The JOOBY Avenue C4 Series is a versatile and powerful LED luminaire designed for various applications, including street and road lighting, park illumination, and industrial spaces. Featuring a modular design with up to five light modules and a front section with optional surge protection, this luminaire offers high performance and energy efficiency. It can be mounted on consoles, poles, or suspended using various mount types, allowing for flexible installation. The Avenue C4 Series is equipped with advanced features like adjustable tilt, turn, and elevation angles, ensuring optimal light distribution and achieving desired illumination levels.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
JOOBY ™ AVENUE luminaires series USER MANUAL This user manual contains information about the JOOBY AVENUE luminaires (hereinafter referred to as "luminaires"), and sets the rules of exploitation and storage of the device. 1 GENERAL INFORMATION 1.1 Luminaires are compliant to the requirements of Directive LVD 2014/35/EU, Directive EMC 2014/30/EU, EN 60598-1, EN 60598-2-3, EN 60598-2-1, EN 60598-2-5. 1.2 Denotation of possible luminaires options: Avenue S2x80-S1-5K7H-Ci-SPС-Т1 Housing type: Avenue S2x80-S1-5K7H-Ci-SPС-Т1 Avenue S2x80-S1-5K7H-Ci-SPС-Т1 Avenue S2x80-S1-5K7H-Ci-SPС-Т1 Avenue S2x80-S1-5K7H-Ci-SPС-Т1 Avenue S2x80-S1-5K7H-Ci-SPС-Т1 С – console; S – suspended. Quantity of light modules: from 1 to 5. Power consumption of each light module: 20 – 20 W; 30 – 30 W; 40 – 40 W; 60 – 60 W; 80 – 80 W. Optical system type: S1 – asymmetrical glass lens 145°x65°; S2 – asymmetrical glass lens 170°x120°; S3 – asymmetrical glass lens 160°x80°; S4 – asymmetrical glass lens 150°x70°; S6/T1 – 28 LEDs asymmetrical lens arrays, type I S6/T2 – 28 LEDs asymmetrical lens arrays, type II; S6/T3 – 28 LEDs asymmetrical lens arrays, type III; S6/T5s – 28 LEDs symmetrical lens arrays, type V; S6/Sc – 28 LEDs symmetrical lens arrays, type II/III (long); F1/45 – symmetrical glass lens 45°x45°; F1/60 – symmetrical glass lens 60°x60°; F1/90 – symmetrical glass lens 90°x90°; F1/120 – symmetrical glass lens 120°x120°; F6/30 – 28 LEDs symmetrical lens arrays 30°x30°; F6/65 – 28 LEDs symmetrical lens arrays 65°x65°; F6/90 – 28 LEDs symmetrical lens arrays 90°x90°; F7/18 – 36 LEDs symmetrical lens arrays 18°x18°; F7/22 – 36 LEDs symmetrical lens arrays 22°x22°; F7/30 – 36 LEDs symmetrical lens arrays 30°x30°; F7/45 – 36 LEDs symmetrical lens arrays 45°x45°; F7/1840 – 36 LEDs symmetrical lens arrays 18°x40°; F7/115d – 36 LEDs matt symmetrical lens arrays 115°x115°; F7/125 - 36 LEDs symmetrical lens arrays 125°x125°. Correlated colour temperature: 3К – 3000 К; 4К – 4000 К; 5К – 5000 К; 5.7К – 5700 К; 6.5К – 6500 К. 2 Avenue S2x80-S1-5K7H-Ci-SPС- Т1 Colour rendering index: 7 – 70 -79; 8 – 80 - 89; 9 – ≥90. Efficacy category: Avenue S2x80-S1-5K7H-Ci-SPС-Т1 T – ≥91 lm/W (tiny); I – ≥101 lm/W (initial); S – ≥111 lm/W (small); M – ≥121 lm/W (medium); L – ≥131 lm/W (large); Н – ≥141 lm/W (high); E – ≥151 lm/W (extra); U – ≥161 lm/W (ultra). LED manufacturer:* Avenue S2x80-S1-5K7H-Ci-SPС-Т1 Ci – Citizen Electronics Co., Ltd; Os – Osram AG; Se – Seoul Semiconductor Co., Ltd; Cr – Cree Inc. Surge protection module:* Avenue S2x80-S1-5K7H-Ci-SPС-Т1 SP –10 kА, uncontrollable; SPC – 10 kА, controllable; SP2 – 20 kА, uncontrollable; SP2C – 20 kА, controllable. Mount type:** Avenue S2x80-S1-5K7H-Ci-SPС-Т1 T1 – for hanging rope, 3d; F1 – narrow floodlight type, 2d; F2 – narrow floodlight type, 3d; F3 – wide floodlight type; Fw – wide floodlight type, separate; R – eye nut; Rх2 – eye nut, 2pcs. * Symbols are present in luminaire designations only when corresponding options are included. ** Used only with S-type housing (suspended). Avenue S2x80-S1-5K7H-Ci-SPС-Т1 The manufacturer reserves the right to make changes in design and designation of luminaire options, which do not worsen products technical characteristics. 