Sharp | AN-PH20EZ | XG-PH50X Optional Lens Installation Guide

Installation Manual
WARNING: This installation manual is for use by
service personnel. Please be aware that the
manufacturer cannot be responsible for breakage
or damage incurred due to improper installation of
this lens or use of the projector.
When replacing the lens, please have the lens replaced by
the store of purchase or a Sharp Engineering certified
service workshop. The inside of the projector contains highvoltage parts that can be extremely dangerous. Never
attempt to replace the lens by yourself.
AN-PH10EX
AN-PH20EZ
AN-PH30EZ
AN-PH40EZ
AN-PH50EZ
AN-PH60EZ
Always make sure to turn off the main power and unplug
the power cord before replacing the lens.
Be careful not to allow any screws to drop inside the projector
while working. This can cause a fire, electrical shock or
malfunction.
Do not attempt to replace the lens while the projector is
suspended from the ceiling. The lens may fall out of the projector
resulting in injury.
1
2
Loosen the lamp replacement
screw (1
1) that fastens the lamp
unit cover, and remove the lamp
unit cover by sliding in the direction shown by the arrow (2
2).
Remove the mounting screws of
the top cover.
Lamp replacement
screw
Lamp unit cover
Top cover
2
Before replacing the lens, return the lens shift to the position
shown below. (The lens shift is adjusted to the position shown
below when shipped from the factory.)
• V (vertical) shift: Uppermost position
• H (horizontal) shift: Middle position
1
When replacing the lens, use a commercially available
screwdriver that satisfies all of the conditions indicated below.
• Type 2 Philips head screwdriver
• Length of protruding section: min. 180 mm (10")
• Magnetized
Mounting screws
3
4
5
6
1)
Unplug the cable connector (1
2).
and remove the top cover (2
Release the tabs while pulling up
on the lens cover, and then pull
it out towards you.
(When the lens being removed is the ANPH30EZ (XG-PH50X standard lens))
Unplug the cable connector.
1
Cable
connector
2
Remove the lens ring by turning
in the direction shown by the arrow.
Cable connector
Tabs
Lens cover
7
8
9
10
Remove the lens mounting
screws.
Pull out the lens towards you and
2) by rothen take out the lens (2
tating it 90 degrees (1
1) in the direction shown by the arrow.
Remove the lens cap (on the
back) from the replacement lens.
Insert the replacement lens into
the lens mount with the motor
section facing up.
• This explanation uses the example of the
AN-PH10EX.
Lens mount
Positioning pin
Lens mounting screws
Motor section
1
Lens cap (back)
2
11
12
13
14
Rotate the replacement lens 90
degrees in the direction shown
1), align the posiby the arrow (1
tioning pin with the guide hole
2), tighten the lens mounting
(2
screws and then connect the
3).
cable connector (3
(When the lens being attached is the ANPH30EZ (XG-PH50X standard lens))
Attach the lens cover.
Connect the cable connector by
following steps 1 through 3, and
then attach the top cover and
lamp unit cover.
3 Cable connector
Attach the lens ring.
• Align the a mark on the lens ring with the
positioning pin on the lens (silver pin), insert the lens ring all the way to the back
and then rotate in the direction of the arrow.
• Insert the lens cover while spreading apart
the ring section (made of rubber), and then
attach the tabs to the ribs.
• The power of the projector will not come
on unless the lamp unit cover is securely
attached.
Positioning pin
Ribs
Guide
hole
1
Tabs
Positioning pin
2
a mark
Lens cover
Printed in China
TINS-B760WJZZ
05P01-CH-NM