Omron K6EL, K6EL-500 Manual
Omron K6EL-500 is a high-speed, compact ground fault relay designed for use in low-voltage circuits. It features a selectable operating time of less than 0.1 seconds and is engineered for high reliability, even when working with inverter loads. The K6EL-500 offers flexibility with its switchable sensed current, allowing you to adjust sensitivity based on your specific application requirements. For remote monitoring, the automatic-reset models provide continuous fault detection and alert you to potential issues. The K6EL-500 is compatible with a range of through-type ZCTs (Zero-phase Current Transformers), simplifying installation and ensuring seamless integration into your electrical system.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Ground Fault Relay K6EL Economical, Compact, High-performance, DIN 48 u 48-mm Ground Fault Relay for Low Voltages • Performs continuous monitoring and detection of ground faults in low-voltage circuits due to the deterioration of insulation in electrical devices. • Higher reliability ensured with improved resistance to high-frequency noise when used for inverter loads. • Remote monitoring of cubicles is possible with automatic-reset models. • Ground Fault Relays and through-type ZCTs (zero-phase current transformers) are mutually compatible. • The through-type ZCTs are equipped with test terminals, allowing operation tests for Ground Fault Relays to be performed with ease. • Series now includes K6EL-R50, which operates at 50 mA r10%. Model Number Structure ■ Model Number Legend K6EL-@@ 1 2 3 1. Ground Fault Relay 2. Operating Time and Reset Method None: 0.1 s manual reset A: 0.3/0.8 s (switchable) manual reset R: 0.5 s automatic reset 3. Sensed Current 30: 30 mA (fixed) 50: 50 mA/150 mA (switchable) 100: 100 mA/200 mA (switchable) 200: 200 mA/500 mA (switchable) 500: 500 mA/1,000 mA (switchable) Ordering Information ■ List of Models Manual-reset Ground Fault Relays Type Type High-sensitivity models Sensed current 30 mA (fixed) Operating time Medium-sensitivity models 100 mA/200 mA (switchable) 200 mA/500 mA (switchable) 500 mA/1,000 mA (switchable) High-speed models Less than 0.1 s K6EL-30 K6EL-100 K6EL-200 K6EL-500 Delayed models 0.3/0.8 s (switchable) --- K6EL-A100 K6EL-A200 K6EL-A500 Automatic-reset Ground Fault Relays Type Type Operating time Delayed models Less than 0.5 s Sensed current High-sensitivity models Medium-sensitivity models 50 mA/150 mA (switchable) 500 mA/1,000 mA (switchable) --- K6EL-R500 K6EL-R50 (See note.) --- Note: Operating Error 50-mA tap: r10% 150-mA tap: r20% http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 1 K6EL ZCTs (Zero-phase Current Transformers) Type Rated current Indoor through-type models Sensed current Model Indoor separate-type models Diameter of through-hole Model Diameter of through-hole 50 A OTG-L21 21 mm --- --- 100 A OTG-L30 30 mm --- 22 mm 200 A OTG-L42 42 mm OTG-CN52 52 mm 400 A OTG-L68 68 mm OTG-CN77 77 mm 600 A OTG-L82 82 mm OTG-CN112 112 mm 1,000 A OTG-L156 156 mm --- --- ■ Ground Fault Relay and ZCT Combinations (OK: Compatible) Ground Fault Relay K6EL-30 K6EL-R50 ZCT K6EL-100, -200, -500, -R500 K6EL-A100, -A200, -A500 OTG-L21 (50 A) OK OK OTG-L30 (100 A) OK OK OTG-L42 (200 A) OK OK OTG-L68 (400 A) --- OK OTG-L82 (600 A) --- OK OTG-L156 (1,000 A) --- OK OTG-CN52 (200 A) --- OK OTG-CN77 (400 A) --- OK OTG-CN112 (600 A) --- OK Note: 1. “OK” indicates groupings that can be combined freely. 