
document.
23.
Governing Law. Upon execution, this Agreement sHAL®l be governed and viewed under the laws of the State of Florida without reference
to its conflict of laws provisions. Customer and Gaumard specifically agree that any action relating to the relationship between the Parties, the
Agreement, or Products provided, purchased or licensed hereunder, sHAL®l be brought and tried in the Courts of Dade County, Florida. Customer
waives all objections to, and consents to the jurisdiction of such Courts.
24.
Miscellaneous. See applicable Gaumard Purchase Order documents, Gaumard Warranty documents, and Gaumard Cares Service Plan
documents for other terms and conditions, which may include, but are not limited to: Term, Termination, Customer Training and Support, and Product
Repairs and Tune Ups.
10.4 END USER LICENSE AGREEMENT
GAUMARD END USER LICENSE AGREEMENT
This End User License Agreement (“EULA”) sets forth the respective rights and responsibilities between the entity named in the Purchase Order
associated with this EULA (“End User”) and Gaumard Scientific Company, Inc., a Florida corporation (“Gaumard”), relative to the Gaumard Software
(as defined below). This EULA is effective as of the date Gaumard accepts and confirms the Purchase Order (the “Effective Date”). BY USING THE
GAUMARD SOFTWARE, END USER IS AGREEING TO BE BOUND BY THE TERMS OF THIS EULA. IF END USER DOES NOT AGREE, END USER MAY
NOT USE THE GAUMARD SOFTWARE.
1. Definitions.
1.1 “Gaumard Documentation” means the Gaumard user and operations manuals, guides, and related materials provided by Gaumard to End User to
facilitate use of the Gaumard Products.
1.2 “Gaumard Equipment” means Gaumard hardware components for medical simulation and training, including manikins and associated
instrumentation, and other hardware and tangible products sold by Gaumard to End User.
Appendix | 81
S222 & S222.250 & S222.100 | USER GUIDE
1.3 “Gaumard Products” means Gaumard Software licensed and Gaumard Equipment sold or otherwise made available by Gaumard to End User
currently or in the future.
1.4 “Gaumard Software” means the object code form of computer programs and Gaumard Documentation owned by Gaumard or its licensors and
licensed to End User in accordance with this EULA. Gaumard Software includes (a) computer programs embedded in firmware in the Gaumard
Equipment; (b) computer programs embedded in a separate medium (such as CD or flash drive) for use in conjunction with the Gaumard Equipment;
(c) computer programs downloaded or received via mail from Gaumard; (d) computer programs used on servers storing or processing data related
to the Gaumard Products; and (e) computer programs used to create and manage a network for the Gaumard Equipment, interface with the
components of the Gaumard Equipment, manage and compute location information related to the Gaumard Equipment, and monitor health of the
Gaumard Equipment.
2. Software License and Restrictions.
2.1 License. Subject to End User’s compliance with the terms and conditions of this EULA, the Gaumard Sales Terms and Conditions, the Purchase
Order, and the Gaumard Cares Service Plan Agreement, Gaumard grants End User a non-exclusive, non-transferable (except as otherwise set forth
herein), personal license to execute and use the Gaumard Software for End User’s internal purposes, but only so long as the Gaumard Software is
installed on the Gaumard Product on which it was originally installed. End User may not, directly or indirectly, sell, sublicense, display, timeshare, loan,
lease, distribute, or create derivative works of the Gaumard Software.
2.2 Ownership. All rights, title, and interest in and to the Gaumard Software, and any derivative works thereof, whether created by Gaumard, End User,
or a third party, will remain at all times solely and exclusively owned by Gaumard. Nothing in this EULA or the Purchase Order will be construed to
grant End User any rights of any kind with respect to the Gaumard Software, except as expressly set forth in this EULA.
2.3 Reverse Engineering and Other Restrictions. End User will not, and will not allow any third party to, tamper with, modify, decompile, disassemble,
derive the source code of, reverse engineer, or attempt to obtain the internal design of the Gaumard Software or Gaumard Products for any purpose
whatsoever (collectively, “Restricted Acts”). If applicable law permits End User to take any of the Restricted Acts notwithstanding the previous
prohibition, and End User wishes to take any Restricted Act notwithstanding the previous prohibition, End User will first provide Gaumard with
thirty (30) days prior written notice. Gaumard may terminate this EULA at any time during such notice period without liability arising from such
termination. The parties agree that all information needed for interoperability is available from Gaumard in accordance with applicable government
directives.
