OHAUS Frontier FC5706 Service Manual
Ohaus Frontier FC5706 is a versatile centrifuge designed for various laboratory applications. It boasts user-friendly controls, a digital display, and various safety features, ensuring accurate and reliable operation. You can adjust different parameters like speed, time, and acceleration/deceleration rates to suit your specific requirements. The centrifuge also features rotor recognition, imbalance detection, and lid lock mechanisms for safety. It is suitable for various applications such as blood separation, cell culture, and biochemical analysis.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
SERVICE MANUAL FC5706 CENTRIFUGE Ohaus Corporation 7 Campus Drive, Suite 310, Parsippany, NJ 07054, USA +1 973 377 9000 TABLE OF CONTENTS Page No. CHAPTER 1 GETTING STARTED 1.1 1.2 1.3 Introduction ..............................................................................................................1-1 Definition of Signal Warning and Symbol .................................................................1-1 Safety Precaution .....................................................................................................1-2 1.3.1 User ................................................................................................................1-2 1.3.2 Rotor and Accessories ....................................................................................1-2 1.3.3 Measures of your protection ............................................................................1-2 1.3.4 Exclude the Following environment Influence ..................................................1-3 1.3.5 Measures for Operation Safety ........................................................................1-3 1.3.6 Danger & Precaution ...................................................................................... 1-3 1.4 Service Facilities ......................................................................................................1-4 1.5 Tools and Test Equipment's Required......................................................................1-4 1.5.1 Tools and Test Equipment's Required .............................................................1-4 1.6 Transport and packing of FC5706 ............................................................................1-5 1.6.1 Transport.........................................................................................................1-5 1.6.2 Packing ...........................................................................................................1-5 1.7 Technical Data .........................................................................................................1-5 1.7.1 Acceleration and Deceleration Times FC5706.................................................1-5 1.7.2 Imbalance Shut Off Data FC5706....................................................................1-5 1.7.3 Specifications ..................................................................................................1-6 1.8 Service Instructions ..................................................................................................1-7 1.8.1 General Technical Descriptions .......................................................................1-7 1.8.2 Electrical and Electronic Components .............................................................1-9 1.8.2.1 Control Board .......................................................................................1-9 1.8.2.2 Rotor Recognition ...............................................................................1-10 1.8.2.3 Speed Signal ......................................................................................1-10 1.8.2.4 Lid Mechanism ...................................................................................1-10 1.8.2.5 Imbalance Detection ...........................................................................1-11 1.9 LCD Display ...........................................................................................................1-12 1.10 Function Label .......................................................................................................1-13 CHAPTER 2 SERVICE MENU 2.1 2.2 Service Menu ...........................................................................................................2-1 2.1.1 Activation of the Service Menu (Part 1) ...........................................................2-1 2.1.2 Submenu Motor Start ......................................................................................2-2 2.1.3 Submenu Duty Cycle.......................................................................................2-2 2.1.4 Submenu Running Time ..................................................................................2-3 2.1.5 Submenu Software Status ...............................................................................2-3 2.1.6 Submenu Error Memory ..................................................................................2-4 2.1.7 Submenu Keyboard Test .................................................................................2-5 2.1.8 Submenu Activation/Deactivation of the Imbalance Sensor .............................2-5 Activation of the Service Menu (Part 2) ....................................................................2-6 2.2.1 Centrifuge Model .............................................................................................2-7 2.2.2 Submenu Adjustment/Correction of the Imbalance Cut Off Value....................2-7 Ohaus Corporation www.ohaus.com i FC5706 Centrifuge Service Manual TABLE OF CONTENTS CHAPTER 3 MAINTENANCE PROCEDURES 3.1 3.2 3.3 3.4 3.5 3.6 Page No Preventive Maintenance ...........................................................................................3-1 