Froggit DP35 Manual

Froggit DP35 Manual

The Froggit DP35 is a wired temperature sensor with a 3m cable. It measures temperature and transmits readings every 77 seconds. The device is waterproof, has an LCD display for current readings, and can be paired with a DP1500 Wi-Fi gateway or weather station console for remote monitoring and data visualization.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Froggit DP35 Manual - Wired Temperature Sensor | Manualzz
DP35
Cabled temperature sensor
Manual (EN)
Support/updates/manuals/spare parts/compatible products:
www.froggit.de / [email protected]
1
Overview
Figure 1: Cabled temperature sensor
Temperature sensor:




Measures temperature with a 3m wired sensor.
Transmits readings every 77 seconds.
Waterproof according to IP65.
LCD display for current reading.
When paired with a DP1500 Wi-Fi
Wi
gateway:



Displays temperature readings on the live data page of the WS View app
(requires the DP1500 and your smartphone to use the same Wi-Fi
Wi network).
Up to 8 channels are supported. The channel names can be edited in the app.
Battery level information is displayed in the WS View app.
When paired with a weather station console (HP1000SE PRO series / WH3900):

Real-time
time temperature data shown on the display (HP1000SE PRO series
only).
2




Up to 8 channels are supported. The channel names can be edited on the
console.
Use of Ecowitt Weather Server:View
Server:View current temperature data, historical
records and graphs on the website.
Receive email alerts from the server.
Remote monitoring with smartphone, laptop or computer by visiting the
website.
Setup (commissioning):
Inserting the battery
1. remove the battery compartment on the back of the transmitter by removing
the screw (see figure 2):
Figure 2: Inserting the battery
2. insert a 1.5 V AA battery (pay attention to the polarity: the flat side of the
battery must be against the spring side of the battery compartment).
The temperature reading is immediately displayed on the LCD screen and is
normally updated every 77 seconds (the sensor transmission update period).
Note: If no reading is displayed on the screen, make sure the battery is
inserted correctly or a proper reset has been performed. Make sure the battery
is inserted correctly. Do not insert the battery upside down.
3. close the battery cover
3
Placement of the sensor:
To mount the unit on a wall or wooden beam:

Use a screw (screw ST D3.2*M2.0*6) to fix the bracket to the wall, then pass
pa
the probe through the hole in the bracket as shown in Figure 3:
Figure 3

Attach the sensor to the bracket with the M12 hex nut and tighten the screw as
shown in figure 4: (Turn the nut by hand until it is tight, then use a spanner to
turn 1/3 to 1/2 turn and no more. Do not over tighten).
Figure 4
4
For attaching the unit to a pole (not included in the scope of delivery) with the
supplied hose clamp:
Figure 5
Wi-Fi
Fi Configuration:
To view sensor data on your mobile app and receive email alerts on our
weather server, you need to pair this device with our froggit DP1500 or our
ou
HP1000SE PRO Series / WH3900 weather station (each sold separately).
Pairing with froggit DP1500:
If the DP1500 has already been in use and you have never set up a DP35
sensor before, simply switch on the sensor and the DP1500 will automatically
accept the sensor data.
Note: The DP1500 can support up to 8 DP35 temperature sensors. Each new
sensor will be recognised as a new channel according to the power-up
power
sequence. You can assign a label to the channel on each sensor to distinguish
5
it. The channel name can be edited both in the app and on ecowitt.net (the
name edited in the app is not synchronised with
with the ecowitt.net website and
should be edited separately on the device setup page on ecowitt.net).
If you want to use a new DP35 sensor to replace the old one (which is already
configured on a specific channel), please try the following:
1. open the Sensorr ID page in the WS View app and locate your old sensor ID.
Switch off the old sensor and switch on the new sensor. 3.
On the Sensor ID page, click 'Register New'.
The new sensor will then be enrolled and the old sensor will be deleted.
View online data with
wi WS View:
When the Wi-Fi
Fi configuration is complete (to tell the DP1500 to connect to
your Wi-Fi
Fi network), your sensor data and the sensor's battery voltage
information will be displayed in the WS View app on the Live Data page.
Note: Your smartphone and the DP1500 must be on the same network when
viewing live data from your sensor in the WS View App. Live data refers to
actual data received from the DP1500 and is not stored in the WS View App.
However, the data is always transferred to and stored in the www.ecowitt.net
w
Cloud (under your registered account, and you can access it at any time via
your browser).
Set email alerts:
Once your device has been successfully added to the Ecowitt weather server,
you can set alerts for the sensor on the website to receive
receive email notifications.
6