2.4Updates. From time to time Gaumard may develop new versions or updates for the Gaumard Software that may be made available to the End
User as agreed under the terms of the Gaumard Sales Terms and Conditions, Gaumard Purchase Order documents, Gaumard Warranty documents,
or Gaumard Cares Service Plan documents. Unless otherwise agreed to by Gaumard, End User sHAL®l be responsible for installing the provided new
versions or updates for the Gaumard Software.
2.5 Proprietary Notices. End User agrees to maintain and reproduce on all copies of the Gaumard Software, any names, logos, copyright notices,
trademarks, other proprietary markings, and legends that appear on the Gaumard Software.
2.6 Control of Duplication. End User will not, nor will it allow any third party to, circumvent the protection controlling the duplication or use of the
Gaumard Software, for example and without limitation, any software lock controlling the number of copies End User may make of the Gaumard
Software.
2.7 No Source Code. End User acknowledges and agrees that its rights under this EULA do not include rights to source code. In its exercise of the
rights granted under this EULA, End User agrees not to take any action that would result in any requirement to disclose or make available to other
parties the Gaumard Software in source code format.
2.8 Certification. Upon thirty (30) days written notice to End User from Gaumard, End User sHAL®l certify End User’s compliance with the restrictions
and obligations in this EULA. Such requests will not occur more frequently than once per calendar year. If End User has used the Gaumard Software
in violation of this EULA, End User sHAL®l, in addition to any other remedies Gaumard may have, pay Gaumard additional fees for the excess use
according to Gaumard’s then-current price list and policies, plus a late payment charge of one percent (1.0%) per month (or the highest amount
allowed by applicable law, if lower) for each month of excess use from the date of initial excess use.
2.9 Privacy and Recordings. End User will comply with all applicable laws, rules and regulations related to privacy, publicity and data protection
related to use of the Gaumard Products. End User sHAL®l not use the Gaumard Software to record or collect personal data from any person in
violation of End User’s policies or privacy statements. End User sHAL®l receive express consent from all persons recorded by the Gaumard Software
sufficient for End User’s use, storage, and distribution of such recordings.
3. Term and Termination
3.1 Term. This EULA commences on the Effective Date and continues perpetually, unless terminated earlier in accordance with the terms hereof.
3.2 Termination for Cause. This EULA is automatically terminated by Gaumard if the other party materially breaches this EULA, the Gaumard Sales
Terms and Conditions, the Purchase Order, or the Gaumard Cares Service Plan Agreement. In addition, Gaumard may terminate this EULA if (a) End
User becomes insolvent or makes an assignment for the benefit of End User’s creditors; or (b) a receiver is appointed or a petition in bankruptcy is
filed with respect to End User and such petition is not dismissed within thirty (30) days.
3.3 Effect of Termination. Upon the termination of this EULA for any reason, all licenses granted in Section 2 above will immediately cease and
terminate. Upon termination, End User will immediately cease using the Gaumard Software.
3.4 Survival. Sections 3 through 6 will survive the termination of this EULA.
4. Confidential Information; Trademarks.
4.1 Confidential Information. End User acknowledges and agrees that the Gaumard Software is confidential information and contains trade secrets
of Gaumard. End User agrees to (i) hold the Gaumard Software in the strictest confidence, (ii) not disclose the Gaumard Software to any third party
for any purpose, and (iii) use at least the same security measures as End User to protect its own confidential and trade secret information but no
less than reasonable measures to protect the confidentiality of the Gaumard Software. End User agrees and acknowledges that any breach of the
provisions regarding ownership or confidentiality contained in this Agreement sHAL®l cause Gaumard irreparable harm and Gaumard may obtain
injunctive relief without the requirement to post a bond as well as seek all other remedies available to Gaumard in law and in equity in the event of
breach or threatened breach of such provisions.
4.2Trademarks. End User may not use Gaumard’s trademarks, logos, service marks, or names in press releases, web sites, marketing, or other forms
of public materials without the prior written consent of Gaumard. All use of the Gaumard trademarks and all goodwill associated with them will inure
solely to the benefit of Gaumard.
