58CVA/CVX
INFINITY™ 80 VARIABLE SPEED
4-WAY MULTIPOISE FURNACE
Input Capacities: 70,000 thru 155,000 Btuh
Product Data
THE INFINITY® 80 GAS
FURNACE
ISO 9001:2000
The Infinity™ 80 Variable-Speed, 4-way Multipoise
Gas Furnaces offer unmatched comfort with ComfortHeat™ technology and IdealHumidity™ in an
80% AFUE gas furnace. You get all the benefits of a
ComfortHeat technology furnace: reduced drafts,
reduced sound levels, longer cycles, less temperature
swings between cycles, and less temperature differences between rooms. With the variable speed blower
motor, homeowners can now economically run constant fan to help eliminate temperature differences
throughout the house and to get better indoor air quality. This IdealHumidity furnace also increases comfort
in the summer by wringing out extra humidity when
needed. The Infinity 80 furnaces are approved for use
with natural or propane gas, and the 58CVX is also
approved for use in Low NOx Air Quality Management Districts.
Carrier Infinity™ System When the Infinity 80 variable-speed gas furnace is matched with the Infinity
Control and an air conditioner or heat pump, you will
experience the ultimate in ComfortHeat and Ideal
Humidity through unparalleled control of temperature,
humidity, indoor air quality, and zoning. The Carrier
Infinity System also provides unprecedented ease of
use through on-screen, text-based service reminders
and equipment malfunction alerts.
For even greater comfort and convenience, match the
Infinity 80 furnace with an Infinity air conditioner or
heat pump. This will create a fully communicating system, requiring only 4 thermostat wires between system
components, and troubleshooting can even be done in
the future from the outdoor unit without entering the
home.
REGISTERED
Optional remote access through telephone or Internet is
also available when combined with a remote connectivity kit.
INFINITY
IdealHumidity
A04042
CERTIFIED
®
MEETS DOE RESIDENTIAL CONSERVATION
SERVICES PROGRAM STANDARDS.
ama
Before purchasing this appliance, read important
energy cost and efficiency information available
from your retailer.
STANDARD FEATURES
•
•
•
Infinity™ System-match with the Infinity™ Control for Infinity™ System benefits
ComfortHeat™ Technology
Intelligent microprocessor control
Two-stage heating with single-stage thermostat
with patented Adaptive Control Technology
•
•
58CVA/CVX
Very low operating sound through
low-stage operation and QuieTech™
system
QuieTech™ system noise reduction
system
Integral part of the IdealHumidity™
System
Maximum dehumidification selection for summer time cooling
Full IdealHumidity benefits including “Super Dehumidify”
SmartEvap™–Humidity control
when using a Thermidistat/Infinity
control
Variable-speed blower motor
Super-low electrical use, up to 80
percent less than standard models
Increased SEER ratings for AC and
HP systems
Perfectly matches CFM to cooling
system at all static points
Comfort Fan™–Up to 12 cooling airflow selections from thermostat with
a wide range of capability
High-Efficiency Media Filtration
Cabinet included
Microprocessor based control center
LED diagnostics and self test feature
Stores fault codes during power outages
Adjustable heating air temperature
rise
Adjustable cooling airflow
Dehumidification selection for summer-time cooling
4-way Multipoise furnace, 13 vent
applications
Compact design - only 33-1/3 in. tall
•
•
•
•
•
•
•
•
•
•
•
•
Power Heat™ Igniter
Draft Safeguard switch to ensure
proper furnace venting
Insulated blower compartment
Inner door for tighter sealing
Hybrid Heat™ compatible
All models are chimney friendly
when used with accessory vent kit
Residential installations eligible for
consumer financing through the Retail Credit Program
LIMITED WARRANTY
•
•
20-year warranty on “Super S™”
heat exchanger
5-year parts warranty on all other
components
BLOWER OFF-DELAY
DHUM
120 180
90 150
Y1
G
PLT
COM W/W1 Y/Y2
24V
TEST/TWIN
R
HUM
0.5 AMP@24VAC
NUETRAL BLW
STATUS CODE LED
FUSE 3-AMP
SEC-2 SEC-1
EA C-2
L2
PLT
1
COOL
FAN
SPARE-1 SPARE-2
1-AMP@
EAC-1 115V AC PR-1
L1
HEAT
A02169
PL2
1
A02215
A02169
HEAT EXCHANGER
CONTROL BOARD
A02170
INDUCER BLOWER
Model number nomenclature
58CVA
58CVA Variable Speed 4-Way Multipoise
58CVX Low NOx version
Input Capacity
070 — 66,000 Btuh
090 — 88,000 Btuh
110 — 110,000 Btuh
2
135 — 132,000 Btuh
155 — 154,000 Btuh
070
100
12
Nominal Cooling Size
(Airflow at .5 ESP.)
(400 CFM per 12,000 Btuh)
12 — 1200 CFM
20 — 2000 CFM
22 — 2200 CFM
Series Number
Furnace Components
INDUCER MOROR
ASSEMBLY
VENT ELBOW
MAIN LIMIT SWITCH
(BEHIND GAS VALVE)
58CVA/CVX
PRESSURE
SWITCHES
DRAFT
SAFEGUARD
SWITHCH
FLUE
COLLECTOR
BOX
GAS MANIFOLD
GAS VALVE
GAS BURNER
FLAME SENSOR
MANUAL RESET
LIMIT SWITCHES
BLOWER DOOR
SAFETY SWITCH
HOT SURFACE
IGNITER
BLOWER AND
MOTOR
CONTROL
RATING PLATE
NOT SHOWN
(LOCATED ON
BLOWER DOOR)
A04137
*Elbow may be turned to a different position, depending
on type of installation
NOTE: The 58CVA/CVX Furnaces are factory shipped for use with natural gas. These furnaces can be field-converted for
propane gas with a factory-authorized and listed accessory conversion kit.
