EXTER K10m Installation Manual MAEN851B, 2014-10 English Foreword Installation manual for EXTER K10m Foreword All EXTER operator panels are developed to satisfy the demands of human-machine communication. Built-in functions such as displaying and controlling text, dynamic indication, time channels, alarm and recipe handling are included. The operator panel works primarily in an object-oriented way, making it easy to understand and use. Configuration is carried out on a PC using the configuration tool. The project can then be transferred and stored in the operator panel itself. Various types of automation equipment such PLCs, servos or drives can be connected to the EXTER operator panels. In this manual, the term “the controller” refers to the connected equipment. This manual explains how to install the operator panel. Please refer to the reference manual for further information. Order no: MAEN851B Copyright © 2014-10 Beijer Electronics AB. All rights reserved. The information in this document is subject to change without notice and is provided as available at the time of printing. Beijer Electronics AB reserves the right to change any information without updating this publication. Beijer Electronics AB assumes no responsibility for any errors that may appear in this document. Read the entire installation manual prior to installing and using this equipment. Only qualified personnel may install, operate or repair this equipment. Beijer Electronics AB is not responsible for modified, altered or renovated equipment. Because the equipment has a wide range of applications, users must acquire the appropriate knowledge to use the equipment properly in their specific applications. Persons responsible for the application and the equipment must themselves ensure that each application is in compliance with all relevant requirements, standards and legislation in respect to configuration and safety. Only parts and accessories manufactured according to specifications set by Beijer Electronics AB may be used. BEIJER ELECTRONICS AB SHALL NOT BE LIABLE TO ANYONE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE INSTALLATION, USE OR REPAIR OF THIS EQUIPMENT, WHETHER ARISING IN TORT, CONTRACT, OR OTHERWISE. BUYER'S SOLE REMEDY SHALL BE THE REPAIR, REPLACEMENT, OR REFUND OF PURCHASE PRICE, AND THE CHOICE OF THE APPLICABLE REMEDY SHALL BE AT THE SOLE DISCRETION OF BEIJER ELECTRONICS AB . Beijer Electronics, MAEN851B Contents Contents 1 Safety Precautions ....................................................... 1.1 General ........................................................... 1.2 UL and cUL Installation ......................................... 1.3 During Installation .............................................. 1.4 During Use ....................................................... 1.5 Service and Maintenance ........................................ 1.6 Dismantling and Scrapping ..................................... 2 Installation ............................................................... 2.1 Space Requirements ............................................. 2.2 Installation Process .............................................. 2.2.1 2.2.2 2.2.3 Mode Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Connections to the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Other Connections and Peripherals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 3 Technical Data ........................................................... 4 Chemical Resistance .................................................... 4.1 Metal Casing ..................................................... 4.2 Screen and Overlay Material .................................... 4.2.1 4.2.2 4.2.3 4 4 4 6 6 6 6 7 7 7 11 12 12 12 Autotex F157/207 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Screen Surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Screen and Keyboard Protector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 5 Operator Panel Drawings .............................................. 5.1 Communication Ports ........................................... 5.2 EXTER K10m Outline .......................................... 5.3 EXTER K10m Text Strip ........................................ 6 Additional Installation Tips ............................................ 6.1 Grounding the Operator Panel ................................. 6.2 Ethernet Connection in the Panel .............................. 6.3 To Achieve Better EMC Protection ............................. 6.4 Ambient Temperature ........................................... 6.5 Safety ............................................................. 