5. Disclaimer; Limitation of Liability; Infringement Indemnification
5.1 Warranty and Disclaimer. For a period of twelve (12) months from the Effective Date, Gaumard will (a) provide all updates to the Software that
are made available generally, and (2) use reasonable efforts to fix or provide a workaround for any Gaumard Software defect or bug which prevents
82 | Appendix
S222 & S222.250 & S222.100 | USER GUIDE
operation in substantial conformity with the Gaumard Documentation. Other than the above, the Gaumard Software is provided “as- is,” with no
express or implied warranties of any kind, including the warranties of merchantability, fitness for a particular purpose, or non-infringement.
5.2 Limitation of Liability. THE TOTAL LIABILITY, IF ANY, OF GAUMARD TO END USER OR ANY THIRD PARTY FOR ALL DAMAGES BASED ON ALL
CLAIMS, WHETHER ARISING FROM BREACH OF CONTRACT, BREACH OF WARRANTY, NEGLIGENCE, INDEMNITY, STRICT LIABILITY, TORT, OR
OTHERWISE, ARISING FROM THE GAUMARD PRODUCTS IS LIMITED TO ONE HUNDRED DOLLARS. IN NO EVENT WILL GAUMARD BE LIABLE TO
END USER OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, CONSEQUENTIAL, OR PUNITIVE DAMAGES, INCLUDING BUT NOT LIMITED TO,
LOSS OF REVENUES, LOSS OF PROFITS, OR LOSS OF DATA, EVEN IF SUCH PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
5.3 Infringement Indemnification. Gaumard will, as further described below, indemnify, defend, and hold End User harmless, at its expense, against
any claim or suit brought by a third party against End User alleging that any Gaumard Software furnished under this EULA infringes the United States
patent, trademark, copyright or other intellectual property right of a third party. Gaumard will pay all settlements entered into or damages finally
awarded, including attorneys’ fees and costs, based on any such claim or suit; provided that End User gives Gaumard prompt written notice of such
claim and gives Gaumard information, reasonable assistance ,and sole authority to defend or settle the claim. In defense or settlement of the claim,
Gaumard may obtain for End User the right to continue using the Gaumard Software, replace or modify the Gaumard Software so that it becomes
non-infringing, or, if such remedies are not reasonably available, grant End User a refund for the associated Gaumard Products (depreciated over
three years) and accept their return. Gaumard will not have any liability if the alleged infringement is based upon (a) the use or sale of the Gaumard
Software in combination with other products or devices not furnished by or approved by Gaumard; (b) the use of the Gaumard Software in a manner
for which they were not designed as described by the Gaumard Documentation; (c) any modification of the Gaumard Software not performed by or
authorized by Gaumard;
(d) any use of Gaumard Software by End User after End User learns of such allegation of infringement; or (e) any failure by End User to utilize a
non-infringing version of the Gaumard Software made available by Gaumard along with notice that such update is non-infringing. The obligations
set forth in this Section 5.3 are Gaumard’s sole obligations, and End User’s sole and exclusive remedy, for the Gaumard Software infringing third party
intellectual property rights.
6. Miscellaneous.
6.1 Binding Effect; Assignment. This EULA will be binding upon, and inure to the benefit of, End User’s and Gaumard’s respective permitted successors
and permitted assigns. Neither party may assign or transfer this EULA or any of the rights, privileges, duties or obligations under this EULA without
the prior written consent of the other party, except that either party may assign this Agreement to any entity controlled by, controlling, or under
common control with such party at such time, as well as in connection with the sale, transfer, merger, or acquisition, whether by operation of law or
otherwise, of substantially all of the assets of such party. In addition, if End User transfers the Gaumard Product on which the Gaumard Software is
installed to a third party, End User may assign this EULA to such third party, provided that the third party agrees in writing with Gaumard to be bound
by this EULA.
6.2 Notices. Any written notice required by this EULA will be deemed made (a) when delivered by personal service, (b) one (1) business day after
being sent by recognized international overnight courier service (such as FedEx), or (c) when received, if sent by certified or registered mail, postage
prepaid, return receipt requested. Any such notice given to a party sHAL®l be sent to the addresses on the attached Purchase Order. By giving to the
other party written notice thereof, the parties hereto and their respective permitted successors and assigns will have the right from time to time to
change by written notice their respective addressee or address for notices.
