Bromic Heating BH0110002-1 Installation, Instruction And Service Manual

Bromic Heating BH0110002-1 Installation, Instruction And  Service Manual

Bromic Heating BH0110002-1 is a Platinum Smart-Heat Gas Radiant Heater designed for outdoor spaces. It features electronic controls, allowing remote operation from a switch. The heater is built to withstand outdoor conditions and is suitable for both commercial and residential premises. It can be mounted on a wall or ceiling pole, and offers a range of safety features. Consult the manual for installation, operation, and maintenance instructions to ensure proper use and longevity.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Bromic Heating BH0110002-1 Installation Manual | Manualzz
Platinum Smart-heat™
Gas heater
BY BROMIC
Installation, instruction and
service manual
SUITABLE FOR GAS RADIANT HEATER MODELS:
Platinum 300 - burner AND Platinum 500 - burner
!
DANGER
If you smell gas:
1.
Shut off gas to the appliance
2.
Extinguish any open flame
3.
If odor continues, keep away from the
appliance and immediately call your gas
supplier or fire department.
!
WARNING: For Outdoors Use Only.
English version from pages 1 - 27
Version 2.1 USA - CANADIAN
!
WARNING
Do not store or use gasoline or other flamable
vapor and liquids in the vicinity of this or any
other appliance.
An LP-cylinder not connected for use shall not be
stored in the vicinity of this or any other appliance.
!
WARNING: Improper installation,
adjustment, alteration, service or maintenance
can cause property damage, injury or death.
Read the installation, operating and
maintenance instructions thoroughly before
installing or servicing this equipment.
! IMPORTANT
This manual contains important information about the assembly, operation, and maintenance of
Platinum Smart-Heat Series Heaters. Please pay close attention to the important safety information
shown throughout this instruction manual. Any safety information will be accompanied by the
following safety alert symbols:
! DANGER,
! WARNING,
! IMPORTANT
• READ THIS MANUAL CAREFULLY before installing or
servicing this product.
•
Improper installation, operation, or maintenance can result in
death, severe injury, or property damage.
•
Installation must be carried out by Authorized person/s in
accordance with local codes, or in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.1/NFPA 54,
Natural Gas and Propane Installation Code, CSA B149.1, or
Propane Storage and Handling Code, B149.2.
• The heater, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the National Electrical code, ANSI/NFPA 70 or the
Canadian Electrical Code, CSA C22.1.
•
This appliance is to be used ONLY for outdoor use
•
When installed outdoors this appliance MUST be protected
from rain.
Head Office: 1 Suttor Street, Silverwater, Sydney, NSW 2128 Australia
Telephone: 1300 276 642 (within Australia) or +61 2 9748 3900 (from overseas) Fax: +61 2 9748 4289
Email: [email protected] Web: www.bromicheating.com
Note: Bromic Heating Pty Ltd reserves the right to make changes to specifications, parts, components and equipment without prior notification.
This Installation, operation and service manual may not be reproduced in any form without prior written consent from Bromic Heating Pty Ltd.
2
www.bromicheating.com
CONTENTS
IMPORTANT NOTES & WARNINGS
4
PRODUCT OVERVIEW
5
PRODUCT DESCRIPTION
5
SPECIFICATIONS
5
GENERAL INFORMATION
6
PRODUCT FEATURES
6
INSTALLATION REQUIREMENTS
6
GAS REQUIREMENTS
6
INSTALLATION CLEARANCES
7
INSTALLATION INSTRUCTIONS
8
HEATER INSTALLATION INSTRUCTIONS
8
GAS SUPPLY INSTALLATION
12
POWER SUPPLY INSTALLATION
12
LEAKAGE TEST
12
HEAT DEFLECTOR INSTALLATION INSTRUCTIONS
13
CEILING MOUNT POLE INSTALLATION INSTRUCTIONS
13
OPERATING INSTRUCTIONS
14
TURNING THE APPLIANCE ON
14
TURNING THE APPLIANCE OFF
14
MAINTENANCE AND SERVICING
14
REGULAR SERVICE REQUIREMENTS
14
EXTERIOR SERVICING
14
OPTIMUM MOUNTING DISTANCE
15
HONEYWELL CONTROL
15
HONEYWELL VALVE
16
OPERATION DATA - FENWAL CONTROL BOX
17
DUNGS GAS VALVE
18
WHITE RODGERS GAS VALVE
18
WIRING DIAGRAM
19
REPLACEMENT PARTS
22
POST-INSTALLATION REPORT
24
TROUBLE SHOOTING
25
APPENDIX A
26
www.bromicheating.com
3
IMPORTANT NOTES AND WARNINGS
•
! WARNING
•
•
•
•
•
•
•
•
THIS APPLIANCE SHALL NOT BE INSTALLED OR USED
IN RESIDENTIAL DOMESTIC INDOOR AREAS
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE
HAZARDS OF HIGH SURFACE TEMPERATURES AND
SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING
IGNITION
YOUNG
CHILDREN
SHOULD
BE
CAREFULLY
SUPERVISED WHEN THEY ARE IN THE AREA OF THE
HEATER
DO NOT USE OR STORE FLAMMABLE MATERIALS
NEAR THIS APPLIANCE
CLOTHING OR FLAMMABLE MATERIALS SHOULD NOT
BE HUNG FROM THE HEATER OR PLACED ON OR
NEAR THE HEATER
DO NOT SPRAY AEROSOLS OR FLAMMABLE MATERIALS
IN THE VACINITY OF THIS APPLIANCE WHILE IT IS IN
OPERATION
ANY GUARD OR OTHER PROTECTIVE DEVICE
REMOVED FOR SERVICING THE HEATER (conducted by
an authorized person) MUST BE REPLACED PRIOR TO
OPERATING THE HEATER
INSTALLATION AND REPAIR SHOULD BE DONE BY A
QUALIFIED SERVICE PERSON. THE HEATER SHOULD
BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY
BY A QUALIFIED SERVICE PERSON
Failure to follow the warnings and instructions in this manual
could result in severe personal injury, death or property
damage.
•
•
•
•
•
•
•
•
•
•
4
This Installation, Operation and Maintenance manual
should not be removed from the site of installation.
Installer should leave manual with the customer for future
reference.
This Appliance is for outdoor areas only. (see attached
diagrammatical representations of outdoor areas
“Appendix A”).
Do not perform maintenance until heater has been
turned off, power disconnected, and heater temperature
has cooled to room temperature.