6.6 Galvanic Isolation ................................................ 6.7 Cable and Bus Termination RS485 ............................. Beijer Electronics, MAEN851B 15 15 16 17 18 18 19 20 21 22 23 24 Safety Precautions 1 Safety Precautions Both the installer and the owner and/or operator of the operator panel must read and understand this installation manual. 1.1 • • • • • • • • • • • • General Read the safety precautions carefully. Check the delivery for transportation damage. If damage is found, notify the supplier as soon as possible. The supplier is not responsible for modified, altered or reconstructed equipment. Use only parts and accessories manufactured according to specifications of the supplier. Read the installation and operating instructions carefully before installing, using or repairing the operator panel. Never allow fluids, metal filings or wiring debris to enter any openings in the operator panel. This may cause fire or electrical shock. Only qualified personnel may operate the operator panel. Storing the operator panel where the temperature is lower/higher than recommended in this manual can cause the LCD display liquid to congeal/become isotopic. The LCD display liquid contains a powerful irritant. In case of skin contact, wash immediately with plenty of water. In case of eye contact, hold the eye open, flush with plenty of water and get medical attention. The figures in this manual serves an illustrative purpose. Because of the many variables associated with any particular installation, the supplier cannot assume responsibility for actual use based on the figures. The supplier neither guarantees that the operator panel is suitable for your particular application, nor assumes responsibility for your product design, installation or operation. It is recommended to turn on and shut down the operator panel at least once before installing any components/cards or before connecting the operator panel to external devices, like for example serial devices. 1.2 UL and cUL Installation Caution: This section is only valid for UL labeled EXTER K10m panels. • • This equipment is suitable for use in non-hazardous locations only. [Combinations of equipment in your system are subject to investigation by the local authority having jurisdiction at the time of installation]. All devices have to be supplied by a Class 2 power supply. Beijer Electronics, MAEN851B 4 Safety Precautions Warning: Do not disconnect equipment unless power has been removed or the area is known to be non-hazardous AVANT DE DECONNECTER L’EQUIPEMENT, COUPER LE COURANT OUS’ASSURER QUE L‘EMPLACEMENT EST DESIGNE NON DANGEREUX. Warning: Only UL and cUL approved expansion units are allowed to be connected to the port designated “EXPANSION”. At the moment there are no such units evaluated or allowed. SEULES LES UNITÉS D'EXTENSION CERTIFIÉES UL ET cUL PEUVENT ÊTRE RACCORDÉES AU PORT DÉSIGNÉ « EXPANSION ». À L'HEURE ACTUELLE, AUCUNE UNITÉ DE CE TYPE N'A ÉTÉ TESTÉE OU AUTORISÉE. Warning: Do not replace expansion unit unless power has been switched off or the area is known to be non-hazardous. NE REMPLACEZ L'UNITÉ D'EXTENSION QUE SI LE COURANT A ÉTÉ COUPÉ OU SI LA ZONE EST JUGÉE NON DANGEREUSE. • • This product contains a rechargeable battery; this must only be changed in an area known to be non-hazardous. Replace the battery with a MS614S battery. Use of another type of battery may present a risk of fire or explosion. Warning: Battery may explode if mistreated. Do not recharge, disassemble or dispose of in fire. LA BATTERIE PEUT EXPLOSER EN CAS DE MAUVAISE MANIPULATION. NE LA RECHARGEZ PAS, NE LA DÉMONTEZ PAS ET NE LA JETEZ PAS DANS LE FEU. • • • • For use on a flat surface of a type 4X enclosure indoor use only. Use minimum 75°C copper conductors only. To make wiring connections to the power supply connector, follow the table with cable and torque specifications below: Terminal Block Connector Wire Size TQ Lb.In. X1/X100 Phoenix connectors AWG 30–12 5–7 X1/X100 Anytek connectors AWG 24–12 3.5 These devices are Class 2 supplied programmable controllers (industrial PCs) for the use in industrial control equipment and are intended to be (front) panel mounted (Type 1 and 4x for indoor use only). Beijer Electronics, MAEN851B 5 Safety Precautions Caution: The enclosure provides a degree of protection of at least IP20, but when installed in an apparatus, it should meet IP54. LE BOÎTIER OFFRE UN DEGRÉ DE PROTECTION D'AU MOINS IP20, MAIS LORSQU'IL EST INSTALLÉ DANS UN APPAREIL, IL DOIT ÊTRE DE CLASSE IP54. 