3.1.1 General ...........................................................................................................3-1 3.1.2 Cleaning and Disinfection of the Unit ...............................................................3-2 3.1.3 Cleaning and Disinfection of the Rotor ............................................................3-2 3.1.4 Disinfection of Aluminum Rotor .......................................................................3-3 3.1.5 Disinfection of PP-Rotor ..................................................................................3-3 3.1.6 Glass Breakage...............................................................................................3-4 Service Life of Rotors, Round and Rectangular Buckets, Accessories .....................3-4 Mounting Support .....................................................................................................3-5 3.3.1 Replacing the Front Housing ...........................................................................3-5 3.3.2 Replacing the Incremental Shaft encoder (Potentiometer)...............................3-5 3.3.3 Replacing the Display......................................................................................3-6 3.3.4 Replacing the Foil Key Board ..........................................................................3-7 3.3.5 Removing the Housing ....................................................................................3-7 3.3.6 Replacing the Rotor Chamber or Lid Gasket ...................................................3-8 3.3.7 Removing the Lid ............................................................................................3-9 3.3.8 Replacing the Hinges ......................................................................................3-9 3.3.9 Replacing the Motor ......................................................................................3-10 3.3.10 Replacing the Power Board/Control Board ..................................................3-11 3.3.11 Checkup the Imbalance Sensor...................................................................3-11 3.3.12 Replacing the Imbalance (movement sensor) and Speed Sensor ...............3-12 3.3.13 Replacing the Lid Lock ................................................................................3-12 3.3.14 Adjustment of the Lid ...................................................................................3-13 Major internal cable connection ..............................................................................3-14 Trouble Shooting ....................................................................................................3-16 3.5.1 Error Message: Cause/Solution .....................................................................3-16 3.5.2 Possible Error Message and Their Solutions .................................................3-16 3.5.2.1 Lid Release during Power Failure .......................................................3-16 3.5.2.2 Descriptions of the Error Message.......................................................3-17 Error Codes............................................................................................................3-18 FC5706 Centrifuge Service Manual ii Ohaus Corporation www.ohaus.com CHAPTER 1 GETTING STARTED 1.1 INTRODUCTION This service manual contains the information needed to perform routine maintenance and service on the Ohaus centrifuge model FC5706. Before servicing the equipment, you should be familiar with the Instruction Manual which is packed with every equipment. 1.2 DEFINITION of SIGNAL WARNING AND SYMBOLS. Safety notes are marked with signal words and warning symbols. These show safety issues and warnings. Ignoring the safety notes may lead to personal injury, damage to the instrument, malfunctions and false results. The degree of danger is a part of a safety note and distinguishes the possible results of nonobservance from each other. Signal Words WARNING CAUTION Attention Note For a hazardous situation with medium risk, possibly resulting in injuries or death if not avoided. For a hazardous situation with low risk, resulting in damage to the device or the property or in the loss of data, or injuries if not avoided. For important information about the product. May lead to equipment damage if not avoided. For useful information about the product. Warning Symbols Electrical Shock Hazard General Hazard Alternating Current Biohazard Explosion Hazard Corrosive Hazard Ohaus Corporation www.ohaus.com 1-1 FC5706 Centrifuge Service Manual CONTENT Warning and information signs on the surface of centrifuge. 1.3 SAFETY PRECAUTIONS. 1.3.1 User OHAUS centrifuges are intended exclusively for indoor use and for use by qualified personnel. This device may only be operated by trained specialist staff. They must have carefully read the operating manual and be familiar with the function of the device. 1.3.2 Rotor and Accessories Only OHAUS original rotors and accessories shall be used. Any other use or intended use is considered improper. OHAUS is not liable for damage resulting from improper use. CAUTION: Read all safety warnings before installing, making connections, or servicing this equipment. Failure to comply with these warnings could result in personal injury and/or property damage. Retain instructions for future reference. 1.3.3 Measures for your protection WARNING: Never work in an environment subject to explosion hazards! The housing of the instrument is not gas tight. (Explosion hazard due to spark formation, corrosion caused by the ingress of gases) WARNING: When using chemicals and solvents, comply with the instructions of the producer and the general lab safety rules. Ohaus Corporation www.ohaus.com 1-2 FC5706 Service Manual CHAPTER 1 GETTING STARTED WARNING: The centrifuge is not sealed. Use suitable protection measures when using the centrifuge for infectious and pathogenic samples. Follow appropriate safety precautions when handling these samples. 