Paradox EB-N94 Installation Manual
PARADOX EB-N94 is an advanced intelligent PIR intrusion detector with dual sensors, digital signal processing, and advanced True Motion Recognition software. It delivers accurate intruder detection while minimizing false alarms caused by environmental changes or interference from pets. The EB-N94 offers two working modes, bus and relay, compatible with various control panels.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
INSTALLATION GUIDE OF EB-N94 FOUR-ELEMENT INTELLIGENT PIR INTRUSION DETECTOR 1.Brief Introduction EB-N94 is a kind of PIR intrusion detector integrating the most advance d security technology. It adopts 2 dual PIR sensors with high accuracy, intelligent digi-tal chip, advanced ,<True Motion Recognition & Anti-pests>of tware technology, which can help it to make an accurate judgment of trueintruder or other interfer -ence that can cause wrong alarm. And it is with function of auto -matic memory of environmental change, which can avoid wro -ng alarm a used by hot & cold air, opera-tion machine interfere -nce. It can prevent effectively the interference cause by a 25 kg past or 10 cats, insect, mouse, birds etc. Its super filter can be used indoor and outdoor. This has clear various interference that com-mon PIR detector can't overcome; and put an end to wrong alarm and miss alarm .EB-N94 has two different working modes: bus mode and relay mode, can be used for all kinds of control panels on the market. Lens PIR LED Sensitivity adjust Connect terminals Code switch Walk-test LED Figure 1.General View Figure 2.Inside View 2.Specifications Anti -EMI/RFI 10V/m 10MHz-1000MHz Motion test 0.2m/s-3.5m/s(0.6ft-11ft) Accessories: BR-1:Surface mounted swivel bracket,adjustable 30 down and 45 left/right. Environmental: Operating Temp: -10 C to 50 C(14 F to 122 F ) Humidity 5%-95% RH Storage Temp :-20 C to 60 C (-4 F to 40 F) Physical Size(H*W*D):176*85*69mm Models: EB-N94 Input Voltage 9-16VDC Cyrrent Drain 30mA@ 12VDC Detection Range 11.6m*11.6m Alarm output NC.>100mA/28VDC Anti white light resistance >1000000LUX Installation height:2m-2.7m Top view Tamper switch NC.100mA/28VDC PIR Section:Lens Date NO.of Curtain Beams (11+11+9)*2=62 Tripping Indication: lndicator lights for about 10-30 seconds This device is coherent to Europe parliament direct 1999/5/EC necessary items and rules, and also coherent to the main spirits of radio and telecom terminal equipments on March 9th . 1999. The device also reaches the Canadian standard RSS-210. It can be used indoor and outdoor, which can reach its maximum protection and avoidance of above interference. Side view 3.Installation 3.1 General Guidelines No direct facing cold /hot source No direct sun shine Keep away from high pressure power No facing metal wall Installation base should be stable 3. 2Anti-pests installation The upper part of the detection area is non anti-pests area Never face the detector to the place that pests can climb up directly Anti-pests weight 20Kg The installation height of the detector is 2.2-2.4 meters can Anti-pests 3.3Illustrated Installation Procedure 1 Open holes on base: Bracket mounting holes A.Mask the drilling porints and drill in the the wall. B.Route the cables into the base via the rear channel. Corner mounting holes C.Insert two nails and arrach the base to the wall with two screws. Wall mounting holes Cable hole 2 3 function of coding switch: D.Insert the bottom edge of the large PCB under this tab&press the top edge in. Wire up the terminal block EB-N94 has two different working modes:bus mode and relay mode,the mode choosing can be conducted by DIP switch. Relay mode the switch 1 of DIP=OFF When setting to the relay mode EB-N94 transmits alarm and temper signal by relay as standard sensors, same as the figure, can be powered by contacted the power of panel and the "RED","BLK" of the sensor,"GRN","YEL" unused, on rel ay mode, the setting only can be am ended by DIP switch and trim pot-ntiometer Bus mode the switch 1 of DIP=ON When setting to bus mode EB-N94 transmits alarm, tamper signals and datas by bus,and setting the sensor as well. On bus mode, EB-N94 can be directly connected with control panel. same as the figure, can be pow-red by contacted the power of panel and the "RED","BLK" of the sens-r,"GRN","YEL" connected with the correspondance terminals. On bus m-de,the setting can be amended by DIP switch and trim potentiometer, also can by system keypad(should be compated with system)get into programming mode. Single or dual edge processing This setting direct the DSP digital signal process working mode.Single side mode is used the normal situation few of interference. Both sides process(out/in analysis ) mode can effectiv ely reduce fault alarm. So, we recommend use this working mode when the sensor in stallated near interfere resource. LED setting LED light 5 second when detected the energy of the moving signal can result alarm enough, when the energy of the signal not enough, LED blink. 