- KUSSMAUL
- 023-4400-0
- Instruction manual
- 5 Pages
KUSSMAUL 023-4400-0 Instruction Manual
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
5
INSTRUCTION MANUAL ENGINE MONITOR VOTT MODEL: 023-4400-0 3 YEAR WARRANTY INTRODUCTION The VOTT meter is an ideal engine monitor, which displays data via the J1939 CAN Bus. The meter utilizes a large LCD screen to simultaneously display DC volts, oil pressure, temperature and tachometer. It provides accurate digital metering and user programmable alarms. When alarm thresholds are exceeded, the built-in 85 dB alarm will sound and the affected display reading will change to RED for the out-of-limit condition. Additionally, a new feature always for user selectable baud-rate, 50k – 1000k bits/sec. The meter is waterproof and rugged with a large color LCD display screen. The screen read-out is divided into 4 display sections allowing the operator quick, and accurate assessment of engine conditions. DC volts are displayed from 9.5 – 33.0 VDC. Oil pressure is displayed from 0 – 99 PSI. Additionally engine temp and RPM are displayed, 100 – 250 F and 0000 – 9999 RPM, respectively. The meter is powered by 12-24 VDC. Four levels of backlighting can be selected for optimal performance. All set-up, calibration and alarm values are saved to non-volatile memory. The system is complete with all necessary mounting hardware. The large LCD display draws only 0.08 amps at full brightness and only 0.02 in sleep mode. The meter comes with a 3 year warranty. 170 Cherry Avenue West Sayville, NY 11796 www.kussmaul.com File: VOTT_023-4400-0 Rev: B Revised By: PSS/JRN Date: 01-17-2017 Ph: 800-346-0857 Fax: 631-567-5826 [email protected] 1 I. WIRING III. MENU NAVIGATION The VOTT comes with a 33 inch length six conductor cable with a Deutsch Connector #DT04_ 6P attached. The VOTT will operate from 9.5 to 33.0 VDC input. It displays data via J1939 CAN Bus. Meter Deutsch connector pin ID is . When the instrument is powered up it displays the “Main” page. The “Main” page displays: ENGINE RPM,OIL PSI, ENGINE TEMP F (OR C) and BATT VOLTS. Values are displayed in GREEN if within acceptable alarm set limits or RED if out of limits condition exists. Signal Wire Color 1 2 3 4 5 +9.5- 33.0 VDC Power/Signal Ground J1939+ J1939 External buzzer 12 VDC alarm output + External buzzer 12 VDC alarm output - Red Black Yellow Green White 53 ENGINE TEMP F BATT VOLTS 13.8 From MAIN PAGE display: • Pressing the p key for ½ second (longer than a quick press but shorter than 2 seconds) will cause a white ALARM bell symbol to be displayed and enable the alarms. • Pressing the q key for ½ second (longer than a quick press but shorter than 2 seconds) will disable the alarms and remove the white alarm bell symbol. Blue ENGINE RPM The VOTT requires a 2-1/8” diameter round hole for mounting. The meter comes with a aluminum U shaped mounting bracket and #8-32 nuts and lock washers to secure bracket. See Figure 1. (FINGER TIGHTEN ONLY, DO NOT USE TOOLS) Spacing Nut (x2) 2971 125 II. MOUNTING 2-1/8” (55mm) Hole OIL PSI ENGINE RPM Pin 6 1. Main Page Clamping Nut (x2) Lock Washer (x2) OIL PSI 2971 53 ENGINE TEMP F BATT VOLTS 125 13.8 ENGINE RPM 2971 ENGINE TEMP F 125 x 53 OIL PSI BATT VOLTS 13.8 • Press the “+” key momentarily while an alarm condition exists will silence the audible and external alarm as indicating by Red “X” • Pressing the + key for ½ second (longer than a quick press but shorter than 2 seconds) will increment the backlight level through four different intensities. Mounting Bracket Bulkhead Gasket - Pre-Installed on Rear of Panel 170 Cherry Avenue West Sayville, NY 11796 www.kussmaul.com Ph: 800-346-0857 Fax: 631-567-5826 [email protected] 2 2. Menu Tree: II. SET UP: ACCESS CODE USE DEG C/BARS ( or use DEG F/PSI) RESET MIN/MAX VALUES (see Details page) <-- BACK Press * A) Secured Access Pages ACCESS CODE While in the Main page or Generator Hours page, a Quick press of the * key brings up the Security Access page and a default number 5000 is displayed in the ACCESS CODE box. USE DEG C/BARS RESET MIN/MAX VALUES SET CAN BUS SPEED < - - BACK About Down Accept Up Quit -ACCESS CODE SETTING Use the p and q keys to scroll to the correct access code and press “ACCEPT” to enter that number (default ACCESS CODE is 1234). The longer you hold down the p or q key, the faster the scrolling of numbers. False entry results in Main Page being displayed. Entry of correct access code unlocks the instrument and brings up the following menu: Alarms B) Category: I.ALARMS II.SETUP III.DETAILS IV.ABOUT The ACCESS CODE is required to access alarm settings, and instrument setup menus. Set the ACCESS CODE to a number from 0000 to 9999 by using the p and q keys then press the + key to accept. The factory default is set to 1234. For S/W: 2.1 or higher default is set to 4321. Set Up Details About Setup Details About Down