Balboa | bba | BP2100G1 Tech Sheet - Balboa Water Group

BP2100G1 Tech Sheet
Customer:
Balboa Water Group
Part Number:
56389-02
800 Incoloy 3kW
56390-02
825 Incoloy 3kW
56391-02
Titanium 3kW
56587
800 Incoloy 2kW
Custom Box Overlay
□
Box Overlay Part Number N/A
CE System Model:
BP21-BP2100G1-RCA3.0K
Software Version ID:
M100_225 V20.0
Software Version:
20.0
File Name:
BP2100_20.0_BP2100G1_18.hex
Configuration Signature:
EBCE9FD8
Eng. Project Number:
4132
Base PCBA:
56392-02 for systems 56389-02, 56390-02, 56391-02
56588 for system 56587
Control Panels:
TP600CE
version 2.7 or later
TP600 (non-CE) should not be used.
TP800
version 3.1 or later (Version 3.13 or later required for bba™)
TP900
version 3.1 or later (Version 3.13 or later required for bba™)
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
1
56389-02/56390-02/56391-02/56587_97_E
08-06-14
System Revision History
Part #
EPN
Date
Originator Changes Made
56389
3936
12-07-12
BWG
Initial Release BP2100G1
4008
01-31-13
BWG
Add Setup 18. Add TP600 support.
4132
09-12-13
BWG
Update to latest software version.
4132
01-30-14
BWG
Updated to latest software version, adding topside-intergrated bba™ support. Released to production. Add 2kW model.
56390
56391
56389-01
56390-01
56391-01
56389-02
56390-02
56391-02
56389-02
56390-02
56391-02
56587
bba™ (Balboa Bluetooth Amp) connection is documented separately.
bba™ is only integrated into graphic display panels (TP800, TP900 and spaTouch™). With TP600 the Aux button operation of bba™ must be used.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
2
56389-02/56390-02/56391-02/56587_97_E
08-06-14
Basic Functions Setup 1-18
Power Requirements:
Single Service [3 wires (line, neutral, ground)]
230VAC, 50/60Hz*, 1þ, 32A, (Circuit Breaker rating = 40A max.)
Dual Service N/A
3-Service [5 wires (line 1, line 2, line 3, neutral, ground)]
400VAC, 50/60Hz*, 3þ, 16A, (Circuit Breaker rating = 20A max each phase line.)
IMPORTANT - Service must include a neutral wire, with a line to neutral voltage of 230VAC.
*BP systems automatically detect 50Hz vs 60Hz.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
3
56389-02/56390-02/56391-02/56587_97_E
08-06-14
Basic Functions Setup 1-18
System Ouputs:
Pump 1
230VAC
2-Speed
12A max
15-minute timer for High Speed, 15-Minute timer for Low Speed
1-Speed in Setups 12, 14, 17
This is the heater pump in Setups 1–6, 15, 18
Must deliver 20 GPM through heater
Pump 2
230VAC
2-Speed
12A max
15-minute timer
1-Speed in Setups 5, 6, 11–14, 17, 18
Pump 3
230VAC
2-Speed
12A max
15-minute timer
2-Speed in Setups 1, 7
1-Speed in Setups 2, 5, 6, 8, 11–16
Unused in Setups 3, 4, 9, 10, 17, 18
Blower
230VAC
1 Speed
4A max
15-minute timer
Unused in Setups 1, 2, 4, 6–8, 10, 13, 14
Circ Pump
230VAC
1-Speed
2A max
Programmable Filtration Cycles + Polling
This is the heater pump in Setups 7–14, 16, 17
Must deliver 20 GPM through heater
Ozone
230VAC
Spa Light
10VAC
A/V (Stereo) 230VAC
Heater
.5A max
Slaved to Circ Pump in Setups 7-14, 16, 17
Independent in Setups 1-6, 15, 18
On/Off
1A max
240-minute timer.
