The barbas Cuatro-3 90 * is a wood-burning insert/built-in appliance designed for cozy evenings. It features a robust construction, a flue gas flap for efficient operation, and a combustion air supply slider for precise temperature control. This appliance can be installed as an insert in an existing fireplace or as a built-in appliance in a new or existing chimney breast. It offers various installation options with or without an air-box/fan box, allowing for direct external combustion air supply. Choose from different convection configurations for optimized heat distribution.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Barbas Cuatro-3 90 * Installation Manual | Manualzz
INSTALLATION INSTRUCTIONS &
MANUAL FOR ANNUAL MAINTENANCE
CUATRO-3 90
Wood-burning insert/built-in appliance
Barbas wishes you many cosy evenings with your new fire
This document is an essential part of your fire.
Read it carefully before installation and maintenance
of the gas fire and keep it in a safe place!
Version number: 04 - 332965
Serial number:
Date: 22-11-2017
Production date:
CUATRO-3 90
Installation instructions
3
CUATRO-3 90
4
Installation instructions
CUATRO-3 90
TABLE OF CONTENTS
Page
1
Introduction
1.1 General ................................................................................................
1.2 Safety and installation instructions ......................................................
7
8
Placing
2.1 Included ...............................................................................................
2.2 Preparation for positioning ...................................................................
2.3 Accessories .........................................................................................
10
10
27
Installation
3.1 Instructions ...........................................................................................
3.2 Flue gas channel ..................................................................................
3.3 Fitting ...................................................................................................
3.4 Air box / Fan box ..................................................................................
3.5 Preparation / Function check ...............................................................
29
29
30
44
50
4
Operation ....................................................................................................
51
5
Annual maintenance ...................................................................................
53
6
Replacement parts ......................................................................................
55
7
Dimensions .................................................................................................
59
8
Technical data .............................................................................................
63
9
Warranty terms ...........................................................................................
65
2
3
Installation instructions
5
CUATRO-3 90
6
Installation instructions
CUATRO-3 90
1
INTRODUCTION
1.1 GENERAL
The appliance must be positioned and connected by a Barbas dealer/specialist in
accordance with these Installation instructions, nationally and locally applicable
regulations.
This manual contains directions for both positioning and for connecting the appliance.
It also contains indications for the annual maintenance, technical data for the appliance,
parts information and directions in the event of problems.
Study the Installation instructions carefully before using the appliance. We recommend
you keep this manual in a safe place for reference purposes.
Read the “Instructions for use & maintenance manual” before operating the appliance.
“The Clean Air Act 1993 and Smoke Control Areas”
Under the Clean Air Act local authorities may declare the whole or part of the district of
the authority to be a smoke control area.
It is an offence to emit smoke from a chimney of a building, from a furnace or from any
fixed boiler, if located in a designated smoke control area.
It is also an offence to acquire an “unauthorised fuel” for use within a smoke control
area unless it is used in an “exempt” appliance (“exempted” from the controls which
generally apply in the smoke control area).
The Secretary of State for Environment, Food and Rural Affairs has powers under the
Act to authorise smokeless fuels or exempt appliances for use in smoke control areas in
England.
In Scotland and Wales this power rests with Ministers in the devolved administrations
for those countries. Separate legislation, the Clean Air (Northern Ireland) Order 1981,
applies in Northern Ireland.
Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas
have been “authorised” in Regulations and that appliances used to burn solid fuel in
those areas (other than “authorised” fuels) have been exempted by an Order made and
signed by the Secretary of State or Minister in the devolved administrations.
Further information on the requirements of the Clean Air Act can be found here:
http://smokecontrol.defra.gov.uk/
Your local authority is responsible for implementing the Clean Air Act 1993 including
designation and supervision of smoke control areas and you can contact them for
details of Clean Air Act requirements.
Installation instructions
7
CUATRO-3 90
1.2 SAFETY AND INSTALLATION INSTRUCTIONS
Safety
• Do not place flammable objects within 150 cm of the appliance. Pay special attention
to furnishings and ornaments around the appliance.
• When you use your appliance, the exterior will become hot. Always wear the glove
or use the accessories supplied when filling etc.
Protect yourself and others (especially children!) from burns. Do not leave children
unattended when the appliance is burning.
• Watch your clothing. Synthetic clothing in particular can easily catch fire and burn
intensely.
• Do not approach the appliance with flammable materials or liquids. Any work with
solvents, adhesives etc. in the space heated by the appliance can be very
dangerous.
• It is not allowed to connect the appliance to a flue which is already connected to
another appliance.
• Cheak the chimney. Cracks in the chimney may not only lead to damp, staining
of walls and leaking of smoke, they can also impair the carrying off of smoke.
• Prevent your chimney being soiled from above (birds’ nests etc.) by fitting a suitable
cap to the chimney pot.
• Avoid chimney fires! Have your chimney swept at least once per year - more often
if you use your fire a lot. Prevent excessive deposits of soot inside the chimney by
not burning freshly-cut wood. Instead, burn clean, dry chopped wood.
• Follow the instructions issued by your local fire brigade.
The appliance can be taken in operation if national and local regulations are satisfied.
The required constructive adaptations should be satisfied as well.
• It is essential that the appliance, the flue and combustion air supply are cleaned and
inspected annually by a Barbas dealer/specialist.
The safe operation of the appliance will thus remain guaranteed.
• The appliance is suitable and approved for periodical use.
8
Installation instructions
CUATRO-3 90
Installation instructions
• The appliance may only be set up if the appliance and location meets the
- national and local installation regulations;
- local fire brigade regulations and required architectural provisions.
• Ensure that the room in which the appliance is situated has adequate ventilation.
• Wood and wood briquettes may be stoked in the appliance.