2. Combinations with the OTG-LA@@ are also possible. ■ Options Flush Mounting Adapters Front Cover Model Model Y92F-30 Y92A-48B (Hard Cover) Y92F-71 Y92A-48D(Soft Cover) Specifications ■ Ground Fault Relay Ratings Type High-speed models Delayed models Item Control power supply 100/110 VAC or 200/220 VAC, 50/60 Hz (same for all) (See note 1.) Rated current Depends on the ZCT Sensed current 50% to 100% of the rated sensed current (50 mAr10%, 150 mA r20%) (See note 2.) Non-operating current 0% to 50% of the rated sensed current Rated short-time current 2,500 A Ground fault indication method LED (red) Test method Relay operation confirmed using a test button. (Independent of ZCT connection.) Reset method Built-in contacts Manual Either press the reset button or turn the control power supply OFF and ON again. Automatic Automatically resets when the ground fault is cleared. Delayed high-sensitivity models 100 VAC Contact form SPDT+SPST-NO SPDT Carrying current 5A 3A Rated load 240 VAC cosI = 1 cosI = 0.4 (L/R = 7 ms) cosI = 1 5A 2A 220 VAC, 3 A 110 VDC 0.3 A 0.2 A 30 VDC 5A 3A Power (VA) consumption 3 VA max. Weight Approx. 110 g Note: 1. The K6EL-R50 requires a 100-VAC control power supply. 2. Only the K6EL-R50 can be switched between 50 mA r10% and 150 mA r20%. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 2 K6EL ■ Ground Fault Relay Characteristics Item Type High-speed models Delayed models Operating time Less than 0.1 s 0.3 s/0.8 s (switchable) Inertial non-operating time --- 0.1 s when set to 0.3 s 0.5 s when set to 0.8 s Control power supply range 80% to 110% of the control power supply voltage Delayed high-sensitivity models Less than 0.5 s Operating temperature 10 to 55 qC (with no icing) range Operating humidity range 45% to 85% (with no condensation) Insulation resistance 5 M: min. at 500 VDC (between charged parts and the mounting panel) Dielectric strength 1,500 VAC, 50/60 Hz for 1 min (between charged parts and the mounting panel) Lightning impulse dielectric strength 1.2/50 Ps, 7,000 V (between control power supply terminals) Lightning impulse operation failure 1.2/50 Ps, 7,000 V (primary side of ZCT) Vibration resistance Destruction: 16.7 Hz, 4-mm double amplitude for 1 min Shock resistance 98 m/s2 Note: The range for an operating time of 0.3 s is 0.15 to 0.45 s and the range for an operating time of 0.8 s is 0.6 to 1.2 s. ■ ZCT (Zero-phase Current Transformer) Item Structure Model Indoor through-type models OTG-L21 Indoor separate-type models OTG-L30 OTG-L42 OTG-L68 OTG-L82 OTG-L156 OTG-CN52 OTG-CN77 OTGCN112 Rated current 50 A 100 A 200 A 400 A 600 A 1,000 A 200 A 400 A 600 A Diameter of through-hole 21 mm 30 mm 42 mm 68 mm 82 mm 156 mm 52 mm 77 mm 112 mm Rated voltage 600 VAC max., 50/60 Hz, single-phase/three-phase Output terminal polarity None (The ZCT’s output terminals k and l can be connected to either input terminals 3 or 4 of the Relay.) (See note.) Insulation resistance 100 M: min. (between charged metal parts and ground) Dielectric strength 2,200 VAC, 50/60 Hz for 1 min (between charged metal parts and ground) Ambient operating temperature 10 to 60 qC (with no icing) Weight Approx. 90 g Approx. 130 g Approx. 230 g Approx. 480 g Approx. 700 g Approx. 6.6 kg Approx. 1.3 kg Approx. 2.5 kg Approx. 3.5 kg Note: Do not connect ZCT output terminals k and l to ground. Doing so may result in damage to the Relay. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 3 K6EL Internal Block Diagram X/c 9 Note: 1. The K6EL-R50 does not have terminals 6 and 7. 