Reer SR ZERO A Installation, Use And Maintenance Manual
The Reer SR ZERO A is a safety relay expansion module designed to connect machine safety circuits with 2 OSSD output devices, such as photoelectric light curtains, laser scanners, and RFID sensors. It is specifically designed for use with ReeR light curtains from the Admiral AX (category 4), Vision VX and Vision VXL/MXL (category 2) series, EOS, Magnus RFID sensor and ReeR laser scanner. This module helps ensure safe operation by monitoring the safety inputs and triggering the safety outputs to shut down the machine in case of a safety hazard.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Safety Relay Module 8541408 - 17/05/2021 Rev.0 1 English (Original instructions) Installation use and maintenance SAFETY RELAY SR ZERO A SAFETY RELAY SR ZERO A INSTALLATION USE AND MAINTENANCE TABLE OF CONTENTS OVERVIEW ........................................................................................................................................ 3 INSTALLATION AND ELECTRICAL CONNECTIONS ................................................................ 4 INSTRUCTIONS CONCERNING CONNECTION CABLES. ...................................................................... 4 PINOUT ....................................................................................................................................................... 5 CHECKLIST AFTER INSTALLATION ......................................................................................................... 5 CHARACTERISTICS OF THE OUTPUT CIRCUIT ...................................................................................... 9 STATUS INDICATORS ..................................................................................................................... 9 TECHNICAL DATA ........................................................................................................................ 10 DIMENSIONS ............................................................................................................................................ 11 English INDICATIONS AND INFORMATION FOR ENVIRONMENTAL PROTECTION ................. 12 WARRANTY.................................................................................................................................... 13 EC DECLARATION OF CONFORMITY ...................................................................................... 14 2 8541408 - 17/05/2021 Rev.0 SAFETY RELAY SR ZERO A OVERVIEW This symbol indicates an important personal safety warning. Failure to comply with the warning may result in very high risk for exposed personnel. ➔ This symbol indicates an important instruction. The SR ZERO A is a safety relays expansion used to connect the machine safety circuit to 2 OSSD output devices i.e.: • photoelectric light curtain • laser scanner • RFID sensor See details below about light curtain models, wiring, etc. When deciding on the safety category to be adopted, carefully consider the risks analysis of English the machine. The module has been designed in particular for the ReeR light curtains of the Admiral AX (category 4), Vision VX and Vision VXL/MXL (category 2) series, EOS, Magnus RFID sensor and ReeR laser scanner. Consult ReeR before using the interface with other light curtain models or safety devices. For safe use of the device, it is essential to read and understand the contents of this handbook. Failure to comply with the prescriptions indicated in this notice may result in very high risks for the operating personnel of the protected machine. 8541408 - 17/05/2021 Rev.0 3 SAFETY RELAY SR ZERO A INSTALLATION AND ELECTRICAL CONNECTIONS SR ZERO A is provided with terminal blocks for the electrical connections. The unit provides 16 terminals. ➔ Terminal tightening torque: 5...7lb-in (0,6...0,7 Nm). Install SR ZERO A in an enclosure with a protection class of at least IP54. Connect the safety relay module when it is not powered. The supply voltage to the units must be 24 20% VDC; PELV (in compliance with the standard EN 60204-1 (Chapter 6.4)). Do not use the SR ZERO A to supply external devices. The same ground connection (0VDC) must be used for all system components. Figure 1 INSTRUCTIONS CONCERNING CONNECTION CABLES. ➔ Wire size range: AWG 12...30, (solid/stranded) (UL). ➔ Use 60/75°C copper (Cu) conductor only. ➔ We recommend the use of separate power supplies for the safety relay and for other English electrical power equipment (electric motors, inverters, frequency converters) or other sources of disturbance. ➔ Cables used for connections longer than 50m must have a cross-section of at least 1mm2 (AWG16). ➔ The path of the connection cables between the safety relay and the sensors, the connection referring to the feedback contact must be different from that of other power cables. 