Do not use any coal and liquid fuels or fuel gel in the appliance. The appliance is
not intended for use of this fuels and can be dangerous and lead to damage to your
health and may seriously damage the appliance.
• Never use the appliance to burn rubbish.
• Please read all instructions / stickers on and around the appliance.
• Read the “Directions for use” before using the appliance for the first time. When you
first fire up your appliance, there are a number of extra points you should take into
account.
• In transit, some parts of the appliance may have moved from their original place.
Check that the door opens and closes, the brake plate is fitted correctly to the
brackets at the top of the appliance, the heat-resistant panels are fixed to the walls
and the panels on the bottom have not moved. Check if there are no foreign objects
in the appliance.
• Avoid over-loading (white burning glow), caused, for example, by lengthy burning
with primary air (combustion air supply slider all the way to “ + ”) or by burning too
much wood in one go. The appliance can then become over-heated.
This may damage the metal flue gas flap.
• Ask for the local building regulations, before commensing the installation of the
appliance.
Installation instructions
9
CUATRO-3 90
2
LOCATION
2.1
INCLUDED
Set documentation
Installation instructions
Directions for use
Attributes
Glove (Heat resistant up to max. 95°C)
Operating hook / Poker
N.B. If any part is missing, please contact your dealer.
2.2
PREPARATION FOR POSITIONING
Check all functions of the appliance before fitting.
• Check the opening and closing operation of the door.
Turn the handle all the way down:
Door is locked.
10
Installation instructions
CUATRO-3 90
Handle forwards:
The door releases from its lock and can be opened forwards.
For this, use the operating hook supplied.
• Check the operation and setting of the flue gas flap.
Locking for operating pin
flue gas flap (inside door)
Operating pin flue gas flap
Flue gas flap
Combustion air-supply slider
Locking for operating pin of flue gas flap (inside of door).
close
Locking closed (turned to the left)
Installation instructions
open
Locking open (turned to the right)
11
CUATRO-3 90
Locking slider all the way to the left (closed):
Flue gas flap operation works normally:
Door open
Pin comes forwards
Flue gas flap open
Door closed
Pin is pressed in by the door
Flue gas flap closed
Locking slider all the way to the right (open):
Flue gas flap always remains open !!
•
Flue gas flap in “open” position.
•
Operating pin flue gas flap.
• Check whether the retardant plate (brake plate) is located correctly in the supports.
• Check the operation of the slider for the regulation of the combustion air intake
(middle below the window).
12
Installation instructions
CUATRO-3 90
• Check whether the ashtray is completely empty.
• Report any defects immediately to your dealer.
• Remove enclosed documents and components from the appliance.
•
Important:
Decide how to install the appliance.
There are many possibilities !
See also chapter 3.3 Fitting.
Dependent on the type of fireplace where
the appliance is located /installed.
Installation instructions
13
CUATRO-3 90
Connection Possibilities:
I
Mounting as inset in an existing fireplace.
(Combustion air supply opening at the bottom of the appliance is closed, by
placing the appliance on a flat floor.)
A Insert, no open space in top of the fireplace
B Insert, with convection set, with open space in top of the fireplace.
C Insert, with open space in top of fireplace.
Convection air through the chimney breast.
14
Installation instructions
CUATRO-3 90
II
Installing as a build-in appliance in an existing or new fireplace.
The chimney breast is totally empty.
A Build-in appliance.
B Build-in appliance, with convection set.
C Build-in appliance, convection air through the chimney breast.
Installation instructions
15
CUATRO-3 90
III
Installing as build-in appliance with an air-box / fan box for direct external supply of
combustion air.
A Build-in appliance with air-box / fan box.
Convection air supply through the front of the appliance.
No empty space in the chimney breast above the appliance.
Ventilate the chimney
breast, when it is totally
empty, by placing vents in
the top and bottom of the
chimney breast.
B Build-in appliance with air-box / fan box.
Convection air supply through inlets at front of the appliance.
With convection set.
The chimney breast is totally empty.
16
Installation instructions
CUATRO-3 90
C Build-in appliance with air-box / fan box.
Convection air supply through inlets at front of the appliance.
Convection air through the chimney breast.
The chimney breast is totally empty.
D Build-in appliance with air-box / fan box.
Convection air supply through a grate in the bottom side of the fireplace.
No empty chimney breast above the appliance.
Ventilate the chimney breast,
when it is totally empty, by
placing grates in the top and
bottom of the chimney breast.
Installation instructions
17
CUATRO-3 90
E Build-in appliance with air-box / fan box.
Convection air supply through a grate in the bottom side of the fireplace.
With convection set.
The chimney breast is totally empty.
F Build-in appliance with air-box / fan box.
Convection air supply through a vent in the bottom side of the fireplace.
Convection air through the chimney breast.
The chimney breast is totally empty.
18
Installation instructions
CUATRO-3 90
IV
Installing as build-in appliance, with air-box / fan box.
• Directly external combustion air supply
• Convection fan with built-in dimmer switch
• Convection air supply through a grate/opening from the living room
A Build-in appliance with air-box / fan box.
No empty space above the appliance.
Ventilate the chimney
breast, when it is totally
empty, by placing vents in
the top and bottom of the
chimney breast.
B Build-in appliance with air-box / fan box.
With convection set.
The chimney breast is totally empty.
Installation instructions
19
CUATRO-3 90
C Build-in appliance with air-box / fan box.
Convection air supply through the chimney breast
The chimney breast is totally empty.
= Closed
(“break away” discs)
= Open
(“break away” discs)
= Grate
Ventilation openings chimney breast
= Grate
Combustion air supply via wall outlet
Convection set:
20
Installation instructions
CUATRO-3 90
• Only when the appliance is installed as an insert appliance (installation option I A,
I B and I C) should the openings for combustion and convection air at the front of the
appliance be opened.
