The KELCO F40-240-HD is a heavy duty digital pump controller designed for controlling and safeguarding pumps up to 5HP. It features integrated pressure and flow sensing, automatic dry run protection, and multiple timer settings. This versatile device can be used in a variety of applications, including stock watering systems, bore water pumping, and general pressure control.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
4
INSTALLING AND USING THE KELCO F40 DIGITAL PUMP CONTROLLER WARNING OPERATING RANGE ALL MODELS Please read this installation sheet fully and carefully. The F40 Digital Pump Controller is a mains voltage device. Death or serious injury may result if this product is not correctly installed and used. Start-up Timer Adjustable from 1sec. to 3 minutes in 15 steps Run-on Timer Adjustable from 1 sec. to 5 minutes in 15 steps Restart Timer Adjustable from 1 min. to 48 hours in 15 steps INTRODUCTION Pump Start Pressure Range 0 to 5 Bars in 16 steps of 33kPa each The F40 pump controller is a microprocessor based integrated pressure and flow device. It is designed for controlling the operation of a pump and for protecting it against running dry. Maximum Starting Pressure 500kPa (72 psi) Minimum Starting Pressure 33kPa (4.7 psi) Recommended Pipe Sizes 25mm (1”) or larger. (There is no upper limit) Maximum Switched Load F40-240 250VAC 50Hz 2.4kW (Motors up to 3HP) Maximum Switched Load F40-240-HD 250VAC 50Hz 3.75kW (Motors up to 5HP) Maximum Switched Load F40240-S-4 250VAC 50Hz 2.4kW (Motors up to 3HP) Maximum Switched Load F40240-S-5 250VAC 50Hz 6Amps Non Inductive WARNING Maximum Switched Load F40-24-S-5 250VAC 50Hz 6Amps Non Inductive The F40 digital pump controller is water resistant to IP67. This rating only applies if the clear control lid is in place and its two fixing screws fully tightened. The F40 is not water resistant unless the clear lid is in place and fully secured. Always replace the clear lid and fully tighten its two screws after making changes to the settings. The F40 may present a shock hazard and death or serious injury may result if water enters the F40’s electrical housing. There are no user serviceable parts in this pump controller. Under no circumstances should the main housing be opened. Warranty on this product is automatically void if the sealed body screws are opened. Operating Pressure Range, Static or Dynamic 0 to 20 Bars (0 to 300psi) See Note Below Burst Pressure 50 Bars (750 psi) The F40 pump controller can be used in a variety of situations to control and safeguard a pump. Some models can directly control single-phase pump motors up to 5HP without the need for an interposing contactor. In addition to protecting the pump from dry run damage the F40 can be set to automatically maintain line pressure in stock watering applications or for cyclically pumping low yield stock or domestic bores. IMPORTANT This installation and usage information sheet must be read with reference to the specific model controller being installed. The power switching capacity and the pressure rating of the controllers vary from model to model and it is very important to understand the limitations of a specific controller before installing it. MODELS F40 - 240 - S - 5 SUPPLY VOLTAGE CABLE CORES 240 = 220 TO 240VAC 24 = 24V AC or DC 4 = 4 CORE 10Amp CABLE 5 = 5 CORE 6Amp CABLE CABLE NO LETTER = 10Amp PLUG & PLAY HD = HEAVY DUTY 15Amp CABLES 2 X 2M LONG S = SINGLE CABLE 2M LONG WITH 4 or 5 CORES OPERATING ENVIRONMENT ALL MODELS Supply F40-240 & F40-240-HD 220 to 250VAC 50Hz Single Phase Supply F40-24 Low Voltage AC/DC Model 12 to 28V AC or DC at 80mA Max. Ambient Temperature Range 1ºC to 50ºC Liquid Temperature Range 1ºC to 60ºC See note below Ingress Protection Rating IP67 Maximum Operating Pressure 20 Bars 300psi NOTE: The F40 pump controller must NOT be used in hot water applications (>60ºC). The F40 pump controller is rated to withstand water pressure to 20 Bars (300 psi) and must not be used in applications where the static or dynamic pressure exceeds this rating. INSTALLATION The F40 is suitable for use in all cold-water based applications such as potable water, seawater, bore water, chlorinated pool water, brackish water or filtered effluent. A suitable location should be selected for the controller in the delivery pipework of the pump. The controller should be installed in a