1.3.4 Exclude the following environmental influences Powerful vibrations Direct sunlight Atmospheric humidity greater than 80% Corrosive gases present Temperatures below 2 °C and above 35 °C Powerful electric or magnetic fields: WARNING: Electrical shock hazards exist within the housing. The housing should only be opened by authorized and qualified personnel. Remove all power connections to the unit before opening. 1.3.5 Measures for operational safety Do not unscrew the two halves of the housing Dry off any liquid spills immediately! The instrument is not watertight Only use a power cord with a rating that exceeds the specifications on the equipment label. Only connect the power cord to a properly grounded power receptable. Do not position the equipment such that it is difficult to disconnect the power cord from the power receptacle. Make sure that the power cord does not pose a potential obstacle or tripping hazard. The equipment is for indoor use only. Use the equipment only in dry locations. Use only approved accessories. Operate the equipment only under ambient conditions specified in these instructions. Disconnect the equipment from the power supply when cleaning. Do not operate the equipment in hazardous or unstable environments. Service should only be performed by authorized personnel 1.3.6 Danger and precautions To protect people and the environment the following precautions should be observed: During centrifugation, the presences of people are prohibited within 30 cm around the centrifuge according to the regulations of EN 61010-2-020. FC5706 is not explosion-proof and must therefore not be operated in explosion-endangered areas or locations. Centrifugation of flammable, explosive, radioactive, or such substances, which Chemically react with high energy, is strictly prohibited. The final decision on the risks associated with the use of such substances is the responsibility of the user of the centrifuge. Never spin toxic or pathogenic material without adequate safety precautions, i.e. centrifugation of buckets / tubes with missing or defective hermetic sealing is strictly prohibited. The user is obliged to perform appropriate disinfection procedures in case dangerous substances have contaminated the Ohaus Corporation www.ohaus.com 1-1 1-3 FC5706 Centrifuge Service Manual CONTENT centrifuge and or its accessories. When centrifuging infectious substances, always pay attention to the general laboratory precautions. If necessary, contact your safety officer! It is prohibited to run the centrifuge with rotors other than listed for this unit. Under no circumstances open the lid of the centrifuge while the rotor is still running or rotating with a speed of > 2m/s 1.4 SERVICE FACILITIES To service a centrifuge, the service area should meet the following requirements: 1.5 Area must be clean and air must not contain excessive dust particles. Work surface must be stable and level. Use an approved Electro-Static Device. TOOLS AND TEST EQUIPMENT REQUIRED 1.5.1 Standard Tools and Test Equipment 1. Flat and Philip screws drivers, tweezers, adjustable open wrenches and socket set (with drive socket sets from 4mm-14mm, Ratchet and drive extension bar.) Ohaus Corporation www.ohaus.com 1-4 FC5706 Service Manual CHAPTER 1 GETTING STARTED 1.6 Transporting and Packing of the Centrifuge FC5706. 1.6.1 Transport. • Please transport the device in the original packaging. • Use a transport aid for transporting over longer distances. 1.6.2 Packing. Pack the centrifuge in reverse order using the equipment original packing. 1.7. TECHNICAL DATA 1.7.1 Acceleration and Deceleration times FC5706. Rotor-number 30130880 6x5ml 30130877 12x5ml 30130878 6x50ml Acceleration values Deceleration values level 0 level 9 level 0 level9 35 8 25 7 95 33 257 51 91 41 274 52 in seconds Acceleration time Deceleration time -1 -1 from 0 min -> Umax from Umax -> 0 min 1.7.2 Imbalance shut-off data FC5706 (120V / 230 V ) Rotornumber Shut off speed (approx. values) in rpm Permitted imbalance in gram Imbalance shut-off in gram 30130877 2750 11 12 30130878 2850 10 11 30130880 2850 4 5 Ohaus Corporation www.ohaus.com 1-1 1-5 FC5706 Centrifuge Service Manual CHAPTER 1 GETTING STARTED 1.7.3 Specifications. Ohaus Corporation www.ohaus.com 1-2 1-6 FC5706 Centrifuge Service Manual CHAPTER 1 GETTING STARTED 1.8 SERVICE INSTRUCTIONS 1.8.1 General technical description The unit is equipped with several safety features: • Imbalance detection • Lid lock does not open until the standstill of the centrifuge • Rotor over speed protection After switching on the centrifuge an automatic calibration of the movement sensor will be done. Please follow below mentioned safety instructions for any kind of service actions: An equipment Redemption Form or Decontamination Certificate should be available before servicing the equipment. Remove all power connections to the unit before opening. Electrical shock hazards exist within the housing. The housing should only be opened by authorized and qualified personnel. Do not leave units unsupervised, when parts of the housing have been removed and the unit is still connected to the main power supply. Do not bypass the lid’s safety contacts and never work with the unit’s lid open. Never work in an environment subject to explosion hazards! The housing of the instrument is not gas tight. (Explosion hazard due to spark formation, corrosion caused by the ingress of gases) When using chemicals and solvents, comply with the instructions of the producer and the general lab safety rules. The