4 8541408 - 17/05/2021 Rev.0 SAFETY RELAY SR ZERO A PINOUT TERMINAL NUMBER 1 - TYPE OF SIGNAL - 2 - - Not used 3 - - Not used 4 0VDC - Power Supply 0VDC 5 INPUT1 Input Safety input 1 6 INPUT2 Input Safety input 2 7 K1 K2 FBK IN Input Feedback K1 K2 Input 8 K1 K2 FBK OUT Output Feedback K1 K2 Output 9 - - Not used 10 - - Not used 11 B NO1 Output Safety relay B, contact 1 (N.O.) 12 B NO2 Output Safety relay B, contact 2 (N.O.) 13 - - Not used 14 - - Not used 15 A NO1 Output Safety relay A, contact 1 (N.O.) 16 A NO2 Output Safety relay A, contact 2 (N.O.) SIGNAL NAME DESCRIPTION Not used Table 1 CHECKLIST AFTER INSTALLATION To guarantee the system perfect operation perform the following checks at start up and at least every year: OPERATION / CONTROL COMPLETE ❒ 2. Verify that all the cables are correctly inserted and the terminal blocks well screwed. ❒ 3. Verify that the led (indicator) lights on correctly. ❒ 4. Verify the positioning of all the sensors connected to SR ZERO A. ❒ English 1. Verify the correct fixing of SR ZERO A to the Omega rail. 8541408 - 17/05/2021 Rev.0 5 SAFETY RELAY SR ZERO A Example of connection of the SR ZERO A module with safety light curtain SAFEGATE S (low range operation) Figure 2 Example of connection of the SR ZERO A module with AX / VX / VXL safety light curtain in AUTOMATIC operation mode English Figure 3 6 8541408 - 17/05/2021 Rev.0 SAFETY RELAY SR ZERO A Example of connection of the SR ZERO A module with AX / VX / VXL safety light curtain in MANUAL operation mode Figure 4 Example of connection of the SR ZERO A module with MXL safety light curtain in AUTOMATIC operation mode English Figure 5 8541408 - 17/05/2021 Rev.0 7 SAFETY RELAY SR ZERO A Example of connection of the SR ZERO A module with MXL safety light curtain in MANUAL operation mode Figure 6 Example of connection of the SR ZERO A module with EOS4X safety light curtain in AUTOMATIC operation mode English Figure 7 ➔ Further details regarding connections can be found on each curtain technical manual. 8 8541408 - 17/05/2021 Rev.0 SAFETY RELAY SR ZERO A CHARACTERISTICS OF THE OUTPUT CIRCUIT For the output circuit, the safety relay uses two guided contact safety relays. These relays are rated by the manufacturer for voltage and current values above those indicated in the technical data; however, to assure correct insulation and to avoid damage or premature aging, protect each output line with an appropriate fuse (depending on the load). Check that load characteristics comply with the indications given in the table below. Minimum switching voltage 18 VDC Minimum switching current 20 mA Maximum switching voltage 250 VAC Maximum switching current 6 A (AC) / 6 A (DC) STATUS INDICATORS LED COLOR IN Green STATUS/COLOR CONDITION ON ON with input activated OFF OFF with input not activated Table 2 English Figure 8 8541408 - 17/05/2021 Rev.0 9 SAFETY RELAY SR ZERO A TECHNICAL DATA SAFETY DATA VALUE SIL 3 SILCL 3 Cat.4 20 years cULus, TÜV Safety level Device lifetime Certifications Load 2A@230Vac 0,5A@24VDC STANDARD EN 61508:2010 EN 62061:2005 / A2:2015 EN ISO 13849-1: 2015 EN ISO 13849-1: 2015 Number of Commutations PFHd * DCavg # MTTFd # (years) PL # CCF # 1 every 30s 1 every min 1 every hour 1 every day 1 every 30s 1 every min 1 every hour 1 every day 1,71E-07 8,74E-08 4,99E-09 3,68E-09 3,40E-07 1,71E-07 6,39E-09 3,77E-09 98,94% 98,88% 92,16% 45,25% 98,97% 98,94% 95,46% 62,11% 27,04 54,05 3022,39 23745,23 13,52 27,04 1565,28 16296,27 d e e e d d e e 80% 80% 80% 80% 80% 80% 80% 80% * EN 61508:2010, EN 62061:2005/A2:2015; # EN ISO 13849-1: 2015 ELECTRICAL PARAMETERS Power supply Rated impulse between PELV and relay contacts Power requirement INPUT DATA Inputs number Number of EDM input OUTPUT DATA Number of safety output Type Max switching voltage Max switching current Max switching power Max Response time Mechanical service life Electrical service life AC1 at 360 switchings/h CONNECTIONS / OPERATION English Connections Status indicator Max. length of connections Operating temperature Max surrounding air temperature Storage temperature Relative humidity Maximum operating altitude Vibration resistance (CEI EN 60068-2-6:2009) Bump resistance (CEI EN 60068-2-27:2012) ENCLOSURE DATA Description Enclosure protection rating Terminal block protection rating Fastening Dimensions (h x w x d) Weight 