location that is away from both vibration and heat, preferably out of direct exposure to the weather and above any flood level. A 1” BSP socket, or threaded pipe tee must be provided in the pipework to fit the controller. The controller should be located on the topside of a horizontal section of the pipe work with a minimum of 2 diameters of straight pipe either side of the controller. Under no circumstances mount the F40 under a pipe or close to valves, tees, bends or any other obstructions likely to cause major turbulence in the flow. The F40 can be mounted in vertical pipework if required, and flow can pass either in an upward or downward direction. In most installations the paddle of the F40 will need to be trimmed to suit the specific pipe tee in which it is to be installed. The paddle of the controller needs a force equivalent to 20 grams dead weight acting on it from the flow in order to operate correctly. The force is generated by water in motion pushing against the exposed area of the paddle. The more area of paddle exposed to the flow the more force available to actuate the controller. Be aware that high velocity flow can generate high forces and may damage the paddle. As a general guide the paddle of the F40 should extend to slightly past the centre line of the pipe. The paddle would not normally be left longer than this unless the expected flow rate was very low. If you know the likely flow rate and the pipe size of your pump system there is an online calculator available at www.kelco.com.au that will help you to work out an exact size to cut the paddle. Use tin snips, side cutters or a hacksaw to cut the paddle. If needed, cut away the sides of the paddle so it clears the pipe socket and pipe walls by at least 4mm at its closest point. Apply a suitable thread sealant tape or paste and screw the F40 into the socket using the spanner flats provided. When properly installed the controller should be square to the axis of the pipe, with the flow arrow on the side of the F40’s body correctly oriented and parallel to the line of flow. In addition, there should be a gap of at least 4mm between the top of the 1”BSP pipe socket and the under edge of the F40’s spanner flats. Under no circumstances should the F40 be wound into the pipe socket until its thread bottoms out in the socket as to do so places the thread in tension and may result in the controller’s housing cracking under pressure. HOW TO INSTALL AN F40 DIGITAL PUMP CONTOLLER 4mm MINIMUM GAP 1”BSP REDUCING BUSH STANDARD PIPE TEE CUT PADDLE TO CLEAR THE PIPE BY A MINIMUM OF 4mm ALL ROUND MINIMUM OF 2 DIAMETERS OF STRAIGHT PIPE EACH SIDE OF THE F40 ELECTRICAL BASIC WIRING DIAGRAMS The F40 pump controller requires a stable supply voltage in order to operate correctly. Pay particular attention to cable sizes, and ensure cables are adequate for the specific pump motor load. This is particularly important where long cable runs are to be used in the installation. If the voltage drop associated with the starting of the pump motor is excessive the F40 will automatically reset and this may cause the pump to jog. Jogging can snap the main spindle of a pump very easily, so please take all precautions to ensure the voltage supply to the F40 is stable and that the current carrying capacity of the cable is adequate for the job. Never use long or coiled extension leads (longer than 5 metres) to connect a pump to the F40. The Standard F40-240 pump controller is supplied fitted with a 10 Amp plug and socket. Pumps up to 2.4kW (P1) can be plugged directly into the socket connection to the controller. NOTE: For mains voltage applications we recommend that the supply to the F40 be isolated by a 10Amp RCD that has a maximum trip current of 30mA. WARNING NOTE GREY WIRE & BLUE WIRE ARE SUPPLIED AS VOLTAGE FREE NORMALLY OPEN CONTACTS 6Amps MAX. LOAD BLUE WIRE GREY WIRE BLACK WIRE WARNING SINGLE PHASE 220 /240VAC SUPPLY FROM CIRCUIT BREAKER Fixed Installations must only ever be carried out by a licensed electrician and must conform to local wiring rules. BROWN WIRE BLUE WIRE GREY WIRE NOTE GREY WIRE & BLUE WIRE ARE SUPPLIED AS VOLTAGE FREE NORMALLY OPEN CONTACTS 6Amps MAX. LOAD The standard F40-240 can directly control single-phase 240V~ 50Hz pump motors BLACK WIRE up to 2.4kW. When used in a fixed installation a disconnecting device such as a GREEN / YELLOW WIRE