Do not expose the burner to water or moisture. The
appliance is to be protected from rain.
Do not use the heater if any of these parts are exposed
to water until the appliance is inspected or repaired by
an authorized service person.
The installer is to ensure that the requirements of the local
authority, local gas fitting regulations, municipal building
codes, and any other relevant statutory regulations are
carried out.
Certain materials or items, when stored under or near the
appliance, will be subjected to radiant heat and could
be seriously damaged. Ensure combustible materials eg.
overhead structures, walls, floors, furniture, fixtures and
plants are kept at least 3ft from the top and side.
The whole gas system, hose assembly, regulator, pipes,
and burner should be inspected for damage and leaks
before use and at least annually by an authorized person
for the life of the heater.
All leak tests should be done with a soap solution. Never
use an open flame to check for leaks.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Do not use the heater until all connections have been
leak tested by an authorized person.
Inspect the hose assembly before each use of the
appliance.
The hose assembly must be replaced prior to the
appliance being put into operation if there is evidence of
excessive abrasion or wear, or if the hose is damaged.
The replacement hose assembly must be CSA
approved.
The hose assembly is not to be located in areas where
the hose may be subject to accidental damage
This radiant heater is NOT intended to be installed on
recreational vehicles and/or boats.
Repair to be carried out ONLY by an authorized person.
Improper installation, adjustment, or alteration can cause
personal injury, property damage, or even death.
Do not attempt to alter the unit in any manner.
Remove transit protection before use.
Never operate the heater in an explosive environment
such as areas where gasorline or other flammable liquids
or vapours are stored.
Turn off the gas supply immediately if smell of gas is
detected.
Do not paint any surface of the heater.
Do not throw objects at the heater.
The fascia breaks, discontinue use, disconnect power
and gas and isolate area affected by breakage.
Control compartment, burner and circulation air
passageways of the heater must be kept clean. Frequent
cleaning may be required as necessary.
Turn Gas Supply off when not in use.
Check the heater immediately if any of the following
occurs:
»» The heater does not reach temperature.
»» The burner makes popping noise during use (a
slight noise is normal when the burner is ignited or
extinguished).
Young children should be supervised to ensure that they
don’t play with the appliance.
This appliance is not intended for use by young or infirm
persons unless they have been adequately supervised
by a responsible person to ensure that they can use the
appliance safely.
Check for damage to the appliance regularly. If damage
to the cord, plug or appliance is suspected, discontinue
use immediately and contact the supplier or qualified
person for repair.
If the cord, plug or appliance is damaged, unplug from
the outlet, discontinue use immediately, and only an
authorized person or similar may repair the unit.
Avoid inhaling fumes emitted from the heater’s first
use. Smoke and odour from the burning of oils used in
manufacturing will appear. Both the smoke and odour
will dissipate after approximately 30 minutes.
Ensure that a watertight seal is maintained on the
electrical control box at all times
Regularly check for damage to the rubber seals. If
damage to the rubber seals is suspected, discontinue
use immediately, switch off power and contact the place
of purchase or authorized service technician for repair.
www.bromicheating.com
PRODUCT OVERVIEW
PRODUCT DESCRIPTION
The Platinum Smart-Heat Gas Radiant Heaters are designed to provide effective outdoor heating to both commercial and
residential premises whilst offering an appealing design.
The heaters incorporate full function electronic controls, allowing them to be operated remotely from a conveniently located
switch. The heaters have been designed to withstand the rigors of the outdoors.
SPECIFICATIONS
Platinum 300 burner
Platinum 500 burner
Gas type
Propane (LPG)
NATURAL GAS
Manufactured by
bromic Heating Pty Ltd - 1 Suttor St Silverwater, NSW, 2128, Sydney Australia.
Approval No.
Propane (LPG)
NATURAL GAS
ETL & cETL Listing 4009079
Gas Consumption
23,600 BTU
23,600 BTU
39,800 BTU
39,800 BTU
Propane Gas (LPG) Only
Natural Gas
Propane Gas (LPG) Only
Natural Gas
Max. Line Pressure
14” W.C.
14” W.C.
14” W.C.
14” W.C.
Min. Line Pressure
11” W.C.
6” W.C.
11” W.C.
6” W.C.
Manifold Pressure
At Valve Test Point
10” W.C.
5” W.C.
10” W.C.
5” W.C.
Orifice Size
0.85mm
1.3mm
0.85mm
1.3mm
Weight
33lb
33lb
44lb
44lb
Voltage
110 Volt
110 Volt
110 Volt
110 Volt
Current
< 2 Amp
< 2 Amp
< 2 Amp
< 2 Amp
Gas Type
Platinum Smart-Heat Heater Dimensional Details
12.0"
10.4"
5.9"
8.7"
Platinum 300 = 22.1"
Platinum 500 = 29.8"
4.6"
5.3"
1.1"
.7"
13
11.7"
Without Heater
Deflector
16.6"
15.9"
Wall Bracket / Control Housing
Mounting Hole Positions
19.6"
11.9"
With Heater
Deflector
13.9"
10.1"
10.9"
! IMPORTANT
This appliance is NOT approved for indoor use and must be installed by authorized persons only in accordance with
local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Natural Gas and
Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2.
This appliance is to be protected from rain. Install under a protective cover.
www.bromicheating.com
5
PRODUCT OVERVIEW CONTINUED...
GENERAL INFORMATION
The Platinum Series Gas radiant heaters are suitable for outdoor spaces. In addition to the installation instructions provided,
authorized installers must abide by local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code,
B149.2. Please note that these standards are subject to change.
The heater is designed to function in winds up to 10mph. The heater is subject to reduced performance or failure in adverse
weather conditions such as high wind or extreme saturation.
PRODUCT FEATURES
Platinum Smart-Heat gas radiant heaters are revolutionizing the outdoor heating industry by introducing groundbreaking
benefits never seen before in traditional gas or electric heaters. Platinum Smart-Heat heaters have set the industry benchmark
with stylish good looks and world-first innovation.