1.3 Product description, serial number, manufacturing date — see chapter 11. 1.4 Manufacturer: “TELECOMMUNICATION TECHNOLOGIES Ltd” Office address: 65026, Ukraine, Odessa, 1 Mytna Ploscha Phone: +380 48 759-09-09 E-mail: [email protected], www.jooby.com.ua 3 2 ABOUT PRODUCT 2.1 The luminaire is intended for illumination of streets, roads, highways, tunnels, bridges, parks, residential areas, industrial locations, public spaces, administrative buildings, parking lots, etc. The luminaire can be used for general internal illumination of production halls, warehouses, stores, auxiliary rooms, etc. The light source is an irreplaceable light-emitting-diode module. 2.2 The luminaire is intended for exploitation in the AC mains with 230 V rated voltage and 50 Hz frequency. 2.3 Luminaire remains its efficiency with ambient temperature from minus 40 to 50 °С. 2.4 Depending on the embodiment, in accordance with chapter 1.2, the luminaire has the builtin surge protection module and is capable of working at the following conditions: – SP and SPС options – according to EN 61000-4-5 (4 kV/2 kА, 6 kV/3 kА, 10 kV/5 kА) and IEEE C62.41.2 category С Low (6 kV/3 kА); – SP2 and SP2С options – according to EN 61000-4-5 (4 kV/2 kA, 6 kV/3 kА, 10 kV/5 kА) and IEEE C62.41.2 category С High (20 kV/10 kА). 2.5 The luminaire is suitable for mount on surface of materials with normal flammability rank. 2.6 The mounting method, depending on luminaire embodiment and mount type, is encoded according to table 2.1. Table 2.1 Luminaire option Avenue СX-… Avenue SX-…-T1 Avenue SX-…-F1 Avenue SX-…-F2 Avenue SX-…-F3 Avenue SX-…-Fw Avenue SX-…-R Avenue SX-…-Rx2 Mounting method on console (tube) on vertical pole on bearing cable on a wall or ceiling on suspended rope 4 3 TECHNICAL SPECIFICATION 3.1 Basic characteristics: – – – – – – Limit voltage value, V AC frequency, Hz Power factor Colour rendering index (CRI) Ingress protection according to EN 60529 Protection class against electric shock to EN 60598-1 – Lifetime, h – Lumen maintenance – Failure fraction corresponding to the lifetime in – – – – – accordance – min 120, max 280 50 ≥0,95 ≥70 IP66 І – ≥100000 – L70 – F50 3.2 Rated power of the luminaire Р, W is calculated by the formula: Р=Рмn, (1) where Рм – rated power of light module, W; n – quantity of light modules. The consumed power of the luminaire must not exceed 10 % of the rated values. 3.3 Rated luminous flux of luminaire of , lm is calculated by the formula: Ф=Фмn, (2) where Фм – rated luminous flux of the light module, lm; n – quantity of light modules. The actual luminous flux of the luminaire must be not less than 90 % from the rated value. 3.4 Rated power and luminous flux of the light modules are encoded according to table 3.1. Table 3.1 Nominal luminous Group of luminous efficacy of efficacy the module, lm/W T 100 I 110 S 120 M 130 L 140 H 150 E 160 U 170 Rated power of a single module, W 20 30 40 80 Class of energy efficacy 8000 8800 9600 10400 11200 12000 12800 13600 A+ A+ A+ A++ A++ A++ A++ A++ 60 Rated luminous flux of a single module, lm 2000 2200 2400 2600 2800 3000 3200 3400 3000 3300 3600 3900 4200 4500 4800 5100 4000 4400 4800 5200 5600 6000 6400 6800 6000 6600 7200 7800 8400 9000 9600 10200 3.5 The luminaire’s energy efficiency class is determined by the class of the light module in accordance with table 3.1. 