Professional Series Dual Detectors ISC-PDL1-W18G and

Intrusion Systems Professional Series Dual Detectors ISC-PDL1-W18G and ISC-PDL1-W18H
Professional Series Dual Detectors
ISC-PDL1-W18G and ISC-PDL1-W18H
Introduction
The Professional Series Dual Detectors ISC-PDL1-W18G
and ISC-PDL-W18H are exceptionally suited for
commercial indoor applications. The self-locking twopiece enclosure, built-in two-way bubble level, flexible
mounting height, and three optional mounting brackets
simplify installation and reduce service time. Sensor
data fusion technology ensures that the detectors send
alarm conditions based on precise information.
Microwave anti-masking makes it difficult for intruders
to obscure the detectors. Tri-focus optics technology
eliminates coverage gaps and responds efficiently to
intruders. The powerful combination of unique features
in the Professional Series delivers superior catch
performance and virtually eliminates false alarms.
Functions
18 m x 25 m (60 ft x 80 ft) coverage, field selectable
to 7.5 m x 10 m (25 ft x 33 ft)
Sensor data fusion technology
2 m to 3 m (7 ft to 10 ft) mounting height, no
adjustments required
Tri-focus optics technology
Microwave anti-masking feature
Active white light suppression
Dynamic temperature compensation
Remote walk test
Alarm memory
Draft and insect immunity
Supervised Microwave and PIR
Provides single technology coverage if the microwave
subsystem fails.
Tri-focus Optics Technology
Tri-focus optics technology uses optics with three
specific focal lengths: long-range coverage, middlerange coverage, and short-range coverage. The detector
applies the three focal lengths to 86 detection zones,
which combine to make 11 solid curtains of detection.
Tri-focus optics technology also includes two
pyroelectric sensors, which deliver twice the standard
optical gain. The sensors process multiple signals to
deliver precise performance virtually free of false
alarms.
Active White Light Suppression
Sensor Data Fusion Technology
Sensor data fusion technology is a unique feature that
uses a sophisticated internal microcontroller to gather
signals from five sensors: two pyroelectric sensors, a
Doppler microwave sensor, a room temperature sensor,
and a light level sensor. The microcontroller analyzes and
compares the sensor data to make the most intelligent
alarm decisions in the security industry.
Microwave Anti-Masking
An internal light sensor measures the level of light
intensity directed at the face of the detector. Sensor
data fusion technology uses this information to eliminate
false alarms from bright light sources.
Field Selectable Coverage (18 m x 25 m or 7.5 m x
10 m)
Installers can use a DIP switch to select 18 m x 25 m or
7.5 m x 10 m (60 ft x 80 ft or 25 ft x 33 ft) coverage.
Sends a supervision trouble signal if microwave
reflective material is placed within 30.5 cm (1 ft) of
detector.
www.boschsecurity.com
2 | Professional Series Dual Detectors ISC-PDL1-W18G and ISC-PDL1-W18H
Dynamic Temperature Compensation
Trouble Memory
The detector adjusts PIR sensitivity to identify human
intruders at critical temperatures. Dynamic temperature
compensation detects human body heat accurately,
avoids false alarms, and delivers consistent catch
performance at all operating temperatures.
When the walk test input switches to its true state for
less than two seconds, LED flashes to indicate the most
recent trouble condition. If there is no trouble in
memory, the LED does not flash. After twelve hours, or
after the detector receives a second walk test pulse for
two seconds or less, the LED stops flashing and the
trouble memory clears.
Cover and Wall Tamper Switch
When an intruder removes the cover or attempts to
separate the detector from the wall, a normally-closed
contact opens to alert the control panel.
Parts Included
Quantity
Component
Self-adjusting LED
1
Detector
The LED brightness adjusts automatically to the
surrounding light level. A blue light emitting diode (LED)
indicates dual alarms and activates during a walk test. A
yellow LED indicates microwave alarms, and a red LED
indicates PIR alarms.
2
Flat-head screws
2
Screw anchors
1
Nylon cable tie
1
Pattern Mask
1
Installation Guide
Remote Walk Test LED
Users can enter a command at the control panel to
remotely enable or disable the walk test LED. Users can
locally enable or disable the walk test LED through the
DIP switch.
Certifications and Approvals
The detectors are designed to comply with the following standards and
approvals.
cULus - UL639, Intrusion Detection Units
Alarm Memory

Alarm memory flashes the alarm LED to indicate stored
alarms for use in multiple unit applications. A switched
voltage from the control panel controls the alarm
memory.
C-Tick
EN50131-1 Grade 2
FCC
IC
Solid State Relays
Solid state relays send silent alarm output signals to
provide a higher level of security and reliability. An
external magnet will not activate the relay. The solid
state relay uses less current than a mechanical relay,
providing longer standby capacity during a power loss.
Draft, Insect, and Small Animal Immunity
The sealed optic chamber provides immunity to drafts
and insects, reducing false alarms. Small animal
immunity reduces false alarms caused by animals such
as rodents.