switch or a circuit breaker must isolate the F40. The disconnecting device must be easily and readily accessible after installation. Where a circuit breaker is used EARTH it must be rated at 10 Amp. Where an isolation switch is used the circuit must N INSTALLATION 5 CORE SWITCH FOR ALL LOW be protected by a 10 Amp fuse. InSINGLE thePHASE interests of USING safety a CABLE 10 Amp RCD withWATTAGE a CONTROL CIRCUIT APPLICATIONS maximum 30mA trip should also be installed in the supply. N A EARTH SINGLE PHASE INSTALLATION USING 5 CORE CABLE SWITCH FOR ALL LOW WATTAGE CONTROL CIRCUIT APPLICATIONS SUPPLY TO SWITCH 220 / 240VAC N SINGLE PHASE 220 /240VAC SUPPLY FROM CIRCUIT BREAKER 4 CORE CABLE SWITCHES ARE NOT FOR THE CONTROL CIRCUIT APPLICATION THEY ARE STRICTLY FOR THE DIRECT CONTROL OF PUMP MOTORS UP TO 2.4kW MAXIMUM TYPICAL 3 PHASE TO CONT BROWN WIRE GREEN / YELLOW WIRE SUPPLY TO SWITCH 220 / 240VAC N EARTH SINGLE PHASE PUMP MOTOR 220 / 240VAC 2.4kW MAXIMUM TYPICAL SINGLE PHASE PUMP INSTALLATION USING A 4 CORE CABLE SWITCH IMPORTANT 4 CORE CABLE SWITCHES ARE NOT SUITABLE FOR CONTROL CIRCUIT APPLICATIONS THEY ARE STRICTLY FOR THE DIRECT CONTROL OF PUMP MOTORS AS SHOWN ABOVE THEY HOUSE A POWERFUL SOLID STATE DRIVE SYSTEM THAT WILL NOT WORK IN LOW WATTAGE CONTOL CIRCUITS 5 CORE CABLE SWITCHES ARE NOT SUITABLE FOR THE DIRECT CONTROL OF PUMP MOTORS THEY ARE FOR THE CONTROL OF CONTACTORS, RELAYS, TIMERS, PLC’S, VS DRIVES AND OTHER LIGHT DUTY CONTROL CIRCUIT APPLICATIONS L3 L2 L1 UNIVERSAL LOW VOLTAGE AC 3 PHASE 415VAC SUPPLY FROM CIRCUIT BREAKER NOTE GREY WIRE & BLUE WIRE ARE SUPPLIED AS VOLTAGE FREE NORMALLY OPEN CONTACTS 6Amps MAX. LOAD CONTRAL CIRCUIT BREAKER OR FUSE CONTACTOR COIL 220 / 240V & THERMAL OVERLOAD BROWN WIRE BLUE WIRE GREY WIRE BLACK WIRE GREEN / YELLOW WIRE SUPPLY TO SWITCH 220 / 240VAC EARTH 3 PHASE PUMP MOTOR TYPICAL 3 PHASE INSTALLATION USING 5 CORE CABLE SWITCH TO CONTROL THE PUMP MOTOR CONTACTOR WARNING The F40-240-HD is supplied with heavy duty flying leads for fixed installation use only. It must be installed by a licensed electrician and isolated by a 15Amp fuse or a 15Amp circuit breaker. We recommend that the supply to the F40-240-HD be isolated by a 15Amp RCD that has a maximum trip current of 30mA. BROWN WIRE BLUE WIRE CONNECT BROWN WIRE TO LOW VOLTAGE AC OR DC SUPPLY. FOR AC CONNECT IT TO THE SUPPLY ACTIVE. FOR DC CONNECT IT TO THE SUPPLY POSITIVE. BLACK WIRE GREEN / YELLOW WIRE N NOTE GREY WIRE & BLUE WIRE ARE SUPPLIED AS VOLTAGE FREE NORMALLY OPEN CONTACTS 6Amps MAX. LOAD GREEN / YELLOW WIRE N PHASE 220 /240VAC SUPPLY FROM CIRCUIT BREAKER A SINGLE F40-240-HD MODEL ONLY SUPPLY TO SWITCH 220 / 240VAC 3 PHASE 415VAC SU BLUE WIRE FIXED INSTALLATION 4 CORE CABLE SWITCHES ARE NOT FOR THE CONTROL CIRCUIT APPLICATION THEY ARE STRICTLY FOR THE DIRECT CONTROL OF PUMP MOTORS UP TO 2.4kW MAXIMUM BROWN WIRE L3 L2 L1 BLACK WIRE When installing the F40 the socket outlet connection (GPO) for the input power must be accessible, and must be positioned in a dry and protected location out of the weather and above any flood or water level. Where the F40 is to be used to control pump motors up to 2.4kW 3HP the supply to the F40 must be protected by a 10 Amp fuse or by a 10 Amp circuit breaker. A A SINGLE PHASE 220 /240VAC SUPPLY FROM CIRCUIT BREAKER EARTH SINGLE PHASE PUMP MOTOR 220 / 240VAC 2.4kW MAXIMUM TYPICAL SINGLE PHASE PUMP INSTALLATION USING A 4 CORE CABLE SWITCH IMPORTANT BROWNOUT OR BLACKOUT 4 CORE CABLE SWITCHES ARE NOT SUITABLE FOR CONTROL CIRCUIT APPLICATIONS THEY ARE STRICTLY FOR THE DIRECT CONTROL OF PUMP MOTORS AS SHOWN ABOVE THEY HOUSE A POWERFUL SOLID STATE DRIVE SYSTEM THAT WILL NOT WORK IN LOW WATTAGE CONTOL CIRCUITS 5 CORE CABLE SWITCHES ARE NOT SUITABLE FOR THE DIRECT CONTROL OF PUMP MOTORS THEY ARE FOR THE CONTROL OF CONTACTORS, RELAYS, TIMERS, PLC’S, VS DRIVES AND OTHER LIGHT DUTY CONTROL CIRCUIT APPLICATIONS If a blackout or brownout occurs while the F40 is operating, the controller will not retain any memory of where in its run or stop cycle it may have been, it will simply shut down the pump. When power resumes, the F40 will reboot, restart the pump and run any timer settings from the beginning. A manual reboot can be done at any time by simply pressing the reset button on the top deck of the controller. ADJUSTING SETTINGS There are 4 rotary switches located under the clear