3
Carrier accessories
Electronic
ON
High Efficiency
Air Filtration System
OFF
Input Power
Cell Energized
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
DEC
NGd
NI
Hazar
AR
WSh
ock
l
pane
rly
any
vingpresent ed regula
e
damag
e remo be dirt remov
fire
r befor ly may edover or
supp collect
te powe r ntly and in flash
powe
result
remo
freque
one
may
n OFFthan inpected that
Tur
More be ulation
shouldaccum
ent ve
equipm
t excessi
Thispreven
to
! ic
ctr
Ele
58CVA/CVX
A03149
CONTROLS:
THERMOSTATS
AND ZONING
Available in programmable and nonprogrammable models, Carrier thermostats maintain a constant, comfortable
temperature level in the home.
For the ultimate in home comfort, Carrier’s
2, 4, and 8-zone systems allow temperature control of individual “zones” of the
home. This is accomplished through a
series of electronic dampers and remote
room sensors. Infinity™ Control shown.
A01484
C04008
MECHANICAL
OR ELECTRONIC
AIR CLEANER
MODEL HUMCCLFP
HUMIDIFIER
By adding moisture to winter-dry
air, a Carrier humidifier can often
improve comfort and keep
furniture, rugs, and draperies in
better condition. Moisturizing
household air also helps to retain
normal body heat and provides
comfort at lower temperatures.
Cleans the air of smoke, dirt, and
many pollens commonly found.
Saves decorating and cleaning
expenses by keeping carpets,
furniture, and drapes cleaner.
Electronic air cleaner is shown.
Accessories
ELECTRONIC AIR CLEANER (EAC)
MECHANICAL AIR CLEANER
Model EACA
Models EZXCAB, FILCAB
HUMIDIFIER
Model HUM
HEAT RECOVERY VENTILATOR
Model HRV
ENERGY RECOVERY VENTILATOR
Model ERV
Auto Changeover, °F/°C, 1-Stage Heat/1-Stage Cool - TSTATCCNAC01-B
Auto Changeover, °F/°C, 2-Stage Heat/1-Stage Cool - TSTATCCNHP01-B
THERMOSTAT–NON-PROGRAMMABLE
Auto Changeover, °F/°C, 2-Stage Heat/2-Stage Cool - TSTATCCN2S01-B
in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode
Air Conditioner, 1-Stage Heat/1-Stage Cool, Manual Changeover, °F/°C - TSTATCCBAC01
Auto Changeover, 7-Day Programmable, °F/°C, 1-Stage Heat/1-Stage Cool-TSTATCCPAC01-B
Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat/1-Stage Cool - TSTATCCPHP01-B
Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat/1-Stage Cool - TSTATCCP2S01-B
THERMOSTAT–PROGRAMMABLE
in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode
Dual Fuel Thermostat Includes Outdoor Air Temperature Sensor -TSTATCCPDF01-B
Thermidistat Control - Non-Programmable/Programmable Thermostat -TSTATCCPRH01-B
with Humidity Control (For use in Dual Fuel, AC, HP, and 2S applications, includes Outdoor Air
Temperature Sensor)
ZONING - 2 ZONE
ZONE CC2KIT01-B, ZONE KIT2ZCAR
ZONING - 4 ZONE
ZONECC4KIT01-B
ZONING - 8 ZONE
ZONECC8KIT01-B
Infinity ™ Control Deluxe 7-Day Programmable (Wall-mounted system control.) - SYSTXCCUID01
Inifity™ Control Deluxe Zoning 7-Day Programmable (Wall-mounted control for a
multi-zone system.) - SYSTXCCUIZ01
Infinity™ 4-Zone Damper Control Module (Wall-mounted for a 4-zone system.) - SYSTXCC4ZC02
INFINITY CONTROL
Infinity™ Smart Sensor (Optional wall control used to monitor temperature and/or fan control in
an individual zone.) - SYSTXCCSMS01
Infinity™ Remote Room Sensor (Monitors temperature in an individual zone.) - SYSTXCCRRS01
Infinity™ System Access Module (Hardware for wireless access and control via phone or internet.) - SYSTXCCSAM01
Infinity™ Network Interface Module (Connects Heat Recovery and Energy Recovery Ventilators or older
two-speed outdoor models to system.) - SYSTCCNIM01†
Decorative Back Plate for Infinity Control (Decorative wall plate.) - SYSTXXXBPU01
* When applied with Carrier’s IdealHumidity series 58MVP, 58CV(A,X) and FE Indoor Models
† Must be installed in Dual-Fuel Infinity system applications.
4
Carrier Accessories
PART NO.
FILCCCAR0016
Cartridge Media Filter
070-12
090-16
X
X
FILCCCAR0020
110-20
EZ Flex Media Filter with End Caps
X
X
Unframed Filter 1-in.