1.3 During Installation • The operator panel is designed for stationary installation on a plane surface, where the following conditions are fulfilled: – no high explosive risks – no strong magnetic fields – no direct sunlight – no large, sudden temperature changes • • • • • Install the product according to the accompanying installation instructions. Ground the product according to the accompanying installation instructions. Only qualified personnel may install the operator panel. Separate the high voltage, signal and supply cables. Make sure that the voltage and polarity of the power source is correct before connecting the product to the power outlet. Peripheral equipment must be appropriate for the application and location. • 1.4 • • • Keep the operator panel clean. Emergency stop and other safety functions may not be controlled from the operator panel. Do not use excessive force or sharp objects 1.5 • • • • • • Service and Maintenance Only qualified personnel should carry out repairs. The agreed warranty applies. Before carrying out any cleaning or maintenance operations, disconnect the equipment from the electrical supply. Clean the display and surrounding front cover with a soft cloth and mild detergent. Replacing the battery incorrectly may result in explosion. Only use batteries recommended by the supplier. During the warranty period, the battery needs to be replaced by an authorized Beijer Electronics service center. 1.6 • During Use Dismantling and Scrapping The operator panel or parts thereof shall be recycled according to local regulations. The following components contain substances that might be hazardous to health and the environment: lithium battery, electrolytic capacitor and display. Beijer Electronics, MAEN851B 6 Installation 2 Installation 2.1 Space Requirements • • Installation plate thickness: 1.5 - 7.5 mm (0.06 - 0.3 inch) Space requirements when installing the operator panel: 100 mm (4.0 inch) 114 mm (4.49 inch) 50 mm (2.0 inch) 50 mm (2.0 inch) 100 mm (4.0 inch) 100 mm (4.0 inch) 46.4 mm (1.83 inch) 155 mm (6.10 inch) Caution: The openings on the enclosure are for air convection. Do not cover these openings. 2.2 Installation Process 1. Unpack and check the delivery. If damage is found, notify the supplier. Panel cut out 121 x 80 mm (4.76 x 3.15 inch) x4 Note: Place the operator panel on a stable surface during installation. Dropping it or letting it fall may cause damage. Beijer Electronics, MAEN851B 7 Installation 2. Place the panel cut out where the operator panel is to be situated, draw along the outer sides of the holes and cut according to the markings. For text strip 12.0 mm (0.48 inch) 8.0 mm (0.31 inch) 3. Secure the operator panel in position, using all the fastening holes and the provided brackets and screws: x4 0.5 - 1.0 Nm Beijer Electronics, MAEN851B 8 Installation 4. Connect the cables in the specified order, according to the drawing and steps below. Caution: • The operator panel must be brought to ambient temperature before it is started up. If condensation forms, ensure that the operator panel is dry before connecting it to the power outlet. • Ensure that the operator panel and the controller system have the same electrical grounding (reference voltage level), otherwise errors in communication may occur. • Ensure that the voltage and polarity of the power source is correct. • Separate high voltage cables from signal and supply cables. • Shielded communication cables are recommended. Power B Controller 24V DC RS422/ RS485 RS232 24V DC C D A Connect cable A. Connect cable B, using an M5 screw and a grounding conductor (as short as possible), that is sized correctly according to local electrical codes. – Connect cable C. – Connect cable D. 5. Carefully remove the laminated film over the operator panel display, to avoid static electricity that could damage the panel. – – Beijer Electronics, MAEN851B 9 Installation 2.2.1 Mode Switches All mode switches must be in OFF position during operator panel use. The mode switches should not be touched unless by qualified personnel. ON DIP 1 2 3 4 2.2.2 Connections to the Controller For information about the cables to be used when connecting the operator panel to the controller, please refer to the help file for the driver in question. 