Hot
5A max
Always on
3.0kW @ 240VAC max
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
4
56389-02/56390-02/56391-02/56587_97_E
08-06-14
Hardware Setup
Wiring Diagram
BP2100G1 – PN 56389-02
J43 TO J13 (BLOWER ON J14)
IN SETUPS 3, 5, 9, 11, 12, 17, 18
J60 J41
J51
J52
J98
4
J53
J45
J79
J54
J77
J75
J78
J110
J18
OZONE
J20
AUX**
J34
MAIN
230V
115V
J35
MAIN
J108 J107
4
J22
K3
J49
K5
3
2
J44
J58
J25
3
J15
LIGHT
K7
F4 3A SLO-BLOW
J111
J29
VAC
J23
SERIAL
ON S1
J40
HTR
DISBL
J28
REMOTE
AUX
DEVICE
2 SPD*
PUMP 3
J17
J16
SENSOR B
3.0 kW HEATER
**J14 (AUX) IS:
2-SPEED PUMP 2 IN SETUPS 1, 2, 4, 7, 8, 10, 15, 16
1-SPEED PUMP 2 IN SETUPS 6, 13, 14
1-SPEED BLOWER IN SETUPS 3, 5, 9, 11, 12, 17, 18
HEIZELEMENT
RADIATEUR
EXPANDER
X-P332
W1
J1
AUX
FRZ
230V
1þ
1x32A
SENSOR A
LOCATION
J1 ON RT
EXPANDER
J8
AUX
J31
10
GND
J11
J27
WIFI
TRANSCEIVER
J34 OR J35
VOLTS
230V
AMPS
12A†
MAX
FROM
W1 ON
EXPANDER
J26 J30
J48
J7
2
J5
AUX
J91
J101
J6
J37 J72
J4 J42
J1 J3
J47 J61
J36
J12
J88
J62
3
GRN
J19
115V
TP (MAIN) PANELS
J34 OR J35
IR RECEIVER
OR
RF RECEIVER
J50
K8
T1
F3 0.125A SLO-BLOW
K6
K1
2
BRN
J24
J109
1
BLU
K12
F8 30A
1
J14
J13
EXPANDER
F6 30A
J43
J32
F7 10A 250VAC
J56
J57
J55
J59
J39
J10
CIRC PUMP
J38
K2
TB1
J21
K9
J81
J46
J33
K4
F2 10A 250VAC
PUMP 1
J9
A/V HOT
J25=HTR1
J26=HTR2
J27=HTR3
J30=TEST
J31=CE
HTR
SEL
08-06-14
RIGHT
EXPANDER
BOARD
J6
F1 30A
J7
TO
GROUP 2
J1
J5 (A1-A4)
OR
J8 (A5-A8)
FROM
J6 ON
EXPANDER
TO
GROUP 3
J53
† WHEN USING SPLITTER WITH
EXPANDER BOARD BOTH OUTPUTS
NEED TO ADD UP TO 20A MAX.
NETZSTROMVERSORGUNG
2-GESCHW.-PUMPE 3*
ALIMENTATION POMPE 3
A 2 VITESSES*
*EXPANDER BOARD IS:
2-SPEED PUMP 3 IN SETUPS 1, 7
1-SPEED PUMP 3 (ONLY) IN SETUPS 2, 6, 8, 13, 14
1-SPEED PUMP 3 AND 1-SPEED BLOWER (WITH SPLITTER & IN-LINE FUSE)
IN SETUPS 15, 16
1-SPEED PUMP 2 AND 1-SPEED PUMP 3 IN SETUPS 5, 11, 12
2-SPEED PUMP 2 IN SETUPS 3, 9
1-SPEED PUMP 2 IN SETUP 17, 18
UNUSED IN SETUPS 4, 10
PART A
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
5
56389-02/56390-02/56391-02/56587_97_E
08-06-14
Hardware Setup
Settings
SINGLE SERVICE 230V 1þ / 1x32A, THREE-SERVICE 230V 1þ / 3x16A
2-SPEED
2-SPEED
2-SPEED
2-SPEED
2-SPEED
2-SPEED
2-SPEED
2-SPEED
2-SPEED
2-SPEED
2-SPEED
1-SPEED
2-SPEED
1-SPEED
2-SPEED
2-SPEED
1-SPEED
2-SPEED
2-SPEED
2-SPEED
2-SPEED
2-SPEED
1-SPEED
1-SPEED
2-SPEED
2-SPEED
2-SPEED
2-SPEED
1-SPEED
1-SPEED
1-SPEED
1-SPEED
2-SPEED
2-SPEED
1-SPEED
1-SPEED
2-SPEED
1-SPEED
NONE
NONE
1-SPEED
1-SPEED
2-SPEED
1-SPEED
NONE
NONE
1-SPEED
1-SPEED
1-SPEED
1-SPEED
1-SPEED
1-SPEED
NONE
NONE
NONE
NONE
1-SPEED
NONE
1-SPEED
NONE
NONE
NONE
1-SPEED
NONE
1-SPEED
1-SPEED
NONE
NONE
1-SPEED
1-SPEED
1-SPEED
1-SPEED
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
PUMP 1 LOW TIMEOUT IS 15 MINUTES.
‡SETUPS 5, 11, 12, 15 AND 16 REQUIRE BP2X-WIRE KIT PN30893
***SETUPS 15 AND 16 REQUIRE ADDITIONAL FUSED ADAPTER FOR BLOWER OUTPUT
FOR SUPPLY CONNECTIONS,
USE CONDUCTORS SIZED ON THE
BASIS OF 60°C AMPACITY BUT
RATED MINIMUM OF 90°C.
USE COPPER CONDUCTORS ONLY.
EMPLOYER UNIQUEMENT
DES CONDUCTEURS DE CUIVRE.
*SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION.
230V 3þ
3x16A
S2
12A† MAX
S1
6
3
GRN
4
SPLITTER OPTIONS:
IN SETUPS 5, 11, 12
S1 = PUMP 2
S2 = PUMP 3
J53
2
J38
3
J58
J1
J6
4
IN SETUPS 15, 16
S1 = PUMP 3
S2 = FUSED ADAPTER
‡ OPTIONAL BP2X-WIRE KIT PN 30893
56389-02/56390-02/56391-02/56587_97_E
J46
2
3 BRN
12A† MAX
TORQUE RANGE FOR
MAIN TERMINAL BLOCK (TB1):
27-30 IN. LBS.