Platinum Smart-Heat heaters excel in the areas of:
•
•
•
•
•
Aesthetic appeal
Innovation
Performance
Flexibility
Cost effectiveness
For more detailed product information, visit www.bromicheating.com
INSTALLATION REQUIREMENTS
! IMPORTANT
GAS REQUIREMENTS
This appliance shall only be used in above ground open-air
situations with:
• natural ventilation
• without stagnant areas
• where gas leakage and products of combustion are
rapidly dispersed by wind and natural convection
Any enclosure in which the appliance is used shall comply
with one of the following:
1. An enclosure with walls on all sides, but at least one
permanent opening at ground level (ref. Appendix A,
Example 1)
2. Within a partial enclosure that includes an overhead
cover and no more than two walls (ref. Appendix A,
Example 2)
3. Within a partial enclosure that includes an overhead
cover and more than two walls, the following shall apply:
• At least 25% of the total wall area is completely open
(ref. Appendix A, Example 4), and
• At least 30% of the remaining wall area is open and
unrestricted (ref. Appendix A, Example 4)
Platinum LPG Models:
• Use Propane (LPG) gas only
• The approved manifold pressure to the appliance is
10”W.C.
• The MIN inlet pressure to the appliance is 11” W.C
• The MAX inlet pressure to the appliance is 14” W.C
Platinum Natural Gas Models:
• Use Natural Gas Only
• Always use Natural Gas Regulator (supplied internal to
the gas valve)
• Ensure that Inlet pressure to the regulator does not
exceed 14” W.C.
• The MIN inlet pressure to the appliance is 6” W.C
• The approved manifold pressure to the appliance is
5”W.C.
Note: The definition of outdoors is an above ground openair situation with natural ventilation, without stagnant areas,
where gas leakage and products of combustion are rapidly
dispersed by wind and natural convection.
6
www.bromicheating.com
INSTALLATION REQUIREMENTS CONTINUED...
INSTALLATION CLEARANCES
When selecting the installation location for the Platinum
Series Heaters, the following mounting clearances should be
followed.
Care should be taken to ensure that the heater is not installed:
• Where heat/ignition can cause damage to gas cylinders/
lines
• Near other combustible materials
• In open locations subject to rain
• In indoor residential locations
• In areas without sufficient clearances (refer below)
Note: When Installing with No protective cover, the following
installation clearances shall apply:
Note: When installing with the Platinum Smart-Heat
Heat Shield (Part No. 2620165 or 2620166) the following
installation clearances Shall Apply:
A
A
B
Minimum Mounting Height to Ground
Minimum Mounting Height to Ground
B
C
Minimum height to combustible materials
C
Minimum height to combustible materials
Model
A
B
C
Model
A
B
C
300 Series
3ft
3ft
8ft
300 Series
14”
3ft
8ft
500 Series
3ft
3ft
8ft
500 Series
14”
3ft
8ft
Note: Heater should be installed in such a way so as to allow
adequate;
Clearance around air openings to combustion chamber
Clearance from combustible material
Provisions for accessibility and clearance for combustion and
ventilating air supply.
www.bromicheating.com
7
INSTALLATION INSTRUCTIONS
HEATER INSTALLATION INSTRUCTIONS
! WARNING
This appliance must be installed and used in accordance
with local codes, or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, Natural Gas
and Propane Installation Code, CSA B149.1, or Propane
Storage and Handling Code, B149.2 and must meet all the
requirements stipulated in the “Installation Requirements”
section of this manual.
!
Step 2. Connect CSA approved Flexible Gas Connector
(as supplied) to the inlet fitting on the heater
using 2 wrenches to tighten. Leak Test by applying
compressed air (1/2” PSI) to open end of flexible
hose. Spray gas fittings with a soapy water solution
and Check for leaks. Alternatively, leak check can be
done after assembly using inspection hole on bracket
arm. (see. leakage test section of this manual).
WARNING:
Installation should be done by a qualified service person.
! CAUTION
Please see specifications for the weight of the Heater. The
installer of the Platinum Smart-Heat Radiant Heaters must
comply with all relevant State Occupational Health & Safety
Regulations.
Step 1. Mount Wall Bracket/Control Housing To Wall:
•
•
•
Remove Wall Bracket/Control Housing From
Packaging
Place the mounting bracket in position and mark
the fixing hole location on the wall. Drill holes using
appropriate drill size and type.
Attach the bracket to the wall using appropriate
fixtures
Step 3. Fix Mounting Arm to the back of the heater –
•
Slide Gas Connector and Wiring Harness inside the
centre of the arm and have them exit through the
shaped cut-out on top surface of the arm
•
Ensure that the arm faces downwards at a 55º angle
•
Position the 4 mounting holes on the arms plate
over the corresponding fixtures on the heater Manipulate the gas hose as necessary to allow for
correct alignment
•
Insert and tighten 4 M6 bolts as provided to fit
mounting arm to heater.
! IMPORTANT
The Heater shall be firmly and securely attached to the wall.
For Brick and masonry, use M8 “Flush Head” “Dynabolts”
(or equivalent). For Wood / Timber fixtures, use suitable
screw fixings no less than 60mm in length.
! WARNING
When mounting wall bracket/ control housing, ensure the
anchoring to the structure is of sufficient strength, quality
and workmanship to support the weight of the heater and
any other load that could be applied to the fixture.
8
www.bromicheating.com
INSTALLATION INSTRUCTIONS CONTINUED...
Step 4. Attach Heater to Wall Bracket/Control Housing
•
Remove Front Cover from Control Housing
•
Attach Heater to Wall Bracket/Control Housing
by inserting Mounting Arm into lower channel of
Wall Bracket. Ensure that the Gas Hose and Wiring
Harness slide through the groove on top side of
the control Housings lower channel and remain
undamaged by the metals edges during assembly.
•
It may be necessary to manipulate the gas Hose so
that the arm can slide into place.
TIP: Do not install the mounting pin at this point.
Step 5. Connect the CSA approved flexible connector to
the Gas Valve Outlet Fitting
•
Position heater and hose so that the gas hose and
fitting are in alignment
•
NOTE: ensure that the hose nut and valve fitting are
parallel to one another and threads are engaged
correctly before tightening! Incorrect installation can
cause gas leaks and damage components.
TIP: Sliding the mounting arm inside the control
housing’s channel can help accurately Position the Gas
hose in place under the gas valve’s fitting.
•
Spanner Tighten using 2 wrenches, and leak test
using soapy water (see section “leakage test”)
www.bromicheating.com
9
INSTALLATION INSTRUCTIONS CONTINUED...
For Honeywell Control
6. Insert Pivot Bolt
•
Position Arm so that the rear hole’s on the mounting
arm and Control Housing are in alignment
•
Insert Bolt and washer (as supplied) through Control
Housing and Mount Arm, using the hole located on
the bottom surface of the Control Housing, towards
the rear. Spanner tighten in place
•
•
Using a pair of needle nose pliers, grip the white
ionisation terminal as shown, being mindful of the
terminal pins of the control module.