X
X
X
KGAFR0501B17
X
KGAFR0601B21
X
KGAFR0701B24
External Side Return Filter Rack
X
X
EXPXXFIL0024
External Bottom Return Filter Rack
X
X
EXPXXFIL0020
KBAFR0401B14
X
X
EXPXXUNV0024
Replacement EZ Flex Filter Media
X
X
EXPXXUNV0020
EXPXXFIL0016
155-22
X
FILCCCAR0024
EXPXXUNV0016
135-22
58CVA/CVX
DESCRIPTION
X
X
KGAFR0801SRE
X
X
X
X
X
KGAWF1306UFR
X
X
S†
S†
S†
KGAWF1406UFR
X
X
X
Flue Extension
KGAWF1506UFR
KGAFE0112UPH
X
X
X
X
X
Combustible Floor Base
KGASB0201ALL
X
X
X
X
X
Downflow Vent Guard
KGAVG0101DFG
X
X
X
X
X
Vent Extension Kit
KGAVE0101DNH
X
X
X
X
X
Chimney Adapter Kit
KGACA02014FC
X
X
X
Chimney Adapter Kit
KGACA02015FC
X
X
Natural-to-Propane Conversion Kit*
KGANP4001ALL
X
X
X
X
X
Propane-to-Natural Conversion Kit
KGAPN3301ALL
X
X
X
X
X
Label Kit
KGALB0101KIT
X
X
X
X
X
Air Leakage Kit (Qty 10)
KGBAC0110DGK
X
X
X
X
X
ECM Motor Simulator
KGASD0201FMS
X
X
X
X
X
Advanced Product Monitor
KGAFP0201APM
X
X
X
X
X
KGAHA0150N42
KGAHA0250N43
(factory supplied)
KGAHA0350N44
KGAHA0450N45
Gas Orifice Kit (Qty 50)
KGAHA0550N46
KGAHA1550N47
See Installation Instructions for model,
altitude, and heat value usages.
KGAHA1650N48
KGAHA0650P54
KGAHA0750P55
* Factory-authorized, field installed. Fuel conversion kits are AGA/CGA recognized.
† Suitable for side return
5
Physical data
UNIT SIZE
OUTPUT CAPACITY BTUH*
(Nonweatherized ICS) †
INPUT BTUH*
58CVA/CVX
AFUE%*
110-20
135-22
155-22
71,000
89,000
107,000
125,000
Low
35,000
47,000
59,000
70,000
82,000
58CVX Downflow/Horizontal
High
51,000
68,000
85,000
102,000
119,000
Low
35,000
47,000
59,000
70,000
82,000
All 58CVA; 58CVX Upflow
High
66,000
88,000
110,000
132,000
154,000
Low
43,500
58,000
72,500
87,000
101,500
High
63,000
84,000
105,000
126,000
147,000
Low
43,500
58,000
72,500
87,000
101,500
127
151
162
177
183
High
30-60
40-70
40-70
40-70
45-75
58CVX Downflow/Horizontal
CERTIFIED TEMP RISE RANGE (°F)
AIRFLOW CFM‡
090-16
54,000
High
SHIPPING WEIGHT (lb)
CERTIFIED EXT STATIC
PRESSURE
070-12
All 58CVA; 58CVX Upflow
Low
30-60
30-60
25-55
25-55
30-60
Heating
High
0.12
0.15
0.20
0.20
0.20
Cooling
Low
0.5
0.5
0.5
0.5
0.5
1180/735
1210/985
1475/1320
1915/1700
1970/1715
Cooling
1225
1400
2095
2100
2095
Nonweatherized ICS
80.0
80.0
80.0
80.0
80.0
6
7
Heating-High/Low
SPST
LIMIT CONTROL
Solid-State Time Operation
HEATING BLOWER CONTROL
3
BURNERS (Monoport)
4
5
1/2-in. NPT
GAS CONNECTION SIZE
White-Rodgers
GAS VALVE (Redundant) Manufacturer
Minimum Inlet Pressure (In. wc)
4.5 (Natural Gas)
Maximum Inlet Pressure (In. wc)
13.6 (Natural Gas)
Hot Surface
IGNITION DEVICE
* Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4 percent for each 1000 ft above sea level. Refer to
National Fuel Gas Code Table F4 or furnace Installation Instructions. In Canada, derate the unit 10 percent for elevations 2000 to 4500 ft above sea level.
† Capacity in accordance with U.S. Government DOE test procedures.
‡ Airflow shown is for bottom only return-air supply in comfort mode (as-shipped). For air delivery above 1800 CFM, see Air Delivery Table for other options.
A filter is required for each return-air supply.
ICS — Isolated Combustion System
Blower performance data
070-12
090-16
110-20
135-22
DIRECT-DRIVE MOTOR Hp (ECM)
UNIT SIZE
1/2
1/2
1
1
1
MOTOR FULL LOAD AMPS
7.7
7.7
12.8
12.8
12.8
300-1300
300-1300
300-1300
300-1300
300-1300
10 x 6
10 x 8
11 x 10
11 x 11
11 x 11
RPM (Nominal)
BLOWER WHEEL DIAMETER WIDTHS (In.)
ECM-Electronically Commutated Motor, Variable Speed
6
155-22
INSTALLATION
O
F R AN T
AV
FR
A V ON
T
A
NT
SE
EN R V
I
TR
ET C E
IE
N
3"MIN
BOTTOM
DESSOUS
* 0"
DE
SI
É
ÔT
C
0"
Cette fournaise à air pulsé est équipée
pour utilisation avec gaz naturel et altitudes
comprises entre 0-3,050m (0-10,000 pi).
Utiliser une trousse de conversion, fournie par
le fabricant, pour passer au gaz propane ou pour
certaines installations au gaz naturel.
Cette fournaise est prévue pour être
installée dans un bâtiment construit sur place.
Cette fournaise peut être installée sur
un plancher combustible dans une alcôve ou
dans un garde-robe en respectant le minimum
d'espace libre des matériaux combustibles, tel
qu´indiqué sur le diagramme.
Cette fournaise peut être utilisée avec un
conduit d´évacuation de Type B-1 ou connectée
au conduit ommun d 'autres appareils à gaz.
†
58CVA/CVX
TOP / PLENUM
DESSUS / CHAMBRED'AIR
MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION
DISTANCE MINIMALE EN POUCES AUX CONSTRUCTIONS COMBUSTIBLES
This forced air furnace is equipped for use with This furnace is approved for UPFLOW, DOWNFLOW, and
HORIZONTAL installations.
natural gas at altitudes 0-10,000 ft (0-3,050m).
Cette fournaise est approuvée pour l 'installation HORIZONTALE
An accessory kit, supplied by the
et la circulation d 'air VERS LE HAUT et VERS LE BAS.
manufacturer, shall be used to convert to propane
gas use or may be required for some natural gas
1"
Clearance arrows
applications.
Les fléches de dégagement
ne change pas avec
This furnace is for indoor installation in a do not change with
l 'orientation de la fournaise.
furnace
orientation.
building constructed on site.
This furnace may be installed on combustible
flooring in alcove or closet at minimum clearance
0"
0"
as indicated by the diagram from combusitble
B
material.
DE
AR AC
SI T È *
K
R
IÈ
This furnace may be used with a Type B-1 Vent
E
CÔ
RE
AC SE
and may be vented in common with other gas
RN A I
F U URN
fired appliances.
O
F
NT
24"
MIN
Ø
Clearance in inches
Dégagement (po).
Vent Clearance to combustibles:
For Single Wall vents 6 inches (6 po).
For Type B-1 vent type 1 inch (1 po).
Dégagement de l´évent avec combustibles:
Pour conduit d´évacuation à paroi simple 6 po (6 inches).
Pour conduit d´évacuation de Type B-1 1 po (1 inch).
MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION
DOWNFLOW POSITIONS:
† Installation on non-combusibible floors only.
Ø
*
For Installation on combustible flooring only when installed on special base, Part No. KGASB0201ALL,
Coil Assembly, Part No. CD5 or CK5, or Coil Casing, Part No. KCAKC.
18 inches front clearance required for alcove.
Indicates supply or return sides when furnace is in the horizontal position. Line contact only permissible
between lines formed by intersections of the Top and two Sides of the furnace jacket, and building joists,
studs or framing.
DÉGAGEMENT MINIMUM EN POUCES AVEC ÉLÉMENTS
DE CONSTRUCTION COMBUSTIBLES
POUR LA POSITION COURANT DESCENDANT:
† Pour l´installation sur plancher non combustible seulement.
Ø
*
Pour l´installation sur un plancher combustible seulement quand on utilise la base spéciale, pièce
nº KGASB0201ALL, l´ensemble serpentin, pièce nº CD5 ou CK5, ou le carter de serpentin, pièce
nº KCAKC.
Dans une alcôve, on doit maintenir un dégagement à l´avant de 18 po (450mm).
La poistion indiquée concerne le côté d´entrée ou de retour quand la fournaise est dans la
position horizontale.
Le contact n´est permis qu´entre les lignes formées par les intersections du dessus et des
deux côtés de la cherrise de la fournaise et les solives, montant sous cadre de charpente.
327590-101 REV. C
7
58CVA/CVX
SEE NOTES: 1,2,4,7,8,9
SEE NOTES: 1,2,3,4,7,8,9
SEE NOTES: 1,2,4,5,7,8,9
UPFLOW
UPFLOW
DOWNFLOW
A02058
A02061
A02059
SEE NOTES:1,2,3,4,5,7,8,9
SEE NOTES: 1,2,3,4,5,7,8,9
SEE NOTES: 1,2,4,5,6,7,8,9
DOWNFLOW
DOWNFLOW
DOWNFLOW
A02063
A02060
!" #$$%&'! () " '* "
'" ! +),-..
$ "/ (- 0 (- 1 % *0 00 2/* + / 3 3* 0 4! ..5 00 *
) 2/* + 0 1 ( )- 0 6 4! ..5 500 4
7 !