centrifuge is not sealed. Use suitable protection measures when using the centrifuge for infectious and pathogenic samples. Follow appropriate safety precautions when handling these samples. FC5706 Centrifuge Service Manual 1-3 1-7 Ohaus Corporation www.ohaus.com CHAPTER 1 GETTING STARTED Equipment Redemption Form or Decontamination Certificate 1-8 Ohaus Corporation www.ohaus.com 1-4 FC5706 Centrifuge Service Manual CHAPTER 1 GETTING STARTED 1.8.2 Electrical and electronic components 1.8.2.1 Control board The control board consists of one plate. The board can only be exchanged completely. If there is a defect you have to exchange the complete board. All signal lines lead to the control board. The PCB controls the entire centrifuge. Figure 1: Control board 1-9 FC5706 Centrifuge Service Manual 1-5 Ohaus Corporation www.ohaus.com CHAPTER 1 GETTING STARTED 1.8.2.2 Rotor recognition The centrifuge will recognize the inputted rotor through the set up in the control panel. As soon as the lid get closed the rotor number will be indicated in the speed display. If the pre-selected rpm is higher than the permitted rpm of the rotor, the rpm pre-selection indication will flash when starting the centrifuge. But the regulation will accelerate the rotor only to its permitted rpm. Do not use a rotor, which isn't set to the control panel. 1.8.2.3 Speed signal The actual speed is extracted by a hall-effect-sensor placed on the lower side of the motor. There is a “preset/actual "comparison in the control board. Thereupon a new “actual-signal” is given by the control board to the converter. Figure 2 1.8.2.4 Lid mechanism The micro switch in the mechanism of the lid lock controls the correct closing of the centrifuge lid. The switch may never be bypassed. The lid lock is unlatched by an magnet, receiving its signal from the control board. The actual state is indicated in the display (see M1, M2). Figure 3 Ohaus Corporation www.ohaus.com 1-6 1-10 FC5706 Centrifuge Service Manual CHAPTER 1 GETTING STARTED 1.8.2.5 Imbalance detection The imbalance detection is effected by a movement sensor, which is placed on the lower side of the motor and is controlling the oscillating motion of the motor. The unit stopps when the oscillating motions are too strong. Therefore you have to follow the adjustment instructions stated by the manufacturer. FC5706 Centrifuge Service Manual 1-7 1-11 Ohaus Corporation www.ohaus.com CHAPTER 1 GETTING STARTED 1.9 LCD Display The following picture shows the individual elements of the LCD-display. Figure 4 Ohaus Corporation www.ohaus.com 1-8 1-12 FC5706 Centrifuge Service Manual CHAPTER 1 GETTING STARTED 1.10 Function label. The function label consists of one LCD-display, one potentiometer (8), the upper front housing and the foil keyboard. These parts can be exchanged separate. The potentiometer (1) regulates all parameters which are adjustable by pressing a key and which are indicated in the LCDdisplay. Inside the time display of the control panel the error message is indicated if there occur any troubles Figure 5 FC5706 Centrifuge Service Manual 1-9 1-13 Ohaus Corporation www.ohaus.com CHAPTER 2 SERVICE MENU 2.1 SERVICE MENU The operation menu helps the service personnel to locate defects. It is divided in two parts, which are graded in several areas again from chapter 2.1.1 to 2.2.2. Part 1 is accessible for the USER and different points can be read respectively settled. This is also described in the instruction manual. Part 2 is for internal use respectively for OHAUS trained service personnel only. 2.1.1 Activation of the Service Menu (part 1) The menu can be started as follows: Open lid of the centrifuge and switch off main switch. Press the key „time“ (6) and „door open“ (7) hold them and at the same time switch on the unit. If the centrifuge is still turned off, press simultaneously the keys „time“ (6) and „lid“ (7) and turn on the main switch of the centrifuge. Now release both keys again. As a result a display test is executed for approx. 5 seconds Figure 1 Now it follows a display test for about 5 seconds as shown here under in figure 8. Now you have entered the Service mode. By pressing the key „accel/decel“ (5) you will get to the submenus. Now in the display “acc/dec“ (A-2) the word “service“ (M12) will flash when you press Accel/Decel (5) and "service" will stop flashing after 5 sec. Only as long as this word is flashing, you can scroll through the further submenus with the potentiometer (8). You have to repeat this step continuously to enter the different submenus. FC5706 Centrifuge Service Manual 2-1 Ohaus Corporation www.ohaus.com CHAPTER 2 SEVICE MENU 2.1.2 Submenu Motor Starts Here you can read off the number of motor starts. Activate the operation menu as described in chapter 2.1.1. Turn the potentiometer (8) until the special digit “service A “appears in the display „acc/dec” (A-2), see figure 9 Figure 2 In the display “rpm/rcf“ (A-1) the number of motor starts is indicated now. 2.1.3 Submenu Duty Cycle Here you can read off the duty cycle of the unit. Activate the operation menu as described in chapter 2.1.1. Turn the potentiometer (8) until the special digit “service H“ appears in the display “acc/dec” (A-2). Figure 3 Inside the display “rpm/rcf“ (A-1) now the duty cycle is indicated. Ohaus Corporation www.ohaus.com 2-2 FC5706 Centrifuge Service Manual CHAPTER 2 SERVICE MENU 2.1.4 Submenu Running Time Here you can read off the operating hours of the motor. Activate the operation menu as described in chapter 2.1.1. Turn the potentiometer until the special digit “service h“ appears in the display “acc/dec” (A-2). Figure 4 In the display “rpm/rcf“ (A-1) the running time of the motor is indicated now. 2.1.5 Submenu software status Here you can read off the software