(31.1-34.5 kg cm)
1
TB1
BLU
2 BRN
10A
***FUSED ADAPTER
BLOWER
SETUPS
15 & 16
ONLY
SPLITTER IS UNUSED
(REMOVED) IN
SETUPS 1-4, 6-10,
13, 14, 17, 18
BP2100G1 – PN 56389-02
08-06-14
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
A2
A5
1 BRN
TO
S2
INSTEAD OF
SETUP #1,
THIS SYSTEM IS
CONFIGURED IN
SETUP #:
J60 J41
OFF
1
RED
TEMP SCALE
WHITE
+ POLLING
+ POLLING
BLOWER
GREEN
POLLING
POLLING
POLLING
POLLING
POLLING
POLLING
POLLING
POLLING
PUMP 3
BLACK
PROGRAMMABLE
PROGRAMMABLE
+
+
+
+
+
+
+
+
PUMP 2
WHITE
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
NONE
NONE
NONE
NONE
NONE
NONE
FILTRATION
FILTRATION
FILTRATION
FILTRATION
FILTRATION
FILTRATION
FILTRATION
FILTRATION
NONE
FILTRATION
FILTRATION
NONE
PUMP 1
GREEN
1
2
3
4
5‡
6
7
8
9
10
11‡
12‡
13
14
15‡***
16‡***
17
18
CIRC PUMP
TEST MODE ON
ADD 1 HS PUMP WITH HEAT
ADD 2 HS PUMPS WITH HEAT
ADD 4 HS PUMPS WITH HEAT
SPECIAL AMPERAGE RULE B
MEMORY RESET*
5 MIN HTR COOLDOWN (GAS)
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
J51
J52
J98
SETUP #
TO
J1 ON
EXPANDER
TO RED AC
(GROUP 2)
ON MAIN BOARD
SWITCHBANK S1 ON
TEST MODE OFF
DON’T ADD 1 HS PUMP W/HTR
DON’T ADD 2 HS PUMPS W/HTR
DON’T ADD 4 HS PUMPS W/HTR
SPECIAL AMPERAGE RULE A
STORE SETTINGS*
1 MIN HTR COOLDOWN (ELEC)
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
J37 J72
J4 J42
J1 J3
J47 J61
J33
J40
J5, J8
SWITCHBANK S1 OFF
230V 1þ
1x32A
J36
J12
J88
J62
J15
J21
J32
DEVICE
NETZSTROMVERSORGUNG 2-GESCHW.-PUMPE 1 ALIMENTATION POMPE 1 A 2 VITESSES 2-SPEED PUMP 1
AUX**
AUX LINE 1 CONNECTION
J19 to J43
10V BELEUCHTUNG ECLAIRAGE BAIN HYDRO SPA LIGHT
KREISLAUF PUMPE POMPE DE CIRCULATION CIRC PUMP
(SETUPS 7-14, 16)
OZONGENERATOR GENERATOROZONE OZONE GENERATOR
CIRC AND OZONE LINE 1 CONNECTION
J81 to J59
TV / AV
IR RECIEVER
AUX PANEL(S) - AX10, AX20, AX30, AX40
J78
J45
J79
J54
J77
J75
LOCATION
J9
J14
08-06-14
PART B
Setup Reference Table
Setup #
Circ Pump
Pump 1
Pump 2
Pump 3
Blower
Temp Scale
1
None
2-Speed
2-Speed
2-Speed
None
°C
2
None
2-Speed
2-Speed
1-Speed
None
°C
3
None
2-Speed
2-Speed
None
1-Speed
°C
4
None
2-Speed
2-Speed
None
None
°C
5
None
2-Speed
1-Speed
1-Speed
1-Speed
°C
6
None
2-Speed
1-Speed
1-Speed
None
°C
7
Programmable Filtration + Polling
2-Speed
2-Speed
2-Speed
None
°C
8
Programmable Filtration + Polling
2-Speed
2-Speed
1-Speed
None
°C
9
Programmable Filtration + Polling
2-Speed
2-Speed
None
1-Speed
°C
10
Programmable Filtration + Polling
2-Speed
2-Speed
None
None
°C
11
Programmable Filtration + Polling
2-Speed
1-Speed
1-Speed
1-Speed
°C
12
Programmable Filtration + Polling
1-Speed
1-Speed
1-Speed
1-Speed
°C
13
Programmable Filtration + Polling
2-Speed
1-Speed
1-Speed
None
°C
14
Programmable Filtration + Polling
1-Speed
1-Speed
1-Speed
None
°C
15
None
2-Speed
2-Speed
1-Speed
1-Speed
°C
16
Programmable Filtration + Polling
2-Speed
2-Speed
1-Speed
1-Speed
°C
17
Programmable Filtration + Polling
1-Speed
1-Speed
None
1-Speed
°C
18
None
2-Speed
1-Speed
None
1-Speed
°C
Color
System (and any replacement board)
is shipped in Setup 1
Output
Key
XP332
XP332 and Splitter
XP332 and Splitter and in-line Blower fuse
J14 (Aux) on Main Board
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
7
56389-02/56390-02/56391-02/56587_97_E
08-06-14
Changing Software Setups with TP800 / TP900 / spaTouch™ Menued Panel
Test Menu Access (S1, Switch 1 ON) Service Technician ONLY.