4 Setting of coding switch: EB-N94 PCB Function Work mode Digital signal process NC COM RED BLK GRN YEL TMP TMP Alarm output Power Communicate Tamper bus When relay mode, these two wires not connect LED Moving signal instruct Tamper confirm Bus mode Relay Bus Single side Both sides Invalid Valid Invalid Valid Invalid Valid Sensitivity ZONE AUX+ AUX- GRN YEL 24H/ZONE Contral panel Unused Unused 001 001 001 1 =OFF 1 =ON 2 =OFF 001 001 2 =ON 3 =OFF 001 001 001 3 =ON 5 =OFF 5 =ON 002 001=010 Relay mode DIP switch1=OFF DIP switch1=ON DIP switch2=OFF DIP switch2=ON DIP switch3=OFF DIP switch3=ON Unused Unused Unused Unused Trim potentiometer 0 10 5 Sensitivity adjustment: The trim potentiometer will turn bigger when turn clockwise, reverse result when turn counter-colockwise 0.25s-2s 6. PCB height setting 7. Motion test to protected area The best operation height of EB-N94 is 2.1 meter, a little higher or loweris also permitted. Confirm the adjustable height mark on the right ups ide on c ove r tally with the installation height. If another installationheight is needed, readjust the PCB in accordance with your needs. Motion test is necessarily required inthe protection area in order to confirm that areas need pro-tection are within the prote ctive area. A. Install the cover, close the fastening position. Guarantee that the front and back cover close Tightly without any space or the looseness of anti-water cover can't prevent humidity entering into the parts. B. Crossing to any direction of the detection area, your walking will cause the L E D indicator to light for 2-3 seconds (refer to the right diagram) C. Perform motion test from contrary directions in order to confirm the boundary of two sides. Make c onfi rmed that detection center pointing to the center of protected area. 4.Special comments Even the most sophistic ated detcetors can some times be defeated or may fail to warn due to :DC power failure/improper connection, malicious masking of the lens,tampering with the optical system, decreased sensitivity in ambient temperatures near that of the human body and unexpected failure of a component part. The above list includes the most common reasons for failure recommended that the detector and the entire alarm system be checked weekly, to ensure proper performance.An alarm system should not be regarded as a substitute for insurance. Home & property owners or renters shou ldbe prudent enough to continue insuring their lives & property, even though they are protected by an alarm system. This device has been tested and found to comply with the limits for a Class B digitaldevice, pursuant harmful interference in residential installations .This equipment generates,us es and can radiate radio frequen cy energy and ,if not installed and used in accordance with the ins-tructions ,may cause harmful in-terference to radio and television reception. However, there is no guarantee that interference will not occur in aparticular installation .If this device does cause such interference , which can be verfied by turning the device off and on ,the user is encouraged to eliminate the interference by one or more of the followingmeasures: WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. P/N 20605002A00
advertisement
Key Features
- Dual PIR sensors
- True Motion Recognition
- Anti-pests
- Bus & relay modes
- Adjustable sensitivity
- Tamper protection
- Outdoor & indoor use
- Anti-white light resistance
Frequently Answers and Questions
What is the detection range of the EB-N94?
The detection range is 11.6m x 11.6m.
What is the operating temperature range of the EB-N94?
The operating temperature range is -10°C to 50°C (14°F to 122°F).
How do I adjust the sensitivity of the EB-N94?
The sensitivity is adjustable using the trim potentiometer on the PCB. Turn clockwise to increase sensitivity and counter-clockwise to decrease sensitivity.
What are the different working modes of the EB-N94?
The EB-N94 has two working modes: bus mode and relay mode. The mode can be selected using the DIP switch on the PCB.
How do I install the EB-N94 to prevent false alarms from pests?
The upper part of the detection area is non-anti-pests area. Do not face the detector to the place that pests can climb up directly. An installation height of 2.2-2.4 meters can help prevent pest interference.