status. Activate the operation menu as described in chapter 2.1.1. Turn the potentiometer (1) until the special digit ”service S“ appears in the display „acc/dec” (A-2). Figure 5 In the display “rpm/rcf“ (A-1) the actual software status is indicated now. FC5706 Centrifuge Service Manual 2-3 Ohaus Corporation www.ohaus.com CHAPTER 2 SEVICE MENU 2.1.6 Submenu Error Memory Here the last 99 occurred error messages can be indicated. Activate the operation menu as described in chapter 2.1.1. Turn the potentiometer (8) until the special digit “service E“ appears in the display “acc/dec” (A-2). Figure 6 By pressing the key „rpm/rcf“ (4) the display “rpm/rcf“ (A-1) is activated and you can scroll through the error list with the potentiometer (8). Now the last 99 occurred error messages are indicated in the display “rpm/rcf“ (A-1). Whereas the first two digits describe the place number and the last two digits do describe the occurred error. Look at chapter 3.5 "Errors that may be indicated in the LCD display". Ohaus Corporation www.ohaus.com 2-4 FC5706 Centrifuge Service Manual CHAPTER 2 SERVICE MENU 2.1.7 Submenu Keyboard Test The keyboard test is used for checking the correct function of the foil keyboard. Activate the operation menu as described in chapter 2.1.1. Turn the potentiometer (8) until the special digit “service P“ appears in the display “acc/dec“ (A-2). Figure 7 By pressing each key the word “PrESS“ switches from the bottom to the top line in the display “rpm/rcf“ (A-1). The key accel/decel (5) excluded. 2.1.8 Subemenu Activation / Deactivation of the imbalance sensor Activate the operation menu as described in chapter 9.3.1. By pressing the key “accel/decel“ (5) the several sub-menus are activated. Turn the potentiometer until the special digit "Service u" appears in the display “acc/dec“. In the display “rpm/rcf“ (A-1) appears the word „unbAL“. By pressing the key “RPM/RCF“ (4) the menu is activated. Turn the potentiometer until the words „on“ or „off“ are indicated in the display “rpm/rcf“ (A-1). on = imbalance sensor is activated off = imbalance sensor is deactivated FC5706 Centrifuge Service Manual 2-5 Ohaus Corporation www.ohaus.com CHAPTER 2 SEVICE MENU Figure 8 2.2 Activation of the Service Menu (Part 2) To get access to the second level of the service menu you have to press the key stop (3) for longer than one second. Now you are asked for a code in the display “rpm/rcf“ (A-2) – adjust the code “9876“ with the potentiometer (8) and press once again the key stop (3). Figure 9 Now you can carry out the below shown adjustments: Ohaus Corporation www.ohaus.com 2-6 FC5706 Centrifuge Service Manual CHAPTER 2 SERVICE MENU 2.2.1 Centrifuge Model Here you can see the centrifuge models which are stored on the control board. Activate the operation menu as described in chapter 9.3.1. Activate the service menu as described in chapter 9.4.1. Turn the potentiometer (8) until the special digit “service t“ appears in the display “acc/dec“ (A-2). Examples: Figure 10 2.2.2 Submenu Adjustment/Correction of the imbalance cut off value: Here you can adjust or correct the imbalance cut off value. In the factory has been setup an imbalance cut off value. With this settled value the unit should run through. Through the transport or the setup of the unit it may occur that this value will react unlike. In case the unit does already cut off at the adjusted value you can increase this value by adjusting this value > 0. In case the unit does not cut off until you can decrease this value by adjusting this value < 0. The suitable value must be settled by service personnel only. After the correction there is another check indispensable. You have to make several tests. Activate the service menu as described under 2.1.1 „Activation of the operation menu (Part 1)“. Activate the operation menu as described under 2.2 „Activation of the service menu (Part 2)“. Press the button "accel/decel" (5). Turn the potentiometer (8) until the special digit „n“ appears in the display "acc/dec" (A-2). FC5706 Centrifuge Service Manual 2-7 Ohaus Corporation www.ohaus.com CHAPTER 2 SEVICE MENU Figure 11 Press the button "rpm/rcf" (4). The display "rpm/rcf" (A-1) is now activated and you can choose the respective setup between -30 and 20 with the potentiometer (8). Note: After all points have been reviewed and/or set up, you have to press shortly the key "start" to store all parameters. Otherwise the setups were all for nothing. If the storage has been successful in the display „rpm/rcf“ the value of the imbalance sensor and the word „StorE“ are indicated. Figure 12 Ohaus Corporation www.ohaus.com 2-8 FC5706 Centrifuge Service Manual CHAPTER 3 MAINTENANCE PROCEDURES 3.1 PREVENTIVE MAINTENANCE 3.1.1 General Care: Maintenance of the centrifuge is confined to keeping the rotor, the rotor chamber and the rotor accessories clean as well as to regularly lubricating the rotor insert bolts of a swing out rotor (if available). Lubricants containing molycote and graphite are not allowed. Please pay special attention to anodized aluminium parts. Breakage of rotors can be caused even by slightest damages. In case of rotors, buckets or tube racks getting in touch with corrosive substances the concerned spots have to be cleaned carefully. Corrosive substances are for instance: alkalis, alkaline soap solutions, alkaline amines, concentrated acids, solutions containing heavy metals, water-free chlorinated solvents, saline solutions, e.g. salt water, phenol, halogenated hydrocarbons. Cleaning – units, rotors, accessories: - Turn the device off and disconnect it from the power supply before you begin any cleaning or disinfecting. Do not pour liquids into the housing interior. - Do not spray disinfectant on the device. - Thorough cleaning not only has its purpose