1
DANGER! HIGH VOLTAGE WILL BE ACCESSIBLE! SERVICE TECHNICIAN ONLY!
While the system is running, move DIP Switch 1 (on S1 on the Main circuit board) to ON.
The system will enter Test Mode.
Moving DIP Switch 1 to OFF will exit Test Mode.
Software Setups
Under the TEST Menu, the Setup screen will allow changing the
Setup from 1 to any number established by the Manufacturer.
Changing the Setup may require wiring changes as well.
10
ON
S1
102°F
High Range
Set: 104°F
8:32 PM
Ozone
Filter 1
Spa
Shortcuts
Settings
Test
Test
Ready in Rest Mode
Heating
Back
Note: The Timeouts and Temp Limit
selections should NEVER be changed.
They are for safety agency testing
purposes only.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
8
56389-02/56390-02/56391-02/56587_97_E
`
08-06-14
Setup
A/B Temps
Fault Log
Timeouts
Temp Limit
1 `
Off
`
Normal
Yes
BP2500 Sheet
Changing
Software Setups with TP600/400
Customer
Test
Menu Access (S1, Switch 1 ON) Service Technician ONLY.
Part Number:
DANGER!
HIGH VOLTAGE WILL
__________________
BE ACCESSIBLE! SERVICE TECHNICIAN ONLY!
While the
Custom
Box
system
Overlay
is running, move DIP Switch 1 (on S1 on the Main circuit board) to ON.
The system will enter Test Mode.
Moving DIP Switch 1 to OFF will exit Test Mode.
As soon as Switch #1 is placed
in the ON position, the temperature will show
“T” after it instead of F or C, indicating the
System is in Test Mode
Software Setups
Under the TEST Menu, the Setup screen will allow changing the Setup from 1 to any number established by the Manufacturer.
Changing the Setup may require wiring changes as well.
You will have 1 minute to complete the setup change after you manually exit Priming Mode. (Once familiar with the process,
the Setup change should take less than 15 seconds.)
When the panel displays RUN PMPS PURG AIR, press any Temperature button ONCE to exit Priming Mode.
You should see “---T” where the T indicates the system is in Test Mode.
READY
RANGE
Continued on Next Page.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
9
56389-02/56390-02/56391-02/56587_97_E
08-06-14
1
ON
6
S1
BP2500 Sheet
Changing
Software Setups with TP600/400 Continued
Again,
You will have 1 minute to complete the setup change after you manually exit Priming Mode.
Customer
Immediately after exiting Priming Mode, press this sequence of buttons: Warm*, Light, Warm, Warm, Warm, Warm. Continue to press Warm until the diplay
Part Number:
__________________
shows the Setup Number (S-01, S-02, etc.) you want to switch to. When the correct setup number is showing, press Light once, and the system will reset,
Custom
Box
Overlay
using the
newly-selected
Setup from that point on.
THIS SYSTEM IS
CONFIGURED AS
SETUP #
Move DIP Switch 1 to the OFF position to take the spa out of Test Mode. °F or °C will replace °T.
Using a permanent marker, write the Setup number on the Setup label mounted inside the system lid (right). This is very important to any service
person in the future who may need to replace a circuit board or system and needs to change the Setup on a replacement part while in the field.
NOTE: Changing the Setup may require wiring changes as well - refer to the wiring diagram or wiring diagram addendum.
Main Screen
READY
RANGE FLTR1
SET
RANGE
Key
The System will reset and go into Priming Mode if the Light Button
is pressed while anything other than the current setup is flashing.
If there is no change to the Setup Number (S-01, S-02, etc.),
the display returns to the SETP screen.
While the Set Temperature is
still flashing, press Light
TEST will now appear in
the LCD first.
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message - every 1/2 second
A temperature button, used for “Action”
Light or dedicated “Choose” button, depending on control panel configuration
Waiting time - varies depending on function
SET
SET
SET
Several Setups can
exist in in this string
A dash (--) indicates the current Setup.
SET
When set to ON, Panel will display
alternate readings from
Senor A and Sensor B
on Main Screen
SET
Displays Fault Log
or
SET
SET
SET
SET
Approx.
5 sec.
SET
or
SET
SET
Approx.
5 sec.
SET
SET
Main Screen
READY
RANGE FLTR1
*If the Control Panel does not have a Warm (Up) button, but
rather a single Temp button, use the Temp button in place
of the Warm button in the instruction above. (The flow chart
assumes a single Temperature Button.)