The “closed” discs should be exchanged for “open” discs (delivered with the appliance).
• Remove the “closed” discs located on the far left and right openings with an allen key.
• Remove the inner “closed” discs (left and right) with an allen key.
Installation instructions
21
CUATRO-3 90
• “Open” discs.
• Mount the “open” discs on the far left and right openings with an allen key.
• Mount the inner “open” discs (left and right) with an allen key.
22
Installation instructions
CUATRO-3 90
• Appliance, equipped with “open” discs.
The openings on the far left and right are the convection air inlets.
The inner left and right openings are the combustion air inlets.
• Permanent inlet opening at the bottom of the appliance.
Combustion air supply
opening under the
appliance
Convection air intake opening
under the appliance
Installation instructions
23
CUATRO-3 90
•
Ventilation casing / chimney.
Ensure that the casing/chimney has sufficient ventilation openings (See
Chapter 3 and 4).
Important:
Only open those convection air
outlets, as defined by the chosen
installation option.
• Opening of 2 convection air outlets.
24
Installation instructions
CUATRO-3 90
• Opening of 4 convection air outlets.
Installation instructions
25
CUATRO-3 90
Have the suitability of the area in which the fire is to be fitted (and the chimney) approved
by a specialist. The space into which the appliance is to be fitted must in no way be
damaged. The appliance must have its own chimney, constructed in compliance with
current legislation.
26
Installation instructions
CUATRO-3 90
2.3
ACCESSORIES
The following accessories can be supplied by your dealer:
Part. no
Accessorie
............
A
Air-box / Fan box:
312829
B
Convection set General: (for convection air extraction)
Advice:
• Appliance without air-box / fan box:
The use of a convection set is strongly recommended.
• Appliance with air-box / fan box:
The use of a convection set is possible, but not mandatory.
302188
• 1x Flexible aluminium pipe
Ø125 mm, L= 3 m (max.)
• 2x Fitting box 135x135 mm
• 2x Convection exit grid,
white, 145 x 145 mm
• 2x Collar adaptor Ø125 mm
• 4x Hose clamp Ø125 mm
310178
309872
309730
304040
............
C
3-Sided 35 mm frame
............
D
4-Sided 35 mm frame
309872
310178
E
Grate ventilation chimney
Fitting box for grate ventilation chimney
Installation instructions
27
CUATRO-3 90
Part no
330361
28
Accessorie
F
Set of high adjustable feet
Installation instructions
CUATRO-3 90
3
INSTALLATION
3.1 INSTRUCTIONS
When fitting one of these appliances local and/or national regulations relating to fire
safety must be followed. In case of doubt, consult the fire safety department of the local
fire brigade, particularly if the fire is to be fitted in a home with walls and/or floors
containing flammable material.
The connection of several appliances to a single flue/chimney is not allowed.
3.2 CHIMNEY
If no chimney is immediately available, have one fitted by a recognised specialist only.
The chimney must be compliant with local regulations and is particularly important because it has a significant bearing on the function of the appliance.
Basic rules:
• A chimney for an open appliance is not, by definition, suitable for a closable model
(i.e. an appliance with doors). As a closed appliance draws in much less (cold) air,
the smoke is hotter. Please have your chimney inspected to see whether it is suitable
for a closable appliance.
• The chimney opening must be at least 5 metres above the top of the door opening of
your appliance.
• The chimney must protrude at least 40 cm above the apex of a sloping roof and at
least 1 metre above a flat roof. In short, the chimney must always end in an area with
a negative air pressure. Contact your local chimney sweep
for the exact dimensions of the chimney opening.
• The internal diameter must not be less than that of the appliance at any point (even
at the end of the pipe).
• Avoid bends at all costs. The maximum deviation from the perpendicular is 45°.
• Both the dimensions and the construction must meet stringent construction
standards. Your recognised specialist will be pleased to assist.
• Contact your fire insurer to make sure that your policy is in order.
Installation instructions
29
CUATRO-3 90
3.3 FITTING
An appliance can be fitted in the newly-built or existing chimney breast of an open fire.
When fitting, both fire safety and operational safety must be safeguarded. The fitter is
responsible for this.
General guidelines:
• If there is a wooden beam above the fitting location, heat must not radiate directly
onto it. An insulation plate must be hung below the beam, leaving an air gap between
it and the beam of at least 1 cm.
• Always use (white) unbound ceramic insulation wool. Bound material (yellow), such
as glass and rock wool, spreads an irritating smell on heating, causes excess smoke
and is unsuitable for high temperatures.
Insulation requirements:
• temperature resistance ≥ 700°C.
• density ≥ 80 kg/m3
• Have any electrical connection for the Perma Air ® convection fan box carried out by
a professional electrician.
Note ! : The fan set should be connected to an earthed wall socket.
This socket must remain accessible at all times.
• Before fitting, remove the door to protect the glass.
3.3.1 Positioning of the appliance
The appliance must be positioned on a concrete surface. If such a surface is not immediately available, a sufficiently solid pedestal of noninflammable material should be built
from the creeping space.
The appliance can be placed in position using the carrying brackets (dealer-accessorie)
supplied.
Ventilate the empty space in the chimney, by placing ventilation openings at the top and
bottom of the chimney breast.
The total ventilation openings should be at least 450 cm2 at the bottom of the chimney
breast and also at least 450 cm2 at the top of the chimney breast.
(Total ventilation openings: 900 cm2.)
30
Installation instructions
CUATRO-3 90
The ventilation openings at
the top should be at least
50 cm below the ceiling
Ventilation openings
Figure 1: Use of ventilation of chimney
Installation instructions
31
CUATRO-3 90
Examples installation possibilities.
I
A Appliance as an insert-appliance in an existing chimney.