in hygiene but also in avoiding corrosion based on pollution. - In order to avoid damaging anodized parts such as rotors, reduction plates etc., only pH-neutral Detergents with a pH-value of 6-8 may be used for cleaning. Alkaline cleaning agents (pH-value > 8) must not be used. - After cleaning, please ensure all parts are dried thoroughly, either by hand or in a hot-air cabinet (max. Temperature + 50°C). - It is necessary to coat anodized aluminium parts with anti-corrosion oil regularly in order to increase their life-spans and reduce corrosion predisposition. - Due to humidity or not hermetically sealed samples, condensate may be formed. The condensate has to be removed from the rotor chamber with a soft cloth regularly. FC5706 Centrifuge Service Manual 3-1 Ohaus Corporation www.ohaus.com CHAPTER 3 MAINTENANCE PROCEDURES The maintenance procedure has to be repeated every 10 to 15 runs, but at least once a week! 3.1.2 - Connect the unit to the power supply, after the equipment is completely dry. - Do not carry out disinfection with UV-, beta- and gamma-rays or other high energy radiation. - Metal rotors can be autoclaved. - Rotor lid and adapters can also be autoclaved (max. 121°C, 20 min). - The tube racks are made of PP and can not be autoclaved at 134°C. Cleaning and disinfection of the unit 1. 2. 3. 4. 5. 6. 7. 8. 9. Open the lid before you turn off the unit. Disconnect it from the power supply. Open the rotor nut by turning the rotor key clockwise. Remove the rotor For cleaning and desinfection of the unit and the rotor chamber using the above mentioned cleaner. Clean all accessible areas of the device and its accessories, including the power cord with a damp cloth. Wash the rubber seals and rotor chamber thoroughly with water. Rub the dry rubber seals with glycerol or talc to prevent these to becoming brittle. Other components of the unit, e.g. the lid lock, motor shaft and rotor must not be greased. Dry the motor shaft with a soft, dry and lint-free cloth. Inspect the unit and accessories for damage. Remove at least every six months adherent dust from the ventilation slots in the centrifuge by using a brush. 3.1.3 Cleaning and disinfection of the rotor 1. Clean and disinfect the rotors, rotor lids and adapters with the above mentioned cleaner. 2. Use a bottle brush to clean and disinfect the rotor bores. 3. Rinse the rotor, rotor lid and adapter with water, especially type fixed angle rotor holes. 4. For drying of the rotors and accessories set them on a towel. Place the angle rotors with bores down, to dry them to. 5. Dry the rotor cone with a soft, dry and lint-free cloth and look for damage. Do not grease the rotor cone. 6. Place the dry motor onto the motor shaft. 7. Pull the rotor nut tight by using the rotor-key. Ohaus Corporation www.ohaus.com 3-2 FC5706 Centrifuge Service Manual CHAPTER 3 MAINTENANCE PROCEDURES 3.1.4 Disinfection of Aluminum-rotors In case of infectious material spilling into the centrifuge, the rotor and rotor chamber have to be disinfected right after the run. Rotors may be autoclaved at a maximum temperature of 121°C. 3.1.5 Disinfection of PP-rotors Autoclaving The recommended time for autoclaving: 15 – 20 min at 121°C (1 bar) Attention: The sterilization time of 20 min. must not be exceeded. Sterilization again and again will cause reduction of the mechanical resistance of the plastic material Before the autoclaving the PP-rotor and adapter must thoroughly be cleaned to avoid the burning in of dirty residues. You can disregard the consequences of some chemical residues to plastic materials at ambient temperatures. But at the high temperatures of the autoclaving those residues may corrode and destroy the plastic. The objects must be thoroughly washed up with distilled water after the cleaning but before the autoclaving. Residues of any cleaning liquids may cause fissures, whitening and stains. Gassterilization Boxes, bottles and rotors may be gassterilized with Ethylenoxyd. According to the duration of the application you may give long enough an airing to the items after the sterilization and before using them again. Attention: Because the temperature may rise during the sterilization, rotors, boxes and bottles must not be closed respectively must be totally unscrewed Chemical sterilization Bottles, boxes and rotors may be treated with the usual liquid disinfectants. Attention: Before applying a different decontamination method than recommended by the manufacturer, contact the manufacturer to ensure that it will not damage the unit or the rotor. FC5706 Centrifuge Service Manual 3-3 Ohaus Corporation www.ohaus.com CHAPTER 3 MAINTENANCE PROCEDURES 3.1.6 Glass breakage With high g-values, the rate of glass tube breakage increases. Glass splinters have to be removed immediately from rotor, buckets, adapters and the rotor chamber itself. Fine glass splinters will scratch and therefore damage the protective surface coating of a rotor. If glass splinters remain in the rotor chamber, fine metal dust will build up due to air circulation. This very fine, black metal dust will extremely pollute the rotor chamber, the rotor, the buckets and the samples. If necessary, replace the adapters, tubes and accessories to avoid further damages. Check the rotor bores regulary for residues and damages. Attention: Please check the relevant specifications of the tubes centrifuges with the manufacturer! 3.2 Service life of rotors, round and rectangular buckets, accessories Rotors and rotor lid made of aluminium or stainless steel, have an operating life of max. 7 years from first use. Transparent rotor lids and caps made of PC or PP as well as rotors, tube racks and adapters of PP have a maximum service life up to 3 years from first use. Condition for the operating life: Proper use, damage-free condition, recommended care. Ohaus Corporation www.ohaus.com 3-4 FC5706 Centrifuge Service Manual SERVICE INSTRUCTIONS 3.3 Mounting Support After performing any kind of assembling work, please make sure all the grounded contacts are connected correctly! 