E2S DL112HDC024 Instructions/Service Manual
The E2S DL112HDC024 is a combined metal sounder and LED beacon designed for visual and audible alarm signaling. It operates on 24V DC and features adjustable flash patterns and a variety of tone options, making it suitable for various applications requiring both visual and audible warnings. The device is IP66 rated and offers a wide operating temperature range, ensuring reliable performance in diverse environments.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
12
INSTRUCTION & SERVICE MANUAL DL112H AlertAlight Combined Metal Sounder LED Beacons • • • • -2 °C to + C (-13°F to 131°F) Type 4 / 4X / 3R / 13, IP66 1.8Kg (3.96lb) CE, All units UL Listed. Voltage Range Nominal Sounder Current* Nominal Beacon Current* 12 V dc 10-14Vdc 200mA 79. mA 24V dc 16-30Vdc 200mA 86. mA DL112HDC048 48V dc 42- 4Vdc 120mA 60mA DL112HAC230 11 V ac 11 V ac ± 10% 100mA 34mA DL112HAC230 230V ac 230V ac ± 10% 60mA 18. mA Unit Type Code Nominal Voltage # Nominal SPL Max SPL 103dB(A) Tone 44 @ 1m 119dB(A) Tone 4 @ 1m DL112HDC024 *Nominal current at nominal voltage, Tone 12 / 1Hz Flash Pattern; #Factory Default setting 24Vdc, beacon customer settable to 12Vdc mm 0.4Nm AC: 1.0 – 2. mm2 / AWG18 AWG12 0. 2. –mm DC: 0.2 – 2. mm2 / AWG24 – AWG12 Attention: Installation must be carried out by an electrician in compliance with the latest codes and regulations. Attention: L'installation doit être effectuée par un électricien conformément aux derniers codes et réglementations. Achtung: Die Installation muss von einem Elektriker gemäß den neuesten Vorschriften und Bestimmungen durchgeführt werden. Attenzione: L'installazione deve essere eseguita da un elettricista in conformità con i codici e le normative più recenti. Atención : La instalación debe ser realizada por un electricista de acuerdo con los últimos códigos y regulaciones. Atenção: A instalação deve ser realizada por um eletricista de acordo com os códigos e regulamentos mais recentes. Внимание : установка должна выполняться электриком в соответствии с последними нормами и правилами. Attention: Disconnect from power source before installation or service to prevent electric shock Attention: Débranchez-le de la source d'alimentation avant l'installation ou l'entretien pour éviter tout choc électrique. Achtung: Vor Installation oder Wartung von der Stromquelle trennen, um einen Stromschlag zu vermeiden. Attenzione: scollegare dall'alimentazione prima dell'installazione o dell'assistenza per evitare scosse elettriche. Atención : desconéctelo de la fuente de alimentación antes de la instalación o el servicio para evitar descargas eléctricas. Atenção: Desconecte da fonte de alimentação antes da instalação ou serviço para evitar choque elétrico Внимание : отключите от источника питания перед установкой или обслуживанием, чтобы предотвратить поражение электрическим током. E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH [email protected] e2s.com D173-00-201-IS Issue 4 19/11/2021 AC (See D173-06-20 ) E L N C S2 S3 S1 E NL LNE S1 DC + - S2 S3 (See D173-06-201) L3 S1 E - + + - E S1 (AC & DC, See Tone Table) Reverse Polarity Switching - On DC versions the second stage alarm tone can be selected by reversing the polarity of the Default = S1 - Tone 1 supply voltage if switch 6 is in the ON position if Link LK3 is present. (ON = 1, OFF = 0) E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH [email protected] e2s.com D173-00-201-IS Issue 4 19/11/2021 INSTRUCTION & SERVICE MANUAL DL112H AlertAlight Combined Metal Sounder LED Beacons 267. mm 10. 