Leader Light LL STAGE CYC 6C is a powerful and versatile lighting fixture designed for stage and event applications. It offers high-quality illumination and features a DMX 512 interface for precise control. The fixture integrates a reliable AC/DC power supply and includes convenient mounting brackets for easy setup. This model excels in creating dramatic lighting effects for theatre, concerts, and other events, supporting your creative vision.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Leader Light LL STAGE CYC 6C User Manual | Manualzz
Page 1 /2
!
02.2 Product description
DMX Out
XLR-5pin
WARNING!!!
Carefully read before installing, powering or servicing. Nothing to do if
anything misunderstand! Installation can be done only by a qualified
professional in accordance with relevant local codes.
LL Stage CYC 6C
LL Stage CYC 5C
LL Stage CYC 4C
LL Stage CYC 3C
LL Stage CYC 2C
LL Stage CYC 1C
334
Additional items needed:
-- Data and power cables
-- Controller compatible with DMX 1pc.
-- Mounting accessories as necessary
Content:
01
SAFETY INFORMATION
01.1 Risk of eyes damage
01.2 Safety instructions
01.3 Fire protection
02
04
PRODUCT SPECIFICATION
02.1 Technical specification
02.2 Product description
INSTALLATION
03.1 Unpacking
03.2 Physical installation
03.3 Connection
03.4 Control data connection
03.5 DMX channels
PERMANENET USE LIMITATIONS
05
MAINTENANCE AND SERVICE
03
Made in EU
Leader Light s.r.o.
Slovakia, 20__
www.leaderlight.eu
1pc.
1pc.
AC/DC 90 – 264 V, 50/60 Hz
T max. 40° C
SN
-- LL STAGE CYC with adj. bracket
-- User manual
POWER OUT
Package includes:
POWER IN
200
Address
set-up
under cover
MADE IN SLOVAKIA
www.leaderlight.eu
343
DMX OUT
All dimensions are in millimeters
DMX IN
01.1 Risk of eyes damage
--Do not look directly into LED lamps.
--Do not look into light beam from a distance of less than 40 cm (16 inches)!
COMPLIMENTS ON YOUR PURCHASE!
DMX In
XLR-5pin
POWER
LL STAGE CYC 6C / 3C / 2C / 1C
USER MANUAL
01 SAFETY INFORMATION
WARNING - Disconnect
mains before remove cover!
LEADER LIGHT s.r.o.
M.Gorkeho 33
052 01 Spisska Nova Ves
Slovakia
www.leaderlight.eu
01.2 Safety instructions
-- Shut down power before installation or maintenance.
-- Do not modify, alter, or attempt to service the LEADER LIGHT appliance. Doing
so will void the warranty.
-- Appliance and recommended AC power supply must be installed by a qualified
professional in accordance with relevant local codes. Use only acceptable source
of AC power and frequency that complies with local biulding and electrical codes.
-- Use only the recommended voltage source.
-- Appliance always connect to earth (eltech.)!
-- Do not use or do not connect the products if the power cable, power plug or
fixtures are any way damaged, wet, or if they are overheating.
-- Before removing or installing any cover or part of appliance disconnect it from AC
power.
-- AC power supply must be protected against overvoltage and short circuits.
01.3 Fire protection
-- Follow all safety restrictions.
-- Thermostatic switches or fuses never to bypass.
-- Device never shield. Around the axis of the fitting (180°) must be maintained space
for cooling. Minimum distance from the surrounding objects must be 100mm (4 in.).
-- LEDs never direct cover with filters or other materials.
-- Allowing max. ambient temperature is 40°C (104°F).
-- Luminaries never use without mounting brackets. The housing never install
directly to the surface.
Power Out
PowerCon
Power In
PowerCon
03 INSTALLATION
03.1 Unpacking
-- Unpack carefully.
-- This is electronic equipment and should be handled carefully.
-- Damaged delivered package or if are any mechanical parts broken – it must be
claim immediately by the transport company. Photo pictures as evidence are
valuable for future claim.
03.2 Physical installation
-- Loading capacity of bearing area has to be at least 10 times the weight of all
device clusters.
-- Hairbreadth from combustible materials is 0,5m.
02 PRODUCT SPECIFICATION
03.3 Connection
02.1 Technical specification
Power connection: AC 90 – 264 V, 47 – 63 Hz In/Out PowerCon
IP: IP20
Control data: DMX 512 In/Out with XLR 5pin
Ambient temp. (Ta): Maximum 40°C