3.3.1 Replacing the front housing Begin with step 3.3.5 Remove the lower covering by putting a screw driver into the 2 notches and then lever the front part out. Pull the lower edge of the covering away from the mounting plate of the housing. Pull the covering out of the upper guiding rails downwards. Remove the interface cable on the control board. Figure 1 3.3.2 Replacing the incremental shaft encoder (potentiometer) Remove the cap on top of the incremental shaft encoder (see figure 23). With a socket wrench you can loosen the fastening nut. (socket wrench size 10mm) Ohaus Corporation www.ohaus.com 3-11 3-5 FC5706 Service Manual SERVICE INSTRUCTIONS Figure 2 Loosen all electrical contacts to the shaft encoder on the back side of the front housing. Figure 3 3.3.3 Replacing the display Loosen all electrical contacts to the display on the back of the front housing. Remove the 4 fastening screws of the display and pull away the display upwards. remov e Figure 4 Ohaus Corporation www.ohaus.com 3-10 3-6 FC5706 Service Manual SERVICE INSTRUCTIONS 3.3.4 Replacing the foil key board Remove the incremental shaft encoder and the display. Peel off the defective foil keyboard and clean the remaining glued joints. Glue the new foil keyboard precisely in the recess. Make sure the foil matches precisely and the window of the foil keyboard lies exactly over the display. Reassemble the control panel in reversed order and mount it back in the front housing. 3.3.5 Removing the housing Remove the control panel as described in chapter 3.3.5. Remove all screws on the lower side of the housing. Remove the housing upwards and remove all relevant electrical contacts on the control board. Reassemble the unit in reverse order. Left side of Centrifuge Right side of Centrifuge Figure 5 Ohaus Corporation www.ohaus.com 3-11 3-7 FC5706 Service Manual SERVICE INSTRUCTIONS 3.3.6 Replacing the rotor chamber or lid gasket Grasp under the lid gasket and lift out the rotor chamber piece by piece. Take care that the fixing ends are at the back part of the chamber (see figure 27). Start the mounting always with this glued ends. When mounting the rotor chamber make sure that the ventilation drilling behind on the right points to the corner of the housing (see figure 27) Place the new lid gasket on the plastic ring. Take care that the fixing points are at the back of the chamber. Reassemble the unit in reverse order. Figure 6 Ohaus Corporation www.ohaus.com 3-10 3-8 FC5706 Service Manual SERVICE INSTRUCTIONS 3.3.7 Removing the lid Open the lid as wide as possible. Hold the lid with one hand and remove the fixing screws of the hinges (see figure 28). The lid can now be removed completely. Fixing screws Figure 7 3.3.8 Replacing the hinges Remove the lid as described in chapter 3.3.7. Lay the lid with the upper side down on a smooth under packing to avoid any scratches. Loosen the screws of the respective hinges on the inner side of the lid and replace the hinges. remove Figure 8 Reassemble the unit in reverse order. Make sure the lid rests on the lid gasket straight and continuous. Tighten the fasting screws firmly at the backside of the unit after the adjustment Ohaus Corporation www.ohaus.com 3-11 3-9 FC5706 Service Manual SERVICE INSTRUCTIONS 3.3.9 Replacing the motor Remove the housing as described in chapter 3.3.5. Remove the connection cable to the motor on the control board. a) current supply of the motor b) speed and imbalance sensor remove Figure 9 Turn the motor fixing screws out of the rear side of the ground plate. Lift the motor out of the unit. When re-assembling the spare motor, take care of the wirings, as they must not be jammed. Re-assemble the unit in reverse order. Ohaus Corporation www.ohaus.com 3-10 FC5706 Service Manual SERVICE INSTRUCTIONS 3.3.10 Replacing the power board / control board Remove the housing as described in chapter 3.3.5. Remove all cable connections to the control board. Remove the four fixings screws and take the control board out. remove Figure 10 Put in the new control board, connect all electrical contacts and re-assemble the unit in reverse order. 3.3.11 Checkup the imbalance sensor Movement sensor: • It is possible to adjust/correct the imbalance cut off value see chapter 2.2.2. • Should appear any difficulties with the imbalance, please give us an exact description of it as well as the serial number of the unit and the rotor type. Ohaus Corporation www.ohaus.com 3-11 FC5706 Service Manual SERVICE INSTRUCTIONS 3.3.12 Replacing the imbalance - (movement sensor) and speed sensor • Remove the housing as described in chapter 3.5.5 • Remove the motor as described in chapter 3.3.9. • Lay the motor down on it's side and remove the 4 fixing screws of the swinging rubber and the two fixing screws of the green board on the rear side (look up in chapter 1.5.2.5). • Pull off the speed magnet carefully. Attention: Risk of breakage! • Replace the board. • Glue the speed magnet with super glue again in the right position and re-assemble the unit in reverse order. 