Leader Light LL STAGE CYC 6C User Manual
Leader Light LL STAGE CYC 6C is a powerful and versatile lighting fixture designed for stage and event applications. It offers high-quality illumination and features a DMX 512 interface for precise control. The fixture integrates a reliable AC/DC power supply and includes convenient mounting brackets for easy setup. This model excels in creating dramatic lighting effects for theatre, concerts, and other events, supporting your creative vision.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
Page 1 /2 ! 02.2 Product description DMX Out XLR-5pin WARNING!!! Carefully read before installing, powering or servicing. Nothing to do if anything misunderstand! Installation can be done only by a qualified professional in accordance with relevant local codes. LL Stage CYC 6C LL Stage CYC 5C LL Stage CYC 4C LL Stage CYC 3C LL Stage CYC 2C LL Stage CYC 1C 334 Additional items needed: -- Data and power cables -- Controller compatible with DMX 1pc. -- Mounting accessories as necessary Content: 01 SAFETY INFORMATION 01.1 Risk of eyes damage 01.2 Safety instructions 01.3 Fire protection 02 04 PRODUCT SPECIFICATION 02.1 Technical specification 02.2 Product description INSTALLATION 03.1 Unpacking 03.2 Physical installation 03.3 Connection 03.4 Control data connection 03.5 DMX channels PERMANENET USE LIMITATIONS 05 MAINTENANCE AND SERVICE 03 Made in EU Leader Light s.r.o. Slovakia, 20__ www.leaderlight.eu 1pc. 1pc. AC/DC 90 – 264 V, 50/60 Hz T max. 40° C SN -- LL STAGE CYC with adj. bracket -- User manual POWER OUT Package includes: POWER IN 200 Address set-up under cover MADE IN SLOVAKIA www.leaderlight.eu 343 DMX OUT All dimensions are in millimeters DMX IN 01.1 Risk of eyes damage --Do not look directly into LED lamps. --Do not look into light beam from a distance of less than 40 cm (16 inches)! COMPLIMENTS ON YOUR PURCHASE! DMX In XLR-5pin POWER LL STAGE CYC 6C / 3C / 2C / 1C USER MANUAL 01 SAFETY INFORMATION WARNING - Disconnect mains before remove cover! LEADER LIGHT s.r.o. M.Gorkeho 33 052 01 Spisska Nova Ves Slovakia www.leaderlight.eu 01.2 Safety instructions -- Shut down power before installation or maintenance. -- Do not modify, alter, or attempt to service the LEADER LIGHT appliance. Doing so will void the warranty. -- Appliance and recommended AC power supply must be installed by a qualified professional in accordance with relevant local codes. Use only acceptable source of AC power and frequency that complies with local biulding and electrical codes. -- Use only the recommended voltage source. -- Appliance always connect to earth (eltech.)! -- Do not use or do not connect the products if the power cable, power plug or fixtures are any way damaged, wet, or if they are overheating. -- Before removing or installing any cover or part of appliance disconnect it from AC power. -- AC power supply must be protected against overvoltage and short circuits. 01.3 Fire protection -- Follow all safety restrictions. -- Thermostatic switches or fuses never to bypass. -- Device never shield. Around the axis of the fitting (180°) must be maintained space for cooling. Minimum distance from the surrounding objects must be 100mm (4 in.). -- LEDs never direct cover with filters or other materials. -- Allowing max. ambient temperature is 40°C (104°F). -- Luminaries never use without mounting brackets. The housing never install directly to the surface. Power Out PowerCon Power In PowerCon 03 INSTALLATION 03.1 Unpacking -- Unpack carefully. -- This is electronic equipment and should be handled carefully. -- Damaged delivered package or if are any mechanical parts broken – it must be claim immediately by the transport company. Photo pictures as evidence are valuable for future claim. 