2.2.3 Other Connections and Peripherals Cables, peripheral equipment and accessories must be suitable for the application and its environment. For further details or recommendations, please refer to the supplier. Beijer Electronics, MAEN851B 10 Technical Data 3 Technical Data Parameter EXTER K10m Front panel, W x H x D 155 x 114 x 6 mm Mounting depth 46.4 mm Front panel seal IP 66 Rear panel seal IP 20 Keyboard material Membrane switch keyboard with metal domes. Overlay film of Autotex F207* with print on reverse side. 1 million operations. Reverse side material Powder-coated aluminum Weight 0.45 kg Serial port RS422/RS485 25-pin D-sub contact, chassis-mounted female with standard locking screws 4-40 UNC Serial port RS232C 9-pin D-sub contact, male with standard locking screws 4-40 UNC Flash memory for application 512 kB Real time clock ±20 PPM + error because of ambient temperature. Total maximum error: 1 minute/month at 25 °C. Temperature coefficient: -0.034±0.006 ppm/°C2 Real time clock battery (rechargeable) MS614S (UL and cUL: SII Micro Parts Ltd) Power consumption at rated voltage Normal: 0.1 A Maximum: 0.3 A Display FSTN-LCD, 160 x 32 pixels, monochrome transmissive negative. LED backlight lifetime at the ambient temperature of +25 °C: >47,000 h. Active area of display, W x H 89.6 x 17.9 mm Fuse Internal DC fuse, 1.0 AT, 5 x 20 mm Power supply +24 V DC (20 - 30 V DC). Power supply connector. CE: The power supply must conform with the requirements according to IEC 60950 and IEC 61558-2-4. UL and cUL: The power supply must conform with the requirements for class II power supplies. Ambient temperature Vertical installation: 0 ° to +50 °C Horizontal installation: 0 ° to +40 °C Storage temperature -20 ° to +70 °C Relative humidity 5 - 85 % non-condensed Approvals and certifications Information is available on the web site www.beijerelectronics.com * See section Chemical Resistance for more information. Beijer Electronics, MAEN851B 11 Chemical Resistance 4 Chemical Resistance 4.1 Metal Casing The frame and casing material is powder-coated aluminum. This powder paint withstands exposure to the following chemicals without visible change: Acetic acid 10% Phosphoric acid 4% Citric acid 10% Phosphoric acid 10% Diesel Sea water Distilled water Sodium chloride 2% Edible oil Sodium chloride 20% Fuel oil Sulphuric acid 20% Hydrogen peroxide 3% Tap water The powder paint shows limited resistance to the following chemicals at room temperature: Butanol Nitric acid 3% Hydrochloric acid 5% Nitric acid 10% Isopropyl alcohol Phosphoric acid 43% Na-hypochlorite 10% Turpentine Note: If exposure to any of the above chemicals is demanded, it is recommended to first test the chemical in a hidden spot of the metal casing. The powder paint shows little or no resistance to the following chemicals at room temperature: Acetic acid, conc. Methyl-ethyl ketone Toluene Acetone Nitric acid 30% Trichlorethylene Ammonia 5% Phenol Xylene Ammonia, conc. Sodium hydroxide 5% 97 octan unleaded petrol Ethyl acetate Sodium hydroxide 30% 98 octan leaded petrol 4.2 4.2.1 Screen and Overlay Material Autotex F157/207 Autotex F157 or F207 covers the overlay surrounding the screen. Beijer Electronics, MAEN851B 12 Chemical Resistance Solvent Resistance Autotex F157/F207 withstands exposure of more than 24 hours duration under DIN 42 115 Part 2 to the following chemicals without visible change: Acetonitrile Diesel Downey / Lenor1 Phosphoric acid (<30%) Ajax / Vim in solution Ethanol Potassium ferricyanide Alkalicarbonate solution1 Glycerine Potassium hydroxide (<30%) Ammonia (<40%)1 Glycol Pure Turpentine Acetic acid (<50%) Gumption1 SBP 60/951 Ariel powder in solution1 Hydrochloric acid (<36%) Sulfuric acid (<10%) Bleach1 Linseed oil Tomato ketchup Castor oil Methanol Trichloroacetic acid (<50%) Caustic soda (<40%)1 Nitric acid (<10%) White Spirit Cutting oil Paraffin oil Windex1 Cyclohexanol Persil powder in solution1 Wisk Diacetone alcohol Petroleum spirit1 - 1 Extremely faint glossing of the texture was noted. Autotex withstands DIN 42 115 Part 2 exposure of up to 1 hour duration to glacial acetic acid without visible change. Autotex is not resistant to high pressure steam at over 100 °C or the following chemicals: Concentrated mineral acids Benzyl alcohol Concentrated caustic solution Methylene chloride Outdoor Use In common with all polyester based films Autotex F157/F207 is not suitable for use in conditions of long term exposure to direct sunlight. 