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
10
56389-02/56390-02/56391-02/56587_97_E
08-06-14
Equipment Expansion
Expansion Features
Control Connection
Default
Fuse
Relay 1 (J101)
Undefined
None
Relay 7/8 (J107)
See Below
30A
2-Speed Pump 3 In Setups 1, 7
1-Speed Pump 3 (only) In Setups 2, 6, 8, 13, 14
1-Speed Pump 3 And 1-Speed Blower (With Splitter & In-Line Fuse) In Setups 15, 16
1-Speed Pump 2 And 1-Speed Pump 3 In Setups 5, 11, 12
2-Speed Pump 2 In Setups 3, 9
1-Speed Pump 2 In Setup 17, 18
Unused In Setups 4, 10
Relay 9/10 (J108)
Undefined
None
Expansion Options for Relays 1 - 6 can be set for the following functions:
Unused – 1-Speed Pump – Blower – Mist – Light (120V/240V) – Other
Fuse ratings determine the Expander Board
Expansion Options for Relays 7/8 and 9/10 can be set for the following functions:
Unused – 2-Speed Pump – Any combination of 2 devices from Relays 1 - 6 Options above (Splitter adapter wire must be used)
30A fuse required on Expander Board for each control connection
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
11
56389-02/56390-02/56391-02/56587_97_E
08-06-14
DIP Switch Functions
Fixed-fuction DIP Switches
1
A1
Test Mode (normally Off).
A2
In “ON” position, add one high-speed pump (or blower) with Heater.
A3
In “ON” position, add two high-speed pumps (or 1 HS Pump and Blower) with Heater.
A4
In “ON” position, add four high-speed pumps (or 3 HS Pumps and Blower) with Heater.
A5
In “ON” position, enables Special Amperage Rule B. See Special Features section under Configuration Options for functionality with your system.
In “OFF” position, enables Special Amperage Rule A.
A6
Persistent memory reset (Used when the spa is powering up to restore factory settings as determined by software configuration).
10
ON
S1
A2, A3, and A4 work in combination to determine the number of high-speed devices and blowers that can run before the heat is disabled. i.e. A2 and A3 in the ON position
and A4 in the OFF position will allow the heater to operate with up to 3 high-speed pumps (or two HS Pumps and Blower) running at the same time. Heat is disabled when the
fourth high-speed pump or blower is turned on.
Note: A2/A3/A4 all off = No heat with any high-speed pump or blower.
Assignable DIP Switches
A7
In “ON” position, enables a 5-minute cool down for some gas heaters (Cooling Time B).
In “OFF” position, enables a 1-minute cool down for electric heaters (Cooling Time A).
Undesignated switches are not assigned a function.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
12
56389-02/56390-02/56391-02/56587_97_E
08-06-14
Jumper Definitions
J109
Non Applicable on CE models
J91
Real Time Clock Enable/Disable
Note:
J109
J91
This Jumper should NOT be shorted when the Control Panel can display time of day.
J30
Do Not Use
J31
Jumper on 1 pin with 2.0kW or smaller heater
J31
Jumper on 2 pins with a 3.0kW or higher heater
J29
Heater Disable Switch Connection. If J29 is shorted by any means, the heater will not run until J29 is no longer shorted.
J29
If J29 is shorted during power-up “J29” will appear on the panel.
The message can be dismissed with a button press, and is the only control panel notification of J29 being shorted.
No message is displayed if J29 is shorted after power-up, but the heater will not run until J29 is no longer shorted.
J29 expects a switch closure (not a voltage) as the command signal.
In some areas, a local power company may offer discounts based on voluntary “power shedding” devices that may be installed in conjunction with the spa.
J25, J26, J27
Heater Type Settings.
Note:
J24
J27
Factory Configured do not change.
J25
Jumper on center two pins (230V) when heater is running at 240V.
Two Jumpers installed; one on left 2 pins and one on right 2 pins (115V) when heater is running at 120V.
Warning!
Setting DIP switches or jumpers incorrectly may cause abnormal system behavior and/or damage to system components.
Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
Contact Balboa if you require additional configuration pages added to this tech sheet.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
13
56389-02/56390-02/56391-02/56587_97_E
08-06-14
J24
J26
230V
115V
115V
BP2100 Configuration Options
General Features
Feature
Default
Options
Pump 1 in Filter Cycle (Circ Only)
No
Yes, No
Pump 1 Low Timer
15 Minutes
Between 5 and 240 minutes
1 Minute
General Pump Timer
15 Minutes
Between 5 and 60 minutes
1 Minute
Blower Timer
15 Minutes
Between 5 and 60 minutes
1 Minute
Mister Timer
15 Minutes
Between 5 and 60 minutes
1 Minute
Light Timer
240 Minutes
Between 5 and 240 minutes
1 Minute
Circ (when enabled)
Programmable + Polling See Circ Pump Note
Increment
N/A
Circ Pump can be set with the following functions:
24 hr – 24 hr w/3° shutoff – Acts like P1 Low (filters, polls, etc. - Requires a single-speed P1)
Cleanup Cycle
30 Minutes
Between 30 and 240 minutes
- or OFF
30 Minutes
Cleaup as Preference setting
Yes
Yes, No
N/A
Ozone
With Heater Pump*
Always, Filters/Cleanup Only
N/A
Ozone Suppression
OFF
Between 30 and 120 min.