cover on the top deck of the F40. These 4 dials are for adjusting the timers and pressure switch that control the F40’s actions. To access the 4 dials undo the 2 screws that hold the clear cover in place. Note that the clear cover must always be replaced and tightened after making changes to the settings. WARNING Without the cover in place the F40 is not water resistant and presents a potential shock hazard. Take great care not to splash water onto the F40 when the control cover is removed and always replace the cover immediately and fully tighten its securing screws after any changes to the settings are made. After you make any change to the settings on the 4 control dials you must always press the reset button for the changes to take effect. BROWN WIRE BLUE WIRE GREY WIRE NOTE GREY WIRE & BLUE WIRE ARE SUPPLIED AS VOLTAGE FREE NORMALLY OPEN CONTACTS, 240VAC 6Amps MAXIMUM LOAD BLACK WIRE GREEN / YELLOW WIRE CONNECT BLACK WIRE TO LOW VOLTAGE AC OR DC SUPPLY. FOR AC CONNECT IT TO THE SUPPLY NEUTRAL. FOR DC CONNECT IT TO THE SUPPLY NEGATIVE. EARTH UNIVERSAL LOW VOLTAGE AC / DC SWITCH FOR GENERAL PURPOSE CONTROL CIRCUIT APPLICATIONS No. DESCRIPTION FUNCTION 1 MASTER RESET BUTTON With power on, press this button to start the pump at any time. Always press it after making any changes to the settings on the 4 timer dials. Any changes you have made will not take effect until you press the reset button. This button can be pressed at any time even if the pump is running. All timers are reset to zero when the reset button is pressed. 2 PRESSURE SETTING This dial sets the pump’s start up pressure. The dial is adjustable from zero to 5 Bars in 16 steps of 33 kPa each. If this dial is left on zero the F40 only senses flow and not pressure. This dial is normally set to marginally higher than the system’s static pressure. When pressure falls because a tap has been turned on a point will be reached where the pressure drops to the level set on this dial. The pump then automatically starts and runs for the time set on the run-on dial (4). If there is a demand for flow the pump will run continuously and satisfy the demand. 3 START TIMER When the F40 is first turned on, or when the reset button is pressed, the start timer sets how long the pump runs for ignoring the fact that there may be no flow or pressure present at that time. The dial can be set from zero to 3 minutes in 16 steps. During this start time the pressure in the system must rise up to a level higher than the pressure set on the pressure dial (2). If the pressure fails to reach the correct level by the end of the timer’s run the pump will be automatically shut down. The F40 will then rapidly flash its red alarm light (7). Pressing the reset button (1) re-runs the start timer and adds pressure to the system until the pressure rises above the pressure that is set on the pressure dial (2). 4 RUN-ON TIMER If the flow is interrupted for any reason while the pump is running this timer sets how long the loss of flow is ignored before the pump automatically shuts down. It can be set from zero to 5 minutes in 16 steps. The run-on timer also determines how long the pump runs for if it is triggered by a pressure drop that reaches the pressure set on the pressure dial (2). Is should be set to long enough for the pressure to rise up above the pressure dial (2) set pressure. 5 STOP TIMER If the F40 goes into alarm mode due to being run dr, this dial sets how long the pump will remain off before the F40 attempts to restart it. This dial is adjustable from zero to 48 hours in 16 steps. If the stop timer is set to zero the pump will not try to restart automatically but if run dry will simply remain in alarm mode, rapidly flashing its red warning light till attended to. 6 START TIMER LED This light shows steady blue whenever the start-up timer is running. It means the pump is running under the control of the start up timer and the light is letting you know that when the start timer times out the pump will either continue to run, if there is a demand for flow, or automatically shut down and wait for a pressure drop or flow demand to re-trigger it. 7 FLOW STATUS & ALARM LED This light will show a steady green whenever the paddle of the F40 is held on by flow. It will be on at all times there is a modest flow through the system. This light also pulses slowly red whenever the F40 is powered up and in standby mode. It indicates that everything is OK and the F40 is simply waiting for a flow demand or a pressure drop to re-start the pump. This light also flashes rapidly red in alarm mode if the F40 senses that the pump has run dry. If the stop timer is running this light turns steady red indicating the pump has stopped but will re-start after whatever delay is set on the stop timer dial (5). 