PARADOX EB-N94 is an advanced intelligent PIR intrusion detector with dual sensors, digital signal processing, and advanced True Motion Recognition software. It delivers accurate intruder detection while minimizing false alarms caused by environmental changes or interference from pets. The EB-N94 offers two working modes, bus and relay, compatible with various control panels.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

PARADOX EB-N94 Installation Manual | Digital PIR Intrusion Detector | Manualzz
INSTALLATION GUIDE OF EB-N94 FOUR-ELEMENT
INTELLIGENT PIR INTRUSION DETECTOR
1.Brief Introduction
EB-N94 is a kind of PIR intrusion detector integrating the most
advance d security technology. It adopts 2 dual PIR sensors with
high accuracy, intelligent digi-tal chip, advanced ,<True Motion
Recognition & Anti-pests>of tware technology, which can help
it to make an accurate judgment of trueintruder or other interfer
-ence that can cause wrong alarm. And it is with function of auto
-matic memory of environmental change, which can avoid wro
-ng alarm a used by hot & cold air, opera-tion machine interfere
-nce. It can prevent effectively the interference cause by a 25 kg
past or 10 cats, insect, mouse, birds etc. Its super filter can be
used indoor and outdoor. This has clear various interference
that com-mon PIR detector can't overcome; and put an end to
wrong alarm and miss alarm .EB-N94 has two different working
modes: bus mode and relay mode, can be used for all kinds of
control panels on the market.
Lens
PIR
LED
Sensitivity adjust
Connect terminals
Code switch
Walk-test LED
Figure 1.General View
Figure 2.Inside View
2.Specifications
Anti -EMI/RFI 10V/m 10MHz-1000MHz
Motion test 0.2m/s-3.5m/s(0.6ft-11ft)
Accessories:
BR-1:Surface mounted swivel bracket,adjustable 30
down and 45 left/right.
Environmental:
Operating Temp: -10 C to 50 C(14 F to 122 F )
Humidity 5%-95% RH
Storage Temp :-20 C to 60 C (-4 F to 40 F)
Physical
Size(H*W*D):176*85*69mm
Models: EB-N94
Input Voltage 9-16VDC
Cyrrent Drain 30mA@ 12VDC
Detection Range 11.6m*11.6m
Alarm output NC.>100mA/28VDC
Anti white light resistance
>1000000LUX
Installation height:2m-2.7m
Top view
Tamper switch NC.100mA/28VDC
PIR Section:Lens Date
NO.of Curtain Beams (11+11+9)*2=62
Tripping Indication:
lndicator lights for about 10-30 seconds
This device is coherent to Europe parliament direct 1999/5/EC
necessary items and rules, and also coherent to the main spirits
of radio and telecom terminal equipments on March 9th . 1999.
The device also reaches the Canadian standard RSS-210. It can
be used indoor and outdoor, which can reach its maximum protection and avoidance of above interference.
Side view
3.Installation
3.1 General Guidelines
No direct facing cold
/hot source
No direct sun shine
Keep away from high
pressure power
No facing metal wall
Installation base
should be stable
3. 2Anti-pests installation
The upper part of the
detection area is non
anti-pests area
Never face the detector to
the place that pests can
climb up directly
Anti-pests weight 20Kg
The installation height
of the detector is 2.2-2.4
meters can Anti-pests
3.3Illustrated Installation Procedure
1 Open holes on base:
Bracket mounting
holes
A.Mask the drilling
porints and drill in the
the wall.
B.Route the cables
into the base via the
rear channel.
Corner mounting
holes
C.Insert two nails and
arrach the base to the
wall with two screws.
Wall mounting
holes
Cable hole
2
3 function of coding switch:
D.Insert the bottom
edge of the large PCB
under this tab&press
the top edge in.
Wire up the terminal block
EB-N94 has two different working modes:bus mode and relay mode,the mode choosing
can be conducted by DIP switch.
Relay mode the switch 1 of DIP=OFF
When setting to the relay mode EB-N94 transmits alarm and temper signal by relay as standard sensors, same as the figure, can be powered by contacted the power of panel and the
"RED","BLK" of the sensor,"GRN","YEL" unused, on rel ay mode, the setting only can
be am ended by DIP switch and trim pot-ntiometer
Bus mode the switch 1 of DIP=ON
When setting to bus mode EB-N94 transmits alarm, tamper signals and datas by bus,and setting the sensor as well. On bus mode, EB-N94 can be directly connected with control panel. same as the figure, can be pow-red by contacted the power of panel and the "RED","BLK" of
the sens-r,"GRN","YEL" connected with the correspondance terminals. On bus m-de,the setting can be amended by DIP switch and trim potentiometer, also can by system keypad(should be compated with system)get into programming mode.
Single or dual edge processing
This setting direct the DSP digital signal process working mode.Single side mode
is used the normal situation few of interference. Both sides process(out/in analysis )