6.3 Applicable Law. The validity of this EULA and the rights, obligations and relations of the parties hereunder sHAL®l be construed and determined
under and in accordance with the substantive laws of the State of Florida. All disputes arising under or related to this EULA sHAL®l be resolved
exclusively in the State or Federal Courts located in Dade County, Florida. The parties consent to the jurisdiction and venue of such courts and waive
any claims as to inconvenient forum. The judgments of such courts may be enforced in any court of competent jurisdiction.
6.4 Export Control. End User will not export or re-export the Gaumard Software, including any technical data, except as authorized and permitted
by, and in compliance with, the laws and regulations, including but not limited to all export and re-export laws and regulations, of the United States.
6.5 Severability. If any provision of this EULA is invalid or unenforceable in any circumstances, it will be interpreted as much as possible to reflect the
intent of the parties, and its application in any other circumstances and the remaining provisions of this EULA will not be affected thereby.
6.6 Entire Agreement. This EULA constitutes the entire agreement and understanding of the parties relating to the subject matter thereof. This EULA
supersedes all prior written and oral agreements and all other communications between End User and Gaumard (or a Gaumard distributor) regarding
the subject matter hereof. No contradictory terms and conditions of any purchase order, invoice, or other document issued by End User relating to
the subject matter of this EULA sHAL®l be binding, unless agreed by the parties.
6.7 Waiver of Breach. No waiver by a party of any breach of this EULA will constitute a waiver of any other breach of the same or other provisions of
this EULA. No waiver by a party will be effective unless made in a record signed or otherwise authenticated by an authorized representative of such
party.
6.8Relationship of the Parties. The parties are independent contractors. Nothing in this EULA or in the activities contemplated by the parties will be
deemed to create an agency, partnership, employment or joint venture relationship between the parties. Neither party will have any responsibility nor
liability for the actions of the other party except as expressly provided in this EULA. Neither party will have any right or authority to bind or obligate
the other party in any manner or make any representation or warranty on beHAL®f of the other party. This EULA is made and entered into for the sole
protection and benefit of Gaumard, its licensors and suppliers, and End User, and no other person or entity sHAL®l be a direct or indirect beneficiary
of or sHAL®l have any direct or indirect cause of action or claim arising from this EULA.
All rights not expressly granted in this license agreement are reserved by Gaumard.
ACKNOWLEDGMENT
By installation of this software, you acknowledge that you have read and understand the foregoing and that you agree to be bound by its terms
and conditions. You also agree that this agreement is the complete and exclusive statement of agreement between the parties and supersedes
all proposed or prior agreements, oral or written, and any other communications between the parties relating to the license described herein.
Appendix | 83
S222 & S222.250 & S222.100 | USER GUIDE
10.5 EXCLUSIVE ONE-YEAR LIMITED WARRANTY
Gaumard warrants that if the accompanying Gaumard product proves to be defective in material
or workmanship within one year from the date on which the product is shipped from Gaumard to
the customer, Gaumard will, at Gaumard’s option, repair or replace the Gaumard product.
This limited warranty covers all defects in material and workmanship in the Gaumard product, except:
» Damage resulting from accident, misuse, abuse, neglect, or unintended use of the Gaumard product;
» Damage resulting from failure to properly maintain the Gaumard product in accordance with
Gaumard product instructions, including failure to properly clean the Gaumard product;
» Damage resulting from a repair or attempted repair of the Gaumard product
by anyone other than Gaumard or a Gaumard representative.
This one-year limited warranty is the sole and exclusive warranty provided by Gaumard for the accompanying
Gaumard product, and Gaumard hereby explicitly disclaims the implied warranties of merchantability,
satisfactory quality, and fitness for a particular purpose. Except for the limited obligations specifically
set forth in this one-year limited warranty, Gaumard will not be liable for any direct, indirect, special,
incidental, or consequential damages, whether based on contract, tort, or any other legal theory regardless
of whether Gaumard has been advised of the possibilities of such damages. Some jurisdictions do not
allow disclaimers of implied warranties or the exclusion or limitation of consequential damages, so the
above disclaimers and exclusions may not apply and the first purchaser may have other legal rights.
This limited warranty applies only to the first purchaser of the product and is not transferable. Any subsequent
purchasers or users of the product acquire the product “as is” and this limited warranty does not apply.