2. The K6EL-R500 and K6ELR50 do not have terminal 2. (They cannot be used at 200/ 220 V.) Delayed models only 8 Operating time selection switch 11 X/a Operating time setting circuit 6 (See note 1.) Reset button 3 Input protection circuit From OTG ZCT 4 Operating value setting circuit Sensitivity selection switch (not provided on the K6EL-30) Amplifier circuit 7 Switching circuit X Ground fault indicator (red) Test button Power supply circuit Shock-wave absorption circuit 2 1 Operation at 200/220 V (See note 2.) Operation at 100/110 V 10 Power supply indicator (green) Nomenclature POWER LEAKED K6EL-A100 Power supply indicator (green) Ground fault indicator (red) EARTH LEAKAGE RELAY TEST RESET Reset button (black) (not provided on automatic-reset models) Test button (red) SENSITIVITY Sensitivity selection switch (not provided on the K6EL-30) 100 mA 200 mA Operating time selection switch (delayed models only) 0.3S 0.8S OPERATING TIME Connections Ground Fault Relay (from Pin Side) Ground Fault Relay with P3GA-11 (from Terminal Side) Ground Fault Relay with P2CF-11 (from Terminal Side) (See note 1.) From ZCT 5 5 6 7 4 8 9 3 2 10 1 11 From ZCT 4 From ZCT 3 2 6 7 8 8 9 1 Control power supply 10 11 1 5 4 From ZCT 3 From ZCT 2 100 VAC 100 VAC 200 VAC 200 VAC (See note 2.) 6 9 11 10 100 VAC 200 VAC 7 Control power supply Note: 1. The K6EL-R50 does not have terminals 6 and 7. 2. The K6EL-R500 and K6EL-R50 do not have terminal 2. (They cannot be used at 200/220 V.) http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 4 K6EL Connection Examples Installation on the Electrical Path Molded case circuit-breaker Installation on a Ground Bus Bar Molded case circuit-breaker ZCT Transformer Load Load Transformer kt OTG ZCT Y/b lt k Y/b OTG ZCT Auxiliary relay kt l Y k l Auxiliary relay lt Y ZCT 5 6 7 4 8 3 9 2 10 1 11 Alarm buzzer BZ Alarm buzzer BZ 100/110 VAC K6EL Ground Fault Relay Ground bus bar K6EL Ground Fault Relay 5 6 7 4 8 3 9 2 10 1 11 200/220 VAC Do not, under any circumstances, connect the k and l lines to ground. Note: When not using the kt and lt terminals (test terminals), leave them unconnected. The Relay may not be able to attain its performance characteristics if used with the kt and lt terminals connected. 100/110 VAC 200/220 VAC Dimensions Note: All units are in millimeters unless otherwise indicated. Ground Fault Relay 1 78 6 63.7 0.7 13.6 44.8 × 44.8 48 Applicable Connecting Sockets P2CF-11 Front Connecting Socket P3GA-11 Back Connecting Socket PL11 Back Connecting Socket 48 http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 5 K6EL Dimensions with Adapter Mounted Y92F-30 Flush Mounting Adapter (Sold Separately) Panel 15 Mounting Hole Cutout Dimensions P3GA-11 Back Connecting Socket R0.5 max. 58 45 +0.5 0 45 +0.5 0 Note: Recommended panel thickness: 1 to 3.2 mm. 48 7 91.4 Panel Y92F-71 Flush Mounting Adapter (Sold Separately) 56 Mounting Hole Cutout Dimensions P3GA-11 Back Connecting Socket R0.5 max. 45±0.2 58 68 45 +0.5 0 55 +0.5 0 91.4 45±0.2 Note: Recommended panel thickness: 1 to 3.2 mm. 50±0.2 Dimensions for Socket Mounting Y92F-30 P3GA-11 K6EL + Adapter K6EL 103 77 Y92H-1 Hook K6EL 91.4 7 P2CF-11 (sold separately) 16 PL11 (sold separately) (sold separately) Note: The same dimensions apply when using the Y92F-71 Adapter. Connecting Sockets P2CF-11 Front Connecting Socket 3 Eleven, M3.5×7.5 sems screws 4.5 7.8 Terminal Arrangement (Top View) Mounting Holes Two, 4.5-dia. holes 8 7 6 5 4 70 max. 40±0.2 35.4 Two, 4.5-dia. holes 9 3 10 11 1 2 4 50 max. 31.2 max. P3GA-11 Back Connecting Socket 27 dia. Terminal Arrangement (Top View) 45 25.6 5 6 7 8 4 3 9 2 1 11 10 45 http://www.ia.omron.com/ 4.5 16.3 6.2 (c)Copyright OMRON Corporation 2007 All Rights Reserved. 6 K6EL PL11 Back Connecting Socket 4 3.5 1 Terminal Arrangement (Bottom View) Two, 3.5-dia. holes or two, M3 socket mounting holes 5 6 7 30 dia. 51 max. 40 4 3 2 3.9 1 11 Two, 2-dia. holes 35 max. Mounting Holes 8 9 10 31 dia. holes 40±0.3 Approx. 