3.6 The light intensity distribution diagram and average beam angle of the luminaire depending on the optical system type are encoded according to table 3.2. 5 Table 3.2 Optical system type S1 S2 S3 S4 S6/T1 S6/T2 S6/T3 S6/T5s S6/Sc F1/45 F1/60 F1/90 F1/120 F6/30 F6/65 F6/90 F7/18 F7/22 F7/30 F7/45 F7/1840 F7/115d F7/125 Intensity distribution diagram figure 3.1 figure 3.2 figure 3.3 figure 3.4 figure 3.5 figure 3.6 figure 3.7 figure 3.8 figure 3.9 figure 3.10 figure 3.11 figure 3.12 figure 3.13 figure 3.14 figure 3.15 figure 3.16 figure 3.17 figure 3.18 figure 3.19 figure 3.20 figure 3.21 figure 3.22 figure 3.23 Average beam angle 145°/65° 170°/120° 160°/80° 150°/70° 145°/80° 160°/50° 150°/60° 140° 160°/65° 45° 60° 90° 120° 30° 65° 90° 18° 22° 30° 45° 18°/40° 115° 125° Figure 3.1 Figure 3.2 Figure 3.3 Figure 3.4 Figure 3.5 Figure 3.6 Figure 3.7 Figure 3.8 Figure 3.9 6 Figure 3.10 Figure 3.11 Figure 3.12 Figure 3.13 Figure 3.14 Figure 3.15 Figure 3.16 Figure 3.17 Figure 3.18 Figure 3.19 Figure 3.20 Figure 3.21 Figure 3.22 Figure 3.23 7 3.7 The correlated colour temperature in depending on luminaire options is encoded according to table 3.3. Table 3.3 Luminaire option Avenue …-3КХХ-… Avenue …-4КХХ-… Avenue …-5КХХ-… Avenue …-5.7КХХ-… Avenue …-6.5КХХ-… Correlated colour temperature, K Rated value Tolerance intervals 3000 2850 - 3250 4000 3750 - 4250 5000 4750 - 5350 5700 5350 - 6000 6500 6000 - 7000 3.8 Luminaires dimensions and mass, depending on housing type, mount type and light modules quantity, are encoded according to table 3.4. Table 3.4 Housing type and quantity of light modules Avenue С1 Avenue С2 Avenue С3 Avenue С4 Avenue С5 Avenue S1 Avenue S2 Avenue S3 Avenue S4 Avenue S5 Mount type Dimensions, mm, not more than Single glass lens T1 F1 F2 R T1 F1 F2 Rх2 F3 Fw Rх2 F3 Fw Rх2 F3 Fw Rх2 390х250х130 525х250х130 660х250х130 790х250х130 925х250х130 260х250х220 260х250х215 260х250х290 260х250х175 395х250х220 395х250х215 395х250х290 395х250х175 530x250x215 530x250x215 530x250x175 665x250x215 665x250x215 665x250x175 800х250х215 800х250х215 800х250х175 Mass, kg, not more than Optical system type Plastic lens Single glass array lens 390х250х110 525х250х110 660х250х110 790х250х110 925х250х130 260х250х200 260х250х195 260х250х270 260х250х155 395х250х200 395х250х195 395х250х270 395х250х155 530x250x195 530x250x195 530x250x155 665x250x195 665x250x195 665x250x155 800х250х195 800х250х195 800х250х155 8 5,5 8,4 11,3 14,2 17,1 4,2 4,1 4,4 4 7,1 7 7,3 7,1 10,4 10,2 9,9 13,2 13 12,7 16,1 15,9 15,6 Plastic lens array 5,3 8 10,7 13,4 16,1 4 3,9 4,2 3,8 6,7 6,6 6,9 6,7 9,8 9,6 9,3 12,4 12,2 11,9 15,1 14,9 14,6 Projected area, m2, not more than 0,07 0,103 0,135 0,167 0,2 0,058 0,09 0,123 0,155 0,188 4 DELIVERY SET 4.1 The delivery set of the luminaire is specified in table 4.1. Table 4.1 Item Quantity Luminaire М10х60 screw Т1 mount set F1 mount set F2 mount set F3 mount set Fw mount set R mount set 1 pcs. 2 pcs. 1 pcs. 1 pcs. 1 pcs. 1 pcs. 1 pcs. 1 pcs. 2 pcs. 1 pcs. 1 pcs. User manual Package Commentary Avenue СХ-… Avenue SX-…-T1 Avenue SX-…-F1 Avenue SX-…-F2 Avenue SX-…-F3 Avenue SX-…-Fw Avenue SX-…-R Avenue SX-…-Rx2 5 SECURITY MEASURES 5.1 In terms of security measures the luminaire is completed in accordance with EN 60598-1, EN 60598-2-3, EN 60598-2-1, EN 60598-2-5, requirements. 