4 in. 130.0mm .12 in. 4x 1.5Nm 90.0mm 3. 6.7mm 0.27 in. in. 9.7mm 0.38 in. 2 OFF M20 X 1. THREADED CABLE ENTRIES 147.0mm .79 in. For DL112HDC units, using a ring terminal, fit an Earth to the shown location underneath the M4 screw and M4 spring washer. This point shall not be used for any other purpose (e.g. ground bonding). E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH [email protected] e2s.com D173-00-201-IS Issue 4 19/11/2021 S1 - LED Flash Mode Settings (AC & DC) The Flash Mode Dip Switch can be changed to set the desired flash pattern ON 1 2 3 Flash Mode DIP Switch – Shown with 1-OFF, 2-ON, 3-OFF (0 1 0), This denotes Flash mode 1Hz. For further flash modes refer to table: Switch Setting Flash Mode 000 Steady on 100 Blinking 010 Flashing 1Hz* 110 Flashing 1. Hz* 001 Flashing - Double Strike 101 Flashing - Triple Strike 011 Flashing 2Hz* 111 Flashing - Temporal • All models are approved for use as Audible Signal and Visual Appliance for use as General Signaling: UL464A & CSA C22.2 No 20 -17, UL1638A • Type 4 / 4X / 3R / 13, IP66 • -2 °C to + °C / -13°F to +131°F • To maintain Ingress Protection, cable entries must be fitted with suitably rated cable glands or stopping plugs • Units can be mounted using the 2-off 10 x 7mm obround holes in the mounting lugs. • EOL Monitoring (DC Only): End of Line Devices may be fitted between the +ve & -ve terminals of the PCBA. Please ensure that the device legs meet the wire size range stated for the connection terminals and are fitted correctly in order to avoid a short. Refer to the compatible control panel specification for EOL device values and ratings Nominal Operating Current# Model Nominal* Voltage Voltage Range Beacon Sounder 12V dc 10-14Vdc 79. mA 200mA 24V dc 16-30Vdc 86. mA 200mA DL112HDC048 48V dc 48-60Vdc 60mA 120mA DL112HAC11 11 V ac 11 V ac ± 10% 0/60Hz 34mA 100mA DL112HAC230 230V ac 230V ac ± 10% 0/60Hz 19mA 60mA DL112HDC024 *Nominal Voltage, 1Hz Flash Pattern & Tone 12; #Worst-case input voltage and worst case flash pattern Warnings Attention: Installation must be carried out by an electrician in compliance with the National Electrical Code, NFPA 70 or CSA 22.1 Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, Section 32. / L'installation doit exclusivement être réalisée par du personnel qualifié, conformément au code national d'électricité américain, NFPA 70 ou CSA 22.1 Code canadien de l'électricité, première partie, norme de sécurité relative aux installations électriques, Section 32 Attention: Disconnect from power source before installation or service to prevent electric shock / Débranchez-le de la source d'alimentation avant l'installation ou l'entretien pour éviter tout choc électrique. Attention: Do not paint / Ne pas Peinturer E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH [email protected] e2s.com D173-00-201-IS Issue 4 19/11/2021 INSTRUCTION & SERVICE MANUAL DL112H AlertAlight Combined Metal Sounder LED Beacons Stage 1 Set DIP SW 1 Tone No. 1 1 2 3 4 6 7 8 9 10 11 12 13 14 1 16 17 18 19 20 21 22 23 24 2 26 27 28 29 30 31 32 33 34 3 36 37 38 39 40 41 42 43 44 4 Tone Description Tone Visual 340Hz Continuous 800/1000Hz @ 0.2 s Alternating 00/1200Hz @ 0.3Hz 0. s Slow Whoop 800/1000Hz @ 1Hz Sweeping 2400Hz Continuous 2400/2900Hz @ 7Hz Sweeping 2400/2900Hz @ 1Hz Sweeping 00/1200/ 00Hz @0.3Hz Sweeping 1200/ 00Hz @ 1Hz DIN / PFEER P.T.A.P 2400/2900Hz @ 2Hz Alternating 1000Hz @ 1Hz Intermittent 800/1000Hz @ 0.87 Hz Alternating 2400Hz @ 1Hz Intermittent 800Hz @ 0.2 s on, 1s off Intermittent 800Hz Continuous 660Hz 1 0ms on, 1 0ms off Intermittent 44Hz (100ms)/440Hz (400ms) NNF S 32 001 660Hz 1.8s on, 1.8s off Intermittent 1.4KHz 1.6KHz 1s, 1.6KHz 1.4KHz 0. s NFC48 26 660Hz Continuous 4/440Hz @ 1Hz Alternating 44Hz @ 0.87 s Intermittent 800Hz @ 2Hz Intermittent 800/1000Hz @ 0Hz Sweeping 2400/2900Hz @ 0Hz Sweeping Bell 4Hz Continuous 440Hz Continuous 800/1000Hz @ 7Hz Sweeping 300Hz Continuous 660/1200Hz @ 1Hz Sweeping Two Tone Chime 74 Hz @ 1Hz Intermittent 1000 & 2000Hz @ 0. s Alternating Singapore 420Hz @ 0.62 s Australian Alert 00 1200Hz 3.7 s/0.2 s Australian Evacuation 1000Hz Continuous PFEER Toxic Gas 2000Hz Continuous 800Hz 0.2 s on, 1s off Intermittent 44Hz (100ms) / 440Hz (400ms) NF S 32 001 Motor Siren Slow rise to 1200Hz Motor Siren Slow rise to 800Hz 1200Hz Continuous Motor Siren Slow rise to 2400Hz 1KHz 1s on, 1s off Intermittent PFEER Gen. Alarm SW1 Setting 1234 6 000000 100000 010000 110000 001000 101000 011000 111000 000100 100100 010100 110100 001100 101100 011100 111100 000010 100010 010010 110010 001010 101010 011010 111010 000110 100110 110110 001110 101110 011110 111110 000001 100001 010001 110001 001001 101001 011001 111001 000101 100101 010101 110101 Stage 2 Tone (S2) 2 17 2 6 3 7 10 2 1 7 2 4 1 4 2 18 2 2 2 2 2 2 6 29 29 2 26 2 7 2 26 26 2 38 36 3 9 34 23 31 2 2 2 2 38 Stage 3 Tone (S3 20 2 27 1 1 4 4 4 17 27 34 Note: Please check factory settings and ensure the correct alarm tone is selected for your country or application E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH [email protected] e2s.com D173-00-201-IS Issue 4 19/11/2021 3 E N/L/+ DATE SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED 7 8 A ISSUE MOD No. 9 10 REASON - INITIAL - DATE INTRODUCTION RSR - 20/12/2021 E N/L/+ Stage 3 -ve Stage 2 -ve Stage 1 +ve OUT Stage 1 -ve OUT S3 L/+ N/E A3 C B A G F ALERTALARM RANGE STANDARDS R.N.POTTS APPROVED B.ISARD CHECKED DRAWING TO BS8888:2000 DRAWN GEOMETRIC TOLERANCES TO ISO1101:1983 LINEAR DIMENSIONAL TOLS R.S.RAIT ANGULAR DIMENSIONAL TOLS Stage 1 +ve IN 20/12/2021 DATE 20/12/2021 DATE 20/12/2021 ALTERNATIVE MATERIAL MATERIAL SURFACE FINISH WEIGHT (Kg) + + C EUROPEAN SAFETY SYSTEMS LTD. AS PER LATEST DATE OF ISSUE SHOWN ABOVE THIS DRAWING AND ANY INFORMATION OR DESCRIPTIVE MATTER THEREIN IS COMMUNICATED IN CONFIDENCE AND IS THE COPYRIGHT PROPERTY OF EUROPEAN SAFETY SYSTEMS LTD. NEITHER THE WHOLE OR ANY EXTRACT MAY BE DISCLOSED, LOANED, COPIED OR USED FOR MANUFACTURING OR TENDERING PURPOSES WITHOUT THEIR WRITTEN CONSENT. WWW.E2S.COM EUROPEAN SAFETY SYSTEMS LTD IMPRESS HOUSE MANSELL ROAD ACTON LONDON W3 7QH 2S warning signals Common +ve SHEET NTS 1 OF 2 SCALE D173-06-251 DRAWING NUMBER SOUNDER & LED WIRING DIAGRAMS TITLE DL112H DC COMBINED IF IN DOUBT, ASK DO NOT SCALE ALL DIMENSIONS IN MM + + - Stage 1 -ve - S2 - S2 G F E S3 6 Linked Sounder & Beacon Activation (Default) Config.: 1a Two/Three Stage Sounder Configuration Config.: 1b Stage 1: Apply Power to Common +ve & Stage 1 -ve Stage 