/ 500 4 4! ..5 1 00 0 6 8 / !* 4 1 3 / / **
9 / !* 4
4!!.$.) 4!!.$.( * ** : 60 0 $ -
0
* **3/
:. *
, 0 ;
0 % -
0
* **3/
$. * 2/* + * <
8
A02062
SEE NOTES: 1,2,4,5,7,8,9
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL RIGHT
58CVA/CVX
HORIZONTAL RIGHT
A02070
A02068
SEE NOTES: 1,2,4,7,8,9
HORIZONTAL RIGHT
A02069
SEE NOTES: 1,2,4,7,8,9
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL LEFT
A02064
HORIZONTAL LEFT
SEE NOTES: 1,2,4,5,7,8,9
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL LEFT
HORIZONTAL LEFT
A02065
A02067
A02066
9
AIR DELIVERY- POWER DRAW (WATTS)**
Unit
Size
070-12
Operating Mode
CFM Airflow
Setting
External Static
Pressure Range*
0.1
0.2
735
1165
525
700
875
1050
1215
1400
External Static Pressure (ESP)
0.3
0.4
0.5
0.6
0.7
0.8
AIRFLOW (CFM)
735 735 725
1175 1180 1180 1180 1180 1180
525 525 510
700 695 685
875 875 875 875 865 855
1050 1050 1050 1050 1050 1050
1225 1225 1225 1225 1225 1225
1400 1400 1400 1400 1400 1385
†† Low Heat
High Heat
†† 1-1/2 Ton Cooling
†† 2-Ton A/C Cooling
2-1/2 Ton A/C Cooling
3-Ton A/C Cooling
3-1/2 Ton A/C Cooling
Maximum
735 (615)†
1180 (1060)†
525
700
875
1050
1225
1400
0-0.50
0-1.0
0-0.50‡
0-0.50‡
0-1.0‡
0-1.0‡
0-1.0
0-1.0
735
1160
525
700
875
1050
1205
1395
845 840
1045 1035
1225 1210
1360 1310
Low Heat
High Heat
†† 1-1/2 Ton
†† 2-Ton A/C
2-1/2 Ton
3-Ton A/C
3-1/2 Ton
4-Ton A/C
Maximum
985 (825)†
1210 (1090)†
525
700
875
1050
1225
1400
1600
0-1.0
0-1.0
0-0.50‡
0-0.50‡
0-1.0‡
0-1.0‡
0-1.0
0-1.0
0-1.0
950
1190
525
690
830
1005
1205
1370
1565
970
1205
525
695
855
1025
1220
1385
1580
985
1210
525
700
875
1040
1215
1395
1585
985
1210
525
700
875
1050
1225
1400
1595
985
1210
500
690
875
1050
1225
1400
1600
850
1050
1225
1400
1480
1320 (1110)†
1475 (1330)†
700
875
1050
1225
1400
1750
2100
2200
0-1.0
0-1.0
0-0.50‡
0-0.50‡
0-0.50‡
0-1.0‡
0-1.0‡
0-1.0‡
0-1.0
0-1.0
1275
1460
700
860
1050
1185
1385
1710
2090
2200
1295
1465
700
875
1050
1195
1395
1730
2100
2200
1315
1475
700
865
1045
1215
1400
1735
2100
2200
1320
1475
685
855
1050
1225
1400
1745
2100
2190
1320
1475
660
840
1050
1225
1400
1750
2095
2185
1700 (1430)†
1915 (1725)†
700
875
1050
1225
1400
1750
2100
2200
0-1.0
0-1.0
0-0.50‡
0-0.50‡
0-0.50‡
0-1.0‡
0-1.0‡
0-1.0‡
0-1.0
0-1.0
1700
1900
700
870
1010
1155
1395
1740
2075
2180
1700
1905
700
870
1030
1180
1400
1750
2085
2195
1700
1915
700
865
1050
1200
1400
1750
2090
2200
1700
1915
700
865
1050
1210
1400
1750
2100
2200
1700
1915
665
865
1050
1220
1400
1735
2100
2200
1715 (1440)†
1970 (1775)†
700
875
1050
1225
1400
1750
2100
2200
0-1.0
0-1.0
0-0.50‡
0-0.50‡
0-0.50‡
0-1.0‡
0-1.0‡
0-1.0‡
0-1.0
0-1.0
1715
1955
700
865
1015
1160
1385
1745
2055
2175
1715
1965
700
875
1020
1185
1400
1750
2070
2190
1715
1965
700
875
1035
1215
1400
1750
2080
2200
1715
1970
700
865
1045
1225
1400
1750
2085
2200
1715
1970
680
865
1050
1225
1400
1745
2095
2200
0.9
1.0
1180 1175
090-16
58CVA/CVX
A/C Cooling
Cooling
A/C Cooling
Cooling
A/C Cooling
Cooling
985 985 985 985 980
1210 1210 1210 1210 1200
875
1050
1225
1400
1600
870
1050
1225
1400
1560
865
1050
1225
1400
1520
820
1050
1220
1380
1430
110-20***
Low Heat
High Heat
†† 2-Ton A/C
†† 2-1/2 Ton
†† 3-Ton A/C
3-1/2 Ton
4-Ton A/C
5-Ton A/C
6-Ton A/C
Maximum
Cooling
A/C Cooling
Cooling
A/C Cooling
Cooling
Cooling
Cooling
1320 1320 1320 1320 1315
1475 1475 1475 1465 1465
1225
1400
1750
2085
2175
1225
1400
1750
2065
2155
1225
1400
1750
2045
2130
1225
1400
1745
2020
2085
1225
1400
1740
1990
2015
135-22
Low Heat
High Heat
†† 2-Ton A/C
†† 2-1/2 Ton
†† 3-Ton A/C
3-1/2 Ton
4-Ton A/C
5-Ton A/C
6-Ton A/C
Maximum
Cooling
A/C Cooling
Cooling
A/C Cooling
Cooling
Cooling
Cooling
1695 1700 1695 1685 1670
1915 1915 1915 1915 1915
1225
1400
1740
2100
2200
1225
1400
1735
2090
2185
1225
1390
1730
2080
2165
1225
1375
1715
2055
2140
1225
1355
1700
2025
2095
155-22
Low Heat
High Heat
†† 2-Ton A/C
†† 2-1/2 Ton
†† 3-Ton A/C
3-1/2 Ton
4-Ton A/C
5-Ton A/C
6-Ton A/C
Maximum
Cooling
A/C Cooling
Cooling
A/C Cooling
Cooling
Cooling
Cooling
1705 1710 1705 1705 1695
1970 1970 1970 1970 1960
1225
1400
1740
2100
2200
1225
1395
1745
2100
2200
1225
1395
1745
2100
2200
1225
1380
1740
2090
2180
1225
1360
1735
2065
2160
Actual external static pressure (ESP) can be determined by using the fan laws (CFM2 proportional to ESP); such as, a system with 1180 CFM at 0.5
ESP would operate at cooling airflow of 1050 CFM at 0.4 ESP and low-heating airflow of 735 CFM at 0.19 ESP.