5.2 Installation and maintenance of the luminaire must be executed by skilled specialist, authorized to work on electrical installations under voltage up to 1000 V. 5.3 Disconnect from power supply before installing and maintaining the luminaire. 5.4 Connecting the luminaire to power supply which properties are different from those indicated in marking of the luminaire is prohibited. 5.5 The luminaire must be grounded to avoid electric shock. 5.6 DO NOT: – assemble, disassemble or service a luminaire with connected power supply; – switch on a disassembled luminaire; – use a mechanically damaged luminaire; – use luminaire with the damaged isolation of wires or places of electric connections; – use luminaire without protective grounding; – lift and hold the luminaire by the cable; – use luminaire for unintended purposes. 9 6 DESCRIPTION 6.1 Common description The luminaire has a module structure. The basic functional unit of the luminaire is the light module, which consists of aluminum housing, LED light source, driver and secondary optical system (lens with accompanying parts). Depending on the housing type, there are two types of modules: “Console” and “Middle”. Depending on the embodiment, luminaires can contain from one to five light modules and one (Avenue СХ-... option) or two (Avenue SХ-... option) front sections. Depending on the embodiment, the front section (figure 6.1) may contain the surge protection module (Avenue -SP-, -SPC-, -SP2-, -SPC2- options) and additional power regulation devices. To connect luminaire to the power supply an external flexible three-core cable is used. For expansion of luminaire functions, the front cover may be replaced with ASC (Avenue Smart Cover) Control Devices in variety of options. Notes 1 To connect additional power regulating device, or ASC Control Device, the system connector is used (figure 6.1). 2 ASC Control Device may be installed by the manufacturer, or purchased separately and installed by user to upgrade the already bought luminaire. 3 Description and exploitation details of ASC Control Device are given in the appropriate user manual. Figure 6.1 – Front section without removed cover 6.2 Console luminaires (Avenue СХ option) The console luminaire consist of the Console Light Module and front section (Avenue С1 option) or Console Light Module, front section and from one to four Middle Light Modules (Avenue С2 − Avenue С5 options). The console luminaire is equipped with a mounting bracket for set on tubes with diameter from 40 to 65mm. The construction of mounting bracket allows to set the luminaire on L-type console (figure 6.2) or vertical pole (figure 6.3) and provides tilt adjustment from minus 5° to +30° with a 2,5° step. 10 Figure 6.2 – Luminaire set on a L-type console Figure 6.3 - Luminaire set on a vertical pole 6.3 Suspended luminaires (Avenue SХ option) The suspended luminaire consist of Middle Light Modules (from 1 to 5 depending on the model) and two front sections. Suspended luminaires can be equipped with different mount types. List of mount types, their description and compatibleness with luminaire options is given in table 6.1. Table 6.1 Code Title Description T1 Suspended, bearing cable, 3d F1 Narrow floodlight, 2d Narrow floodlight, 3d For hanging on bearing cable of diameter from 6 to 12,5 mm. Adjustability: turn angle 0-360°; slope angle ±20°. For mount on hard surface (wall, ceiling, and metal construction). Adjustability: turn angle 0-360°; slope angle ±20°. For mount on hard surface (wall, ceiling, and metal construction). Adjustability: turn angle 0-360°; longitudinal slope angle ±20°; transversal slope angle ±90°. F2 11 Compatible luminaires Avenue S1-…-Т1 Avenue S2-…-Т1 Figure 6.4 Avenue S1-…-F1 Avenue S2-…-F1 6.5 Avenue S1-…-F2 Avenue S2-…-F2 6.6 Continuation of table 6.1 Code F3 Fw R Rх2 Title Description Wide floodlight, lyre Wide floodlight, separated Compatible luminaires Avenue S3-…-F3 Avenue S4-…-F3 Avenue S5-…-F3 Avenue S3-…-Fw Avenue S4-…-Fw Avenue S5-…-Fw For mount on hard surface (wall, ceiling, and metal construction). Adjustability: transversal slope angle ±90°. For mount on hard surface (wall, ceiling, and metal construction). Adjustability: slope angle in transversal plane ±90°; distances between mounting brackets. Suspended, For mount on ceiling by suspended steel Avenue S1-…-R eye nut rope with diameter of 4 mm and more. One attachment point. Suspended, For mount on ceiling by suspended steel Avenue S2-…-Rx2 eye nut, 2 pcs. rope with diameter of 4 mm and more. Avenue S3-…-Rx2 Two attachment points. Avenue S4-…-Rx2 Avenue S5-…-Rx2 12 Figure 6.7 6.8 6.9 6.9 Figure 6.4 – Т1 mount Figure 6.5 – F1 mount 13 Figure 6.6 – F2 mount Figure 6.7 – F3 mount 14 Figure 6.8 – Fw mount Figure 6.9 – R (Rx2) mount 15 7 PRE-LAUNCH PROCEDURE 7.1 Unpack the luminaire and check its integrity and assembly correctness. 7.2 Power supply connection Connection to the power grid must be executed in accordance to national installation rules. An external three-core cable is used to connect the luminaire to the power supply. For correct connection be aware of the wires colour denotation: – brown for "phase" (L); – blue for "zero" (N); – yellow-green for grounding. It is recommended to use a terminal block, which conforms to EN 60998-2-1 or EN 60998-2-2 and fulfills such requirements: – rated voltage - 300 W; – rated current - 4 A; – rated connecting capacity – 2,5 mm2. Notes 1 To maintain declared ingress protection level use terminal blocks with appropriate protection level. 2 Execute any necessary preparation of the ends of conductors in a way meant by terminal block manufacturer. 7.3 Console luminaires (Avenue СХ option) 7.3.1 The luminaire should be installed following such requirements: – the luminaire’s normal working position on L-type console (or on vertical support bracket) is at angle from 0° to 30° to horizon; – the recommended setting height is from 3 to 30 meters (dependently on the luminaire option and specific of its exploitation); – the tube wall thickness must be not less than 1,5 mm; – tube diameter should be from 40 to 65 mm. To fasten the luminaire on tube with diameter from 40 to 54 mm use adjusting screw-bolts from the delivery set; – the depth of the pole inset into the console holder must be at least 90 mm; – tightening torque for fastening bolts must be not less than 17 Nm. Warning! Minimum distance from lighted objects not less than 1 m. 7.3.2 To install the luminaire on vertical pole, change the position of the holder, as shown in figure 7.1. Figure 7.1 – Holder adjustment for vertical set 16 7.3.3 Luminaire installation order: – connect the power wire. The luminaire cable must be passed inside of the tube; – release fastening bolts and set the luminaire on L-type console or vertical pillar. Ensure that the cable was not damaged by squeezing between surfaces and cuts of tubes; – fix the luminaire by tightening fastening bolts. Tighten check-nuts; – loose adjusting screws, adjust the luminaire tilt on vertical axis, then fix it at necessary angle by tightening adjusting screws; – switch on the power and check if the luminaire is working properly. 