4.2.2 Screen Surface The screen surface on the operator panel withstands exposure to the following solvents without visible change: Solvents Time Acetone 10 minutes Isopropanol 10 minutes Toluene 5 hours Beijer Electronics, MAEN851B 13 Chemical Resistance 4.2.3 Screen and Keyboard Protector For harsh environments and exposure to outdoor conditions, it is recommended to use a protective film to guard the screen and the keyboard from damage. These optional parts can be ordered from Beijer Electronics. Beijer Electronics, MAEN851B 14 Operator Panel Drawings 5 Operator Panel Drawings 5.1 Communication Ports RS-232 RS-422 RS-485 RS-422/485 Beijer Electronics, MAEN851B 15 Operator Panel Drawings 5.2 EXTER K10m Outline Beijer Electronics, MAEN851B 16 Operator Panel Drawings 5.3 EXTER K10m Text Strip (unit: mm) 9.0 4.5 11.25 19.0 20.5 20.5 138.0 20.5 19.0 Text max 18.5x7.5 Text max 15.5x7.5 R1 (4x) Beijer Electronics, MAEN851B 17 Additional Installation Tips 6 Additional Installation Tips When experiencing communication problems in for example noisy environments or when operating close to temperature limits, the following recommendations are to be noticed. 6.1 Grounding the Operator Panel Mounting plate in the cabinet Door Operator panel 3 2 Power supply 1 Ferrite core 24 V DC 5 6 4 5350 The operator panel’s mounting clamps do not provide a secure grounding connection between the panel and the device cabinet, see 1 in drawing above. 1. Connect a wire that is sized correctly according to local electrical codes between the operator panel’s quick-connect plinth and the panel’s chassis, see 2 in drawing above. 2. Connect a 6 or 4 mm2 wire or grounding braid between the panel’s chassis and the closest grounding point on the door, see 3 in drawing above. 3. Connect a strong but short grounding braid between the door and the device cabinet, see 4 in drawing above. 4. Twist the cables onto the 24 V DC feed, see 5 in drawing above. 2 turns around the ferrite core provide 4 times the suppression of 1 turn. 3 turns around the ferrite core provide 9 times the suppression of 1 turn. A ferrite core suppresses disturbances to the 24 V feed, see 6 in drawing above. Note: The grounding wires should be short and the conductor should have a large area. A long, thin grounding wire has a very high impedance (resistance) at high frequencies and will not guide disturbances to the ground. Multi-wire conductors are better than single wire conductors with the same area. A braided conductor wire with the same area is even better. The best is a short, thick grounding braid. Beijer Electronics, MAEN851B 18 Additional Installation Tips 6.2 Ethernet Connection in the Panel Industrial Ethernet RJ45 RJ45 1 RJ45 RJ45 Operator panel RJ45 3 2 Operator panel RJ45 4 Shielded 1-1 2-2 3-3 Short and unshielded Operator panel RJ45 8-8 5 Operator panel RJ45 0.1 uF 250 V 5351 In some industrial units for Ethernet, the RJ45 contact’s shield is connected to the chassis via a capacitor, see 1 in drawing above. The operator panel’s Ethernet shield is directly connected to the chassis, see 2 in drawing above. 1. Check whether the other Ethernet unit has its shield directly grounded or grounded via a capacitor. Note: In many cases, connecting the shielded Ethernet cabling to the chassis at both ends is inappropriate. Hum or grounding loops can occur. Unshielded cabling may even result in fewer communication errors. A good solution may be to use a shielded Ethernet cable, but to connect the shield at one end only. One option is to break the shield, see 3 in drawing above. A more elegant method is to expand the shielded Ethernet cabling with a piece of unshielded Ethernet cable, see 4 in drawing above. You can ground the shield via an external 0.1 µF/250 V plastic capacitor, see 5 in drawing above. This will connect the HF transients to the ground. Beijer Electronics, MAEN851B 19 Additional Installation Tips 6.3 • • • • • • • To Achieve Better EMC Protection Use shielded cables for RS232 communication. Use twisted pair and shielded cabling for RS422 and RS485. Use the cabling intended for the bus type; Ethernet, Profibus, CC-Link, CAN, Device Net etc. Install and connect according to applicable specifications for the relevant bus standard. Use shielded cabling for Ethernet, preferably with foil and a braided shield. D-sub covers should be shielded, and the shield should be connected to the cover 360° where the cable enters. Connect the shield at both ends. Shielded cable 0.1 uF/250 V Ground plane 1 Ground plane 2 Not same potential 5352 Ground plate Ground plate in another building With longer distances, there is a risk that the ground potential may be different. In that case, the shield should only be connected at one end. A good alternative is to connect the other end of the shield to the ground via a 0.1 µF/250 V plastic capacitor. Both ends are then connected to the ground in terms of HF, but only connected to the ground at one end in terms of LF, thus avoiding the 50 Hz grounding loops. Metal cabinet Metal cabinet Terminal or connector Short distance Terminal or connector EMC cable gland Shielded cable Cable clamp in steel Plastic cable gland Shielded cable 5353 1. Use an EMC cable gland or regular plastic cable gland, remove the outer jacket and connect the shield to the installation plate with a 360 ° metal cable clamp. 