Net weight: 5kg
Installation: Surface mounting
Cooling: Active 5 dB @ 1 m
-- Respect all SAFETY INFORMATION 01!
-- Connect the ground (earth) !
-- It is not necessary to open the fixture before power supply. Power supply is
solved simple with Neutrik PowerCon connectors.
-- The fixture is equipped with auto-switching power supply that automatically
adjusts to any AC 90 – 264 V, 47 – 63 Hz.
-- Cord plug connections:
Symbol
Pin
Wire Colour
Screw (US)
L
live
brown
yellow or brass
N
ENVIRONMENTAL PROTECTION
!
neutral
blue
silver
ground (earth)
yellow/green
green
Do not throw away the appliance with the normal household waste at the end of its
life, but hand it in at an official collection point for recycling. By doing this, you help to
preserve the environment.
©MMXVI - LEADER LIGHT – All right reserved
Edition: A - 2016
Additional information on [email protected]
Page 2 /2
03.4 Control data connection
Mechanical mounting of LL STAGE CYC
--Control data cable length is specified by Norm IEC929 Annex E4.
--It is not necessary to open the fixture before connecting of DMX512 control
Mounting on stage is easy. The brackets are connect by Camlocs.
Camloc 1/4 turn fasteners
-- Safe mechanical quick release
fastener systems
-- Locking/unlocking by quarter turn
-- Hand operated
-- Service-friendly, time-saving
and cost cutting
-- Vibration-resistant
POWER IN
POWER OUT
AC/DC 90 – 264 V, 50/60 Hz
T max. 40° C
SN
Made in EU
Leader Light s.r.o.
Slovakia, 20__
www.leaderlight.eu
0°
18
!
DMX OUT
-- Pernament use limitations for heating dissipation of LL STAGE CYC - body temperature
must be less then 55°C
DMX IN
04 PERNAMENT USE LIMITATIONS FOR HEATING DISSIPATION
05 MAINTENANCE AND SERVICE
LL Stage CYC 6C
LL Stage CYC 5C
LL Stage CYC 4C
LL Stage CYC 3C
LL Stage CYC 2C
LL Stage CYC 1C
These informations are subject to change, latest data are on: www.leaderlight.eu
POWER
See the relevant Appendix!
WARNING - Disconnect
mains before remove cover!
03.5 DMX channels
MADE IN SLOVAKIA
www.leaderlight.eu
signal. Interconnections are realized by Neutrik XLR 5pin In/Out connectors.
-- Before any maintenance is necessary to carefully read all SAFETY INFORMATION 01!
-- Damages caused by inadequate cleaning or maintenance are not covered by warranty.
-- Requires periodic cleaning (dust, dirt ,...)
Procedure for maintenance:
-- Unplug mains before maintenance and at least 10 minutes cool off.
-- Appliance do not illegal open or demount.
-- Clean-up dust only from outer surface. Use vacuum or dumpy duster (warm
water)
-- Before reinstalling make sure everything is intact and dry– no wet parts!
Service:
AIMING POSSIBILITY
The fixture could be aim to wish position with
adjustable bracket.
-- Customer service provided by the manufacturer.
ACCESSORIES
Screw the BRACKET to the surface/structure at least in 4 points
©MMXVI - LEADER LIGHT – All right reserved
Edition: A - 2016
LL STAGE CYC TUBUS
LL STAGE CYC POLE OPERATION BRACKET
Additional information on [email protected]

advertisement

Key Features

  • DMX 512 control
  • AC/DC power supply
  • Adjustable bracket
  • High-power LED
  • Surface mounting
  • IP20 protection

Frequently Answers and Questions

What is the power input voltage range of the LL STAGE CYC 6C?
The LL STAGE CYC 6C accepts an AC input voltage range of 90 – 264 V.
How is the LL STAGE CYC 6C connected to the DMX control system?
The LL STAGE CYC 6C uses a standard XLR 5pin connector for DMX 512 data input and output.
What is the maximum ambient temperature that the LL STAGE CYC 6C can operate in?
The maximum ambient temperature for the LL STAGE CYC 6C is 40°C.
What type of mounting bracket does the LL STAGE CYC 6C use?
The LL STAGE CYC 6C comes with an adjustable bracket that can be mounted to a surface for secure installation.
What kind of connectors are used for power input and output on the LL STAGE CYC 6C?
The LL STAGE CYC 6C uses Neutrik PowerCon connectors for both power input and output.
Is the LL STAGE CYC 6C compatible with other DMX-controlled devices?
Yes, the LL STAGE CYC 6C is compatible with any DMX 512 control system and other DMX devices.

Related manuals

Download PDF

advertisement