Ignition (smaller terminal)
Ionisation
(larger terminal)
Select desired heater angle and insert the M6 Bolt
and washer (as supplied) through the bottom surface
of Control Housing into the mounting arm, using the
corresponding hole. (Heaters angle will be 0º, 10º or
20º). Spanner tighten in place
! IMPORTANT
Electrical connections must be completed by trained and
authorized electrical technicians only!
•
Insert the ionisation terminal into the terminal pin
furthest away.
•
Ensure that the terminal firmly clicks into place.
•
Insert Repeat the process with the black ignition
cable inserting the terminal into the closer, smaller
terminal pin.
•
Insert Plug the green earth terminal into one of the
available spade terminals attached to the top of the
wall bracket.
7. Connect the 3 wires from the heater by carefully following
the instructions below (Wiring harness)
PLEASE NOTE: THERE IS NO NEED TO
REMOVE OR UNPLUG THE CONTROL
MODULE FROM THE GAS VALVE OR
WALL BRACKET ASSEMBLY
10
www.bromicheating.com
INSTALLATION INSTRUCTIONS CONTINUED...
For Fenwal Control
• Feed wiring harness (3 wires) through opening
under Fenwal controller so that wires are positioned
to the left of the controller.
8. Connect gas inlet fitting to mains gas supply in
accordance with local gas installation code and
gas supply installation section of manual. Leak test
with soapy water.
9. Fix Front cover to control housing using the 4xM4
screws provided.
•
Connect black ignition cable directly to control
box at terminal marked:
•
Connect white ionisation cable directly to control
box at terminal marked: S1
•
Connect ground terminal over ground tab,
attached to body of control housing and marked
with the symbol:
10. Main Power supply connection is to completed in line
with instructions in the “Power supply installation”
section of this manual.
! IMPORTANT
Ensure that a water tight seal is maintained.
! IMPORTANT
After gas installation and electrical installation is complete,
all gas lines should be tested for leaks using a soapy water
solution. See Section titled “Leakage Test” for further
information. Ensure gas pressure meets the requirements
outlined in Gas Supply Installation above.
www.bromicheating.com
11
INSTALLATION INSTRUCTIONS CONTINUED...
GAS SUPPLY INSTALLATION
POWER SUPPLY INSTALLATION
! WARNING
! IMPORTANT
•
All gas supply installation work must be performed by
trained and authorized person(s) and comply with the
requirements of local Gas Installation Codes.
•
All Piping Joints should be tested for leaks with a
soapy water solution before use.
•
Gas hose must be located out of pathway where
people may trip over it, or in areas where the hose
may be subject to accidental damage.
Verify the type of gas supply complies with the appliance
rating plate, located at the back of the heater.
The inlet connection to the heater control box is a 1/2” NPT
Female.
The Control box has been fitted at the factory with an
approved manual isolating valve in accordance with local
Gas Installation Codes.
This heater is equipped with a three-prong (grounding)
plug for your protection against shock hazard and should
be plugged directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong from
this plug.
The Platinum Smart-Heat Heater comes standard with 36” of
power cord in addition to the Approved 3 pin power plug.
If an appropriate power socket is available, the heater can be
plugged into this power socket and operated using the on/
off switch supplied on the power socket. Alternatively, the
power installation can be tailored to suit the site requirements
by an Authorized Electrician.
Keep electrical supply cord away from any heated surface
and flue gasses.
Please Note:
Platinum Smart-Heat Heaters do not have their own on/off
switch. Operation should be controlled via the main power
! WARNING
Ensure that power socket is switched off before plugging
in power cord.
supply.
LEAKAGE TEST
Tighten all the connections and then turn on the gas supply.
Check for gas leakage with a soapy water solution. (See
section titled “Leakage Test”).
Gas connections on the heater are leak tested at the factory
prior to shipment. A complete gas tightness check must be
performed at the installation site due to possible mishandling
in shipment or excessive pressure being applied to the
heater. Check ALL connections.
•
The heater must be checked with the gas supply turned
on.
Make sure the safety control valve is in the OFF position.
Make a soap solution of one part liquid detergent and
one part water. The soap solution can be applied with a
spray bottle, brush or rag. Soap bubbles will appear in
case of a leak.
Turn the gas supply ON.
In case of a leak, turn off the gas supply. Tighten any
leaking fittings, then turn the gas supply on and recheck.
Never leak test while smoking.
The following points MUST be leak checked before
operation.
Do not use an open flame to check for leaks.
When the heater is operating, check gas pressure at the test
point and ensure the manifold pressure to the heater is:
NG:
5” W.C.
LPG: 10” W.C
Gas supply pressure must be limited to 14” W.C. If gas line
pressure exceeds this level, a separate pressure reducing
regulator must be installed.
The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2 psi.
•
•
•
•
•
•
1
The appliance must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig.
12
www.bromicheating.com
2
INSTALLATION INSTRUCTIONS CONTINUED...
4. Fix Heater to Lower paddles using suitable fixtures.
3
NOTE: Platinum Heating recommends running power and
gas lines, to the heater, inside the pole to reduce visibility
and likelihood of damage.
HEAT-DEFLECTOR INSTALLATION
1
2
3
CEILING POLE INSTALLATION
! WARNING
When mounting ceiling pole, ensure the anchoring to the
structure is of sufficient strength, quality and workmanship
to support the weight of the heater and any other load that
could be applied to the fixture. Note: Ceiling pole must be
perpendicular (90deg) to the ground when mounted
(irrespective of pitched or flat ceiling).
1. Mount Top Bracket to ceiling or support beam using
suitable fixings no less than 60mm length.
2. Assemble pole to the mounting bracket using the
M8x100mm and M19x100mm bolts, and fix using nuts
and washers (as supplied).
4
3. Assemble both lower paddles to the pole (back to back)
and insert 3 M10x100mm bolts and fix using nuts and
washers (as supplied).
www.bromicheating.com
13
OPERATING INSTRUCTIONS
TURNING THE APPLIANCE ON
1. Ensure that gas installation and power installation has
been carried out in accordance with the manufacturers
instructions outlined in this document.
2. Turn on gas supply.
NOTE: The appliance must be completly shutoff for a period
of 5 minutes before being relighted.