Accept I. ALARMS Menu: BATT VOLTS HI BATT VOLTS LO OIL PRESSURE HI OIL PRESSURE LO ENGINE TEMP. HI ENGINE RPM HI <-- BACK If no key has been pressed for 60 seconds from any of the menus or submenus, the instrument will revert to displaying the Main Page. Up Quit Alarms Set UpBatt. Volts HI -SET CAN BUS SPEED DetailsBatt. Volts LO About Oil Pressure HI Setup Oil Pressure LO Details Engine TEMP HI About Engine RPM HI CHANGE VALUE 116.0 ACCESS CODE DC VOLTS USE DEG C/BARS RESET MIN/MAX VALUES <-- BACK Down Accept If the ACCESS CODE is ever forgotten, the instrument can be reset back to factory default. Reset to “Factory Defaults” by pressing and holding the p and q keys while applying DC power. Answer “Yes” by pressing key labeled “Yes”. This will reset pasword to 1234. Caution: Resetting to factory default will reset all alarm settings as well. SET CAN BUS SPEED Up Quit < - - BACK CHANGE VALUE 10500 BIT RATE KB/S About Alarm Ranges: Engine RPM: 0000 - 9999 is set to 1300 (whole numbers only) Oil Pressure: Low/High settable to 00 - 99 (whole numbers only) Engine Temp: High settable to 100 - 250 Battery Volts: Low/High settable to 9.0 - 33.0 170 Cherry Avenue West Sayville, NY 11796 www.kussmaul.com Down Accept Up Quit Serial #’s starting with the letter ‘B’ can be adjusted to various Can Bus Bit Rates: 50,125,250,500,1000 K Bits. Units are factory set to 500K. Ph: 800-346-0857 Fax: 631-567-5826 [email protected] 3 -PRESS ACCEPT The Bit Rate can be changed by accessing the SET UP category and selecting “SET CAN BUS SPEED” use Up/ Down arrows to set changes in VALUES. III. DETAILS: Displays details page. SN, Min/Max, Alarm Values, etc. IV. ABOUT: Displays splash screen, SW version, HW version and copyright information. SPECIFICATIONS Power Supply: 9.50 to 33.00 VDC, @ 80mA Operating Temperature: 32° to 122° F (0° to 50° C) Size: 4.3” x 4.3” x 3.5” deep (110 x 110 x 89 mm) Display Data: Engine RPM: 0000-9999 ( or as provided by J1939) On screen title “ENGINE RPM” Oil Pressure: 0199 PSI (or as provided by J1939). On screen title “OIL LSI” (factory default).User selectable for Millibars or European standard. On Screen “MBRS”. Engine Temp:100-250° F ( or as provided by J1939) On screen title “ ENGINE TEMP F” (factory default0. User selectable for Centigrade, on screen title ”ENGINE TEMP C” Battery Volts: 9.5 - 33.0 On screen title ”BATT VOLTS”. Displays “COMM LOSS” & red dashes with loss of J1939 DATA. No alarm on COMM LOSS. Accuracy: Battery Volts: As provided by J1939 Engine RPM : As provided by J1939 Engine Temperature: As provided by J1939 Oil Pressure: As provided by J1939 Alarms: Engine RPM, Low/High Oil Pressure, High Engine Temp. and Low/High Battery Volts Alarm Output: 12 VDC, 50 mA max. Kussmaul Electronics VOTT ENGINE MONITOR S/W= 20 H/W= XX www.kussmaul.com COPR. 2011,2016 Cruzpro LTD. Back Back Back Quit Additional Information: • Low Oil Pressure only updated if Rpm>100 (ie: engine running) • Battery Voltage limited to 99.9 (only 3 digits for display) • Oil Pressure limited to 99 PSI (only 2 digits for display) • Engine Temperature 32 deg F (0 deg C) minimum (avoid negative numbers when in Deg C) • MaxRpm only updated if Rpm > MaxRpm+10 (help prevent exceeding max number of Flash writes) • “LOST COMM” message displayed if no J1939 data received for 10 or more seconds. Restore display on valid data or any key • A press of any button activates/restarts 5 minute alarm “silence” timer • Don’t allow INSTRUMENT hours to increment in Sleep mode 170 Cherry Avenue West Sayville, NY 11796 www.kussmaul.com Ph: 800-346-0857 Fax: 631-567-5826 [email protected] 4 INSTALLATION RECORD DATE INSTALLED _______________________________________________________ INSTALLED BY _________________________________________________________ VEHICLE IDENTIFICATION _______________________________________________ VEHICLE OWNER _______________________________________________________ WARRANTY POLICY All products of Kussmaul Electronics Company Inc. are warranted to be free of defects of material or workmanship. Liability is limited to repairing or replacing at our factory, without charge, any material or defects which become apparent in normal use within 3 years from the date the equipment was shipped. Equipment is to be returned, shipping charges prepaid and will be returned, after repair, shipping charges paid. Kussmaul Electronics Company, Inc. shall have no liability for damages of any kind to associated equipment arising from the installation and/or use of the Kussmaul Electronics Company, Inc. products. The purchaser, by the acceptance of the equipment, assumes all liability for any damages which may result from its installation, use or misuse, by the purchaser, his or its employees or others. 170 Cherry Avenue West Sayville, NY 11796 www.kussmaul.com Ph: 800-346-0857 Fax: 631-567-5826 [email protected] 5
advertisement