2. Place the 24 V DC and communications cabling in one cable trunk/cable duct and 230/380 V AC in another. If the cables need to be crossed, cross them at 90 ° only. Avoid combining the cabling for stronger 24 V DC outputs with the communication cabling. Ferrite cores that are snapped onto the shielded cabling may remove minor disturbances. Large ferrite pieces that are snapped onto unshielded cabling and where the wires go 2-4 times around the cores are approximately 5-25 times more efficient. Beijer Electronics, MAEN851B 20 Additional Installation Tips 6.4 Ambient Temperature The maximum ambient temperature for the operator panel is provided in the specifications. The ambient temperature refers to the temperature in the device cabinet which cools the panel’s electronics. Top 50 °C inside Operator panel Power Power 30 °C outside Axial fan 120 x 120 mm Middle 45 °C inside Airflow Power Bottom 40 °C inside 5354 In most cases, the ambient temperature for the operator panel is significantly higher than the device cabinet’s ambient temperature. If the cabinet is tall and there are a number of heat-generating devices, the temperature at the top of the cabinet will be considerably higher than the theoretical temperature increase that would be expected. All electronics are sensitive to heat. The lifespan of an electrolytic capacitor is cut in half with an 8-10 °C increase in temperature. A 15-20 °C temperature increase results in a quarter of the lifespan etc. Rittal has a good program for estimating the anticipated average temperature in the cabinet as well as a large program for controlling the temperature in the device cabinet. An enamel-coated steel cabinet has a radiant heat value of 5.5 W/m2 and degrees C. Installing a fan inside the cabinet will even out the temperature, while moving air provides considerably better cooling than still air. A suitable fan is a 120 x 120 mm axial fan, available in 24 V DC, 115 and 230 V AC. Install the fan so that it sits in the cooler area and blows cold air against the operator panel. If the fan is mounted at the top and sucks warm air upwards, the fan’s ambient temperature will be higher, resulting in a shorter lifespan. A good fan with a ball-bearing mounting has an expected lifespan of at least 40,000 hours (not a guaranteed lifespan) at 40 °C. This corresponds to at least 4 years of continuous use. If a thermostat is installed, the fan only operates when needed. Large graphic terminals draw only one fifth of the current when the background lighting is off. The loss effect drops from e.g. 25 W to only 5 W. An approximate value of the net power consumption for the operator panel can be calculated by multiplying the supply voltage with the current drawn by the operator panel. This is assuming that all supplied power is transformed to heat. Beijer Electronics, MAEN851B 21 Additional Installation Tips 6.5 Safety Most of the operator panels are fed with 24 V DC. Power supply 230 V AC to 24 V DC Operator panel +24 V 1 0V 4 Power supply 230 V AC to 24 V DC Operator panel +24 V 2 0V 4 Distance? Power supply 230 V AC to 24 V DC Operator panel +24 V 3 0V 4 COM1 Small controller with expansion unit Ch0 Ch1 230 V AC COM100 Ch100 Ch101 5355 If a power supply that meets safety standards is used and only feeds the operator panel, there is no problem. See 1 in drawing above. However, if a 24 V unit that also feeds other units is used, there is reason to be cautious, see 2 in drawing above. The operator panel does not have insulation that meets safety requirements in the event of a potential short circuit between 230 V AC and 24 V DC. It is assumed that the 24 V feed is secure, for example, SELV according to EN 60950 (protection against electric shock) and UL 950. Note: Here is an example that explains why a secure 24 V DC feed can be ruined by mixing 24 V relay contacts with 230 V AC relay contacts in a smaller controller. Check that the clearances and creepage distances between 24 V DC and 230 V AC fulfill EN 60950 or UL 950. If not, input a separate 24 V unit into the operator panel. If there is a substantial distance between the relay contacts for 24 V DC and 230 V AC, it is OK to use the same 24 V devices for all feeds. See 3 in drawing above. Connect 0 V on the 24 V feed to the ground, see 4 in drawing above. This offers three advantages: • Safety is increased. The 24 V feed will not be live in the event of a faulty connection or short circuit between 0 V (24 