! IMPORTANT
Check the heater immediately if any of the following occurs:
3. Ensure correct gas supply pressures are set.
•
The heater does not reach temperature.
4. Switch on power to heater.
•
5. If Gas heater does not light, turn power off.
6. Wait 5 seconds before turning power back on. If
heater does not ignite after 5 attempts, consult the
troubleshooting section of this manual, or contact Bromic
Heating Pty. Ltd for service information.
The burner makes popping noise during use (a slight noise
is normal when the burner is ignited or extinguished).
Note: Avoid inhaling fumes emitted from the heater’s first
use. Smoke and odour from the burning of oils used in
manufacturing will appear. Both the smoke and odour will
dissipate after approximately 30 minutes.
TURNING THE APPLIANCE OFF
1. For temporary shutdown, turn off power.
2.
For permanent shutdown, turn off power and shut off gas supply.
Installers please Note:
When the installation and testing is completed, make sure
that the customer knows how to operate the heater. Leave
the operating instructions with the customer.
MAINTENANCE AND SERVICING
It is important that regular maintenance is carried out on the
heater to maintain efficient operation. All maintenance should
be carried out ONLY by authorized service personnel.
3. Clean burners: Burners can be cleaned by directing
compressed air (max20PSI) at outlet ports. Avoid directing
air at gasket material between ceramic tile and burner cup.
Control compartment, burner and circulation air passageways
of the heater must be kept clean. Inspect and clean at least
every six months or more frequently in adverse conditions.
4. Clean manifold and injectors: Undo gas hose from gas
valve outlet (heater should be switched off) and inject
compressed air (max20PSI) down the inlet fittings.
Never obstruct the flow of combustion and ventilation
air. Always keep the appliance area clear and free from
combustible materials, gasoline and other flamable vapors
and liquids.
5. Clean dust and foreign matter from inside of heater
housing: Open up rear housing and clear dust using
compressed air (max20PSI) and a damp cloth.
Do not clean heater with cleaners that are combustible or
corrosive.
REGULAR SERVICE REQUIREMENTS
1. CSA approved Gas Hose, located within the mounting
arm, must be checked at least once annually. The hose
must be replaced if there is any evidence of excessive
wear, or if the hose is damaged. The replacement hose
assembly must be CSA approved with 3/8”SAE flared
ends. To Check the Gas Hose, remove control housing
cover by removing 8 screws and slide cover outwards.
Alternatively, disassemble heater by reversing the
installation instructions as outlined in Installation section
of this handbook.
2. VISUALLY CHECK BURNER FLAMES. During heaters
function visually check that all burners are alight and
glowing hot. This can be done by observing the red
glow through the face, or by peering down the product
combustion passageway. Note: A slight variation in colour
is to be expected.
6. Remove debris, spider and insect nests from, control
compartment, burner and circulation air passageways of
the heater with heavy-duty pipe cleaner or compressed
air to keep appliance clean and safe for use. Never clear
ports or other openings with toothpicks or other articles
that will break and block the ports.
7. In a salt-air environment, such as near an ocean, corrosion
occurs more quickly than normal. Check frequently for
corroded areas and repair them promptly.
! IMPORTANT
More frequent cleaning may be required as necessary. It is
imperative that control compartment, burners and circulating
air passageways of the heater be kept clean.
EXTERIOR SERVICING
The exterior Platinum Smart-Heat Heater components are
constructed from stainless steel, and high temperature coated
black paint. For all exterior black parts (excluding fascia trims),
a brushed finish has been used. This is not a coating and under
prolonged use, may slightly discolour from high temperatures
emitted by the heater. This is a normal occurrence and does
not affect the operation of the appliance.
Replacement parts can be purchased to restore the heater to
1
14
2
3
4
5
www.bromicheating.com
its original appearance from Bromic Heating Pty Ltd. (Refer to
parts list in manual).
! IMPORTANT
Do not apply any additional surface coating to the heater under any
circumstances. Use of additional coating other than those applied
during manufacture could result in hazardous reactions such as
toxic fumes or fires. Additional coatings will void the warranty.
OPTIMUM MOUNTING DISTANCE
A
B
B
A
Model
A
B
Model
A
300 Series
3ft
8 - 10ft
300 Series
19 - 23ft
500 Series
3ft
8 - 10ft
500 Series
26 - 29ft
OPERATION DATA - HONEYWELL CONTROL BOX
The following operation sequence is valid only where the
components are installed according to the manufactures
assembly and installation instructions. Please do not modify
the wiring configuration, gas train or any other part of the
heater assembly.
TECHNICAL DATA
Application
The Honeywell electronic gas burner control system is suitable
for atmospheric gas burners for non-permanent operation.
Although the Honeywell unit is available non volatile lockout,
its configuration in the Platinum Smart-Heat series heaters
limits it to volatile lockout, i.e. the restart from this condition
is possible by the interruption and subsequent restoration of
the mains power supply.
Timings:
Features:
•
Compliance with CSA standard for automatic gas burner
flame monitoring and control systems
•
Compliance with EN 298 (European standard for
automatic gas burner flame monitoring and control
systems)
•
Compliance with AGA (Australian standard for automatic
gas burner flame monitoring and control systems)
•
Flame monitoring based on rectification property of the
flame (ionisation)
Supply voltage
110V-50/60Hz
Operating temperature
-20°C
Ambient humidity
90%max at 40°C
Protection degree
IPX4
Self Check time
1.5 s
Safety time (TS)
25 s
Drop out time on running flame failure
1s
Power consumption, at start up
10VA
Power Consumption, Running
4VA
+60°C
Ignition
Ignition Voltage
15kV with 40pF load
Spark repetition rate
33 Hz
Max. Cable length
1M
Recommended spark gap
0.14”
Consumption
2,5 VA
Spark energy
3 uAs
www.bromicheating.com
15
OPERATION DATA - HONEYWELL CONTROL BOX CONTINUED...
Directions for use
Operation
•
Automatic controls are safety devices and shall not be
opened. The manufacturer’s responsibility and guarantee
are invalid if the control is unduly opened.
•
A regulation shutdown must occur every 24hours to
enable the unit to check its own efficiency (systems for
non permanent operation)
At every start, the control unit proceeds to a self-checking
of its own components. During the pre-purge or waiting
time (TW) the internal circuit makes a test of the flame signal
amplifier. Extraneous light or fault in the amplifier will result
in the simulation of a flame which will prevent the control
from starting.