3.2.13 Replacing the lid lock • Remove the control panel as described in chapter 3.3.5. • Remove the electrical contact of the lid lock on the control board (see figure 31). • Remove the string of the emergency release of the lid lock on the control board (see figure 32). • Remove the fixing screws on the housing and put in the new lid lock. • Make sure that the lid rests on the lid gasket straight and continuous while fastening. Tighten the fastening screws firmly after the replacement. Ohaus Corporation www.ohaus.com 3-10 3-12 FC5706 Service Manual SERVICE INSTRUCTIONS remove Figure 11 3.2.14 Adjustment of the lid: 1.) Lay the lid down onto the centrifuges seal. Afterwards tighten the screws of the hinges under a slight pressure onto the lid. 2.) Put some washers underneath of the lid lock, in that way that the lid latch is centric to the closing bar. 3.) Adjust the height of the lid lock, that the distance between the lid up to the housing is about 8 mm to 4 mm. Ohaus Corporation www.ohaus.com 3-11 3-13 FC5706 Service Manual SERVICE INSTRUCTIONS 3.4 Major internal cable connection. After performing any internal repairs it is important to check if the cable connections are correct and all grounding is properly connected (housing and bottom housing) Centrifuge grounding: A=Grounding from Top Housing B= Grounding from Motor C= Grounding from Connector, Power. Switch, power connection and Rectifier, Bridge connection. A) Switch, Power connections: A = From/To Main PCBA B= From/To Connector, Power B) Rectifier, Bridge connections: C= From Transformer (Red cables) D= From/To main PCBA (RED and BLACK cables) Note: kindly take note on the color and position of the cable connections. Ohaus Corporation www.ohaus.com 3-10 3-14 FC5706 Service Manual SERVICE INSTRUCTIONS Transformer cable connection: A- A1 (Brown)= to Main PCBA point X21.1 A2 (Blue) = to Main PCBA point X21.3 B- B1 (Brown)= to Main PCBA point X21.4 B2 (Blue)= to Main PCBA point X21.6 Main PCBA connection: A= (Black/Red) from Motor B= (Black/Red) from Rectifier, Bridge = (White) from Transformer C= From Motor Lid Lock connection: A=Black Cable B=Gray Cable Ohaus Corporation www.ohaus.com 3-11 3-15 FC5706 Service Manual CHAPTER 3 MAINTENANCE PROCEDURES 3.5 Trouble Shooting 3.5.1 Error messages: Cause / Solution Preface: The error messages are listed to help localize possible errors faster. The diagnosis, referred to this chapter may not always be the case, as they are only theoretically occurring errors and solutions. Always, please keep us informed about any kind of error occurring, which is not listed in this chapter. Only through your information we are able to improve this service manual. Many thanks in advance for your support. 3.5.2 Possible error messages and their solutions 3.5.2.1 Lid release during power failure In case of power failure or malfunction, the lid of the centrifuge can be opened manually in order to protect your samples. Please proceed as follows: • Switch the centrifuge off and unplug the power cord. • At the left side of the centrifuge there is a plastic stopper. • Remove this stopper. Behind it there is a string (see figure 33). • Now open the lid of the centrifuge by pulling this string, during you press the lid slightlly • Put the string and the plastic stopper back again. • Switch the centrifuge on again, for go on working. Warning: Don't put your hands in the rotor chamber as long as the rotor is still spinning! FC5706 Centrifuge Service Manual 3-12 3-16 Ohaus Corporation www.ohaus.com CHAPTER 3 MAINTENANCE PROCEDURES Figure 12 3.5.2.2.1 Description of the error message system The error message is shown in the "time" display through particular numbers. At the same time the word “error“ is indicated in the display (see figure 34). Figure 13 Ohaus Corporation www.ohaus.com 3-13 3-17 FC5706 Centrifuge Service Manual CHAPTER 3 MAINTENANCE PROCEDURES 3.6 Error Codes Error No. 1 Description Imbalance arose Cause Excessive acceleration at the sensor 2 Imbalance sensor is defective Rotary encoder circuit board is defective, cable break, plug is loose (between control unit to frequency converter), control unit is defective 4 Imbalance switch has been activated for longer than 5 seconds Imbalance switch incorrectly adjusted, imbalance switch is defective, cable break, plug is loose (between control unit to frequency converter), control unit is defective 11 Temperature sensor is defective 12 Chamber over temperature Temperature sensor is defective, cable break, plug is loose (between control units to frequency converter), control unit is defective. Relay on the controller is defective, cooling is defective, heating is defective, ventilation is defective. 14 Problem with the speed sensor. Lid is closed for a certain time. The blocking time is shown in the display and replaced with "CLOSE Lid". Rotary encoder circuit board is defective, cable break, plug is loosening (between control units to frequency converter), motor is blocked, control unit is defective, frequency converter is defective. 33 Open lid while the motor is running Control switch of the lid lock is defective FC5706 Centrifuge Service Manual 3-12 3-18 Ohaus Corporation www.ohaus.com CHAPTER 3 MAINTENANCE PROCEDURES Error No. 55 Description Over speed Cause Transmission error, firmware error, frequency converter us defective. 60 Intermediate circuit under voltage Motor defective, control board defective 70 Relay hang-up Relay K1 and K2 of the control board is defective Ohaus Corporation www.ohaus.com 3-13 3-19 FC5706 Centrifuge Service Manual Ohaus Corporation 7 Campus Drive Suite 310 Parsippany, NJ 07054 USA Tel: +1 (973) 377-9000 Fax: +1 (973) 944-7177 With offices worldwide www.ohaus.com *30243095* P/N 30243095 A © 2014 Ohaus Corporation, all rights reserved ™ Registered trademark of Ohaus Corporation. The information contained in this manual is believed to be accurate at the time of publication, but Ohaus Corporation assumes no liability arising from the use or misuse of this material. Reproduction of this material is strictly prohibited. Material in this manual is subject to change.
advertisement
Key Features
- Digital display
- Rotor recognition
- Imbalance detection
- Lid lock
- Adjustable speed
- Timer
- Acceleration/deceleration control