This limited warranty applies only to the products manufactured and produced by Gaumard. This limited
warranty does not apply to any products provided along with the Gaumard product that are manufactured by
third parties. For example, third-party products such as computers (desktop, laptop, tablet, or handheld) and
monitors (standard or touch-screen) are not covered by this limited warranty. However, third-party products
are covered by the warranties provided by the respective third-party manufacturers and such warranties
are transferred from Gaumard to purchaser upon purchase of the Gaumard product. Defects in third-party
products are covered exclusively by the warranties provided by the third-parties. Gaumard does not provide
any warranty, express or implied, with respect to any third-party products. Please contact the third-party
manufacturer for information regarding the availability of extended warranties for third-party products.
Any waiver or amendment of this warranty must be in writing and signed by an officer of Gaumard.
» In the event of a perceived defect in material or workmanship of
the Gaumard product, the first purchaser must:
» Contact Gaumard and request authorization to return the Gaumard product. Do NOT return the
» Gaumard product to Gaumard without prior authorization.
» Upon receiving authorization from Gaumard, send the Gaumard product along
with copies of (1) the original bill of sale or receipt and (2) this limited warranty
document to Gaumard at 14700 SW 136 Street, Miami, FL, 33196-5691 USA.
If the necessary repairs to the Gaumard product are covered by this limited warranty, then the first
purchaser will pay only the incidental expenses associated with the repair, including any shipping,
handling, and related costs for sending the product to Gaumard and for sending the product back
to the first purchaser. However, if the repairs are not covered by this limited warranty, then the first
purchaser will be liable for all repair costs in addition to costs of shipping and handling.
Extended Warranty
In addition to the standard one year of coverage we offer a range of service plans through our Gaumard Cares
program. For more information about Gaumard Cares service planes please contact customer service.
84 | Appendix
S222 & S222.250 & S222.100 | USER GUIDE
10.6 CONTACT TECHNICAL SUPPORT
Before contacting Technical Support, please make sure to have the following:
1. Your simulator's serial number
2. Access to the simulator for possible troubleshooting as needed
Technical Support
Email:
[email protected]
USA:
800-882-6655
INT:
01-305-971-3790
10.7 GENERAL INFORMATION
Sales and Customer Service
E-mail: [email protected]
USA: 800-882-6655
INT: 01-305-971-3790
Fax: 305-252-0755
Post
Gaumard Scientific
14700 SW 136 Street
Miami, FL 33196-5691
USA
Office Hours
Monday-Friday, 8:30am - 7:30pm EST (GMT-5)
Appendix | 85
Gaumard®, ZOE®, Michelle®, Mike®, PEDI®, Susie Simon®, Susie®, Simon® Code Blue®, SIMA Models®, SIMA GYN/AID®, Virtual
Instruments®, Codemaker®, Code Blue®, NOELLE®, Simulation Made Easy™, HAL®, eCPR™, Zack™, RITA™, Chloe™, Seatbelt
Susie™, Krash Kids™, Premie™, UNI™, Omni®, Omni® 2, SmartSkin™ are trademarks of Gaumard Scientific Company.
Always dispose of this product and its components in compliance with local laws and regulations.
www.gaumard.com | 800-882-6655 | 305-971-3790 | Fax: 305-252-0755 | [email protected]
© 2022 Gaumard Scientific Company. All rights reserved. Patented; other patents pending.
MADE IN THE U.S.A.
User Guide 11.1.1 UGS---

advertisement

Key Features

  • Realistic anatomy
  • Site-specific heart & lung sounds
  • Left BP arm with palpable pulse
  • Right IV access arm
  • Gynecological training package
  • Interchangeable breast inserts
  • Tracheostomy care
  • Ulcerated foot
  • Stoma care

Frequently Answers and Questions

Can I use real needles on Super Chloe S222.100?
No, you should only use simulated needles and fluids provided by Gaumard. Using real needles can damage the simulator and invalidate your warranty.
How do I clean the IV arm after use?
Flush the venous system with a 70:30 mix of clean water to isopropyl alcohol after each use to prolong the life of the vasculature. Always drain the vein reservoirs at the end of each simulation session.
What are the interchangeable breast inserts for?
Super Chloe S222.100 comes with a set of interchangeable breast inserts that include both normal and abnormal breast tissue, allowing for practice of palpation and detection of lumps and other abnormalities.