I
B Appliance as an insert-appliance in an existing chimney.
Fitted with a convection set and ventilation of the chimney.
Legend page 36 and 37
32
Installation instructions
CUATRO-3 90
I
C Appliance as an insert-appliance in an existing chimney.
Convection air through the chimney breast.
Fitted with ventilation of the chimney.
II A Appliance as a build-in appliance in an existing or a new chimney.
Fitted with ventilation of the chimney.
Legend page 36 and 37
Installation instructions
33
CUATRO-3 90
II B Appliance as a build-in appliance in an existing or a new chimney.
Fitted with a convection set and ventilation of the chimney.
II C Appliance as a build-in appliance in an existing or a new chimney.
Convection air through the chimney breast.
Fitted with ventilation of the chimney.
Legend page 36 and 37
34
Installation instructions
CUATRO-3 90
III
E Appliance as a build-in appliance with an air-box / fan box.
For a direct combustion air supply from outside.
Fitted with an convection set and ventilation of the chimney.
IV
B Appliance as a build-in appliance with an air-box / fan box.
For a direct combustion air supply from outside and fitted with a
convection fan with a build-in fanspeed controller.
Appliance is fitted with a convection set and ventilation of the chimney.
Legend page 36 and 37
Installation instructions
35
CUATRO-3 90
Appliance:
1
Inlet opening combustion air (front of appliance, bottom, 2x
Important:
37 x 150 mm).
dismount 2x “closed” discs (left and right of the combustion air-supply slider)
and mount 2x “open” discs with opening; 37x150 mm. (Only valid when
1 is stated on the drawing.)
2
Inlet opening combustion air (bottom of appliance, Ø125 mm) / (air-box,
Ø125 mm) / (fan box, Ø125 mm).
3
Inlet opening convection air (front of appliance, bottom, 2x
Important:
37 x 97 mm.)
dismount 2x “closed” discs (left and right of the combustion air-supply slider)
and mount 2x “open” discs with opening; 37 x 97 mm. (Only valid when
3 is stated on the drawing.)
4
Inlet opening convection air (bottom of appliance,
(fan box, Ø125 mm)
5
Flue connection (topside of appliance, Ø200 mm)
6
Outlet opening convection air (front of appliance, above)
7
Outlet opening convection air (top of appliance) / (Connection convection set)
(2x or 4x Ø125 mm)
Important:
8
20 x 480 mm) /
Remove “break-away” discs (2x or 4x Ø125 mm)! (Only valid when 7 is stated on
the drawing.)
Insulation material, noninflammable ‼! (for example ceramic fibre) (sides and top
of appliance)
Chimney / Chimney breast:
9
Inlet opening combustion air/convection air/chimney-ventilation air (grate,
bottom of chimney)
10
Outlet opening convection air/chimney-ventilation air (grate, top of chimney)
11
Outlet opening convection air via convection set (grate, top of chimney)
Exterior wall:
12
36
Inlet opening combustion air (grate, exterior wall).
Installation instructions
CUATRO-3 90
Options:
13
Air-box / Fan box:
15
High adjustable feet (set of 4 pieces)
16
Convection set
17
Fanspeed controller (build-in) for RPM control of the convection fan.
Installation instructions
Box with several connection possibilitys for a directly
combustion air supply from outside and/or a build-in
convection fan including a fanspeed controller for
RPM control.
37
CUATRO-3 90
3.3.2 Aeration / ventilation
The appliance generates: - heating air
- combustion air
Heating air (convection air) is devoted to the convection of heat from the appliance to
the room. The source of heat is in the room and stays there.
Combustion air is needed to keep the combustion going by drawing in air from the
room, of directly from outside, due to the natural draught of the chimney.
• Combustion air from the living-room:
The air inlet openings are located behind the operating flap. When using the
appliance, please ensure there is a sufficient supply of fresh air: use a grate with a
minimum net opening in the outer wall of 150 cm2.
When necessary, the combustion air inlet Ø125 mm at the underside of the appliance
may be used. Through the hollow space, underneath the appliance, and a grate in
the chimney breast, combustion air can be supplied from the living room.
Make sure that the ventilation supply is open; this is particularly important with
today’s airtight dwellings
If the dwelling has mechanical ventilation that creates under pressure in the room
where the appliance is located, it is necessary to fit a flue gas fan.
The type of flue gas fan is dependent on the capacity of the mechanical ventilation
system. Always consult your fitter about this.
In dwellings with an operating extractor hood, this should be turned to the lowest
setting or turned off altogether. If the extractor hood remains in use, additional
ventilation must be provided in compensation. This will not only avoid poor
combustion, but will also prevent flue gases being sucked from the appliance into
the room.
Should creating an extra ventilation opening prove insufficient, it is then necessary
to fit a flue gas fan.
38
Installation instructions
CUATRO-3 90
• Combustion air directly from outside:
The appliance now has a completely closed combustion system, which allows it to
operate independently of the surrounding air in the room where the appliance is
located.
- Appliance with substructure air-box:
Use one of the three combustion air supply connections Ø125 mm (external)
of the air-box / fan box.
Fit a rigid or flexible pipe measuring Ø125 mm between this air supply connection
and the “outside air supply opening in the wall/floor”.
We recommend that this pipe is fitted with a sealing valve in order to prevent
condensation in the appliance when it is not in use.
- Appliance with substructure fan box (convection fan):
Use the Ø125 mm (external) combustion air supply connection at the left of right
front side or the bottom side of the air-box / fan box.
Fit a rigid or flexible pipe measuring Ø125 mm between this air supply connection
and the “outside air supply opening in the wall/floor”.
We recommend that this pipe is fitted with a sealing valve in order to prevent
condensation in the appliance when it is not in use.
3.3.3 Fitting in an existing chimney
• Remove the existing fire basket or stoking stones and remove the shut-off flap. The
chimney must be intact and must not be damaged during fitting.
The chimney breast opening must be big enough for a gap of 1 - 3 cm to be left all
round the appliance. Clad the chimney breast opening from the inside with a ceramic
wool fireblanket or similar (see section 3.3).
• Extend the existing chimney so that it ends at the appliance’s smoke outlet. To do
this, use a flexible, double-walled stainless steel chimney, for example.
• Slide the appliance into the chimney breast opening. Seal the smoke outlet where it
joins the chimney so that no soot can accumulate above the appliance under any
circumstances. See 3.3.4.
• Level off the appliance so that the cover does not catch on the base.
• Fill any gaps around the appliance with a ceramic insulation wool fireblanket and
position the frame (where supplied)
Installation instructions
39
CUATRO-3 90
3.3.4 Fitting in a newly-built chimney
•
If required, a convection set can be added when installing the appliance.
* Appliance without air-box/fan box: The use of a convectionset is
strongly recommended.
* Appliance with air-box/fan box:
The use of a convectionset is possible,
(with build-in fan)
but not mandatory.
•
In the case of utilisation of a convection set:
Carefully break out the “break-away openings” at the topside (2x) or (4x) of the
appliance.
•
Use convection set:
The function of the convection set (option) is to improve the convection through the
appliance, resulting in efficiency improvement and preventing high temperatures in
the chimney.
The set consists of: • 3 m aluflex
• 2 exit grids (white)
• 2 collar adaptors Ø125 mm
• 4 hose clamps
• Assembly convection set:
° Secure the 2 collar adaptors to the appliance.
° Now connect the flexible hoses to the 2 collar adaptors (Ø125 mm) on the top of
the fire and to the metal fitting box on the air exit grids that are being used (do not
forget to fit hose clamps).
Ensure
that the flexible hose connections are gastight.
°
° The air exit grids cannot be fitted until a few days later, once the masonry has
been pointed and allowed to dry. If one or more channels are connected leading
to other rooms, these rooms must be fitted with closable grids. These are available
from your dealer, as well as the flexible hoses and clamps required.
Within
a range of 30 cm either side and 50 cm above the escape opening (exit
°
grids), there must be no flammable materials (e.g. wooden ceiling, fitted furniture).
•
Clad the appliance on the top, sides and rear up to the front edge with an approx.
10 cm thick ceramic isolation wool fireblanket. Leave a few centimetres clearance
between the front of the chimney and the appliance.
•
Level off the appliance.
•
Make a good seal between the smoke outlet from the appliance to the chimney.
See also 3.3.5.
Ensure that the entire flue is gas-tight.
• Ventilate the chimney, by placing ventilation openings at the top and bottom of the
chimney.
40
Installation instructions
CUATRO-3 90
Figure 2: Use of convection set and ventilation of the chimney
• Close up the front.
Available BARBAS grids (option) for ventilating the chimney:
COLOUR
DIMENSION (cm)
CLEAR OPENING (cm2)
Brass or white
(incl. fitting)
13.5 x 13.5
75
Brass or white
(incl. fitting)
27.0 x 13.5
150
Perma Air (white)
43.0 x 22.0
550
Installation instructions
41
CUATRO-3 90
• If the appliance is to be placed against a bearing wall or against a wall containing
flammable material, an air gap of at least 20 mm should first be created.
Before it a false wall, 100 mm thick, must be built of masonry or aerated concrete.
• If the appliance is not placed against a bearing wall or a wall containing flammable
material, no false wall is necessary. Layers of insulation of at least 100-mm thickness
will then be sufficient (class A1, DIN 4102-compliant). See also section 3.3.
• After four weeks, your appliance will be ready for use.
3.3.5 Connecting the smoke outlet
The appliance comes with a detachable smoke outlet connection; Cuatro-3 90:
Ø200 mm (Ø198 mm external). This connection is intended for steel pipes, double/
single-skinned stainless steel (insulated) flues or double/single-skinned flexible stainless
steel flues.
After the appliance has been installed, it can be connected to the flue.
In order to be able to disassemble the smoke outlet connection, remove the flue gas
flap and the brake plate first. See Chapter 6 for the disassembly sequence: “Sequence
for replacing the interior of the appliance”.
•
42
Disassembling the smoke outlet connection.
Installation instructions
CUATRO-3 90
•
Pull the pipe of the appliance or the stainless steel (flexible) pipe downwards
through the appliance and secure it to the smoke outlet connection.
Stainless steel flexible
Fix with hose clamp
(Minimum 2 pieces
per connection.)
Installation instructions
43
CUATRO-3 90
Pipe of steel for the appliance
• Push the smoke outlet connection back upwards and secure it in place.
• Replace the brake plate and flue gas flap.
3.4
AIR-BOX / FAN BOX
3.4.1 INSTALLING AIR-BOX / FAN BOX
It is advisable to remove the complete door before installing the air-box / fan box; this
can be done by tilting the door upwards when in the open position and removing it.
The appliance is equipped with a dedicated ring (underneath the
appliance) to separate combustion and convection air, when the
appliance is originally ordered with an air-box / fan box.
(Supply of combustion air through the front appliance is, by
conseqence, no longer possible.)
In case the ring is not fitted, it is still possible to mount it through the
bottom of the appliance.
44
Installation instructions
CUATRO-3 90
Ring
The appliance can not be supported by the air-box / fan box !
Mount the 4 high adjustable feets on the apliance.
Installation instructions
45
CUATRO-3 90
Mount the fastening strips (L and R) at the underside of the appliance. Take care that
the strips are loosely fixed. Allow for a few millimeters space inbetween the strips and
the appliance
Attention ! The holes in the strips are not centered. Take care that the
short end is directed towards the outside of the appliance.
Short end directly towards the outside !
Knock out one round disc of the air-box using a broad, flat screwdriver. This is the
combustion air intake opening.
With fan
Without fan
Fan box
46
Combustion air-box
Installation instructions
CUATRO-3 90
In the combustion air section of the air-box / fan box there are 3 possible inlets for
combsution air available, i.e. under the box or at left or right side of the box.
In the convection air-section of the air box / fan box, the convention air intake is possible
at left or right side of the box.
From the back of the appliance, slide the air-box / fan box underneath the appliance.
Securely fix both fastening strips (L and R).
Place the included collar adapter in the combustion air and/or convection air intake
openings.
Installation instructions
47
CUATRO-3 90
Convection air inlet:
Knock out one circular-“break-away” discs of the airbox / fan box with a hammer;
1x circular disc left or right - back.
This will be the fan-convection air inlet.
Place the collar adapter (125 mm) on the convection air intake opening.
Combustion air inlet:
1x circular disc left, right or at the bottom of the air-box.
This will be the combustion air inlet.
Place the collar adapter (125 mm) on the combustion air intake opening.
Make the direct combustion air supply to the outside with a metal (flexible) tube
(Ø125 mm) and a grid on the outside wall.
Only replace the door in the appliance after fitting the complete appliance.
It is recommended to install a valve in the combustion air tube, to enable the closure
of this tube when the appliance is not used. Take care that the valve position must be
clearly visible at the outside of the tube.
If so desired, the appliance can be equipped with high adjustable feet (article no
330361 - set of high adjustable feet).
48
Installation instructions
CUATRO-3 90
Heat transfer when using convection fan
The heat transfer can be increased by transporting the heat with a convection fan.
With this system, hot air is blown into the room.
The convector fan built into the box is regulated by a built-in dimmer, with an integrated
on/off switch.
The fan doesn’t have any automatic regulation based on the appliance temperature.
Dimmer with integrated
ON - OFF switch.
For installation in built-in box.
Electrical connections dimmer.
Built-in box for dimmer.
Refer to the electrical wiring diagram supplied separately with the fan box, connect the
dimmer to the fan.
For maintenance, the convection fan can be
reached after removal of the complete floor
of the combustion.
Only replace the door in the appliance after fitting the complete appliance.
Installation instructions
49
CUATRO-3 90
3.5
•
•
•
•
•
•
50
PREPARATION / FUNCTION CHECK
Check the operation of the combustion air supply slider
Check the operation of the flue gas flap
Check if the combustion air supply opening(s) is (are) open
Check if the convection air supply opening(s) is (are) open
Check if the convection air escape openings are open
Check that the fan, once fitted, is in working order (if present)
Installation instructions
CUATRO-3 90
4
OPERATION
Cuatro-3 with fan set (option) and convection set (option) built into chimney
Figure 3: Operation
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Handle
Ceramic heat-proof glass
Locking slider for operating pin of flue gas flap
Operating pin of flue gas flap
Convection air outlet opening (appliance) (permanent)
Natural convection air outlet opening (2x grate) (chimney)
Convection air outlet opening (2x grate convection set) (chimney)
Wall dimmer (option) with integrated ON-OFF RPM control switch of the Perma Air ®
convection fan (option)
Combustion grate
Ashtray
Inlet opening (2x grate) (chimney) Ventilation air chimney / Convection air / Combustion air
Combustion air-supply slider (Combined operation for the primary, secondary and tertiary combustion
air-supply.)
Inlet opening (2x) combustion air from living-room. The two openings are only open when no
combustion air intake from underneath the appliance, nor from the outside is possible. This is
already decided during the installation of the appliance. NEVER close off open air intakes.
Convection air intake opening (2x). These two openings are only open when no convection air intake
from underneath the appliance, nor from the outside is possible. This is already decided during the
installation of the appliance. NEVER close off open air intakes.
Not visible on the drawing: Bend strips on brake plate holder for improving the flue draught in bad
draught conditions. See Chapter 4 “Using the appliance for the first time” in the Instructions for use &
maintenance manual.
Installation instructions
51
CUATRO-3 90
5
ANNUAL MAINTENANCE
It is essential that the appliance, the chimney and the
combustion air supply are cleaned and inspected
annually, by a Barbas-dealer/expert.
The safe operation of the appliance will thus remain
guaranteed.
Start with maintence 24 hours after the last burning period.
Recommended order for yearly maintenance:
•
Inside the appliance:
• Check the door seals. If necessary, replace the seals.
•
Temporarily remove the door, by opening it competely and lifting it upwards.
•
Remove the complete interior of the appliance (see Chapter 6) and carefully
clean all parts with a hand brush.
Emptying the ashtray.
•
Clean the glass on the inside of the door with glass spray or ceramic hob
cleaner.
•
If the glass is broken or cracked, it must be immediately replaced before
operating the appliance again.
Broken ceramic heat-resistant glass
may not be thrown away in a glass
container, but must be included in
normal household waste.
•
Check the grate and all interior plates on cracks.
If necessary, replace the parts.
‚
Chimney/flue channel:
• Sweep and inspect chimney. Check for cracks, loose parts, flue gas leakage
and overall condition of the chimney.
When in doubt use an inspection camera !
ƒ
Combustion air supply appliance:
• Check the combustion air supply route from the outside up to the appliance.
• Clean the combustion air supply inlet openings.
52
Installation instructions
CUATRO-3 90
„
Convection air (Ventilation air) appliance:
• Check the convection air route.
• Clean the convection air intake openings, flues and air escape openings.
• Clean the innerside of the fan box (option).
The convection fan can be reached after removal of the complete floor of the
combustion chamber / heating room.
…
Outside appliance:
• Clean the outside of the appliance with a dry lint free cloth.