8 RUN-ON TIMER LED This light shows steady red whenever the run-on timer is running. If you have set the run-on timer to say 5 seconds to ignore air bubbles in the pipework then the pump will keep running and this light will come on steady red for 5 seconds every time air passes through the system. This light also shows steady red whenever the system starts up on pressure drop. On a pressure start it must be set to remain on long enough for the pressure to rise above the pressure that is set on the pressure setting dial (2). 9 FLOW SENSITIVITY ADJUSTMENT Under this dust cap is a screw that sets the sensitivity of the F40 to flow. As supplied, this screw is wound fully in which is its least sensitive position. By winding this screw anti-clockwise (out) the F40 can be set to detect progressively lower flows. In other words become more sensitive and responsive to low flows. The screw should not be wound out beyond where the dust cap can be refitted. The F40 will not operate if this screw is fully removed. Use a wide bladed screwdriver to adjust this screw. 10 PADDLE The paddle (a replaceable item) must be trimmed to suit the intended application. Normally the paddle is cut so when installed it intrudes to a little past the centre line of the pipe. The more area of paddle exposed to the flow the more responsive the F40 will be. The paddle is normally trimmed with a pair of tin snips or a hacksaw. It can be narrowed down and its end rounded to suit the specific pipe in which it is to be installed. The paddle should always be trimmed so there is a minimum of 4mm clearance to the closest adjacent pipe walls. If you know the likely flow rate and the pipe size of your pump system there is an online calculator available at www.kelco. com.au that will help you to work out an exact size to cut the paddle. TYPICAL LARGE PUMP SYSTEM CONTROLLED BY AN F40 PUMP RUN-ON TIMER AIR CELL F40 DIGITAL PUMP CONTROLLER BLEED VALVE ISOLATION VALVE ISOLATION VALVE SUCTION PIPE The run-on timer can be set to suit the specific application, for example, it can be set to several minutes to pressurise long pipes or a large air cell. It will keep your pump running for up to 5 minutes after the flow has reduced to a point below where the paddle of the F40 can detect. Alternatively, it could also be set to only a few seconds to simply allow the pump to ignore minor fluctuations in flow. The run-on timer only starts when pressure has dropped to whatever pressure you have set on the pressure dial, or the flow has essentially stopped. For example, air passing through the flow switch would normally stop the pump due to the paddle detecting the momentary loss of flow. The run-on timer will keep the pump running seamlessly and ignore this loss of flow for whatever time period it is set to. SERVICE CHECK VALVE BASIC OPERATION - NO TIMERS USED With the three timer dials set to zero the F40 pump controller only responds to flow in a basic way. It will behave like a basic on/off flow switch, it will simply turn on and off in direct response to paddle movement. Any pump connected to it will also start and stop in direct response to the actual flow past the paddle of the switch. Power can be switched on to such a system and the pump will not automatically start unless there is initially enough flow past the paddle of the F40 to actually turn it on. This inability to automatically start is the very reason why a timer is normally required to override the off state and start the pump. The only condition under which such a system would automatically start would be if there was flow from some external source, such as from an air cell or a gravity feed from an elevated water source. START TIMER Setting the start timer (3) will override the off state of the F40 so that when power is applied, your pump will start and will run for whatever time you have set on the start timer dial. The blue light (6) will be on while the timer is running, and