V) and 230 V phase. • Transients on the 24 V feed are connected to the ground. • No risk that the 24 V feed is at a high level in relationship to the ground. This is not unusual since there is high static electricity. Beijer Electronics, MAEN851B 22 Additional Installation Tips 6.6 Galvanic Isolation Internal electronic Filter Ethernet DC/DC galvanic isolation DC/AC VCC +24 V DC CFL 0 V (GND) 0V 1.5 m RS422/485 RS232 USB 5356 USB The operator panel has galvanic isolation against the 24 V DC feed but no galvanic isolation between the communication ports for RS232, RS422/485 and USB. Only the Ethernet connection has galvanic isolation. Operator panel Modular controller Power CPU RS422 * RS232 * * * * USB * PC * Not same ground potential * = Internal 0 V (GND) connection Printer COM COM2 * PC * 5357 When a PC is connected to the panel, the panel’s internal 0 V (GND) will be connected to the protective ground via the PC. A number of USB devices can have the shield connected together with the protective ground. Here, the panel’s 0 V (GND) is connected to the protective ground when, for example, a USB memory stick, keyboard or similar device is plugged in. If a number of units are connected that have a 0 V and a ground connection, and these are connected to various grounding points, there is a substantial risk of problems. Grounding currents go through communication cables, the rear plate of the controller, and internally in the operator panel, and can cause errors. Use external units to improve communication and achieve galvanic isolation. Westermo has good industry-standard insulators that are also insulated from the 24 V DC feed. Note: It is very important to make sure that the 24 V feed in the external insulation unit is not connected to one of the communication outlets. If it does not have 100% insulation against the 24 V feed, disturbances and grounding currents from the 0 V on the 24 V side will disrupt communication. Using this type of unit solves one problem but creates a larger problem! A substandard installation may work now, but problems may arise when other devices are connected. Beijer Electronics, MAEN851B 23 Additional Installation Tips 6.7 • Cable and Bus Termination RS485 Use shielded and twisted pair cable. The pair capacitance may not exceed 52.5 pF/m and area at least 0.25 mm2 (AWG 24), if you want to use the maximum transfer distance and maximum transfer speed. 0 V, the reference voltage for communication should be included in the cabling. With two-way communication use two pairs; one pair for communication and one pair for 0 V. The shield must be grounded at one end. The other end is usually grounded, but with longer distances or when there is a difference in the ground potential, the shield should be connected to the ground via 0.1 μF/250 V plastic capacitor to prevent ground current in the braided shield. A number of manufacturers recommend that the shield be grounded at each node. Various manufacturers have different systems for bus termination. The RS485 standard does not describe how the “Fail Safe” function would be carried out, just that the system should be able to handle the error. • • Depending on the recipients’ design, the bus wires may be on the same level or require pull-up or pull-down to ensure that no faulty signals are detected when the bus is in resting mode (all transmitters are disconnected). Inside operator panel +5 V 1 +5 V 2 14 3 1K 1K 120 ohm 2 15 120 ohm 6 19 (120 ohm) 1K 0V 1K 7 8 4 CAB8 Operator panel RS422 55 1 2 3 4 5 6 7 8 17 50 +5 V 0V 0V 0V 0V CAB8 Bus RS485 2 15 1 2 3 16 3 4 17 4 5 6 14 8 7 VCC VCC 1K 120 ohm 1K 0V 0V Shield 7 8 Bus termination 5358 Some (older) operator panels had pull-up and pull-down resistance except for the actual bus termination at 120 Ω, similar to Westermo and Profibus. See 1 in drawing above. Newer panels have another type of recipient, so-called built-in “Fail Safe”, where simple bus termination resistance is sufficient. See 2 in drawing above. If other nodes on the RS485 network require pull-up and pull-down and the operator panel is at one end of the loop, one of the following procedures can be carried out: • Connect two 1 kΩ / 0.25 W resistors in the 25-pole D-sub contact. See 3 in drawing above. Set jumper pins 6-19. • Use CAB8. It offers the option of bus termination with pull-up/-down. It is also easy to connect the bus cable via the screw terminal block. See 4 in drawing above. Beijer Electronics, MAEN851B 24 Head office Beijer Electronics AB Box 426 201 24 Malmö, Sweden www.beijerelectronics.com / +46 40 358600
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement