Cabletron Systems 7F06-02 FDDI SmartSwitch User`s guide

Cabletron Systems 7F06-02 FDDI SmartSwitch User`s guide
Add to My manuals

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
Cabletron Systems 7F06-02 FDDI SmartSwitch User`s guide | Manualzz

7F06-02 FDDI SmartSwitch

Interface Module

User’s Guide

Only qualified personnel should perform installation procedures.

NOTICE

Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron

Systems to determine whether any such changes have been made.

The hardware, firmware, or software described in this manual is subject to change without notice.

IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL,

INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT

NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR

THE INFORMATION CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN

ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH

DAMAGES.

Copyright 1998 by Cabletron Systems, Inc., P.O. Box 5005, Rochester, NH 03866-5005

All Rights Reserved

Printed in the United States of America

Order Number: 9031672-02 January 1998

Cabletron Systems , SPECTRUM, and LANVIEW are registered trademarks and SmartSTACK ,

ELS10-26TX , FEPIM , FEPIM-TX and FEPIM-FX are trademarks of Cabletron Systems, Inc.

All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies.

FCC NOTICE

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications.

Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.

WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Printed on Recycled Paper

7F06-02 FDDI SmartSwitch Interface Module User’s Guide i

Notice

DOC NOTICE

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of

Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique

édicté par le ministère des Communications du Canada.

VCCI NOTICE

This is a Class A product based on the standard of the Voluntary Control Council for Interference by

Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.

CABLETRON SYSTEMS, INC. PROGRAM LICENSE AGREEMENT

IMPORTANT: Before utilizing this product, carefully read this License Agreement.

This document is an agreement between you, the end user, and Cabletron Systems, Inc. (“Cabletron”) that sets forth your rights and obligations with respect to the Cabletron software program (the

“Program”) contained in this package. The Program may be contained in firmware, chips or other media. BY UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME

BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES THE LICENSE AND

THE LIMITATION OF WARRANTY AND DISCLAIMER OF LIABILITY. IF YOU DO NOT

AGREE TO THE TERMS OF THIS AGREEMENT, PROMPTLY RETURN THE UNUSED

PRODUCT TO THE PLACE OF PURCHASE FOR A FULL REFUND.

ii 7F06-02 FDDI SmartSwitch Interface Module User’s Guide

Notice

CABLETRON SOFTWARE PROGRAM LICENSE

1.

LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement.

You may not copy, reproduce or transmit any part of the Program except as permitted by the

Copyright Act of the United States or as authorized in writing by Cabletron.

2.

OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the

Program.

3.

APPLICABLE LAW. This License Agreement shall be interpreted and governed under the laws and in the state and federal courts of New Hampshire. You accept the personal jurisdiction and venue of the New Hampshire courts.

EXCLUSION OF WARRANTY AND DISCLAIMER OF LIABILITY

1.

EXCLUSION OF WARRANTY. Except as may be specifically provided by Cabletron in writing, Cabletron makes no warranty, expressed or implied, concerning the Program (including its documentation and media).

CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO

YOU BY CABLETRON IN WRITING, EITHER EXPRESSED OR IMPLIED, INCLUDING

BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND

FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PROGRAM, THE

ACCOMPANYING WRITTEN MATERIALS, AND ANY ACCOMPANYING HARDWARE.

2.

NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL

CABLETRON OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER

(INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS,

PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL,

INCIDENTAL, CONSEQUENTIAL, OR RELIANCE DAMAGES, OR OTHER LOSS)

ARISING OUT OF THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT,

EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH

DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR

LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR

ON THE DURATION OR LIMITATION OF IMPLIED WARRANTIES, IN SOME

INSTANCES THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO

YOU.

UNITED STATES GOVERNMENT RESTRICTED RIGHTS

The enclosed product (a) was developed solely at private expense; (b) contains “restricted computer software” submitted with restricted rights in accordance with Section 52227-19 (a) through (d) of the

Commercial Computer Software - Restricted Rights Clause and its successors, and (c) in all respects is proprietary data belonging to Cabletron and/or its suppliers.

For Department of Defense units, the product is licensed with “Restricted Rights” as defined in the

DoD Supplement to the Federal Acquisition Regulations, Section 52.227-7013 (c) (1) (ii) and its successors, and use, duplication, disclosure by the Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at

252.227-7013. Cabletron Systems, Inc., 35 Industrial Way, Rochester, New Hampshire 03867-0505.

7F06-02 FDDI SmartSwitch Interface Module User’s Guide iii

Notice

DECLARATION OF CONFORMITY

Application of Council Directive(s): 89/336/EEC

73/23/EEC

Manufacturer’s Name: Cabletron Systems, Inc.

Manufacturer’s Address: 35 Industrial Way

PO Box 5005

Rochester, NH 03867

European Representative Name: Mr. J. Solari

European Representative Address: Cabletron Systems Limited

Nexus House, Newbury Business

Park

London Road, Newbury

Berkshire RG13 2PZ, England

Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC

EC Directive 73/23/EEC

EN 55022

EN 50082-1

EN 60950

Equipment Type/Environment: Networking Equipment, for use in a Commercial or Light

Industrial Environment.

We the undersigned, hereby declare, under our sole responsibility, that the equipment packaged with this notice conforms to the above directives.

Manufacturer Legal Representative in Europe

Full Name

Title

Location

Full Name

Title

Location iv 7F06-02 FDDI SmartSwitch Interface Module User’s Guide

CONTENTS

CHAPTER 1 INTRODUCTION

1.1

Using This Manual....................................................................... 1-1

1.2

The 7F06-02 Module ................................................................... 1-1

1.2.1

Cable Type and FPIMs ................................................... 1-2

1.2.2

7C03 MMAC SmartSwitch, the 7C04 Workgroup

SmartSwitch and the 7C04-R Workgroup

SmartSwitch.................................................................... 1-3

1.3

Features ...................................................................................... 1-3

1.3.1

FPIMs ............................................................................. 1-3

1.3.2

LANVIEW LEDs .............................................................. 1-3

1.3.3

Connectivity .................................................................... 1-4

1.4

Related Manuals.......................................................................... 1-4

1.5

Getting Help................................................................................. 1-5

CHAPTER 2 NETWORK REQUIREMENTS

2.1

FPIM Module Specifications ........................................................ 2-1

2.1.1

FPIM-00 and FPIM-01 .................................................... 2-1

2.1.2

FPIM-02 and FPIM-04 .................................................... 2-2

2.1.3

FPIM-05 and FPIM-07 .................................................... 2-3

CHAPTER 3 INSTALLATION/REMOVAL

3.1

Unpacking The 7F06-02 Module ................................................. 3-1

3.2

Installing FPIMs ........................................................................... 3-2

3.3

Installing/Removing The 7F06-02 Module................................... 3-3

3.3.1

Installing in the 7C03 SmartSwitch ................................. 3-3

3.3.2

Removing from the 7C03 SmartSwitch........................... 3-4

3.3.3

Installing in the 7C04 or 7C04-R

Workgroup SmartSwitch ................................................. 3-5

3.3.4

Removing the 7F06-02 from the 7C04 or 7C04-R Workgroup SmartSwitch ............................... 3-8

CHAPTER 4 TROUBLESHOOTING

4.1

Diagnostic and Monitoring System .............................................. 4-1

4.2

Port Receive LEDs ...................................................................... 4-2

4.3

Port Transmit LEDs ..................................................................... 4-2

4.4

A/B Link LEDs ............................................................................. 4-2

7F06-02 FDDI SmartSwitch Interface Module User’s Guide v

Contents

CHAPTER 5 TECHNICAL SPECIFICATIONS

5.1

Standards.....................................................................................5-1

5.2

EMI...............................................................................................5-1

5.3

EMC .............................................................................................5-1

5.4

Network Interfaces .......................................................................5-1

5.5

Safety ...........................................................................................5-2

5.6

Service .........................................................................................5-2

5.7

Physical........................................................................................5-2

5.7.1

Dimensions......................................................................5-2

5.7.2

Weight .............................................................................5-2

vi 7F06-02 FDDI SmartSwitch Interface Module User’s Guide

CHAPTER 1

INTRODUCTION

Welcome to Cabletron Systems 7F06-02 FDDI SmartSwitch Interface

Module User Guide . This guide is a simple reference for installing and using the 7F06-02 Module. Before installing this module, you should carefully read through this manual to gain a full understanding of its capabilities.

The 7F06-02 Module is a two-port FDDI module. This module connects to a network and the 7X00 SmartSwitch™ Control Module in the 7C03,

7C04 or 7C04-R MMAC SmartSwitch via a SmartSwitch bus.

1.1

USING THIS MANUAL

Chapter 1, Introduction , discusses the capabilities and special features of

Cabletron Systems 7F06-02 Module. This chapter also includes a list of related manuals.

Chapter 2, Network Requirements , contains a list of available FPIMs and the network requirements that should be considered before installing the 7F06-02 Module.

Chapter 3, Installation/Removal , contains instructions for installing and removing the 7F06-02 in the 7C03 MMAC SmartSwitch, the 7C04

Workgroup SmartSwitch or the 7C04-R Workgroup SmartSwitch.

Chapter 4, Troubleshooting , contains instructions for using LANVIEW ®

(Cabletron Systems built-in diagnostic and status monitoring system).

Chapter 5, Technical Specifications , provides detailed information about the physical characteristics of the 7F06-02 Module.

1.2

THE 7F06-02 MODULE

The 7F06-02 Module, shown in Figure 1-1, provides two fiber optic ports via front panel FPIM modules.

7F06-02 FDDI SmartSwitch Interface Module User’s Guide 1-1

Chapter 1: Introduction

1.2.1

Cable Type and FPIMs

The 7F06-02 module has two front panel connectors that interface to the

7X00 SmartSwitch Module through the chassis backplane. The front panel connections are standard Cabletron FPIMs. There are two FPIMs for each channel. These FPIMs allow the use of single mode or multimode fiber cable with MIC or SC type connectors and twisted pair cable, either shielded or unshielded.

7F06-02

SP

A

I

1

F

D

D

SN

P

S

A

B

B

A

F

D

D

I

2

P

S

A

B

B

Figure 1-1 7F06-02 Module

1-2 7F06-02 FDDI SmartSwitch Interface Module User’s Guide

Chapter 1: Introduction

1.2.2

7C03 MMAC SmartSwitch, the 7C04 Workgroup

SmartSwitch and the 7C04-R Workgroup

SmartSwitch

The 7F06-02 Module is designed to be installed in the 7C03 MMAC

SmartSwitch, the 7C04 Workgroup SmartSwitch or the 7C04-R

Workgroup SmartSwitch.

The modular design of the 7C03 MMAC SmartSwitch allows other modules that support Ethernet, Fast Ethernet, ATM, FDDI, or Token Ring to be used with the 7F06-02 Module. These modules provide the capability to share data without the use of external bridges or routers.

The 7C03 MMAC SmartSwitch is a unique module that can be installed in an MMAC Series chassis. The 7C04 Workgroup SmartSwitch and the

7C04-R Workgroup SmartSwitch are stand-alone chassis that provide the same functions.

1.3

FEATURES

The 7F06-02 Module provides two FDDI ports via front panel FPIMs.

The 7F06-02 Module includes the following features:

1.3.1

FPIMs

The front panel connections are standard Cabletron FPIMs. These

FPIMs allow the use of single mode or multimode fiber cable with

MIC or SC type connectors.

1.3.2

LANVIEW LEDs

The 7F06-02 uses LANVIEW, Cabletron Systems built-in visual diagnostic and status monitoring system. With LANVIEW LEDs, you can quickly identify, at a glance, the status of the device connected to a port on the 7F06-02 Module.

7F06-02 FDDI SmartSwitch Interface Module User’s Guide 1-3

Chapter 1: Introduction

1.3.3

Connectivity

The 7F06-02 Module has one backplane connection and two sets of A/B front panel FPIM connections. The backplane connection provides power to the 7F06-02 Module and a channel for communication with the 7X00

SmartSwitch Control Module. The two front panel FPIMs provide FDDI connections, allowing the use of single mode or multimode fiber cable with MIC or SC type connectors.

1.4

RELATED MANUALS

The following Cabletron Systems manuals supplement the procedures and other technical data provided in this manual. The procedures will be referenced, where appropriate, but will not be repeated.

7X00 SmartSwitch Control Module User’s Guide

7F06-02 Local Management Appendix

7C03 MMAC SmartSwitch Installation Guide

7C04 Workgroup SmartSwitch Installation Guide

7C04-R Workgroup SmartSwitch Installation Guide

1-4 7F06-02 FDDI SmartSwitch Interface Module User’s Guide

Chapter 1: Introduction

1.5

GETTING HELP

If you need additional support related to this device, or if you have any questions, comments, or suggestions concerning this manual, contact the

Cabletron Systems Global Call Center:

Phone

Internet mail

FTP

Login

(603) 332-9400 [email protected]

ctron.com (134.141.197.25) anonymous

BBS

Password your email address

(603) 335-3358

Modem setting

8N1: 8 data bits, No parity, 1 stop bit

For additional information about Cabletron Systems or our products, visit our World Wide Web site: http://www.cabletron.com/

For technical support, select:

Service and Support.

Before calling the Cabletron Systems Global Call Center, have the following information ready:

• Your Cabletron Systems service contract number

• A description of the failure

• A description of any action(s) already taken to resolve the problem

(e.g., changing mode switches, rebooting the unit, etc.)

• The serial and revision numbers of all involved Cabletron Systems products in the network

• A description of your network environment (layout, cable type, etc.)

• Network load and frame size at the time of trouble (if known)

• The device history (i.e., have you returned the device before, is this a recurring problem, etc.)

• Any previous Return Material Authorization (RMA) numbers

7F06-02 FDDI SmartSwitch Interface Module User’s Guide 1-5

Chapter 1: Introduction

1-6 7F06-02 FDDI SmartSwitch Interface Module User’s Guide

CHAPTER 2

NETWORK REQUIREMENTS

Before installing Cabletron Systems 7F06-02 Module, review the network requirements outlined in this chapter. All requirements included in this chapter should be met to ensure satisfactory performance of the 7F06-02

Module. Failure to do so may result in unsatisfactory network performance.

2.1

FPIM MODULE SPECIFICATIONS

This module uses Fiber Port Interface Modules (FPIM) to provide front panel cable connections. The FPIMs are user-installable. Refer to Section

3.2, Installing FPIMs.

2.1.1

FPIM-00 and FPIM-01

The FPIM-00 and FPIM-01 provide a multimode fiber connection. The

FPIM-00 uses a MIC style connector and the FPIM-01 uses an SC type

connector. The specifications for both devices are listed in Table 2-1,

while the transmitter power parameters are provided in Table 2-2.

Parameter

Table 2-1 FPIM-00 and FPIM-01 Specifications

Typical Value

-30.5 dBm

Worst

Case

-28.0 dBm —

Worst

Case

Budget

Receive

Sensitivity

Peak Input

Power

-7.6 dBm -8.2 dBm —

Typical

Budget

7F06-02 FDDI SmartSwitch Interface Module User’s Guide 2-1

Chapter 2: Network Requirements

Table 2-2 Transmitter Power Parameters

Parameter Typical Value

50/125

µ m fiber

62.5/125

µ m fiber

100/140

µ m fiber

Error Rate

-13.0 dBm

-10.0 dBm

-7.0 dBm

Better than 10 -10

Worst

Case

Worst

Case

Budget

-15.0 dBm 13.0 dB

-12.0 dBm 16.0 dB

-9.0 dBm 19.0 dB

Typical

Budget

17.5 dB

20.5 dB

23.5 dB

The link distance is up to 2 kilometers on the multimode fiber optic cable as specified by ANSI MMF-PMD.

2.1.2

FPIM-02 and FPIM-04

The FPIM-02 has an RJ-45 connector supporting an Unshielded Twisted

Pair (UTP) connection. The FPIM-04 has an RJ-45 connector supporting a Shielded Twisted Pair (STP) connection. The pinouts for both are listed

in Table 2-3.

3

4

1

2

Pin Number

Table 2-3 FPIM-02 and FPIM-04 Pinouts

Represents

Transmit+

Transmit-

NA

NA

5

6

7

8

Pin Number Represents

NA

NA

Receive+

Receive-

The link distance is up to 100 meters on unshielded twisted pair cable as specified by ANSI TP-PMD.

2-2 7F06-02 FDDI SmartSwitch Interface Module User’s Guide

Chapter 2: Network Requirements

2.1.3

FPIM-05 and FPIM-07

The FPIM-05 and FPIM-07 provide a single-mode fiber connection. The

FPIM-05 uses a MIC style connector and the FPIM-07 uses an SC type

connector. The specifications for both devices are listed in Table 2-4.

Table 2-4 FPIM-05 and FPIM-07 Specifications

Parameter Typical Minimum Maximum

Transmitter Peak Wave Length 1300 nm

Spectral Width 60 nm

Rise Time

Fall Time

Duty Cycle

Bit Error Rate

3.0 nsec

2.5 nsec

50.1%

Better than

10 -10

-

1270 nm

2.7 nsec

2.2 nsec

49.6%

1330 nm

100 nm

5.0 nsec

5.0 nsec

50.7%

The link distance is up to 40 kilometers (max) and 25 kilometers (typical) on single-mode, fiber-optic cable as specified by ANSI SMF-PMD.

7F06-02 FDDI SmartSwitch Interface Module User’s Guide 2-3

Chapter 2: Network Requirements

2-4 7F06-02 FDDI SmartSwitch Interface Module User’s Guide

CHAPTER 3

INSTALLATION/REMOVAL

This chapter contains instructions for unpacking and installing the 7F06-2

Module in the:

• 7C03 MMAC SmartSwitch

• 7C04 Workgroup SmartSwitch

• 7C04-R Workgroup SmartSwitch

Also included in the chapter are instructions for installing the front panel

FPIMs.

3.1

UNPACKING THE 7F06-02 MODULE

Unpack the 7F06-02 Module by using the following steps:

Before unpacking the 7F06-02 module, attach the antistatic wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package.

1. Carefully remove the module from the shipping box. (Save the box and packing materials in the event the module must be reshipped.)

2. Remove the module from the plastic bag. Observe all precautions to prevent damage from Electrostatic Discharge (ESD).

3. Carefully examine the module and check for damage. If damage exists, DO NOT install the module; contact Cabletron Systems Global

Call Center.

7F06-02 FDDI SmartSwitch Interface Module User’s Guide 3-1

Chapter 3: Installation/Removal

3.2

INSTALLING FPIMS

Before installing the 7F06-02 module, attach the antistatic wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package.

The 7F06-02 module is shipped without FPIMs. To install an FPIM, follow the procedure below:

1. Remove the module if it is installed in the 7C03 MMAC SmartSwitch chassis by reversing the procedure in Section 3.3.

2. Remove the blank front cover over the FPIM slot.

3. Install the FPIM as shown in Figure 3-1. Ensure that the rear connector

is seated firmly before tightening the two mounting screws.

Figure 3-1 Installing an FPIM

3-2 7F06-02 FDDI SmartSwitch Interface Module User’s Guide

Chapter 3: Installation/Removal

3.3

INSTALLING/REMOVING THE 7F06-02 MODULE

The following procedure details the installation and removal procedure for the 7F06-02 module.

3.3.1

Installing in the 7C03 SmartSwitch

The 7F06-02 Module is installed in the 7C03 MMAC SmartSwitch

using the following steps and referring to Figure 3-2.

Note: The left-most slot in the 7C03 MMAC SmartSwitch is reserved for the 7X00 SmartSwitch Module.

Note: Before installing the 7F06-02 module, attach the antistatic wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package.

1. As a precaution, power down the MMAC 8 before beginning the installation or removal of any modules. At the very minimum, the

7C03 must be pulled to disconnect it from the power source. Damage to modules may result if this procedure is not followed.

2. Remove the blank panel covering the slot in which the module will be installed. All other slots must remain covered to ensure proper airflow and cooling.

3. Install the module by sliding it into slots as shown in Figure 3-2.

Ensure that the printed circuit board (PCB) is between the card guides, slides in straight, and engages the backplane connectors properly.

4. Using a slotted screwdriver, tighten the top and bottom screws.

CPU

SN

Card

Guides

Figure 3-2 Installing the 7F06-02 Module in the

7C03 MMAC SmartSwitch

7F06-02 FDDI SmartSwitch Interface Module User’s Guide 3-3

Chapter 3: Installation/Removal

3.3.2

Removing from the 7C03 SmartSwitch

The 7F06-02 Module inserted in the 7C03 MMAC SmartSwitch can be removed upon proper removal of power. Follow the steps below and refer

to Figure 3-3 to remove the module.

Note: Before removing the 7F06-02 module, attach the antistatic wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package.

1. As a precaution, power down the MMAC 8 before beginning the installation or removal of any modules. At the very minimum, the

7C03 must be pulled to disconnect it from the power source. Damage to modules may result if this procedure is not followed.

2. Use a slotted screwdriver to loosen the two screws that secure the module to the chassis.

3. Locate the two ejector tabs on the module (to the right of the screws on the top and bottom of the module).

4. Simultaneously press down on the bottom ejector tab and up on the top ejector tab until the module ejects from the backplane.

5. Grasp both ejector tabs and carefully slide the module out of the chassis.

SN

CPU

Screw

Ejector Tab

Screw

Ejector Tab

3-4

Figure 3-3 Removing the 7F06-02 Module from the 7C03 MMAC

SmartSwitch

7F06-02 FDDI SmartSwitch Interface Module User’s Guide

Chapter 3: Installation/Removal

3.3.3

Installing in the 7C04 or 7C04-R Workgroup

SmartSwitch

The 7F06-02 Module is installed in the 7C04 or 7C04-R Workgroup

SmartSwitch using the following steps and referring to Figures 3-4 and

3-5.

Notes: The top slot in the 7C04 Workgroup SmartSwitch is reserved for the 7X00 SmartSwitch Module.

The bottom slot in the 7C04-R Workgroup SmartSwitch is reserved for the 7X00 SmartSwitch Module.

Therefore, before installing the 7F06-02 module, attach the wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package.

1. As a precaution, power down the MMAC 8 before beginning the installation or removal of any modules. At the very minimum, the

7C04 or 7C04-R must be pulled to disconnect it from the power source. Damage to modules may result if this procedure is not followed.

2. Remove the blank panel covering the slot in which the module will be installed. All other slots must remain covered to ensure proper airflow and cooling.

3. Install the module by sliding it into slots as shown in the appropriate figure. Ensure that the printed circuit board (PCB) is between the card guides, slides in straight, and engages the backplane connectors properly.

4. Using a slotted screwdriver, tighten the top and bottom screws.

7F06-02 FDDI SmartSwitch Interface Module User’s Guide 3-5

Chapter 3: Installation/Removal

1

2

SN

3

4

Screw

Ejector Tab

Figure 3-4 Installing the 7F06-02 Module in the 7C04 Workgroup

SmartSwitch

3

2

1

4

FANS

Card

Guides

3-6

Figure 3-5 Installing the 7F06-02 Module in the 7C04-R Workgroup

SmartSwitch

7F06-02 FDDI SmartSwitch Interface Module User’s Guide

Chapter 3: Installation/Removal

3.3.4

Removing the 7F06-02 from the 7C04 or 7C04-R

Workgroup SmartSwitch

The 7F06-02 Module, inserted in the 7C04 or the 7C04-R

Workgroup SmartSwitch, can be removed whenever necessary. Follow the steps below and refer to Figures 3-6 or 3-7 to remove the module.

Note: Before removing the 7F06-02 module, attach the antistatic wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package.

1. As a precaution, power down the MMAC 8 before beginning the installation or removal of any modules. At the very minimum the 7C04 or 7C04-R must be pulled to disconnect it from the power source.

Damage to modules may result if this procedure is not followed.

2. Use a slotted screwdriver to loosen the two screws that secure the module to the chassis.

3. Locate the two ejector tabs on the module (below the screws on the left and right end of the module).

4. Simultaneously press left on the left ejector tab and right on the right ejector tab until the module ejects from the backplane.

5. Grasp both ejector tabs and carefully slide the module out of the chassis.

Screws

3

4

1

2

Ejector Tabs

Figure 3-6 Removing the 7F06-02 Module from the 7C04 Workgroup

SmartSwitch

7F06-02 FDDI SmartSwitch Interface Module User’s Guide 3-7

Chapter 3: Installation/Removal

Screws

3

2

1

4

FANS

SN

Ejector Tabs

Figure 3-7 Removing the 7F06-02 Module from the 7C04-R Workgroup

SmartSwitch

3-8 7F06-02 FDDI SmartSwitch Interface Module User’s Guide

CHAPTER 4

TROUBLESHOOTING

4.1

DIAGNOSTIC AND MONITORING SYSTEM

The 7F06-02 Module uses LANVIEW, Cabletron Systems’ built-in visual diagnostic and status monitoring system.