† Low heat CFM when low-heat rise adjustment switch (SW1-3) and comfort/efficiency adjustment switch (SW1-4) on control center are OFF.
‡ Ductwork must be sized for high-heating CFM within the operational range of ESP.
** Wattage data provided is for the circulating blower with bottom return and does not include draft inducer, accessories, or gas controls.
†† Operation within the blank areas of the chart is not recommended because high-heat operation will be above 1.0 ESP.
*** All airflows on 110 size furnace are 5 percent less on side return only installations.
*
10
AIR DELIVERY- POWER DRAW (WATTS)**
Unit
Size
070-12
Operating Mode
CFM Airflow
Setting
External Static
Pressure Range*
†† Low Heat
High Heat
†† 1-1/2 Ton Cooling
†† 2-Ton A/C Cooling
2-1/2 Ton A/C Cooling
3-Ton A/C Cooling
3-1/2 Ton A/C Cooling
Maximum
735 (615)†
1180 (1060)†
525
700
875
1050
1225
1400
0-0.50
0-1.0
0-0.50‡
0-0.50‡
0-1.0‡
0-1.0‡
0-1.0
0-1.0
84
227
48
75
123
181
254
381
100
256
63
90
145
205
289
413
External Static Pressure (ESP)
0.3
0.4
0.5
0.6
0.7
0.8
POWER DRAW (WATTS)**
119 133 148
287 318 347 381 407 435
74
86
98
108 121 135
163 183 202 221 238 257
226 253 278 302 326 350
320 355 384 416 444 472
462 490 527 556 586 607
Low Heat
High Heat
†† 1-1/2 Ton A/C Cooling
†† 2-Ton A/C Cooling
2-1/2-Ton A/C Cooling
3-Ton A/C Cooling
3-1/2 Ton A/C Cooling
4-Ton A/C Cooling
Maximum
985 (825)†
1210 (1090)†
525
700
875
1050
1225
1400
1600
0-1.0
0-1.0
0-0.50‡
0-0.50‡
0-1.0‡
0-1.0‡
0-1.0
0-1.0
0-1.0
115
187
45
61
87
127
191
267
390
144
216
61
78
110
159
223
304
434
170
245
77
96
136
185
246
342
483
197
280
93
118
159
214
283
382
526
Low Heat
High Heat
†† 2-Ton A/C
†† 2-1/2 Ton
†† 3-Ton A/C
3-1/2 Ton
4-Ton A/C
5-Ton A/C
6-Ton A/C
Maximum
1320 (1110)†
1475 (1330)†
700
875
1050
1225
1400
1750
2100
2200
0-1.0
0-1.0
0-0.50‡
0-0.50‡
0-0.50‡
0-1.0‡
0-1.0‡
0-1.0‡
0-1.0
0-1.0
188
264
65
84
126
161
228
373
663
778
237
311
86
117
159
197
270
443
732
840
277
357
113
143
190
247
316
504
803
907
332 376 419 466 507 549 589
407 453 501 547 597 633 683
135 159
171 202
220 269
288 335 373 415 465 505 545
371 415 456 503 554 589 635
555 614 670 727 779 830 888
860 922 978 1027 1069 1111 1146
958 1022 1079 1133 1168 1191 1175
Low Heat
High Heat
†† 2-Ton A/C Cooling
†† 2-1/2 Ton A/C Cooling
†† 3-Ton A/C Cooling
3-1/2-Ton A/C Cooling
4-Ton A/C Cooling
5-Ton A/C Cooling
6-Ton A/C Cooling
Maximum
1700 (1430)†
1915 (1725)†
700
875
1050
1225
1400
1750
2100
2200
0-1.0
0-1.0
0-0.50‡
0-0.50‡
0-0.50‡
0-1.0‡
0-1.0‡
0-1.0‡
0-1.0
0-1.0
321
429
61
76
103
131
201
343
573
656
371
476
83
107
135
174
250
400
631
725
430
542
107
134
174
210
283
450
705
803
469
601
128
160
208
253
330
491
762
863
509
658
149
187
240
289
376
535
827
928
Low Heat
High Heat
†† 2-Ton A/C
†† 2-1/2 Ton
†† 3-Ton A/C
3-1/2 Ton
4-Ton A/C
5-Ton A/C
6-Ton A/C
Maximum
1715 (1440)†
1970 (1775)†
700
875
1050
1225
1400
1750
2100
2200
0-1.0
0-1.0
0-0.50‡
0-0.50‡
0-0.50‡
0-1.0‡
0-1.0‡
0-1.0‡
0-1.0
0-1.0
310
442
60
73
96
121
188
322
500
592
366
493
79
97
122
166
225
367
557
673
402
547
105
128
153
201
266
422
620
746
443
604
126
154
196
244
299
466
691
811
486
655
147
178
226
277
345
498
743
885
0.1
0.2
0.9
1.0
462
485
275
371
495
616
297
392
515
608
224
314
107
138
183
242
312
424
568
251
343
279
375
306
407
334
435
359
463
207
271
349
463
608
229
301
378
495
617
254
329
412
531
623
283
356
441
558
630
304
384
469
587
625
110-20***
Cooling
A/C Cooling
Cooling
A/C Cooling
Cooling
Cooling
Cooling
135-22
562
730
608
778
666
832
706
902
757
944
336 374 423 459 511
410 453 491 533 565
584 630 681 730 779
890 943 998 1044 1091
984 1047 1087 1126 1142
155-22
Cooling
A/C Cooling
Cooling
A/C Cooling
Cooling
Cooling
Cooling
525
720
580
770
621
826
668
879
719
932
314
389
546
814
935
358 400 441 491
423 462 498 540
598 653 693 740
864 936 985 1027
994 1026 1102 1129
Actual external static pressure (ESP) can be determined by using the fan laws (CFM2 proportional to ESP); such as, a system with 1180 CFM at 0.5 ESP
would operate at cooling airflow of 1050 CFM at 0.4 ESP and low-heating airflow of 735 CFM at 0.19 ESP.