- or OFF
1 Minute
Pump Purge
60 Seconds
Between 30 and 600 seconds
5 Seconds
Blower Purge
30 Seconds
Between 5 and 300 seconds
5 Seconds
Mister Purge
5 Seconds
Purge Type
Serial - Pumps at lowest speed
* The heater Pump can be either a Circ Pump or Pump 1 Low.
Blue Indicates New Custom Configuration Default (Setup 1)
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
14
56389-02/56390-02/56391-02/56587_97_E
08-06-14
BP2100 Configuration Options
Temperature Features
Feature
Default
Temperature Display
°C
Options
Increment
°C, °F
All temperatures must be specified in °F. The system converts °F to °C dynamically. If Celsius is required for default settings, choose a desired °C value that (after rounding)
corresponds to a Fahrenheit value.
°C
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
°F
39
41
43
45
46
48
50
52
54
55
57
59
61
63
64
66
68
70
72
°C
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
°F
73
75
77
79
81
82
84
86
88
90
91
93
95
97
99 100 102 104
Hi-Range Min. Set Temp
80°F
Between 50 and 80°F
1°F
Hi-Range Max. Set Temp
104°F
Between 60 and 104°F
1°F
Hi-Range Default Temp*
100°F
Between 50 and 104°F
1°F
Lo-Range Min. Set Temp
50°F
Between 50 and 80°F
1°F
Lo-Range Max. Set Temp
99°F
Between 60 and 99°F
1°F
Lo-Range Default Temp*
70°F
Between 50 and 99°F
1°F
Freeze Threshold
44°F
Freeze Type
Rotating - Pumps at Lowest Speed
Temp Lock Type
Temp + Settings
Temp, Temp + Settings
N/A
*May be changed by end-user (if enabled)
Blue Indicates New Custom Configuration Default (Setup 1)
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
15
56389-02/56390-02/56391-02/56587_97_E
08-06-14
BP2100 Configuration Options
Time Features
Feature
Default
Options
Increment
Time Format*
24 Hour
12 Hour, 24 Hour
N/A
Filter 1 Start Hour*
20:00 (8:00 PM)
00:00 to 23:00
1 Hour
Filter 1 Duration*
2 Hours
Between 15 Min and 23:45
-or continuous
15 Minutes
Filter Cycle 2 Default*
OFF
OFF, ON
N/A
Filter 2 Start Hour*
08:00 (8:00 AM)
00:00 to 23:00
1 Hour
Filter 2 Duration*
15 Minutes
Between 15 Min and 23:45
-or Continuous, or Disabled
15 Minutes
Light Cycle
Disabled
Disabled, Enabled
N/A
Light Cycle Default*
OFF
OFF, ON
N/A
Light Cycle Start Hour*
21:00 (9:00 PM)
00:00 to 23:00
1 Hour
Light Cycle Duration*
15 Minutes
Between 15 Min and 04:00
-or or Disabled
15 Minutes
Cooling Time A
1 Minute
Cooling Time B
5 Minutes
*May be changed by end-user (if enabled)
Blue Indicates New Custom Configuration Default (Setup 1)
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
16
56389-02/56390-02/56391-02/56587_97_E
08-06-14
BP2100 Configuration Options
Reminder Features
Feature
Default
Reminders Shown*
Yes
Yes, No
N/A
Check pH
OFF
See Reminder Period Note
1 Days
Check Sanitizer
OFF
See Reminder Period Note
1 Days
Clean Filter
30 Days
Test GFCI
65 Days
See Reminder Period Note
1 Days
Drain Water
100 Days
See Reminder Period Note
1 Days
Change Cartridge
OFF
Clean Cover
OFF
See Reminder Period Note
1 Days
Treat Wood
OFF
See Reminder Period Note
1 Days
Change Filter
365 Days
Options
See Reminder Period Note
See Reminder Period Note
See Reminder Period Note
Increment
1 Days
1 Days
1 Days
Reminder Periods can be set between 7 and 180 days. In addition, 365 days can be chosen.
Each reminder can be turned OFF individually.
