AMG AMG4643-SF Instruction Manual

AMG AMG4643-SF Instruction Manual

The AMG AMG4643-SF is a standalone video transmit unit designed to send four video signals and one data signal over a single multimode fiber optic cable. It is intended for point-to-point configurations with the AMG4644-SF or AMG4644R-SF receive unit. The device is powered by the AMG2003 standalone power supply and features various data interface options including RS232, RS422 and RS485.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

AMG AMG4643-SF Instruction Manual | Manualzz
AMG4643-SF
Instruction Manual
4 Video Transmit Unit with Bi-directional Data Channel
The AMG4643-SF is a standalone zero channel video transmit unit designed to transmit 4 video
signals and transmit and receive 1 data signal over one Multimode fibre.
The AMG4643-SF is designed to be powered using an AMG2003 standalone power supply.
The AMG4643-SF is designed to operate with AMG4644-SF or rackmount equivalent AMG4644R-SF
zero channel video receive unit in a point to point configuration.
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page 1 of 8
AMG4643-SF Instruction Sheet
D16596-03.doc
Contents
Introduction
3
Unit Functional Schematic.................................................................................................................. 3
Optical Connection ............................................................................................................................. 3
Connections
4
Video Input Connections .................................................................................................................... 4
Optical Connections ........................................................................................................................... 4
Power Connection .............................................................................................................................. 4
Data and Audio Channel Connections ............................................................................................... 4
Data and Audio Channel Configuration
5
Data and Audio Channel Configuration.............................................................................................. 5
Data Interface Connections Channel A .............................................................................................. 5
Data Channel A Configuration............................................................................................................ 5
Front Panel Indicators
6
Power LED.......................................................................................................................................... 6
Video Input LED’s ............................................................................................................................... 6
Fibre Optic LED’s ............................................................................................................................... 6
Low Speed Data LEDs ....................................................................................................................... 6
Physical Information
7
Dimensions ......................................................................................................................................... 7
Mounting Details ................................................................................................................................. 7
Removal / replacement from / to the Case......................................................................................... 7
Safety
7
Maintenance and Repair
7
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page 2 of 8
AMG4643-SF Instruction Sheet
D16596-03.doc
Introduction
Unit Functional Schematic
The AMG4643-SF transmits up to 4 video
and 1 data signals to the AMG4644-SF.
It also receives 1 data signal transmitted
from the AMG4644-SF.
Optical Connection
The AMG4643-SF is connected as illustrated below when used with an AMG4644-SF receive unit
acting as a point to point system.
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page 3 of 8
AMG4643-SF Instruction Sheet
D16596-03.doc
Connections
Video Input Connections
No. of channels ....................................4
Connector ............................................75 ohm BNC Socket.
Input Impedance ..................................75 ohm terminated.
Input Level ...........................................1 volt p-p nominal
Frequency Response...........................10Hz to 7MHz.
Optical Connections
PRIMARY OPTO OUT
Connector ............................................LC/PC
Primary Optical Launch Power ............-5dBm
Transmit Wavelength...........................1550nm
Primary Optical Sensitivity ...................-22dBm
Receive Wavelength............................1310nm
Optical Fibre ........................................Multimode 50/125 or 62.5/125**
**Note: the transmission distance is limited by the bandwidth of the Multimode optical fibre. The optical
data rate is 1.25Gbits/s. The maximum bandwidth specification at this data rate for Multimode fibre is
2km. although in most cases the units will operate successfully over longer fibre lengths. It is
advisable however for distances greater than 2km, to have the optical fibre tested.
Power Connection
Connector Type ...................................2.1mm screw lock long power jack – centre positive
Connector Partno.................................Switchcraft S761K, AMG G16125-00
Supply Voltage.....................................13.5 to 18.0 Volts DC.
Maximum Power .................................5 Watts
Data and Audio Channel Connections
DATA CHANNEL A
Data Channel A ...................................1 channel
Data Connector....................................RJ45
Channel A Interface
On Board Data Interface – RS232, RS422 or RS485. Selected by slide switch
above RJ45 connector.
RS485 – switch position - high (closest to BNC connections)
RS422 – switch position – middle
RS232 – switch position – low (furthest from BNC connections)
DATA CHANNEL B
Data Channel B ...................................Not Present
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page 4 of 8
AMG4643-SF Instruction Sheet
D16596-03.doc
Data and Audio Channel Configuration
Data and Audio Channel Configuration
The AMG4643-SF and rackmount equivalent AMG4643R-SF sends and receives data to/from
Channel A. Channel B is not available. Channel A is a single data interface selectable by the user with
the slide switch on the rear panel.
Data Interface Connections Channel A
Channel A
RJ45 Pin
No.
RS485
[switch high]
Cat 5/6 Cable
Colour Code T568B
1
RS422
[switch mid]
IN + (A)
RS232
[switch low]
GND
White/orange
2
IN - (B)
IN
Orange
3
White/green
4
Blue
5
White/blue
6
Green
7
IN/OUT + (A)
OUT + (A)
N/A
White/brown
8
IN/OUT - (B)
OUT - (B)
OUT
Brown
Note: (A) or (B) in brackets in above table refers to RS485 / RS422 data specification, not Channel A,
Channel B.
Data Channel A Configuration
Channel A is always present and allows for a RS232, RS422 (full duplex, four wire) or RS485 (half
duplex, two wire) interface depending on the position of the switch located above the RJ45 connector.
The switch signifies the presence of the X16004 Low Speed Data/Audio Interface Board. If there are
LED's present on the RJ45 connector then an X16003 Ethernet Interface Board is fitted.
The data input for both the RS485 and the RS422 modes detects a tri-state input condition by
monitoring the differential voltage level across the input. A differential level below 600mV positive or
negative will be detected as a tri-state condition. A level above 600mV positive or negative will be
detected as a logic 1 or logic zero respectively. It is important therefore to terminate the RS485 bus or
the RS422 input bus using 120Ω if a pre-bias is present on the RS485 or RS422 bus.
A large number of third party equipment manufacturers apply a pre-bias on their RS485 bus. This prebias is applied by pulling one arm of the RS485 bus high (+5 volts) and the other arm low (0 volts)
using high value resistors within the third party equipment. In order to ensure that the AMG equipment
detects a tri-state condition, then these resistors should have a value above 5kΩ. If the third party
bias resistors are less the 750Ω the bus can be double or triple terminated as required to ensure that a
tri-state level is detected.
Note: The Data Channel A is shipped from the factory set up for RS485 operation unless otherwise
requested.
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page 5 of 8
AMG4643-SF Instruction Sheet
D16596-03.doc
Front Panel Indicators
Power LED
Power...................................................Green
Off
-
unit powered
no power applied to unit
-
video signal present on input BNC
channel present but no video on I/P BNC
Primary Opto Sync TX .........................Green
Off
-
optical channel transmitting
optical channel not transmitting
Primary Opto Sync RX.........................Green
Org
Off
-
optical channel receiving
optical channel receiving but not sync.
optical channel not transmitting
Channel A
Data Present TX (RS485 or RS422) ...Green
Red
Off
-
logic zero (+V, -V) present on IN+, INlogic one (-V,V+) present on IN+, INtri-state off or no connection on IN+, IN-
Data Present TX (RS232)....................Green
Red
Off
-
logic zero (+V) present on input IN+
logic transitions present on input IN+
logic one (-V) present on input IN+
Video Input LED’s
Video Present CH1-4...........................Green
R/G
Fibre Optic LED’s
Low Speed Data LEDs
This represents the data signals being transmitted on the optical fibre
Data Present RX (RS485 or RS422) ...Green
Red
Off
-
logic zero (+V,-V) present on OUT+, OUTlogic one (-V,+V) present on OUT+, OUTtri-state off or no connection on OUT+, OUT-
Data Present RX (RS232) ...................Green
Red
Off
-
logic zero (+V) present on OUT+
logic transitions present on OUT+
logic one (-V) present on OUT+
This represents the data signals being received on the optical fibre
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page 6 of 8
AMG4643-SF Instruction Sheet
D16596-03.doc
Physical Information
Dimensions
Height .................................................. 112mm
Width ................................................... 170mm (excluding connectors)
Depth ................................................... 70mm
Weight ................................................. 750grams
Mounting Details
The AMG unit is supplied with a clip-on mounting bracket which should be attached to a panel or wall
using 2 off 4.0mm screws, see diagram on page 1 for dimensions. The unit is clipped into the
mounting bracket, and is then held firmly in position.
Removal / replacement from / to the Case
Note: - The AMG unit PCB's are static sensitive. Handle with proper care and use normal electrostatic
discharge (ESD) procedures. Use properly grounded protection (for example, wrist straps) when
handling the PCB.
To remove units from the case to access the data expansion boards and the daughter boards, remove
the 2 or 4 fixing screws on the rear panel and slide the PCB's out of the case.
Ensure that the fibres do not snag or get trapped.
To replace the PCB's into the case, slide the PCB's gently into the case aligning the boards with the
appropriate slots. Ensure that the fibre do not snag or get trapped.
Safety
AMG Optical Fibre Products use Class 1 laser systems in accordance with EN 60825-2:2000.
It is always advisable to follow good practice when working with optical fibre systems. This includes:

Do not stare with unprotected eyes or with any unapproved collimating device at fibre
ends or connector faces, or point them at other people.

Use only approved filtered or attenuating viewing aids
For other safety issues and advice on good practice associated with optical fibre systems, please see
EN 60825-2:2000 or your local safety officer.
Maintenance and Repair
There are no user serviceable parts within AMG products. See unit data sheet for full specification.
In case of problem or failure, please call your local support centre or contact: AMG Systems Ltd. at
3 The Omega Centre, Stratton Business Park, Biggleswade, Beds., SG18 8QB, UK.
Phone
Technical Support
Email
+44 (0) 1767 600 777
+44 (0) 1767 604 491
[email protected]
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page 7 of 8
AMG4643-SF Instruction Sheet
D16596-03.doc
This page is intentionally blank.
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page 8 of 8
AMG4643-SF Instruction Sheet
D16596-03.doc

advertisement

Key Features

  • 4 Video Channels
  • 1 Data Channel
  • Multimode Fibre
  • Point-to-Point
  • RS232/RS422/RS485

Frequently Answers and Questions

What is the maximum transmission distance for this device?
The maximum distance is limited by the Multimode optical fibre bandwidth, typically 2km. However, successful operation may be possible over longer distances, but it is recommended to test the optical fibre for distances greater than 2km.
Can I use this device with different receive units?
The AMG4643-SF is specifically designed to work with the AMG4644-SF or the rackmount equivalent AMG4644R-SF receive unit in a point-to-point configuration.
What is the power requirement for the AMG4643-SF?
The AMG4643-SF is designed to be powered using an AMG2003 standalone power supply with a voltage range of 13.5 to 18.0 Volts DC. The maximum power consumption is 5 Watts.

Related manuals

Download PDF

advertisement