Danfoss | DHP-S Eco | Wiring Diagram DHP-S Eco, 400V 3N

MAKING MODERN LIVING POSSIBLE
Wiring Diagram
DHP-S Eco, 400V 3N
www.heating.danfoss.com
Danfoss A/S is not liable or bound by warranty if these
instructions are not adhered to during installation or service.
The English language is used for the original instructions.
Other languages are a translation of the original instructions.
(Directive 2006/42/EC)
© Copyright Danfoss A/S
Wiring Diagram
DHP-S Eco, 400V 3N
Table of Contents
1
Legend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1 Legend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
4
2
DHP-S Eco 400V 3N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1 DHP-S Eco 22 - 42kW 400V 3N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
6
Danfoss Heating Solutions
VWIFR102
3
Wiring Diagram
1
Legend
1.1
Legend
Number/Note
1
3
36
40
50
51
52
4
DHP-S Eco, 400V 3N
53
55
62
69
71
Description
Heat pump
Outdoor unit
Circulation pump (system)
Expansion card
Outdoor sensor
System supply line sensor
Sensor for EM-Modul module/ret.line sensor
Hot water starting sensor
Hot water sensor top
Room Sensor
Shunted loop
Flow guard
115
117
Immersion heater
Additional heater
301
302
303
304
305
306
307
308
309
310
311
312
313
317
Compressor
Brine pump
Radiator pump
Circulation pump
Fan
System circulation pump
Distribution circulation pump
Condenser pump
Hot gas pump
Reversing valve
4 way valve
Bypass valve
Electronic expansion valve
Immersion heater
340
341
342
343
344
345
350
351
353
354
355
362
Temperature guard
Thermal overload relay
Circuit breaker
Line circuit breaker
Alarm relay
Contactor
Soft start
Capacitor
Drip tray heater
Compressor Heater
Drip tray heater cable
Shunt valve control
VWIFR102
Number/Note
363
364
365
366
367
368
369
370
371
372
373
374
375
376
Description
Reversing valve hot-water
Shunt valve hot-water
Supply line sensor
Return line sensor
System shunt
Distribution circuit shunt
Pool heating valve
2nd distribution circuit pump
Auxiliary heating Oil/El
Auxiliary top heating
Distribution circuit shunt 2
Shunt defroster
Brine valve
Shunt cooling
403
405
406
407
408
410
Operating pressure switch
Heating out sensor
Room sensor
HGW sensor
EVU
Hot water
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
Heating return sensor
Brine out sensor
Brine in sensor
High pressure switch
Low pressure switch
Discharge pipe sensor
Defrost sensor
Refrigerant 1 sensor
Refrigerant 2 sensor
Pressure transmitter
Suction gas sensor
Dewpoint sensor
Sensor pool
Sensor cooling
Sensor buffer tank
Sensor system supply line
Sensor distribution circuit 1
Sensor distribution circuit 2
451
452
453
Control unit
I/O controller
Display
Danfoss Heating Solutions
Wiring Diagram
DHP-S Eco, 400V 3N
Number/Note
454
455
456
457
458
459
460
461
Description
Electronic expansion valve controller
Indoor hub controller
Current limiter
WM-HPC Control module
HPC-RM Relay module
HPC-EM Expansion module
HPC-CM Cooling module
HPC-OP Operator panel
* Note 1
* Note 2
* Note 2
* Note 2
* Note 2
* Note 2
* Note 2
* Note 2
* Note 2
* Note 2
* Note 2
* Note 3
Strapped at delivery
blue
brown
grey
green
yellow
violet
pink
red
black
white
Can be connected to 230V single phase if
auxiliary heater is disconnected.
When connected to 230V single phase
straps to auxiliary heater shall be removed.
Remove jumper when using separate supply of control circuit
* Note 4
* Note 5
Danfoss Heating Solutions
Number/Note
* Note 6
* Note 7
* Note 8
* Note 9
* Note 10
* Note 11
* Note 12
* Note 13
* Note 14
* Note 15
* Note 16
* Note 17
* Note 18
* Note 19
* Note 20
* Note 21
* Note 22
* Note 23
* Note 24
* Note 25
* Note 26
* Note 27
VWIFR102
Description
Remove jumper when using flowguard
Overload relay trip/tripped out
Alarm
Speed control
Please make sure that all supply lines are
disconnected before attending any work
to internal electrical parts!
Fan overload relay
To indoor unit
To slave unit
To electronic expansion unit
Immersion heater or external auxiliary
heater
Potential free contact
To outdoor unit
To expansion Unit
Communication
Passive cooling Brine circuit
Passive cooling Radiator circuit
Combined heat source system
Passive cooling
Remove jumper when EVU
EVU constant power supply
Remove jumper if EVU is supplied separately
Remove jumper when flowguard or pressure switch Brine is used
5
Wiring Diagram
6
2
DHP-S Eco 400V 3N
2.1
DHP-S Eco 22 - 42kW 400V 3N
DHP-S Eco, 400V 3N
VWIFR102
Danfoss Heating Solutions
Wiring Diagram
Danfoss Heating Solutions
DHP-S Eco, 400V 3N
VWIFR102
7
Wiring Diagram
8
DHP-S Eco, 400V 3N
VWIFR102
Danfoss Heating Solutions
Wiring Diagram
Danfoss Heating Solutions
DHP-S Eco, 400V 3N
VWIFR102
9
Wiring Diagram
10
DHP-S Eco, 400V 3N
VWIFR102
Danfoss Heating Solutions
Wiring Diagram
Danfoss Heating Solutions
DHP-S Eco, 400V 3N
VWIFR102
11
Wiring Diagram
DHP-S Eco, 400V 3N
Danfoss Heat Pumps
Box 950
671 29 ARVIKA
Phone +46 570 81300
E-mail: dhpinfo@danfoss.com
Internet: www.heating.danfoss.com
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective
companies. Danfoss Heating Solutions and the Danfoss Heating Solutions logotype are trademarks of Danfoss A/S. All rights reserved.
VWIFR102
Produced by Danfoss Heating Solutions © 2013
Download PDF