if correctly set, and if there is a flow demand, flow will push the paddle (10) to its on position before the start timer times out. Flow is indicated by the flow status light (7) turning steady green in response to the flow. When correctly set the start timer should run for slightly longer than the time it takes for the water flow to actuate the paddle of the F40 and for the flow status light (7) to come on steady green. The start timer and the run-on timer function independently of each other and are totally flexible. For example you can set the start timer to 3 seconds, to get a pump started, and the run-on timer to 5 minutes to run a pump on and pressurise a pipe system or an air cell. Alternately, you could set the start timer to 3 minutes to allow a bore pump with a self-draining riser time to fill its pipework, and you could also set the run-on timer to 3 seconds to ignore bubbles of entrained gas in the pipe system. Note that the run on period will only commence when the flow has reduced to a lower rate than the F40 is able to detect. STOP TIMER The stop timer sets how long the pump remains off once it has been run dry. It can be set on zero or from 1 minute to 48 hours in 15 steps. The stop timer can be set for sufficient time for the standing water level in a bore to recover. At the end of the stop time the pump will automatically restart under the control of the F40. By using the loss of pressure as detected by the F40 when a pump is run dry, a bore pump can be cycled and a low yield bore pumped to its maximum yield. The alarm (7) will turn a steady red whenever the stop timer is running. This is to indicate to you that while the pump is off it will restart automatically at the end of whatever time is set on the stop time dial. MAINTAINING PRESSURE IN PIPE SYSTEMS It is often highly desirable to maintain pressure in pipe systems, for example in a stock watering system where long runs of pipe are involved and draw off at the stock troughs is highly variable. Controlling a pressure pump in such systems can be very difficult. A pump under the control of an F40 can be set to start on pressure drop when a remote float valve opens and run while ever there is a flow demand and then automatically stop when the flow demand ceases. The F40 will then monitor the pressure and restart the system whenever the pressure drops again. In such a system air cell pressure or simply line pressure is lost as stock drink. Often this slight drop in pressure is too low to be detected by a normal pressure switch. An F40 can automatically start the pump and run it for however long it takes for the line to pressurise and for the flow to stop. This may take hours or minutes and may vary considerably from time to time. If for any reason flow is lost while the pump is running this will be detected by the F40 and the pump will be shut down. The pump will then attempt to restart and repeat the whole process after waiting for whatever time the stop timer has been set to. A PUMP SYSTEM WITH NO AIR CELL CONTROLLED BY AN F40 F40 INSTALLED BEFORE THE AIR CELL (SEE TEXT) DISCHARGE PRESSURE SYSTEMS The F40 pump controller can be used to protect a conventional pressure start pressure stop pump from running dry if flow is lost. In a conventional pressure system a pressure switch turns the pump on when the pressure drops and switches it off when the pressure rises. All such systems have one basic flaw, if they run out of water for any reason the lack of pressure will hold the pressure switch on and keep the pump running. The result is usually severe damage to the pump. The F40 is an ideal alternative because it monitors flow as well as pressure and will stop the pump from running dry by detecting the loss of flow. The pump will switch on on a falling pressure and switch off when flow ceases. AIR CELL AND PUMP STARTS AIR CELL F40 PUMP CONTROLLER PUMP SUCTION F40 INSTALLED AFTER THE AIR CELL (SEE TEXT) AIR CELL An air cell is not essential in a pump system controlled by an F40. An air cell can be used in a pump system to store pressure energy and provide the motive power to trigger the system and restart the pump. The F40 relies on either pressure drop or flow to start a pump. If an F40 is installed in a pump system before the air cell, any demand at the tap will be met by the draw off from the air cell until the pressure falls