7.4 Suspended luminaires (Avenue SХ option) 7.4.1 The luminaire should be installed according to the following requirements:: – the normal working position of the luminaire depends on its model and specific of its exploitation; – for F1, F2, F3 and Fw mount type, if the luminaire is exposed to precipitation, it is recommended to orientate it vertically (along the longitudinal axis); – for T1 mount type the diameter of bearing cable must be from 6 to 12,5 mm; – for R and Rx2 mount type use a steel rope with diameter no less than 4 mm; – to hang the luminaire with F1, F2, F3 and Fw mount use screws or screw-bolts with diameter from 5 to 6,5 mm. Notes 1 Screws, screw-bolts and dowels for attachment of luminaire upon mounting surface are not included in the delivery set and should be purchased separately. 2 Type and size of screws, screw-bolts and dowels should be chosen in dependence on type and material of mounting surface. Warning! Minimum distance from lighted objects not less than 1 m. 7.4.2 The luminaire installation order: – set the Т1, F1, F2 mount kit on the luminaire as shown in figures 7.2-7.4. Note: F3, Fw, R and Rx2 mount are installed by the manufacturing enterprise; – fasten the luminaire on: steel rope (Т1 mount); mounting surface (F1, F2, F3 and Fw mount); suspended steel ropes (R and Rx2 mount); – connect power wires; –adjusting position of the luminaire: For Т1 and F1 mount (figures 7.2 and 7.3). Loosen М8 nuts and adjust the turn and tilt angle. Tighten М8 nuts to fix the luminaire; For F2 mount (figure 7.4). Loosen М8 nuts and adjust the turn and elevation angles. To fix the luminaire, tighten М8 nuts. Loosen М6 nuts on the М6х20 screws (see figure 7.4) and adjust the tilt angle in transversal plane. To fix the luminaire, tighten М6 nuts. To change the tilt adjustment range, move the М6х20 screws with the М6 nuts into corresponding hole on U bracket (see figure 6.6); For F3 and Fw mount (figures 7.5 and 7.6). Loosen М6 nuts on the М6х20 screws and adjust the tilt angle. To fix the luminaire, tighten М6 nuts. To change the tilt adjustment range, move the М6х20 screws with М6 nuts into corresponding hole on turning bracket (see figure 6.8). Note: Fw mount allows to change the distance between mounting brackets. For this purpose, loosen М4 screws and move turning brackets (see figure 7.6) on necessary distance. To fixate brackets tighten М4 screws; – switch on the power and check that the luminaire is working properly. 17 Figure 7.2 – T1 mount installation Figure 7.3 – F1 mount installation 18 Figure 7.4 – F2 mount installation Figure 7.5 – F3 mount installation 19 Figure 7.6 – Fw mount installation Figure 7.7 – R (Rx2) mount installation 20 8 MAINTENANCE 8.1 Luminaires require periodical (at least annual) preventive examination of functionality and fastening security. Discovered defects must be fixed. 8.2 Luminaires require cleaning at least twice a year, or when contaminated, with a water jet to remove dirt from between the heatsink ribs and dust from the optical element. Do not use aggressive chemicals and hard brushes that can damage the housing paint or the lens surface. Caution! Do not clean the luminaire with high-pressure cleaners. Warning! Clean the luminaire only when it is switched off. 8.3 The luminaire should be repaired by the manufacturer authorized service center only. 8.4 If the luminaires external flexible power cable is damaged it should be replaced by manufacturer employee or agent or a similar qualified person. 