*May be changed by end-user (if enabled)
Blue Indicates New Custom Configuration Default (Setup 1)
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
17
56389-02/56390-02/56391-02/56587_97_E
08-06-14
BP2100 Configuration Options
Special Features
Feature
Default
Special Amperage Rule A
No Limitation
Special Amperage Rule B
2 high-speed pumps max. Blower turns off with 2 high speed pumps - in Setups 1-4, 6-10, 13, 15, 16, 18
No Limitation - in Setups 5, 11, 12, 14, 17
Drain Mode
Disabled
Disabled, Enabled
N/A
Demo Mode
Disabled
Disabled, Enabled
N/A
GFCI Trip
Not Applicable for CE Models
Automatic GFCI Test
Ozone Slaved to Heater Pump
Disabled
Yes in circ setups
No in non-circ setups
Disabled, 1-7 Days
1 Day
Yes, No
N/A
Dual Voltage Heater
Always Input Voltage
4°F Temperature Delta
N/A
Safety Suction
Disabled
Disabled, Enabled
N/A
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
18
56389-02/56390-02/56391-02/56587_97_E
08-06-14
TP600 Panel Configuration
Button Layout Table
Button
#
Pump 3 or
Pump 3 +
Blower*
No Pump 3,
Blower
No Pump 3,
No Blower
Setup 3, 9, 17, 18
Setup 4, 10
1
Setups 1, 2, 5, 6,
7, 8, 11, 12, 13,
14, 15, 16
4
2
2
1
Jets 1
Jets 1
Jets 1
2
Jets 2
Jets 2
Jets 2
3
Jets 3
Blower
Unused
4
Up
Up
Up
5
Light 1
Light 1
Light 1
6
Down
Down
Down
LED 1
Jets 1
Jets 1
Jets 1
LED 2
Jets 2
Jets 2
Jets 2
LED 3
Light 1
Light 1
Light 1
LED 4
Heat On
Heat On
Heat On
5
READY
1 2
3 4
1 2
3 4
50015-04 or later - No Overaly
50336-02 or later - Includes Overlay PN 12762
TP600 (non-CE) should not be used.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
19
6
TP600CE
See Page 21.
56389-02/56390-02/56391-02/56587_97_E
08-06-14
5
RANGE FLTR1
3
3
* When using setups in column 1, which operate both a Pump 3 AND a Blower,
Pump 3 is on the main panel (Button3) and Blower must be operated with
an Auxilliary Panel - AX10A3 on Bank 1 (J5).
Template 56377 10-05-12
4
1
6
TP800 Panel Configuration
Button Layout Table
Feature
#
Pump 3,
Blower & Circ
NO Pump 3,
Blower & Circ
Pump 3,
NO Blower & Circ
NO Pump 3,
NO Blower & Circ
Pump 3,
Blower & NO Circ
NO Pump 3,
Blower & NO Circ
Pump 3,
NO Bl & NO Circ
NO Pump 3,
NO Bl & NO Circ
Setups 11, 12, 16
Setups 9, 17
Setups 7, 8,
13, 14
Setup 10
Setups 5, 15
Setup 3
Setups 1, 2, 6
Setup 4
A1
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
A2
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
A3
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
A4
Jets 3
Blower
Jets 3
Light 1
Jets 3
Blower
Jets 3
Light 1
A5
Blower
Light 1
Light 1
Invert
Blower
Light 1
Light 1
Invert
A6
Light 1
Invert
Invert
(Circ Icon)
Light 1
Invert
Invert
Undefined
A7
Invert
(Circ Icon)
(Circ Icon)
Undefined
Invert
Undefined
Undefined
Undefined
A8
(Circ Icon)
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
A9
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
A10
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
A11
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
A12
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
A13
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
A14
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
A15
Blower
Blower
Jets 3
Light
Blower
Blower
Jets 3
Light
A16
Light
Light
Light
Invert
Light
Light
Light
Invert
B1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
B2
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
B3
Jets 3
Blower
Jets 3
Undefined
Jets 3
Blower
Jets 3
Undefined
B4
Light 1
Light 1
Light 1
Light 1
Light 1
Light 1
Light 1
Light 1
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
20
56389-02/56390-02/56391-02/56587_97_E
08-06-14
TP800 Panel Configuration
Spa Screen
B1
A6
B2
A2
A3
A4
A5
A7
A8
A9
A10
B3
B4
Shortcuts Screen
A13
B1
A13
A14
B2
B3
A15
A16
B4
A14
A15
A16
Note: Buttons 11 and 12 are
not used in this configuration.
Button 1 is fixed.