With LANVIEW LEDs the status of each transmit and receive port on the

7F06-02 Module can be determined, at a glance. This section discusses the function and purpose of the LEDs on the 7F06-02 Module.

Figure 4-1 shows the LANVIEW LEDs of the 7F06-02 Module.

7F06-02

SP

Primary

Ring

Secondary

Ring

A

F

D

D

I

1

P

S

A

B

B

A Link Status

B Link Status

Receive

Transmit

Figure 4-1 LANVIEW LEDs

7F06-02 FDDI SmartSwitch Interface Module User’s Guide 4-1

Chapter 4: Troubleshooting

4.2

PORT RECEIVE LEDS

Table 4-1 indicates the state of the receive port.

LED Color

Yellow (Flashing)

Off

Table 4-1 Port Receive LEDs

State

Data activity (flashing to steady on indicates rate)

No activity, port can be disabled or enabled

4.3

PORT TRANSMIT LEDS

Table 4-2 indicates the state of the transmit port.

LED Color

Green (Flashing)

Off

Table 4-2 Port Transmit LEDs

State

Data activity (flashing to steady on indicates rate)

No activity, port can be disabled or enabled

4.4

A/B LINK LEDS

Table 4-3 indicates the state of the A/B Link LEDs.

A P

Green N/A

Green Green

Green Green

Table 4-3 Link LEDs

S B State

N/A

Off

Green Ports Enabled & Active

Green THRU A, MAC on Primary,

Secondary Bypasses Board

Yellow Green THRU A, MAC on Primary,

No MAC on Secondary

4-2 7F06-02 FDDI SmartSwitch Interface Module User’s Guide

Chapter 4: Troubleshooting

A

Green

Green

Green

Green

Off

P

Green Green

Green Yellow

Yellow Green

Yellow Yellow

Green Green

Green Off

Green Red

Yellow Off

Red

Yellow

Yellow

Off

Off

Table 4-3 Link LEDs (Continued)

S B State

Red

Red

Red

Off

Red

Off

Green Green THRU B, MAC on Secondary,

Primary Bypasses Board

Green Green THRU B, MAC on Secondary,

No MAC on Primary

Off Green THRU, No MAC on Primary,

Secondary Bypasses Board

Yellow Green THRU, No MAC on Secondary,

Primary Bypasses Board

Red

Red

Yellow

Yellow

WRAP A, MAC on Primary

WRAP A, No MAC on Primary

Off

Green

Green

Green

Green

Green

WRAP B, MAC on Primary

WRAP B, No MAC on Primary

WRAP AB, MAC on Primary

BYPASS Primary & Secondary

Yellow PCM did not complete, Not

Red

TWISTED A-A, B-B

Active

Ports Disabled

7F06-02 FDDI SmartSwitch Interface Module User’s Guide 4-3

Chapter 4: Troubleshooting

4-4 7F06-02 FDDI SmartSwitch Interface Module User’s Guide

CHAPTER 5

TECHNICAL SPECIFICATIONS

This chapter includes the technical specifications for 7F06-02 module.

Cabletron Systems reserves the right to change these specifications at any time without notice.

5.1

STANDARDS

IEEE 802.1D

IEEE 802.3i 10BASE-T

5.2

EMI

The EMI requirements of:

• FCC Part 15 Class A

• EN 55022 Class A

• VCCI Class I

5.3

EMC

The EMC requirements of:

• EN 50082-1

• IEC 801-2 ESD

• IEC 801-3 Radiated susceptibility

• IEC 801-4 EFT

5.4

NETWORK INTERFACES

Two FPIMs

7F06-02 FDDI SmartSwitch Interface Module User’s Guide 5-1

Chapter 5: Technical Specifications

5.5

SAFETY

It is the responsibility of the person who sells the system to which the module will be a part to ensure that the total system meets allowed limits of conducted and radiated emissions.

This equipment meets the safety requirements of:

• UL 1950

• CSA C22.2 No. 950

• EN 60950

• IEC 950

5.6

SERVICE

MTBF:

MTTR:

5.7

PHYSICAL

>200,000 hours

<0.5 hour

5.7.1

Dimensions

31.1D x 22.9 H x 3.1 W centimeters

(12.3 D x 9.0 H x 1.2 W inches)

5.7.2

Weight

Unit:1.8 kgs. (4 lbs.)

Shipping:4.5 kgs. (10 lbs.)