20.5 Front Cover Model Y92A-48B (Hard Cover) Y92A-48D (Soft Cover) ZCT 9.3 Indoor Through-type Models OTG-L21 (50 A) 11 50 20 13 6 Mounting Hole Cutout Dimensions Terminal symbols (protrude 0.3 mm) Nameplate kt k l lt Label and caution 66 21 dia. 6 Two, 5.5-dia. holes or two, M5 screw holes 64 74 5.2 20 64 OTG-L30 (100 A) 9.3 11 20 13 63 Mounting Hole Cutout Dimensions Terminal symbols (protrude 0.3 mm) 6 kt k l lt Nameplate Two, 5.5-dia. holes or two, M5 screw holes 79 30 dia. 76 6 86 5.2 20 76 OTG-L42 (200 A) 11 9.3 5.2 Mounting Hole Cutout Dimensions 17 88 42 dia. Two, 5-dia. holes or two, M4 screw holes 109 97 97 (mounting pitch) 107 OTG-L68 (400 A) 25 11 9.3 6.1 17 118 Mounting Hole Cutout Dimensions 68 dia. Two, 5-dia. holes or two, M4 screw holes 136 131 13 (mounting pitch) 143 http://www.ia.omron.com/ 31 (c)Copyright OMRON Corporation 2007 All Rights Reserved. 7 K6EL 11 OTG-L82 (600 A) 9.3 6.2 138 17 Mounting Hole Cutout Dimensions 82 dia. Two, 5-dia. holes or two, M4 screw holes 158 160 28 160 (mounting pitch) 172 OTG-L156 (1,000 A) 33 156 dia. L M5 terminal screws Mounting Hole Cutout Dimensions 263 Four, 8.5-dia. holes or four, M8 screw holes 138 90 230 270 3.2 60 230 9 90 130 20 40 Indoor Separate-type Models OTG-CN52 (200 A) 52 dia. K M4 terminal screws Mounting Hole Cutout Dimensions Two, 6.5-dia. holes or two, M6 screw holes 141 K 79 170 170 30 7 http://www.ia.omron.com/ 200 (c)Copyright OMRON Corporation 2007 All Rights Reserved. 8 K6EL OTG-CN77 (400 A) 77 dia. M4 terminal screws K Mounting Hole Cutout Dimensions 157 Four, 6.5-dia. holes or four, M6 screw holes 84 K 53 195 195 70 53 7 230 112 dia. OTG-CN112 (600 A) K M4 terminal screws Mounting Hole Cutout Dimensions Four, 6.5-dia. holes or four, M6 screw holes 200 107 K 53 225 225 70 53 7 260 ■ Maximum Wire Sizes for ZCTs Wire/cable Model Rated current 600-V vinyl-insulated wire (IV) Through-hole diameter 2-wire OTG-L21 50 A 21 dia. 22 mm2 14 mm2 OTG-L30 100 A 30 dia. 2 2 OTG-L42 200 A OTG-L68 OTG-L82 60 mm Cable (VVR) 3-wire 38 mm 2-wire 8 mm2 38 mm 5.5 mm2 2 38 mm2 42 dia. 100 mm 2 100 mm 2 100 mm 400 A 68 dia. 400 mm2 325 mm2 325 mm2 600 A 82 dia. 500 mm2 500 mm2 400 mm2 OTG-L156 1,000 A 156 dia. 500 mm 2 500 mm 2 OTG-CN52 200 A 52 dia. 200 mm 2 200 mm 2 OTG-CN77 400 A 77 dia. 500 mm 2 400 mm 2 OTG-CN112 600 A 112 dia. 500 mm2 500 mm2 http://www.ia.omron.com/ 3-wire 2 1,000 mm 60 mm2 250 mm2 400 mm2 2 1,000 mm2 150 mm 2 100 mm2 400 mm 2 325 mm2 1,000 mm2 1,000 mm2 (c)Copyright OMRON Corporation 2007 All Rights Reserved. 9 K6EL Test Circuit Switch 200 mA: 500 :, 50 W 500 mA: 200 :, 100 W 1,000 mA: 100 :, 200 W 100 VAC Slidac mA Ammeter K6EL kt k l lt OTC R Select the resistance R shown in the test circuit diagram according to the K6EL’s rated sensed current. Change the current using the slidac and ascertain the K6EL’s operating value each time by reading the ammeter. For example, R could take the values shown below: 30 mA: 3.3 k:, 6 W 100 mA: 1 k:, 20 W Safety Precautions ■ Correct Use Switching the Operating Time Installation and Wiring • Do not, under any circumstances, connect the ZCT’s output terminals k and l to ground. Doing so may result in damage to the Relay’s internal circuits. • Pass the primary conductor through the ZCT once. • The Relay detects ground faults in internal wiring of devices due to insulation deterioration and so install the ZCT as close to the power supply side as possible. 1. With the K6EL-A100, A200, and A500, the operating time can be switched using a flat-bladed screwdriver. 