• Wait for the appliance to cool down sufficiently before cleaning. Never use
scouring powder, aggressive cleaners or fire polish on the appliance.
• Any lacquer damage can be repaired with a BARBAS heat resistant paint spray
can. (Pay atention that the appliance is sufficiently cooled down !)
†
Ventilation house:
• Check whether the room where the appliance is installed is sufficiently
ventilated according to national and local regulations and standards.
• Ensure that as little dust, and as few particles of cigarette smoke, candles and
oil lamps as possible pollute the air in the room in which the appliance is used.
Heating of these particles by the convection system of the appliance could lead
to discoloration of the walls and ceiling. It is therefore very important to ensure
that the room in which the appliance is located is sufficiently ventilated.
‡
Last check appliance:
• In reversed order, place back all parts in the appliance.
• Place back the door on the appliance.
• Check the correct operation from the sliders and flaps. See Chapter 3.6:
Preparation / Function check.
ˆ
General:
• Parts:
Individual parts for replacement/accessories are available from your BARBAS
dealer. Use only original parts.
•
Modifications:
Introduced modifications to the appliance are not permitted.
Installation instructions
53
CUATRO-3 90
6
REPLACEMENT PARTS
6.1 CUATRO-3 75
with 3 sided frame (option)
with air-box / fan box (option)
Item no
Description
Number
1
Operating pin (for flue gas flap)
1
2
Side panel, right
1
3
Flue gas flap
1
4
Protective strip brake plate with bend strips
1
5
Brake plate / Retardant plate
1
6
Rear panel
1
7
Side panel, left
1
8
Grate
1
9
Bottom panel, rear
1
10
Bottom panel, front
1
11
Glass
1
12
13
®
Perma Air convection fan
Dimmer (built-in) Perma Air
1
®
1
When ordering, please give the serial number.
54
Installation instructions
CUATRO-3 90
Sequence for replacing the interior of the appliance:
• Remove the grate and the ashtray.
Although the heat resistant panels have been manufactured
with the greatest care, there is the possibility that some sharp
parts may stick out, possibly causing injuries.
We therefore urgently recommend wearing safety gloves when
handling the panels.
Disclaimer ! The person depicted on the photos showing the
handling of the panels is a professional engineer
who is aware of the risk of injury.
• Remove carefully the bottom panel (rear and front) by tilting it upwards and
removing it.
Installation instructions
55
CUATRO-3 90
• Remove the flue gas flap by lifting it slightly, tipping it backwards and removing it.
• Remove the protective strip from the brake plate.
• Remove the brake plate by lifting it slightly and removing it sloping to one side.
56
Installation instructions
CUATRO-3 90
• Remove carefully the left-hand side panel.
• Remove carefully the right-hand side panel using a broad, flat screwdriver.
Make sure the rear panels do not fall forwards !
• Remove carefully the rear panel, by lifting it upwards and remove it diagonally forward.
The entire interior is now disassembled.
The interior is reassembled in the reverse order.
Installation instructions
57
CUATRO-3 90
7
DIMENSIONS
7.1 CUATRO-3 90
•
•
without frame
without air-box / fan box (option)
* = External combustion air supply Ø125 mm
58
Installation instructions
CUATRO-3 90
7.2 CUATRO-3 90
•
•
with 3 sided 35 mm frame (option)
without air-box / fan box (option)
* = External combustion air supply Ø125 mm
Installation instructions
59
CUATRO-3 90
7.3 CUATRO-3 90
•
•
with 4 sided 35 mm frame (option
without air-box / fan box (option)
* = External combustion air supply Ø125 mm
60
Installation instructions
CUATRO-3 90
7.4 CUATRO-3 90
•
•
with 4 sided 35 mm frame (option
with air-box / fan box (option)
* With the high adjustable feet, the appliance can be installed till 350 mm above the floor
Installation instructions
61
CUATRO-3 90
8
TECHNICAL DATA
CUATRO-3 90
Combustion:
Measured in compliance with
EN 13229 : 2001 and EN 13229 - A2 : 2004
Fuel
Nominal output
Efficiency
Wood
16 kW
76%
Emissions (dry, at 13% O2, 273K, 1013 hPa):
Carbon monoxide (CO)
0.07%; 845 mg/m3 (STP, at 13% O2)
Dust
37 mg/Nm3 (STP, at 13% O2)
Total hydrocarbons (CxHy)
80 mg/m3 (STP, at 13% O2)
Nitrogen oxides (NOx)
121 mg/m3 (STP, at 13% O2)
Flue gas mass flow
Flue temperature
Chimney draught
Smoke outlet connection
Weight - Cuatro-3 90
- Fan box
- Air-box
13.5 g/s
329°C
0.12 mbar
Ø200 mm (Ø198 mm external)
161 kg
19 kg
3 kg
Inside:
Dimensions
- surface area (w x d)
- clear fire opening (h x w)
0.76 x 0.29 = 0.22 m2
335 x 758 mm
Side panels interior
Bottom interior
Inner lining
Retardant plate (brake plate)
Flue gas flap
Heat-resistant panels 1400 kg/m3, 1300°C
Heat-resistant panels 2000 kg/m3, 1300°C
Steel (heat-resistant and rust-proof)
Vermiculite insulation plates 700 kg/m3, 1100°C
Steel
Outside:
Construction
Doors
Sheet-steel casing
Flat door opening to left
Shutter with fixed handle
Operation:
• Handle for opening the door
• Combustion air supply slider
Single combined slide for controlling the
primary, secondary and tertiary air supply
Ash collection:
Ashtray with grate
62
Installation instructions
CUATRO-3 90
Combustion air supply:
At least 150 cm2 opening in the room where the fire is
located or a outside air supply opening of Ø125 mm
in wall/floor
Options:
Air-box / fan box with 230 VAC / 95 W fan (Perma Air ®)
for transport of heating air.