† Low heat CFM when low-heat rise adjustment switch (SW1-3) and comfort/efficiency adjustment switch (SW1-4) on control center are OFF.
‡ Ductwork must be sized for high-heating CFM within the operational range of ESP.
** Wattage data provided is for the circulating blower with bottom return and does not include draft inducer, accessories, or gas controls.
†† Operation within the blank areas of the chart is not recommended because high-heat operation will be above 1.0 ESP.
*** All airflows on 110 size furnace are 5 percent less on side return only installations.
*
11
58CVA/CVX
090-16
Dimensions
28-7/8"
26-1/8"
(VENT CONNECTION)
25-1/4"
1-9/16"
A
22-9/16"
JUNCTION BOX
LOCATION
AIRFLOW
2-9/16"
D
19"
13/16"
F
7/8" DIA
ACCESSORY
8-7/16"
1-1/2" DIA.
RIGHT HAND
GAS ENTRY
58CVA/CVX
1/2" DIA THERMOSTAT
WIRE ENTRY
1-7/16"
33-5/16"
ALTERNATE
JUNCTION BOX
LOCATION (TYP)
24-7/8"
VENT OUTLET
5 PLACES (TYP)
7/8" DIA. ACCESSORY
5-1/2"
21-5/8"
BOTTOM INLET
24"
(CASING)
14-7/8"
7/8" DIA. ACCESSORY
3-3/4"
11/16"
1-11/16"
11/16"
1/2" DIA. THERMOSTAT
WIRE ENTRY
3-15/16"
LEFT HAND GAS
ENTRY
13/16"
OUTLET
4-13/16"
E
11/16"
1-1/4"
22-1/16"
SIDE INLET
1"
A03060
NOTES:
1. Two additional 7/8-in. dia. knockouts are located in the top plate.
2. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s
recommendations for equivalent diameters.
3. Minimum return-air opening at furnace.
a. For 800 CFM-16-in. round or 14-1/2 x 12-in. rectangle.
b. For 1200 CFM-20-in. round or 14-1/2 x 19-1/3 in. rectangle.
c. For 1600 CFM-22-in. round or 14-1/2 x 22-1/16-in. rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of
single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom of single side
inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom only will ensure adequate
return air openings for airflow requirements above 1800 CFM.
58CVA/CVX
UNIT SIZE
A
CABINET
WIDTH (IN.)
D
SUPPLY
WIDTH (IN.)
E
BOTTOM
RETURN WIDTH
(IN.)
F
C.L. TOP &
BOTTOM VENT
OUTLET (IN.)
VENT
CONNECTION
SIZE (IN.)
(see notes 1 & 2)
MEDIA CABINET
SIZE (IN.)
16
070-12
14-3/16
12-9/16
12-11/16
9-5/16
4
090-16
17-1/2
15-7/8
16-1/8
11-9/16
4
16
110-20
21
19-3/8
19-1/2
13-5/16
4
20
135-22
24-1/2
22-7/8
23
15-1/16
4 (note 1)
24
155-22
24-1/2
22-7/8
23
15-1/16
4 (note 1)
24
1) 135 and 155 size furnaces require five-inch vents. Use a 4-5 in. vent adapter between furnace and vent stack.
2) See Installation Instructions for complete installation requirements.
25 "
23 "
23 3/4"
Opening with Flanges Bent
22 3/4"
22 1/2"
Opening
B Opening
A
Furnace Side
23 1/8"
Centerline Screw Slots
12
Duct Side
5 3/4"
Media/
Cabinet Size
A
B
16
17"
16"
20
21"
20"
24
25"
24"
Typical wiring schematic
FIELD 24-VOLT WIRING
FIELD 115-, 208/230-, 460-VOLT WIRING
FACTORY 24-VOLT WIRING
FACTORY 115-VOLT WIRING
NOTE 2
W
FIVE
WIRE
C
Y
R
G
1-STAGE
THERMOSTAT
TERMINALS
FIELD-SUPPLIED
FUSED DISCONNECT
THREE-WIRE
HEATINGONLY
BLK
WHT
WHT
W2
58CVA/CVX
BLK
208/230- OR
460-VOLT
THREE
PHASE
COM
208/230VOLT
SINGLE
PHASE
W/W1
GND
NOTE 1
Y/Y2
115-VOLT FIELD- JUNCTION
SUPPLIED
BOX
FUSED
CONTROL
DISCONNECT
BOX
R
GND
CONDENSING
UNIT
G
24-VOLT
TERMINAL
BLOCK
FURNACE
NOTES: 1. Connect Y/Y2-terminal as shown for proper operation.
2. Some thermostats require a "C" terminal connection as shown.
3. If any of the original wire, as supplied, must be replaced, use
same type or equivalent wire.