•
Connect and disconnect the unit only after switching off
the power supply
•
Avoid exposing the unit to dripping water
•
Ventilation and the lowest temperature ensures the
longest life of the control
Electrical Installation
•
Live and Neutral should be connected correctly; a mistake
could cause a dangerous situation.
•
Before starting the system check cables carefully for
incorrect installation
•
The earth terminal of the control, the metal frame of the
burner and the earth on the mains supply must be well
connected
At the end of the waiting or pre-purge time, the gas valve is
energised and the ignition device is operated. In this way, the
safety time (TS) begins.
If a flame is detected during the safety time, the ignition
device is inhibited and the gas valve remains energised.
If the control does not detect any flame signal during the
safety time, at the end of safety time (TS), the unit proceeds
to lockout and the gas valve and ignition device are switched
off.
If the established flame signal is lost, (during the safety time
or during operation thereafter) this will cause the ignition
device to be reactivated within 1 second.
If the burner does not light within 25 seconds of ignition
reactivation, the heater will enter failure lockout mode and
must be reset.
OPERATION DATA honeywell valve:
The VK series gas control have been specially developed for
application in domestic appliances. The Honeywell Gas Valve
is a multi-functional control which incorporates an adjustable
direct acting pressure regulator. It is designed for operation
on 220/240V.
Adjust Regulator Pressure
Standard Specifications
•
1/2” G Female Pipe Thread connection
•
Ambient Temperature Range of 0°C to 60°C
•
Compact Size: 86.5mm x 63.5mm x 65.9mm
•
50mb Pressure Rating
•
1/2” x 1/2” (BSP- G) Inlet and Outlet
•
Earthing terminal – 6mm spade tab
•
Tamper resistant screws
•
Top mounted coils that can be field replaced
•
Unscrew the regulator cover.
•
Unscrew the outlet plug to measure the outlet regulator
pressure by using manometer.
•
Adjust the pressure by turning the regulator screw
clockwise or anti wise.
•
Adjust the pressure according to appliance specification.
! IMPORTANT
Remember to place the regulator cover, outlet and inlet back
on.
Inlet Pressure
TECHNICAL DATA
Max inlet working pressure
50 mbar
Installation group
Group 2
Operating Temperature
0°C to 60°C
Voltage Ratings
220/240VAC
50/60Hz .52A
16
www.bromicheating.com
Outlet Pressure
Regulator
OPERATION DATA - FENWAL CONTROL BOX
The Series 35-60 is 24 VAC Microprocessor Based Direct
Spark Ignition Controls designed for use in all types of
heating applications. The control utilizes a microprocessor
to continually and safely monitor, analyze and control the
proper operation of the gas burner. The following operation
sequence is valid only where the components are installed
according to the manufacturers assembly and installation
instructions. Please do not modify the wiring configuration,
gas train or any other part of the heater assembly.
Application
The Fenwal electronic gas burner control system is suitable
for atmospheric gas burners for non-permanent operation.
The Fenwals configuration in the Platinum Smart-Heat series
heaters limits it to volatile lockout, i.e. the restart from this
condition is possible by the interruption (for 5 seconds) and
subsequent restoration of the mains power supply.
Features:
•
24 VAC microprocessor based DSI control
•
Pressure switch monitoring
•
System diagnostic LED
•
Alarm output (normally closed contact)
•
Automatic reset 1 hour after lockout*
•
Custom prepurge and interpurge timings**
•
Multiple tries for ignition
•
Remote or local flame sensing
•
Flame sense test pins
Operation
When a call for heat is received from the thermostat
supplying 24 volts to TH/W, the control will reset, perform a
self check routine, flash the diagnostic LED, and a pre-purge
delay begins. Following the pre-purge period the gas valve
is energized and sparks commence for the trial for ignition
period.
When flame is detected during the trial for ignition, sparks are
shutoff immediately and the gas valve remains energized. The
thermostat and main burner flame are constantly monitored
to assure the system continues to operate properly. When
the thermostat is satisfied and the demand for heat ends, the
main valve is de-energized immediately.
Should the main burner fail to light, or flame is not detected
during the trial for ignition period, the control will go into
lockout. The valve will be turned off immediately. Multi-try
Models will attempt two additional ignition trials before
going into lockout. The valve relay will be de-energized
immediately.
Recovery from lockout requires a manual reset by removing
24 volts from 24 VAC(R) for a period of 5 seconds. If there is
still a call for heat after one hour the control will automatically
reset and attempt to ignite the burner again.
Directions for use
If the established flame signal is lost the control will respond
within 0.8 seconds. The HV spark will be energized for a
trial ignition period in an attempt to relight the burner. If
the burner does not light the control will de-energize the
gas valve. Multi-try models will make two more attempts to
relight the burner. If the burner does not relight the control
will go into lock out as noted above. If flame is re-established,
normal operation resumes.
TECHNICAL DATA
Automatic controls are safety devices and shall not be
opened. The manufacturer’s responsibility and guarantee are
invalid if the control is unduly opened.
Supply voltage
18 to 30 VAC 5060Hz
Operating temperature
-40°F
A regulation shutdown must occur every 24hours to
enable the unit to check its own efficiency (systems for non
permanent operation)
Ambient humidity
95%max at 104°F
Protection degree
IP00
Connect and disconnect the unit only after switching off the
power supply
Self Check time
1.5 s
Avoid exposing the unit to dripping water
Safety time (TS)
10 s
Drop out time on running flame failure
0.8 s
+176°F
Timings:
Ventilation and the lowest temperature ensures the longest
life of the control
Power consumption, at start up
300mA Max.
Power Consumption, Running
300mA Max.
Electrical Installation
Ignition
•
•
The applicable state and local standards regarding
electrical safety must be respected.
Ignition Voltage
15kV with 40pF load
Spark repetition rate
50/60 sparks/ sec.
Live and Neutral should be connected correctly; a
mistake could cause a dangerous situation.
Max. Cable length
1M
Recommended spark gap
3.5mm
•
Before starting the system check cables carefully for
incorrect installation
•
The ground terminal of the control, the metal frame of
the burner and the ground on the mains supply must be
well connected
www.bromicheating.com
17
OPERATION DATA - DUNGS GAS VALVE
The Dungs GB Valve is a multifunctional Gas Control with
combined regulator and safety shutoff valves.
The pressure regulator includes a servo regulator to regulate
pressure fluctuations in the mains supply. This ensures a
precise volume flow and constant injector pressure.