mode can effectiv ely reduce fault alarm. So, we recommend use this working mode
when the sensor in stallated near interfere resource.
LED setting
LED light 5 second when detected the energy of the moving signal can result alarm enough,
when the energy of the signal not enough, LED blink.
4 Setting of coding switch:
EB-N94 PCB
Function
Work mode
Digital signal process
NC COM RED BLK GRN YEL TMP TMP
Alarm output
Power
Communicate Tamper
bus
When relay mode,
these two wires not
connect
LED
Moving signal instruct
Tamper confirm
Bus mode
Relay
Bus
Single side
Both sides
Invalid
Valid
Invalid
Valid
Invalid
Valid
Sensitivity
ZONE
AUX+ AUX- GRN YEL 24H/ZONE
Contral panel
Unused
Unused
001
001
001
1 =OFF
1 =ON
2 =OFF
001
001
2 =ON
3 =OFF
001
001
001
3 =ON
5 =OFF
5 =ON
002
001=010
Relay mode
DIP switch1=OFF
DIP switch1=ON
DIP switch2=OFF
DIP switch2=ON
DIP switch3=OFF
DIP switch3=ON
Unused
Unused
Unused
Unused
Trim potentiometer 0 10
5 Sensitivity adjustment:
The trim potentiometer will turn bigger when turn clockwise, reverse result
when turn counter-colockwise 0.25s-2s
6. PCB height setting
7. Motion test to protected area
The best operation height of
EB-N94 is 2.1 meter, a little
higher or loweris also permitted.
Confirm the adjustable height
mark on the right ups ide on c ove r
tally with the installation height.
If another installationheight is
needed, readjust the PCB in
accordance with your needs.
Motion test is necessarily
required inthe protection area in
order to confirm that areas need
pro-tection are within the prote
ctive area.
A. Install the cover, close the fastening position.
Guarantee that the front and back cover close
Tightly without any space or the looseness of
anti-water cover can't prevent humidity entering
into the parts.
B. Crossing to any direction of the detection area,
your walking will cause the L E D indicator to
light for 2-3 seconds (refer to the right diagram)
C. Perform motion test from contrary directions
in order to confirm the boundary of two sides.
Make c onfi rmed that detection center pointing to
the center of protected area.
4.Special comments
Even the most sophistic ated detcetors can some times be defeated or may fail to warn due to :DC power failure/improper connection, malicious masking
of the lens,tampering with the optical system, decreased sensitivity in ambient temperatures near that of the human body and unexpected failure of a
component part. The above list includes the most common reasons for failure recommended that the detector and the entire alarm system be checked
weekly, to ensure proper performance.An alarm system should not be regarded as a substitute for insurance. Home & property owners or renters shou ldbe
prudent enough to continue insuring their lives & property, even though they are protected by an alarm system.
This device has been tested and found to comply with the limits for a Class B digitaldevice, pursuant harmful interference in residential installations .This equipment
generates,us es and can radiate radio frequen cy energy and ,if not installed and used in accordance with the ins-tructions ,may cause harmful in-terference to radio and
television reception. However, there is no guarantee that interference will not occur in aparticular installation .If this device does cause such interference , which can be verfied
by turning the device off and on ,the user is encouraged to eliminate the interference by one or more of the followingmeasures:
WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could
void the user s authority to operate the equipment.
P/N 20605002A00

advertisement

Key Features

  • Dual PIR sensors
  • True Motion Recognition
  • Anti-pests
  • Bus & relay modes
  • Adjustable sensitivity
  • Tamper protection
  • Outdoor & indoor use
  • Anti-white light resistance

Frequently Answers and Questions

What is the detection range of the EB-N94?
The detection range is 11.6m x 11.6m.
What is the operating temperature range of the EB-N94?
The operating temperature range is -10°C to 50°C (14°F to 122°F).
How do I adjust the sensitivity of the EB-N94?
The sensitivity is adjustable using the trim potentiometer on the PCB. Turn clockwise to increase sensitivity and counter-clockwise to decrease sensitivity.
What are the different working modes of the EB-N94?
The EB-N94 has two working modes: bus mode and relay mode. The mode can be selected using the DIP switch on the PCB.
How do I install the EB-N94 to prevent false alarms from pests?
The upper part of the detection area is non-anti-pests area. Do not face the detector to the place that pests can climb up directly. An installation height of 2.2-2.4 meters can help prevent pest interference.