03.2 Physical installation -- Loading capacity of bearing area has to be at least 10 times the weight of all device clusters. -- Hairbreadth from combustible materials is 0,5m. 02 PRODUCT SPECIFICATION 03.3 Connection 02.1 Technical specification Power connection: AC 90 – 264 V, 47 – 63 Hz In/Out PowerCon IP: IP20 Control data: DMX 512 In/Out with XLR 5pin Ambient temp. (Ta): Maximum 40°C Net weight: 5kg Installation: Surface mounting Cooling: Active 5 dB @ 1 m -- Respect all SAFETY INFORMATION 01! -- Connect the ground (earth) ! -- It is not necessary to open the fixture before power supply. Power supply is solved simple with Neutrik PowerCon connectors. -- The fixture is equipped with auto-switching power supply that automatically adjusts to any AC 90 – 264 V, 47 – 63 Hz. -- Cord plug connections: Symbol Pin Wire Colour Screw (US) L live brown yellow or brass N ENVIRONMENTAL PROTECTION ! neutral blue silver ground (earth) yellow/green green Do not throw away the appliance with the normal household waste at the end of its life, but hand it in at an official collection point for recycling. By doing this, you help to preserve the environment. ©MMXVI - LEADER LIGHT – All right reserved Edition: A - 2016 Additional information on [email protected] Page 2 /2 03.4 Control data connection Mechanical mounting of LL STAGE CYC --Control data cable length is specified by Norm IEC929 Annex E4. --It is not necessary to open the fixture before connecting of DMX512 control Mounting on stage is easy. The brackets are connect by Camlocs. Camloc 1/4 turn fasteners -- Safe mechanical quick release fastener systems -- Locking/unlocking by quarter turn -- Hand operated -- Service-friendly, time-saving and cost cutting -- Vibration-resistant POWER IN POWER OUT AC/DC 90 – 264 V, 50/60 Hz T max. 40° C SN Made in EU Leader Light s.r.o. Slovakia, 20__ www.leaderlight.eu 0° 18 ! DMX OUT -- Pernament use limitations for heating dissipation of LL STAGE CYC - body temperature must be less then 55°C DMX IN 04 PERNAMENT USE LIMITATIONS FOR HEATING DISSIPATION 05 MAINTENANCE AND SERVICE LL Stage CYC 6C LL Stage CYC 5C LL Stage CYC 4C LL Stage CYC 3C LL Stage CYC 2C LL Stage CYC 1C These informations are subject to change, latest data are on: www.leaderlight.eu POWER See the relevant Appendix! WARNING - Disconnect mains before remove cover! 03.5 DMX channels MADE IN SLOVAKIA www.leaderlight.eu signal. Interconnections are realized by Neutrik XLR 5pin In/Out connectors. -- Before any maintenance is necessary to carefully read all SAFETY INFORMATION 01! -- Damages caused by inadequate cleaning or maintenance are not covered by warranty. -- Requires periodic cleaning (dust, dirt ,...) Procedure for maintenance: -- Unplug mains before maintenance and at least 10 minutes cool off. -- Appliance do not illegal open or demount. -- Clean-up dust only from outer surface. Use vacuum or dumpy duster (warm water) -- Before reinstalling make sure everything is intact and dry– no wet parts! Service: AIMING POSSIBILITY The fixture could be aim to wish position with adjustable bracket. -- Customer service provided by the manufacturer. ACCESSORIES Screw the BRACKET to the surface/structure at least in 4 points ©MMXVI - LEADER LIGHT – All right reserved Edition: A - 2016 LL STAGE CYC TUBUS LL STAGE CYC POLE OPERATION BRACKET Additional information on [email protected]
advertisement
Key Features
- DMX 512 control
- AC/DC power supply
- Adjustable bracket
- High-power LED
- Surface mounting
- IP20 protection
Frequently Answers and Questions
What is the power input voltage range of the LL STAGE CYC 6C?
The LL STAGE CYC 6C accepts an AC input voltage range of 90 – 264 V.
How is the LL STAGE CYC 6C connected to the DMX control system?
The LL STAGE CYC 6C uses a standard XLR 5pin connector for DMX 512 data input and output.
What is the maximum ambient temperature that the LL STAGE CYC 6C can operate in?
The maximum ambient temperature for the LL STAGE CYC 6C is 40°C.
What type of mounting bracket does the LL STAGE CYC 6C use?
The LL STAGE CYC 6C comes with an adjustable bracket that can be mounted to a surface for secure installation.
What kind of connectors are used for power input and output on the LL STAGE CYC 6C?
The LL STAGE CYC 6C uses Neutrik PowerCon connectors for both power input and output.
Is the LL STAGE CYC 6C compatible with other DMX-controlled devices?
Yes, the LL STAGE CYC 6C is compatible with any DMX 512 control system and other DMX devices.