2. The operating time for the K6EL-30, 100, 200, 500, R50, and R500 is fixed and hence cannot be switched. ZCT Installation • Install the ZCT at an outdoor cable inlet or on a ground bus bar at a location allowing easy inspection. • When installing on the electrical path, use a ZCT with a value greater than the electrical path’s rated current. • If the secondary lines run in parallel to a circuit carrying a large current, either separate the lines as far as possible or use a shield line. Run the secondary lines close to each other. Sensed current selection switch Operating time selection switch Testing ZCT K6EL Primary conductor Separate by 20 cm min. Circuit carrying large current • When installing a separate-type ZCT with current flowing along the primary conductors, short the secondary terminals using clips or some other method. Switching the Sensed Current • If the ground fault indicator (red) lights when the Relay’s test button is pressed, it means that the internal circuits are operating normally. • To make an overall test, run a simulated ground fault current. Resetting • Once manual-reset models operate, they continue to operate until they are reset. Reset them either by pressing the reset button (black) or by turning the control power supply OFF and ON again. • Automatic-reset models reset automatically when the ground fault is cleared (i.e., the current drops below the sensed current). 1. With the K6EL-@100, 200, 500, R50, and R500, the sensed current can be switched using a flat-bladed screwdriver. 2. The sensed current for the K6EL-30 is fixed and hence cannot be switched. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 10 K6EL Q&A Q: How does the K6EL operate when used for inverter loads (e.g., inverter motors and inverter air conditioners)? A: The influence of high-frequency noise generated by the inverter has been reduced by combining a special ground fault relay IC and a capacitor for cutting out high-frequencies. The possibility of malfunctions due to the influence of the inverter is much less than with the existing ESA Ground Fault Relay. R S M Inverter T Rg K6EL Q: What connection method should be used for ungrounded electrical paths? A: With ungrounded electrical paths, connect the capacitor or resistor for detection in the way shown in the diagram. The table shows the formulas for calculating the resistance or capacitance as well as the formulas for calculating ground currents for complete ground faults. (Depending on the location, the allowable ground fault current may be restricted. In this case, use values of R and C that do not exceed the restrictions.) Connection method OTG ZCT Y/b kt Resistor (R) or capacitor (C) l k lt Rg K6EL Y Ig It: Ground Fault Relay’s set value V: Line voltage 2 f: Frequency P= 5V (W) R P: Allowable power for the resistor used Capacitor: (A tolerance is C= 2It (F) included in the 2πfV formulas on the Dielectric strength left.) > 2 V (V) Formula for ground current Formula for safety ground fault Resistor: Isolating transformer Load Singlephase electrical path Formula for resistor or capacitor R= V (Ω) 2It Ig= Ig= V (A) 2Rg + R V 1 (2Rg) + ( 2πfC )2 Ig= V (A) R (A) Ig = 2πfCV (A) 2 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 11 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. COPYRIGHT AND COPY PERMISSION This catalog shall not be copied for sales or promotions without permission. This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety. 2007. 3 OMRON Corporation In the interest of product improvement, specifications are subject to change without notice. Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.
advertisement
Key Features
- High-speed operation
- Compact design
- Inverter compatibility
- Switchable sensed current
- Automatic reset