KOKEN LM-068 Instruction Manual

KOKEN LM-068 Instruction Manual

KOKEN LM-068 is a medical training model designed to simulate feces removal and glycerin enema procedures. It features realistic anatomy, allowing students to practice techniques with a lifelike feel. The model incorporates simulated feces, an adjustable intestine, and a drainage system for realistic practice. The model is suitable for nursing and welfare education, allowing students to learn and practice essential procedures in a safe and controlled environment.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

KOKEN LM-068 Feces Removal and Glycerin Enema Training Model Instruction Manual | Manualzz
Feces Removal and
Glycerin Enema
Training Model
LM-068
Instruction Manual
Thank you for purchasing the Feces Removal and Glycerin Enema Training Model.
Please read this instruction manual carefully to ensure correct use of the product,
and store it in a safe place for easy access.
KOKEN CO., LTD.
1-4-14 Koraku, Bunkyo-ku, Tokyo 112-0004 JAPAN
URL:http://www.kokenmpc.co.jp
E-mail:[email protected]
C-1-957-1-01-03
Handling and Safety Precautions
These precautions should be strictly observed in order to ensure safe,
long-term use of the product.
The following precautions should be observed particularly strictly:
1. This model has been manufactured to provide the same feel as a living body. Improper handling
may result in damage.
2. Do not place any items on the cover(skin). This may result in deformation.
3. For dirt on a model, wipe off with gauze moistened using a neutral detergent diluted with water
or with just water.
* Use of solvents such as thinner and benzine is prohibited.
4. When storing the product, select a place for storage where it is not exposed to direct sunlight or
ultraviolet light.
5. Use the attached enemator only for the model. Never use it for a living body.
6. Prevent the attached simulated feces from getting into the body (eyes or mouth).
1
Table of Contents
1. Outline and Features
2. Components and Configuration
3. Handling the Model
4. Maintenance
5. Specifications
2
1. Outline and Features
Outline
The techniques of feces removal and glycerin enema in the filed of nursing and welfare education
can be obtained with the same feeling as with a human body while the trainer provides precise
instructions by observing the techniques of the trainee.
Features
Feces removal
This model simulate bedridden or the aged having difficulty of self evacuation, removal of
simulated feces in the rectum can be practiced by digital insertion.
Glycerin enema
- Glycerin enema can be practiced simulating bedridden or the aged patients who are unable
to evacuate the bowels by themselves.
- Glycerin fluid can be injected. (It is let out from drainage tube at the side of abdomen.)
- By opening the abdominal cover(skin), the position of enemator’s end through transparent
intestines can be confirmed and this makes possible safe glycerin enema and its guidance.
3
2. Components and Configuration
Main body
Enemator
Intestine cap
Simulated feces(with hard feces)
Sheet
4
Drainage tube
3. Handling the Model
3-1. Glycerin Enema Model Handling Procedures
(1) Lay the sheet and set the main body as shown in the figure below.
Abdominal cover(skin)
sheet
Abdominal cover(skin)
sheet
. by connecting its pieces as shown
(2) Open the abdominal cover(skin) and set the intestine
in the figure below.
.
Connect each intestinal piece securely by hand to prevent water leakage.
5
(3) Connect a drainage tube and apply a container for drainage.
(The container is not attached.)
Connect a drainage tube by securely inserting it into a connector.
(4) Preparation of enemator.
Use this enemator only for this model.
Never use it for a living body.
Open the cap of the enemator.
(Fill water into the enemator. The maintenance after training will be easier.)
Tip nozzle cap
6
Fill water into the enemator while attaching the tip nozzle cap.
Tighten the cap.
Tighten the cap.
Fill water while attaching
Fill water while attaching
the tip nozzle cap.
the tip nozzle cap.
(5) The preparation up to the above is completed, perform training of a glycerin enema.
After removing the tip nozzle cap, use the enemator.
7
3-2 Handling procedures for Feces Removal Model
(1) Lay the sheet and set the main body as shown in the figure below.
Abdominal cover(skin)
Abdominal cover(skin)
Sheet
Sheet
(2) Disconnect the intestine.
(3) Shape simulated feces (clay for soft feces) into adequate size by hand.Tear simulated feces into pieces by hand and make them into an adequate of balls.
8
(4) Stuff simulated feces by hand into close to the anus of the anus-side intestine.
Anus-side intestine
Anus-side intestine
Anus-side intestine
Simulated feces
Simulated feces
Enlarged drawing
(5) Attach the cap for feces removal with the anus-side
intestine.
Simulated
feces
Enlarged drawing
Enlarged drawing
Tighten the cap for feces removal securely.
Tighten the cap for feces removal securely.
Tighten the cap for feces removal securely.
(6) When the preparation up to the above is completed, perform training of a feces removal.
9
4. Maintenance
4-1 After glycerin enema training
Open the abdominal cover(skin), disconnect the intestine from the connector, discharge water accumulated in the intestine canal and dry it.
4-2 After feces removal training
Insert your fingers and remove large simulated feces from the intestine. For simulated feces
adhered to the intestine, scrape them by using a ready-made toothbrush.
10
5.Specifications
Product name
Main body
Length
Approx. 33 cm
Width
Approx. 55 cm
11
Height
Approx. 35 cm
Weight
Approx. 2.8kg

advertisement

Key Features

  • Realistic anatomy
  • Simulated feces
  • Adjustable intestine
  • Drainage system
  • Enema simulation
  • Feces removal simulation
  • Safe and controlled learning environment

Frequently Answers and Questions

What is the purpose of the KOKEN LM-068 model?
The KOKEN LM-068 model is designed to simulate feces removal and glycerin enema procedures for training purposes in nursing and welfare education.
What materials are used in the model?
The model is made of materials that closely mimic the feel of a human body, allowing for realistic practice.
How do I clean the model after use?
Wipe the model with a gauze moistened with a neutral detergent diluted with water or just water. Solvents such as thinner and benzine are prohibited.

Related manuals

Download PDF

advertisement