Roper Rhodes TR9016 is a sensor flush plate designed for wall hung frame cisterns and In-wall cisterns. It features a dual flush system, activated by touching either the shorter or longer decal side. The plate includes a battery-powered sensor system and a manual override button for use in case of battery exhaustion. Furthermore, the sensor provides LED indicators to signal successful activation and low battery status. The plate offers a secure installation with fixing arms and a mounting bracket.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Roper Rhodes TR9016 Dual Flush Sensor Plate Installation Instructions | Manualzz
Dual Flush Sensor Flush Plate
Installation & Operation Instructions - For Domestic Use Only
Please read completely before commencing. Retain for future reference
TR9016
Introduction
This sensor flush plate is compatible with wall hung frame cisterns and In-wall cisterns from Roper Rhodes
Group.
minimum
15.5mm
For In-wall installation the front of frame to front of finished wall minimum depth should be 15.5mm.
If used with a furniture concealed cistern ensure a clearance of 105mm is left between the cistern and the front
of the furniture fascia surface to allow adequate installation.
Battery Installation (Batteries not included)
Open the glass plate by pushing it towards the top and then tilting it
forwards. The clip chain will allow it to hang, make sure it’s secured
before dropping it.
2
Battery
Holder
1
Good quality Alkaline batteries will last for approximately one year in
normal domestic conditions.
Once batteries are due to be replaced, a continuous alarm will be heard
for 10s, indicating that battery power is low and that they are due to be
changed. The LED lights will also flash.
Remove the battery holder and insert 4x AA batteries into the battery
compartment, noting the polarity on the battery holder. Slide back into
place and replace the glass fascia. The LEDs will Illuminate, indicating
that the flush plate is ready to be used.
Batteries are totally exhausted when the LED lights are continuously
flashing (twice per second). Please replace the batteries immediately.
A manual over-ride button is available if batteries are totally exhausted.
Installation
1. Cut the protective casing of the in-wall cistern in-line with the
finished wall surface.
3. Remove the front fascia panel completely. Push the glass front to the
top and tilt the top towards you. Un-clip the glass fascia by expanding
the clip links and keep aside until installation is completed. Remove
the battery holder also to avoid damage.
2
1
2. Screw the fixing arms (supplied in the box) onto the cistern.
The rods may need cutting down depending on the thickness of the
finished wall/surface.
Fixing Arms
Clip links
Dual Flush Sensor Flush Plate
Installation & Operation Instructions - For Domestic Use Only
Please read completely before commencing. Retain for future reference
4. Connect the air hoses from the cistern to the flush plate as shown.
Attach the blue hose to the half moon symbol and the transparent hose
to the full moon symbol.
TR9016
5. Make sure the cistern is fully commissioned before mounting the
bracket in place.
Locate the mounting bracket onto the fixing arms and secure the top
left and bottom right corners with the screws provided and tighten
with a screwdriver. Be careful not to overtighten.
Mounting
bracket
Fixing Arms
Re-connect the clip links and cable ribbon to the glass fascia and insert
the battery holder. Place the front glass plate and remove the protective film prior to testing its functioning. Once correctly attached the
flush plate will illuminate for a couple of seconds.
Specification
Operation
Reduced Flush: Touch the shorter decal side with your hand to activate
the flush. The LED lights will Illuminate.
Full Flush: Touch the longer decal side with your hand to activate the
flush. The LED lights will Illuminate.
If the flush plate is touched for more than 5 seconds it won’t flush.
Batteries: 4x AA (LR6) Alkaline Batteries (Not supplied)
Ingress Protection: IPX4
At the end of life, please dispose of batteries and unit where municipal
recycling facilities exist. Do not dispose of in the regular waste.
This product is only suitable for domestic use.
Manual over-ride
If batteries are exhausted completely, the glass fascia can be removed
to reveal the manual flush button.
The manual over-ride is not intended as a long term solution. When
using the manual push button, un-plug the cable ribbon and take the
front glass fascia off the chain links. Keep safe to prevent damage.
Manual Flush
v3. 02.18
Brought to you by the Roper Rhodes Group
Brassmill Lane Trading Estate
Bath
BA1 3JF
t: 01225 303900

advertisement

Key Features

  • Dual flush system
  • Sensor activation
  • LED indicators
  • Manual override
  • Secure installation
  • Battery-powered sensor

Frequently Answers and Questions

How do I activate the flush?
To activate the reduced flush, touch the shorter decal side. To activate the full flush, touch the longer decal side.
What happens when the batteries are low?
A continuous alarm will sound for 10 seconds, and the LED lights will flash. Replace the batteries immediately.
How do I install the flush plate?
Follow the steps in the installation instructions, ensuring to connect the air hoses correctly and secure the mounting bracket to the fixing arms.