A95236
Electrical data
OPERATING
VOLTAGE RANGE
Minimum*
MAXIMUM
UNIT AMPS
MAXIMUM
WIRE
LENGTH (FT)‡
MAXIMUM
FUSE OR CKT
BKR AMPS†
MINIMUM
WIRE GAGE
127
104
9.0
30
15
14
127
104
9.6
29
15
14
115-60-1
127
104
15.1
29
20
12
135-22
115-60-1
127
104
14.9
30
20
12
155-20
115-60-1
127
104
15.0
29
20
12
UNIT SIZE
VOLTS-HERTZPHASE
Maximum*
070-12
115-60-1
090-14
115-60-1
110-20
* Permissible limits of the voltage range at which unit operates satisfactorily.
† Time-delay type is recommended.
‡ Length shown is as measured one way along wire path between unit and service panel for maximum 2 percent voltage drop.
13
Typical Installation
CONDENSING
UNIT
58CVA/CVX
HUMIDIFIER
ELECTRONIC
AIR CLEANER
GAS-FIRED
WATER HEATER
AIRFLOW
A02184
14
15
58CVA/CVX
Guide Specifications
Gas Furnace
58CVA/CVX
General
SYSTEM DESCRIPTION
Furnish a _________________ Variable speed gas-fired
two stage furnace for use with natural gas or propane (factory
authorized conversion kit required for propane); furnish cold
air return plenum; furnish external medial cabinet for use with
accessory media filter or standard filter.
QUALITY ASSURANCE
Unit will be designed, tested and constructed to the current ANSI Z 21.47/CSA 2.3 design standard for gas-fired
central furnaces. Unit will be 3rd party certified by CSA to
the current ANSI Z 21.47/CSA 2.3 design standard for gasfired central furnaces.
Unit will carry the CSA Blue Star® and Blue Flame®
labels.
Unit efficiency testing will be performed per the current
DOE test procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed
in the latest GAMA Consumer’s Directory of Certified Efficiency Ratings.
Unit will carry the current Federal Trade Commission Energy Guide efficiency label.
DELIVERY, STORAGE AND HANDLING
Unit shall be shipped as single package only and is stored
and handled per unit manufacturer’s recommendations.
WARRANTY (for inclusion by specifying engineer)
U.S. and Canada only. Warranty certificate available upon
request.
Products
EQUIPMENT
Components shall include: slow-opening two-stage dual
fuel gas valve to reduce ignition noise, regulate gas flow,with
electric switch gas shut-off; flame proving sensor, hot surface
igniter, dual pressure switch assembly, flame rollout switch,
ICM blower and two speed inducer assembly, 40va transformer; low-voltage (heating) (heating/cooling) thermostat.
Blower Wheel and ECM Blower Motor
Galvanized blower wheel shall be centrifugal type, statically and dynamically balanced. Blower motor of ECM type
shall be permanently lubricated with sealed ball bearings,
of________hp, and supplies delivers requested airflow CFM
as defined by signals received from EZ-SELECT airflow control when 24VAC motor inputs are provided. Blower motor
shall be direct drive and soft mounted to the blower scroll to
reduce variation transmission.
Filters
Furnace shall have reusable-type filters. Filter shall be
_______in (x) _______in. An accessory high efficiency Media Filter is available as an option.____________Media Filter.
Copyright 2006 Carrier Corp. • 7310 W. Morris St. • Indianapolis, IN 46231
Casing
Casing shall be of .030 in. thickness minimum, pre-painted
galvanized steel.
Two-Speed Inducer Motor
Two-Speed Inducer motor shall be of two-speed design
being soft mounted to assembly to reduce vibration
transmission.
Flame Rollout Switch
Flame Rollout Switch shall be factory installed near burner
area to further reduce the possibility of a stuck gas valve or
failed inducer motor.
Heat Exchangers
Primary Heat exchangers shall be 4-Pass 20 gage corrosion resistant aluminized steel of fold-and-crimp sectional design when applied operating under negative pressure.
Controls
Controls shall include a micro-processor based integrated
electronic control board with at least 11 service troubleshooting codes displayed via diagnostic flashing LED light on the
control, a self-test feature that checks all major functions of
the furnace, and a replaceable automotive-type circuit protection fuse. Multiple operational settings available with the EZSELECT fan control, including, separate blower speeds for
low heat, high heat, low cooling, high cooling and continuous
fan. Continuous fan speed may be adjusted from the thermostat. Cooling airflow will be selectable between 350 or 400
CFM per ton of air conditioning. Features will also include
temporary reduced airflow in the cooling mode for improved
dehumidification when an Infinity Control or Thermidistat®
is selected as the thermostat.
OPERATING CHARACTERISTICS
Heating Capacity shall be _________ Btuh input; _______
Btuh output capacity.
Fuel Gas Efficiency shall be 80% AFUE.
Air delivery shall be _________ cfm minimum at 0.50 in.
wg external static pressure.
Dimensions shall be: depth _________ in.;
width_________in; height __________in. (casing only).
Height shall be _________ in. with A/C coil and __________
in. overall with plenum.
ELECTRICAL REQUIREMENTS
Electrical supply shall be 115 volts, 60 Hz, single-phase
(nominal). Minimum wire size shall be ________ AWG;
maximum fuse size or HACR-type designated circuit breaker
shall be ________ Amps.
SPECIAL FEATURES
Refer to section of the product data sheet identifying accessories and descriptions for specific features and available
enhancements.
Printed in U.S.A.
Manufacturer reserves the right to change, at any time, specifications or designs without notice and obligations
edition date: 1/06
Catalog No: 58CV-4PD
Replaces: 58CV-3PD