Specifications:
Power supply: 1x1.5V AA battery (not included).
Sensor type: epoxy sealed thermistor or NTC
Frequency: 868 MHz
Caution !
This booklet may contain errors or misprints. The information is contains is regularly c
hecked and correction are included in subsequence editions.
We disclaim any responsibility for any printing error, or their consequences.
consequences
The specification of this product may change without prior notice.
7
Gerneral safety insructions
Danger of asphyxiation:
Keep all packaging materials (plastic bags, rubber bands, etc.) away from children.
There is a danger of suffocation!
Danger of burns:
Caution! Leaking / leaking battery acid can lead to burns! Avoid contact of battery
acid with eyes, mucous membranes and skin. In case of contact, rinse the affected
areas immediately with clear water and consult a doctor.
Risk of electric shock:
Children must not be unattended with the device, because the device contains
electronic parts which are operated by means of a power source. The device may
only be used as described in the instructions. If not, there is a risk of electric shock.
Danger of fire & explosion:
Use only recommended batteries. Never short-circuit the unit or batteries. Never
throw the device or batteries into a fire! Overheating and improper handling may
result in short circuits which can cause fires and explosions.
Important:
If there is a defect, contact your dealer immediately. Never disassemble the device!
The dealer will contact the service department. Never expose the device to water!
Protect the device from vibrations. Only use recommended batteries. Never mix
batteries - Always replace empty batteries with a complete set of full power batteries.
If the unit is not powered for a longer period of time or is not in use, remove the
batteries from the unit. The manufacturer accepts no liability for incorrectly inserted
batteries
Notes on the return of batteries according to §12 BatterieVO: Batteries do not belong
in the household waste. Please dispose of all batteries as required by law, disposal in
domestic waste is expressly prohibited. Batteries and rechargeable batteries can be
dispensed free of charge at municipal collection points or in the shops on the spot.
This manual may not be reproduced in any form without the written permission of the
publisher, even in excerpts.
This manual may contain errors and misprints. However, the information in this
8
manual is regularly reviewed and corrections made in the next issue. We accept no
liability for technical errors or printing errors, and their consequences.
All trademarks and copyrights are acknowledged.
www.froggit.de
HS Group GmbH & Co. KG
Escherstr.31
50733 Koeln
Germany
Telefon
0221 / 367 48 05
E-Mail
[email protected]
Registergericht Amtsgericht
Koeln HRA 26493
Komplementaer: HS Group
Verwaltungsgesellschaft mbH
Sitz Koeln
Registergericht Amtsgericht
Koeln HRB 64734
Geschaeftsfuehrer: Peter
Haefele, Carl Schulte
UStId DE237971721
WEEE Reg. Nr. 66110125
declaration of conformity
Hereby we declare, HS-Group GmbH & Co.KG, Escherstr. 31, 50733 D-Cologne,
that this product is in compliance with the essential requirements and other relevant
provisions of Directive 2014/53/EU.
The declaration of conformity for this product can be found at: www.froggit.de or on
request.
9

advertisement

Key Features

  • Wired temperature sensor
  • 3m cable
  • Waterproof (IP65)
  • LCD display
  • Wireless data transmission
  • Compatible with DP1500 gateway and HP1000SE PRO/WH3900 weather stations
  • Remote monitoring with smartphone/computer
  • Email alerts
  • Historical data recording

Frequently Answers and Questions

How often does the DP35 sensor transmit readings?
It transmits readings every 77 seconds.
What is the maximum number of DP35 sensors I can use with the DP1500 gateway?
You can use up to 8 DP35 sensors with the DP1500 gateway.
Can I view historical temperature data from the DP35 sensor?
Yes, you can view historical data on the Ecowitt website.
How do I mount the DP35 sensor on a wall?
Use the provided bracket and screw to mount the sensor on a wall or wooden beam.
How do I replace an old DP35 sensor with a new one?
Follow the instructions in the manual to register a new sensor and delete the old one.

Related manuals

Download PDF

advertisement