To shut down the pressure regulator turn the setting device
25 times clockwise until a soft click can be heard.
TECHNICAL DATA
Opening Time
Fast Opening <1sec
Slow Opening <10 sec
Closing Time
<1 sec
Voltage Frequency
~(AC) 50 - 60 Hz 24 V +10
% – 15 %
Load of coil (24 V, 230 V)
2 x 5,5 VA
Electrical connection
Molex System connection
coil or Option: Connection
box with integrated cable
Installation position
Solenoid at any position
between vertical and horizontal axis.
Standard Specifications
TECHNICAL DATA
Gas Connection
1/2” RP
Max Inlet Pressure
65 mbar
Pressure Range
2.5mbar to 38mbar
Nominal Flow
3,3 m3/h (Air)
Ambient temperature
5 °F to -158 °F
32 °F to -158 °F at LPG
Automatic shut-off valves
Class B as per EN 126
Group
2
Pressure Regulator
Class C
Degree of protection
IP40
OPERATION DATA - WHITE RODGERS VALVE
The White Rodgers Gas Valve is a compact multi-functional
control which incorporates an adjustable direct acting
pressure regulator. It operates on 24V.
Standard Specifications
•
Inlet Screen – will filter to 180 microns
•
Ambient Temperature Range of 32°F to -140°F
•
Compact Size: 86.5mm x 63.5mm x 65.9mm
•
50mb Pressure Rating
•
Class ‘B’ Group 2 Direct Acting Solenoid Valves with
high sealing force
•
3/8” x 3/8” (BSP PI.) Inlet and Outlet
•
Opening time < 0.25 seconds
•
Closing time < 0.25 seconds
•
Earthing terminal – 6mm spade tab
•
Tamper resistant screws
•
Top mounted coils and electronics that can be field
replaced without entering the gas stream.
18
TECHNICAL DATA
Max Working pressure
50 mbar
Installation group
Group 2
Operating Temperature
32°F to -140°F
Regulator adjustment range
9.2 to 13.7 mbar
Voltage Ratings
24VAC
50/60Hz
www.bromicheating.com
WIRING DIAGRAM - HONEYWELL CONTROL, HONEYWELL GAS VALVE
ELECTRICAL DIAGRAM
SEE INSTRUCTION MANUAL FOR DETAILS ON HOW
TO CONNECT THE ELECTRICAL COMPONENTS.
L
Black 110 V
N White
Red 230 V
Blue
Yellow/Green
12
11
10
9
Purple
Purple
Green
E
TRANSFORMER
Ionisation
Ignition +
8
N/A
7
6
5
4
3
2
1
Yellow/Green
HONEYWELL
White
Black
Yellow/Green
Note:
If any of the original wire as supplied with the heater must be replaced, it must be replaced with 18AWG, 90ºC type UL
approved wire or its equivalent. If Transformer must be replaced, a UL approved model of similar type must be used.
www.bromicheating.com
19
WIRING DIAGRAM - FENWAL CONTROL, WHITE RODGERS GAS VALVE
ELECTRICAL DIAGRAM
SEE INSTRUCTION MANUAL FOR DETAILS ON HOW
TO CONNECT THE ELECTRICAL COMPONENTS.
TRANSFORMER
E Green
F2a
FENWAL
L Black - 110 V
Blue
24 V
Red
WHITE
RODGERS
N White
TH
V1
Orange
Ignition +
Ionisation
V2
GND.
S 1.
Yellow/Green
Yellow/Green
White
Black HT Cable
Note:
If any of the original wire as supplied with the heater must be replaced, it must be replaced with 18AWG, 90ºC type UL
approved wire or its equivalent. If Transformer must be replaced, a UL approved model of similar type must be used.
20
www.bromicheating.com
WIRING DIAGRAM - FENWAL CONTROL, DUNGS GAS VALVE
ELECTRICAL DIAGRAM
SEE INSTRUCTION MANUAL FOR DETAILS ON HOW
TO CONNECT THE ELECTRICAL COMPONENTS.
TRANSFORMER
E Green
F2a
FENWAL
L Black - 110 V
Blue
24 V
Red
DUNGS
N White
TH
V1
Orange
Ignition +
Ionisation
V2
GND.
S 1.
Yellow/Green
Yellow/Green
White
Black HT Cable
Note:
If any of the original wire as supplied with the heater must be replaced, it must be replaced with 18AWG, 90ºC type UL
approved wire or its equivalent. If Transformer must be replaced, a UL approved model of similar type must be used.
www.bromicheating.com
21
REPLACEMENT PARTS
21
24
34
27
22
17
18
19
20
16
11
26
15
23
8
7
13
12
9
10
12
14
6
14
3
7
5
1
10
30
4
6
28
2
22
www.bromicheating.com
REPLACEMENT PARTS DESCRIPTION
No. Description
Part No. 300 Series
Part No. 500 Series
1
Glass Retainer - Top
BH8080002-1
BH8080003-1
2
Glass Retainer - Bottom
BH8080004
BH8080005
4
Glass
BH8080008
BH8080009
5
Reflector Assembly
BH8080018
BH8080019
6
Glass Retainer Side
BH8080020
BH8080020
7
Side Shield
BH8080021
BH8080021
8
Sail
BH8080022
BH8080023
BH8080024
BH8080025
BH8080026
BH8080027
BH8080030
BH8080030
BH8080010
BH8080011
3
9
Rear Housing
10
11
12
13
Rear Housing Mount (Lower)
Rear Cover Assembly
Rear Cover Mount
Burner
14
Wiring Harness + Ignitor Assembly- Honeywell
14
Wiring Harness + Ignitor Assembly- Fenwal
15
Inner Skin
BH8080028
BH8080029
16
Wall Bracket Assembly
BH8080001-1
BH8080001-1
17
Honeywall Control
BH8080015
BH8080015
18
Honeywell Gas Valve
BH8080014
BH8080014
19
20
21
Fenwal Control
Dungs 24V Gas Valve
WhiteRodger24VGas Valve
22
19mm ID Grommet
BH8080033
BH8080033
23
8mm ID Grommet
BH8080034
BH8080034
24
Gas Inlet Fitting (1/2” Gas Valve)
BH8080035
BH8080035
25
Gas Inlet Fitting (WhiteRodgers Gas Valve)
26
Gas Outlet Fittings (1/2”Gas Valve)
BH8080036
BH8080036
27
Gas Outlet Fitting (WhiteRodgers Gas Valve)
28
Manifold Assembly - Natural Gas
BH8080037
BH8080037
28
Manifold Assembly - LPG
BH8080093
BH8080090
29
Manifold Inlet Fitting
30
Injector (LPG)
BH8080016
BH8080016
30
Injector (NG)
BH8080017
BH8080017
31
Wall Bracket Replacement Screw Set including Gas Hose
BH8080051-1
BH8080051-1
32
Heater Replacement Screw Set
33
Deflector Screw Set including arm
BH8080052
BH8080052
34
Transformer – 110V-230V (Honeywall)
BH8080050
BH8080050
34
Transformer – 110V-24V (Fenwal)
Note: For more information on obtaining spare parts contact the place of purchase or
BROMIC HEATING
Head Office: 1 Suttor Street, Silverwater, Sydney, NSW 2128 Australia
Telephone: 1300 276 642 (within Australia) or +61 2 9748 3900 (from overseas) Fax: +61 2 9748 4289
Email: [email protected] Web: www.bromicheating.com
www.bromicheating.com
23
POST-INSTALLATION REPORT
POST-INSTALLATION REPORT
for Platinum Smart-Heat gas radiant heaters
AFTER HEATER INSTALLATION PLEASE PHOTOCOPY, COMPLETE, & SEND THIS REPORT BY:
FAX TO (02) 9748 4289 or BY MAIL TO Bromic Heating Pty Ltd, Suite 1305, 13223 Black Mountain Road
San Diego, California 92129 USA or SCAN AND EMAIL TO [email protected]
Customer Business Name:
Please fill in the relevant information or circle the
appropriate Yes/No responses below:
Date:
dd / mm / yyyy
Site Address:
Suburb:
State:
Postcode:
Customer Contact Details:
Name:
Position:
Ph: (
)
Fax: (
How many Platinum Smart-Heat
heaters are installed on this site?