Remote Self Test
A remote self test initiates when the walk test input
switches to its true state. The alarm relay and alarm LED
activate for four seconds following a successful test. The
trouble relay activates, and the alarm LED flashes
following a failed test.
Input Power Supervision
When the power is lower than 8 V, a low input power
trouble condition activates the trouble relay and causes
the LED to flash. The trouble condition clears
automatically when power reaches or exceeds 8 V.
Professional Series Dual Detectors ISC-PDL1-W18G and ISC-PDL1-W18H | 3
Installation/Configuration Notes
Selectable Short-range Coverage 7.5 m x 10 m
(25 ft x 33 ft)
Mounting Considerations
The recommended mounting height is 2 m to 3 m (7 ft to
10 ft).
Use an optional B328 Gimbal-mount Bracket or B335-3
Low-profile Swivel-mount Bracket to surface-mount the
detector on a flat wall.
Use an optional B338 Universal Ceiling Bracket to mount
the detector on the ceiling.
Long-range Coverage 18 m x 25 m (60 ft x 80 ft)
4 | Professional Series Dual Detectors ISC-PDL1-W18G and ISC-PDL1-W18H
Technical Specifications
Ordering Information
ISC-PDL1-W18G PIR Microwave Detector
Enclosure Design
Indoor PIR 10.525 GHz microwave commercial
Color:
White
Dimensions:
136 mm x 69 mm x 58 mm
(5.25 in. x 2.75 in. x 2.25 in.)
High-impact ABS plastic
Material:
ISC-PDL1-W18G
detector. Provides tri-focus optics, sensor data fusion,
18 m x 25 m (60 ft x 80 ft) coverage, and LEDs in blue,
yellow, and red.
ISC-PDL1-W18H PIR Microwave Detector
ISC-PDL1-W18H
Indoor PIR 10.588 GHz microwave commercial
Environmental Considerations
detector. Provides tri-focus optics, sensor data fusion,
18 m x 25 m (60 ft x 80 ft) coverage, and LEDs in blue,
Relative Humidity:
Temperature (Operating and
0 to 95%, non-condensing
-29°C to +55°C (-20°F to +130°F)
Storage):
For UL Certificated installations, 0°C to +49°C
(+32°F to +120°F)
Environmental Class II
IP Rating:
IP 41, IK02 (EN60529, EN50102)
PIR Alarm Indicator:
Blue LED
Yellow LED
Red LED
Plastic swivel bracket for ceilings. The vertical pivot
range is +7° to -16°; the horizontal pivot range is ±45°.
86
Radio Frequency Interference
No alarm or setup on critical frequencies in
(RFI) immunity:
ISC-PDL1-W18G Microwave
the range from 26 MHz to 1 GHz at 50 V/m.
10.525 GHz
Frequency:
ISC-PDL1-W18H Microwave
10.588 GHz
Frequency:
Outputs
Solid state relay, normally-closed (NC)
contacts power supervised.
3 W, 125 mA, 25 VDC, resistance < 10 ohm
Tamper:
Normally-closed (NC) contacts (with cover
on) rated at 25 VDC, 125 mA maximum.
Connect tamper circuit to 24-hour protection
circuit.
Trouble:
Solid state relay normally-closed (NC)
contacts
Power Requirements
Voltage (Operating):
Current (Maximum):
9 VDC to 15 VDC
< 25 mA
Current (Standby):
Up to 13 mA
Europe, Middle East, Africa:
Bosch Security Systems B.V.
P.O. Box 80002
5600 JB Eindhoven, The
Netherlands
Phone:+31 (0) 40 27 83955
Fax:+31 (0) 40 27 86668
emea.securitysystems@bosch.com
http://www.boschsecurity.com
Americas:
Bosch Security Systems
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone:+1 585 223 4060
Fax:+1 800 289 0096
security.sales@us.bosch.com
http://www.boschsecurity.us
B335-3
range is ±25°. Shipped in packages of three.
B338 Universal Ceiling Bracket
Frequency Information
Relay:
B328
Plastic, swivel, low profile bracket for walls. The
vertical pivot range is +10° to -20°; the horizontal pivot
Number of…
Zones:
B328 Gimbal-mount Bracket
Mounts on a single-gang box and allows rotation of a
detector. Wires are hidden inside.
B335-3 Low-profile Swivel-mount Bracket
Indicators
Dual Alarm Indicator:
Microwave Alarm Indicator:
yellow, and red.
Accessories
Asia-Pacific:
Bosch Security Systems Pte Ltd
38C Jalan Pemimpin
Singapore 577180
Phone:+65 6319 3450
Fax:+65 6319 3499
apr.securitysystems@bosch.com
http://www.boschsecurity.com
© Bosch Security Systems 2006 | Data subject to change without notice F2761892363 | Cur: en-US, V3, 24 May 2006