9 UTILIZATION 9.1 The luminaire does not contain toxic materials, as well as components and parts that require special utilization. Utilization of the luminaire is carried out in a usual way. 10 TRANSPORTATION AND STORAGE 10.1 Transportation of the luminaire in the manufacturer's packaging may be carried out by rail, road, water (except sea) and aviation (in hermetic aircraft compartments) transport, with mandatory observance of rules and requirements applicable to these types of transport. Transportation by sea transport is allowed only in special packaging. 10.2 Transportation of packed luminaires can be carried out at ambient temperature from minus 50 to 50 °C and relative humidity up to 100% at 25 °C temperature. 10.3 Placement and fixation of containers with packed luminaires in vehicles should ensure a stable position and immobilization of the container during transportation. Containers with packed luminaires must be protected from precipitation through the transportation period. 10.4 The luminaire should be stored in the manufacturer's packaging in closed, dry rooms with ambient temperature from minus 40 to 50 °C and a relative humidity not exceeding 95% at 25 °C temperature. 10.5 The storage room should be absent of aggressive impurities (acid or alkaline steam) that can cause corrosion in stored luminaires. 10.6 The height of packaged luminaires stacking must not exceed 5 layers. 10.7 The storage period is not limited. 21 11 ACCEPTATION CERTIFICATE Luminaire manufactured and accepted with obligatory observance of state standards, existing technical documentary, and claimed suitable for usage Technological Control Department Supervisor L.S. signature Surname and initials Date 12 MANUFACTURER WARRANTY 12.1 Manufacturer guarantees the quality of the product during specified warranty period for component parts, provided that the consumer fulfills all the requirements for storage, transportation and operation of the product during specified period of time. 12.2 Warranty period of the product is 7 (seven) years from the moment of putting the product into operation, but not more than 7 (seven) years and 6 (six) months from the moment of its delivery to the consumer. Warranty period includes the in-stock and transportation period, but not more then 6 (six) month. If the product remains in-stock longer than the specified period, the warranty period is decreased for a relevant term. 12.3 The manufacturer is obliged to eliminate the identified damage or replace the defective components during the specified warranty period. 12.4 Warranty doesn’t cover luminaire damages caused by: – pulse overvoltage (lightning strike), if the luminaire was not equipped with a surge protection module, according to use terms, or if the surge protection module was not replaced in a timely manner (for luminaires with controlled surge protection module); – voltage with characteristics different to those set in technical specification. 12.5 Luminaires, provided without a completed acceptation certificate and this warranty card, would not be accepted for reclamation. 12.6 Reclamation acts and complaint letters should be sent to the address of manufacturerfacility. Date of sale:_______________ L.S. Supplier ________________ signature 22
advertisement
Key Features
- Modular design
- Up to 5 light modules
- Surge protection option
- Adjustable mounting
- High energy efficiency
- IP66 rating
- Long lifespan