10 VALUE 24 20% VDC; PELV 6 kV 1,5 W max 2 internal coil relays 1 NC contact 2 N.O. contacts Relays with forced guided contacts 250VAC , 125 VDC, Overvoltage Category III 6A (AC), 6A (DC) 1500VA, 180W (85W if load voltage >30 VDC) 20ms 10 x 10E6 > 10E5 16 Terminal blocks with protection against reversal of polarity Input status LED 100m -30...55°C 55°C -30...70°C 10%...95% 2000m +/- 1.5 mm 9...200 Hz 15 g (6 ms half-sine) VALUE Electronic housing 16 pole, with locking latch mounting IP 20 IP 2X Fast attachment to rail according to CEI EN 60715 99mm x 22,5mm x 113,5mm 150g 8541408 - 17/05/2021 Rev.0 SAFETY RELAY SR ZERO A (All dimensions are expressed in mm DIMENSIONS English Figure 9 8541408 - 17/05/2021 Rev.0 11 SAFETY RELAY SR ZERO A INDICATIONS AND INFORMATION FOR ENVIRONMENTAL PROTECTION Dispose of the product in an eco-compatible manner and in accordance with national legislation. For Countries in the European Union: Pursuant to the Directive no. 2012/19/EU on waste electrical and electronic equipment (WEEE). The crossed out wheelie-bin symbol on the equipment or its packaging means that when the product reaches the end of its useful life it must be collected separately from other waste. Proper separate collection of the discarded equipment for later environment-friendly recycling, processing, and disposal, helps to avoid any negative impact on the environment and health and encourages re-use and recycling of the materials the equipment is made of. In each individual Member State of the European Union this product is required to be disposed of in accordance with Directive 2012/19/EU as implemented in the Member State where the product is disposed of. English For further information please contact ReeR or your local dealer. 12 8541408 - 17/05/2021 Rev.0 SAFETY RELAY SR ZERO A WARRANTY REER warrants that each SR ZERO A unit in new ex-factory condition, in conditions of normal use, is free of defects in the materials and of manufacturing defects for a period of 12 (twelve) months. In this period, REER undertakes to eliminate any faults in the product through repair or replacement of the faulty parts, completely free of charge as regards material and labor. However, REER reserves the right to replace the entire faulty appliance with another equivalent appliance or with the same characteristics instead of repairing this. Validity of this warranty is regulated by the following conditions: • • • • The user must inform REER of the fault within twelve months from the date of delivery of the product. The appliance and its components must be in the conditions in which they were delivered by REER. The serial numbers must be clearly legible. The fault or defect has not been caused directly or indirectly by: o Improper use; o Non-compliance with instructions for use; o Carelessness, inexperience, incorrect maintenance; o Repairs, modifications, adaptations not carried out by REER personnel, tampering, etc.; o Accidents or impacts (also due to transportation or causes of force majeure); o Other causes not to be ascribed to REER. Repairs will be carried out at the REER laboratories to which the material must be delivered or dispatched: transport risks and the risks of any damage or loss of the material during shipment are the responsibility of the user. All products and components replaced become the property of REER. REER does not recognize any other warranties or rights except for those specifically described above; therefore, no claims for damages may be submitted for expenses, interruption of business or other factors or circumstances in any way related to failure of the product or of one of its parts. English Precise, complete compliance with all the rules, instructions and prohibitions indicated in this handbook is an essential requirement for correct functioning of the safety relay. REER s.p.a. therefore declines any responsibility for all and anything resulting from failure to comply, even partially, with such indications. Characteristics subject to change without notice. • Total or partial reproduction is forbidden without the prior authorization of REER. 8541408 - 17/05/2021 Rev.0 13 SAFETY RELAY SR ZERO A English EC DECLARATION OF CONFORMITY 14 8541408 - 17/05/2021 Rev.0 English SAFETY RELAY SR ZERO A All REER product manuals are available at URL https://www.reersafety.com/it/en/download/manuals 8541408 - 17/05/2021 Rev.0 15
advertisement
Key Features
- 2 OSSD Outputs
- Safety Inputs
- ReeR Light Curtain Compatibility
- SIL 3 Safety Level
- Category 4/2
- Modular Design
- LED Status Indicators
- IP20 Enclosure