Dahua ASC2102B-T User Manual
The Dahua ASC2102B-T is a two-door slave access controller designed for use with a master controller. Suitable for banks, prisons, and other secure locations, it supports up to 4 card readers and provides features like alarm integration, black-white list setup, and offline record storage for up to 30,000 events. The device is equipped with CAN bus communication for connection to a master controller, and it allows for external extension modules to be added.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
19
Two door two-way Slave Access Controller User’s Manual V1.0.0 Legal Statement Trademark VGA is the trademark of IBM. Windows logo and Windows are trademarks or registered trademarks of Microsoft. Other trademarks and company names mentioned are the properties of their respective owners. About this Document This document is for reference only. Please refer to the actual product for more details. This document serves as a reference for multiple types of products, whose specific operations won’t be enumerated. Please operate according to actual products. The user shall undertake any losses resulting from violation of guidance in the document. In case that PDF document cannot be opened, please upgrade the reading tool to the latest version or use other mainstream reading tools. This company reserves rights to revise any information in the document anytime; and the revised contents will be added to the new version without prior announcement. Some functions of the products may be slightly different before and after revision. The document may include technically inaccurate contents, inconsistencies with product functions and operations, or misprint. Final explanations of the company shall prevail. I Preface Overview This document elaborates on structure, installation, interface and wiring of two-door slave access controller. Symbol Definition The following symbols may appear in this document. And their meanings are as follows: Symbol Note It indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. It indicates a moderate or low level of potential danger which, if not avoided, could result in minor or moderate injury. It indicates a potential risk that, if ignored, could result in damage to device, loss of data, degraded performance, or unpredictable results. It means electrostatic-sensitive device. It means high-voltage danger. It means intensive laser radiation. It means that it can help you to solve some problems or save your time. It means the additional information, which is to emphasis or supplement. II Important Safeguards and Warnings The following description is the correct application method of the device. Please read the manual carefully before use, in order to prevent danger and property loss. Strictly conform to the manual during application and keep it properly after reading. Operating Requirement Please don’t place and install the device in an area exposed to direct sunlight or near heat generating device. Please don’t install the device in a humid, dusty or fuliginous area. Please keep its horizontal installation, or install it at stable places, and prevent it from falling. Please don’t drip or splash liquids onto the device; don’t put on the device anything filled with liquids, in order to prevent liquids from flowing into the device. Please install the device at well-ventilated places; don’t block its ventilation opening. Use the device only within rated input and output range. Please don’t dismantle the device arbitrarily. Please transport, use and store the device within allowed humidity and temperature range. Power Requirement Please make sure to use batteries according to requirements; otherwise, it may result in fire, explosion or burning risks of batteries! To replace batteries, only the same type of batteries can be used! The product shall use electric cables (power cables) recommended by this area, which shall be used within its rated specification! Please use standard power adapter matched with the device. Otherwise, the user shall undertake resulting personnel injury or device damage. Please use power supply that meets SELV (safety extra low voltage) requirements, and supply power with rated voltage that conforms to Limited Power Source in IEC60950-1. For specific power supply requirements, please refer to device labels. Products with category I structure shall be connected to grid power output socket, which is equipped with protective grounding. Appliance coupler is a disconnecting device. During normal use, please keep an angle that facilitates operation. III Table of Contents Legal Statement ......................................................................................................................................... I Preface ....................................................................................................................................................... II Important Safeguards and Warnings .................................................................................................... III 1 Overview .............................................................................................................................................. 1 2 Packing List ......................................................................................................................................... 2 3 Installation Guide................................................................................................................................ 3 3.1 System Structure........................................................................................................................... 