Rev control by built-in fanspeed controller
Convection set (1x or 2x)
Clean Air Act exemption:
Installation instructions
The appliance has been factory-fitted with an air
slide designed for use also in Smoke Control Areas.
63
CUATRO-3 90
9
WARRANTY TERMS
Interfocos
Warranty terms
Interfocos B.V. guarantees the quality of the supplied Barbas appliance and the quality
of the materials used. All Barbas appliances are developed and manufactured according
to the highest possible quality standards. If, despite all this, something should prove
amiss with the Barbas appliance you have purchased, Interfocos B.V. offers the following
manufacturer’s warranty.
Article 1: Warranty
1.1. If Interfocos B.V. determines that the Barbas appliance you have purchased is
defective as a result of a flaw in the construction or material, Interfocos B.V.
guarantees to repair or replace the appliance free of charge, without charging any
costs for labour or spare parts.
1.2. Repair or replacement of the Barbas appliance will be undertaken by Interfocos B.V.
or by a Barbas dealer as designated by Interfocos B.V.
1.3. This warranty is supplementary to the existing legal national warranty of Barbas
dealers and Interfocos B.V. in the country of purchase and is not intended to
restrict your rights and claims based on the applicable legal provisions.
Article 2: Warranty conditions
2.1. Should you wish to claim under the warranty, please contact your Barbas dealer.
2.2. Complaints should be reported as quickly as possible after they have manifested
themselves.
2.3. Complaints will only be accepted if they are reported to the Barbas dealer,
together with the serial number of the Barbas appliance which is stated on the front
of the instructions for use.
2.4. In addition, the original receipt (invoice, receipt, cash receipt) showing the date of
purchase must also be submitted.
2.5. Repairs and replacements during the warranty period do not give any entitlement
to an extension of the warranty period. After a repair or replacement of warranty
parts, the warranty period shall be deemed to have started on the date of
purchasing the Barbas appliance.
2.6. If a certain part is eligible for the warranty and the original part is no longer
available, Interfocos B.V. shall ensure that an alternative part of at least the
same quality shall be provided.
Article 3: Warranty exclusions
3.1. The warranty on the Barbas appliance ceases to be in effect if:
a. it is not installed according to the supplied installation instructions, and to
national and/or local regulations;
b. it has been installed, connected or repaired by a non-Barbas dealer;
64
Installation instructions
CUATRO-3 90
c.
d.
e.
3.2.
it has not be used or maintained according to the instructions for use;
it has been changed, neglected or roughly treated;
it has been damaged as a result of external causes (outside the appliance
itself), for example, lightning strike, water damage or fire;
In addition, the warranty lapses if the original purchase receipt shows any
change, deletion, removal or if it is illegible.
Article 4: Warranty area
4.1. The warranty is only valid in those countries where Barbas appliances are sold
through an official dealer network.
Article 5: Warranty period
5.1. This warranty will only be granted during the warranty period.
5.2. The body of the Barbas appliance is guaranteed for a period of 10 years against
construction and/or material faults, starting from the moment of purchase.
5.3. For other parts of the Barbas appliance, a similar warranty applies from the moment
of purchase for a period of one year.
5.4. For user parts such as glass, glass (cord), thermocouple and the interior of the
combustion chamber, a similar guarantee is given until after the first burning.
Article 6: Liability
6.1. A claim granted by Interfocos B.V. under this warranty does not automatically
imply that Interfocos B.V. also accepts liability for any possible damage.
The liability of Interfocos B.V. never extends further than that stated in these
warranty conditions. Any liability of Interfocos B.V. for consequential damage is
expressly excluded.
6.2. That stated in this provision is not valid if and to the extent that is derives from
a mandatory provision.
6.3. All agreements entered into by Interfocos B.V. are, unless specifically stated
otherwise in writing and to the extent that they are permitted based on applicable
law, subject to the Conditions of the Dutch Metal and Engineering Association
(METAALUNIEVOORWAARDEN), as filed with the registrar of the Court of
Rotterdam on 1 January 2014.
Interfocos B.V.
Hallenstraat 17
5531 AB Bladel
The Netherlands
Tel: +31-497339200
Email: [email protected]
Carefully retain the instructions for use; they show the serial number of the appliance.
You will need this if you wish to claim under the warranty.
Installation instructions
65
CUATRO-3 90
66
Installation instructions
Your Barbas dealer
04 - 221117 - 332965

advertisement

Key Features

  • Wood-burning insert/built-in appliance
  • Flue gas flap
  • Combustion air supply slider
  • Various installation options
  • Air-box/fan box option
  • Convection set option
  • Safety features

Frequently Answers and Questions

What types of fuel can I use in the barbas Cuatro-3 90 *?
This appliance is suitable for burning wood and wood briquettes. Do not use coal, liquid fuels, or fuel gel.
How do I install the barbas Cuatro-3 90 *?
The appliance must be installed by a Barbas dealer/specialist following local and national regulations. Refer to the detailed installation instructions in the manual.
Can I connect multiple appliances to a single chimney?
No, it's not allowed to connect several appliances to a single flue/chimney.
What are the ventilation requirements for the barbas Cuatro-3 90 *?
The appliance needs sufficient ventilation for combustion air. Use a grate with a minimum net opening of 150 cm2 in the outer wall or directly connect to an external air supply via an air-box/fan box.
What kind of insulation is recommended for the barbas Cuatro-3 90 *?
Use white unbound ceramic insulation wool. Avoid yellow bound materials like glass wool or rock wool, as they can release an irritating smell and are unsuitable for high temperatures.
How often should I have my chimney swept?
It's recommended to have your chimney swept at least once a year, and more often if you use your fire frequently.