3-Tile:
________
5-Tile:
________
What type of gas is used?
LPG
Natural
Gas
Is/Are the heater(s) exposed to
salt air or any other corrosive or
chemical atmosphere?
Yes
No
Does the heater(s’) installation
location pose a hazard to the site?
Yes
No
Do heater clearances match the
minimum requirements outlined
in the “Installation Requirements”
section of the Installation,
Operation and Service Manual?
Yes
No
Is the gas supply line adequately
sized for the number of heaters
installed?
Yes
No
Have gas lines been purged of air?
Yes
No
Have gas lines been checked for
leaks with a soapy water solution?
Yes
No
Was the heater field tested and
operated without malfunction?
Yes
No
What is the inlet gas supply
pressure?
_________ kPa
What is the gas valve outlet
pressure (at test point)?
_________ kPa
)
Mobile:
Installer Contact Details:
Name:
Position:
Ph: (
)
Fax: (
)
Mobile:
Signature of authorised person:
Name:
Company:
Date:
24
Position:
dd / mm / yyyy
www.bromicheating.com
TROUBLESHOOTING
SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
Heater will not turn on
1. No power
2. No gas
1. Have authorized electrician check
power supply
2. Have authorized gas fitter check
gas supply
Heater turns on, but then cycles on
and off
1. Insufficient flame on ionisation rod
2. Drafty conditions
3. Insufficient earth connection between
heater and control box
1.
No gas
1.
2.
3.
4.
Low ceramic tile surface temperature
1. Low manifold gas pressure
2. Low gas inlet pressure
3. Orifice partially blocked with foreign
matter
4. Combustion by-products not
adequately ventilated
5. Manifold misaligned from excessive
torque applied on pipe at installation
6. Gas supply piping too small
7. Foreign matter in venturi tube
1. Adjust valve regulator until 5”W.A
for natural gas, or 11” W.A for
propane is obtained
2. Adjust main supply regulator until
at least 6” W.C for natural gas or
11” W.C for propane precedes
heater’s control assembly
3. Clean orifice
4. Provide adequate ventilation of
by-products
5. Replace manifold
6. Increase gas pressure or replace
piping
7. Remove with bottle brush
Gas odour
1.
2.
3.
4.
5.
Loose pipe connection
Defective regulator
Defective manual shut-off valve
Defective gas control valve
Loose flexible hose
1. Check all connections with soap
solution and tighten where
necessary
2. Replace regulator
3. Replace manual shut-off valve
4. Replace gas control valve
5. Tighten flexible hose
Burning of gas/air mixture inside
burner casting (flashback)
1.
2.
3.
4.
Separation of ceramic tiles
Ceramic tile(s) cracked
Heater mounted at incorrect angle
Excessive drafts
1. Replace burner assembly
2. Replace burner assembly
3. Check angle of heater. See heater
nameplate.
4. Shield or relocate heater.
Control assembly is overheating
1. Heater not mounted correctly
Carbon formation on ceramic tile
surface of burner
1.
2.
3.
4.
Air in gas line
Manual shut-off valve closed
Regulator sticking
Regulator reversed
Misaligned orifice
Obstruction in venturi tube
Low gas pressure
Wrong gas supplied to heater
www.bromicheating.com
•
•
Check and set gas pressure
Check and clear obstruction to
burner venturi and injectors
2. Discontinue use in high winds
3. Replace wiring harness and clean
connections to ensure good
grounding
1.
2.
3.
4.
Purge line
Open valve
Replace regulator
Remove and install properly
1. Mount wall bracket / control
housing against a vertical flat
surface, following the instructions
outlined in the installation section
of this manual. Always use
supplied parts to mount heater.
1.
2.
3.
4.
Consult sales agent or factory
Clean with bottle brush
Provide required pressure
Check label for type of gas
required
25
APPENDIX A
26
www.bromicheating.com
APPENDIX A CONTINUED...
www.bromicheating.com
27

advertisement

Key Features

  • Electronic controls
  • Remote operation
  • Outdoor suitability
  • Wall or ceiling mounting
  • Safety features
  • Efficient heating

Frequently Answers and Questions

What types of gas are compatible with the Bromic Heating BH0110002-1?
The model can be configured for either natural gas or propane (LPG). Refer to the rating plate for specific gas type.
What is the maximum wind speed the heater can operate in?
The heater is designed for winds up to 10 mph. Performance may be affected in higher wind conditions.
What are the minimum mounting distances required?
Refer to the Installation Clearances section in the manual for specific distances based on whether a protective cover is used.

Related manuals

Download PDF

advertisement