to the level set on the F40’s pressure dial. The pump will then start and if there is an on going demand continue to pump. In such a system the draw off capacity of the air cell and the flow demand will determine how frequently the pump starts. A large capacity air cell will reduce the frequency of starting and thus the cycling of the pump. A small draw off air cell will give a more constant pressure but at the expense of more frequent starting. If the F40 is installed after the air cell, any more than a slight flow from the air cell will start the pump on flow. If the flow demand is extremely low, eventually the pump will simply start on pressure drop once the pressure reaches the pressure dials set point. Where a system is required to supply a constant pressure the F40 should be mounted after the air cell. When pump cycling is to be kept to a minimum, the F40 should be mounted before the air cell and a large draw off capacity air cell should be used in the system. F40 PUMP CONTROLLER PUMP DISCHARGE SUCTION SUBMERSIBLE BORE PUMP CONTROLLED BY AN F40 F40 DIGITAL PUMP CONTROLLER DISCHARGE PUMP SENSITIVITY ADJUSTMENT A sensitivity adjusting screw (9) is provided for fine-tuning the F40. Under the end of the switch housing is a hex-headed plug that covers the adjusting screw. Remove the plug and using a broad-bladed screwdriver wind the adjusting screw anticlockwise to increase the sensitivity (reduce the flow rate needed to actuate the paddle.) As supplied, the screw is wound fully in and the F40 is set to its least sensitive. The maximum sensitivity is reached with the screw wound out to a point where the hex dust cover can still be refitted. Normally the sensitivity screw should be left fully in. If the paddle has been trimmed too short the resultant loss of sensitivity can be offset by winding the sensitivity screw out a few turns. LIMITATIONS The mains voltage F40 pump controller requires a stable 220 to 240 V AC 50Hz supply in order to operate properly. Where large pumps are connected to an F40 care should be taken to ensure cable sizes are adequate. Never use the F40 with long or coiled extension leads or on generator sets. The electronics built into the F40 are protected against surges and brownout and these protection systems can be triggered by voltage drop, severe voltage spikes, or by an erratic electrical supply. The F40 should only be used in ambient temperature water applications. It is neither designed for, nor is it intended to be used with liquids other than water. The F40 pump controller must never be used in hot water applications (greater that 60ºC) and must also be protected from freezing. The standard F40-10 is designed to withstand water pressures up to 20 Bars, (300 psi) and must not be used in applications where either the static or dynamic pressure exceeds this rating. WARNING If the F40 Pump Controller is used in a manner not specified by the manufacturer the protection provided by the device may be impaired or negated. In addition all warranties stated or implied will be rendered invalid. MADE IN AUSTRALIA BY KELCO Engineering Pty Ltd ABN 20 002 834 844 Head Office and Factory: 9/9 Powells Road BROOKVALE 2100 AUSTRALIA Postal Address: PO Box 496 BROOKVALE NSW 2100 Phone: +61 2 99056425 Fax: +61 2 99056420 Email: [email protected] Web: www.kelco.com.au PLEASE NOTE: The Kelco F40 Digital Pump Controller is the subject of Australian and international patent and trademark applications. Kelco Engineering Pty Ltd reserves the right to change the specification of this product without notice. Kelco Engineering Pty Ltd accepts no liability for personal injury or economic loss as a consequence of the use of this product. All rights reserved copyright Kelco Engineering Pty Ltd © 2010
advertisement
Key Features
- 5HP motor control
- Integrated pressure & flow sensing
- Dry run protection
- Multiple timer settings
- IP67 water resistance
- Heavy Duty flying leads
- 15A fuse/circuit breaker required
Frequently Answers and Questions
What is the maximum starting pressure for the F40-240-HD?
The maximum starting pressure is 500kPa (72 psi).
What is the maximum operating pressure for the F40-240-HD?
The maximum operating pressure is 20 Bars (300 psi).
Is the F40-240-HD compatible with hot water applications?
No, the F40-240-HD must not be used in hot water applications (greater than 60ºC).