A Circ Icon will appear when a Circ Pump is configured.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
21
56389-02/56390-02/56391-02/56587_97_E
08-06-14
TP900 Panel Configuration
Button Layout Table
Button
#
Pump 3,
Blower & Circ
NO Pump 3,
Blower & Circ
Pump 3,
NO Blower & Circ
NO Pump 3,
NO Blower & Circ
Pump 3,
Blower & NO Circ
NO Pump 3,
Blower & NO Circ
Pump 3,
NO Bl & NO Circ
NO Pump 3,
NO Bl & NO Circ
Setups 11, 12, 16
Setups 9, 17
Setups 7, 8,
13, 14
Setup 10
Setups 5, 15
Setup 3
Setups 1, 2, 6
Setup 4
1
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
2
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
3
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
4
Jets 3
Blower
Jets 3
Light 1
Jets 3
Blower
Jets 3
Light 1
5
Blower
Light 1
Light 1
Invert
Blower
Light 1
Light 1
Invert
6
Light 1
Invert
Invert
(Circ Icon)
Light 1
Invert
Invert
Undefined
7
Invert
(Circ Icon)
(Circ Icon)
Undefined
Invert
Undefined
Undefined
Undefined
8
(Circ Icon)
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
9
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
10
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
11
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
12
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
13
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
14
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
Jets 2
15
Jets 3
Blower
Jets 3
Light
Jets 3
Blower
Jets 3
Light
16
Light
Light
Light
Invert
Light
Light
Light
Invert
A Circ Icon will appear when a Circ Pump is configured.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
22
56389-02/56390-02/56391-02/56587_97_E
08-06-14
TP900 Panel Configuration
Spa Screen
Button
#
1
2
3
4
5
7
8
9
10
2
6
3
4
5
6
7
8
9
Shortcuts Screen
13
10
11
13
12
14
13
14
15
16
14
15
15
16
16
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
23
56389-02/56390-02/56391-02/56587_97_E
08-06-14
BP2100 Configuration Options
Auxiliary Panel Features on Bank 1*
Feature
Default
Options
Increment
Aux Button A1
Jets 1
See Aux Button Note
N/A
Aux Button A2
Jets 2
See Aux Button Note
N/A
Aux Button A3
Blower
See Aux Button Note
N/A
Aux Button A4
Light
See Aux Button Note
N/A
Auxiliary Panel Features on Bank 2*
Feature
Default
Options
Increment
Aux Button A5
Jets 1
See Aux Button Note
N/A
Aux Button A6
Jets 2
See Aux Button Note
N/A
Aux Button A7
Jets 3
See Aux Button Note
N/A
Aux Button A8
Light
See Aux Button Note
N/A
Aux Buttons can be set with the following functions:
Unused – Up – Down – Temp – Jets 1 – Jets 2 – Jets 3 – Jets 4 – Jets 5 – Jets 6 – Jets 7 – Jets 8 – Blower 1 – Blower 2 –
Mister 1 – Mister 2 – Mister 3 – Light 1 – Light 2 – Light 3 – Light 4 –
Fiber Optic – Option 1 – Option 2 – Option 3 – Option 4 – EitherLight
*Bank 1 consists of J5 on the Main Circuit Board.
Bank 2 consists of J8 on the Main Circuit Board.
Aux Connection Splitter PN25257 may be required.
Buttons that are assigned to equipment that is
not defined in a Setup will not do anything in that Setup.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
24
56389-02/56390-02/56391-02/56587_97_E
08-06-14
BP2100 Configuration Options
Auxiliary Panel Features
AX10 Panels on Bank 1*
A1, AX10A1
No O/L
52803
A2, AX10A2
No O/L
52804
A3, AX10A3
No O/L
55805 A4, AX10A4
No O/L
52806
Call Customer Service for
additional information about Auxiliary Panels.
Blower
Jets 1
AX10 Panels on Bank 2*
A5, AX10A1
No O/L
52803
A6, AX10A2
No O/L
52804
A7, AX10A3
No O/L
52805
A8, AX10A4
No O/L
52806
AX20 A1A2
No O/L
52800
AX20 Auxiliary Panel plugged into Bank 1 will operate A1 + A2, A3 or A4.
AX20 A1A3
No O/L
52801
AX20 Auxiliary Panel plugged into Bank 2 will operate A5 + A6, A7 or A8.
AX20 A1A4
No O/L
52802
*Bank 1 consists of J5 on the Main Circuit Board.
Bank 2 consists of J8 on the Main Circuit Board.
Aux Connection Splitter PN25257 may be required.
AX20
A2, 3 or 4
A1
AX40
AX40
AX40 Auxiliary Panel plugged into Bank 1 will operate A1 + A2, A3 and A4.
No O/L
52799
AX40 Auxiliary Panel plugged into Bank 2 will operate A5 + A6, A7 and A8.
A1
A2
A3
A4
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
25
56389-02/56390-02/56391-02/56587_97_E
08-06-14
BP2100 Configuration Options
Remote Panel Features
Feature
Default
Options
Increment
Remote Button A1
Jets 1
See Remote Button Note
N/A
Remote Button A2
Jets 2
See Remote Button Note
N/A
Remote Button A3
Jets 3
See Remote Button Note
N/A
Remote Button A4
Blower
See Remote Button Note
N/A
Remote Button A5
Light
See Remote Button Note
N/A
Remote Button A6
Undefined
See Remote Button Note
N/A
Remote Button A7
Undefined
See Remote Button Note
N/A
Remote Button A8
Undefined
See Remote Button Note
N/A
1
2
4
5
Remote Buttons can be set with the following functions:
Unused – Up – Down – Temp – Jets 1 – Jets 2 – Jets 3 – Jets 4 – Jets 5 – Jets 6 – Jets 7 – Jets 8 – Blower 1 – Blower 2 –
Mister 1 – Mister 2 – Mister 3 – Light 1 – Light 2 – Light 3 – Light 4 –
Fiber Optic – Option 1 – Option 2 – Option 3 – Option 4 – EitherLight
4 5
1 2 3
6 7 8
Buttons that are assigned to equipment that is
not defined in a Setup will not do anything in that Setup.
Remote Panel Part Number
_____________________
Overlay Part Number
_____________________
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2012 Balboa Water Group.
Template 56377 10-05-12
26
56389-02/56390-02/56391-02/56587_97_E