3 3.2 External Dimension ....................................................................................................................... 3 3.3 Device Installation ......................................................................................................................... 4 3.4 Disassembly .................................................................................................................................. 5 3.5 Wiring Description ......................................................................................................................... 6 3.5.1 Wiring Description of CAN Bus........................................................................................... 7 3.5.2 Wiring Description of Exit Button/Door Sensor .................................................................. 7 3.5.3 Wiring Description of External Alarm Input ......................................................................... 8 3.5.4 Wiring Description of External Alarm Output ...................................................................... 8 3.5.5 Wiring Description of Lock .................................................................................................. 9 3.5.6 Wiring Description of Internal Alarm Output ..................................................................... 10 3.5.7 Wiring Description of Reader............................................................................................ 10 3.6 DIP Switch ....................................................................................................................................11 3.7 Reboot ......................................................................................................................................... 12 4 Technical Parameters ....................................................................................................................... 13 IV 1 Overview As a slave controller of access master controller, two-door slave access controller is matched with access master controller and is widely used in banks, prisons and safe places. Its rich functions are as follows: Adopt sliding rail type and lock type installation, convenient installation and maintenance. Integrate alarm and fire alarm. Support 4 sets of card readers. Support 9 groups of signal input (exit button *2, door sensor *2 and intrusion alarm *5). Support 5 groups of control output (electric lock *2 and alarm output *3). With RS485 port, it may extend to connect lift control module, alarm or household control module. Support CAN bus and connect master controller. FLASH storage capacity is 16M (which may extend to 32M), max supports 20,000 card holders and 30,000 offline records. Support illegal intrusion alarm, exit overtime alarm, duress card alarm and duress code setup. Also support black-white list and patrol card setup. Data storage during outage, built-in RTC (support DST), online upgrading. If this product needs to connect external power supply, please use 12V 0.5A adapter and ensure that working temperature shall not exceed -5℃~+55℃. 1 2 Packing List Before installation, please check according to Table 2-1. No. Name Quantity 1 Access controller 1 2 Installation positioning drawing 1 3 Accessory kit (screw, expansion pipe and wiring terminal) 1 4 Quick start guide 1 5 Certificate of qualification 1 Table 2-1 2 3 Installation Guide 3.1 System Structure System structure of two-door slave access controller, door lock and reader is shown in Figure 3-1. Figure 3-1 3.2 External Dimension Its appearance and dimension is shown in Figure 3-2 and Figure 3-3. The unit is mm. 3 Figure 3-2 Figure 3-3 3.3 Device Installation There are two installation modes. Mode 1: fix the whole device onto the wall with screws. Mode 2: install U-shaped guide rail, and hang the whole device onto the wall (U-shaped guide rail is a self-bought fitting). Mode 1 Installation diagram is shown in Figure 3-4. 4 Figure 3-4 Mode 2 Installation diagram is shown in Figure 3-5. Figure 3-5 Step 1 Fix the U-shaped guide rail onto the wall with screws. Step 2 Buckle the upper rear part of the device into upper groove of U-shaped guide rail. Step 3 Push the snap joint at the bottom of the device upwards. The installation is completed when you hear the fitting sound. 3.4 Disassembly If the device is installed with mode 2, please disassemble it according to Figure 3-6. Align a screwdriver with the snap joint, press it down and the snap joint will pop up, so the 5 whole device can be disassembled smoothly. Figure 3-6 3.5 Wiring Description Device wiring diagram is shown in Figure 3-7. Figure 3-7 Interfaces are described in Table 3-1. 6 No. Interface Description No. Interface Description 1 CAN bus 9 Not available at present 2 External extension module 10 Entry reader of door 1 3 Door sensor and exit button 11 Exit reader of door 1 4 External alarm input 12 Entry reader of door 2 5 External alarm output 13 Exit reader of door 2 6 Lock control output 14 Reboot 7 Internal alarm output 15 DC 12V power interface 8 Address code/transmission rate Table 3-1 Indicator lights are described in Table 3-2. No. Description 16 Lock status indicator 17 18 Alarm status indicator 19 20 Power indicator Table 3-2 3.5.1 Wiring Description of CAN Bus Wiring terminals of CAN bus are described in Table 3-3. Interface Wiring Terminal CANL CAN bus input CANH CAN bus Description CANL CAN bus output CANH Table 3-3 3.5.2 Wiring Description of Exit Button/Door Sensor Corresponding wiring terminals of exit button and door sensor are shown in Figure 3-8. Please