2: Apply Power to Common +ve & Stage 1 -ve & connect Stage 2 -ve to Stage 1 -ve Stage 3: Apply Power to Common +ve & Stage 1 -ve & connect Stage 3 -ve to Stage 1 -ve 5 E L/+ N/E 4 D Stage 1 -ve IN Stage 1 +ve OUT Stage 1 -ve OUT Single Stage Configuration Stage 1: Apply Power to Stage 1 +ve & Stage 1 -ve WIRING LINKING BEACON & SOUNDER FACTORY FITTED 2 D C B A 1 3 E N/L/+ DATE SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED 7 8 A ISSUE MOD No. 9 10 REASON - INITIAL - DATE INTRODUCTION RSR - 20/12/2021 +ve OUT -ve OUT E N/L/+ Stage 3 -ve Stage 2-ve +ve IN -ve IN S3 L/+ N/E G F ALERTALARM RANGE STANDARDS R.N.POTTS APPROVED B.ISARD CHECKED DRAWING TO BS8888:2000 DRAWN GEOMETRIC TOLERANCES TO ISO1101:1983 LINEAR DIMENSIONAL TOLS R.S.RAIT ANGULAR DIMENSIONAL TOLS Stage 1 + IN Stage 1 + OUT 20/12/2021 DATE 20/12/2021 DATE 20/12/2021 ALTERNATIVE MATERIAL MATERIAL SURFACE FINISH WEIGHT (Kg) + + - - S2 C EUROPEAN SAFETY SYSTEMS LTD. AS PER LATEST DATE OF ISSUE SHOWN ABOVE THIS DRAWING AND ANY INFORMATION OR DESCRIPTIVE MATTER THEREIN IS COMMUNICATED IN CONFIDENCE AND IS THE COPYRIGHT PROPERTY OF EUROPEAN SAFETY SYSTEMS LTD. NEITHER THE WHOLE OR ANY EXTRACT MAY BE DISCLOSED, LOANED, COPIED OR USED FOR MANUFACTURING OR TENDERING PURPOSES WITHOUT THEIR WRITTEN CONSENT. WWW.E2S.COM EUROPEAN SAFETY SYSTEMS LTD IMPRESS HOUSE MANSELL ROAD ACTON LONDON W3 7QH 2S warning signals Common +ve IN Common +ve OUT Stage 1 -ve OUT Stage 1 -ve IN SHEET NTS 2 OF 2 SCALE D173-06-251 DRAWING NUMBER SOUNDER & LED WIRING DIAGRAMS TITLE DL112H DC COMBINED IF IN DOUBT, ASK DO NOT SCALE ALL DIMENSIONS IN MM + + - - S2 A3 +ve OUT -ve OUT C B A G F E S3 6 Independent Sounder & Beacon Activation (Remove Link Wires) Config.: 2a Two/Three Stage Sounder Configuration Config.: 2b Stage 1: Apply Power to Common +ve & Stage 1 -ve Stage 2: Apply Power to Common +ve & Stage 1 -ve & connect Stage 2 -ve to Stage 1 -ve Stage 3: Apply Power to Common +ve & Stage 1 -ve & connect Stage 3 -ve to Stage 1 -ve 5 E L/+ N/E 4 D Stage 1 - OUT Stage 1 - IN +ve IN -ve IN Single Stage Configuration Stage 1: Apply Power to Stage 1 +ve & Stage 1 -ve 2 D C B A 1 G F E D C B A 3 WIRING LINKING BEACON & SOUNDER FACTORY FITTED 2 ALERTALARM RANGE STANDARDS R.N.POTTS APPROVED B.ISARD CHECKED DRAWING TO BS8888:2000 DRAWN GEOMETRIC TOLERANCES TO ISO1101:1983 LINEAR DIMENSIONAL TOLS R.S.RAIT ANGULAR DIMENSIONAL TOLS Earth 20/12/2021 DATE 20/12/2021 DATE 20/12/2021 L/+ N/E 4 ALTERNATIVE MATERIAL MATERIAL 5 6 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED 7 8 A ISSUE MOD No. 9 EUROPEAN SAFETY SYSTEMS LTD. AS PER LATEST DATE OF ISSUE SHOWN ABOVE WWW.E2S.COM EUROPEAN SAFETY SYSTEMS LTD IMPRESS HOUSE MANSELL ROAD ACTON LONDON W3 7QH 2S warning signals Earth Stage 1 Live IN Stage 1 Neutral IN THIS DRAWING AND ANY INFORMATION OR DESCRIPTIVE MATTER THEREIN IS COMMUNICATED IN CONFIDENCE AND IS THE COPYRIGHT PROPERTY OF EUROPEAN SAFETY SYSTEMS LTD. NEITHER THE WHOLE OR ANY EXTRACT MAY BE DISCLOSED, LOANED, COPIED OR USED FOR MANUFACTURING OR TENDERING PURPOSES WITHOUT THEIR WRITTEN CONSENT. C E N/L/+ Stage 3 Stage 2 Common Stage 1 Live OUT Stage 1 Neutral OUT S3 L/+ N/E A3 Config.: 1b SHEET NTS 1 OF 2 SCALE D173-06-255 DRAWING NUMBER SOUNDER & LED WIRING DIAGRAMS TITLE DL112H AC COMBINED IF IN DOUBT, ASK DO NOT SCALE ALL DIMENSIONS IN MM E E L L N N C S2 10 REASON - INITIAL - DATE INTRODUCTION RSR - 20/12/2021 Linked Sounder & Beacon Activation (Default) Config.: 1a Two/Three Stage Sounder Configuration Stage 1: Apply Power to Live & Neutral Stage 2: Apply Power to Live & Neutral & connect Stage 2 to Common Stage 3: Apply Power to Live & Neutral & connect Stage 3 to Common SURFACE FINISH WEIGHT (Kg) E E L L N C N DATE S3 S2 Stage 1 Live IN E N/L/+ Stage 1 Neutral IN Stage 1 Live OUT Stage 1 Neutral OUT Single Stage Configuration Stage 1: Apply Power to Stage 1 Live & Stage 1 Neutral 1 G F E D C B A G F E D C B A 2 3 ALERTALARM RANGE STANDARDS R.N.POTTS APPROVED B.ISARD CHECKED DRAWING TO BS8888:2000 DRAWN GEOMETRIC TOLERANCES TO ISO1101:1983 LINEAR DIMENSIONAL TOLS R.S.RAIT ANGULAR DIMENSIONAL TOLS Stage 1 Live IN Stage 1 Live OUT Earth Stage 1 Neutral OUT Stage 1 Neutral IN Earth Neutral IN Live IN 20/12/2021 DATE 20/12/2021 DATE 20/12/2021 DATE Single Stage Configuration Stage 1: Apply Power to Stage 1 Live & Stage 1 Neutral 1 S3 6 7 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED C EUROPEAN SAFETY SYSTEMS LTD. AS PER LATEST DATE OF ISSUE SHOWN ABOVE 8 WWW.E2S.COM EUROPEAN SAFETY SYSTEMS LTD IMPRESS HOUSE MANSELL ROAD ACTON LONDON W3 7QH 2S warning signals Stage 1 Live IN Stage 1 Live OUT Earth Stage 1 Neutral OUT Stage 1 Neutral IN Stage 3 Stage 2 Common Earth Neutral IN Live IN THIS DRAWING AND ANY INFORMATION OR DESCRIPTIVE MATTER THEREIN IS COMMUNICATED IN CONFIDENCE AND IS THE COPYRIGHT PROPERTY OF EUROPEAN SAFETY SYSTEMS LTD. NEITHER THE WHOLE OR ANY EXTRACT MAY BE DISCLOSED, LOANED, COPIED OR USED FOR MANUFACTURING OR TENDERING PURPOSES WITHOUT THEIR WRITTEN CONSENT. Live OUT Neutral OUT Earth ALTERNATIVE MATERIAL MATERIAL 5 A ISSUE MOD No. 9 S3 Config.: 2b SHEET NTS 2 OF 2 SCALE D173-06-255 DRAWING NUMBER SOUNDER & LED WIRING DIAGRAMS A3 Live OUT Neutral OUT Earth TITLE DL112H AC COMBINED IF IN DOUBT, ASK DO NOT SCALE ALL DIMENSIONS IN MM E E L L N N C S2 10 REASON - INITIAL - DATE INTRODUCTION RSR - 20/12/2021 Independent Sounder & Beacon Activation (Remove Link Wires) Config.: 2a Two/Three Stage Sounder Configuration Stage 1: Apply Power to Live & Neutral Stage 2: Apply Power to Live & Neutral & connect Stage 2 to Common Stage 3: Apply Power to Live & Neutral & connect Stage 3 to Common SURFACE FINISH WEIGHT (Kg) E E L L N N C S2 4 G F E D C B A Page left Intentionally blank Page left Intentionally blank Page left Intentionally blank
advertisement
Key Features
- Combined sounder & LED beacon
- 24V DC operation
- Adjustable flash patterns
- Multiple tones
- IP66 rated
- -2°C to +55°C operating range
Frequently Answers and Questions
What are the available flash patterns for the DL112HDC024?
The DL112HDC024 offers a variety of flash patterns that can be selected using the DIP switch. These patterns include Steady on, Blinking, Flashing 1Hz, Flashing 1.5Hz, Flashing - Double Strike, Flashing - Triple Strike, Flashing 2Hz, and Flashing - Temporal.
How can I change the alarm tone on the DL112HDC024?
The DL112HDC024 offers a range of alarm tones that can be selected using DIP switches. Refer to the 'Stage 1 Tone Table' in the instruction manual for a list of available tones and their corresponding switch settings.
What is the maximum sound pressure level (SPL) of the DL112HDC024?
The DL112HDC024 has a maximum sound pressure level (SPL) of 119dB(A) at 1 meter.