refer to Table 3-4 for descriptions of wiring terminals. Figure 3-8 Interface Exit button+ door Wiring Terminal Description GND Shared by exit button of door 1 and door 7 Interface Wiring Terminal sensor Description sensor input of door 1 PUSH1 Exit button of door 1 SR1 Door sensor input of door 1 PUSH2 Exit button of door 2 SR2 Door sensor input of door 2 GND Shared by exit button of door 2 and door sensor input of door 2 Table 3-4 3.5.3 Wiring Description of External Alarm Input External alarm input connection is shown in Figure 3-9. Please refer to Table 3-4 for descriptions of wiring terminals. Figure 3-9 Interface External alarm input Wiring Terminal Description ALM1 Alarm input interface 1 ALM2 Alarm input interface 2 ALM3 Alarm input interface 3 ALM4 Alarm input interface 4 ALM5 Alarm input interface 5 (reserved) GND Shared by alarm input interface 1, 2, 3, 4 and 5 External alarm input interfaces are able to connect smoke detector and IR detector etc.. Table 3-5 3.5.4 Wiring Description of External Alarm Output There are two connection modes of external alarm output, depending on alarm device. For example, IPC can use Mode 1, whereas audible and visual siren can use Mode 2, as shown in Figure 3-10 and Figure 3-11. Please refer to Table 3-6 for descriptions about wiring terminals. 8 Figure 3-10 Figure 3-11 Interface External output alarm Wiring Terminal Description NO External alarm output interfaces are able to connect audible and visual sirens. COM Table 3-6 3.5.5 Wiring Description of Lock Support 2 groups of lock control outputs; serial numbers after the terminals represent corresponding doors. Please choose a proper connection mode according to lock type, as shown in Figure 3-12, Figure 3-13 and Figure 3-14. Please refer to Table 3-7 for descriptions of wiring terminals. Figure 3-12 Figure 3-13 9 Figure 3-14 Interface Wiring Terminal Description NC1 COM1 Lock control output Lock control of door 1 NO1 NC2 COM2 Lock control of door 2 NO2 Table 3-7 3.5.6 Wiring Description of Internal Alarm Output Corresponding wiring terminals of internal alarm control output are shown in Table 3-8. Interface Wiring Terminal Description NC1 Intrusion, overtime and vandal-proof alarm output of door 1. Output time lasts for 15s. COM1 Internal alarm control output NO1 NC2 Intrusion, overtime and vandal-proof alarm output of door 2. Output time lasts for 15s. COM2 NO42 Table 3-8 3.5.7 Wiring Description of Reader 1 door only supports to connect one type of reader—485 or Wiegand. Please refer to Table 3-9 for descriptions of wiring terminals corresponding to readers. Take Door 1 for example, and other readers are the same as door 1. Please refer to Table 3-10 for descriptions of video cable specification and length. Interface Entry Reader of Door 1 Wiring Terminal Cable Color 485+ Purple 485- Yellow LED Brown D0 Green D1 White CASE Blue GND Black Description 485 reader Wiegand reader Reader power supply 10 Interface Wiring Terminal Cable Color 12V Red Description Table 3-9 Reader Type Connection Mode Length 485 Reader CAT5e network cable, 485 connection 100m Wiegand Reader CAT5e network cable, Wiegand connection 30m Table 3-10 3.6 DIP Switch Set device number and speed with DIP switch. DIP switch is shown in Figure 3-15. Please refer to Function No. Description Set device number with binary system. The left is the lowest order. For example: Device Number 1~5 Binary representation 00110 corresponds to 6 in decimal system. Set the speed. All of them are at the bottom , transmission speed is 50kb/s. Only digit 6 is at ON position Speed 6~8 , transmission speed is 80kb/s. Only digit 7 is at ON position , transmission speed is 100kb/s. Digits 6 and 7 are at ON position , transmission speed is 125kb/s. 11 Table 3-11 for details. the switch is at ON position, meaning 1. the switch is at the bottom, meaning 0. Figure 3-15 Function No. Description Set device number with binary system. The left is the lowest order. For example: Device Number 1~5 Binary representation 00110 corresponds to 6 in decimal system. Set the speed. All of them are at the bottom , transmission speed is 50kb/s. Only digit 6 is at ON position Speed 6~8 , transmission speed is 80kb/s. Only digit 7 is at ON position , transmission speed is 100kb/s. Digits 6 and 7 are at ON position , transmission speed is 125kb/s. Table 3-11 12 3.7 Reboot Insert a needle into RESET hole, and long press the reboot controller. 13 4 Technical Parameters Parameter Specification Processor 32-bit ARM processor Storage Capacity 16M Max User 20,000 Max Record 30,000 Communication Port of Reader Wiegand,RS485 Communication Port CAN Quantity of Connected Reader 4 groups Working Power Rated power 10V~15V DC, rated current 0.75A Real-time Monitoring Support Fire Alarm Linkage Support Vandal-proof Alarm Support Illegal Intrusion Alarm Support Unlock Overtime Alarm Support Duress Card Setup Support DST and Time Sync Support Online Upgrading Support 14
advertisement
Key Features
- Slave Access Controller
- Two Door Control
- CAN Bus Communication
- Alarm Integration
- Extensive User & Record Capacity
- External Module Support
- Black-White List Setup
- Offline Record Storage
Frequently Answers and Questions
What is the maximum number of card readers supported by the ASC2102B-T?
It supports up to 4 sets of card readers.
Does the ASC2102B-T have offline record storage?
Yes, it has FLASH storage with a capacity of 16M, capable of storing up to 30,000 offline records.
What types of alarm integration does the ASC2102B-T support?
It supports intrusion alarm, exit overtime alarm, duress card alarm, and duress code setup.